BSOL2021-0201BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type:
Solar
Permit Number:
BSOL2021-0201
Property Address:
81359 PEARY PL
APN:
767680021
Legal Description
Property Zoning:
Valuation:
$38,903.00
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 10/27/2021
ISSUED DATE: 12/28/2021
CALIFORNIA
Owner: REYES PARTNERSHIP 4
P O BOX 8751, RANCHO SANTE FE, CA 92067
Applicant: CARMEN MESHACK
45350 SAN LUIS REY, PALM DESERT, CA 92260
Contractor: CARMEN MESHACK / 988895
45350 SAN LUIS REY, PALM DESERT, CA 92260
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors' State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors' State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors' State License Law does not apply to an owner of
property who, through employees' or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner -Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors' State License Law.
As an Owner -Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner -builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS' COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
1) Has and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers' compensation laws of California, and agree that, if should
become subject to the workers' compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above -mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 5/23/25 11:39 am Page 1 of 3
Permit Type: Solar
BUILDING PERMIT
Permit Number:
Property Address
BSOL2021-0201
81359 PEARY PL
DOAN/ 12.35kW PV SYSTEM - (38) 325W PANELS W/ MICROINVERTERS *** 12.35kW SOLAR ARRAY - (38) 325W REC SOLAR
REC325TP3M BLACK PANELS W/ (38) ENPHASE IQ7PLUS-72-2-US MICROINVERTERS + 125A IQ COMBINER 3 BOX [760SF] 2019
CALIFORNIA BUILDING CODES. #111# DOAN/ 12.35kW PV SYSTEM - (38) 325W PANELS W/ MICROINVERTERS *** REVISION 2 -
REVISED PANEL WATTAGE 325W TO 365W FOR A SYSTEM SIZE OF 13.87KW [PROCTOR ENGINEERING]. NO OTHER CHANGES TO
SYSTEM. 2019 CALIFORNIA BUILDING CODES. #111# DOAN/ 12.35kW PV SYSTEM - (38) 325W PANELS W/ MICROINVERTERS "
REVISION 1 - REVISED ROOFTOP LAYOUT + UPDATED CONDUCTOR SIZES.
System Size (kW DC) 12.35 PV Strings (EA) 3 PV Miscellaneous 1
Equipment EA
Type Group Sq Ft Value
Invoice No. Fee
PERMIT-BSOL2021-020 PV SYSTEM GREATER THAN 10KW
1 PV SYSTEM MISC EQUIPMENT PC
HOURLY CHARGE - CITY BUILDING STAFF
PV SYSTEM MISC EQUIPMENT
PV SYSTEM GREATER THAN 10KW PC
BSAS SB1473 FEE
RECORDS MANAGEMENT FEE
PAYMENT OVER COLLECTED
PERMIT ISSUANCE
TECHNOLOGY ENHANCEMENT FEE
Total for Invoice PERMIT-BSOL2021-0201
Fee Amount
Amount Paid
$41.68
$41.68
$27.79
$27.79
$334.00
$334.00
$27.79
$27.79
$41.68
$41.68
$2.00
$2.00
$11.00
$11.00
$0.00
$0.00
$105.60
$105.60
$5.00
$5.00
$596.54
$596.54
Grand Total for Permit $596.54 $596.54
Workflow Step / Action Name
Action Type Start Date End Date
Inspections v.1
10/27/2021 0:00
------------------------------------------------
SOLAR FINAL** v.4
----------------------------------------------------------------------------------------
Inspection
------------------------------------------------
ROUGH ELEC v.1
----------------------------------------------------------------------------------------
Inspection
------------------------------------------------
SOLAR FINAL** v.3
----------------------------------------------------------------------------------------
Inspection
-- - - - - - - - - - - - - - - - - - - - - - - - - - --
SOLAR FINAL** v.2
Inspection
------- - - - - ------------------------------ - - - - -
SOLAR FINAL** v.1
-
Inspection
Printed: 5/23/25 11:39 am Page 2 of 3
BUILDING PERMIT
Permit Type: Solar
Permit Number: BSOL2021-0201
Property Address: 81359 PEARY PL
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the buildinq official.
Printed: 5/23/25 11:39 am Page 3 of 3
VECTOR
E n G I n E E R S
VSE Project Number: U2398.0022.211
November 4, 2021
Southern California Energy Alternatives
45-350 San Luis Rey
Palm Desert, CA 92260
REFERENCE: Madison Club Residence: 81359 Peary Place, La Quinta, CA 92253
Solar Array Installation
To Whom It May Concern:
BSOL2021-0201
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
ogre 12/17/2021 7
12.35kW PV SYSTEM
Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to
determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on
the panel layout plan.
Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation.
Design Parameters
Code: California Building Code, 2019 Edition (2018 IBC)
Risk Category: II
Design wind speed, Vult: 110 mph (3-sec gust)
Wind exposure category: C
Seismic:
Importance factor, I: 1.00
Mapped spectral response accelerations: SS: 1.508g S 1: 0.702g
Site class: D
Spectral response coefficients: SDS: 1.005g SDI: 0.796g
Seismic design category: D
Connection to Roof
Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 72" o.c. along rails
(2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 67 in. Rail cantilever shall
not exceed 50% of connection spacing.
Conclusions
Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation.
In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5).
The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or
increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is
permitted to remain unaltered.
651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com
VSE Project Number: U2398.0022.211
Madison Club Residence
YE C TOR 11/4/2021
E n G I n E E R S
The solar array will be low -profile (no more than 10" above the roof surface). Thus, we conclude that any additional wind
loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the
capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding
seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall
materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 2.2%.
Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4
of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered.
Limitations
Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed
must be in accordance with accepted industry -wide methods and applicable safety standards. The contractor must notify
Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the as -built condition of the
structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except
at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by
others is allowed only where the building type, site conditions, site -specific design parameters, and solar panel configuration
match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering
is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural
Engineering assumes no responsibility for improper installation of the solar array.
VECTOR STRUCTURAL ENGINEERING, LLC
11/04/2021
Jacob Proctor, P.E.
CA License: 70567 - Expires: 06/30/2023
Project Engineer
Enclosures
JSP/nat
651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com
VECTOR
E n G I n E E R S
PROJECT: Madison Club Residence
CHECK INCREASE IN OVERALL SEISMIC LOADS
Estimated Roof Dead Load
10.0
Solar Dead Load
3.0
% Roof Covered
7%
Equiv. Total Dead Load
10.2
Addt'I Seismic Weight
2.2%
psf
psf
psf
JOB NO.: U2398.0022.211
SUBJECT: SEISMIC LOADS
Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an
increase in the total weight (and resulting seismic load) of 2.2%. Because the increase is less than 10%, this
addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing structure
is permitted to remain unaltered.
VECTOR
E n G I n E E R S
PROJECT: Madison Club Residence
Com onents and Cladding Wind Calculations
Label: ISolar Panel Array
SITE -SPECIFIC WIND PARAMETERS:
Basic Wind Speed [mph]: 110 Notes:
Exposure Category: C
Risk Category: II
ADDITIONAL INPUT & CALCULATIONS:
Height of Roof, h [ft]: 15 (Approximate)
Comp/Cladding Location: (GCrn)nom, 0°<=w<=5°
Enclosure Classification: Enclosed Buildings
Zone 1 (GCrn)nom: 0.70 Figure 29.4-7
Zone 2 (GCrn)nom: 0.93 (negative coeff.)
