Loading...
BSOL2021-0069BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 06/07/2021 ISSUED DATE: 07/06/2021 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 45455 DEERBROOK CIR BSOL2021-0069 604405011 $22,070.00 Owner:Lee Melville 45455 Deerbrook Circle, La Quinta, CA 94804 Applicant:SunPower Corporation Systems 1414 HARBOUR WAY SOUTH #1901, RICHMOND, CA 94804 Contractor:SunPower Corporation Systems / 890895 1414 HARBOUR WAY SOUTH #1901, RICHMOND, CA 94804 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 5/23/25 9:08 am Page 1 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2021-0069 45455 DEERBROOK CIR BUILDING PERMIT application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 5/23/25 9:08 am Page 2 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2021-0069 45455 DEERBROOK CIR BUILDING PERMIT MELVILLE/ 11.07kW PV SYSTEM - (27) 410W AC PANELS + 100A SUB *** 11.48kW SOLAR ARRAY - (27) SUNPOWER SPR-A410-G-AC PANELS W/INTEGRATED SPWR-A4 MICROINVERTERS + NEW 100A LOAD CENTER + RELOCATE EXISTING LOADS TO NEW SUBPANEL [486SF] 2019 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 4PV Strings (EA)1PV Miscellaneous Equipment EA Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BSOL2021-006 9 $26.83 PV SYSTEM MISC EQUIPMENT PC $26.83 $40.25 PV SYSTEM GREATER THAN 10KW PC $40.25 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $10.00 RECORDS MANAGEMENT FEE $10.00 $1.00 BSAS SB1473 FEE $1.00 $101.97 PERMIT ISSUANCE $101.97 $26.83 PV SYSTEM MISC EQUIPMENT $26.83 $40.25 PV SYSTEM GREATER THAN 10KW $40.25 $252.13 $252.13 Total for Invoice PERMIT-BSOL2021-0069 Grand Total for Permit $252.13 $252.13 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 06/07/2021 0:00 FINAL** v.1 Inspection Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections Printed: 5/23/25 9:08 am Page 3 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2021-0069 45455 DEERBROOK CIR BUILDING PERMIT A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 5/23/25 9:08 am Page 4 of 4 CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA FIRE CODE (CFC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA PLUMBING CODE (CPC) A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA GRID TIED PHOTOVOLTAIC SYSTEM SOLAR INDIVIDUAL PERMIT PACKAGE LEE MELVILLE 45455 DEERBROOK CIRCLE (714) 404-9399 LA QUINTA, CALIFORNIA 92253 11.07 kW AHJ: LA QUINTA UTILITY: IMPERIAL IRRIGATION DISTRICT SATELLITE IMAGE JOB NOTES CO V E R S H E E T PROJECT LOCATION NTS PV SOLAR ARCHITECTURAL DRAWINGS SHEET INDEX PV SOLAR ELECTRICAL DRAWINGS PVE-1 ELECTRICAL SINGLE-LINE DIAGRAM & PVE-2 ELECTRICAL CALCULATION PVE-3 ELECTRICAL DATA & SPECIFICATIONS SPECIFICATIONS PVE-4 PVE-5 BRANCH DIAGRAM PV SOLAR STRUCTURAL DRAWINGS PVS-1 MOUNTING DETAILS PVA-0 COVER SHEET PVA-1 ARRAY LAYOUT EQUINOX GROUNDING DETAILS PVA-0 ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. BSOL2021-0069 11.48kW SOLAR ARRAY - (27) SUNPOWER SPR-A410-G-AC PANELS W/INTEGRATED SPWR-A4 MICROINVERTERS + NEW 100A LOAD CENTER + RELOCATE EXISTING LOADS TO NEW SUBPANEL [486SF] 2019 CALIFORNIA BUILDING CODES. 