BCOM2024-0157 - Energy ReportBUILDING ENERGY ANALYSIS REPORT PROJECT: Project Designer: Report Prepared by: Job Number: Date: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2022 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC – www.energysoft.com. DAISO 2712 Loker Avenue West #1063 15 Hubble # 200 Irvine, CA 92618 JAG Architecture Pro Engineering Ray Parsi 949-752-9333 La Quinta, CA 92253 11/5/2024 24490 Carlsbad, CA 92010 (949)-842-2199 78870 CA-111 12/10/2024 BCOM2024-0157 SHELL IMPROVEMENT IN ANTICIPATION OF NEW TENANT [VB/M-OCC/124-OL/SPRINK LED] THIS PERMIT DOES NOT INCLUDE T-BAR CEILING OR INSTALLATION OF GENERAL LIGHTING. 2022 CALIFORNIA BUILDING CODES. TABLE OF CONTENTS 3 1 Table of Contents 2 Form NRCC/LMCC-PRF-E Certificate of Compliance Cover Page CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 1 of 14) Project Name: Nonresidential Building Date Prepared: 2024-11-05 A. General Information 1 Project Name Nonresidential Building 2 Run Title Title 24 Analysis 3 Project Location 78870 CA-111 4 City La Quinta 5 Standards Version Compliance 2022 6 Zip code 92253 7 Compliance Software (version)EnergyPro 9.3 8 Climate Zone 15 9 Building Orientation (deg)135 10 Building Type(s)• Nonresidential 11 Weather File PALM-SPRINGS_STYP20.epw 12 Project Scope • Existing alteration 13 Number of Dwelling Units 0 14 Total Conditioned Floor Area in Scope (ft2)7601 15 Total # of hotel/motel rooms 0 16 Total Unconditioned Floor Area (ft2)0 17 Fuel Type Natural gas 18 Nonresidential Conditioned Floor Area 7601 19 Total # of Stories (Habitable Above Grade)1 20 Residential Conditioned Floor Area 0 CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 2 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 B. PROJECT SUMMARY Table B shows which building components are included in the performance calculation. If indicated as not included, the project must show compliance prescriptively if within the permit application. Building Components Complying via Performance Building Components Complying Prescriptively Envelope (See Table G) Nonres Performance Solar Thermal Water Heating (See Table I3) Performance The following building components are ONLY eligible for prescriptive compliance and should be documented on the NRCC form listed if within the scope of the permit application (i.e. compliance will not be shown on the NRCC-PRF-E).MultiFam Not Included Not Included Mechanical (See Table H) Nonres Performance Covered Process: Commercial Kitchens (see Table J) Performance Indoor Lighting (Unconditioned) 140.6 & 170.2(e) NRCC-LTI-E is required MultiFam Not Included Not Included Outdoor Lighting 140.7 & 170.2(e)NRCC-LTO-E is required Domestic Hot Water (See Table I) Nonres Performance Covered Process: Laboratory Exhaust (see Table J) Performance Sign Lighting 140.8 & 170.2(e)NRCC-LTS-E is required MultiFam Not Included Not Included Building Components Complying with Mandatory Measures Lighting (Indoor Conditioned, see Table K) Nonres Not Included Photovoltaics (see Table F) Performance Electrical power systems, commissioning, solar ready, elevator and escalator requirements are mandatory and should be documented on the NRCC form listed if applicable (i.e. compliance will not be shown on the NRCC-PRF-E.) MultiFam Not Included Not Included Electrical Power Distribution 110.11 NRCC-ELC-E is required Battery (see Table F) Performance Commissioning 120.8 NRCC-CXR-E is required Not Included Solar and Battery 110.10 NRCC-SAB-E is required CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 3 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 C1. COMPLIANCE SUMMARY COMPLIES3 Time Dependent Valuaton (TDV)Source Energy Use Efficiency1 (kBtu/ft2 - yr)Total2 (kBtu/ft2 - yr)Total2 (kBtu/ft2 - yr) Standard Design 519.18 n/a n/a Proposed Design 471.67 n/a n/a Compliance Margins 47.51 n/a n/a Pass n/a n/a 1 Efficiency measures include improvements like a better building envelope and more efficient equipment 2 Compliance Totals include efficiency, photovoltaics and batteries 3 New Construction, Complete Addition Scope: Building complies when all efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded Existing, Addition and Alteration Scope: Building complies when efficiency compliance margin is greater than or equal to zero and unmet load hour limits are not exceeded CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 4 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 C2. TDV ENERGY COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft 2 - yr) COMPLIES2 Energy Component Standard Design (TDV)Proposed Design (TDV)Compliance Margin (TDV)1 Space Heating 9.93 4.08 5.85 Space Cooling 277.83 256.89 20.94 Indoor Fans 130.77 110.33 20.44 Heat Rejection 0 0 0 Pumps & Misc.0 0 0 Domestic Hot Water 15.35 15.07 0.28 Indoor Lighting 85.3 85.3 0 Flexibility --------- EFFICIENCY COMPLIANCE TOTAL 519.18 471.67 47.51 (9.2%) Photovoltaics --------- Batteries --------- TOTAL COMPLIANCE 519.18 471.67 47.51 (9.2%) 1 Notes: This number in parenthesis following the Compliance Margin in column 4, represents the Percent Better than Standard. CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 5 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 C3. TDV ENERGY RESULTS FOR NON-REGULATED COMPONENTS1 Non-Regulated Energy Component Standard Design (TDV)Proposed Design (TDV)Compliance Margin (TDV)1 Receptacle 94.36 94.36 --- Process --------- Other Ltg --------- Process Motors --------- TOTAL (TOTAL COMPLIANCE + NON-REGULATED COMPONENTS)613.54 566.03 47.51 (7.7%) 1 Notes: This table is not used for Energy Code Compliance. C6. 'ABOVE CODE' QUALIFICATIONS This project is pursuing CalGreen Tier 1 This project is pursuing CalGreen Tier 2 CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 6 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 C7. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Space Heating ---0.9 ---26.2 ------ Space Cooling 59.6 54.7 4.9 --------- Indoor Fans 33.5 30.8 2.7 --------- Heat Rejection ------------------ Pumps & Misc.------------------ Domestic Hot Water 4.4 4.3 0.1 --------- Indoor Lighting 25 25 0 --------- Flexibility ------------------ EFFICIENCY TOTAL 122.5 115.7 6.8 26.2 0 26.2 Photovoltaics ------------------ Batteries ------------------ ENERGY USE SUBTOTAL 122.5 115.7 6.8 26.2 0 26.2 Receptacle 27.6 27.6 0 --------- Process ------------------ Other Ltg ------------------ Process Motors ------------------ ENERGY USE TOTAL 150.1 143.3 6.8 26.2 0 26.2 CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 7 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 C8. ENERGY USE INTENSITY (EUI) Standard Design (kBtu/ft2 / yr)Proposed Design (kBtu/ft2 / yr)Margin (kBtu/ft2 / yr)Margin Percentage GROSS EUI1 70.83 64.33 6.5 9.18 NET EUI1 70.83 64.33 6.5 9.18 1 Notes: Gross EUI is Energy Use Total (not including PV)/Total Building Area. Net EUI is Energy Use Total (including PV)/Total Building Area. D1. EXCEPTIONAL CONDITIONS • The project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary Daylit Control requirements are met. PRESCRIPTIVE COMPLIANCE documentation (form NRCC-LTI-02-E) for the requirements of section 140.6(d) Automatic Daylighting Controls in Secondary Daylit Zones is required. • The proposed building includes HVAC components that do not meet the mandatory efficiency requirements. • The user model includes space(s) that are designed to be served by mechanical cooling systems, but the cooling systems were not included in the simulation model. A cooling system has been modeled for both the proposed and standard cases. • The user model includes space(s) without sufficient cooling equipment. Cooling equipment has been added to the model to meet cooling loads. G1. ENVELOPE GENERAL INFORMATION (conditioned spaces only) 01 02 03 04 Opaque Surfaces & Orientation Total Gross Surface Area (ft2)Total Fenestration Area (ft2)Window to Wall Ratio (%) North-Facing1 585 0 0 East-Facing2 1275 1033 81.02 South-Facing3 1454 0 0 West-Facing4 990 0 0 Notes 1North-Facing is oriented to within 45 degrees of true north, including 45 00'00" east of north (NE), but excluding 45 00'00" west of north (NW), 2East-Facing is oriented to within 45 degrees of true east, including 45 00'00" south of east (SE), but excluding 45 00'00" north of east (NE), 3South-Facing is oriented to within 45 degrees of true south, including 45 00'00" west of south (SW), but excluding 45 00'00" east of south (SE), 4West-Facing is oriented to within 45 degrees of true west, including 45 00'00" north of west (NW), but excluding 45 00'00" south of west (SW), CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 8 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 G1. ENVELOPE GENERAL INFORMATION (conditioned spaces only) 01 02 03 04 Opaque Surfaces & Orientation Total Gross Surface Area (ft2)Total Fenestration Area (ft2)Window to Wall Ratio (%) Total 4304 1033 24 Roof 7601 0 0 Notes 1North-Facing is oriented to within 45 degrees of true north, including 45 