Capistrano TR 31910 BCPR2021-0038 - Master Solar PlansADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL AARON HICKSON 10/27/2021 10/27/2021 SENT REQUESTING DOCUMENTS FOR REVIEW EMAIL JAKE FUSON 11/29/2021 11/29/2021 NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL. 2ND PC SUBMITTAL RECEIVED JAKE FUSON 12/7/2021 12/7/2021 EMAIL JAKE FUSON 1/11/2022 1/11/2022 NOTIFIED APPLICANT OF 2ND REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL. Description: CAPISTRANO / SOLAR MASTER PLANS - 2019 CODE CYCLE Status: APPROVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB)Status Date: Subtype: TRACT RESIDENTIAL Applied: 10/26/2021 Address: 57001 MONROE ST Approved: 3/10/2022 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: JAKE FUSON Expired: Details: CAPISTRANO / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 2X, 3, 3X & 4 FOR THE 2019 CODE CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING CODES. PLAN 1: 5.6kW SOLAR ARRAY - (16) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [320SF] PLAN 2, 2X, 3, 3X, 4: 7.0kW SOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350- BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [400SF] REVISION 1 - REVISED ROOF ATTACHMENT (STANCHION 6 TO QUICKHOOK). REVISION 2 - MODULE MODEL CHANGED, SYSTEM SIZES UPDATED. Printed: Wednesday, December 20, 2023 12:15:29 PM 1 of 5 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0038 CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT SHELLIE GEROME 25323 ALESSANDRO BLVD MORENO VALLEY CA 92553 (510)540-0550 Schellin.Gerome@Sunp owercorp.com CONTRACTOR SUNPOWER CORPORATION SYSTEMS 1414 HARBOUR WAY SOUTH #1901 RICHMOND CA 94804 (510)540-0550 Mason.litvinoff@sunpo wercorp.com OWNER DR HORTON 2280 Wardlow Circle, Suite 100 CORONA CA 92210 (510)540-0550 Schellin.Gerome@Sunp owercorp.com PRIMARY CONTACT Schellin Georme 25323 Alessandro blvd #1034 Moreno Valley CA 92553 (510)540-0550 Schellin.Gerome@Sunp owercorp.com 3RD PC SUBMITTAL RECEIVED JAKE FUSON 1/31/2022 1/31/2022 EMAIL JAKE FUSON 3/10/2022 3/10/2022 NOTIFIED APPLICANT THAT MASTER PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. EMAIL JAKE FUSON 5/12/2022 5/12/2022 NOTIFIED APPLICANT THAT REVISION 1 PLAN SHEETS HAVE BEEN APPROVED AND FEE IS READY FOR PAYMENT. EMAIL JAKE FUSON 7/19/2023 7/19/2023 NOTIFIED APPLICANT THAT REVISION 2 IS APPROVED AND READY FOR FEE PAYMENT. CONDITIONS FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 4 $644.00 $644.00 3/14/22 WEB11001 635953471 56 CREDIT 890895 ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 5/13/22 WEB11725 637143243 36 CREDIT 890895 ECON HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1 $161.00 $0.00 Total Paid for BUILDING STAFF - PER HOUR: $885.50 $724.50 Printed: Wednesday, December 20, 2023 12:15:29 PM 2 of 5 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0038 BOND INFORMATION INSPECTIONS INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES REVIEWS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD BY RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 12/9/21 WEB10109 634132127 33 CREDIT 890895 ECON Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 12/9/21 WEB10109 634132127 33 CREDIT 890895 ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS:$911.50 $750.50 REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG (1WK)JAKE FUSON 10/26/2021 11/2/2021 11/29/2021 REVISIONS REQUIRED SEE ATTACHED 1ST REVIEW CORRECTION LIST. 1ST BLDG (1WK)JAKE FUSON 4/1/2022 4/8/2022 5/12/2022 APPROVED REVISION 1 REVISION 1 - REVISED ROOF ATTACHMENT (STANCHION 6 TO QUICKHOOK). 1ST BLDG (1WK)JAKE FUSON 5/3/2023 5/17/2023 7/19/2023 APPROVED REVISION 2 REVISION 2 - MODULE MODEL CHANGED, SYSTEM SIZES UPDATED. 1ST PERMIT TECHNICIAN (1DAY) AARON HICKSON 10/26/2021 10/27/2021 10/29/2021 COMPLETE 2ND BLDG (1WK)JAKE FUSON 12/7/2021 12/14/2021 1/11/2022 REVISIONS REQUIRED SEE ATTACHED 2ND REVIEW CORRECTION LIST. 3RD BLDG (1WK)JAKE FUSON 1/31/2022 2/7/2022 3/10/2022 APPROVED Printed: Wednesday, December 20, 2023 12:15:29 PM 3 of 5 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0038 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/6/2022 AJ ORTEGA TAKEOFF SHEETS (UPDATED) BCPR2021-0038 - TAKEOFF SHEETS (UPDATED).pdf 0 DOC 10/27/2021 Etrakit Contractor 1ST SUBMITTAL MASTER PV PLAN The Enclave at Capistrano_C002279 - MPermit(1).pdf 1 DOC 12/6/2021 Etrakit Contractor 2ND SUBMITTAL - PV MASTER PLAN The Enclave at Capistrano_C002279 - MPermit_Revision.pdf 1 DOC 12/6/2021 Etrakit Contractor 2ND SUBMITTAL - RESUBMIT LETTER C002279 - MPermit Response Letter.pdf 1 DOC 1/31/2022 Etrakit Contractor 3RD SUBMITTAL SOLAR PLANS The Enclave at Capistrano_V3_C002279 - MPermit.pdf 1 DOC 1/31/2022 Etrakit Contractor 3RD SUBMITTAL RESPONSE LETTER C002279 - MPermit Response Letter_V2.pdf 1 DOC 2/15/2022 Etrakit Contractor 3RD SUBMITTAL RESPONSE LETTER (UPDATED) The Enclave at Capistrano_C002279 - MPPP -Resubmittal