Loading...
FA2023-0003BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 05/01/2023 ISSUED DATE: 10/09/2023 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Fire Alarm/Monitoring System 78720 HIGHWAY 111 FA2023-0003 643220024 $2,000.00 Owner:Don Merritt PO Box 5164, Hemet, CA 92544 Applicant:Don Merritt PO Box 5164, Hemet, CA 92544 Contractor:Don Merritt / 765526 PO Box 5164, Hemet, CA 92544 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 5/16/25 9:55 am Page 1 of 3 Permit Type: Permit Number: Property Address: Fire Alarm/Monitoring System FA2023-0003 78720 HIGHWAY 111 BUILDING PERMIT PETCO - FIRE PANEL REPLACEMENT *** Use of Permit Construction Details M: Stores, Markets, Gas Station Building/Unit Occupancy Classification(s) SEE PLANSCalculated Occupancy Load SEE PLANSFire Alarm System - Monitoring Company Name SEE PLANSMonitoring Company Address SEE PLANSMonitoring Company Phone Number Central Supervising StationSupervising Station Type Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00000209 $250.00 FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS PC $250.00 $8.00 TECHNOLOGY ENHANCEMENT FEE $8.00 $10.90 Credit Card Convenience Fee $10.90 $11.00 RECORDS MANAGEMENT FEE $11.00 $167.00 FIRE SPRINKLER SYSTEMS SUPERVISION AND ALARMS $167.00 $446.90 $446.90 Total for Invoice INV-00000209 Grand Total for Permit $446.90 $446.90 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Review v.1 08/29/2023 7:24 Fire Review v.1 Receive Submittal 08/29/2023 7:24 Inspections v.1 01/23/2024 11:52 01/31/2024 16:15 Fire Alarm Monitoring - Function v.1 Inspection 01/23/2024 11:52 01/31/2024 16:12 Fire Alarm Rough Wire v.1 Inspection 01/23/2024 0:00 01/31/2024 16:14 Fire Alarm Final v.1 Inspection 01/23/2024 11:54 01/31/2024 16:15 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections Printed: 5/16/25 9:55 am Page 2 of 3 Permit Type: Permit Number: Property Address: Fire Alarm/Monitoring System FA2023-0003 78720 HIGHWAY 111 BUILDING PERMIT A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 5/16/25 9:55 am Page 3 of 3 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org May 30, 2023 Complete Services PO Box 5164 Hemet, CA 92544 Re: Monitoring Fire Alarm System - REPLACEMENT Plan Review – PETCO FA2023-0003 / 78720 HIGHWAY 111, LA QUINTA, CA 92253 The fire alarm system plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1. For Central Station monitoring service, provide written documentation, at the time of acceptance testing, that there is a contract to provide the runner and maintenance services as required per NFPA 72. 2. The Office of the Fire Marshal staff shall witness the following inspections/tests: a) Rough-Wire Inspection – all wire not in conduit is exposed for inspection. b) Function Test / Final Acceptance Testing and Certification 3. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. 