07/06/2021 DEERB R O O K C I R C L E R O O F 1 ROOF 2 2 9 ' - 3 " 6 8 ' - 7 " 2 9 ' - 8 " 11'-3" 52'-9" 10'-6" N - L C M (E) POOL (E) GARAGE 3' ROOF ACCESS POINT 3' ROOF ACCESS POINT 18" FIRE SETBACK (TYP.) (E) GATE LOCKABLE, LABELED, PV SYSTEM DISCONNECT N A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA AR R A Y L A Y O U T ROOF TYPE CONTRACT MODULE MICROINVERTER STORY & QUANTITY TYPE & QUANTITY HOME TYPE TOTAL ARRAY AREA ROOF ATTACHMENT QUANTITY SQ.FT. WAVED TILE 1 - STORY 27 SPR-A410-G-AC (240) 27 IQ7AS-66-ACM-US (240) 58 552 1/16" = 1'-0" L E G E N D JUNCTION BOX SERVICE POINT AND UTILITY METERING PROPERTY LINE FIRE ACCESS PATH CONDUIT N-LC NEW LOAD CENTER NOTE: 1.FIELD ADJUSTMENTS OF FEWER THAN 6” MAY BE ALLOWED BASED ON SITE CONDITIONS AND MEASUREMENTS. N 1 2ROOF AZIMUTH PITCH MODULE QTY. 3:12 339° 19 3:12 249° 8 PVA-1 07/06/2021 FIGURE 3: MOUNTING CLAMP POSITIONING DETAILS ·RAILS SHALL BE POSITIONED IN THE NON-CROSS HATCHED REGIONS 66 CELL MODULE 2"11.8"2"11.8" 11 " 17 " 2" 26 " MI C R O I N V E R T E R E X C L U S I O N Z O N E TABLE 2: PENETRATION GUIDE FOR INSTALL STACKED STAGGERED FULLY STAGGERED STACKED/STAGGEREDFULLY STAGGERED *CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY. TWO OR MORE ROWS OF MODULES ONE ROW OF MODULES TABLE 1 – ARRAYS INFORMATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE NO. OF STORIES FRAMING TYPE (in.) MAX. RAFTER SPAN (ft.) PENETRATION PATTERN (in.) MAX. ATTACHMENT SPACING (in.) MAX. RAIL OVERHANG (in.) ROOF 1 15°W-Tile Pegasus Tile Gen 2 2 2x4 Truss @ 24" OC 6'Stacked 48"16" ROOF 2 15°W-Tile Pegasus Tile Gen 2 2 2x4 Truss @ 24" OC 6'Stacked 48"16" ROOF 3 ------------------ ROOF 4 ------------------ ROOF 5 ------------------ ROOF 6 ------------------ CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE FIGURE 2: INVISIMOUNT WITH PEGASUS SOLAR ROOF ATTACHMENT DETAILS @ TRUSS / RAFTERS 0.75" MIN. 2- 1 / 2 " M I N . (2) 5/16" LG. S.S. LAG BOLT WITH 5/16" WASHER @ CENTER TYP. PRE-DRILL REQUIRED. 1. 8 " L FOOT INVISIMOUNT RAIL PV MODULEPV MODULE (E) WOOD SHEATHING BASE FLASHING SLED TILE POST ASSEMBLY 1" ELEVATED CONE WITH EPDM BOOT FIG 1.1: ROOF 1 STRUCTURAL FRAMING DETAIL FIG 1.2: ROOF 2 STRUCTURAL FRAMING DETAIL PV MODULE BASE FLASHING L FOOT EXTERNAL LOAD BEARING WALL PV MODULE BASE FLASHING L FOOT EXTERNAL LOAD BEARING WALL A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA ST R U C T U R A L I N F O R M A T I O N AN D M O U N T I N G D E T A I L S NTS PVS-1 07/06/2021 C NO 3THWN-2 EGC: THWN-2 1 C #4 #8 EMT 1" AC MODULES NOTES 1.DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENT OF NEC 690.35. 2.SUNPOWER PROVIDED CABLES COMES WITH TWO (2) #12 AWG WIRE AND THIS IS BY DESIGN. NEUTRAL AND ADDITIONAL GROUND WIRE IS NOT REQUIRED FOR PROVIDED TRUNK AND EXTENSION CABLES. 