Zone 3 (GCrn)nom: 1.05
JOB NO.: U2398.0022.211
SUBJECT: WIND PRESSURE
Note: Calculations per ASCE 7-16
a:
9.5
Table 26.11-1
zg [ft]:
900
Table 26.11-1
Kh:
0.85
Table 26.10-1
Ke:
1.00
Table 26.9-1
KZt:
1
Equation 26.8-1
Kd:
0.85
Table 26.6-1
Velocity Pressure, qh [psf]:
22.4
Equation 26.10-1
YE:
1.50
Section 29.4.3
YC:
0.94
Section 29.4.4
yP:
1.20
Section 29.4.4
WIND PRESSURES:
Equation
29.4-5 p = qh (GCY71), (GC,,) _ (Yp)(Yc)(YE)(GCrn)nom
Zone 1, p [psf]:
26.4
psf (1.0 W)
Zone 2, p [psf]:
34.8
psf (1.0 W)
Zone 3, p [psf]:
39.6
psf (1.0 W)
(2h = 30 ft)
VECTOR
E M G in E E R S
PROJECT: Madison Club Residence
Calculate Uplift Forces on Connection
Zone 1
Zone 2
Zone 3
JOB NO.: U2398.0022.211
SUBJECT: CONNECTION
Pressure 1 Max Trib. Max Uplift
Width
(0.6 Dead -0.6 Wind) Max Trib. Area z Force
(psf) (ft) (ft) (Ibs)
14.1
6.0
16.8
235
19.1
6.0
16.8
320
21.9
6.0
16.8
367
Calculate Connection Capacity
Lag Screw Size [in]:
Cd:
Embedment3 [in]:
Grade:
Nominal Capacity [Ibs/in]:
Number of Screws:
Prying Coefficient:
Total Capacity [Ibs]:
Determine Result
Notes
5/16
1.6
2.5
DF (G = 0.5)
266
1
1.4
760
NDS Table 2.3.2
NDS Table 12.2A
Maximum Demand [lbs]:l 367
Lag Screw Capacity [Ibs]: 1 760
Result: Capacity > Demand, Connection is adequate.
1. 'Max Trib. Width' is the width along the rails tributary to the connection.
2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the
rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 67".
3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag
screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the
embedment length.
yTn G I n E E R
PROJECT: Madison Club Residence
GRAVITY LOADS
JOB NO.: U2398.0022.211
SUBJECT: GRAVITY LOADS
Roof Pitch: 1 0.2 :12
Design material
Increase due to
Material weight
ROOF DEAD LOAD (D)
weight [psq
pitch
[psq
Asphalt Shingles
2.0
1.00
2.0
1 /2" Plywood
1.0
1.00
1.0
Framing
3.0
3.0
Insulation
0.5
1.00
0.5
1/2" Gypsum Clg.
2.0
1.00
2.0
M, E & Misc
1.5
1.5
Total Existing Roof DL
10.0
PV Array DL
3.0
1.00
3
ROOF LIVE LOAD (Lr
Existing Design Roof Live Load [psf] 20 ASCE 7-16 Table 4.3-1
Roof Live Load With PV Array [psf] 0 2019 CBC, Section 1607.13.5
VECTOR
E M G I M E E R S
PROJECT: Madison Club Residence
Summary of Loads
D [psf]
Lr [psf]
S [psf]
Maximum Gravitv Loads:
JOB NO.: U2398.0022.211
SUBJECT: LOAD COMPARISON
Existinq With PV Arrav
10
13
20
0
0
0
Existing With PV Array
(D + Lr) / Cd [psf] 24 14 ASCE 7-16, Section 2.4.1
(D + S) / Cd [psf] 11 14 �ASCE 7-16, Section 2.4.1
(Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr)
Maximum Gravity Load [psf]:l 24 1 14
Ratio Proposed Loading to Current Loading: 1 60% OK
"he gravity loads, and thus the stresses of the structural elements, in the area of the
olar array are either decreased or increased by no more than 5%. Therefore, the
equirements of Section 503.3 of the 2019 CEBC are met and the structure is permitter
o remain unaltered.
VECTOR
E n G I n E E R S
VSE Project Number: U2398.0022.211
July 13, 2022
Southern California Energy Alternatives
45-350 San Luis Rey
Palm Desert, CA 92260
REFERENCE: Madison Club Residence: 81359 Peary Place, La Quinta, CA 92253
Solar Array Installation
To Whom It May Concern:
Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to
determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on
the panel layout plan.
Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation.
Design Parameters
Code: California Building Code, 2019 Edition (2018 IBC)
Risk Category: II
Design wind speed, Vult: 110 mph (3-sec gust)
Wind exposure category: C
Seismic:
Importance factor, L• 1.00
Mapped spectral response accelerations: SS: 1.508g S 1: 0.702g
Site class: D
Spectral response coefficients: SDS: 1.005g SDI: 0.796g
Seismic design category: D
Connection to Roof
Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 72" o.c. along rails
(2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 69.1 in. Rail cantilever shall
not exceed 50% of connection spacing.
Conclusions
Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation.
In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5).
The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or
increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is
permitted to remain unaltered.
651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com
VSE Project Number: U2398.0022.211
Madison Club Residence
T O R 7/13/2022
E n G I n E E R S
The solar array will be low -profile (no more than 10" above the roof surface). Thus, we conclude that any additional wind
loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the
capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding
seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall
materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 2%.
Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4
of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered.
Limitations
Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed
must be in accordance with accepted industry -wide methods and applicable safety standards. The contractor must notify
Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the as -built condition of the
structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except
at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by
others is allowed only where the building type, site conditions, site -specific design parameters, and solar panel configuration
match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering
is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural
Engineering assumes no responsibility for improper installation of the solar array.
VECTOR STRUCTURAL ENGINEERING, LLC
07/13/2022
Jacob Proctor, P.E.
CA License: 70567 - Expires: 06/30/2023
Project Engineer
Enclosures
JSP/nat
651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com
VECTOR
E n G I n E E R S
PROJECT: Madison Club Residence
CHECK INCREASE IN OVERALL SEISMIC LOADS
Estimated Roof Dead Load
10.0
Solar Dead Load
3.0
% Roof Covered
7%
Equiv. Total Dead Load
10.2
Addt'I Seismic Weight
2.0%
psf
psf
psf
JOB NO.: U2398.0022.211
SUBJECT: SEISMIC LOADS
Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an
increase in the total weight (and resulting seismic load) of 2%. Because the increase is less than 10%, this
addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing structure
is permitted to remain unaltered.
VECTOR
E n G I n E E R S
PROJECT: Madison Club Residence
Com onents and Cladding Wind Calculations
Label: ISolar Panel Array
SITE -SPECIFIC WIND PARAMETERS:
Basic Wind Speed [mph]: 110 Notes:
Exposure Category: C
Risk Category: II
ADDITIONAL INPUT & CALCULATIONS:
Height of Roof, h [ft]: 15 (Approximate)
Comp/Cladding Location: (GCrn)nom, 0°<=w<=5°
Enclosure Classification: Enclosed Buildings
Zone 1 (GCrn)nom: 0.70 Figure 29.4-7
Zone 2 (GCrn)nom: 0.92 (negative coeff.)
Zone 3 (GCrn)nom: 1.04
JOB NO.: U2398.0022.211
SUBJECT: WIND PRESSURE
Note: Calculations per ASCE 7-16
a:
9.5
Table 26.11-1
zg [ft]:
900
Table 26.11-1
Kh:
0.85
Table 26.10-1
Ke:
1.00
Table 26.9-1
KZt:
1
Equation 26.8-1
Kd:
0.85
Table 26.6-1
Velocity Pressure, qh [psf]:
22.4
Equation 26.10-1
YE:
1.50
Section 29.4.3
YC:
0.95
Section 29.4.4
yP:
1.20
Section 29.4.4
WIND PRESSURES:
Equation
29.4-5 p = qh (GCY71), (GC,,) _ (Yp)(Yc)(YE)(GCrn)nom
Zone 1, p [psf]:
26.5
psf (1.0 W)
Zone 2, p [psf]:
34.9
psf (1.0 W)
Zone 3, p [psf]:
39.7
psf (1.0 W)
(2h = 30 ft)
VECTOR
E M G in E E R S
PROJECT: Madison Club Residence
Calculate Uplift Forces on Connection
Zone 1
Zone 2
Zone 3
JOB NO.: U2398.0022.211
SUBJECT: CONNECTION
Pressure 1 Max Trib. Max Uplift
Width
(0.6 Dead -0.6 Wind) Max Trib. Area z Force
(psf) (ft) (ft) (Ibs)
14.1
6.0
17.3
244
19.1
6.0
17.3
331
22.0
6.0
17.3
380
Calculate Connection Capacity
Lag Screw Size [in]:
Cd:
Embedment3 [in]:
Grade:
Nominal Capacity [Ibs/in]:
Number of Screws:
Prying Coefficient:
Total Capacity [Ibs]:
Determine Result
Notes
5/16
1.6
2.5
DF (G = 0.5)
266
1
1.4
760
NDS Table 2.3.2
NDS Table 12.2A
Maximum Demand [lbs]:l 380
Lag Screw Capacity [Ibs]: 1 760
Result: Capacity > Demand, Connection is adequate.
