Loading...
BCOM2021-0083BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address APN: Legal Description Property Zoning: Valuation: PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 08/16/2021 ISSUED DATE: 10/27/2021 CALIFORNIA Building Commercial Owner: OLD TOWN LA QUINTA LLC BCOM2021-0083 78010 MAIN ST NO 201, LA QUINTA, CA 92253 78065 MAIN ST STE 101 Applicant: Todd Webber 770121012 78065 Main St. #C101, La Quinta, CA 92253 Contractor: SUTTON REMODELING SPECIALISTS DBA SRS-BU 41905 BOARDWALK STE I, PALM DESERT, CA $250,000.00 92211 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.Ieginfo.ca.gov/calaw.htm1. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 5/13/25 4:14 pm Page 1 of 5 BUILDING PERMIT Permit Type: Building Commercial Permit Number: BCOM2021-0083 Property Address: 78065 MAIN ST STE 101 application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 5/13/25 4:14 pm Page 2 of 5 BUILDING PERMIT Permit Type: Building Commercial Permit Number: BCOM2021-0083 Property Address: 78065 MAIN ST STE 101 SOTHEBY'S / 1,595 REAL ESTATE OFFICE TENANT IMPROVEMENT *** SOTHEBY'S / 1,595SF REAL ESTATE OFFICE TENANT IMPROVEMENT [VB/B-OCC/11-OL/SPRINKLED] NO TUMF ASSESSMENT PER 2018 HANDBOOK. PATH OF TRAVEL IS IN FULL COMPLIANCE PER ARCHITECT --VERIFY IN FIELD. THIS PERMIT DOES NOT INCLUDE REVIEW FOR CHANGE OF USE OR ALLOWABL AREA ANALYSIS. 2019 CALIFORNIA BUILDING CODES. ,instruction Det;:. Commercial Work Type Remodel Building/Unit B: Office, Professional Conditioned Square 1595 Occupancy Footage Classification(s) Occupant Load 11 Construction Type V-B Code Edition 2019 Remodel Area Square 1595 New Electrical Square 1595 Number of Air 1 Footage Footage Handling Unit(s) Number of Ventilation 2 Miscellaneous 1 Number of Plumbing 4 Fan(s) Mechanical Fixtures/Traps Number of Water 2 Water System Install Yes Transportation Uniform No Heater(s) or Alteration? Mitigation Fee Applicable City Development No Art in Public Places No Impact Fee Applicable Fund Exempt Type Group Sq Ft Value Printed: 5/13/25 4:14 pm Page 3 of 5 Permit Type Building Commercial BUILDING PERMIT Permit Number: Property Address BCOM2021-0083 78065 MAIN ST STE 101 Invoice No. Fee Fee Amount Amount Paid PERM IT-BCOM2021-00£ REMODEL, EA ADDITIONAL 500SF $72.45 $72.45 3 HOURLY CHARGE - CITY BUILDING STAFF $80.50 $80.50 VENT FAN $26.84 $26.84 WATER HEATER/VENT $26.84 $26.84 OTHER MECHANICAL EQUIPMENT PC $40.25 $40.25 OTHER MECHANICAL EQUIPMENT $40.25 $40.25 NON-RESIDENTIAL, FIRST 2,000SF $120.75 $120.75 NON-RESIDENTIAL, FIRST 2,000SF PC $93.38 $93.38 ART IN PUBLIC PLACES - COMMERCIAL REMOD $750.00 $750.00 REMODEL, FIRST 100SF PC $149.73 $149.73 FIXTURE/TRAP $53.68 $53.68 TECHNOLOGY ENHANCEMENT FEE $5.00 $5.00 FIRE COMMERCIAL TI $161.00 $161.00 WATER SYSTEM INST/ALT/REP PC $13.42 $13.42 REMODEL, EA ADDITIONAL 500SF PC $57.96 $57.96 BSAS SB1473 FEE $10.00 $10.00 SMI - COMMERCIAL $70.00 $70.00 FIRE COMMERCIAL TI PC $242.00 $242.00 FIXTURE/TRAP PC $53.68 $53.68 WATER HEATER/VENT PC $16.10 $16.10 WATER SYSTEM INST/ALT/REP $13.42 $13.42 AIR HANDLER $40.25 $40.25 RECORDS MANAGEMENT FEE - MAJOR $21.00 $21.00 VENT FAN PC $10.74 $10.74 REMODEL, FIRST 100SF $54.74 $54.74 AIR HANDLER PC $13.42 $13.42 Total for Invoice PERMIT-BCOM2021-0083 $2,237.40 $2,237.40 Grand Total for Permit $2,237.40 $2,237.40 Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 08/16/2021 0:00 ---------------------------------------------------------------------------------------------------------------------------------------- FINAL" v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- FINAL INSPECTION v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- T-BAR/OVERHEAD v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- DRYWALL NAIL v.4 Inspection --- --- --- -- - --------------------------------------------------------------------------------------------------------------------------- OVERHEAD ROUGH PIPING v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- WATER LINE v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- ROUGH ELEC v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- DRYWALL NAIL v.3 Inspection ------------------------------------------------ FRAMING v.1 Inspection --------------------------------------------- ROUGH PLBG v.1 Inspection -- - - - - - - - - - - - - - - - - - - - - - - -- ROUGH MECH v.2 Inspection ---------------- - - - - -- DRYWALL