Letter V3.pdf 1 DOC 2/15/2022 Etrakit Contractor 3RD SUBMITTAL MASTER SOLAR PLANS (UPDATED) The Enclave at Capistrano_C002279 - MPPP_V4.pdf 1 DOC 3/31/2022 Etrakit Contractor REVISION 1 - 1ST SUBMITTAL PLAN The Enclave at Capistrano_C002279 - MPermit_V5.pdf 1 DOC 3/31/2022 Etrakit Contractor REVISION 1 - 1ST SUBMITTAL NARRATIVE C002279 - MPPP - Resubmittal Letter_V4.pdf 1 Printed: Wednesday, December 20, 2023 12:15:29 PM 4 of 5 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0038 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 5/3/2023 Etrakit Contractor REVISION 2 - 1ST SUBMITTAL MASTER PLANS The Enclave at Capistrano - MPPP 405.pdf 1 DOC 5/3/2023 Etrakit Contractor REVISION 2 - 1ST SUBMITTAL NARRATIVE OF CHANGES The Enclave at Capistrano - MPPP 405 - Resubmittal Letter.pdf 1 DOC 11/29/2021 JAKE FUSON 1ST REVIEW CORRECTION LIST BCPR2021-0038 - 1ST REVIEW CORRECTION LIST.pdf 1 DOC 1/11/2022 JAKE FUSON 2ND REVIEW CORRECTION LIST BCPR2021-0038 - 2ND REVIEW CORRECTION LIST.pdf 1 DOC 3/10/2022 JAKE FUSON TAKEOFF SHEETS (DO NOT USE) BCPR2021-0038 - TAKEOFF SHEETS.pdf 0 DOC 3/10/2022 JAKE FUSON MASTER SOLAR PLANS (APPROVED) BCPR2021-0038 - MASTER SOLAR PLANS (APPROVED).pdf 1 DOC 5/12/2022 JAKE FUSON REVISION 1 - PLAN SHEETS (APPROVED) BCPR2021-0038 - REVISION 1 - PLAN SHEETS (APPROVED).pdf 1 DOC 11/7/2022 JAKE FUSON RFI - UPDATED DESIGN FOR ATTIC-ROOF TRANSITION RFI - UPDATED DESIGN FOR ATTIC-ROOF TRANSITION.pdf 1 DOC 7/19/2023 JAKE FUSON REVISION 2 - PLAN SHEETS (APPROVED) BCPR2021-0038 - REVISION 2 - PLAN SHEETS (APPROVED).pdf 1 Printed: Wednesday, December 20, 2023 12:15:29 PM 5 of 5 Project Details City of La Quinta PROJECT NUMBER BCPR2021-0038 BCPR2021-0038 – CAPISTRANO MASTER SOLAR PLAN TAKE-OFFS PLAN 1 Permit Notes: 5.6kW SOLAR ARRAY - (16) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [320SF] REFERENCE BCPR2021-0038 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES. Description: CAPISTRANO / 5.6kW PV SYSTEM - (16) 350W AC PANELS/100A PV SUB Fee Breakdown: - Building Standards Administration (BSAS) - Electrical PV System less than 10kW PC - PV System less than 10kW o Miscellaneous Electrical Equipment PC x 0 (PV COMBINER PANEL ONLY) o Miscellaneous Electrical Equipment x 0 (PV COMBINER PANEL ONLY) - Permit issuance - Records Management Fee - Technology Enhancement Fee PLAN 2, 2X, 3, 3X, & 4 Permit Notes: 7.0kWSOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [400SF] REFERENCE BCPR2021-0038 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES. Description: CAPISTRANO / 7.0kW PV SYSTEM – (20) 350W AC PANELS/100A PV SUB Fee Breakdown: - Building Standards Administration (BSAS) - Electrical PV System less than 10kW PC - PV System less than 10kW o Miscellaneous Electrical Equipment PC x 0 (PV COMBINER PANEL ONLY) o Miscellaneous Electrical Equipment x 0 (PV COMBINER PANEL ONLY) - Permit issuance - Records Management Fee - Technology Enhancement Fee BCPR2021-0014 – CAPISTRANO MASTER SOLAR PLAN TAKE-OFFS PLAN 1 Permit Notes: PLAN 1: 5.6kW SOLAR ARRAY - (16) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [320SF] REFERENCE BCPR2021-0038 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment PC x 1 o Miscellaneous Electrical Equipment x 1 - Permit issuance - Records Management Fee - Technology Enhancement Fee PLAN 2, 2X, 3, 3X, & 4 Permit Notes: PLAN 2, 2X, 3, 3X, 4: 7.0kWSOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [400SF] REFERENCE BCPR2021-0038 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES. Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW o Miscellaneous Electrical Equipment PC x 1 o Miscellaneous Electrical Equipment x 1 - Permit issuance - Records Management Fee - Technology Enhancement Fee CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S T ATEOF CA L I F O R NIA &+,)81*/ ( 81 * TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H o r t o n - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C O R O N A C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119300 2022-02-10 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 VICINITY MAP SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-0 GENERAL NOTES: SHEET INDEX SOLAR STRUCTURAL DRAWINGS PVS-1 MOUNTING DETAILS & STRUCTURAL CALCULATIONS SOLAR MASTER PLAN PERMIT PACKAGE DR HORTON - SOCAL - INLAND/CORONA 2280 WARDLOW CIRCLE STE 100 CORONA, CA 92878 5.60 KW & 7.00 KW PHOTOVOLTAIC SYSTEM TRACT/PARCEL #: 31910LA QUINTA, CALIFORNIA 92210 THE ENCLAVE AT CAPISTRANO PLAN 1 (2348), 2 (2529), 2X (2738), 3 (2679), 3X (2911), 4 (3003) PROJECT LOCATION $//&216758&7,216+$//&203/<:,7+7+(&$/,)251,$%8,/',1*5(6,'(17,$/0(&+$1,&$/ (/(&75,&$/3/80%,1*(1(5*<$1'*5((1%8,/',1*&2'(6$1'7+(/$48,17$081,&,3$/&2'( SOLAR ARCHITECTURAL DRAWINGS PVA-0 PVA-1 PVA-2 PVA-3 PVA-4 PVA-5 PVA-6 COVER SHEET PLAN 1 (2348) ELEVATION A, B, C PLAN 2 (2529) ELEVATION A, B, C PLAN 2X (2738) ELEVATION A, B, C PLAN 3 (2679) ELEVATION A, B, C PLAN 3X (2911) ELEVATION