1. 'Max Trib. Width' is the width along the rails tributary to the connection.
2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the
rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 69".
3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag
screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the
embedment length.
yTn G I n E E R
PROJECT: Madison Club Residence
GRAVITY LOADS
JOB NO.: U2398.0022.211
SUBJECT: GRAVITY LOADS
Roof Pitch: 1 0.2 :12
Design material
Increase due to
Material weight
ROOF DEAD LOAD (D)
weight [psq
pitch
[psq
Asphalt Shingles
2.0
1.00
2.0
1 /2" Plywood
1.0
1.00
1.0
Framing
3.0
3.0
Insulation
0.5
1.00
0.5
1/2" Gypsum Clg.
2.0
1.00
2.0
M, E & Misc
1.5
1.5
Total Existing Roof DL
10.0
PV Array DL
3.0
1.00
3
ROOF LIVE LOAD (Lr
Existing Design Roof Live Load [psf] 20 ASCE 7-16 Table 4.3-1
Roof Live Load With PV Array [psf] 0 2019 CBC, Section 1607.13.5
VECTOR
E M G I M E E R S
PROJECT: Madison Club Residence
Summary of Loads
D [psf]
Lr [psf]
S [psf]
Maximum Gravitv Loads:
JOB NO.: U2398.0022.211
SUBJECT: LOAD COMPARISON
Existinq With PV Arrav
10
13
20
0
0
0
Existing With PV Array
(D + Lr) / Cd [psf] 24 14 ASCE 7-16, Section 2.4.1
(D + S) / Cd [psf] 11 14 �ASCE 7-16, Section 2.4.1
(Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr)
Maximum Gravity Load [psf]:l 24 1 14
Ratio Proposed Loading to Current Loading: 1 60% OK
"he gravity loads, and thus the stresses of the structural elements, in the area of the
olar array are either decreased or increased by no more than 5%. Therefore, the
equirements of Section 503.3 of the 2019 CEBC are met and the structure is permitter
o remain unaltered.
RR�W-11q -LAq0 -0 33
No. of DC and AC DC and
modules. DC and AC rating Inverter watts of AC kW of
inverters of module efficiency STC calculation system system
REC SOLAR 33 325 12041.25 watts 12,350 watts -DC 12.4 kW -DC
REC325TP3M-BLK 304 97.r5';: 11,020 watts -AC 11.0 kW -AC
Inverter nameplate Inverter efficiency
Enphase Energy 3 , 290 97.0% 240vac
IQ7PLUS-60-2-US
Note: total watts -AC of system cannot exceed the total nameplate watt rating of the inverters
TOTAL DC WATTS
TOTAL AC WATTS
12041.25 watts 12.350 watts -DC 12.4 kW -DC
11,020 watts -AC 11.0 kW -AC
Ap,�#�--I -lq-490-U33
WEIGHT LOADING ANALYSIS
Solar Electric Installation
MADISON CLUB -LOT 59A Residence _81359 PEARY PLACE. LA QUINTA,CA 92253
Contractor_ Southern California Energy Alternatives October 27, 2021
Analysis of dead load weight added by installation of solar arra
REC SOLAR-#REC325TP3:L1-BLK-solar module weight
No, of solar modules
Total weight of modules
Weight of each Professional Solar Products "Roof Trac" rack set
No. of rack sets
Total weight of rack sets
Total weight of solar array
Heicht of each module
Width of each module
Area of one module
Area of entire solar array
Weight of solar array per un;t
No. of stanchions connected to rafters with lag screws
Weight loading per vertical pipe
40.78
pounds
pounds
pounds
pounds
pounds
feet
feet
square feet
square feet
pounds/square foot
pounds/connection
38
1.550
40
9.5
377
1,927
5.6
3.3
18.6
706.4
2.7
45
42.8
See attached sheets for engineering information on the Professioal Solar Products 'Roof-Trac" racks
All MCI & ASSOCIATES
Structural Engineers
CLIENT:
Professional Solar Products, Inc.
1551 S. Rose Ave., Oxnard, CA 93033
Tel: 805-486-4700
Subject: Static load test results for the following:
Mounting System
Maximum Frame
Maximum Frame
Load
Equivalent Wind Speed
Length` (in.)
Width' (in.)
(lbs/ft2)
(mph)"
RoofTrac
65 (77")
40
50
125 (100"')
ILSTSEfUP (as shown in attached drawingdetail): Three modules, as specified above, were bolted to 136-'x1.5'x2.5'
Professional Solar Products (PSP) patented Rcof7ra0 support rails using an assembly of 5/16' Stainless Steel (SS) bolts,
SS look washers and proprietary PSP aluminum clamps and inserts. The RoofTrac'F, support rail was attached to the PSP
RoofTracO structural attachment device with 3/8' SS hardware at four attachment points. The setup was attached to 2 "x6"
wooden rafters using 5/16" x 3-1/2" SS lag bolts. The attachment spans consisted of 48" front to rear with structural
attachments spaced 72" on center.
TEBT PROCEDURE (as shown in attached drawing detaiq: The test set up was top loaded to 50 Ib/ft2. The setup remained
loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were
recorded. The test setup was then inverted and loaded to simulate the uplift condition. The test set up was re -loaded to 50
Ib/ft The setup remained loaded for an approximate period of 30 minutes. The maximum deflect.on and any signs of
permanent deformation were recorded.
TEST RESULTS:
The maximum top load deflection was recorded at 0.313", with no permanent deformation,
The maximum uplift deflection was recorded at 0.250 with no permanent deformation.
This document certifies the RocffracS mounting system used with the modules, as specified above, withstands the stated
static pressure load, equivalent to the stated wind speeds**. The mounting system performed as expected.
Sincerely,
James R. Vinci, S.E.
This engineering report verifies that \i nci & Associates has provided independent observation for load testing as described in this report. The results of this
load test reflect actual deflection values and are generally accepted as the industry standard for testing module mounting systems. Vinci & Associates does
not field check installations or verity that the mounting system is installed as described in this engineering report.
Structural attachment: Lag bolt attachment should be installed using the proper pilot hole for optimum strength. A 5/16- lag bolt requires a 3/
It is the responsibility of the installer to insult a proper attachment is made to the structural member of the roof. Failure to securely attach to t
structure may result in damage to equipment. personal injury or property damage. The purposed racking system may be installed on any roof
maximum of 24 foot above grade without further analysis. Racking can be installed at any location on the roof. Racking shall be installed in 6
or blocking with a 5/16' diameter screw at each Fast -jack location. Screws shall have minimum of 2 rh penetration into fram ing member fc zc
minimum of 3" penetration into framing member for zone 3. (Zone 3 is defined as the approximately 4'-0' square at each corner of the rcgf)
This office does not express an opinion as to the load bearing characteristics of the structure the
mounting system/modules are being installed on.
ICC accredited laboratory tested structural attachments manufactured by Professional solar Products
(including, but not limited to FasUack3 . TileTracI'. and FoamJaW) can be interchanged with this
system.
Check with local building department or AHJ for site specific requirements.
-Modules measuring within stated specifications and tested to UL1703. or equivalent. are included
in this engineering
* *wind loading values relative to defined load values using wind load exposure (125 mph for 5/12
roof pitch or less; 100 mph for greater than 5/ 12 roof pitch) and gust factor coefficient 'exposure C-
as defined in the 2012(IBC) /2013(CBC). For 7 7' x 40" module. equivalent wind speed aerated to
100 mph.
