Loading...
BCOM2020-0033 - Plans1. RECYCLING. A MINIMUM OF 65% OF CONSTRUCTION WASTE IS TO BE RECYCLED. CGC SECTION 4.408.1 2. RECYCLING. THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN, PER CGC SECTION 4.408.2 3. OPERATION AND MAINTENANCE MANUAL. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL (CONTAINING INFORMATION FOR MAINTAINING APPLIANCES, ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION. CGC SECTION 4.410.1. 4. POLLUTANT CONTROL. DURING CONSTRUCTION END OF DUCTS OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED. CGC SECTION 4.504.1. 5. POLLUTANT CONTROL. VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED IN SECTION 4.503 AND TABLES 4.504.1, 4.504.2, 4.503 AND 4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC SECTION 4.504.2. 6. INTERIOR MOISTURE CONTROL. THE MOISTURE CONTENT OF THE WOOD SHALL NOT EXCEED 19% BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF THREE METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION. THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC 102.3. 7. INDOOR AIR QUALITY. BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TO THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT. CGC 4.506.1. 8. PRIOR TO FINAL INSPECTION THE LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST PROVIDE TO THE BUILDING DEPARTMENT OFFICIAL WRITTEN VERIFICATION THAT ALL APPLICABLE PROVISIONS FROM THE GREEN BUILDING STANDARDS CODE HAVE BEEN IMPLEMENTED AS PART OF THE CONSTRUCTION. CGC 102.3. 9. STORM WATER DRAINAGE RETENTION DURING CONSTRUCTION. PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL SHALL MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION BY ONE OF THE FOLLOWING: A.RETENTION BASINS B.WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER APPROVED METHOD. CGC SECTION 4.106.2 10. GRADING AND PAVING. SITE GRADING OR DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS (SWALES, WATER COLLECTION, FRENCH DRAINS, ETC). CGC SECTION 4.106.3. EXCEPTION: ADDITIONS NOT ALTERING THE DRAINAGE PATH. 11. LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER OR SOIL BASED CONTROLLERS. CGC SECTION 4.304.1. COVER SHEET W/ GENERAL NOTES A0 N.T.S EXISTING TENANT SPACE OF APPROXIMATELY 2,783 SQ.FT IS PROPOSING A 256 SQ.FT. BAR REMODEL. THE EXISTING BAR AREA WILL HAVE SOME DEMOLITION BY REMOVING THE COUNTERTOPS AND PARTIAL PONY WALLS TO CREATE A SIMPLE "L" SHAPED BAR. NEW COUNTER WILL BE ADDED WITH AN EXTENSION OF A NEW PONY WALL ALONG WITH A UNDERCOUNTER BAR SINK. THE SPACE WILL NOW