A, B, C PLAN 4 (3003) ELEVATION A, B, C SOLAR ELECTRICAL DRAWINGS PVE-1.1 PVE-2 PVE-3 ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM ELECTRICAL DETAILS ELECTRICAL DATA & SPECIFICATIONS PVE-1.2 PVE-1.3 PVE-1.4 PVE-1.5 PVE-1.6 BCPR2021-0038 THE ENCLAVE AT CAPISTRANO / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 2X, 3, 3X & 4 FOR THE 2019 CODE CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING CODES. PLAN 1: 5.6kW SOLAR ARRAY - (16) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [320SF] PLAN 2, 2X, 3, 3X, 4: 7.0kW SOLAR ARRAY - (20) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [400SF] 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 16 5.60 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2348 SQ. FT. FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 FRONT OF HOUSE : 330° - 0°LAYOUT 4 FRONT OF HOUSE : 60° - 90°LAYOUT 5 FRONT OF HOUSE : 240° - 270°LAYOUT 6 PLAN 1 (2348) - ELEVATION A (SPANISH) - S-TILE PLAN 1 (2348) - ELEVATION B (TUSCAN) - S-TILE PLAN 1 (2348) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 FRONT OF HOUSE : 330° - 0°LAYOUT 4 FRONT OF HOUSE : 60° - 90°LAYOUT 5 FRONT OF HOUSE : 240° - 270°LAYOUT 6 FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINT SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAMTO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINTFRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAMTO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX ROOF ACCESS POINTFRONT OF HOUSE (FOH) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAMTO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINT SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAMTO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINTFRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) SEE PVE 1.1 FOR ELECTRICAL SINGLE DIAGRAMTO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINTROOF ACCESS POINT TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 1 ( 2 3 4 8 ) E L E V A T I O N A , B , A N D C PVA-1 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 20 7.00 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2529 SQ. FT. FRONT OF HOUSE : 150° - 270°FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 2 (2529) - ELEVATION A (SPANISH) - S-TILE PLAN 2 (2529) - ELEVATION B (TUSCAN) - S-TILE PLAN 2 (2529) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 150° - 270°FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 330° - 90°FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 TRANSITION BOX FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM FRONT OF HOUSE : 240° - 270°LAYOUT 4 TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) FRONT OF HOUSE : 150° - 180°LAYOUT 3 TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE : 330° - 0°LAYOUT 4 FRONT OF HOUSE : 60° - 90°LAYOUT 5 FRONT OF HOUSE : 240° - 270°LAYOUT 6 TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT TRANSITION BOX (TYP.) FRONT OF HOUSE : 150° - 180°LAYOUT 3 TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE : 330° - 0°LAYOUT 4 FRONT OF HOUSE : 60° - 90°LAYOUT 5 FRONT OF HOUSE : 240° - 270°LAYOUT 6 TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT TRANSITION BOX (TYP.) LAYOUT 1 ROOF ACCESS POINT ROOF ACCESS POINT LAYOUT 1 LAYOUT 1 ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 2 ( 2 5 2 9 ) E L E V A T I O N A , B , A N D C PVA-2 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 20 7.00 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2738 SQ. FT. FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 2X (2738) - ELEVATION A (SPANISH) - S-TILE PLAN 2X (2738) - ELEVATION B (TUSCAN) - S-TILE PLAN 2X (2738) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 FRONT OF HOUSE : 240° - 270°LAYOUT 4 TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.6 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.5 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 2 X ( 2 7 3 8 ) E L E V A T I O N A , B , A N D C PVA-3 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 20 7.00 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2679 SQ. FT. FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 PLAN 3 (2679) - ELEVATION A (SPANISH) - S-TILE PLAN 3 (2679) - ELEVATION B (TUSCAN) - S-TILE PLAN 3 (2679) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3 FRONT OF HOUSE : 60° - 90°LAYOUT 4 TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.6 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.6 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.)FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) ROOF ACCESS POINT TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 3 ( 2 6 7 9 ) E L E V A T I O N A , B , A N D C PVA-4 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 20 7.00 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2911 SQ. FT. FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 0°LAYOUT 2 PLAN 3X (2911) - ELEVATION A (SPANISH) - S-TILE PLAN 3X (2911) - ELEVATION B (TUSCAN) - S-TILE PLAN 3X (2911) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 0°LAYOUT 2 FRONT OF HOUSE : 60° - 90°LAYOUT 3 FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 FRONT OF HOUSE : 330° - 0°LAYOUT 4 FRONT OF HOUSE : 60° - 90°LAYOUT 5 FRONT OF HOUSE : 240° - 270°LAYOUT 6 TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM FRONT OF HOUSE : 60° - 90°LAYOUT 3 TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.5 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.5 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.6 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.6 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT (N) LOAD CENTER (INSIDE GARAGE) TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 3 X ( 2 9 1 1 ) E L E V A T I O N A , B , A N D C PVA-5 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- SUNPOWER 96 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 350W SYSTEM SIZE SPR-X21-350-BLK-E-AC QUANTITY: 20 7.00 kW NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 3003 SQ. FT. FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 150° - 180°LAYOUT 2 FRONT OF HOUSE : 60° - 90°LAYOUT 3 PLAN 4 (3003) - ELEVATION A (SPANISH) - S-TILE PLAN 4 (3003) - ELEVATION B (TUSCAN) - S-TILE PLAN 4 (3003) - ELEVATION C (MEDITERRANEAN) - S-TILE FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 150° - 180°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3 FRONT OF HOUSE : 60° - 90°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5 FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.)ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.5 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX (TYP.)ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.5 FOR ELECTRICAL SINGLE DIAGRAM FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) TRANSITION BOX (TYP.) SEE PVE 1.3 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM SEE PVE 1.4 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM TRANSITION BOX FRONT OF HOUSE (FOH) TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) SEE PVE 1.2 FOR ELECTRICAL SINGLE DIAGRAM ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TH E E N C L A V E A T C A P I S T R A N O TR A C T N O . 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A 9 2 2 1 0 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119299 02/10/2022 COLEEN ABRENICA SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 PL A N 4 ( 3 0 0 3 ) E L E V A T I O N A , B , A N D C PVA-6 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H o r t o n - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C O R O N A C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119300 2022-02-10 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-1 RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A 03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 5.60 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 30A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 8 AC MODULESBRANCH CIRCUIT #2 8 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 8 VOLTAGE 240 V BRANCH CURRENT: IOUT = 10.48 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.76% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 13.10 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 8 VOLTAGE 240 V BRANCH CURRENT: IOUT = 10.48 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.76% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 13.10 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #10 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 20.96 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 26.20 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 25.56 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.22% OVERCURRENT PROTECTION 30A, 2P MINIMUM OCPD = IOUT x 1.25 26.20 A OCPD SIZE 30 A VOLTAGE DROP AT 70 FT DISTANCE VOLTAGE DROP AT 70 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.1 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 '  COLIVA  EOR CO R O N A , C A 9 2 8 7 8  03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 5.60 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 30A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 6 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 10 VOLTAGE 240 V BRANCH CURRENT: IOUT = 13.10 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 16.38 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.59 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.41% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 16.38 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 6 VOLTAGE 240 V BRANCH CURRENT: IOUT = 7.86 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 9.83 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 13.55 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.65% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 9.83 