BSOL2021-0069BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 06/07/2021
ISSUED DATE: 07/06/2021
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Solar
45455 DEERBROOK CIR
BSOL2021-0069
604405011
$22,070.00
Owner:Lee Melville
45455 Deerbrook Circle, La Quinta, CA 94804
Applicant:SunPower Corporation Systems
1414 HARBOUR WAY SOUTH #1901, RICHMOND,
CA 94804
Contractor:SunPower Corporation Systems / 890895
1414 HARBOUR WAY SOUTH #1901, RICHMOND,
CA 94804
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 5/23/25 9:08 am Page 1 of 4
Permit Type:
Permit Number:
Property Address:
Solar
BSOL2021-0069
45455 DEERBROOK CIR
BUILDING PERMIT
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
Printed: 5/23/25 9:08 am Page 2 of 4
Permit Type:
Permit Number:
Property Address:
Solar
BSOL2021-0069
45455 DEERBROOK CIR
BUILDING PERMIT
MELVILLE/ 11.07kW PV SYSTEM - (27) 410W AC PANELS + 100A SUB *** 11.48kW SOLAR ARRAY - (27) SUNPOWER SPR-A410-G-AC
PANELS W/INTEGRATED SPWR-A4 MICROINVERTERS + NEW 100A LOAD CENTER + RELOCATE EXISTING LOADS TO NEW
SUBPANEL [486SF] 2019 CALIFORNIA BUILDING CODES.
Use of Permit
Construction Details
4PV Strings (EA)1PV Miscellaneous
Equipment EA
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
PERMIT-BSOL2021-006
9
$26.83 PV SYSTEM MISC EQUIPMENT PC $26.83
$40.25 PV SYSTEM GREATER THAN 10KW PC $40.25
$5.00 TECHNOLOGY ENHANCEMENT FEE $5.00
$10.00 RECORDS MANAGEMENT FEE $10.00
$1.00 BSAS SB1473 FEE $1.00
$101.97 PERMIT ISSUANCE $101.97
$26.83 PV SYSTEM MISC EQUIPMENT $26.83
$40.25 PV SYSTEM GREATER THAN 10KW $40.25
$252.13 $252.13 Total for Invoice PERMIT-BSOL2021-0069
Grand Total for Permit $252.13 $252.13
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Inspections v.1 06/07/2021 0:00
FINAL** v.1 Inspection
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
Printed: 5/23/25 9:08 am Page 3 of 4
Permit Type:
Permit Number:
Property Address:
Solar
BSOL2021-0069
45455 DEERBROOK CIR
BUILDING PERMIT
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 5/23/25 9:08 am Page 4 of 4
CODE INFORMATION
APPLICABLE CODES, LAWS AND REGULATIONS
2019 CALIFORNIA BUILDING CODE (CBC)
2019 CALIFORNIA RESIDENTIAL CODE (CRC)
2019 CALIFORNIA FIRE CODE (CFC)
2019 CALIFORNIA ELECTRICAL CODE (CEC)
2019 CALIFORNIA MECHANICAL CODE (CMC)
2019 CALIFORNIA PLUMBING CODE (CPC)
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
GRID TIED PHOTOVOLTAIC SYSTEM
SOLAR INDIVIDUAL PERMIT PACKAGE
LEE MELVILLE
45455 DEERBROOK CIRCLE
(714) 404-9399
LA QUINTA, CALIFORNIA 92253
11.07 kW
AHJ: LA QUINTA
UTILITY: IMPERIAL IRRIGATION DISTRICT
SATELLITE IMAGE
JOB NOTES
CO
V
E
R
S
H
E
E
T
PROJECT LOCATION
NTS
PV SOLAR ARCHITECTURAL DRAWINGS
SHEET INDEX
PV SOLAR ELECTRICAL DRAWINGS
PVE-1 ELECTRICAL SINGLE-LINE DIAGRAM &
PVE-2 ELECTRICAL CALCULATION
PVE-3 ELECTRICAL DATA & SPECIFICATIONS
SPECIFICATIONS
PVE-4
PVE-5 BRANCH DIAGRAM
PV SOLAR STRUCTURAL DRAWINGS
PVS-1 MOUNTING DETAILS
PVA-0 COVER SHEET
PVA-1 ARRAY LAYOUT
EQUINOX GROUNDING DETAILS
PVA-0
ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE.
