Loading...
BRES2021-0411 -Title 24 - Revision 2CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 1 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 GENERAL INFORMATION 01 Project Name Madison Lot 59A 02 Run Title Title 24 Analysis 03 Project Location Lot 59A 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 6 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.35 18 Total Cond. Floor Area (ft 2)9801 19 Glazing Percentage (%)26.20% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 2 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency¹ (EDR)Total² (EDR)Efficiency¹ (EDR)Total² (EDR) Standard Design 40.9 21.2 Proposed Design 36.6 18 4.3 3.2 RESULT:3:COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero •Standard Design PV Capacity: 12.35 kWdc ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.51 5.1 -2.59 -103.2 Space Cooling 74.56 61.94 12.62 16.9 IAQ Ventilation 1.87 1.87 0 0 Water Heating 2.4 2.25 0.15 6.3 Self Utilization/Flexibility Credit n/a 0 0 n/a Compliance Energy Total 81.34 71.16 10.18 12.5 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 12.35 NA Standard Fixed none false 180 Degre es 5 1.05 96 100 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 3 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Insulation below roof deck •Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •Quality insulation installation (QII) •Indoor air quality ventilation Cooling System Verifications: •Minimum Airflow •Verified EER •Verified SEER •Verified Refrigerant Charge •Fan Efficacy Watts/CFM Heating System Verifications: •Verified HSPF •Verified heat pump rated heating capacity HVAC Distribution System Verifications: •Duct leakage testing •Low-leakage Air Handling Unit Domestic Hot Water System Verifications: •-- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Lot 59A 9801 1 6 6 0 1 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 4 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master #1 Conditioned AC #71 1696 10.8 DHW Sys 1 N/A bedroom 3/Utility Conditioned AC #52 1062 10 DHW Sys 1 N/A Great Room/Kitchen Conditioned AC #3 & 63 2272 13.5 DHW Sys 1 N/A Master #2 Conditioned AC #24 1675 11 DHW Sys 1 N/A Foyer/Flex Conditioned AC #45 1360 13.5 DHW Sys 1 N/A Guest Suite Conditioned AC #16 1736 10.5 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) N Wall Master #1 R-21 Wall 0 Front 190 0 90 E Wall Master #1 R-21 Wall 90 Left 688 185.8 90 S Wall Master #1 R-21 Wall 180 Back 286 210 90 W Wall Master #1 R-21 Wall 270 Right 288 66 90 N Wall 2 bedroom 3/Utility R-21 Wall 0 Front 260 24 90 E Wall 2 bedroom 3/Utility R-21 Wall 90 Left 290 80.5 90 W Wall 2 bedroom 3/Utility R-21 Wall 270 Right 100 16 90 E Wall 3 Great Room/Kitchen R-21 Wall 90 Left 100 60 90 S Wall 2 Great Room/Kitchen R-21 Wall 180 Back 630 560 90 N Wall 3 Master #2 R-21 Wall 0 Front 90 0 90 S Wall 3 Master #2 R-21 Wall 180 Back 288 150 90 W Wall 3 Master #2 R-21 Wall 270 Right 704 197.5 90 N Wall 4 Foyer/Flex R-21 Wall 0 Front 410 375 90 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 5 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) E Wall 4 Foyer/Flex R-21 Wall 90 Left 124.1 124 90 W Wall 4 Foyer/Flex R-21 Wall 270 Right 215 121.5 90 N Wall 5 Guest Suite R-21 Wall 0 Front 350 34 90 E Wall 5 Guest Suite R-21 Wall 90 Left 702 79 90 S Wall 4 Guest Suite R-21 Wall 180 Back 352 115 90 W Wall 5 Guest Suite R-21 Wall 270 Right 702 193.5 90 Interior Surface Master #1>>Great Room/Kitchen R-0 Interior Wall n/a n/a 500 0 n/a Interior Surface 2 bedroom 3/Utility>>Foyer/Flex R-0 Interior Wall n/a n/a 280 0 n/a Interior Surface 3 bedroom 