NAIL v.2 Inspection Printed: 5/13/25 4:14 pm Page 4 of 5 BUILDING PERMIT Permit Type: Building Commercial Permit Number: BCOM2021-0083 Property Address: 78065 MAIN ST STE 101 DRYWALL NAIL v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- ROUGH MECH v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND PLBG v.2 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND PLBG v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildina official. Printed: 5/13/25 4:14 pm Page 5 of 5 CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT uCv BILL WEISER — FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org August 23, 2021 Pacific Sotheby's International Realty 100 St. Paul #200 Denver, CO 80206 Re: Tenant Improvement Construction - Fire Plan Review — OTLQ — SOTHEBY'S LEASE SPACE BCOM2021-0083 / 78065 MAIN ST #101, LA QUINTA, CA 92253 The building plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Fire Department approval is based upon the 2019 CBC requirements for B occupancies. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy, without further review and approval. DEFERRED SUBMITTALS REQUIRED 1) FIRE SPRINKLER SYSTEM - Tenant Improvement plans must be submitted and reference the installing contractor performing the work. Permit fees will be required. 2) FIRE ALARM/MONITORING SYSTEM - For existing Fire Alarm Systems with Notification Appliances(if applicable) requiring modifications as affected by the Tenanat Improvement, plans must be submitted per NFPA 72 as required by the California Building Code, California Fire Code and designed in accordance with adopted standards. A C-10 licensed contractor must submit plans to the Office of the Fire Marshal for review and approval prior to installation. Permit fees will be required. PRIOR TO FINAL 1) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Minimum 6" tall suite addressing shall be provided to both the front and rear entrances. All addressing must be legible and of a contrasting color with the background to be visible from the street at all hours. 2) Provide keys to the tenant space (all tenants), utility rooms and elevator services for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. 3) A durable sign stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" shall be placed on or adjacent to the front exit doors. The sign shall be in letters not less than one inch high on a contrasting background (A <300, B, F, M and S). 4) Illuminated Exit Signage and Egress Illumination placement and functional test will be witnessed by OFM Fire Inspector at time of final inspection. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 Ciry: La Quinta Zip Code: 92253 Compliance Results: COMPLIES Enforcement Agency Use: Checked by/Date SHUT-OFF LIGHTING CONTROL ACCEPTANCE DOCUMENT Intent: This document is used to demonstrate compliance with acceptance requirements in §130.4(a)4 and Reference Nonresidential Appendix NA7.6.2 for shut-off lighting controls. Attach additional sets of pages 1 through 2, as required, for all controls that must be tested. Indicate all types of shut-off controls tested for this project: t✓ Automatic time switch lighting controls (Sections A-1 and B-1 of this document should be completed) r Occupant sensing lighting controls (including occupant sensors, partial -ON occupant sensors, partial -OFF occupant sensors, and/or vacancy sensors) (Sections A-2 and B-2 of this document should be completed) A-1. Automatic Time Switch Lighting Control Construction Inspection (NA7.6.2.4) I✓ a. Automatic time switch controls are programmed with acceptable weekday, weekend, and holiday (if applicable) schedules. (NA7.6.2.4(a), §110.9(b)1Aii, §130.1(c)lA, §130.1(c)4) W b. Document for the owner weekday, weekend, and holidays schedules, as well as all set-up and preference program settings. (NA7.6.2.4(b)) I✓ c. The correct time and date are properly set in the time switch. (NA7.6.2.4(c)) I✓ d. The battery backup (if applicable) is installed and energized. (NA7.6.2.4(d), §110.9(b)l) r e. Override time limit is no more than 2 hours. (NA7.6.2.4(e), §110.9(b)1Ai, §130.1(c)3B) OR The automatic time switch control's override time is exempt from the 2-hour limit. (EXCEPTION to §130.1(c)3B) t✓ f. Override switches remote from area with controlled luminaires have annunciator lights. (NA7.6.2.4(f), §130.1(c)3A, §130.1(a)) OR The manual override