BE A WASHING STATION. A NEW BAR WILL BE BUILT AT THE CURRENT DINING AREA. THE NEW BAR WILL HAVE MATCHING COUNTERTOPS WITH A NEW ADA COUNTER AND A NEW HANDSINK, UNDER BAR REFRIGERATOR, AND TAPS FOR THE BEER. A NEW WALK-IN COOLER WILL BE ADDED BEHIND THE WASHING STATION. NEW POWER WILL BE ADDED FOR THE WALK-IN REFRIGERATOR, AND TWO DEDICATED CIRCUITS AT THE NEW BAR. ALL ELECTRICAL LIGHTING, LIGHTING CONTROLS, AND SWITCHING TO REMAIN. ALL MECHANICAL HVAC AND DUCTING WILL NOT BE ALTERED. EXISTING KITCHEN WILL NOT BE ALTERED. NO STRUCTURAL WORK. FOR PLUMBING WILL ADD THREE NEW FLOOR SINKS, ONE FLOOR DRAIN, AND NEW WATER LINES AT NEW BAR FOR NEW HAND SINK. ALL RESTROOMS ARE CURRENT ADA AND WILL NOT BE ALTERED. NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS BCOM2020-0033 LA QUINTA BREWING COMPANY / TENANT IMPROVEMENT [VB/A-2 OCC/77-OL/SPRINKLED] . CREATE NEW BAR AREA, CONVERT EXISTING SERVICE COUNTER TO WAIT STATION, AND INSTALL NEW WALK-IN COOLER. THIS PERMIT DOES NOT INCLUDE STRUCTURAL ALTERATIONS NOR CHANGES TO THE MEANS OF EGRESS SYSTEM. 2019 CALIFORNIA BUILDING CODES. 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS A1 EXISTING SITE PLAN 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS A2 EGRESS PLAN 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS A2.1 WALL LEGEND DEMOLITION PLAN REMOVE EXISTING PONY WALL AT BAR REMOVE CABINETRY REMOVE CABINETRY REMOVE CABINETRY REMOVE EXISTING PONY WALL REMOVE STONE COUNTERTOP 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS A2.2 WALL LEGEND ALL GENDER SIGN 1/4" THICK EQUILATERAL TRIANGLE OVER 1/4" THICK 12" CIRCLE EXIT TES ISA FLOOR PLANS EXISTING ALUMINUM STOREFRONT WINDOW INTERIOR WALL. 3-5/8" 25 GA. METAL STUDS @ 24" O.C. WITH 5/8" DRYWALL ONE SIDE. TEXTURE TO MATCH EXISTING 48"X48" 60"X60" 48"X48" 1 1 24 3 2 1 24 3 3 1 24 3 4 1 24 3 5 1 24 3 1 3 2 4 5 6 6 ALL GENDER NEW GLU-LAM BAR COUNTER 42" MAX HGT. ADA COUNTER 34" MAX HGT. EXISTING PONY WALL AT EXISTING BAR NEW PONY WALL AT EXISTING BAR. 6" 20 GA METAL STUDS @24" O.C. W/ 5/8" GREENBOARD & FRP FINISH AT WASHING STATION SIDE. 5/8" GYP. AT CUSTOMER SIDE 48"X48" 60"X60" 48"X48" MIN. MI N . NEW GLU-LAM COUNTERTOP (E)EMPLOYEE LOCKERS NEW STONE COUNTERTOP (NON-POROUS) NEW BEER TAPS NEW GLU-LAM BAR COUNTER 42" MAX HGT. 6 NEW SEALED CONCRETE FLOOR NEW SEALED CONCRETE FLOOR (E)EPOXY FLOOR (E)EPOXY FLOOR (E)EPOXY FLOOR (E)EPOXY FLOOR (E)CERAMIC TILE FLOOR (E)CERAMIC TILE FLOOR 7 8 TES ISA TE S IS A NEW WALK-IN EVAP COIL (E)CONC. PAD FI N I S H W I D T H