4. Operating, testing, and maintenance instructions, record drawings (“as builds”), site-specific software and equipment specifications shall be provided in a documentation cabinet in compliance with NFPA 72 Section 7.7.2 The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 78720 HIGHWAY 111 PERMIT#: FA2023-0003 DATE ISSUED: 5/30/2023 DESCRIPTION: PETCO – FACP CHANGEOUT CONTRACTOR: COMPLETE SERVICES HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 2500 Maitland Center Parkway Suite 105 Maitland, FL 32751 T: 866-608-3286 F: 407-475-1115 www.vectorsecurity.com Vector Security is a registered trademark of Vector Security, Inc. Licenses: AK 09-017; AL AESBL 11-817, 44814; AR E 2005 0104; AZ ROC218982; CA ACO 6152, 914676; DE 1989004898; FL EF20000395; HI C 27082; LA F 317, 54974; MA 1594 C; NC 2313-CSA; ND 37153; NJ , 13VH00292300, Fire Alarm, Burglar Alarm and Locksmith Business Lic. # 34AL00000400; NV F 437, 0066031; NY 12000234360; OH 53-50-1081; OK 559; PA PA004997; RI 30394, AFC-0449; TN 0444, 1341, 1551, 1552; TX B11645; UT 4759383-6501; VA DCJS #11- 2048; WA VECTOSI957PE; WV WV043469. Additional license information available at www.vectorsecurity.com. April 26, 2023 Desert Office 77-933 Las Montanas Rd. # 201 Palm Desert, CA 92211 Re: Petco #1152 78720 HWY 111 La Quinta CA 92253 Fire Sprinkler Monitoring Upgrade This scope letter serves to inform you that the above listed Petco store, is installing and testing an upgraded sprinkler monitoring system within an existing Petco retail store. The system shall be monitored by an approved listed monitoring station. The communication paths will be dual path pots. If you have any questions or concerns, please call Carla Intriago at 866-608-3286 or email NADFire_Engineering@vectorsecurity.com at your earliest convenience. Upon approval our local contractor will apply for permit and pay any fees due. Thank you, Carla Intriago Carla Intriago Fire Engineering Coordinator Vector Security ENGINEER OF RECORD Jeremiah Mundell 2500 MAITLAND CTR PKWY SUITE 105 703-468-6100 NADFireEngineering@ vectorsecurity.com Jeremiah Mundell, SET 132057 FIRE ALARM SYSTEMS LEVEL IV Date: 04/12/2023 SUPPLEMENTARY REQUIRED FIRE SAFETY CONTROL SYSTEM OUTPUTS AC T U A T E C O M M O N A L A R M S I G N A L I N D I C A T O R AC T U A T E A U D I B L E A L A R M S I G N A L AC T U A T E C O M M O N S U P E R V I S O R Y S I G N A L I N D I C A T O R AC T U A T E A U D I B L E S U P E R V I S O R Y S I G N A L AC T U A T E C O M M O N T R O U B L E S I G N A L I N D I C A T O R AC T U A T E A U D I B L E C O M M O N T R O U B L E S I G N A L AC T U A T E H O R N S & S T R O B E S T H R O U G H O U T F A C I L I T Y DI S P L A Y C H A N G E O F S T A T U S TR A N S M I T F I R E S I G N A L T O S U P E R V I S I N G S T A T I O N TR A N S M I T S U P E R V I S O R Y S I G N A L T O S U P E R V I S I N G S T A T I O N TR A N S M I T T R O U B L E S I G N A L T O S U P E R V I S I N G S T A T I O N NO T U S E D HV A C S H U T D O W N P R O C C E S S AC T U A T E