switch is exempt from being in the same enclosed area with the lighting it controls. (EXCEPTION 1 to §130.1(a)2) Construction Inspection Compliance: r Complies r Does Not Comply cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 1 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 B-1. Automatic Time Switch Lighting Control Functional Testing (NA7.6.2.5) Confirm compliance (Y - yes / N - no) for the control being tested. Building: All Areas Floor: Ground Level Room: All Areas Control: Automatic Time Switch Step 1: Simulate Occupied Condition. (NA7.6.2.5(a)) r a. All lights can be turned on and off by their respective area control switch. (NA7.6.2.5(a)l) r b. The switch only operates lighting in the enclosed space (ceiling -height partitioned area) in which the switch is located. (NA7.6.2.5(a)2, §130.1(c)1C) c. For the area controlled by an automatic time switch control with a time override located in and for the area, the lighting can be turned on manually by initiating the time override. The lighting is configured to remain on for no more than 2 hours, unless the area is exempt from the 2-hour time override limit. (NA7.6.2.5(a)3, §110.9(b)lAi, §130.1(c)3B, EXCEPTION to §130.1(c)3B) r d. For the area controlled by an automatic time switch control with an automatic holiday shut-off feature, the lighting in the area can be turned off automatically by initiating the holiday shut-off. (NA7.6.2.5(a)4, §110.9(b)lAii, §130.1(c)4) OR The automatic time switch control is exempt from incorporating an automatic holiday shut-off feature. (EXCEPTION to §130.1(c)4) r e. For the area controlled by an automatic time switch control with manual -on mode configured, the lighting in the area can be turned on manually when it is manually activated. (NA7.6.2.5(a)5, §130.1(c)IE) OR The automatic time switch control does not include or utilize a manual -on mode. (§130.1(c)1E) Step 2: Simulate unoccupied condition. (NA7.6.2.5(b)) r a. All non-exempt lighting turns off in accordance with the programmed time switch schedules. (NA7.6.2.5(b)l, §130.1(c)1A) r b. Manual override switch allows only the lights in the enclosed space (ceiling height partitioned) where the override switch is located to turn on or remain on until the next scheduled shut off occurs. (NA7.6.2.5(b)2, §130.1(c)1C, §130.1(c)3) Functional Testing Compliance: Complies 4 Does Not Comply COAL California California Advanced Lighting Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 2 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 A-2. Occupant Sensing Lighting Control Construction Inspection (NA7.6.2.2)) r a. Occupant sensors have been located to minimize false signals. (NA7.6.2.2(a)) r b. Occupant sensors are located no closer than four (4) feet from any HVAC diffuser. (NA7.6.2.2(b)) r c. Passive infrared sensor pattern does not enter into adjacent zones. (NA7.6.2.2(c)) I✓ d. Occupant sensors do not encounter any obstructions that could adversely affect desired performance. (NA7.6.2.2(d)) I✓ e. Ultrasonic occupant sensors do not emit audible sound. (NA7.6.2.2(e), §110.9(b)6Bii) Construction Inspection Compliance: 4 Complies r Does Not Comply B-2. Occupant Sensing Lighting Control Functional Testing (NA7.6.2.3) Confirm compliance (Y - yes / N - no) for the control being tested. Building: Conference Room Floor: Ground Level Room: Conference Room Control: Occupancy Sensor r— Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION 1 to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). r b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) r c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) r a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 3 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 Complies 4 Does Not Comply Building: Restroom Floor: Ground Level Room: Restroom Control: Occupancy Sensor r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION 1 to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). r b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) r a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: Complies • Does Not Comply Building: Offices Floor: Ground Level Room: Office (<= 250 square feet) Control: Occupancy Sensor COAL California California Advanced Lighting Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 4 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). P