MIN. 09/15/2020 INTERIOR ELEVATIONS A-3 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS 3SCALE: 1/4"=1'-0" 1NOT TOSCALE 2SCALE: 1/4"=1'-0"BAR DETAIL ADA COUNTER 4SCALE: 1/4"=1'-0"ADA COUNTER KNEE CLEARANCE 5SCALE: 1/4"=1'-0" SECTION VIEW ADA COUNTER 9 PLAN VIEW ADA COUNTER SECTION VIEW ADA COUNTER ADACOUNTER TOE CLEARANCESCALE: 1/4"=1'-0" 0'-0" FIN. FLOOR 1 2 WOOD STAINED BASE PLAN VIEW 6 GLU-LAM COUNTER MA X GLU-LAM COUNTER TAPROOM 1 1 1 24 3 4 1 24 3 0'-0" FIN. FLOOR 4 3 NEW SLIM FOOT TILE NEW GLU-LAM COUNTERNEW GLU-LAM COUNTER NEW BAR NEW FRP PANELS7 5 NEW FRP PANELS NEW FRP PANELS & DETAILS PLAN VIEW ADA COUNTER 5/8" FIRE RATED GYPSUM BOARD ONE SIDE MATCH EXISTING TEXTURE #8 SELF-TAPPING 1/2" METAL SCREW @ 24" BOTH SIDES 3-5/8" OR 6" 25 GA. METAL STUDS @ 24" O.C. ICC#ESR-4792, ER4943 & 5089P CONTINUOUS 3-5/8" 20 GA. TRACT ICC#ESR-4792, ER4943 & 5089P TYPICAL NON-LOAD BEARING WALL DETAIL NEW SLIM FOOT TILE NEW STONE COUNTERTOP (NON-POROUS) 24" WOOD FINISH BASE CABINET NEW BEER TAPS BY CONSULTANT ADJUSTABLE SHELVES 4 1 NEW BAR SEALED CONCRETE PLASTER FULL HEIGHT #8 SCREWS @ 24"O.C. BOTH SIDES 3-5/8" 20 GA. CONTINUOUS TRACT W/HILTI X-U 32 P8/S15 COMBO PIN POWDER ACTUATED, 0.157" DIAMETER X 1-1/4" LONG @ 24" O.C. & 6" FROM ENDS ICC#ESR-1752, OR EQUAL (N)5/8" GYP. BRD. (N)WOOD PANELING (N)SEALED CONCRETE FLOORING (N)SEALED CONCRETE FLOORING. (MUST BE HEALTH DEPT APPROVED) (N)6" QUARRY TILE "SLIMFOOT" STYLE (N)5/8" GYP. BRD. WATER RESISTANT GREEN BOARD (N)FRP. BRD. (N)GLU-LAM COUNTERTOP STAINED & SEALED (N)1/4"X2" LAG SCREWS W/FLAT WASHERS @48" (N)2"WX24"LX1/4"THICK STEEL STRAP FOR BRACING, BENT 90° HIDDEN IN GYP. BRD. AND RECESSED AT COUNTER W/(5)#8 METAL SCREWS @ 48" +42" AFF +34" AFF ADA 3-5/8" 20 GA. CONTINUOUS TRACT W/HILTI X-U 32 P8/S15 COMBO PIN POWDER ACTUATED, 0.157" DIAMETER X 1-1/4" LONG @ 24" O.C. & 6" FROM ENDS ICC#ESR-1752, OR EQUAL 3-5/8" OR 6" 20 GA. METAL STUDS @ 24" O.C. ICC#ESR-4792, ER4943 & 5089P CONTINUOUS 3-5/8" OR 6" 20 GA. TRACT ICC#ESR-4792, ER4943 & 5089P WOOD PANEL FINISH WIDTH FINISH WIDTH 09/15/2020 J E-1 ELECTRICAL POWER PLAN NOTES & DETAILS NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS 48"X48" 60"X60" 48"X48" 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS P1 PLUMBING PLAN Trap primer if required by local authorities. Otherwise deep- seal P-trap. FLOOR SINK GRATE COVER INDIRECT DRAIN FINISH FLOOR AIR GAP 1 INCH Typ. Indirect waste @Floor Sink Detail N.T.S. 2% M I N (E)4"SWR (E)4"SEWER (E)3"CLEAN-OUT TO GROUND (E)3"CLEAN-OUT TO GROUND (E ) 3 " S W R (E ) 2 " S W R (E ) 3 " S W R (E)F.D. (E)F.D. (E)F.D. (E)2"(E)FLR SINK (E)2" (E ) 2 " (E)VENT (E)VENT (E)2" (E)2" (E)3-COMP SINK (E)ICE MACHINE (E)MOP SINK (E)WH 100 GAL (E)PREP SINK (E)HAND SINK (E ) 3 " S W R (E)3"CLEAN-OUT TO GROUND (E)FLR SINK (E)HAND SINK (N ) 2 " S W R (N)2"VNT (N)2" VNT NOTE: HORIZONTAL RUNS OF DRAIN LINES SHALL BE OFFSET AT LEAST 1/2" FROM THE WALL WITH EASILY CLEANABLE CLAMPS & SHALL BE 6" OFF THE FLOOR & SHALL TERMINATE AT LEAST 1" ABOVE THE OVERFLOW RIM OF THE FLOOR SINK. NOTE: -ALL SEWER PIPES THAT ARE SMALLER THAN 4" MUST HAVE A MINIMUM SLOPE OF 2%. CPC 708.1 (N)2"VNT (E)2"SWR (N)2"SWR CONNECT TO EXIST. VENT LINES MINIMUM SEPARATION WHEN SEWER PIPING MATERIAL ARE USED WITH WATER PIPE WATER LINE 12" 12" 2" SEWER 1-1/2" VENT 6"MINIMUM (E) CONC SLAB NEW CONSTRUCTION (E) CONC SLAB 6"6"6"6" WIRE TIED # 4'S @12" OC.(E) SLAB # 4 DOWELS @ 12" OC EPOXY INTO (E) SLAB 6", USE SIMPSON EPOXY "SET" ICC# 1772 NOTES 1- CONTRACTOR TO SAW CUT SLAB AS MINIMALLY AS POSSIBLE AND REMOVE EXISTING CONCRETE SLAB TO INSTALL UNDERGROUND UTILITIES AS SHOWN ON THE DRAWINGS. 2- CONTRACTOR TO BACK FILL IN 6" LIFTS TO OBTAIN 98% COMPACTION. 3- REPLACE DEMO'D CONCRETE WITH A MIN OF 2,500 PSI CONCRETE WITH "STEEL TROWELLED" FINISH TO MATCH EXISTING. # 4'S @ 12" OC WIRE TIED TO DOWELS LAP DOWELS 5" MIN & TIE PER CODE Min. Separation Utilities Detail N.T.S2 1Sawcut Concrete Detail N.T.S.3 A. SOLDER SHALL BE LEAD FREE COMPLYING WITH THE PROVISIONS OF FEDERAL CLEAN DRINKING WATER ACT AND THE CALIFORNIA PLUMBING CODE (CPC) 2016 EDITION. B. WATER HEATERS SHALL BE EQUIPPED WITH A COMBINATION PRESSURE AND TEMPERATURE RELIEF VALVE PER CPC SECTION 505.6 AND RELIEF C. WATER PRESSURE REGULATING VALVE SHALL BE INSTALLED WHERE D. PLUMBING FIXTURE SHALL BE LISTED IN CONFORMANCE WITH CPC CHAPTER 4 "PLUMBING FIXTURES". E. DOMESTIC WATER HEATERS SHALL BE CERTIFIED AND LISTED BY THE CALIFORNIA ENERGY COMMISSION. EXTERIOR INSULATION SHALL BE R-16, OR GREATER. THE FIRST 5 FEET OF EXPOSED HOT AND COLD WATER PIPING AND THE WATER HEATER SHALL BE INSULATED. TITLE 24 SEC. 2-5318 (A). F. CIRCULATING HOT WATER SYSTEMS SHALL BE FULLY INSULATED AND SHALL HAVE CONTROL (TIME CLOCK) CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMP(S) WHEN HOT WATER IS NOT REQUIRED. TITLE 24 SECTION 2-5318 (B) 2. G. WATER CLOSETS, URINALS, SHOWER HEADS, LAVATORY FAUCETS, AND SINK FAUCETS SHALL MEET THE FLOWING REQUIREMENTS OUTLINED IN THE TITLE 24 "APPLIANCE EFFICIENCY STANDARDS" SECTION 