* * *Module tested: 64.6' x 39.4" x 1.7' (sin)
<**"Est. snow load rating of 25 Ib/ft2 based on 2.0 safety factor, (15 Ib/ft-' for 77' x 40' module)
1337 E. Thousand Oaks Blvd, Ste 114
Thousand Oaks, CA
moer
and a
Page 1 of 2 RT 6
Module
Area =
18 ft` each
72" I
AFFroz max Is_
overharg II�
Total module (45 lbs ea.)
and rail (12 Ibs ea.) weight:
159
Ibs
Number of attachments:
4
ea
Weight / attachment point:
40
Ibs
Area:
54
ft2
Distributed weight:
2.95
Ib/ ft2
5116" Stainless
Steel Hex bolt
G R E a , I A
�- - LI J
Top Load Deflection: 0.313"
2,710 lb�'
50 psf
5/16" Stainless Steei
Lock Washer
' I cowcae4e B��i..PT l l�
Aluminum ProSolar
Inter -Module Clamp
Aluminum ProSolar Up lift Deflection: 0,250" /] i
Rail rut
2-1/2' Aluminum ProSolar
RoofTracT) Support Rail
3/8" Stainless Steel Hex
Bolt and Flat VVasher
Aluminum ProSolar patentedS �y
FastJackC Roof Attachment*
0 No.' ' 1
p. 2/ 1 jtd
5/16" Stainless Steel Lag Bolt
and Flat Washer
'Lab tested structural attachments manufactured by Professional Solar Products
iincluding FastlackD . TileTrac-T. and FoamlocKT) car. be interchanged with this system.
Professroral Solar Products P.cofTracc P8tert:: 6 360.49'
Photovoltaic mounting system
RoofTrac`
Solar Modules
Static load test illustration
Page 2 of 2
RT 6
General Protect Description:
BSOL2021-0201
12.35kW SOLAR ARRAY - (38)
325W REC SOLAR
REC325TP3M BLACK PANELS
W/ (38) ENPHASE
IQ7PLUS-72-2-US
MICROINVERTERS + 125A IQ
1. System is 12,350 W - STC COMBINER 3 BOX [760SF]
2. Modules: 38 @ REC325TP3M Black, 325 Watt Panels 2019 CALIFORNIA BUILDING
3. Inverters: 38 @ Enphase IQ7PLUS-72-2-US microinverters CODES.
4. No Batteries or UPS CITY OF LA QUINTA
5. This is a tilt mounted system adding 2.8 Ib/sq BUILDING DIVISION
6. Modified bitumen on flat roof REVIEWED FOR
CODE
7. 1 - story house COMPLIANCE
8. 2 x 4 rafters @ 24" OC with 5/8" OSB sheathing IDATr06/30/2022 3Y
9. ProSolar Solar Wedge 5° Kit 72" OC with 3/8" x 6" Lag Bolts
10. Standard components include: Prosolar racking and mounting components, wiring, conduit, over -current
protection, roofing sealant, flashings, as needed
11. All electrical equipment will be labeled with warning labels (see page 5)
12. All outdoor wiring will be weather rated
13. All module frames, equipment and conductor enclosures will be grounded
14. The system is grounded using the Prosolar Grounding System
15.This system has been calculated to meet the basic wind speed of 110 MPH and wind exposure C
16.All construction shall comply with the 2019 California Building, Residential, Mechanical, Electrical, Plumbing,
Energy and Green Building Codes and the La Quinta Municipal Code
17.The installation of equipment and all associated wiring and interconnections shall be performed only by
qualified persons (CEC §690.4(C))
18.Automatic Rapid Shutdown (upon AC Grid Disconnect) integrated in Enphase inverters
19.PV source circuits and PV output circuits shall not be contained in the same raceway, cable tray, cable outlet
box, junction box, or similar fittings as conductors, feeders, branch circuits of other non-PV systems, or
inverter output circuits unless the conductor of the different systems are separated by a partition. PV system
circuit conductors shall be identified and grouped as required by 690.31(13)(1) through (4). The means of
identification shall be permitted by separate color coding, marking tape, tagging, or other approved means
(CEC §690.31(13))
CONSTRUCTION HOURS
October 1st- April 30
Monday - Friday: 7 00 a m to 5:30 p.m
Saturday 8:00 a.m to 5:00 p.m
Sunday None
Govemment Code Holidays None
May 1 st - September 30th
Monday - Friday. 6 00 a.m to 7:00 p.m.
Saturday 8.00 a.m. to 5.00 p.m.
Sunday :None
Government Code Holidays. None
Construction is NOT PERMITTED
in the following Code Holidays:
New Year's Day
Dr. Martin Luther King Jr, Day
President's Day
Memorial Day
Independence Day
Labor Day
Veteran's Day
Thanksgiving Day
Christmas
"AN ADEQUATELY SIZED DEBRIS
CONTAINER IS REQUIRED ON THE
ALL CONSTRUCTION SHALL COMPLY WITH
JOB SITE DURING ALL PHASES OF
THE 2019 CALIFORNIA RESIDENTIAL,
CONSTRUCTION AND MUST BE
EMPTIED AS NECESSARY. FAILURE
MECHANICAL, ELECTRICAL, PLUMBING,
TO DO SO MAY CAUSE THE CITY
TO HAVE THE CONTAINER DUMPED
GREEN BUILDING AND ENERGY CODES
AT THE SE OF THE OWNER/
CONTRACTOR
AND THE LA QUINTA MUNICIPAL CODE
Vector Structural Engineering has reviewed the existing
structure with loading from the solar array and screw
connections to the existing framing. The design of the
racking system, racking connections, and all other
structural is by others. Mechanical, architectural, and all
other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
Approvals Date
Drawn 10 15 2021
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings. specifications or other contract documents. The Owner or General Contractor shall notify the Designer. in writing.
of such error or omission. In the event that the Owner or General Contractor falls to give such notice. before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
rrrr
rrrr
rrrr
rrrrrr
rrrrrr
rrrrrr
rrrrrr
rrrr rr
rr
Approved by:
.. Brandon
� VECTOR
E n O 1 n E E R 8
651 W. GALENA PARK BLVD. STE. 701 PHONE (807) 990-7 775
DRAPER, UTAH B4020 - WWW.VECTORSE.COM
CO
0
W'
'sl clv►� ��P
11 /04/2021
VSE Project Number: U2398.0022.211
Slater (760) 895-9474
I - Project Description I
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer.- I Madison Club
Lot 59A
Drawing Number:) REV: #
t. 21-038
81359 Peary Place
La Quinta, CA. 92253
Lc tr -i-1Q-4Qn _n�:
Scale: I Sheet 1 of 5
f 1350LZ 02) 0201
�h,nl,Wn Ifa'
i IPFFIGHILP 1 I I I I I I EMTCandoltun Rood
sCCE SS PORIT / l 2-Mln aow It-w,
EnpMwlO LanMarlBl
lacMW on Rod
Al Dnco—..INI
DISCLAIMr/l II any Enms, Dlscropancres or Ommarans appear In In— drawings, Specifications or other contract dxumente, The Owner a G-111 Can11a1.Ya1 shall nobly the D-Ignon, n writing,
of Such error or omtsmn In the event that the Owner or General Contraclor falls to give such notice. before Conslruchon anWor labncation of the work, the Owner or General Contractor will be
hold responsible to the result at any finals. dbarapa 10% or onlJflons one the cost of readpng them
Legend.
(E) Existing
(N) New
PL Property Line
❑ Skylight
vent
® Chimney
CITY OF LA QUINTA
BUILDING DrVISION
REVIEWED FOR
CODE
COMPLIANCE
osrl 12/17/2021 l-
3-1 —y - Rool Mount INI
39 p REC3251P3M Black P-1, ad,
33
p alp
1pLUS-72 2-US maonvsrlsls
123e0 SW:
I1 210 sW - Ac Inv.d,r bulgur
Approvals Date
�I
pproved by-
randon Slater (760) 895-9474
Site Plan
45-350 San Luis Rey
Contractor:
Southern California
Palm Desen, CA 92260
Energy Alternatives
760-904-4917
CSLB # 988895
Madison Club
81359 Peary Place
Customer:
Lot 59A
La Quinta, CA, 92253
,awing Number
2,-038
REV: #
Scale: 1/16" = 1'
Sheet 2 of 5
(N) Solar Array
38 @ REC325TP3M Black panels
66.25" x 39.25" x 1.5"
1'-6"
25'
Roof Section Scale 3/811 = 1'
(E) 2 x 4 Rafters @ 24" OC with 5/8., OSB Sheathing
and Modified Bitumen Roofing Material
Roof Pitch: 1 °
2 x 4 Rafters @ 24" OC
Legend:
(E) Existing
(N) New
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
Dntr 12/17/2021 e _
Approvals Date
Drawn t0152027
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
FESSIp q �YECTOR
S-PR
V �
m 657 W. GALENA PARK 5LV0, STE, 707 PHONE (SO7) 990-7775
w- DRAPER, UTAH B402O WWW. VECTOR5E.COM
Cr 11 /04/2021
VSE Project Number: U2398.0022.211
sl CIVN. ��\P actor Structural Engineering has reviewed the existing structure with loading from the solar array and
4"4t0FA1��0 ;rew connections to the existing framing. The design of the racking system, racking connections, and all
C her structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are
i others. Electrical is by others, unless stamped by Dean Levorsen.