BSOL2021-0069
11.48kW SOLAR ARRAY - (27)
SUNPOWER SPR-A410-G-AC
PANELS W/INTEGRATED
SPWR-A4 MICROINVERTERS
+ NEW 100A LOAD CENTER +
RELOCATE EXISTING LOADS
TO NEW SUBPANEL [486SF]
2019 CALIFORNIA BUILDING
CODES.
07/06/2021
DEERB
R
O
O
K
C
I
R
C
L
E
R
O
O
F
1
ROOF
2
2
9
'
-
3
"
6
8
'
-
7
"
2
9
'
-
8
"
11'-3"
52'-9"
10'-6"
N
-
L
C
M
(E) POOL
(E) GARAGE
3' ROOF ACCESS
POINT
3' ROOF ACCESS
POINT
18" FIRE SETBACK (TYP.)
(E) GATE
LOCKABLE, LABELED, PV
SYSTEM DISCONNECT
N
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
AR
R
A
Y
L
A
Y
O
U
T
ROOF TYPE
CONTRACT MODULE
MICROINVERTER
STORY
& QUANTITY
TYPE & QUANTITY
HOME TYPE
TOTAL
ARRAY AREA
ROOF ATTACHMENT
QUANTITY
SQ.FT.
WAVED TILE
1 - STORY
27 SPR-A410-G-AC (240)
27 IQ7AS-66-ACM-US (240)
58
552
1/16" = 1'-0"
L E G E N D
JUNCTION BOX
SERVICE POINT AND
UTILITY METERING
PROPERTY LINE
FIRE ACCESS PATH
CONDUIT
N-LC NEW LOAD CENTER
NOTE:
1.FIELD ADJUSTMENTS OF FEWER
THAN 6” MAY BE ALLOWED BASED ON SITE
CONDITIONS AND MEASUREMENTS.
N
1 2ROOF
AZIMUTH
PITCH
MODULE
QTY.
3:12
339°
19
3:12
249°
8
PVA-1
07/06/2021
FIGURE 3: MOUNTING CLAMP
POSITIONING DETAILS
·RAILS SHALL BE POSITIONED IN THE NON-CROSS
HATCHED REGIONS
66 CELL MODULE
2"11.8"2"11.8"
11
"
17
"
2"
26
"
MI
C
R
O
I
N
V
E
R
T
E
R
E
X
C
L
U
S
I
O
N
Z
O
N
E
TABLE 2: PENETRATION GUIDE FOR INSTALL
STACKED STAGGERED FULLY STAGGERED
STACKED/STAGGEREDFULLY STAGGERED
*CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY.
TWO OR MORE ROWS OF MODULES
ONE ROW OF MODULES
TABLE 1 – ARRAYS INFORMATION
ROOF
PITCH
ROOFING
TYPE
ATTACHMENT
TYPE
NO. OF
STORIES
FRAMING
TYPE (in.)
MAX.
RAFTER
SPAN (ft.)
PENETRATION
PATTERN (in.)
MAX. ATTACHMENT
SPACING (in.)
MAX. RAIL
OVERHANG (in.)
ROOF 1 15°W-Tile Pegasus Tile Gen 2 2 2x4 Truss @ 24" OC 6'Stacked 48"16"
ROOF 2 15°W-Tile Pegasus Tile Gen 2 2 2x4 Truss @ 24" OC 6'Stacked 48"16"
ROOF 3 ------------------
ROOF 4 ------------------
ROOF 5 ------------------
ROOF 6 ------------------
CHECK TABLE 2 FOR PENETRATION PATTERN GUIDE
FIGURE 2: INVISIMOUNT WITH PEGASUS SOLAR ROOF ATTACHMENT DETAILS @ TRUSS / RAFTERS
0.75" MIN.