N O T I F I C A T I O N A T F . D . R E S P O N S E P O I N T NO T U S E D NO T U S E D SYSTEM INPUTS A B C D E F G H I J K L M N O P 1 FIRE ALARM SYSTEM AC POWER FAILURE ••••1 2 FIRE ALARM SYSTEM LOW BATTERY ••••2 3 OPEN CIRCUIT ••••3 4 GROUND FAULT ••••4 5 NOTIFICATION APPLIANCE SHORT CIRCUIT ••••5 6 COMMINCATION LOSS ••••6 7 FIRE ALARM SYSTEM PULL STATIONS •••••7 8 SMOKE DETECTORS •••••8 9 IN-DUCT SMOKE DETECTORS ••••I 9 10 WATERFLOW ••••••10 11 SPRINKLER CONTROL VALVE ••••11 A B C D E F G H I J K L M N O P I-INDIVIDUAL HVAC SHUTDOWN CONTROL UNIT ANNUNCIATION NOTIFICATION DUALPATH POTS DEDICATED 120V 20 AMP CIRCUIT H N G FIRE ALARM CONTROL PANEL S D001 AIM AIM AIM AIM AIM AIM M002 F M005 AIM M003 ANNUNCIATOR N1•01 EOL 75cd WP N2•01 EOL 75cd C RTU #4 M014S RTU #3 M013S RTU #2 M012S RTU #5 M015S RTU #1 M011S POINT LIST MODULE ADDRESSES M## Device Label Location M001 M002 WATERFLOW M003 PIV M004 M005 MAIN ENTRY PULL M006 M007 M008 M009 M010 M011 RTU#1 DUCT SMOKE M012 RTU#2 DUCT SMOKE M013 RTU#3 DUCT SMOKE M014 RTU#4 DUCT SMOKE M015 RTU#5 DUCT SMOKE POINT LIST DETECTOR ADDRESSES D## Device Label Location D001 FACP SMOKE PANEL SK6820 (6820 (SK)) BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) STANDBY CURRENT (AMPS)SECONDARY ALARM CURRENT (AMPS) PANEL COMPONENTS QTY PART NO.DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 6820 MAIN BOARD FIRE ALARM CONTROL PANEL MAIN BOARD SK PROTOCOL 0.215 0.215 0.385 0.385 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) SK6820•ANN 1 5860R ANNUNCIATOR 0.02 0.02 0.025 0.025 SK6820•N1 1 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 0 0 0.176 0.176 SK6820•N2 1 PC2RL 2-Wire, Horn Strobe, Red 75cd 0 0 0.143 0.143 SK6820•SLC 7 SK-MONITOR ADDRESSABLE MONITOR MODULE 0.000375 0.002625 0.000375 0.002625 1 SK-PHOTO ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 0.0003 0.0003 0.0003 0.0003 1 SK-PULL-DA ADDRESSABLE MANUAL PULL STATION, DOUBLE-ACTION 0.000375 0.000375 0.000375 0.000375 TOTAL STANDBY (A)0.2383 TOTAL ALARM (A)0.7323 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A)0.2383 24 5.72 SECONDARY ALARM LOAD (A)0.7323 0.08 0.06 STANDBY AND ALARM SUBTOTAL (AMP HOURS)5.78 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)6.94 PROVIDE (2) 12V 7AH BATTERIES *BATTERY BOX SIZE CAPACITY NOT SPECIFIED. REFER TO MANUFACTURER DOCUMENTATION. FAA WP C AIM S F SK6820 N1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.18 Min. Operational Voltage:16 End Of Line Voltage:20.22 Max. Circuit Current (A):3 Voltage Drop Percent:0.87 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.176 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):165 Spare Current (A):2.824 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.010918 Spare Current (A) Percent:94.13 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP SK6820 N2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.17 Min. Operational Voltage:16 End Of Line Voltage:20.23 Max. Circuit