(N) ProSolar Residential Rail,
S
anodized aluminum 1.5" x 1.5"
(N) ProSolar Solar Wedge 5° Kit
72" OC with 3/8" x 6" Lag Bolts
(E) 2 x 4 Rafters 24" OC
Attachment Detail Scale 1" = 1'
Approved by:
Brandon Slater (760) 895-9474
- Attachment
Detail
45-350 San Luis Rey
Contractor:
Southern California
Palm Desert, CA 92260
Energy Alternatives
760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A La Q iinta, CA 92253 3
awing Number: REV: # Scale: Sheet 3 of 5
21-038
f 6SOL2_021-020 I
PV Array (N)
3 Branch Circuits of 12 and 2 x 13 Modules in Parallel on Roof
(38) REC325TP3M Black Panels
(38) Enphase IQ7PLUS-72-2-US Microinveners under panels
Output: 12.350 Watts STC
SUM OF INVERTER OUTPUT:
1.21 Amp x 38 x 125% = 57.475 Amp
Legend:
(E) Existing
(N) New
Single Line Notes:
Junction Boxes (N)
Weather proof Bell box
J-BOX
Enphase IQ Combiner (N)
X-10-AM1-240-B
240 V
AC Disconnect (N)
2P60A - Non -Fused
240 V
NEMA 3R
Located next to
Main Electrical Panel
Main Service Panel (I
600 Amp Main Service
Bussbai Rated L 600 Amps
1—..N (9) 125% = 18.15 A (1.21 A x 12 x 125%)
12) 0 12 THWN-2 - in Enphase O Cable
Equipment Grounding Conductor
(1)"
6 solid copper (6) # 8 THWN-2
Wire tun under panels through inveners (1) 0 8 THWN-2 (AC-EGC)
(2) # 6 THHN/THWN-2
I. ,,w w 125%. = 19.6625 A (1.21 A x 13 x 125%) 3/4" EMT Conduit on Roof (1) # 6 THH WTHWN-2 AC EGC
(2) # 12 THWN-2 - in Enphase Q Cable Wire Sizing: 1" EMT Conduit
Equipment Grounding Conductor # 8 THWN-2 - 55A Wire Sizing
(1) 9 6 solid copper 55A x 80% (conduit fill) x 0.58 (temp. correction) = 25 52 A # 6 THWN-2 - 75A
Wire run under panels through Inverters 75A x 100% (conduit fill) x 0 82 (lemp. correction) = 61 5A
CITY OF LA QUINTA AUTOMATIC RAPID SHUTDOWN UPON AC GRID
BUILDING DIVISION DISCONNECT INTEGRATED IN ENPHASE INVERTERS
REVIEWED FOR CODE TO MEET NEC 2017
COMPLIANCE
—.1211712021 it, t L
1.
The DC circuit meets the requirements of ungrounded PV arrays in NEC 690.35.No additional GEC is
required. Ground Fault Protection is integrated into the inverter.
2.
All wire sizes are as indicated or larger.
3.
Wire sizes meet the criteria of 125% continuous use factor.
4.
All equipment is bonded by mechanical means or by a grounding conductor.
5.
All modules are grounded mechanically using Prosolar Grounding System,
Approvals
Date
6.
The system is grounded at the neutral buss in the main electrical panel.
7.
The system is grid - inteflie only, has no batteries or UPS.
8.
Individual panels inverted from DC to AC with microinverters located under panels.
9.
The Enphase Q Cable System (double insulated DG cable) does not have neutral wire
pproved by.
randon Slater (760) 895-9474
1 - Line
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
DISCLAIMER II any Errors. Discrepancies or Omissions appear in these drawings, specifications or older cWtiact documents; The OWne or General Contractor shall notify the Designer, m wrilugl Customer
of such eror or omission. In the event that the Ownei or General Contractor falls 10 give such notice. before construction and/or lad,cation of the wetk, the Owner or General Contractor Will be
held iespm.,ible to the result of any euors, rliscrepancKs or omissions and lute cost of iecblymg triem. Dtawino Numbi
Madison Club I 81359 Peary Place
Lot 59A La Quinta, CA, 92253
REV # I Scale: I Sheet 4 of 5
NEC 690.64(B)(7)
PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION
EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE))
THIS LABEL IS ONLY NECESSARY WHEN BREAKERS FEEDING
PANEL EXCEEDS 100% OF BUSS RATING
MAIN SERVICE PANEL
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT
DOWN PV SYSTEM AND
REDUCE SHOCK HAZARD
IN THE ARRAY
EXTERIOR / INTERIOR CONDUIT
NEC 690.54
PLACE THIS LABEL AT "INTERACTIVE POINT OF
INTERCONNECTION" (AT MAIN SERVICE PANEL AND
SUBPANEL IF APPLICABLE)
SOLAR ONLY SUBPANEL 12 PANEL CIRCUITS:
SOLAR ONLY SUBPANEL 13 PANEL CIRCUITS:
MAIN SERVICE PANEL:
NEC 690.56(B)
BUILDINGS OR STRUCTURES WITH BOTH UTILITY SERVICE
AND PHOTOVOLTAIC SYSTEM SHALL HAVE A PERMANENT
PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
SERVICE DISCONNECTING MEANS AND THE PV SYSTEM
DISCONNECTING MEANS IF NOT LOCATED AT THE SAME
n(,ATIC)N
AC DISCONNECT - READILY ACCESSIBLE:
Approvals
Date
Dra-,n
10 15 2021
Approved by:
CITY OF LA QUINTA BUILDING DIVISION randon Slater (760) 895-9474
REVIEWED FOR
CODE I �+
COMPLIANCE Label J
arc12/17/2021 �
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
Customer: I Madison Club I 81359 Peary Place
Lot 59A La Quinta., CA,_9225
Drawing Number:I REV: # I Scale: I Sheet 5 of 5
L 21-038
SOL20Z I - OZO I
General Project Description:
REVISION 1
BSOL2021-0201
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
1. System Is 12,350 W - STC o�,E07/11/2022
2. Modules: 38 @ REC325TP3M Black, 325 Watt Panels
3. Inverters:38 @ Enphase IQ7PLUS-72-2-US microinverters REVISED ROOF LAYOUT
4. No Batteries or UPS
5. This is a tilt mounted system adding 2.81b1sq AND UPDATED
6. Modified bitumen on flat roof CONDUCTOR SIZES
7. 1 - story house
8. 2 x 4 rafters @ 24" OC with 5/8" OSB sheathing
9. ProSolar Solar Wedge 5` Kit 72" OC with 3/8" x 6" Lag Bolts
10. Standard components include: Prosolar racking and mounting components, wiring, conduit, over -current
protection, roofing sealant, flashings, as needed
11. All electrical equipment will be labeled with warning labels (see page 5)
12. All outdoor wiring will be weather rated
13. All module frames, equipment and conductor enclosures will be grounded
14. The system is grounded using the Prosolar Grounding System
15.This system has been calculated to meet the basic wind speed of 110 MPH and wind exposure C
16.AII construction shall comply with the 2019 California Building, Residential, Mechanical, Electrical, Plumbing,
Energy and Green Building Codes and the La Quinta Municipal Code
17.The installation of equipment and all associated wiring and interconnections shall be performed only by
qualified persons (CEC §690.4(C))
18.Automatic Rapid Shutdown (upon AC Grid Disconnect) integrated in Enphase inverters
19.PV source circuits and PV output circuits shall not be contained in the same raceway, cable tray, cable outlet
box, junction box, or similar fittings as conductors, feeders, branch circuits of other non-PV systems, or
inverter output circuits unless the conductor of the different systems are separated by a partition. PV system
circuit conductors shall be identified and grouped as required by 690.31(B)(1) through (4). The means of
identification shall be permitted by separate color coding, marking tape, tagging, or other approved means
(CEC §690.31(B))
VECTOR
07/05/2022
VSG Proicct Number, U2398.0022.211
VMd 9m.«Yr kro„.r,ro n...M+wl II..nN.yi
YWvn rF Iwa.,y „ern M sdr rr.r r,a w.w
,rkv,i sYM.m'rncW car„r,.Lann .M Y oIM,
Wr a M dtin N.uuMul r r,u M
u«nu r w w,.....rvu ur.,o.0 ur onr, to+ww,�
Approved by:
Brandon Slater (760) 895-9474
Approvals Date Project Description
o.wn ,N11TOJ,
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
DISCLAIMER If any Errors. D,scrop—es or Ov ,VP-. In.- drawags. spoc,h-wn, or off., contract documents. The Owner w General Conlructor shall notify the Dosgnor, ,n wntmq.
