Loading...
PGA West - Coral Mountain TR 34243 BCPR2021-0008 - Title 24CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 GENERAL INFORMATION 01 Project Name Plan D MOD 02 Run Title Title 24 Analysis 03 Project Location Coral Mountain (Escena) 04 City La Quinta, CA 05 Standards Version 2019 06 Zip code 92210 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)AllOrientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.36 18 Total Cond. Floor Area (ft 2)2863 19 Glazing Percentage (%)21.32% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. BCPR2021-0008 CORAL MOUNTAIN PLAN D-MOD TRACT CONSTRUCTION PLANS 07/20/2021 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 ENERGY DESIGN RATING Energy Design Ratings Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 45 21 Proposed Designs North Facing 42.4 20.3 2.6 0.7 East Facing 42.3 20.2 2.7 0.8 South Facing 43.1 21 1.9 0 West Facing 41.7 19.6 3.3 1.4 RESULT:3:COMPLIES ¹ Efficiency EDR includes improvements to the building envelope and more efficient equipment ² Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries ³ Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 5.37 kWdc 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.41 2.14 -0.73 -51.8 Space Cooling 75.49 67.4 8.09 10.7 IAQ Ventilation 2.28 2.28 0 0 Water Heating 6.99 6.99 0 0 Self Utilization Credit n/a 0 0 n/a North Facing Compliance Total 86.17 78.81 7.36 8.5 Space Heating 1.41 2.11 -0.7 -49.6 Space Cooling 75.49 67.18 8.31 11 IAQ Ventilation 2.28 2.28 0 0 Water Heating 6.99 6.99 0 0 Self Utilization Credit n/a 0 0 n/a East Facing Compliance Total 86.17 78.56 7.61 8.8 Space Heating 1.41 2.44 -1.03 -73 Space Cooling 75.49 69.06 6.43 8.5 IAQ Ventilation 2.28 2.28 0 0 Water Heating 6.99 6.99 0 0 Self Utilization Credit n/a 0 0 n/a South Facing Compliance Total 86.17 80.77 5.4 6.3 Space Heating 1.41 2.36 -0.95 -67.4 Space Cooling 75.49 65.21 10.28 13.6 IAQ Ventilation 2.28 2.28 0 0 Water Heating 6.99 6.99 0 0 Self Utilization Credit n/a 0 0 n/a West Facing Compliance Total 86.17 76.84 9.33 10.8 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg)Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 5.35 NA Premium Fixed (roof mount)Microinverters true 105-300 n/a n/a <=7:12 97.5 97 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation above roof deck •Insulation below roof deck HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan D MOD 2863 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Home Conditioned HVAC1 2863 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall Home R-19+R-4 Wall.0 Front 546.6 130 90 Left Exterior Wall Home R-19+R-4 Wall.90 Left 300.8 205.8 90 Rear Exterior Wall Home R-19+R-4 Wall.180 Back 590 152 90 Right Exterior Wall Home R-19+R-4 Wall.270 Right 521.7 146.64 90 North Interior Surface Home>>__Garage__R-19 Wall n/a n/a 43.3 0 n/a Right Interior Surface Home>>__Garage__R-19 Wall n/a n/a 220.8 24 n/a Roof Home R-0+R-30 BD w/R-5.7 AD n/a n/a 2863 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 497 n/a n/a Front Exterior Wall 2 __Garage__R-0 Wall 0 Front 235 21.3 90 Left Exterior Wall 2 __Garage__R-0 Wall 90 Left 220.8 128 90 Right Exterior Wall 2 __Garage__R-0 Wall 270 Right 191.7 0 90 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 1 0.66 0.95 No No Attic Home Attic RoofHome Unventilated 1 0.66 0.95 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading OP - 111A - (4056)Window Front Exterior Wall Front 0 1 22 0.29 NFRC 0.21 NFRC Bug Screen OP - 112A - (4056)Window Front Exterior Wall Front 0 1 22 0.29 NFRC 0.21 NFRC Bug Screen OP - 118A - (4056)Window Front Exterior Wall Front 0 1 22 0.29 NFRC 0.21 NFRC Bug Screen FX - 104A (410)Window Front Exterior Wall Front 0 1 40 0.31 NFRC 0.24 NFRC Bug Screen SGD - 104.1 Window Left Exterior Wall Left 90 1 205.8 0.41 NFRC 0.22 NFRC Bug Screen FX - 104B (410)Window Rear Exterior Wall Back 180 1 40 0.31 NFRC 0.24 NFRC Bug Screen FX - 108A (4080)Window Rear Exterior Wall Back 180 1 32 0.31 NFRC 0.24 NFRC Bug Screen SGD - 105.1 Window Rear Exterior Wall Back 180 1 80 0.41 NFRC 0.22 NFRC Bug Screen FX - 109B (3080)Window Right Exterior Wall Right 270 1 24 0.27 NFRC 0.22 NFRC Bug Screen FX - 109A (3080)Window Right Exterior Wall Right 270 1 24 0.27 NFRC 0.22 NFRC Bug Screen FX - 108B (4480)Window Right Exterior Wall Right 270 1 34.64 0.31 NFRC 0.24 NFRC Bug Screen SGD - 108.2 (8080)Window Right Exterior Wall Right 270 1 64 0.41 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 24 0.2 Door 2 Right Interior Surface 24 0.2 Door 3 Front Exterior Wall 2 21.3 0.2 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door 4 Left Exterior Wall 2 128 0.2 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2863 196 None 80%No Slab-on-Grade 2 __Garage__497 65 None 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-19+R-4 Wall.Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-19 None / R-4 0.055 Inside Finish: Gypsum Board Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco R-19 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-19 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-19 in 5-1/2 in. (R-18) / 2x6 Other Side Finish: Gypsum Board 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.644 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofHome Attic Roofs Wood Framed Ceiling 2x6 @ 24 in. O. C.R-30 None / R-5.7 0.028 Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-5.7 Sheathing Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-20.4 / 2x6 Under Roof Joists: R-9.6 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-30 BD w/R-5.7 AD Ceilings (below attic) Wood Framed Ceiling 2x6 @ 24 in. O. C.R-0 None / None 0.478 Cavity / Frame: no insul. / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (1)n/a None n/a 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff. 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 1 0 0.81-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC1 Heating and cooling system other Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 2 2 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 2 AFUE-95 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER Efficiency SEER Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 2 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 111 0.25 Default 0 n/a 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Plan D MOD Calculation Date/Time:2021-06-23T07:45:19-07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:Alta Verde La Quinta Plan D MOD.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Schema Version: rev 20200101 Report Generated: 2021-06-23   07:47:25 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Cristela Lujan Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2021-06-24 13:05:48 R16-18-20136 702-365-8080 Russell Jones Alta Verde Builders 71905 Hwy 111, Ste G Rancho Mirage, CA 92270 2021-06-24 18:09:07 N/A 760-776-1111 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010080671D-000-000-0000000-0000 2021-06-24 18:09:07 CalCERTS inc.