Current (A):3 Voltage Drop Percent:0.83 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.143 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):193 Spare Current (A):2.857 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.182683 Spare Current (A) Percent:95.23 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) PC2RL 2-Wire, Horn Strobe, Red 75cd 1 0.143 0.143 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) C NOTES 1.A MICROPROCESSOR-BASED MULTIPLEX FIRE ALARM SYSTEM WITH INTELLIGENT, ADDRESSABLE INITIATION DEVICES WILL BE REQUIRED. THE RISER DIAGRAM IS BASED AROUND A MULTIPLEX ADDRESSABLE SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MONITORED BY AN APPROVED CENTRAL STATION MONITORING SERVICE. INTERFACE EQUIPMENT WILL BE FULLY UL LISTED AND FM APPROVED FOR THIS PURPOSE. 2.SIGNALING LINE CIRCUITS SHALL BE CLASS B, STYLE 4 MINIMUM. INITIATING DEVICE CIRCUITS SHALL BE CLASS B, STYLE B MINIMUM. NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B, STYLE Y MINIMUM. 3.OUTDOOR DEVICES (WHEN REQUIRED) SHALL BE MOUNTED ON CAST WEATHERPROOF OUTLET BOXES (2 GANG BELL BOX). 4.ALL FIRE ALARM CABLING SHALL BE ROUTED THROUGH CONDUIT FROM DEVICES TO BOTTOM OF THE BAR JOIST. AT THAT POINT CABLING SHALL BE RUN EXPOSED ALONG THE CEILING IF ACCEPTABLE BY THE AHJ. 5.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LINE VOLTAGE (120 V. MAX.) IN SEPARATE CONDUIT. SHALL BE INSTALLED PER NEC UNLESS OTHERWISE NOTED BY LOCAL AUTHORITIES. 6.ALL EXPOSED CABLE BELOW THE BOTTOM OF THE BAR JOIST, OTHER ROOF STRUCTURE OR OTHER LOCATIONS WHERE THE CABLE MAY BECOME EXPOSED AND/OR DAMAGED, MUST BE INSTALLED WITHIN A STEEL CONDUIT. ALL SPLICES SHALL BE TERMINATED IN A BOX MARKED AS SPLICE POINT. 7.SYSTEM OPERATION, TESTING, TURN OVER, WARRANTY, COMPLIANCE, AND AFTER MARKET SERVICE SHALL BE PROVIDED BY THE FIRE ALARM CONTRACTOR. 8.VECTOR SECURITY SHALL NOT BE RESPONSIBLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY VECTOR SECURITY. 9.ALL CONDUIT, BOXES (UNLESS OTHERWISE INDICATED), FITTINGS, COUPLINGS, CONNECTORS, STRAPS, SUPPORTS, PULL-LINES, BUSHINGS, ETC. SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. ALL WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF NFPA 70. 10.ALL CONDUIT AND BACK BOX SIZES SHALL BE COORDINATED WITH THE FIRE ALARM CONTRACTOR. 11.ALL CONDUIT SHALL BE STUBBED UP TO BOTTOM OF BAR JOIST. 12.NO HORIZONTAL RUNS ON WALLS WILL BE ALLOWED BELOW THE BAR JOIST. 13.LOOSE WIRE SHALL BE INSTALLED AND SECURED TO THE UPPER LEVEL OF THE BAR JOIST AND SHALL RUN EITHER PARALLEL OR AT 90° TO THE JOIST. NO DIAGONAL WIRING WILL BE ALLOWED. 14.THE INSTALLATION CONTRACTOR SHALL COORDINATE ALL LOCATIONS WITH THE LATEST FIXTURE PLANS PRIOR TO INSTALLATION. 15.ALL NOTIFICATION APPLIANCES SHALL BE SYNCHRONIZED PER NFPA 72. 16.AUDIBLE EVACUATION SIGNAL SHALL BE TEMPORAL 3 PER NFPA 72. 17.A SYSTEM RECORD DOCUMENT BOX SHALL BE INSTALLED PER NFPA 72. 18.FIRE ALARM BREAKER SHALL BE LOCKED UP AND LABELED. 