2-
1
/
2
"
M
I
N
.
(2) 5/16" LG. S.S. LAG BOLT WITH
5/16" WASHER @ CENTER TYP.
PRE-DRILL REQUIRED.
1.
8
"
L FOOT
INVISIMOUNT RAIL
PV MODULEPV MODULE
(E) WOOD SHEATHING
BASE FLASHING
SLED
TILE POST ASSEMBLY
1" ELEVATED CONE WITH
EPDM BOOT
FIG 1.1: ROOF 1 STRUCTURAL FRAMING DETAIL
FIG 1.2: ROOF 2 STRUCTURAL FRAMING DETAIL
PV MODULE
BASE FLASHING
L FOOT
EXTERNAL LOAD
BEARING WALL
PV MODULE
BASE FLASHING
L FOOT
EXTERNAL LOAD
BEARING WALL
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
ST
R
U
C
T
U
R
A
L
I
N
F
O
R
M
A
T
I
O
N
AN
D
M
O
U
N
T
I
N
G
D
E
T
A
I
L
S
NTS
PVS-1
07/06/2021
C
NO
3THWN-2
EGC: THWN-2 1
C
#4
#8
EMT 1"
AC MODULES NOTES
1.DC CIRCUIT IS ISOLATED AND INSULATED FROM GROUND AND MEETS THE REQUIREMENT OF NEC 690.35.
2.SUNPOWER PROVIDED CABLES COMES WITH TWO (2) #12 AWG WIRE AND THIS IS BY DESIGN. NEUTRAL AND ADDITIONAL GROUND WIRE
IS NOT REQUIRED FOR PROVIDED TRUNK AND EXTENSION CABLES.
3.SUNPOWER AC MODULES HAVE BEEN TESTED AND CERTIFIED TO UL 2703 FOR INTEGRATED GROUNDING AND HENCE A SEPARATE GROUND
WIRE IS NOT REQUIRED WITHIN THE ARRAY.
4.USE ROW-TO-ROW GROUNDING CLIP PROVIDED TO GROUND ROWS OF MODULE. BOND SUB-ARRAYS BY RUNNING #6 AWG BARE CU WIRE
AND GROUND LUGS AT A SINGLE POINT ON EACH SUB-ARRAY AND THEN TO THE JUNCTION BOX. REFER TO PVE-4 FOR ADDITIONAL
DETAILS.
EGC: BARE Cu #6
BRANCH CIRCUIT
FROM PV ARRAY TO
JUNCTION BOX
ELECTRICAL NOTES
1.PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC.
2.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS.
3.MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED.
4.EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS.
5.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
6.TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS.
7.IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY.
8.AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
9.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT.
10.EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE.
11.AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED.
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY #12 2
A --
CHECK BOX FOR WHETHER SYSTEM IS GROUNDED OR
UNGROUNDED:
GROUNDED (INCLUDE GEC)
UNGROUNDED
FOR UNGROUNDED SYSTEMS:
· DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH
SOURCE CIRCUIT.
· UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER
210.5(C). WHITE FINISHED CONDUCTORS ARE NOT
PERMITTED.