o1 such enor or om, s In the oven) that the Owner or Gonaral Conlr or laps to g,ve iuch notice. before conitrumon andlor labrlcabon of the work, the Owner or General Contractor wJl be
field renponslde to rtre result of any arron, d—al ancas or onuss,ons and the cos, of rechfyinp then,
Customer Madison Club 81359 Peary Place
Lot 59A La Quinta, CA, 92253
awing Number REV: 0
21-038 Scale: Sheet 1 of 5
4- MO L 2-0 z I -
0
61
07/05/2022 0 lereel e
VSE Projcci Nmnlxr. U239ft 0022 211 tiny ne
Vegv sluur Envrwrry M1e• eree. Iti ..trey
•YrcYe e•er 1•'eOry 4em Iti r,l•r ver N rrew
mwclgn• b e. e..sy e.rry h. ne.y� a ev
re.Aey •wwn. r«Aey ru.eu.,,,e .ro a on,.r
••,r✓r n q ar,en. w«n.r,nel, ruwleuurr..q r
«wr ewnu a n. ae.yn .,. W wr.
kr««ul n W u1Mr• urY•• •W Vwl UY lueri Lewevn
LIRErIGHTI
ACCr SS Pc
k
DISCLAIMER 11 any Errors. Discrepancies or Omissions appear in those drawing%, spoafr itions or other mnlrml documents. The Chmor or General Contractor shall notify the Devpnor, m wrdmq,
or such error or omission. In the event that the Owner or General Coc raclof farls to give such nonce, before conslruchon and/or fabrication of the work, the Owner or General Contractor wait no
held responsible to the result of any errors. discrepancies or omissions and the cost of rWitying them.
REVISION 1
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
oAn 07/11 /2022 , ____r_
$d.,r bray - Root Mount (N)
39 Q REC32SIPlM Z. Pb,M•.11,
35V 107PEUS72.2-US m1-ortr,
12.350 kW . DC
11 210 kW . AC Invent output
Legend:
(E) Existing
(N) New
PL Property Line
❑ Skylighl
Vent
® Chimney
Approvals Date
u,,.o talv2un
Approved by:
Brandon Slater (760) 895-9474
Site Plan
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB tf 988895
Customer: Madison Club 81359 Peary Place
Lot 59A La Quinta, CA, 92253
rawtng Number REV0 Scale. 1/16" = 1' 1 Sheet 2 of 5
91_MA
OLZ02-1-OZOI
(N) Solar Array
38 @ REC325TP3M Black panels
66.25" x 39.25" x 1.5"
Roof Section Scale 3/8" = 1'
(E) 2 x 4 Rafters @ 24" OC with 518" OSB Sheathing
and Modified Bitumen Roofing Material
Roof Pitch: 1 °
Legend:
(E) Existing
(N) New
DISCI. AIMFR 11 any Enors. Discrop.r,—s or Omcsions appear in These drawings, specrbaitions or other contract dooumonts, The Owner or General Contractor shall notify the Designer. in wntno,
of such —or or orn—on In the o 1 that the Owner w C rwral C-1—lor laps to grv. such rwlrce, t fwo construction and/or fabrication of the work, llw Owrwr or Gen—f Con"Mr mll be
hold responsible to the restil of any errors, discrepancies or omissions and the cost of roctilying them.
*ECTOR
VSGrProjcet Nunihcc U2398.o02. 211 Y
riVINT wnlr in.Y..�
1.n.rlban. ft TM
.M w..
.,«vm• io rro n.nnn M
Leo •ru.rn ..tuna mm«um•..m r miw
er.mrr �. er gym...•, w..• u. nn.o r,r a.«, r r....�,..�
07/05/2022
(N) ProSolar Residential Rail,
anodized aluminum 1.5" if 1.5"
(N) ProSolar Solar Wedge 5' Kit
72' OC with 3/8" x 6" Lag Botts
(E) 2 x 4 Rafters 24" OC
Attachment Detail Scale 1" = 1'
Approved by.
randon Slater (760) 895-9474
Attachment Detail
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB 4 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
REV: a I Scale: 1 Sheet 3 of 5
0SOL2A21- ON I
PV Array (N)
3 Branch Circuits of 12 and 2 x 13 Modules in Parallel on Roof
(38) REC3251P3M Black Panels
(38) Enphase 107PLUS-72-2-US Microinverters under panels
Output: 12,350 Watts STC
SUM OF INVERTER OUTPUT:
1.21 Amp x 38 x 125% = 57.475 Amp
Legend:
(E) Existing
(N) New
Sinale Line Notes:
2.
3.
4,
S.
Approvals Date 6.
7.
8.
9.
Junction Boxes (N)
Weather proof Bell box
1151.10 7
Im..u.q @ 125% = 18.15 A (1.21 A x 12 x 125%)
12),1 12 THWN-2 - in Enphase Q Cable
Equipment , our" ri Conduclor
(1) # 6 solid copper
Wire run under panels through inverters
I—..- @ 125% = 19.6625 A (1.21 A x 13 x 125%)
(2) # 12 THWN-2 - in Enphaso 0 Cable
Equipment Grounding Conductor Grounding Conductor:
(1) # 6 solid copper
Wire run under panels through Inverters
REVISION 1
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
,,rr07/11/2022 p
Enphase IQ Combiner (N)
x-I0-Arv11-240-B
240 V
INI) � itlar Ona�an
nvamx
AC Disconnect (N)
2P60A - Non -Fused
240 V
NEMA 3R
Located next to
Main Electrical Panel
(6) # 10 THWN-2 I
(1) # 8 THWN-2 (AC-EGC) L
314" EMT Conduit on Roof
Wire Sizing�
If 10 THWN-2 - 40A
40A x 80% (conduit fill) x 0.65 (temp. correction) = 20.8 A
Conduit is more than 3.5 above roof surface
Main Service Panel (E
600 Amp Main Service
Bussbar Rated @ 600 Amps
4.vi• N,r•
WIr Map
O
12. ,;,
iN)$NaN.Nr,
(2) # 6 THHNtTHWN-2
(1)# 6THHNlTHWN-2AC-LGC
1- EMT Conduit
Wire Sizing
# 6 THWN-2 - 75A
75A x 1 DO% (conduit fill) x 0 82 (lomp. corrraaion) = 61. SA
AUTOMATIC RAPID SHUTDOWN UPON AC GRID
DISCONNECT INTEGRATED IN ENPHASE INVERTERS
TO MEET NEC 2017
The DC circuit meets the requirements of ungrounded PV arrays in NEC 690.35.No additional GEC is
required. Ground Fault Protection is integrated into the inverter. ELECTRICAL ONLY
All wire sizes are as indicated or larger.
Wire sizes meet the criteria of 125% continuous use factor. ovµOFFS, o
All equipment is bonded by mechanical means or by a grounding Conductor. ,Q` gyp' LE Voj q�F
All modules are grounded mechanically using Prosolar Grounding System.