3/Utility>>Great Room/Kitchen R-0 Interior Wall n/a n/a 260 0 n/a Interior Surface 4 Great Room/Kitchen>>Master #1 R-0 Interior Wall n/a n/a 500 0 n/a Interior Surface 5 Great Room/Kitchen>>bedro om 3/Utility R-0 Interior Wall n/a n/a 260 0 n/a Interior Surface 6 Great Room/Kitchen>>Master #2 R-0 Interior Wall n/a n/a 529 0 n/a Interior Surface 7 Master #2>>Great Room/Kitchen R-0 Interior Wall n/a n/a 529 0 n/a Interior Surface 8 Master #2>>Foyer/Flex R-0 Interior Wall n/a n/a 350 0 n/a Interior Surface 9 Foyer/Flex>>Master #2 R-0 Interior Wall n/a n/a 350 0 n/a Interior Surface 10 Foyer/Flex>>bedroom 3/Utility R-0 Interior Wall n/a n/a 280 0 n/a Interior Surface 11 Foyer/Flex>>Guest Suite R-0 Interior Wall n/a n/a 140 0 n/a 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 6 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Interior Surface 12 Guest Suite>>Foyer/Flex R-0 Interior Wall n/a n/a 140 0 n/a Roof Master #1 R-38 Pitched Roof w/ R-1 n/a n/a 1696 n/a n/a Roof 2 bedroom 3/Utility R-38 Pitched Roof w/ R-1 n/a n/a 1062 n/a n/a Roof 3 Great Room/Kitchen R-38 Pitched Roof w/ R-1 n/a n/a 2272 n/a n/a Roof 4 Master #2 R-38 Pitched Roof w/ R-1 n/a n/a 1675 n/a n/a Roof 5 Foyer/Flex R-38 Pitched Roof w/ R-1 n/a n/a 1360 n/a n/a Roof 6 Guest Suite R-38 Pitched Roof w/ R-1 n/a n/a 1736 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master #1 Attic RoofMaster #1 Unventilated 3 0.81 0.91 No Yes Attic bedroom 3/Utility Attic Roofbedroom 3/Utility Unventilated 3 0.81 0.91 No Yes Attic Great Room/Kitchen Attic RoofGreat Room/Kitchen Unventilated 3 0.81 0.91 No Yes Attic Master #2 Attic RoofMaster #2 Unventilated 3 0.81 0.91 No Yes Attic Foyer/Flex Attic RoofFoyer/Flex Unventilated 3 0.81 0.91 No Yes Attic Guest Suite Attic RoofGuest Suite Unventilated 3 0.81 0.91 No Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading L Window E Wall Left 90 1 6.3 0.3 NFRC 0.2 NFRC Bug Screen K Window E Wall Left 90 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 7 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading J Window E Wall Left 90 1 22.5 0.3 NFRC 0.2 NFRC Bug Screen I Window E Wall Left 90 1 90 0.3 NFRC 0.2 NFRC Bug Screen H Window E Wall Left 90 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen G Window E Wall Left 90 1 42 0.3 NFRC 0.2 NFRC Bug Screen 7 Window S Wall Back 180 17.5 12 1 210 0.39 NFRC 0.23 NFRC Bug Screen 6 Window W Wall Right 270 5.5 12 1 66 0.39 NFRC 0.23 NFRC Bug Screen Q Window E Wall 2 Left 90 1 22.5 0.3 NFRC 0.2 NFRC Bug Screen P Window E Wall 2 Left 90 1 8 0.3 NFRC 0.2 NFRC Bug Screen N Window E Wall 2 Left 90 1 50 0.3 NFRC 0.2 NFRC Bug Screen U Window W Wall 2 Right 270 1 16 0.3 NFRC 0.2 NFRC Bug Screen M Window E Wall 3 Left 90 1 60 0.3 NFRC 0.2 NFRC Bug Screen 5 Window S Wall 2 Back 180 40 14 1 560 0.39 NFRC 0.23 NFRC Bug Screen 4 Window S Wall 3 Back 180 15 10 1 150 0.39 NFRC 0.23 NFRC Bug Screen F Window W Wall 3 Right 270 1 24 0.3 NFRC 0.2 NFRC Bug Screen E1 Window W Wall 3 Right 270 1 30 0.3 NFRC 0.2 NFRC Bug Screen E Window W Wall 3 Right 270 1 21 0.3 NFRC 0.2 NFRC Bug Screen D Window W Wall 3 Right 270 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen C Window W Wall 3 Right 270 1 60 0.3 NFRC 0.2 NFRC Bug Screen B Window W Wall 3 Right 270 1 50 0.3 NFRC 0.2 NFRC Bug Screen 3 Window N Wall 4 Front 0 1 115 0.39 NFRC 0.23 NFRC Bug Screen 1 Window N Wall 4 Front 0 20 10 1 200 0.39 NFRC 0.23 NFRC Bug Screen V Window N Wall 4 Front 0 20 3 1 60 0.3 NFRC 0.2 NFRC Bug Screen 2 Window E Wall 4 Left 90 1 55 0.39 NFRC 0.23 NFRC Bug Screen Y Window E Wall 4 Left 90 1 69 0.3 NFRC 0.2 NFRC Bug Screen A Window W Wall 4 Right 