3.SUNPOWER AC MODULES HAVE BEEN TESTED AND CERTIFIED TO UL 2703 FOR INTEGRATED GROUNDING AND HENCE A SEPARATE GROUND WIRE IS NOT REQUIRED WITHIN THE ARRAY. 4.USE ROW-TO-ROW GROUNDING CLIP PROVIDED TO GROUND ROWS OF MODULE. BOND SUB-ARRAYS BY RUNNING #6 AWG BARE CU WIRE AND GROUND LUGS AT A SINGLE POINT ON EACH SUB-ARRAY AND THEN TO THE JUNCTION BOX. REFER TO PVE-4 FOR ADDITIONAL DETAILS. EGC: BARE Cu #6 BRANCH CIRCUIT FROM PV ARRAY TO JUNCTION BOX ELECTRICAL NOTES 1.PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 2.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. 3.MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED. 4.EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. 5.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 6.TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS. 7.IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY. 8.AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 9.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 10.EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE. 11.AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY #12 2 A -- CHECK BOX FOR WHETHER SYSTEM IS GROUNDED OR UNGROUNDED: GROUNDED (INCLUDE GEC) UNGROUNDED FOR UNGROUNDED SYSTEMS: · DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH SOURCE CIRCUIT. · UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER 210.5(C). WHITE FINISHED CONDUCTORS ARE NOT PERMITTED. ü TAG 1 2 3 4 5 6 7 8 9 DC / DC CONVERTERS SOURCE CIRCUIT JUNCTION BOX SEPARATE DC DISCONNECT INTERNAL INVERTER DC DISCONNECT STRING INVERTER SOLAR LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION 1 SOLAR AC MODULE / BRANCH EXISTING GROUND HMCB INCOMING SOURCE FEED , 120/240 V, 1 PH, 3 W TO EXISTING LOADS PV BREAKER: TO BE INSTALLED ON THE OPPOSITE SIDE OF THE MAIN OCPD OF THE BUSBAR CENTER FED *MSP MAX PV BREAKER (A): x 120% - = LOCATION: MANUF: (E) UTILITY BIDIRECTIONAL METER #: NOTE: "PER NEC 705.12(B)(2)(3)(d), A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANELBOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING OF THE BUSBAR. 50A 125A 50A, 2P SOUTH-WEST CUTLLER HAMMER IID-1B4B-232166 (E) 100A, 2P 125A 100A (E) MAIN SERVICE PANEL B JUNCTION BOX, NEMA-3R 3 THWN-2 EGC: THWN-2 1 6 B #10 #10 EMT 3/4" #10 #10 #10 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE (AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF CONDUCTORS (N) SOLAR LOAD CENTER MIN., 120/240 V, M.L.O, NEMA-3R MLO YES 7 LOCATION: 20A, 2P 20A, 2P 20A, 2P SOUTH-WEST 100A MICROINVERTER MODEL: IQ7AS-66-ACM-US (240) NO 15A, 2P ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e PVS6 (3) #14 THWN (1) #14 THWN EGC RELOCATED (E) LOADS FROM MSP TO THIS LOAD CENTER PV BREAKER = MODULES x x 1.25 = RELOCATED BREAKER(S) = LOAD CENTER FEEDER BREAKER = NOTE: AFCI BREAKERS REQUIRED IF CIRCUITS RELOCATED MORE THAN 6 FT. 1.45A 50A, 2P 15A 1P, 15A 1P, 15A 1P, 15A 1P 27 50A, 2P NO NO YES ACM NO NO 1 ROOFTOP ARRAY WIRING A DC AC DC AC DC AC 1 SUNPOWER MODULES Branch Circuit #1 