The system is grounded at the neutral buss in the main electrical panel. at o E 12178or
The system is grid - interne only, has no batteries or UPS. 011: o
Individual panels inverted from DC to AC with microinveners located under panels. s���F<EcrniGp� r
The Enphase Q Cable System (double insulated DG cable) does not have neutral wire
VSC- Project Nundur t12198.0022.21 1
DISCLAIMER If any Enors. Discrepancies or Omissions appear In these drawings, specifications or other contract documents: The Owner or General Contractor shall notify the Designer, in writing,
or sur'n error or omission. In the event that Ilia Owner w Gonmai contractor falls to give such notice. before construction andrnr fabrication of trio wotk, tho Owner or Gonoml Contracfor will bo
held responsible to the result of any errors, discrepancies or omissions and Ine cost of rectifying them.
Approved by. '
eandon Slater (760) 895-9474
1 - Line
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: EnergyAlternatives
760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A La Quinta. CA, 92253
awing Number REV. a Scale: Sheet 4 of 5
e, _noc
tbSOLZO-0101
NEC 690.64(B)(7) NEC 690.54 NEC 690.56(B)
PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION PLACE THIS LABEL AT "INTERACTIVE POINT OF BUILDINGS OR STRUCTURES WITH BOTH UTILITY SERVICE
EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) INTERCONNECTION" (AT MAIN SERVICE PANEL AND AND PHOTOVOLTAIC SYSTEM SHALL HAVE A PERMANENT
THIS LABEL IS ONLY NECESSARY WHEN BREAKERS FEEDING SUBPANEL IF APPLICABLE) PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
PANEL EXCEEDS 100% OF BUSS RATING SERVICE DISCONNECTING MEANS AND THE PV SYSTEM
DISCONNECTING MEANS IF NOT LOCATED AT THE SAME
LOCATION.
MAIN SERVICE PANEL
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT
DOWN PV SYSTEM AND
REDUCE SHOCK HAZARD
IN THE ARRAY
EXTERIOR / INTERIOR CONDUIT
SOLAR ONLY SUBPANEL 12 PANEL CIRCUITS:
SOLAR ONLY SUBPANEL 13 PANEL CIRCUITS:
MAIN SERVICE PANEL:
��YECTOR
n • in ■ ■ s
ELECTRICAL ONLY
oq%koF F S.g/o
9.IEJ/ %
WQ E12178 Zi
+n
��97��FCTAICP�. sa�r
tf 0't
07/05/2022
VSF Project Number U2398 0011,211
DISCLAIMER. It any Errors, Discrepancies or Omissions appear in these drawing-,. specifications or other contract documents. The Owner or General Contractor shall notify the Designer, In writing.
of such error or emission. In the even) that the Owner or General Contractor tolls to give such notice, before construction ancVor fabnwUon of the work, the Owner or General Contractor will be
held responsrWe to the result of any errors, discrepancies or omissions and the cost of roctdymg them.
AC DISCONNECT - READILY ACCESSIBLE:
Brandroved by:
on
Slater (760) 895-9474
Labels
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB b 988895
Customer: Madison Club 81359 Peary Place
Lot 59A La Quinta, CA, 92253
)raw23t8,g0bcr REVS a Scale: Sheet 5 of 5
4-BS0L20Z[-0H I
PLACARD FOR MAIN SERVICE PANEL:
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN
NW
go' NNW
.rYl PIAM r�/{r
U O1M1rA. CA OIYi]
*ECTOR
n• t n■ a w e
ELECTRICAL ONLY
OV" i FS.SlO
w� E12178 Zm
1Fo
07/05/2022
VSH Project Number: U2399.0022.211
DISCLAIMER It any Errors. Discrepancies or Omissions appear in these drawings, specifications mother contract documents: The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction andror fabrication of the work, the Owner m General Contractor will be
held responsible to the result of any errors. discrepancies or omissions and the cost of rectifying them.
REVISION 1
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
-)AtE07/11/2022 By 3:-
Approved by:
"randon Slater (760) 895-9474
PLACARD
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A La Quinta, CA, 92253
)rawing Number REVS #
,1_�,Q Scale Sheet 1 of 1
General Project Description:
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
'ECTOR
E n a I n E E R s
557 W. GALENA PARK OLVD, STE. 707 PHONE (807) 990-7775
DRAPER, UTAH 84020 - WWW.VE-SE.-
1. System is 13,870 W - STC I 07/14/2022 ,.� C �, o�S.PR �'`F/
y � �` � -I
2. Modules: 38 @ REC365TP4 Black, 365 Watt Panels C m
3. Inverters: 38 @ Enphase IQ7PLUS-72-2-US microinverters C 5 �
4. No Batteries or UPS
5. This is a tilt mounted system adding 2.8 Ib/sq s civl�-
6. Modified bitumen on flat roof T9TFOFCA��F°��
7. 1 - story house
8. 2 x 4 rafters @ 24" OC with 5/8" OSB sheathing 9. 07/13/2022
ProSolar Solar Wedge 5° Kit 72" OC with 3/8" x 6" Lag Bolts VSE Project Number: U2398.0022.211
10. Standard components include: Prosolar racking and mounting components, wiring, conduit, over -current
protection roofingsealant flashin s as needed VectorStructuralingifromt the has ewed
and he
protection, � g � structure with loading from the solar array and screw
11.All electrical equipment will be labeled with warning labels (see page 5) connectionsto
sy
stethe m,
gconnectio conThe nections,gn of and
e
racking system, racking connections, and all other
structural is by others. Mechanical, architectural, and all
12. All outdoor wiring will be weather rated other nonstructural aspects of the design are by others.
13.All module frames, equipment and conductor enclosures will be grounded Electrical is by others, unless stamped by Dean Levorsen.
14. The system is grounded using the Prosolar Grounding System
15.This system has been calculated to meet the basic wind speed of 110 MPH and wind exposure C
16.All construction shall comply with the 2019 California Building, Residential, Mechanical, Electrical, Plumbing,
Energy and Green Building Codes and the La Quinta Municipal Code
17.The installation of equipment and all associated wiring and interconnections shall be performed only by
qualified persons (CEC §690.4(C))
18.Automatic Rapid Shutdown (upon AC Grid Disconnect) integrated in Enphase inverters
19.PV source circuits and PV output circuits shall not be contained in the same raceway, cable tray, cable outlet
box, junction box, or similar fittings as conductors, feeders, branch circuits of other non-PV systems, or
inverter output circuits unless the conductor of the different systems are separated by a partition. PV system
circuit conductors shall be identified and grouped as required by 690.31(13)(1) through (4). The means of
identification shall be permitted by separate color coding, marking tape, tagging, or other approved means
(CEC §690.31(13))
BSOL2021-0201 - 81359 PEARY PLACE
REVISION 2
REVISED PANEL WATTAGE 325W TO 365W FOR A
SYSTEM SIZE OF 13.87KW [PROCTOR
ENGINEERING]. NO OTHER CHANGES TO
SYSTEM. 2019 CALIFORNIA BUILDING CODES.
