BRES2021-0411 -Title 24 - Revision 2CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 1 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
GENERAL INFORMATION
01 Project Name Madison Lot 59A
02 Run Title Title 24 Analysis
03 Project Location Lot 59A
04 City La Quinta 05 Standards Version 2019
06 Zip code 92253 07 Software Version EnergyPro 8.2
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)0
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 6
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.35
18 Total Cond. Floor Area (ft
2)9801 19 Glazing Percentage (%)26.20%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Is Natural Gas Available?Yes
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 2 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
ENERGY DESIGN RATING
Energy Design Ratings Compliance Margins
Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR)
Standard Design 40.9 21.2
Proposed Design 36.6 18 4.3 3.2
RESULT:3:COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
•Standard Design PV Capacity: 12.35 kWdc
ENERGY USE SUMMARY
Energy Use (kTDV/ft
2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 2.51 5.1 -2.59 -103.2
Space Cooling 74.56 61.94 12.62 16.9
IAQ Ventilation 1.87 1.87 0 0
Water Heating 2.4 2.25 0.15 6.3
Self Utilization/Flexibility Credit n/a 0 0 n/a
Compliance Energy Total 81.34 71.16 10.18 12.5
REQUIRED PV SYSTEMS - SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
12.35 NA Standard Fixed none false 180 Degre
es 5 1.05 96 100
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 3 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Cool roof
•Insulation below roof deck
•Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
•Quality insulation installation (QII)
•Indoor air quality ventilation
Cooling System Verifications:
•Minimum Airflow
•Verified EER
•Verified SEER
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
Heating System Verifications:
•Verified HSPF
•Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
•Duct leakage testing
•Low-leakage Air Handling Unit
Domestic Hot Water System Verifications:
•-- None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Madison Lot 59A 9801 1 6 6 0 1
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 4 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Master #1 Conditioned AC #71 1696 10.8 DHW Sys 1 N/A
bedroom 3/Utility Conditioned AC #52 1062 10 DHW Sys 1 N/A
Great Room/Kitchen Conditioned AC #3 & 63 2272 13.5 DHW Sys 1 N/A
Master #2 Conditioned AC #24 1675 11 DHW Sys 1 N/A
Foyer/Flex Conditioned AC #45 1360 13.5 DHW Sys 1 N/A
Guest Suite Conditioned AC #16 1736 10.5 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
N Wall Master #1 R-21 Wall 0 Front 190 0 90
E Wall Master #1 R-21 Wall 90 Left 688 185.8 90
S Wall Master #1 R-21 Wall 180 Back 286 210 90
W Wall Master #1 R-21 Wall 270 Right 288 66 90
N Wall 2 bedroom 3/Utility R-21 Wall 0 Front 260 24 90
E Wall 2 bedroom 3/Utility R-21 Wall 90 Left 290 80.5 90
W Wall 2 bedroom 3/Utility R-21 Wall 270 Right 100 16 90
E Wall 3 Great Room/Kitchen R-21 Wall 90 Left 100 60 90
S Wall 2 Great Room/Kitchen R-21 Wall 180 Back 630 560 90
N Wall 3 Master #2 R-21 Wall 0 Front 90 0 90
S Wall 3 Master #2 R-21 Wall 180 Back 288 150 90
W Wall 3 Master #2 R-21 Wall 270 Right 704 197.5 90
N Wall 4 Foyer/Flex R-21 Wall 0 Front 410 375 90