2-5134. WATER CLOSETS URINALS LAVATORIES SINKS H. SHOWER AND TUB/SHOWER CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING TYPE. HANDLE POSITION SPOTS SHALL BE PROVIDED ON THESE VALVES AND SHALL BE ADJUSTED TO DELIVER A MAXIMUM WATER SETTING OF 120 F PER CPC SECTION 418.0. I. WATER HEATERS SHALL BE STRAPPED OR ANCHORED TO RESIST SEISMIC BY A LICENSED ENGINEER AND/OR PER CPC. J. WATER HEATERS LOCATED IN ATTIC OR FURRED SPACE WHERE DAMAGE K. DRAIN PIPING SHALL SLOPE AT 2% OR 1/4" PER FOOT FOR ALL PIPING UNLESS OTHERWISE NOTED. PIPING 4" AND LARGER REQUIRING SLOPE OR LESS THAN 2% DUE TO INSTALLATION CONDITIONS SHALL BE NOTED ON THE PLANS AND APPROVAL RECEIVED FROM THE ADMINISTRATIVE AUTHORITY PER CPC SECTION 708.0. L. FLOOR DRAINS AND FLOOR SINKS WHICH ARE SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC METHOD OF MAINTAINING TRAP SEALS PER CPC SECTION 1005.0. M. VENT TERMINATION SHALL BE NOT LESS THAN 10 (TEN) FEET FROM OR AT LEAST 3 (THREE) FEET ABOVE AIR INLET PER CPC SECTION 906.2. N. PLUMBING MATERIALS: DWV BELOW SLAB WASTE ABOVE SLAB VENTS ABOVE SLAB SEWER WATER BELOW SLAB WATER ABOVE SLAB WATER SERVICE GAS ABOVE GRADE GAS BELOW GRADE ROOF DRAIN PIPING A.G. ROOF DRAIN PIPING B.G. CONDENSATE PIPING VALVES O. INSTALLATION OF ALL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH APPLICABLE LAPMO INSTALLATION STANDARDS AND LISTED IN CPC APPENDIX I. P. A MINIMUM OF 12" ACCESS PANEL TO BATHTUB TRAP CONNECTIONS SHALL BE INSTALLED WHEN SLIP JOINT CONNECTIONS ARE USED PER Q. ALL HOSE BIBBS AND FAUCETS FITTED WITH THREADED CONNECTIONS SHALL BE FITTED WITH AN APPROVED NON-REMOVABLE BACK FLOW DEVICE PER CPC SECTION 603. R. BUILT-UP SHOWER RECEPTORS SHALL BE INSTALLED AND INSPECTED UPON COMPLETION OF WATER PROOFING PER CPC SECTION 411.5 AND S. WATER PRESSURE REGULATORS SHALL BE INSTALLED ON THE WATER SERVICE PRIOR TO CONNECTION TO BUILDING IF PRESSURES EXCEEDS 80 PSI PER CPC SECTION 608.2. T. WATER SYSTEM SHALL BE STERILIZED USING A CHLORINE SOLUTION, TESTED AND CERTIFICATION PROVIDED FROM APPROVED TESTING U. HANGERS AND SUPPORTS SHALL BE BY A RECOGNIZED MANUFACTURER SPECIALIZING IN THESE PRODUCTS, SUCH AS MCO, BLINE, ETC. V. ALL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE CALIFORNIA PLUMBING CODE AND WITNESSED BY THE LOCAL BUILDING AUTHORITY AND OWNERS REPRESENTATIVE. 