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2022
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
0
FO=
Approved by: aS
Brandon Slater (760) 895-9474
Project Description
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
ing Number:l REV: #
21-038
Scale: I Sheet 1 of 5
Legend:
Orientatio
Array Tilt:
FIREFIGHT
ACCESS P(
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE 07/14/2022 13Y D C
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
Solar array - Roof Mount (N)
38 @ REC365TP4 Black Panels with 38
@ IQ7PLUS-72-2-US microinverters
13.870 kW - DC
11.210 kW - AC inverter output
Inverter AC Peak Output 295VA
295 x 38 = 11.210kW
(E)
Existing
(N)
New
PL
Property Line
❑
Skylight
Vent
Chimney
VECTOR
E n 0 1 Il E E R S
657 W. GALENA PA RK BLVD. - 7D1 PHONE (BD I) 99D-7775
DRAPER, Ll- B4D2D -W. VEc-E.-
OFCA�\F��
07/13/2022
VSE Project Number: U2398.0022.211
Vector Structural Engineering has reviewed the existing
structure with loading from the solar array and screw
connections to the existing framing. The design of the
racking system, racking connections, and all other
structural is by others. Mechanical, architectural, and all
other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2022
Approved by: 2�5'
Brandon Slater (760) 895-9474
Site Plan
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
Drawing Number:
I REV: # I Scale: 1/16" = 1' I Sheet 2 of 5
(N) Solar Array
38 @ REC365TP4 Black panels
69.1 " x 40.94" x 1.2"
iiffl
25'
Roof Section Scale 3/8" = 1'
;FESSio >YECTOR
•9� n 9 1 n E E R s
S• PR C 651 W. GALENA PA FK BLVD. S- 101 PHONE (B07) 990-7775
2 DRAPER, U-H B4020 WWW.VECTORSE.-
m
5 VSE Project Number: U2398.0022.211
t�l
9TFOFCA��F�
Vector Structural Engineering has reviewed the existing
structure with loading from the solar array and screw
connections to the existing framing. The design of the
racking system, racking connections, and all other
07/13/2022
structural is by others. Mechanical, architectural, and all
other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
(E) 2 x 4 Rafters @ 24" OC with V8„ OSB Sheathing
and Modified Bitumen Roofing Material
Roof Pitch: 1'
iilliff'01
2 x 4 Rafters @ 24" OC
Legend:
(E) Existing
(N) New
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2022
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE 07/14/2022 sti--D C
(N) ProSolar Residential Rail,
anodized aluminum 1.5" x 1.5"
(N) ProSolar Solar Wedge 5° Kit
72" OC with 3/8" x 6" Lag Bolts
(E) 2 x 4 Rafters 24" OC
Attachment Detail Scale 1 If
= 1'
Approved by: a5
Brandon Slater (760) 895-9474
Attachment Detail
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer: I Madison Club I 81359 Peary Place
Lot 59A La Quinta, CA, 92253
g Number:
l REV: #
Scale: I Sheet 3 of 5
PV Array (N)
3 Branch Circuits of 12 and 2 x 13 Modules in Parallel on Roof
(38) REC365TP4 Black Panels
(38) Enphase IQ7PLUS-72-2-US Microinverters under panels
Output: 13,870 Watts STC
SUM OF INVERTER OUTPUT:
1.21 Amp x 38 x 125% = 57.475 Amp
Legend:
(E) Existing
(N) New
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2022
Single Line Notes:
Junction Boxes (N
Weather proof Bell box
J-BOX
loperatin9 @ 125% = 18.15 A (1.21 A x 12 x 125%)
(2) # 12 THWN-2 - in Enphase Q Cable
Equipment Grounding Conductor:
(1) # 6 solid copper
Wire run under panels through inverters
loperatin9 @ 125% = 19.6625 A (1.21 A x 13 x 125%)
(2) # 12 THWN-2 - in Enphase Q Cable
Equipment Grounding Conductor:
(1) # 6 solid copper
Wire run under panels through inverters
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
GATE 07/14/2022 �� C
Enphase IQ Combiner
X-IQ-AM 1-240-B
240 V
(N) 3 x Solar Breakers
2P20Amp
AC Disconnect (
2P60A - Non -Fused
240 V
NEMA 3R
Located next to
Main Electrical Panel
(6) # 10 THWN-2
(1) # 8 THWN-2 (AC-EGC) L
3/4" EMT Conduit on Roof
Wire Sizing:
# 10 THWN-2 - 40A
40A x 80% (conduit fill) x 0.65 (temp. correction) = 20.8 A
Conduit is more than 3.5" above roof surface
1. The DC circuit meets the requirements of ungrounded PV arrays in NEC 690.35.No additional GEC is
required. Ground Fault Protection is integrated into the inverter.
2. All wire sizes are as indicated or larger. ELECTRICAL ONLY
3. Wire sizes meet the criteria of 125% continuous use factor. Q�OFESSi
4. All equipment is bonded by mechanical means or by a grounding conductor. LE VO
5. All modules are grounded mechanically using Prosolar Grounding System.
6. The system is grounded at the neutral buss in the main electrical panel. o z m
E 12178
Lu
7. The system is grid - intertie only, has no batteries or UPS.
8. Individual panels inverted from DC to AC with microinverters located under panels.
9. The Enphase Q Cable System (double insulated DG cable) does not have neutral win
�F
N1 Main Service Panel (E
600 Amp Main Service
Bussbar Rated @ 600 Amps
Main Breaker:
(E)2P600Am[
Utility Meter
- 3.96 rcWrr
Utility Grid
1201240V
(N) Solar Breaker
(2) # 6 THHN/THWN-2
(1) # 6 THHN/THWN-2 AC - EGC
1" EMT Conduit
Wire Sizing:
# 6 THWN-2 - 75A
75A x 100% (conduit fill) x 0.82 (temp. correction) = 61.5A
AUTOMATIC RAPID SHUTDOWN UPON AC GRID
DISCONNECT INTEGRATED IN ENPHASE INVERTERS
TO MEET NEC 2017
07/13/2022
VSE Project Number: U2398.0022.211
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
�YECTOR
n O I n E E R S
657 W. GALENA PARK SLVD, STE. 707 PHONE (807) 990-7775
DRAPER, L7TAm 64020 .—VED—I.E. DD.
Approved by: r35
Brandon Slater (760) 895-9474
1 - Line
45-350 San Luis Rey
Southern California Palm Desert, CA 92260
Contractor: Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
rawingNumberREV: # Scale: Sheet 4 of 521-038 I�I
NEC 690.64(B)(7)
PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION
EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE))
THIS LABEL IS ONLY NECESSARY WHEN BREAKERS FEEDING
PANEL EXCEEDS 100% OF BUSS RATING
MAIN SERVICE PANEL
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT
DOWN PV SYSTEM AND
REDUCE SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
EXTERIOR / INTERIOR CONDUIT
NEC 690.54
PLACE THIS LABEL AT "INTERACTIVE POINT OF
INTERCONNECTION" (AT MAIN SERVICE PANEL AND
SUBPANEL IF APPLICABLE)
SOLAR ONLY SUBPANEL 12 PANEL CIRCUITS:
SOLAR ONLY SUBPANEL 13 PANEL CIRCUITS:
MAIN SERVICE PANEL:
VECTOR
E n O I n E E R S
65 i W. GALENA PARK BLVD. STE. 101 PHONE (HOT) 990- 1 775
DRAPER, UTAH B4020 WWW. VECTORBE. COM
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
ATE 07/14/2022 E;)--D C
ELECTRICAL ONLY
Q�OFESS�O
�0 P.LEV��'9!
w E 12178 m
07/13/2022
VSE Project Number: U2398.0022.211
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
NEC 690.56(B)
BUILDINGS OR STRUCTURES WITH BOTH UTILITY SERVICE
AND PHOTOVOLTAIC SYSTEM SHALL HAVE A PERMANENT
PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE
SERVICE DISCONNECTING MEANS AND THE PV SYSTEM
DISCONNECTING MEANS IF NOT LOCATED AT THE SAME
10('ATION_
AC DISCONNECT - READILY ACCESSIBLE:
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2-2022
Approved by:
Brandon Slater (760) 895-9474
Labels
45-350 San Luis Rey
Contractor: Southern California Palm Desert, CA 92260
Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
rawing Number:) REV: # I Scale: I Sheet 5 of 5
21-038
PLACARD FOR MAIN SERVICE PANEL:
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN:
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
i,.. 07/14/2022 �� C
MA
81359 PEARY PLACE
LA QUINTA, CA, 92253
DISCLAIMER: If any Errors, Discrepancies or Omissions appear in these drawings, specifications or other contract documents; The Owner or General Contractor shall notify the Designer, in writing,
of such error or omission. In the event that the Owner or General Contractor falls to give such notice, before construction and/or fabrication of the work, the Owner or General Contractor will be
held responsible to the result of any errors, discrepancies or omissions and the cost of rectifying them.
VECTOR
E n (3 1 n E E R 8
657 W. GALENA PARK BLVD. STE. 707 PHONE (807) 990-7775
DRAPER, UTAH H4020 WWW.VE-SE.-
ELECTRICAL ONLY
Q�p F E S'Sip',
LEI 0
�P ofi G)
60 E12178 7-2w m
07/13/2022
VSE Project Number: U2398.0022.211
Approvals
Date
Drawn:
10/15/2021
REV
7/12/2022
Approved by:
Brandon Slater (760) 895-9474
PLACARD
45-350 San Luis Rey
Contractor: Southern California Palm Desert, CA 92260
Energy Alternatives 760-904-4917
CSLB # 988895
Customer: Madison Club 81359 Peary Place
Lot 59A I La Quinta, CA, 92253
rawing Number:) REV: # I Scale: I Sheet 1 of 1
21-038