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 5 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
E Wall 4 Foyer/Flex R-21 Wall 90 Left 124.1 124 90
W Wall 4 Foyer/Flex R-21 Wall 270 Right 215 121.5 90
N Wall 5 Guest Suite R-21 Wall 0 Front 350 34 90
E Wall 5 Guest Suite R-21 Wall 90 Left 702 79 90
S Wall 4 Guest Suite R-21 Wall 180 Back 352 115 90
W Wall 5 Guest Suite R-21 Wall 270 Right 702 193.5 90
Interior Surface
Master #1>>Great
Room/Kitchen R-0 Interior Wall n/a n/a 500 0 n/a
Interior Surface 2
bedroom
3/Utility>>Foyer/Flex R-0 Interior Wall n/a n/a 280 0 n/a
Interior Surface 3
bedroom
3/Utility>>Great
Room/Kitchen
R-0 Interior Wall n/a n/a 260 0 n/a
Interior Surface 4
Great
Room/Kitchen>>Master
#1
R-0 Interior Wall n/a n/a 500 0 n/a
Interior Surface 5
Great
Room/Kitchen>>bedro
om 3/Utility
R-0 Interior Wall n/a n/a 260 0 n/a
Interior Surface 6
Great
Room/Kitchen>>Master
#2
R-0 Interior Wall n/a n/a 529 0 n/a
Interior Surface 7
Master #2>>Great
Room/Kitchen R-0 Interior Wall n/a n/a 529 0 n/a
Interior Surface 8 Master #2>>Foyer/Flex R-0 Interior Wall n/a n/a 350 0 n/a
Interior Surface 9 Foyer/Flex>>Master #2 R-0 Interior Wall n/a n/a 350 0 n/a
Interior Surface 10
Foyer/Flex>>bedroom
3/Utility R-0 Interior Wall n/a n/a 280 0 n/a
Interior Surface 11
Foyer/Flex>>Guest
Suite R-0 Interior Wall n/a n/a 140 0 n/a
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 6 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Interior Surface 12
Guest
Suite>>Foyer/Flex R-0 Interior Wall n/a n/a 140 0 n/a
Roof Master #1 R-38 Pitched Roof w/ R-1 n/a n/a 1696 n/a n/a
Roof 2 bedroom 3/Utility R-38 Pitched Roof w/ R-1 n/a n/a 1062 n/a n/a
Roof 3 Great Room/Kitchen R-38 Pitched Roof w/ R-1 n/a n/a 2272 n/a n/a
Roof 4 Master #2 R-38 Pitched Roof w/ R-1 n/a n/a 1675 n/a n/a
Roof 5 Foyer/Flex R-38 Pitched Roof w/ R-1 n/a n/a 1360 n/a n/a
Roof 6 Guest Suite R-38 Pitched Roof w/ R-1 n/a n/a 1736 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Master #1 Attic RoofMaster #1 Unventilated 3 0.81 0.91 No Yes
Attic bedroom 3/Utility
Attic Roofbedroom
3/Utility Unventilated 3 0.81 0.91 No Yes
Attic Great
Room/Kitchen
Attic RoofGreat
Room/Kitchen Unventilated 3 0.81 0.91 No Yes
Attic Master #2 Attic RoofMaster #2 Unventilated 3 0.81 0.91 No Yes
Attic Foyer/Flex Attic RoofFoyer/Flex Unventilated 3 0.81 0.91 No Yes
Attic Guest Suite Attic RoofGuest Suite Unventilated 3 0.81 0.91 No Yes
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
L Window E Wall Left 90 1 6.3 0.3 NFRC 0.2 NFRC Bug Screen
K Window E Wall Left 90 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 7 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
J Window E Wall Left 90 1 22.5 0.3 NFRC 0.2 NFRC Bug Screen
I Window E Wall Left 90 1 90 0.3 NFRC 0.2 NFRC Bug Screen
H Window E Wall Left 90 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen
G Window E Wall Left 90 1 42 0.3 NFRC 0.2 NFRC Bug Screen
7 Window S Wall Back 180 17.5 12 1 210 0.39 NFRC 0.23 NFRC Bug Screen
6 Window W Wall Right 270 5.5 12 1 66 0.39 NFRC 0.23 NFRC Bug Screen
Q Window E Wall 2 Left 90 1 22.5 0.3 NFRC 0.2 NFRC Bug Screen
P Window E Wall 2 Left 90 1 8 0.3 NFRC 0.2 NFRC Bug Screen
N Window E Wall 2 Left 90 1 50 0.3 NFRC 0.2 NFRC Bug Screen
U Window W Wall 2 Right 270 1 16 0.3 NFRC 0.2 NFRC Bug Screen
M Window E Wall 3 Left 90 1 60 0.3 NFRC 0.2 NFRC Bug Screen