00'00" east of north (NE), but excluding 45 00'00" west of north (NW), 2East-Facing is oriented to within 45 degrees of true east, including 45 00'00" south of east (SE), but excluding 45 00'00" north of east (NE), 3South-Facing is oriented to within 45 degrees of true south, including 45 00'00" west of south (SW), but excluding 45 00'00" east of south (SE), 4West-Facing is oriented to within 45 degrees of true west, including 45 00'00" north of west (NW), but excluding 45 00'00" south of west (SW), G4. NONRESIDENTIAL AIR BARRIER 01 02 Building Story Name Air Barrier Com-Floor 1 No air barrier CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 9 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 G5. OPAQUE SURFACE ASSEMBLY SUMMARY 01 02 03 04 05 06 07 08 09 10 Surface Name Construction Type Area (ft2)Framing Type Cavity R-Value Continuous R-Value Units Value Description of Assembly Layers Status1 Interior Exterior (ALT) 8 CMU Wall8 Exterior Wall 1,275 N/A 0 N/A N/A U-factor 0.3794 Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.A 8 CMU Wall12 Exterior Wall 3,029 N/A 0 N/A N/A U-factor 0.3794 Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.E 8 CMU Wall121 Interior Wall 924 N/A 0 N/A N/A U-factor 0.3179 Concrete - Part Grouted and Empty - 125 lb/ft3 - 8 in.E Slab On Grade19 Underground Floor 7,601 N/A 0 N/A N/A F-factor 0.73 Slab Type =Unheated slab on grade Insulation Orientation =None Insulation R-Value =none E (E) 4 CONCRETE ROOF21 Roof 7,601 Wood 0 N/A N/A U-factor 0.4806 Built-up roofing - 3/8 in. Plywood - 1/2 in. Composite-1 Concrete - 140 lb/ft3 - 4 in. E 1 Status: N - New, A - Altered, E - Existing G6A. OPAQUE DOOR SUMMARY (NONRESIDENTIAL) 01 02 03 04 Assembly Name Area (ft2)Overall U-factor Status1 Insulated Door15 21 0.2 E 1 Status: N - New, A - Altered, E - Existing CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 10 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 G7A. FENESTRATION ASSEMBLY SUMMARY (NONRESIDENTIAL) 01 02 03 04 05 06 07 08 09 Fenestration Assembly Name Fenestration Type/ Product Type / Frame Type Certification Method1 Assembly Method Area (ft2) Overall U-factor Overall SHGC Overall VT Status2 (E) Cooling Vertical fenestration Fixed window N/A NFRC Manufactured 899 0.3 0.23 0.5 E Cooling Vertical fenestration Fixed window N/A NFRC Manufactured 134 0.3 0.23 0.5 N 1 Notes: Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.6-A and Table 110.6-B. Center of Glass (COG) values are for the glass-only, determined by the manufacturer, and are shown for ease of verification. Site-built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. 2 Status: N - New, A - Altered, E - Existing H1. DRY SYSTEM EQUIPMENT (FURNACES, AIR HANDLING UNITS, HEAT PUMPS, VRF, ECONOMIZERS ETC.) 01 02 03 04 05 06 07 08 09 10 11 12 Equipment Name Equipment Type Qty Heating Cooling Economizer Type (if present) Status1Total Heating Output (kBtu/h) Supp Heat Output (kBtu/h) Efficiency Unit Efficiency Total Cooling Output (kBtu/h) Efficiency Unit Efficiency RTUs (1-4) Single Zone Heat Pump (SZHP) Air System 4 78.11 0 COP 3.4 76.81 EER 12 Fixed DB N 1 Status: N - New, A - Altered, E - Existing CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 11 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 H3. NONRESIDENTIAL / COMMON USE AREA FAN SYSTEMS SUMMARY 01 02 03 04 05 06 07 08 09 10 11 12 13 Name or Item Tag Qty Design OA CFM Supply Fan Return / Relief Fan Status1 CFM Power Power Units Control Fan Type CFM Power Power Units Control RTUs (1-4)4 475.06 2,600 1.69 BHP Constant Vol N/A N/A N/A N/A N/A N 1 Status: N - New, A - Altered, E - Existing H8. SYSTEM SPECIAL FEATURES 01 02 03 04 System Name Equipment Type Interlocks per 140.4(n)1 Other Special Features and Controls RTUs (1-4)Single Zone Heat Pump (SZHP) Air System N/A Fixed DB DHW1 - SHW Service Hot Water N/A Fixed Temperature Control Notes: This table includes controls related to the performance path only. For projects using the prescriptive path, mandatory and prescriptive controls requirements are documented on the NRCC-MCH-E. 1 Yes = interlocks are provided, No = interlocks are not provided, NA means no operable openings. H9. NONRESIDENTIAL / COMMON USE AREA & HOTEL/MOTEL VENTILATION 01 02 03 04 05 06 07 Zone Name Mechanical Ventilation Conditioned Area (sf)DCV or Occupant Sensor Controls, or BothVentilation Function # of People Supply OA CFM Exhaust CFM 1-Zone 1 Retail - Sales 63.35 1900.25 0 7601 N/A CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 12 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 H11. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY 01 02 03 04 05 06 07 08 09 10 11 12 System ID System Type Qty Rated Capacity (kBtuh)Airflow (cfm)Fan VSD Heating Cooling Design MIn.Min. Ratio Power Power Units Cycles 1-Zone 1-Trm Uncontrolled 4 N/A N/A 10,400 N/A 0 N/A N/A N/A PropNoClg-NonResZnSys Single Zone Air Conditioner 4 0 98.77 3,221.59 N/A N/A 0 W/cfm Cycling I1. WATER HEATER EQUIPMENT SUMMARY 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Heater Element Type Tank Type Qty Tank Vol (gal) Rated Input Rated Input Unit Efficiency Efficiency Unit Tank Insulation R-value Int/Ext Standby Loss Fraction 1st Hr. Rating or Flow Rate (gal) Heat Pump Type Tank Location or Ambient Condition CHRONOMITE SR-20L/1202 Electricity Instantaneous 1 1 2.4 kW 0.98 UEF N/A N/A 8 N/A N/A L. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections made by Documentation Author indicate which Certificates of Installation must be submitted for the features to be recognized for compliance. These documents must be retained and provided to the building inspector during construction and can be found online Building Component Form/Title Envelope NRCI-ENV-01-E - Must be submitted for all buildings Envelope NRCI-ENV-E - Envelope (for all buildings) Mechanical NRCI-MCH-01-E - Must be submitted for all buildings Mechanical NRCI-MCH-E - For all buildings with Mechanical Systems Plumbing NRCI-PLB-01-E - Must be submitted for all buildings Plumbing NRCI-PLB-E - For all buildings with Plumbing Systems CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 13 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 M. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections made by Documentation Author indicate which Certificates of Acceptance must be submitted for the features to be recognized for compliance. These documents must be provided to the building inspector during construction and must be completed through an Acceptance Test Technician Certification Provider (ATTCP). Building Component Form/Title & System Name(s) Envelope NRCA-ENV-02-F - NRFC label verification for fenestration Mechanical NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note: MCH-02-A can be performed in conjunction with MCH-07-A Supply Fan VFD Acceptance (if applicable) since testing activities overlap RTUs (1-4) Mechanical NRCA-MCH-03-A - Constant Volume Single Zone HVAC RTUs (1-4) Mechanical NRCA-MCH-05-A - Air Economizer Controls RTUs (1-4) Mechanical NRCA-MCH-12-A FDD for Packaged Direct Expansion Units RTUs (1-4) N. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION Selections made by Documentation Author indicate which Certificates of Verification must be submitted for the features to be recognized for compliance. These documents must be retained and provided to the building inspector during construction and can be found online There are no Certificates of Verification applicable to this project CERTIFICATE OF COMPLIANCE - NONRESIDENTIAL PERFORMANCE COMPLIANCE METHOD NRCC-PRF-E Nonresidential Performance Compliance Method (Page 14 of 14) CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220601 Report Generated: 2024-11-05 02:29:44 Compliance ID: EnergyPro-6073-1124-0936 Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ray Parsi Documentation Author Signature: Signature Date:Company: Pro Engineering Address: 2712 Loker Avenue West #1063 CEA/HERS Certification Identification (if applicable): 26481 City/State/Zip: Carlsbad, CA 92010 Phone: (949)-842-2199 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Compliance is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3.The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5.I understand that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections, and I will take the necessary steps to accomplish this requirement. 6.I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy, and I will take the necessary steps to accomplish these requirements. Responsible Designer Name: Jag Responsible Designer Signature: Company: JAG Architecture Address: 15 Hubble # 200 Date Signed: City/State/Zip: Irvine, CA 92618 License #: Phone: 949-752-9333 Title:Scope: Responsible Designer Name: Ray Parsi Responsible Designer Signature: Company: Pro Engineering Consulting Inc. Address: 2712 Loker Avenue West #1063 Date Signed: City/State/Zip: Carlsbad, CA 92010 License #: 26481 Phone: (949)-842-2199 Title:Scope:   2024/11/05 2024/11/05