BCOM2024-0157 - Energy ReportBUILDING ENERGY ANALYSIS REPORT
PROJECT:
Project Designer:
Report Prepared by:
Job Number:
Date:
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC – www.energysoft.com.
DAISO
2712 Loker Avenue West #1063
15 Hubble # 200
Irvine, CA 92618
JAG Architecture
Pro Engineering
Ray Parsi
949-752-9333
La Quinta, CA 92253
11/5/2024
24490
Carlsbad, CA 92010
(949)-842-2199
78870 CA-111
12/10/2024
BCOM2024-0157
SHELL IMPROVEMENT IN
ANTICIPATION OF NEW
TENANT
[VB/M-OCC/124-OL/SPRINK
LED] THIS PERMIT DOES
NOT INCLUDE T-BAR
CEILING OR INSTALLATION
OF GENERAL LIGHTING.
2022 CALIFORNIA
BUILDING CODES.
TABLE OF CONTENTS
3
1
Table of Contents 2
Form NRCC/LMCC-PRF-E Certificate of Compliance
Cover Page
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 1 of 14)
Project Name: Nonresidential Building Date Prepared: 2024-11-05
A. General Information
1 Project Name Nonresidential Building
2 Run Title Title 24 Analysis
3 Project Location 78870 CA-111
4 City La Quinta 5 Standards Version Compliance 2022
6 Zip code 92253 7 Compliance Software (version)EnergyPro 9.3
8 Climate Zone 15 9 Building Orientation (deg)135
10 Building Type(s)• Nonresidential 11 Weather File PALM-SPRINGS_STYP20.epw
12 Project Scope • Existing alteration 13 Number of Dwelling Units 0
14 Total Conditioned Floor Area in
Scope (ft2)7601 15 Total # of hotel/motel rooms 0
16 Total Unconditioned Floor
Area (ft2)0 17 Fuel Type Natural gas
18 Nonresidential Conditioned
Floor Area 7601 19 Total # of Stories (Habitable
Above Grade)1
20 Residential Conditioned Floor
Area 0
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 2 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
B. PROJECT SUMMARY
Table B shows which building components are included in the performance calculation. If indicated as not included, the project must show compliance prescriptively if within the
permit application.
Building Components Complying via Performance Building Components Complying Prescriptively
Envelope (See Table G)
Nonres Performance Solar Thermal Water
Heating (See Table I3)
Performance The following building components are ONLY eligible for prescriptive compliance
and should be documented on the NRCC form listed if within the scope of the
permit application (i.e. compliance will not be shown on the NRCC-PRF-E).MultiFam Not Included Not Included
Mechanical (See Table H)
Nonres Performance Covered Process:
Commercial Kitchens (see
Table J)
Performance Indoor Lighting (Unconditioned) 140.6 &
170.2(e)
NRCC-LTI-E is
required
MultiFam Not Included Not Included Outdoor Lighting 140.7 & 170.2(e)NRCC-LTO-E is
required
Domestic Hot Water (See
Table I)
Nonres Performance Covered Process:
Laboratory Exhaust (see
Table J)
Performance Sign Lighting 140.8 & 170.2(e)NRCC-LTS-E is
required
MultiFam Not Included Not Included Building Components Complying with Mandatory Measures
Lighting (Indoor Conditioned,
see Table K)
Nonres Not Included
Photovoltaics (see Table
F)
Performance
Electrical power systems, commissioning, solar ready, elevator and
escalator requirements are mandatory and should be documented
on the NRCC form listed if applicable (i.e. compliance will not be
shown on the NRCC-PRF-E.)