5 Window S Wall 2 Back 180 40 14 1 560 0.39 NFRC 0.23 NFRC Bug Screen
4 Window S Wall 3 Back 180 15 10 1 150 0.39 NFRC 0.23 NFRC Bug Screen
F Window W Wall 3 Right 270 1 24 0.3 NFRC 0.2 NFRC Bug Screen
E1 Window W Wall 3 Right 270 1 30 0.3 NFRC 0.2 NFRC Bug Screen
E Window W Wall 3 Right 270 1 21 0.3 NFRC 0.2 NFRC Bug Screen
D Window W Wall 3 Right 270 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen
C Window W Wall 3 Right 270 1 60 0.3 NFRC 0.2 NFRC Bug Screen
B Window W Wall 3 Right 270 1 50 0.3 NFRC 0.2 NFRC Bug Screen
3 Window N Wall 4 Front 0 1 115 0.39 NFRC 0.23 NFRC Bug Screen
1 Window N Wall 4 Front 0 20 10 1 200 0.39 NFRC 0.23 NFRC Bug Screen
V Window N Wall 4 Front 0 20 3 1 60 0.3 NFRC 0.2 NFRC Bug Screen
2 Window E Wall 4 Left 90 1 55 0.39 NFRC 0.23 NFRC Bug Screen
Y Window E Wall 4 Left 90 1 69 0.3 NFRC 0.2 NFRC Bug Screen
A Window W Wall 4 Right 270 1 52.5 0.3 NFRC 0.2 NFRC Bug Screen
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 8 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
X Window W Wall 4 Right 270 1 69 0.3 NFRC 0.2 NFRC Bug Screen
GB Window N Wall 5 Front 0 1 20 0.3 NFRC 0.2 NFRC Bug Screen
GA Window N Wall 5 Front 0 1 14 0.3 NFRC 0.2 NFRC Bug Screen
G2 Window E Wall 5 Left 90 3 8 1 24 0.39 NFRC 0.23 NFRC Bug Screen
G3 Window E Wall 5 Left 90 1 55 0.39 NFRC 0.23 NFRC Bug Screen
G4 Window S Wall 4 Back 180 1 115 0.3 NFRC 0.2 NFRC Bug Screen
GJ Window W Wall 5 Right 270 1 10 0.3 NFRC 0.2 NFRC Bug Screen
GH Window W Wall 5 Right 270 1 28 0.3 NFRC 0.2 NFRC Bug Screen
GG Window W Wall 5 Right 270 1 28 0.3 NFRC 0.2 NFRC Bug Screen
GF Window W Wall 5 Right 270 1 32.5 0.3 NFRC 0.2 NFRC Bug Screen
GE Window W Wall 5 Right 270 1 32.5 0.3 NFRC 0.2 NFRC Bug Screen
GD Window W Wall 5 Right 270 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen
GC Window W Wall 5 Right 270 1 50 0.3 NFRC 0.2 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door 13 N Wall 2 24 0.5
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
7 10 0.1 10 10 0 0 0 0 0 0 0 0 0
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 9 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
6 8 0.1 8 8 0 0 0 0 0 0 0 0 0
5 25 0.1 25 25 0 0 0 0 0 0 0 0 0
4 8 0.1 8 8 0 0 0 0 0 0 0 0 0
1 4 0.1 4 4 0 0 0 0 0 0 0 0 0
V 4 0.1 4 4 0 0 0 0 0 0 0 0 0
G2 10 0.1 10 10 0 0 0 0 0 0 0 0 0
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab Master #1 1696 132 none 0 80%No
Slab 2 bedroom 3/Utility 1062 76 none 0 80%No
Slab 3 Great Room/Kitchen 2272 53 none 0 80%No
Slab 4 Master #2 1675 93 none 0 80%No
Slab 5 Foyer/Flex 1360 62 none 0 80%No
Slab 6 Guest Suite 1736 201 none 0 80%No
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 10 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Attic RoofMaster #1 Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Attic Roofbedroom
3/Utility Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Attic RoofGreat
Room/Kitchen Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Attic RoofMaster #2 Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 11 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofFoyer/Flex Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
Attic RoofGuest Suite Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-6.0 insul.
R-38 Pitched Roof w/
R-1
Ceilings (below
attic)
Wood Framed
Ceiling 2x6 @ 16 in. O. C.R-38 None / None 0.026
Over Ceiling Joists: R-23.7 insul.