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #10 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 20.96 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 26.20 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 25.56 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.22% OVERCURRENT PROTECTION 30A, 2P MINIMUM OCPD = IOUT x 1.25 26.20 A OCPD SIZE 30 A VOLTAGE DROP AT 30 FT DISTANCE VOLTAGE DROP AT 80 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.2 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNG L E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 D-0118694 01-14-2022 COLIVA 01-14-2022 EOR CO R O N A , C A 9 2 8 7 8 01-14-2022 03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 7.00 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 40A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11.IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 10 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 10 VOLTAGE 240 V BRANCH CURRENT: IOUT = 13.10 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 16.38 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.59 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 1.08% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 16.38 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 10 VOLTAGE 240 V BRANCH CURRENT: IOUT = 13.10 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 16.38 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.59 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 1.08% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 16.38 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #8 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 26.20 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 32.75 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 31.95 A WIRE SIZE SELECTED BASED ON AMPACITY #8 AMPACITY AT 60C TERMINATION (>IOUT) 40A CONDUCTOR SIZE PER NEC #8 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.27% OVERCURRENT PROTECTION 40A, 2P MINIMUM OCPD = IOUT x 1.25 32.75 A OCPD SIZE 40 A VOLTAGE DROP AT 80 FT DISTANCE VOLTAGE DROP AT 80 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1. E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 '  COLIVA  EOR CO R O N A , C A 9 2 8 7 8  03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 7.00 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 40A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B 9 AC MODULESBRANCH CIRCUIT #2 11 AC MODULESBRANCH CIRCUIT #1 SPR-X21-350-BLK-E-AC #10 #10 SPR-X21-350-BLK-E-AC (240) AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 11 VOLTAGE 240 V BRANCH CURRENT: IOUT = 14.41 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 18.01 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 24.84 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.74% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 18.01 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 9 VOLTAGE 240 V BRANCH CURRENT: IOUT = 11.79 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 14.74 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 20.33 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 1.10% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 14.74 OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #8 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 26.20 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 32.75 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 31.95 A WIRE SIZE SELECTED BASED ON AMPACITY #8 AMPACITY AT 60C TERMINATION (>IOUT) 40A CONDUCTOR SIZE PER NEC #8 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.27% OVERCURRENT PROTECTION 40A, 2P MINIMUM OCPD = IOUT x 1.25 32.75 A OCPD SIZE 40 A VOLTAGE DROP AT 50 FT DISTANCE VOLTAGE DROP AT 90 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.4 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNG L E UN G 01-14-2022 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 D-0118694 01-14-2022 COLIVA 01-14-2022 EOR CO R O N A , C A 9 2 8 7 8 03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 7 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 40A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE BRANCHCIRCUIT2 BRANCHCIRCUIT1 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #10 NUMBER OF MODULES PER BRANCH CIRCUIT 12 VOLTAGE 240 V BRANCH CURRENT: IOUT = 15.72 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 19.65 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 27.10 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.81% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 19.65 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER #10 NUMBER OF MODULES PER BRANCH CIRCUIT 8 VOLTAGE 240 V BRANCH CURRENT: IOUT = 10.48 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.76% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 13.10 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #8 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 