Branch Circuit #2 Branch Circuit #3 SPR-A410-G-AC (240) 10 AC MODULES 9 AC MODULES 8 AC MODULES TAG PV SYSTEM DISCONNECT A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA NTS FIGURE A: SINGLE LINE DIAGRAM - 11.07 kW EL E C T R I C A L S I N G L E - L I N E D I A G R A M & S P E C I F I C A T I O N S PVE-1 07/06/2021 ELECTRICAL CALCULATIONS BRANCH 2 BRANCH 3BRANCH 1 NUMBER OF MODULES VOLTAGE RATED AC OUTPUT CURRENT: IOUT = MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE TEMPERATURE ADDER TEMPERATURE USED FOR AMPACITY DE-RATING TEMPERATURE DE-RATING COEFFICIENT FILL DE-RATING COEFFICIENT IWIREMIN = IMAX / TEMP_COEFF / FILL_COEFF WIRE SIZE AMPACITY CONDUCTOR SIZE CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP OVERCURRENT PROTECTION MINIMUM OCPD = IOUT x 1.25 CALCULATED VOLTAGE DROP ONE WAY CIRCUIT LENGTH SUBPANEL TO GRID-TIE WIRING VOLTAGE SUM OF BRANCHES: IOUT_TOTAL = MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE TEMPERATURE USED FOR AMPACITY DE-RATING TEMPERATURE DE-RATING COEFFICIENT FILL DE-RATING COEFFICIENT IWIREMIN = IMAX / TEMP_COEFF / FILL_COEFF WIRE SIZE AMPACITY CONDUCTOR SIZE CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP OVERCURRENT PROTECTION MINIMUM OCPD = IOUT x 1.25 VOLTAGE DROP ONE WAY CIRCUIT LENGTH ROOF JCT BOX TO SUBPANEL WIRING #10 9 240 V 13.05 A 16.31 A 47 °C 22 °C 69 °C 0.58 0.8 35.16 A 40 A #10 #10 0.67% 20A, 2P 16.31 A #10 10 240 V 14.5 A 18.13 A 47 °C 22 °C 69 °C 0.58 0.8 39.06 A 40 A #10 #10 0.75% 20A, 2P 18.13 A #10 8 240 V 11.6 A 14.50 A 47 °C 22 °C 69 °C 0.58 0.8 31.25 A 40 A #10 #10 0.60% 20A, 2P 14.50 A 50 FT.50 FT.50 FT. 48.94 A 50A, 2P 0.08% #4 #4 85 A 65.25 A 1.00 0.75 47 °C 47 °C #4 5 FT. 48.94 A 39.15 A 240 V A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA EL E C T R I C A L C A L C U L A T I O N NTS PVE-2 07/06/2021 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3 8" LETTER HEIGHT, WHITE ON RED BACKGROUND. 3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. 4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY 10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER AND JUNCTION BOXES. 5.DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. SIGNAGE NOTES ELECTRICAL DATA & SPECIFICATIONS PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL ·INDOOR / OUTDOOR SUBPANEL MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL ·NEW INDOOR / OUTDOOR LOAD CENTER ·INDOOR / OUTDOOR SUBPANEL 39.15 A 240 V · RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SIGNAGE LOCATIONS: ·SHALL BE LOCATED ON OR NO MORE THAN 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA EL E C T R I C A L D A T A & S P E C I F I C A T I O N S NTS PVE-3 PV SYSTEM DISCONNECT SIGNAGE LOCATION: PV SYSTEM DISCONNECTING MEANS 07/06/2021 A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA N - L C M FIGURE 1: SUNPOWER EQUINOX GROUNDING DETAILS NTS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN: CAUTION: MAIN SERVICE PANEL PHOTOVOLTAIC