b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) P a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: C• Complies r Does Not Comply Building: Reception Floor: Ground Level Room: Main Entry Lobby Control: Occupancy Sensor cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 5 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). r b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) P a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: C• Complies r Does Not Comply Building: Hallway Floor: Ground Level Room: Corridor Area Control: Occupancy Sensor cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 6 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). P b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) P a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: C•' Complies r Does Not Comply Building: IT Closet Floor: Ground Level Room: Electrical, Mechanical, Telephone Rooms Control: Occupancy Sensor cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 7 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). P b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) P a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: C• Complies r Does Not Comply Building: Break Room Floor: Ground Level Room: Lounge Breakroom or Waiting Area Control: Occupancy Sensor cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 8 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta Zip Code: 92253 r Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). P b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) P a. Status indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(b)4C) r b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: C• Complies r Does Not Comply cAL��` TP CallfomlaAdvanced Lighting I Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 9 of 10 CERTIFICATE OF ACCEPTANCE NRCA-LTI-02-A Lighting Control Project Name: Pacific Sotheby's Enforcement Agency: CITY OF LA QL INTA Permit Number: BCOM2021-0083 Project Address: 78065 E. Main St., Suite C101 City: La Quinta IZip Code: 92253 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Acceptance documentation is accurate and complete. Documentation Author Company Name Name Jeff Bernardino Integrated Power & Lighting Inc Address City/State/Zip 3312 Limerick Lane Corona, CA 92882 Phone (951)270-0575 Author Signature Date of Signature: 06/10/2022 CEA/ATT Certification Identification (if TC-A813601 annlirahlp) FIELD TECHNICIAN'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Acceptance is true and correct. 2. I am the person who performed the acceptance verification reported on this Certificate of Acceptance (Field Technician). 3. The construction or installation identified on this Certificate of Acceptance complies with the applicable acceptance requirements indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NA7. 4. I have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and signed by the responsible builder/installer and has been posted or made available with the building permit(s) issued for the building. Field Technician Name Company Name Jeff Bernardino Integrated Power &Lighting Inc Address: City/State/Zip 3312 Limerick Lane Corona, CA 92882 Phone ATT Certification (951)270-0575 Identification TC-A813601 Position with Company Field Technician Signature (Title) Presiden -J - "O--ftb Date of Signature: 06/10/2022 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am the Field Technician, or the Field Technician is acting on my behalf as my employee or my agent and I have reviewed the information provided on this Certificate of Acceptance. 2. I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Acceptance and attest to the declarations in this statement (responsible acceptance person). 3. The information provided on this Certificate of Acceptance substantiates that the construction or installation identified on this Certificate of Acceptance complies with the acceptance requirements indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NA7. 4. I have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and is posted or made available with the building permit(s) issued for the building. 