ü
TAG
1
2
3
4
5
6
7
8
9
DC / DC CONVERTERS
SOURCE CIRCUIT JUNCTION BOX
SEPARATE DC DISCONNECT
INTERNAL INVERTER DC DISCONNECT
STRING INVERTER
SOLAR LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
1
SOLAR AC MODULE / BRANCH
EXISTING
GROUND
HMCB
INCOMING SOURCE FEED
, 120/240 V, 1 PH, 3 W
TO
EXISTING
LOADS
PV BREAKER: TO BE
INSTALLED ON THE OPPOSITE SIDE
OF THE MAIN OCPD OF THE BUSBAR
CENTER FED
*MSP MAX PV BREAKER (A):
x 120% -
=
LOCATION:
MANUF:
(E) UTILITY
BIDIRECTIONAL
METER #:
NOTE:
"PER NEC 705.12(B)(2)(3)(d), A CONNECTION AT
EITHER END, BUT NOT BOTH ENDS, OF A
CENTER-FED PANELBOARD IN DWELLINGS
SHALL BE PERMITTED WHERE THE SUM OF 125
PERCENT OF THE POWER SOURCE(S) OUTPUT
CIRCUIT CURRENT AND THE RATING OF THE
OVERCURRENT DEVICE PROTECTING THE
BUSBAR DOES NOT EXCEED 120 PERCENT OF
THE CURRENT RATING OF THE BUSBAR.
50A
125A
50A, 2P
SOUTH-WEST
CUTLLER HAMMER
IID-1B4B-232166
(E) 100A, 2P
125A 100A
(E) MAIN SERVICE PANEL
B
JUNCTION BOX,
NEMA-3R
3
THWN-2
EGC: THWN-2 1
6
B
#10
#10
EMT 3/4"
#10
#10
#10
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR SIZE
(AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF
CONDUCTORS
(N) SOLAR LOAD CENTER
MIN., 120/240 V,
M.L.O, NEMA-3R
MLO
YES
7
LOCATION:
20A, 2P
20A, 2P
20A, 2P
SOUTH-WEST
100A
MICROINVERTER MODEL:
IQ7AS-66-ACM-US (240)
NO
15A, 2P
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
PVS6
(3) #14 THWN
(1) #14 THWN EGC
RELOCATED (E) LOADS
FROM MSP TO THIS
LOAD CENTER
PV BREAKER = MODULES x x 1.25 =
RELOCATED BREAKER(S) =
LOAD CENTER FEEDER BREAKER =
NOTE: AFCI BREAKERS REQUIRED IF CIRCUITS
RELOCATED MORE THAN 6 FT.
1.45A
50A, 2P
15A 1P, 15A 1P, 15A 1P, 15A 1P
27 50A, 2P
NO
NO
YES
ACM
NO
NO 1
ROOFTOP
ARRAY WIRING A
DC
AC
DC
AC
DC
AC
1
SUNPOWER MODULES
Branch Circuit #1
Branch Circuit #2
Branch Circuit #3
SPR-A410-G-AC (240)