ARRAY ON ROOF SOLAR LOAD CENTER FIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES UTILITY METER 45455 DEERBROOK CIRCLE PVE-4 07/06/2021 R O O F 1 ROOF 2 N - L C M A.Dsouza PROJECT INSTALLER 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: DATE DRAWN SCALE A ADDED NOTE ON PVA0 6/30/2021 AD MARKED PV BREAKER MAIN BREAKER EXISTING PVE1 LE E M E L V I L L E 45 4 5 5 D E E R B R O O K C I R C L E LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 RP-160389 11 . 0 7 k W SPRI - ONTARIO 06-05-2021 C A L I C E N S E # 8 9 0 8 9 5 ARUN DSOUZA BR A N C H D I A G R A M 3/32" = 1'-0" INSTALLER NAME: _____________________ BRANCH VOLTAGES: 1. 2. 3. 4. 5. 6. 1 2ROOF AZIMUTH PITCH MODULE QTY. 3:12 339° 19 3:12 249° 8 N PVE-5 FIGURE 1: PV MODULE SPECIFICATION SHEET FIGURE 2: PV MODULE SPECIFICATION SHEET SHEET 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . REV DESCRIPTION DATE DB CB R E V I S I O N S FI L E : S P _ S t a n d a r d _ W o r k i n g _ D r a w i n g _ S P D _ V 3 _ ( X r e f ' d ) ( 1 ) . d w g , U S E R : a l b l a n c o , D A T E / T I M E : J a n 1 5 , 2 0 2 0 - 1 2 : 3 8 a m C A L I C E N S E # 8 9 0 8 9 5 FIGURE 1: PEGASUS SOLAR MOUNTING DATA SHEET FIGURE 2: PEGASUS SOLAR MOUNTING DATA SHEET FI L E : P e g a s u s S o l a r _ S P E C S H E E T S . d w g , U S E R : r e u d e , D A T E / T I M E : M a r 2 0 , 2 0 1 7 - 7 : 4 3 p m SHEET REV DESCRIPTION DATE DB CB R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . SCALE DRAWN BY PROJECT DATE DRAWN OPPORTUNITY CHECKED BY DATE CHECKED NTS C A L I C E N S E # 8 9 0 8 9 5 FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR CERTIFICATION LETTER FI L E : S P D _ P S _ S P E C S H E E T S . d w g , U S E R : r e u d e , D A T E / T I M E : M a r 2 0 , 2 0 1 7 - 7 : 3 0 p m SHEET REV DESCRIPTION DATE DB CB R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . SCALE DRAWN BY PROJECT DATE DRAWN OPPORTUNITY CHECKED BY DATE CHECKED C A L I C E N S E # 8 9 0 8 9 5 NTS FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR TEST VERIFICATION OF CONFORMITY FI L E : P e g a s u s S o l a r _ S P E C S H E E T S . d w g , U S E R : r e u d e , D A T E / T I M E : M a r 2 0 , 2 0 1 7 - 7 : 4 4 p m SHEET REV DESCRIPTION DATE DB CB R E V I S I O N S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . SCALE DRAWN BY PROJECT DATE DRAWN OPPORTUNITY CHECKED BY DATE CHECKED C A L I C E N S E # 8 9 0 8 9 5 NTS FIGURE 2: INVISIMOUNT DATASHEETFIGURE 1: INVISIMOUNT DATA SHEET SHEET DRAWN BY DATE DRAWN DATE CHECKED SCALE CHECKED BY 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . R E V I S I O N S REV DESCRIPTION DATE DB CB C A L I C E N S E # 8 9 0 8 9 5 PROJECT OPPORTUNITY FIGURE 1: PVS6 SPECIFICATION SHEET FIGURE 1: PVS6 SPECIFICATION SHEET SHEET DRAWN BY DATE DRAWN DATE CHECKED SCALE CHECKED BY 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . R E V I S I O N S REV DESCRIPTION DATE DB CB C A L I C E N S E # 8 9 0 8 9 5 PROJECT OPPORTUNITY