5. I will ensure that a completed, signed copy of this Certificate of Acceptance shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Certificate of Acceptance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Acceptance Company Name Person Name Jeff Bernardino Integrated Power & Lighting Inc Address: City/State/Zip 3312 Limerick Lane Corona, CA 92882 Phone CSLB License (951)270-0575 993105 Position with Company Responsible Acceptance Person Signature (Title) President Date of Signature: 06/10/2022 COAL California California Advanced Lighting Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 10 of 10 WALL CONTINUES TO STRUCTURE, SEE DETAILS THIS SHEET FOR TOP OF WALL CONNECTION REQUIREMENTS. 1-1/2"x1-1/2" TRACK, 20 GAUGE WITH LEG AT STUD DOWN, FASTEN #8xX1/2" SELF -DRILLING PAN HEAD SCREW. AT END OF EACH STUD LONG -LEG STEEL SLOTTED STEEL TRACK, SEE DETAILS THIS SHEET FOR TOP OF WALL CONNECTION 2-1/2", 20 GAUGE METAL STUDS @ 16" O.C. FASTENED REQUIREMENTS. TO TRACK WTIH #8xX1/2" SELF -DRILLING PAN HEAD #8x1/2" SELF -DRILLING PAN HEAD SCREWS IN SLOTTED SCREW. AT END OF EACH STUD TOP TRACK. ONE EACH SIDE OF SPLICED STUD. STUD BRACES TO BOTTOM OF FLOOR -CEILING ASSEMBLY ATTACHED TO + z4 4, OPPOSING FLANGE OVERLAPPING SPLICE DETAIL HORIZONTAL STUDS AND PERPENDICULAR - AT LONGER SPANS. USE #8x1/2" SCREWS N N I AT ALL CONNECTIONS I „ 1-1/2", 20 GAUGE STUDS @ 48 O.C. MAX. ATTACHED TO TRACK AND #8x1/2" SELF -DRILLING PAN HEAD SCREWS. TWO EACH PERPENDICULAR STUDS #8xX1/2" SELF -DRILLING PAN HEAD SCREW. AT O SIDE OF STUD OPPOSING FLANGE OVERLAPPING SPLICE. END OF EACH STUD a — — — — — — — — — — 4'-0" O.C. (54" MAX. O.C.) — — —-------- ------------- I I 5/8" GYPSUM BOARD WALL AND CEILING 5/8" GYPSUM BOARD CEILING OR SUSPENDED I ACOUSTICAL CEILING WHERE OCCURS. 3-5/8" OR 6" STUD WALL, 20 GAGE @ 16" O.C. 0 l01 WITH 5/8" GYPSUM BOTH SIDES 3-5/8" OR 6" STUD WALL, 20 GAGE @ 16" O.C. WITH 5/8" GYPSUM BOTH SIDES WALL CONTINUES TO FLOOR BELOW, SEE DETAILS THIS WALL CONTINUES TO FLOOR BELOW, SEE DETAILS THIS SHEET FOR BOTTOM OF WALL CONNECTION REQUIREMENTS. SHEET FOR BOTTOM OF WALL CONNECTION REQUIREMENTS. FRAMED GYPSUM BOARD CEILING DETAI SPLICE DETAIL at WALLS L 15 L23 SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" EXISTING FLOOR SHEATHING OR ROOF DECK EXISTING FLOOR SHEATHING OR ROOF DECK PROVIDE DIAGONAL STUD BRACES (3-5/8" 20 GAGE), ALTERNATING SIDES AT 4'-0" O.C. (8'-0" PER SIDE), 7 ATTACHED TO BOTTOM OF DECK WIDE FLANGE CONT. SLOTTED 16 GA. TRACK WITH (2) NO. 6 SCREWS AT 24" O.C. PROVIDE TRACK TO ALLOW FOR 1" / / WIDE FLANGE CONT. SLOTTED 16 GA. TRACK WITH (2) NO. 6 DEFLECTION / / SCREWS AT 24" O.C. / / PROVIDE TRACK TO ALLOW FOR 1" DEFLECTION • 3-5/8" OR 6" STUD WALL, 20 GAGE @ 2'-0" O.C. WITH 5/8" GYPSUM BOTH SIDES — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------------------------- SUSPENDED ACT CEILING SUSPENDED CEILING NEW BOTTOM TRACK ATTACHED TO TOP OF EXISTING TOP TRACK 5/8" GYP. BRD. BOTH SIDES 3-5/8" OR 6" 20 GA. METAL STUDS AT 16" OR 24" O.C. AT SLAB ON GRADE: ATTACH WITH POWER DRIVEN FASTENERS AT 24" O.C. (1" EXISTING 3-5/8" OR 6" 20 GA. METAL STUDS WALLS PENETRATION) I.C.B.O. NO 1290 WITH (1) LAYER 5/8" GYPSUM BOARD EACH SIDE. AT WOOD FLOOR SHEATHING (2) NO. 6 SCREWS AT 24" O.C. JOINT SEALER WALL DETAIL at NEW WALLS WALL DETAIL at EXTENDED WALLS 1 23 SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" W AXNVA )ph: oseph Ward Architecture, Inc. 0 Box 956 abernash, Colorado 80478 (530) 386-6097 T AlummERILL NaD ARCy%' �a JOSEPH**-. G �' W C-34305 s ,; RE .08-31-23 .� Yti9lF of CA�,Fl� 9 (D Q Cow) W E P 0. Cn O W (D > L N � (D O C) M Cz � V 0 N _� C 0 CZ K (D O J O O w H RIVERSIDE COUNTY APN: 770-121-012 G PROJ. NO. 2105.00 DRAWN: JSW CHECKED: — F CAD FILE: SPS—Plan DATE: 8/13/21 REVISIONS: E PLAN REVIEW COMMENTS — 1 9/2/21 FRAMING DETAILS — 7 3/4/22 D ©Joseph Ward Architecture, Inc ISSUED FOR: PERMIT SET c SHEET TITLE: ZL Details NEW SHEET B SCALE: 3/4" = 1'-0" SHEET NUMBER: A300 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Certificate of Occupancy Design and Development Department — GEM of the DESEKI' — This Certificate is issued pursuant to the requirements of Chapter 1 Section 111 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78065 MAIN ST STE 101 Use classification: BUSINESS - OFFICE Occupancy Group: B Type of Construction: VB Code Edition: 2019 By: AJ ORTEGA Date: 6/24/2022 Building Official: AJ ORTEGA Sprinkler Installed: YES Permit No.: BCOM2021-0083 Land Use Zone: VC Occupant Load: 11 Owner of Building: OLD TOWN LA QUINTA LLC Address City, ST, ZIP: POST IN A CONSPICUOUS PLACE 78010 MAIN ST NO 201 LA QUINTA