270 1 52.5 0.3 NFRC 0.2 NFRC Bug Screen 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 8 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading X Window W Wall 4 Right 270 1 69 0.3 NFRC 0.2 NFRC Bug Screen GB Window N Wall 5 Front 0 1 20 0.3 NFRC 0.2 NFRC Bug Screen GA Window N Wall 5 Front 0 1 14 0.3 NFRC 0.2 NFRC Bug Screen G2 Window E Wall 5 Left 90 3 8 1 24 0.39 NFRC 0.23 NFRC Bug Screen G3 Window E Wall 5 Left 90 1 55 0.39 NFRC 0.23 NFRC Bug Screen G4 Window S Wall 4 Back 180 1 115 0.3 NFRC 0.2 NFRC Bug Screen GJ Window W Wall 5 Right 270 1 10 0.3 NFRC 0.2 NFRC Bug Screen GH Window W Wall 5 Right 270 1 28 0.3 NFRC 0.2 NFRC Bug Screen GG Window W Wall 5 Right 270 1 28 0.3 NFRC 0.2 NFRC Bug Screen GF Window W Wall 5 Right 270 1 32.5 0.3 NFRC 0.2 NFRC Bug Screen GE Window W Wall 5 Right 270 1 32.5 0.3 NFRC 0.2 NFRC Bug Screen GD Window W Wall 5 Right 270 1 12.5 0.3 NFRC 0.2 NFRC Bug Screen GC Window W Wall 5 Right 270 1 50 0.3 NFRC 0.2 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door 13 N Wall 2 24 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 7 10 0.1 10 10 0 0 0 0 0 0 0 0 0 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 9 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 6 8 0.1 8 8 0 0 0 0 0 0 0 0 0 5 25 0.1 25 25 0 0 0 0 0 0 0 0 0 4 8 0.1 8 8 0 0 0 0 0 0 0 0 0 1 4 0.1 4 4 0 0 0 0 0 0 0 0 0 V 4 0.1 4 4 0 0 0 0 0 0 0 0 0 G2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab Master #1 1696 132 none 0 80%No Slab 2 bedroom 3/Utility 1062 76 none 0 80%No Slab 3 Great Room/Kitchen 2272 53 none 0 80%No Slab 4 Master #2 1675 93 none 0 80%No Slab 5 Foyer/Flex 1360 62 none 0 80%No Slab 6 Guest Suite 1736 201 none 0 80%No 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 10 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.277 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Attic RoofMaster #1 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic Roofbedroom 3/Utility Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic RoofGreat Room/Kitchen Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic RoofMaster #2 Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 11 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofFoyer/Flex Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. Attic RoofGuest Suite Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / None 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. R-38 Pitched Roof w/ R-1 Ceilings (below attic) Wood Framed Ceiling 2x6 @ 16 in. O. C.R-38 None / None 0.026 Over Ceiling Joists: R-23.7 insul. Cavity / Frame: R-14.3 / 2x6 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#)Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2)n/a None n/a 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 12 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition DHW Heater 1 Gas Consumer Instantaneous 2 0 0.98-UEF 200000- Btu/Hr 0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count AC #71 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback New NA 1 1 AC #52 Heat pump heating cooling Heat Pump System 2 Heat Pump System 2 HVAC Fan 2 Air Distribution System 2 Setback New NA 1 1 AC #3 & 63 Heat pump heating cooling Heat Pump System 3 Heat Pump System 3 HVAC Fan 3 Air Distribution System 3 Setback New NA 2 2 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 13 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count AC #24 Heat pump heating cooling Heat Pump System 4 Heat Pump System 4 HVAC Fan 4 Air Distribution System 4 Setback New NA 1 1 AC #45 Heat pump heating cooling Heat Pump System 5 Heat Pump System 5 HVAC Fan 5 Air Distribution