0.5 GPM 1.8 GPM ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SDR 35 ___ABS SCHED 40 ___HUBLESS CAST IRON ___COPPER TYPE K ___COPPER TYPE L ___COPPER TYPE M ___COPPER TYPE L ___COPPER TYPE K ___PVC SCHED 40 ___COPPER TYPE K ___PVC SCHED 80 ___STEEL PIPE BLACK. SCHED 40 ___PVC SCHED 40 NAT GAS ___POLYETHYLENE ___STEEL PIPE SCHED 40 WRAPPED ___ABS SCHED 40 NAT GAS ___HUBLESS CAST IRON ___ABS SCHED 40 NAT GAS ___HUBLESS CAST IRON ___RECTANGULAR CAST IRON ___RECTANGULAR FIBERGLASS INSULATION REQUIRED ___PVC SCHED 40 ___COPPER TYPE M ___DWV _____ ___COLD WATER ____ ___HOT WATER ____ ___CONDENSATE X F.G. JACKETED Y C.C. POLYETHYLENE Z ELASTOMERIC ALL VALVES SHALL BE BY A KNOWN MANUFACTURER. NO GATE VALVES SHALL BE USED ___PVC SCHED 40 ___PVC SCHED 80 ___COPPER TYPE M A. SOLDER SHALL BE LEAD FREE COMPLYING WITH THE PROVISIONS OF B. WATER HEATERS SHALL BE EQUIPPED WITH A COMBINATION PRESSURE VALVES SHALL TERMINATE PER CPC SECTIONS 608.3, 608.4, 608.5, AND 608.6. C. WATER PRESSURE REGULATING VALVE SHALL BE INSTALLED WHERE STATIC WATER PRESSURE IS IN EXCESS OF 80 PSI PER UPC. CHAPTER 4 "PLUMBING FIXTURES". E. DOMESTIC WATER HEATERS SHALL BE CERTIFIED AND LISTED BY THE CALIFORNIA ENERGY COMMISSION. EXTERIOR INSULATION SHALL BE R-16, OR GREATER. THE FIRST 5 FEET OF EXPOSED HOT AND COLD WATER PIPING AND THE WATER HEATER SHALL BE INSULATED. TITLE 24 SEC. 2-5318 (A). F. CIRCULATING HOT WATER SYSTEMS SHALL BE FULLY INSULATED AND SHALL HAVE CONTROL (TIME CLOCK) CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMP(S) WHEN HOT WATER IS NOT REQUIRED. TITLE 24 SECTION 2-5318 (B) 2. G. WATER CLOSETS, URINALS, SHOWER HEADS, LAVATORY FAUCETS, AND SINK FAUCETS SHALL MEET THE FLOWING REQUIREMENTS OUTLINED IN THE TITLE 24 "APPLIANCE EFFICIENCY STANDARDS" SECTION 2-5134. WATER CLOSETS URINALS LAVATORIES SINKS H. SHOWER AND TUB/SHOWER CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING TYPE. HANDLE POSITION SPOTS SHALL BE PROVIDED ON THESE VALVES AND SHALL BE ADJUSTED TO DELIVER A MAXIMUM WATER SETTING OF 120 F I. WATER HEATERS SHALL BE STRAPPED OR ANCHORED TO RESIST SEISMIC J. WATER HEATERS LOCATED IN ATTIC OR FURRED SPACE WHERE DAMAGE MAY RESULT FROM LEAKING SHALL BE INSTALLED IN OR OVER A WATER TIGHT PAN WITH A 3/4 INCH DRAIN TO AN APPROVED LOCATION PER CPC SECTION 5O8.2 K. DRAIN PIPING SHALL SLOPE AT 2% OR 1/4" PER FOOT FOR ALL PIPING UNLESS OTHERWISE NOTED. PIPING 4" AND LARGER REQUIRING SLOPE ON THE PLANS AND APPROVAL RECEIVED FROM THE ADMINISTRATIVE L. FLOOR DRAINS AND FLOOR SINKS WHICH ARE SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC METHOD OF M. VENT TERMINATION SHALL BE NOT LESS THAN 10 (TEN) FEET FROM OR N. PLUMBING MATERIALS: DWV