19. FIRE ALARM CONTROL PANEL OPERATING CONTROLS SHALL NOT BE MORE THAN 72”ABOVE THE FINISHED FLOOR LEVEL. INDEX OF DRAWINGS DEVE DETAILS SPRINKILER MONITORING LAYOUT SYSTEM CALCULATIONS TITLE SHEET, GENERAL NOTES, SYSTEM RISER DIAGRAM AND FA-2 FA-1 FA-0 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION & TESTING OF AN UPGRADE SPRINKLER MONITORING SYSTEM WITHIN AN EXTSTING PETCO RETAIL STORE. THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED MONITORING STATION. THE COMMUNICATION PATHS WILL BE DUAL PATH POTS. PROJECT INFORMATION NAME OF PROJECT: ADDRESS: PROPOSED USE: FIRE ALARM VENDOR: FIRE ALARM DESIGNER: FIRE ALARM MONITORED BY: INSTALLING CONTRACTOR NAME OF CONTRACTOR LICENSE NUMBER: PETCO 1152 78720 HWY 111 LA QUINTA, CA 92253 RETAIL VECTOR SECURITY 13555 WELLINGTON CENTER CIRCLE SUITE 123 GAINESVILLE, VA 20155 JOEY MESSER VECTOR SECURITY 2500 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 VECTOR SECURITY 2000 ERICSSON DR. WARRENDALE, PA 15086 TBD (888) 832-8671 (703) 468-6100 EXT. 52519 724-741-2200 UL# S2535 APPLICABLE BUILDING CODES BUILDING FIRE ELECTRICAL NFPA72 MECHANICAL OTHER OTHER CODES 2022 CBC 2022 CFC 2022 CEC 2022 2022 CMC AMMENDMENTS SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION & TESTING OF AN UPGRADE SPRINKLER MONITORING SYSTEM WITHIN AN EXTSTING PETCO RETAIL STORE. THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED MONITORING STATION. THE COMMUNICATION PATHS WILL BE DUAL PATH POTS. PROJECT INFORMATION NAME OF PROJECT: ADDRESS: PROPOSED USE: FIRE ALARM VENDOR: FIRE ALARM DESIGNER: FIRE ALARM MONITORED BY: INSTALLING CONTRACTOR NAME OF CONTRACTOR LICENSE NUMBER: PETCO 1152 78720 HWY 111 LA QUINTA, CA 92253 RETAIL VECTOR SECURITY 13555 WELLINGTON CENTER CIRCLE SUITE 123 GAINESVILLE, VA 20155 JOEY MESSER VECTOR SECURITY 2500 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 VECTOR SECURITY 2000 ERICSSON DR. WARRENDALE, PA 15086 TBD (888) 832-8671 (703) 468-6100 EXT. 52519 724-741-2200 UL# S2535 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION & TESTING OF AN UPGRADE SPRINKLER MONITORING SYSTEM WITHIN AN EXTSTING PETCO RETAIL STORE. THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED MONITORING STATION. THE COMMUNICATION PATHS WILL BE DUAL PATH POTS. PROJECT INFORMATION NAME OF PROJECT: ADDRESS: PROPOSED USE: FIRE ALARM VENDOR: FIRE ALARM DESIGNER: FIRE ALARM MONITORED BY: INSTALLING CONTRACTOR NAME OF CONTRACTOR LICENSE NUMBER: PETCO 1152 78720 HWY 111 LA QUINTA, CA 92253 RETAIL VECTOR SECURITY 13555 WELLINGTON CENTER CIRCLE SUITE 123 GAINESVILLE, VA 20155 JOEY MESSER VECTOR SECURITY 2500 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 VECTOR SECURITY 2000 ERICSSON DR. WARRENDALE, PA 15086 TBD (888) 832-8671 (703) 468-6100 EXT. 52519 724-741-2200 UL# S2535 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION & TESTING OF AN UPGRADE SPRINKLER MONITORING SYSTEM WITHIN AN EXTSTING PETCO RETAIL