10 AC MODULES
9 AC MODULES
8 AC MODULES
TAG
PV SYSTEM DISCONNECT
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
NTS
FIGURE A: SINGLE LINE DIAGRAM - 11.07 kW
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
-
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
PVE-1
07/06/2021
ELECTRICAL CALCULATIONS
BRANCH 2 BRANCH 3BRANCH 1
NUMBER OF MODULES
VOLTAGE
RATED AC OUTPUT CURRENT: IOUT =
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE
TEMPERATURE ADDER
TEMPERATURE USED FOR AMPACITY DE-RATING
TEMPERATURE DE-RATING COEFFICIENT
FILL DE-RATING COEFFICIENT
IWIREMIN = IMAX / TEMP_COEFF / FILL_COEFF
WIRE SIZE AMPACITY
CONDUCTOR SIZE
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP
OVERCURRENT PROTECTION
MINIMUM OCPD = IOUT x 1.25
CALCULATED VOLTAGE DROP
ONE WAY CIRCUIT LENGTH
SUBPANEL TO GRID-TIE WIRING
VOLTAGE
SUM OF BRANCHES: IOUT_TOTAL =
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE
TEMPERATURE USED FOR AMPACITY DE-RATING
TEMPERATURE DE-RATING COEFFICIENT
FILL DE-RATING COEFFICIENT
IWIREMIN = IMAX / TEMP_COEFF / FILL_COEFF
WIRE SIZE AMPACITY
CONDUCTOR SIZE
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP
OVERCURRENT PROTECTION
MINIMUM OCPD = IOUT x 1.25
VOLTAGE DROP
ONE WAY CIRCUIT LENGTH
ROOF JCT BOX TO SUBPANEL WIRING #10
9
240 V
13.05 A
16.31 A
47 °C
22 °C
69 °C
0.58
0.8
35.16 A
40 A
#10
#10
0.67%
20A, 2P
16.31 A
#10
10
240 V
14.5 A
18.13 A
47 °C
22 °C
69 °C
0.58
0.8
39.06 A
40 A
#10
#10
0.75%
20A, 2P
18.13 A
#10
8
240 V
11.6 A
14.50 A
47 °C
22 °C
69 °C
0.58
0.8
31.25 A
40 A
#10
#10
0.60%
20A, 2P
14.50 A
50 FT.50 FT.50 FT.
48.94 A
50A, 2P
0.08%
#4
#4
85 A
65.25 A
1.00
0.75
47 °C
47 °C
#4
5 FT.
48.94 A
39.15 A
240 V
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
EL
E
C
T
R
I
C
A
L
C
A
L
C
U
L
A
T
I
O
N
NTS
PVE-2
07/06/2021
1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,
WEATHER RESISTANT AND SUITABLE FOR THE
ENVIRONMENT.
2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH
MINIMUM 3 8" LETTER HEIGHT, WHITE ON RED BACKGROUND.
3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED
ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION
CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER
IS OPERATED.
4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC
CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES,
AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO
AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY
10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS,
AND AT ALL DC COMBINER AND JUNCTION BOXES.
5.DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE
ONLY APPROVED ADHESIVE.
SIGNAGE NOTES
ELECTRICAL DATA & SPECIFICATIONS
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
AMPS
VOLTS
PHOTOVOLTAIC POINT OF
INTERCONNECTION
WARNING: DUAL POWER SOURCE.
SECOND SOURCE IS PHOTOVOLTAIC
SYSTEM
SIGNAGE LOCATIONS:
·MAIN SERVICE PANEL
·INDOOR / OUTDOOR SUBPANEL
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
SIGNAGE LOCATIONS:
·MAIN SERVICE PANEL
PV SOLAR BREAKER
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
SIGNAGE LOCATIONS:
·MAIN SERVICE PANEL
·NEW INDOOR / OUTDOOR LOAD CENTER
·INDOOR / OUTDOOR SUBPANEL
39.15 A
240 V
·
RAPID SHUTDOWN SWITCH FOR
SOLAR PV SYSTEM
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
AND REDUCE SHOCK
HAZARD IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
SIGNAGE LOCATIONS:
·SHALL BE LOCATED ON OR NO MORE THAN 1 M (3 FT)
FROM THE SERVICE DISCONNECTING MEANS TO WHICH
THE PV SYSTEMS ARE CONNECTED.
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
EL
E
C
T
R
I
C
A
L
D
A
T
A
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
NTS
PVE-3
PV SYSTEM
DISCONNECT
SIGNAGE LOCATION:
PV SYSTEM DISCONNECTING
MEANS
07/06/2021
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
N
-
L
C
M
FIGURE 1: SUNPOWER EQUINOX GROUNDING DETAILS NTS
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECT(S)
LOCATED AS SHOWN:
CAUTION:
MAIN SERVICE
PANEL
PHOTOVOLTAIC
ARRAY ON ROOF
SOLAR LOAD
CENTER
FIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
UTILITY METER
45455 DEERBROOK CIRCLE
PVE-4
07/06/2021
R
O
O
F
1
ROOF
2
N
-
L
C
M
A.Dsouza
PROJECT
INSTALLER
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
R E V I S I O N S
SO
L
A
R
I
N
D
I
V
I
D
U
A
L
P
E
R
M
I
T
P
A
C
K
A
G
E
GR
I
D
-
T
I
E
D
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
REV DESCRIPTION DATE DB
DRAWN BY:
DATE DRAWN
SCALE
A ADDED NOTE ON PVA0 6/30/2021 AD
MARKED PV BREAKER
MAIN BREAKER EXISTING PVE1
LE
E
M
E
L
V
I
L
L
E
45
4
5
5
D
E
E
R
B
R
O
O
K
C
I
R
C
L
E
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
5
3
RP-160389
11
.