26.20 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 32.75 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 31.95 A WIRE SIZE SELECTED BASED ON AMPACITY #8 AMPACITY AT 60C TERMINATION (>IOUT) 40A CONDUCTOR SIZE PER NEC #8 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10 0.27% OVERCURRENT PROTECTION 40A, 2P MINIMUM OCPD = IOUT x 1.25 32.75 A OCPD SIZE 40 A VOLTAGE DROP AT 50 FT DISTANCE VOLTAGE DROP AT 70 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER SPR-X21-350-BLK-E-AC 12 AC MODULES 8 AC MODULES #10 #10 F 1 2F NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B #10 #10 EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1.5 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNG L E UN G 01-14-2022 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 D-0118694 01-14-2022 COLIVA 01-14-2022 EOR CO R O N A , C A 9 2 8 7 8 03/10/2022 FIGURE A: SINGLE LINE DIAGRAM - 7 kWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER *MSP MAX PV BREAKER (A) = X 120% - =200A, 2P 40A, 2P 200A, 2P 200A, 2P 40A, 2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12.CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG SPR-X21-350-BLK-E-AC (240) LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE BRANCHCIRCUIT2 BRANCHCIRCUIT1 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B INTEGRATED MICROINVERTER B AC, BRANCH 1 FIGURE C: ELECTRICAL CALCULATIONS AC, BRANCH 2 AC, SUB-PANEL #8 NUMBER OF MODULES PER BRANCH CIRCUIT 12 VOLTAGE 240 V BRANCH CURRENT: IOUT = 15.72 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 19.65 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 27.10 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #8 0.87% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 19.65 A OCPD SIZE 20 A ROOF JCT BOX TO PV LOAD CENTER # NUMBER OF MODULES PER BRANCH CIRCUIT 8 VOLTAGE 240 V BRANCH CURRENT: IOUT = 10.48 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE ADDER 22°C TEMPERATURE USED FOR AMPACITY DE-RATING 69°C TEMPERATURE DE-RATING COEFFICIENT 0.58 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A WIRE SIZE SELECTED BASED ON AMPACITY #10 AMPACITY AT 60C TERMINATION (>IOUT) 30 A CONDUCTOR SIZE PER NEC #10 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP # 0.66% OVERCURRENT PROTECTION 20A, 2P MINIMUM OCPD = IOUT x 1.25 13.10 A OCPD SIZE 20 A PV LOAD CENTER TO GRID-TIE #8 VOLTAGE 240 V SUM OF BRANCHES: IOUT_TOTAL = 26.20 A MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 32.75 A CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE 47°C TEMPERATURE USED FOR AMPACITY DE-RATING 47°C TEMPERATURE DE-RATING COEFFICIENT 0.82 FILL DE-RATING COEFFICIENT 1 IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 31.95 A WIRE SIZE SELECTED BASED ON AMPACITY #8 AMPACITY AT 60C TERMINATION (>IOUT) 40A CONDUCTOR SIZE PER NEC #8 CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP # 0.27% OVERCURRENT PROTECTION 40A, 2P MINIMUM OCPD = IOUT x 1.25 32.75 A OCPD SIZE 40 A VOLTAGE DROP AT 85 FT DISTANCE VOLTAGE DROP AT 61 FT DISTANCE VOLTAGE DROP AT 10 FT DISTANCE ROOF JCT BOX TO PV LOAD CENTER SPR-X21-350-BLK-E-AC 12 AC MODULES 8 AC MODULES #8 #10 F 1 2F NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B #10 #10 EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B C B R E V I S I O N S NOT TO SCALE 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S C A L I C E N S E # : 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) PVE-1. E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA CHIFUNGL E UN G DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 '  COLIVA  EOR CO R O N A , C A 9 2 8 7 8  03/10/2022 FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION FIGURE 1: ELECTRICAL SIGNAGES/STICKERS WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE x x x TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM x x x E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S T ATEOF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H o r t o n - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C O R O N A C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119300 2022-02-10 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 x x x x x x PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: 20.96 240 20.96 240 26.20 240 26.20 240 5.6 KW 5.6 KW 7 KW 7 KW PHOTOVOLTAIC SYSTEM COMBINER PANEL: DO NOT ADD LOADS x AC SOLAR DISCONNECT x SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D E T A I L S PVE-2 RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: ADDRESS PHOTOVOLTAICARRAY ON ROOF SOLAR LOADCENTER PHOTOVOLTAIC AC DISCONNECT MAIN SERVICEPANEL DRIVEWAY TYPICAL DIRECTORY PLACARD NOTE: CUSTOMIZED PLACARD WILL BE PROVIDEDFOR EACH LOT(UNIT) 03/10/2022 AC DISCONNECT DATA SHEET CURRENT TRANSFORMER SPECIFICATION SHEET PV MODULE SPECIFICATION SHEET PG PVS6 DATASHEET 1 PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 2 PV MODULE COMPLIANCE