MultiFam Not Included Not Included Electrical Power Distribution 110.11 NRCC-ELC-E is
required
Battery (see Table F)
Performance Commissioning 120.8 NRCC-CXR-E is
required
Not Included Solar and Battery 110.10 NRCC-SAB-E is
required
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 3 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
C1. COMPLIANCE SUMMARY
COMPLIES3
Time Dependent Valuaton (TDV)Source Energy Use
Efficiency1 (kBtu/ft2 - yr)Total2 (kBtu/ft2 - yr)Total2 (kBtu/ft2 - yr)
Standard Design 519.18 n/a n/a
Proposed Design 471.67 n/a n/a
Compliance Margins 47.51 n/a n/a
Pass n/a n/a
1 Efficiency measures include improvements like a better building envelope and more efficient equipment
2 Compliance Totals include efficiency, photovoltaics and batteries
3 New Construction, Complete Addition Scope: Building complies when all efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits
are not exceeded
Existing, Addition and Alteration Scope: Building complies when efficiency compliance margin is greater than or equal to zero and unmet load hour limits are not exceeded
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 4 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
C2. TDV ENERGY COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2 - yr)
COMPLIES2
Energy Component Standard Design (TDV)Proposed Design (TDV)Compliance Margin (TDV)1
Space Heating 9.93 4.08 5.85
Space Cooling 277.83 256.89 20.94
Indoor Fans 130.77 110.33 20.44
Heat Rejection 0 0 0
Pumps & Misc.0 0 0
Domestic Hot Water 15.35 15.07 0.28
Indoor Lighting 85.3 85.3 0
Flexibility ---------
EFFICIENCY COMPLIANCE TOTAL 519.18 471.67 47.51 (9.2%)
Photovoltaics ---------
Batteries ---------
TOTAL COMPLIANCE 519.18 471.67 47.51 (9.2%)
1 Notes: This number in parenthesis following the Compliance Margin in column 4, represents the Percent Better than Standard.
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 5 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
C3. TDV ENERGY RESULTS FOR NON-REGULATED COMPONENTS1
Non-Regulated Energy Component Standard Design (TDV)Proposed Design (TDV)Compliance Margin (TDV)1
Receptacle 94.36 94.36 ---
Process ---------
Other Ltg ---------
Process Motors ---------
TOTAL (TOTAL COMPLIANCE + NON-REGULATED COMPONENTS)613.54 566.03 47.51 (7.7%)
1 Notes: This table is not used for Energy Code Compliance.
C6. 'ABOVE CODE' QUALIFICATIONS
This project is pursuing CalGreen Tier 1 This project is pursuing CalGreen Tier 2
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 6 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
C7. ENERGY USE SUMMARY
Energy Component Standard Design Site
(MWh)
Proposed Design Site
(MWh)
Margin
(MWh)
Standard Design Site
(MBtu)
Proposed Design Site
(MBtu)
Margin
(MBtu)
Space Heating ---0.9 ---26.2 ------
Space Cooling 59.6 54.7 4.9 ---------
Indoor Fans 33.5 30.8 2.7 ---------
Heat Rejection ------------------
Pumps & Misc.------------------
Domestic Hot Water 4.4 4.3 0.1 ---------
Indoor Lighting 25 25 0 ---------
Flexibility ------------------
EFFICIENCY TOTAL 122.5 115.7 6.8 26.2 0 26.2
Photovoltaics ------------------
Batteries ------------------
ENERGY USE SUBTOTAL 122.5 115.7 6.8 26.2 0 26.2
Receptacle 27.6 27.6 0 ---------
Process ------------------
Other Ltg ------------------
Process Motors ------------------
ENERGY USE TOTAL 150.1 143.3 6.8 26.2 0 26.2
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 7 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
C8. ENERGY USE INTENSITY (EUI)
Standard Design (kBtu/ft2 / yr)Proposed Design (kBtu/ft2 / yr)Margin (kBtu/ft2 / yr)Margin Percentage
GROSS EUI1 70.83 64.33 6.5 9.18
NET EUI1 70.83 64.33 6.5 9.18
1 Notes: Gross EUI is Energy Use Total (not including PV)/Total Building Area. Net EUI is Energy Use Total (including PV)/Total Building Area.