0
7
k
W
SPRI - ONTARIO
06-05-2021
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
ARUN DSOUZA
BR
A
N
C
H
D
I
A
G
R
A
M
3/32" = 1'-0"
INSTALLER NAME:
_____________________
BRANCH VOLTAGES:
1.
2.
3.
4.
5.
6.
1 2ROOF
AZIMUTH
PITCH
MODULE
QTY.
3:12
339°
19
3:12
249°
8
N
PVE-5
FIGURE 1: PV MODULE SPECIFICATION SHEET FIGURE 2: PV MODULE SPECIFICATION SHEET SHEET
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
REV DESCRIPTION DATE DB CB
R E V I S I O N S
FI
L
E
:
S
P
_
S
t
a
n
d
a
r
d
_
W
o
r
k
i
n
g
_
D
r
a
w
i
n
g
_
S
P
D
_
V
3
_
(
X
r
e
f
'
d
)
(
1
)
.
d
w
g
,
U
S
E
R
:
a
l
b
l
a
n
c
o
,
D
A
T
E
/
T
I
M
E
:
J
a
n
1
5
,
2
0
2
0
-
1
2
:
3
8
a
m
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
FIGURE 1: PEGASUS SOLAR MOUNTING DATA SHEET FIGURE 2: PEGASUS SOLAR MOUNTING DATA SHEET
FI
L
E
:
P
e
g
a
s
u
s
S
o
l
a
r
_
S
P
E
C
S
H
E
E
T
S
.
d
w
g
,
U
S
E
R
:
r
e
u
d
e
,
D
A
T
E
/
T
I
M
E
:
M
a
r
2
0
,
2
0
1
7
-
7
:
4
3
p
m
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
NTS
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR CERTIFICATION LETTER
FI
L
E
:
S
P
D
_
P
S
_
S
P
E
C
S
H
E
E
T
S
.
d
w
g
,
U
S
E
R
:
r
e
u
d
e
,
D
A
T
E
/
T
I
M
E
:
M
a
r
2
0
,
2
0
1
7
-
7
:
3
0
p
m
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
NTS
FIGURE 1: PEGASUS SOLAR CERTIFICATION LETTER FIGURE 2: PEGASUS SOLAR TEST VERIFICATION OF CONFORMITY
FI
L
E
:
P
e
g
a
s
u
s
S
o
l
a
r
_
S
P
E
C
S
H
E
E
T
S
.
d
w
g
,
U
S
E
R
:
r
e
u
d
e
,
D
A
T
E
/
T
I
M
E
:
M
a
r
2
0
,
2
0
1
7
-
7
:
4
4
p
m
SHEET
REV DESCRIPTION DATE DB CB
R E V I S I O N S
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
SCALE
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
NTS
FIGURE 2: INVISIMOUNT DATASHEETFIGURE 1: INVISIMOUNT DATA SHEET SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
R E V I S I O N S
REV DESCRIPTION DATE DB CB
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
PROJECT
OPPORTUNITY
FIGURE 1: PVS6 SPECIFICATION SHEET FIGURE 1: PVS6 SPECIFICATION SHEET
SHEET
DRAWN BY
DATE DRAWN
DATE CHECKED
SCALE
CHECKED BY
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(
5
1
0
)
5
4
0
-
0
5
5
0
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
R E V I S I O N S
REV DESCRIPTION DATE DB CB
C
A
L
I
C
E
N
S
E
#
8
9
0
8
9
5
PROJECT
OPPORTUNITY