STORE. THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED MONITORING STATION. THE COMMUNICATION PATHS WILL BE DUAL PATH POTS. PROJECT INFORMATION NAME OF PROJECT: ADDRESS: PROPOSED USE: FIRE ALARM VENDOR: FIRE ALARM DESIGNER: FIRE ALARM MONITORED BY: INSTALLING CONTRACTOR NAME OF CONTRACTOR LICENSE NUMBER: PETCO 1152 78720 HWY 111 LA QUINTA, CA 92253 RETAIL VECTOR SECURITY 13555 WELLINGTON CENTER CIRCLE SUITE 123 GAINESVILLE, VA 20155 JOEY MESSER VECTOR SECURITY 2500 MAITLAND CENTER PARKWAY MAITLAND, FL 32751 VECTOR SECURITY 2000 ERICSSON DR. WARRENDALE, PA 15086 TBD (888) 832-8671 (703) 468-6100 EXT. 52519 724-741-2200 UL# S2535 SYSTEM RISER DIAGRAM DATE SHEET REVISIONS FA-0 SHEET NO.1 04/12/2023 THIS DRAWING AND DESIGNS SHALL NOT BE DUPLICATED, USED, OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT WRITTEN CONSENT OF VECTOR SECURITY, INC REPRODUCTIONS SHALL BEAR THIS NOTICE. PE T C O 1 1 5 2 78 7 2 0 H W Y 1 1 1 LA Q U I N T A , C A 9 2 2 5 3 FI R E S P R I N K L E R M O N I T O R I N G U P G R A D E DRAWN BY JAM SUBMITTALS PREPARED BY VECTOR SECURITY NETWORKS 2500 MAITLAND CTR PKWY SUITE 105 MAITLAND, FL 32751 703-468-6100 SYSTEM INPUT/OUTPUT MATRIX SYSTEM ANNUNCIATION PANEL BATTERY CALCULATIONS AND VOLTAGE LOSS ENGINEER OF RECORD Jeremiah Mundell 2500 MAITLAND CTR PKWY SUITE 105 703-468-6100 NADFireEngineering@ vectorsecurity.com Jeremiah Mundell, SET 132057 FIRE ALARM SYSTEMS LEVEL IV Date: 04/12/2023 RETAIL OPEN TO STRUCTURE VESTIBULE 12'-0" ACT CAGE RM 12'-0" ACT TUB RM 12'-0" ACT OFFICE 9'-0" ACT BREAKROOM 9'-0" ACT RESTROOM 9'-0" ACT HALLWAY 9'-0" ACT JAN. CLOSET OPEN TO STRUCTURE PRE-SALES OPEN TO STRUCTURE WORK RM 8'-0" ACT WELLNES RM 8'-0" ACT HALLWAY 9'-0" ACT RESTROOM 9'-0" ACT GROOMING RECEPTION 11'-0" ACT GROOMING SALON 12'-0" ACT ADOPTION 11'-0" ACT 20 4 8 16 32 FEET SCALE:1/8"=1'-0" FACP DOC S D001 S RTU-1 EX AIM M011 EX S RTU-2 EX AIM M012 EX S RTU-4 EX AIM M014 EX S RTU-3 EX AIM M013 EX S RTU-5 EX AIM M015 EX EX EX AIM M002 AIM M003 FM005 FAA N1•01 EOL 75cd WP N2•01 EOL 75cd C 1 2 2 2 22 2 2 TO M003 PIV TO M005 PULL TO FACP TO FACP TO FACP CABLE AND WIRE LEGEND LABEL PART NO AW G RESISTANCE (Ω/KFT)CIRCUIT COLOR DESCRIPTION A 18/4 FPLP/R (SLC)18 7.77 4 COND. SOLID COPPER FPLP/R UNSHIELDED B 14/2 FPLP/R (NAC)14 3.07 2 COND. SOLID COPPER FPLP/R UNSHIELDED C 18/4 FPLP/R (ANN)18 7.77 4 COND. SOLID COPPER FPLP/R UNSHIELDED D 18/4 FPLP/R (IDC)18 7.77 4 COND. SOLID COPPER FPLP/R UNSHIELDED WIRE LEGEND DEVICE AND 1.LOCATE ABOVE FDC. 2.NEW INPUT MODULE CONNECTED TO EXISTING DEVICE. NOTES# EXISTING DEVICES SHOWN IN BLACK. ALL NEW DEVICES SHOWN IN RED. NOTES PROJECT DEVICE LEGEND SYMBOL QTY EXISTING MANUFACTURER PART NO DESCRIPTION CSFM 5 X EXISTING EXISTING DUCT SMOKE DETECTOR 1 SPACE AGE ELECTRONICS SSU00672 FIRE ALARM DOCUMENT BOX, RED 12” X 13” TALL 2 ¼ DEEP 7300-0553:0110 1 X EXISTING VALVE TAMPER SUPERVISORY SWITCH 1 SILENT KNIGHT 6820 (SK) FIRE ALARM CONTROL PANEL, ADDRESSABLE, SK