D1. EXCEPTIONAL CONDITIONS
• The project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary
Daylit Control requirements are met. PRESCRIPTIVE COMPLIANCE documentation (form NRCC-LTI-02-E) for the requirements of section 140.6(d) Automatic Daylighting Controls
in Secondary Daylit Zones is required.
• The proposed building includes HVAC components that do not meet the mandatory efficiency requirements.
• The user model includes space(s) that are designed to be served by mechanical cooling systems, but the cooling systems were not included in the simulation model. A cooling
system has been modeled for both the proposed and standard cases.
• The user model includes space(s) without sufficient cooling equipment. Cooling equipment has been added to the model to meet cooling loads.
G1. ENVELOPE GENERAL INFORMATION (conditioned spaces only)
01 02 03 04
Opaque Surfaces & Orientation Total Gross Surface Area (ft2)Total Fenestration Area (ft2)Window to Wall Ratio (%)
North-Facing1 585 0 0
East-Facing2 1275 1033 81.02
South-Facing3 1454 0 0
West-Facing4 990 0 0
Notes
1North-Facing is oriented to within 45 degrees of true north, including 45 00'00" east of north (NE), but excluding 45 00'00" west of north (NW),
2East-Facing is oriented to within 45 degrees of true east, including 45 00'00" south of east (SE), but excluding 45 00'00" north of east (NE),
3South-Facing is oriented to within 45 degrees of true south, including 45 00'00" west of south (SW), but excluding 45 00'00" east of south (SE),
4West-Facing is oriented to within 45 degrees of true west, including 45 00'00" north of west (NW), but excluding 45 00'00" south of west (SW),
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 8 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
G1. ENVELOPE GENERAL INFORMATION (conditioned spaces only)
01 02 03 04
Opaque Surfaces & Orientation Total Gross Surface Area (ft2)Total Fenestration Area (ft2)Window to Wall Ratio (%)
Total 4304 1033 24
Roof 7601 0 0
Notes
1North-Facing is oriented to within 45 degrees of true north, including 45 00'00" east of north (NE), but excluding 45 00'00" west of north (NW),
2East-Facing is oriented to within 45 degrees of true east, including 45 00'00" south of east (SE), but excluding 45 00'00" north of east (NE),
3South-Facing is oriented to within 45 degrees of true south, including 45 00'00" west of south (SW), but excluding 45 00'00" east of south (SE),
4West-Facing is oriented to within 45 degrees of true west, including 45 00'00" north of west (NW), but excluding 45 00'00" south of west (SW),
G4. NONRESIDENTIAL AIR BARRIER
01 02
Building Story Name Air Barrier
Com-Floor 1 No air barrier
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 9 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
G5. OPAQUE SURFACE ASSEMBLY SUMMARY
01 02 03 04 05 06 07 08 09 10
Surface Name Construction
Type Area (ft2)Framing
Type
Cavity
R-Value
Continuous R-Value
Units Value Description of Assembly Layers Status1
Interior Exterior
(ALT) 8 CMU
Wall8 Exterior Wall 1,275 N/A 0 N/A N/A U-factor 0.3794 Concrete - Part Grouted and Empty - 125
lb/ft3 - 8 in.A
8 CMU Wall12 Exterior Wall 3,029 N/A 0 N/A N/A U-factor 0.3794 Concrete - Part Grouted and Empty - 125
lb/ft3 - 8 in.E
8 CMU Wall121 Interior Wall 924 N/A 0 N/A N/A U-factor 0.3179 Concrete - Part Grouted and Empty - 125
lb/ft3 - 8 in.E
Slab On
Grade19
Underground
Floor 7,601 N/A 0 N/A N/A F-factor 0.73
Slab Type =Unheated slab on grade
Insulation Orientation =None
Insulation R-Value =none
E
(E) 4 CONCRETE
ROOF21 Roof 7,601 Wood 0 N/A N/A U-factor 0.4806
Built-up roofing - 3/8 in.