BELOW SLAB WASTE ABOVE SLAB VENTS ABOVE SLAB SEWER WATER BELOW SLAB WATER ABOVE SLAB WATER SERVICE ROOF DRAIN PIPING A.G. ROOF DRAIN PIPING B.G. CONDENSATE PIPING VALVES INDIRECT WASTE O. INSTALLATION OF ALL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH APPLICABLE LAPMO INSTALLATION STANDARDS AND LISTED P. A MINIMUM OF 12" ACCESS PANEL TO BATHTUB TRAP CONNECTIONS SHALL BE INSTALLED WHEN SLIP JOINT CONNECTIONS ARE USED PER CPC. SHALL BE FITTED WITH AN APPROVED NON-REMOVABLE BACK FLOW R. BUILT-UP SHOWER RECEPTORS SHALL BE INSTALLED AND INSPECTED S. WATER PRESSURE REGULATORS SHALL BE INSTALLED ON THE WATER SERVICE PRIOR TO CONNECTION TO BUILDING IF PRESSURES EXCEEDS T. WATER SYSTEM SHALL BE STERILIZED USING A CHLORINE SOLUTION, TESTED AND CERTIFICATION PROVIDED FROM APPROVED TESTING FACILITY. U. HANGERS AND SUPPORTS SHALL BE BY A RECOGNIZED MANUFACTURER SPECIALIZING IN THESE PRODUCTS, SUCH AS MCO, BLINE, ETC. V. ALL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE APPLICABLE LOCAL BUILDING AUTHORITY AND OWNERS REPRESENTATIVE. 1.28 GPF 0.125 GPF ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SCHED 40 ___HUBLESS CAST IRON ___ABS SDR 35 ___ABS SCHED 40 ___HUBLESS CAST IRON ___COPPER TYPE K ___COPPER TYPE L ___COPPER TYPE M ___COPPER TYPE L ___COPPER TYPE K ___PVC SCHED 40 ___COPPER TYPE K ___PVC SCHED 80 ___PVC SCHED 40 NAT GAS ___POLYETHYLENE ___STEEL PIPE SCHED 40 WRAPPED ___ABS SCHED 40 NAT GAS ___HUBLESS CAST IRON ___ABS SCHED 40 NAT GAS ___HUBLESS CAST IRON ___RECTANGULAR CAST IRON ___RECTANGULAR FIBERGLASS INSULATION REQUIRED ___PVC SCHED 40 ___COPPER TYPE M ___DWV _____ ___COLD WATER ____ ___HOT WATER ____ ___CONDENSATE X F.G. JACKETED Y C.C. POLYETHYLENE Z ELASTOMERIC ALL VALVES SHALL BE BY A KNOWN MANUFACTURER. NO GATE VALVES SHALL BE USED ___PVC SCHED 40 ___PVC SCHED 80 ___COPPER TYPE M INSTALLATION NOTES LOADING. STRAPPING SHALL BE AS DETAILED IN APPROVED DRAWINGS X X X X X X X X X X 411.6. PLUMBING FIXTURE SCHEDULE SYM ITEM MFG/MODEL TRIM DESCRIPTION/COMMENTS 1-1/2" NEW METER SIZE 1" 2"F/U 1-1/4" 1-1/2" 1/2" 3/4" 1" TOTAL FIXTURE UNITS CHART REFLECTS HW AND CW 1.0(E)LAVATORIES (E)WATER CLOSETS FIXTUREQTY. 4 F/U 2.5 DEMAND MAXIMUM F/U REQUIRED GPM WATER SERVICE TO MOST REMOTE OUTLET: AT CONNECTION POINT: FROM CONNECTION POINT TOTAL DEVELOPMENT LENGTH FROM REG. TO METER: PRESSURE RANGERS (SERVICE WATER SIZING CALCULATIONS FORM) 32.0 3.0 SIZINGTOTAL 10.0 213 214 F/U F/U F/U F/U F/U 10 IN. GPM <200 46-60 FT. PSI <150 FT. WATER REQUIREMENT 246 TOTAL DEMAND. 