PROTOCOL 7165-0559:0500 1 SILENT KNIGHT 5860R ANNUNCIATOR 7165-0559:0500 5 X EXISTING EXISTING REMOTE TEST STATION REMOTE TEST STATION 1 X EXISTING WATERFLOW SWITCH 1 SILENT KNIGHT SK-PULL-DA ADDRESSABLE MANUAL PULL STATION, DOUBLE-ACTION 7150-0559:0161 7 SILENT KNIGHT SK-MONITOR ADDRESSABLE MONITOR MODULE 7300-0559:0155 1 SILENT KNIGHT SK-PHOTO ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 7272-0559:0149 1 SYSTEM SENSOR P2RK 2-WIRE HORN STROBE, STANDARD CD, OUTDOOR 7125-1653:0188 1 SYSTEM SENSOR PC2RL 2-WIRE, HORN STROBE, RED 7135-1653:0503 S DOC FACP FAA F AIM S WP C SPRINKLER MONITORING SYSTEM LAYOUT SCALE: 1/8"=1'-0" DATE SHEET REVISIONS FA-1 SHEET NO.2 04/12/2023 THIS DRAWING AND DESIGNS SHALL NOT BE DUPLICATED, USED, OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT WRITTEN CONSENT OF VECTOR SECURITY, INC REPRODUCTIONS SHALL BEAR THIS NOTICE. PE T C O 1 1 5 2 78 7 2 0 H W Y 1 1 1 LA Q U I N T A , C A 9 2 2 5 3 FI R E S P R I N K L E R M O N I T O R I N G U P G R A D E DRAWN BY JAM SUBMITTALS PREPARED BY VECTOR SECURITY NETWORKS 2500 MAITLAND CTR PKWY SUITE 105 MAITLAND, FL 32751 703-468-6100 SCALE: SK-MONITOR MONITOR MODULE WIRING DIAGRAM N.T.S. T11 T10 T9 T8 T7 T6 LOOP ADDRESS TOP TENS ONES T1 T2 T3 T4 T5 SK-MONITOR SLC - SLC + A/B + A/B - A - A + SCALE: SK-PULL-DA/SA PULL STATION WIRING DIAGRAM N.T.S.SCALE: B300-6 DETECTOR BASE WIRING DIAGRAM N.T.S. 3'-0" MINIMUM ANNUNCIATOR MANUAL PULL 5'-0" MAXIMUM 0'-4" MINIMUM SMOKE/ HEAT MOUNT ON A BOX APPROVED EXIT DETECTOR 96" MAXIMUM TOP OF DEVICE 80" MINIMUM BOTTOM OF DEVICE 5'-6" FLOOR FINISHED STROBE CONTROL PANEL HORN/ STROBE AIR SUPPLY DIFFUSER OR RETURN AIR OPENING GRAPHIC NATIONAL ELECTRIC CODE INSTALL PER CONDUIT & VISUAL DEVICES MOUNT AUDIBLE 0'-4" MINIMUM,0'-6" MINIMUM BOXES. ON APPROVED 3'-8" (3'-6" MINIMUM, 4'-0" MAXIMUM) HINGED SIDE 1'-0" MAXIMUM STATION SCALE: NFPA 72 AND ADA DEVICE INSTALLATION REQUIREMENTS N.T.S. SCALE: DUCT DETECTOR MOUNTING INDIVIDUAL SHUTDOWN N.T.S. T11 T10 T9 T8 T7 T6 LOOP ADDRESS TOP TENS ONES T1 T2 T3 T4 T5 SK-MONITOR SLC - SLC + A/B + A/B - A - A + SCALE: SYSTEM SENSOR 2-WIRE STROBE AND HORN/STROBE APPLIANCE WIRING DIAGRAM N.T.S. + – + – INPUT FROM FACP OR PRIOR DEVICE OUTPUT TO NEXT DEVICE OR EOL DATE SHEET REVISIONS FA-2 SHEET NO.3 04/12/2023 THIS DRAWING AND DESIGNS SHALL NOT BE DUPLICATED, USED, OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT WRITTEN CONSENT OF VECTOR SECURITY, INC REPRODUCTIONS SHALL BEAR THIS NOTICE. PE T C O 1 1 5 2 78 7 2 0 H W Y 1 1 1 LA Q U I N T A , C A 9 2 2 5 3 FI R E S P R I N K L E R M O N I T O R I N G U P G R A D E DRAWN BY JAM SUBMITTALS PREPARED BY VECTOR SECURITY NETWORKS 2500 MAITLAND CTR PKWY SUITE 105 MAITLAND, FL 32751 703-468-6100 SCALE: N.T.S. DETAILS DEVICE ENGINEER OF RECORD Jeremiah Mundell 2500 MAITLAND CTR PKWY SUITE 105 703-468-6100 NADFireEngineering@ vectorsecurity.com Jeremiah Mundell, SET 132057 FIRE ALARM SYSTEMS LEVEL IV Date: 04/12/2023