Plywood - 1/2 in.
Composite-1
Concrete - 140 lb/ft3 - 4 in.
E
1 Status: N - New, A - Altered, E - Existing
G6A. OPAQUE DOOR SUMMARY (NONRESIDENTIAL)
01 02 03 04
Assembly Name Area (ft2)Overall U-factor Status1
Insulated Door15 21 0.2 E
1 Status: N - New, A - Altered, E - Existing
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 10 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
G7A. FENESTRATION ASSEMBLY SUMMARY (NONRESIDENTIAL)
01 02 03 04 05 06 07 08 09
Fenestration
Assembly Name Fenestration Type/ Product Type / Frame Type Certification
Method1 Assembly Method Area
(ft2)
Overall
U-factor Overall SHGC Overall VT Status2
(E) Cooling
Vertical fenestration
Fixed window
N/A
NFRC Manufactured 899 0.3 0.23 0.5 E
Cooling
Vertical fenestration
Fixed window
N/A
NFRC Manufactured 134 0.3 0.23 0.5 N
1 Notes: Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.6-A and Table 110.6-B. Center of Glass (COG)
values are for the glass-only, determined by the manufacturer, and are shown for ease of verification. Site-built fenestration values are calculated per Nonresidential Appendix
NA6 and are used in the analysis.
2 Status: N - New, A - Altered, E - Existing
H1. DRY SYSTEM EQUIPMENT (FURNACES, AIR HANDLING UNITS, HEAT PUMPS, VRF, ECONOMIZERS ETC.)
01 02 03 04 05 06 07 08 09 10 11 12
Equipment Name Equipment Type Qty
Heating Cooling
Economizer
Type (if
present)
Status1Total
Heating
Output
(kBtu/h)
Supp Heat
Output
(kBtu/h)
Efficiency
Unit Efficiency
Total
Cooling
Output
(kBtu/h)
Efficiency
Unit Efficiency
RTUs (1-4)
Single Zone Heat
Pump (SZHP) Air
System
4 78.11 0 COP 3.4 76.81 EER 12 Fixed DB N
1 Status: N - New, A - Altered, E - Existing
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 11 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
H3. NONRESIDENTIAL / COMMON USE AREA FAN SYSTEMS SUMMARY
01 02 03 04 05 06 07 08 09 10 11 12 13
Name or Item Tag Qty Design OA
CFM
Supply Fan Return / Relief Fan
Status1
CFM Power Power Units Control Fan Type CFM Power Power Units Control
RTUs (1-4)4 475.06 2,600 1.69 BHP Constant Vol N/A N/A N/A N/A N/A N
1 Status: N - New, A - Altered, E - Existing
H8. SYSTEM SPECIAL FEATURES
01 02 03 04
System Name Equipment Type Interlocks per 140.4(n)1 Other Special Features and Controls
RTUs (1-4)Single Zone Heat Pump (SZHP) Air System N/A Fixed DB
DHW1 - SHW Service Hot Water N/A Fixed Temperature Control
Notes: This table includes controls related to the performance path only. For projects using the prescriptive path, mandatory and prescriptive controls requirements are documented on the
NRCC-MCH-E.
1 Yes = interlocks are provided, No = interlocks are not provided, NA means no operable openings.
H9. NONRESIDENTIAL / COMMON USE AREA & HOTEL/MOTEL VENTILATION
01 02 03 04 05 06 07
Zone Name Mechanical Ventilation Conditioned Area (sf)DCV or Occupant Sensor
Controls, or BothVentilation Function # of People Supply OA CFM Exhaust CFM
1-Zone 1 Retail - Sales 63.35 1900.25 0 7601 N/A
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 12 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
H11. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY
01 02 03 04 05 06 07 08 09 10 11 12
System ID System Type Qty
Rated Capacity (kBtuh)Airflow (cfm)Fan
VSD
Heating Cooling Design MIn.Min. Ratio Power Power
Units Cycles
1-Zone 1-Trm Uncontrolled 4 N/A N/A 10,400 N/A 0 N/A N/A N/A
PropNoClg-NonResZnSys Single Zone Air Conditioner 4 0 98.77 3,221.59 N/A N/A 0 W/cfm Cycling
I1. WATER HEATER EQUIPMENT SUMMARY
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Heater Element
Type Tank Type Qty
Tank
Vol
(gal)
Rated
Input
Rated
Input
Unit
Efficiency Efficiency
Unit
Tank
Insulation
R-value
Int/Ext
Standby
Loss
Fraction
1st Hr.