System 5 Setback New NA 1 1 AC #16 Heat pump heating cooling Heat Pump System 6 Heat Pump System 6 HVAC Fan 6 Air Distribution System 6 Setback New NA 1 1 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 1 10 60000 39000 18 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump Heat Pump System 2 Central split HP 1 10 48000 31200 18 13 Not Zonal Single Speed Heat Pump System 2-hers-htpump Heat Pump System 3 Central split HP 2 10 60000 39000 18 12.5 Not Zonal Single Speed Heat Pump System 3-hers-htpump Heat Pump System 4 Central split HP 1 10 60000 39000 18 12.5 Not Zonal Single Speed Heat Pump System 4-hers-htpump Heat Pump System 5 Central split HP 1 10 48000 31200 18 13 Not Zonal Single Speed Heat Pump System 5-hers-htpump 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 14 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 6 Central split HP 1 10 60000 39000 18 12.5 Not Zonal Single Speed Heat Pump System 6-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 2-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 3-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 4-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 5-hers-htpump Required 350 Required Required Yes Yes Yes Yes Heat Pump System 6-hers-htpump Required 350 Required Required Yes Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 15 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification System 1-hers-dist Air Distribution System 2 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 2-hers-dist Air Distribution System 3 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 3-hers-dist Air Distribution System 4 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 4-hers-dist Air Distribution System 5 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 5-hers-dist Air Distribution System 6 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 6-hers-dist 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 16 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 2-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 3-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 4-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 5-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No Air Distribution System 6-hers-dist Yes 6.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.45 HVAC Fan 3-hers-fan HVAC Fan 4 HVAC Fan 0.45 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.45 HVAC Fan 5-hers-fan 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 17 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 6 HVAC Fan 0.45 HVAC Fan 6-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 HVAC Fan 2-hers-fan Required 0.45 HVAC Fan 3-hers-fan Required 0.45 HVAC Fan 4-hers-fan Required 0.45 HVAC Fan 5-hers-fan Required 0.45 HVAC Fan 6-hers-fan Required 0.45 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness - SRE SFam IAQVentRpt 312 0.25 Default 0 n/a 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:Madison Lot 59A Calculation Date/Time:2021-09-01T14:01:43-07:00 (Page 18 of 18) Calculation Description:Title 24 Analysis Input File Name:Madison Lot 59A-Radford-20.ribd19x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.300 Schema Version: rev 20200901 Report Generated: 2021-09-01   14:04:26 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Drive Palm Desert, CA 92211 2021-09-01 14:18:35 760-200-4780 Tim Scott Scott Design and Title 24, Inc. 77085 Michigan Drive Palm Desert, CA 92211 2021-09-01 14:18:35 na 760-200-4780 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 221-P010183591A-000-000-0000000-0000 2021-09-01 14:18:35 CalCERTS inc.