2.0 FD-1 FLOOR DRAIN ZURN Z415B-5-P DURA-COATED CAST IRON BODY "TYPE B" POLISHED NICKEL BRONZE, LIGHT DUTY SANI-GARD AUTOMATIC TRAP PRIMER ZURN Z1022 ALL BRONZE BODY W/ INTEGRAL VACUUM SANI-GARD TRAP PRIMER TO BE INSTALLED IN STRAINER RESTROOM 2-1/2"F/U 4 2.0 SIZE 1-1/2" REQUIREMENTS DESCRIPTION WASTE TRAP VENTS C.W.H.W. WATER 3"INT.2"1/2"- LAVATORY 2"1-1/2"1/2"1/2"1-1/2" SINKS 2"1-1/2"1/2"1/2" MOP SINK 1-1/2"2"1-1/2"1/2"1/2" FIXTURE PIPING PLUMBING LEGEND NEW SEWER LINE NEW HOT WATER LINE HOT WATER STUB COLD WATER STUB VENT PIPE CLOSET NEW WALL CLEAN-OUT TABLE 5.303.2.3.1 FIXTURE FLOW RATE FIXTURE TYPE FLOW RATE MAXIMUM FLOW RATE AT 20% REDUCTION LAVATORY FAUCETS- NON RESIDENTIAL GRAVITY TANK TYPE WATER CLOSETS URINALS 0.5 GPM @ 60 PSI 1.28 GALLONS/FLUSH 0.5 GPF(FLOOR MOUNTED) OR 0.35 GPM @ 60 PSI 1.12 GALLONS/FLUSH 0.44 OR .11 GALLONS/FLUSH METERING FAUCETS 0.20 GALLONS/CYCLE .125 GPF (WALL MOUNTED) 0.18 GALLONS/CYCLE FS-1 FLOOR SINK ZURN Z-1900-2NH 2" WASTE OR EQUAL HS-1 HAND SINK NSF APPROVED 4CS-1 SS BAR SINK 4-COMPARTMENT 16 GA. 304-SERIES NSF APPROVED STAINLESS STEEL ADVANCE TABCO FC-4-1010-18RL OR EQUAL 2.0(E)HAND SINKS 3.0(E)3-COMP. SINK 2.0(E)PREP SINK 3.0(E)MOP SINK 2.0(E)URINALS1 1 2 1 1 4.0 3.0 3.0 (N)HORIZONTAL DRAIN LINES (N)HORIZONTAL DRAIN LINES EXISTING SEWER LINE (E)2" FD-1 OR EQUAL FS-1 FS-1 FS-1 EXISTING REGENCY HS-1 4CS-1 HS-2 HAND SINK STAINLESS STEEL NSF APPROVED NEW REGENCY 304 STAINLESS STEEL600B11014 2" WASTE HS-2 OR EQUAL 2.0(N)HAND SINK1 2.0 3.0(N)4-COMP.BAR SINK1 3.0 09/15/2020 NO. DATE REVISIONS PROJECT: AN INDUSTRIAL BUILDING FOR: LA QUINTA BREWING COMPANY LA QUINTA, CA. 92253 TITLE SHEET NO. OF: DATE AUG. 2020 DRN. BY R.G. SCALE AS NOTED APPROVED Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com 78-100 MAIN ST. SUITES 101 & 103 1. 09/14/20 PLAN CHECK CORRECTIONS P2 PLUMBING PLAN (E)F.D. (E)F.D. (E)FLR SINK (E)3-COMP SINK (E)ICE MACHINE (E)MOP SINK (E)WH 100 GAL (E)PREP SINK (E)HAND SINK (E)FLR SINK (E)FLR SINK (E)HAND SINK (E)WATER LINES (E)WATER LINE CONNECTION. EXTEND NEW LINES TO NEW LOCATIONS (N)1/2" CW (N)1/2"HW P.O.C. EXTEND NEW COLD & HOT LINES TO NEAREST LOCATION FD-1 (E)4"S W R . (E)4"S W R . (E ) V N T . (N ) 2 " S W R . (N) 2 " S W R . (N)FS-1 (E)FLOOR SINK (N ) 2 " V N T . (N)2"V N T(N)2"V N T (N ) 2 " V N T . (N ) 2 " V N T . (E) 2 " S W R . (E)FLOOR DRAIN (E)2"S W R . (E ) V N T . (N) VENTS TO EXISTING (E ) V N T . (N)FS-1 (N)FD-1 (N)2"SWR. (N)FS-1(N ) 2 " V N T . (N)2"V N T (N)2"VNT (E)VENT TO ROOF 09/15/2020