Rating or
Flow Rate
(gal)
Heat
Pump
Type
Tank Location or
Ambient
Condition
CHRONOMITE
SR-20L/1202 Electricity Instantaneous 1 1 2.4 kW 0.98 UEF N/A N/A 8 N/A N/A
L. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION
Selections made by Documentation Author indicate which Certificates of Installation must be submitted for the features to be recognized for compliance. These documents must be retained
and provided to the building inspector during construction and can be found online
Building Component Form/Title
Envelope NRCI-ENV-01-E - Must be submitted for all buildings
Envelope NRCI-ENV-E - Envelope (for all buildings)
Mechanical NRCI-MCH-01-E - Must be submitted for all buildings
Mechanical NRCI-MCH-E - For all buildings with Mechanical Systems
Plumbing NRCI-PLB-01-E - Must be submitted for all buildings
Plumbing NRCI-PLB-E - For all buildings with Plumbing Systems
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 13 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
M. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
Selections made by Documentation Author indicate which Certificates of Acceptance must be submitted for the features to be recognized for compliance. These documents must be provided
to the building inspector during construction and must be completed through an Acceptance Test Technician Certification Provider (ATTCP).
Building Component Form/Title & System Name(s)
Envelope NRCA-ENV-02-F - NRFC label verification for fenestration
Mechanical
NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note: MCH-02-A can be performed in conjunction with
MCH-07-A Supply Fan VFD Acceptance (if applicable) since testing activities overlap
RTUs (1-4)
Mechanical NRCA-MCH-03-A - Constant Volume Single Zone HVAC
RTUs (1-4)
Mechanical NRCA-MCH-05-A - Air Economizer Controls
RTUs (1-4)
Mechanical NRCA-MCH-12-A FDD for Packaged Direct Expansion Units
RTUs (1-4)
N. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION
Selections made by Documentation Author indicate which Certificates of Verification must be submitted for the features to be recognized for compliance. These documents must be retained
and provided to the building inspector during construction and can be found online
There are no Certificates of Verification applicable to this project
CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E
Nonresidential Performance Compliance Method (Page 14 of 14)
CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000
Schema Version: rev 20220601
Report Generated: 2024-11-05 02:29:44
Compliance ID: EnergyPro-6073-1124-0936
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Ray Parsi Documentation Author Signature:
Signature Date:Company: Pro Engineering
Address: 2712 Loker Avenue West #1063 CEA/HERS Certification Identification (if applicable): 26481
City/State/Zip: Carlsbad, CA 92010 Phone: (949)-842-2199
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of
Compliance (responsible designer)
3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this
Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable
compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5.I understand that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to
the enforcement agency for all applicable inspections, and I will take the necessary steps to accomplish this requirement.
6.I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to accomplish these requirements.
Responsible Designer Name: Jag Responsible Designer Signature:
Company: JAG Architecture
Address: 15 Hubble # 200 Date Signed:
City/State/Zip: Irvine, CA 92618 License #:
Phone: 949-752-9333 Title:Scope:
Responsible Designer Name: Ray Parsi Responsible Designer Signature:
Company: Pro Engineering Consulting Inc.
Address: 2712 Loker Avenue West #1063 Date Signed:
City/State/Zip: Carlsbad, CA 92010 License #: 26481
Phone: (949)-842-2199 Title:Scope:
2024/11/05
2024/11/05