Cavity / Frame: R-14.3 / 2x6
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System DHW Heater 1 (2)n/a None n/a
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 12 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type
# of
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff
1st Hr. Rating
or Flow Rate
NEEA Heat Pump
Brand or Model
Tank Location or
Ambient Condition
DHW Heater 1 Gas Consumer
Instantaneous 2 0 0.98-UEF 200000-
Btu/Hr 0 n/a n/a n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
AC #71 Heat pump heating cooling
Heat Pump
System 1
Heat Pump
System 1
HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
AC #52 Heat pump heating cooling
Heat Pump
System 2
Heat Pump
System 2
HVAC Fan 2
Air
Distribution
System 2
Setback New NA 1 1
AC #3 & 63 Heat pump heating cooling
Heat Pump
System 3
Heat Pump
System 3
HVAC Fan 3
Air
Distribution
System 3
Setback New NA 2 2
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 13 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type
Heating Unit
Name
Cooling Unit
Name Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
AC #24 Heat pump heating cooling
Heat Pump
System 4
Heat Pump
System 4
HVAC Fan 4
Air
Distribution
System 4
Setback New NA 1 1
AC #45 Heat pump heating cooling
Heat Pump
System 5
Heat Pump
System 5
HVAC Fan 5
Air
Distribution
System 5
Setback New NA 1 1
AC #16 Heat pump heating cooling
Heat Pump
System 6
Heat Pump
System 6
HVAC Fan 6
Air
Distribution
System 6
Setback New NA 1 1
01 02 03 04 05 06 07 08 09 10 11
HVAC - HEAT PUMPS
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER/CEER
Heat Pump System 1 Central split HP 1 10 60000 39000 18 12.5 Not Zonal
Single
Speed
Heat Pump System
1-hers-htpump
Heat Pump System 2 Central split HP 1 10 48000 31200 18 13 Not Zonal
Single
Speed
Heat Pump System
2-hers-htpump
Heat Pump System 3 Central split HP 2 10 60000 39000 18 12.5 Not Zonal
Single
Speed
Heat Pump System
3-hers-htpump
Heat Pump System 4 Central split HP 1 10 60000 39000 18 12.5 Not Zonal
Single
Speed
Heat Pump System
4-hers-htpump
Heat Pump System 5 Central split HP 1 10 48000 31200 18 13 Not Zonal
Single
Speed
Heat Pump System
5-hers-htpump
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 14 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
01 02 03 04 05 06 07 08 09 10 11
HVAC - HEAT PUMPS
Name System Type Number of Units
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER/CEER
Heat Pump System 6 Central split HP 1 10 60000 39000 18 12.5 Not Zonal
Single
Speed
Heat Pump System
6-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge Verified HSPF
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
2-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
3-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
4-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
5-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
6-hers-htpump Required 350 Required Required Yes Yes Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
Air Distribution
System 1
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 15 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins. R-value Duct Location Surface Area
Name Type Design Type Supply Return Supply Return Supply Return Bypass
Duct Duct Leakage
HERS
Verification
System
1-hers-dist
Air Distribution
System 2
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
2-hers-dist
Air Distribution
System 3
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
3-hers-dist
Air Distribution
System 4
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
4-hers-dist
Air Distribution
System 5
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
5-hers-dist
Air Distribution
System 6
Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Air
Distribution
System
6-hers-dist
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 16 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 2-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 3-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 4-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 5-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
Air Distribution
System 6-hers-dist
Yes 6.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan
HVAC Fan 3 HVAC Fan 0.45 HVAC Fan 3-hers-fan
HVAC Fan 4 HVAC Fan 0.45 HVAC Fan 4-hers-fan
HVAC Fan 5 HVAC Fan 0.45 HVAC Fan 5-hers-fan
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 17 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 6 HVAC Fan 0.45 HVAC Fan 6-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
HVAC Fan 2-hers-fan Required 0.45
HVAC Fan 3-hers-fan Required 0.45
HVAC Fan 4-hers-fan Required 0.45
HVAC Fan 5-hers-fan Required 0.45
HVAC Fan 6-hers-fan Required 0.45
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%)
IAQ Recovery Effectiveness -
SREIAQ Recovery Effectiveness
- SRE
SFam IAQVentRpt 312 0.25 Default 0 n/a
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 18 of 18)
Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300
Schema Version: rev 20200901
Report Generated: 2021-09-01 14:04:26
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Tim Scott
Scott Design and Title 24, Inc.
77085 Michigan Drive
Palm Desert, CA 92211
2021-09-01 14:18:35
760-200-4780
Tim Scott
Scott Design and Title 24, Inc.
77085 Michigan Drive
Palm Desert, CA 92211
2021-09-01 14:18:35
na
760-200-4780
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.