LETTER CERTIFICATE OF COMPLIANCE FOR WIRING SYSTEM AND HARNESS CONDUCTOR AND OCP SIZING TABLE INVISIMOUNT DATA SHEET CERTIFICATE OF COMPLIANCE CLASS A FIRE RATING UL LISTING PG 1/3 CLASS A FIRE RATING UL LISTING PG 2/3 CLASS A FIRE RATING UL LISTING PG 3/3 PVS6 INSTALLATION INSTRUCTIONS 1 TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H o r t o n - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C O R O N A C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0119300 2022-02-10 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S T ATEOF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-3 RE V I S E D T O R E F L E C T C H A N G E I N I N S T A L L A T I O N T Y P E 2/ 1 0 / 2 2 C A SOLAR MASTER PLAN PERMIT PACKAGE DR HORTON - SO CAL - INLAND/CORONA 2280 WARDLOW CIRCLE, SUITE 100CORONA, CA 92878 TRACT / PARCEL #: 31910LAQUINTA, CALIFORNIA 92253 THE ENCLAVE AT CAPISTRANO PLAN 1 (2348), 2 (2529), 2X (2738), 3 (2679), 3X (2911), 4 (3003) 5.67 kW, 6.48 kW, 7.29 kW PHOTOVOLTAIC SYSTEM CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHIFUNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® VICINITY MAP SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-0 GENERAL NOTES: SHEET INDEX SOLAR ARCHITECTURAL DRAWINGS SOLAR STRUCTURAL DRAWINGS SOLAR ELECTRICAL DRAWINGS PVE-1.1 ELECTRICAL SINGLE LINE DIAGRAM PVE-2.2 PVE-3 MOUNTING DETAILSPVS-1 PVA-0 COVER SHEET PVA-1 PLAN 1 (2348) ELEVATION A,B,C PVA-2 PVA-3 PVA-4 PVA-5 PLAN 2 (2529) ELEVATION A,B,C PLAN 2X (2738) ELEVATION A,B,C PLAN 3 (2679) ELEVATION A,B,C PLAN 3X (2911) ELEVATION A,B,C PVA-6 PLAN 4 (3003) ELEVATION A,B,C PVE-1.2 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.3 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.4 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.5 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.6 ELECTRICAL SINGLE LINE DIAGRAM PVE-4 ELECTRICAL DETAILS ELECTRICAL DETAILS ELECTRICAL DATA & SPECIFICATIONS ELECTRICAL DATA & SPECIFICATIONS PROJECT LOCATION PVE-2.1 REVISION #2 BCPR2021-0038 MODULE MODEL CHANGED, SYSTEM SIZES UPDATED 07/19/2023 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 1 (2348) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2348 SQ. FT. SLD REFERENCE PVE-1.1 SUNPOWER 132 CELLS AC MODULES QUANTITY: 14 MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE 5.67 kWQ.PEAK DUO BLK ML-G10+ (405) SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.2 SLD REFERENCE PVE-1.2 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 PLAN 1 (2348) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.2 SLD REFERENCE PVE-1.2 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 PLAN 1 (2348) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 LAYOUT 1 LAYOUT 2 LAYOUT 3 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120°LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° BACK FRONT OF HOUSE : 285° - 120°LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT TRANSITION BOX (TYP.) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-1 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 1 ( 2 3 4 8 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 2 (2529) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2529 SQ. FT. SLD REFERENCE PVE-1.3 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 16 6.48 kW SLD REFERENCE PVE-1.3 LAYOUT 1 LAYOUT 2 PLAN 2 (2529) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 LAYOUT 1 LAYOUT 2 PLAN 2 (2529) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 LAYOUT 1 LAYOUT 2 LAYOUT 3 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-2 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 2 ( 2 5 2 9 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 2X (2738) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2738 SQ. FT. SLD REFERENCE PVE-1.5 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 18 7.29 kW SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 PLAN 2X (2738) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 PLAN 2X (2738) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 LAYOUT 3 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-3 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 2 X ( 2 7 3 8 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 3 (2679) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2679 SQ. FT. SLD REFERENCE PVE-1.3 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 16 6.48 kW SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 PLAN 3 (2679) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 PLAN 3 (2679) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 LAYOUT 1 LAYOUT 2 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° LEFT FRONT OF HOUSE : 15° - 210° BACK FRONT OF HOUSE : 285° - 120°LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° BACK FRONT OF HOUSE : 285° - 120°LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) TRANSITION BOX (TYP.)TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-4 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 3 ( 2 6 7 9 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 3X (2911) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2911 SQ. FT. SLD REFERENCE PVE-1.5 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 18 7.29 kW SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 LAYOUT 3 PLAN 3X (2911) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 LAYOUT 3 PLAN 3X (2911) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 LAYOUT 3 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° RIGHT FRONT OF HOUSE : 195° - 30°FRONT OF HOUSE : 15° - 120°BACK & LEFT RIGHT FRONT OF HOUSE : 195° - 30°FRONT OF HOUSE : 15° - 120°BACK & LEFT LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® PVA-5 SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PL A N 3 X ( 2 9 1 1 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- PLAN 4 (3003) - ELEVATION A (SPANISH) - S-TILE NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 3003 SQ. FT. SLD REFERENCE PVE-1.6 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 18 7.29 kW SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 PLAN 4 (3003) - ELEVATION B (TUSCAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 PLAN 4 (3003) - ELEVATION C (MEDITERRANEAN) - S-TILE SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 LAYOUT 1 LAYOUT 2 LAYOUT 3 FRONT FRONT OF HOUSE : 105° - 300° FRONT FRONT OF HOUSE : 105° - 300° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° BACK FRONT OF HOUSE : 285° - 120° LEFT FRONT OF HOUSE : 15° - 210°RIGHT FRONT OF HOUSE : 195° - 30° FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (TYP.) ROOF ACCESS POINT (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT TRANSITION BOX (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATE OF CA L I F O R NIA TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-6 PL A N 4 ( 3 0 0 3 ) E L E V A T I O N A , B & C TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 3 / 8 / 2 3 R A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 5.67 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 30A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 7 AC MODULESBRANCH CIRCUIT #2 7 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.1 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 5.67 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 30A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 5 AC MODULESBRANCH CIRCUIT #2 9 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.2 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 6.48 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 8 AC MODULESBRANCH CIRCUIT #2 8 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.3 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 6.48 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 6 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.4 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 7.29 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 9 AC MODULESBRANCH CIRCUIT #2 9 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.5 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE A: SINGLE LINE DIAGRAM - 7.29 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC EATON DG222URB OR EQUIVALENT #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 8 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #8 IQ7HS-66-M-US (240) ATTIC ROOFTOP *MSP MAX PV BREAKER (A) = 200A, 2P X 120% - 200A, 2P = 40A, 2P MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-25R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E , S U I T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 CO R O N A , C A 9 2 8 7 8 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002279 D-0126001 2023-04-07 COLEEN ABRENICA TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.6 TR A N S I T I O N T O 4 0 5 W H A N W H A Q - C E L L 4 / 7 / 2 3 C A 07/19/2023 REVISION #2 FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION EL E C T R I C A L D E T A I L S SHEET RE V DE S C R I P T I O N DA T E DB CB R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C A L I C E N S E # 8 9 0 8 9 5 SP R - X 2 1 - 3 5 0 - B L K - E - A C ( 2 4 0 ) DETAIL CH I F U N G LE U N G E LECT R I C A L E22659 Exp. 03-31-23 R EGISTER E D P R O F ESSIONA L E N G I N EER S T A TE OF CA L I F O R N IA FI L E : D - 0 1 1 6 4 2 3 - M P P P - 1 0 0 5 2 0 2 1 - S O L A R - P V E - 3 . d w g , U S E R : n l i v e l y , D A T E / T I M E : N o v 0 4 , 2 0 2 2 - 1 : 2 3 p m DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID CHECKED BY DATE CHECKED TH E E N C L A V E A T C A P I S T R A N O TR A C T / P A R C E L # : 3 1 9 1 0 DR H O R T O N - S O C A L - I N L A N D / C O R O N A 22 8 0 W A R D L O W C I R C L E S T E 1 0 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 1 0 C002279 D-0116423 11-04-2022 LIVELY 10-05-2021 EOR CO R O N A , C A 9 2 8 7 8 11-04-2022