PGA West Signature - Jewel TR 36537 (PSN 05761) BCPR2021-0019 (Plan 1) Solar PlansWOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
M
C
SYMBOLS AND ABBREVIATIONS:
MAIN SERVICE PANEL AND POINT OF INTERCONNECTION
PV SYSTEM AC DISCONNECT
PV SYSTEM COMBINER PANEL
UTILITY PRODUCTION METER
PV COVER
AC
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
P
LONGI LR4-60HPB-355M MODULES WITH ENPHASE ENERGY IQ7PLUS-72-2-US MOUNTED
TO THE BACK OF EACH MODULE.
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
A
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
S
A
N
D
E
L
E
C
T
R
I
C
A
L
12
/
1
/
2
0
2
1
B
SE
C
O
N
D
R
E
V
I
E
W
C
O
R
R
E
C
T
I
O
N
S
1/
1
8
/
2
0
2
2
SHEET INDEX:
PV COVER COVER SHEET
PV RL 1.0 PV LAYOUTS
PV EE 1.0 ELECTRICAL
PV SR 1.0 STRUCTURAL
PV SR 2.0 STRUCTURAL
PV CS 1.0 CUTSHEETS
PV CS 2.0 CUTSHEETS CONT.
GOVERNING CODES:
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
1.2019 CA BUILDING CODE
2.2019 CA ENERGY CODE
3.2019 CA ELECTRICAL CODE
4.2019 CA FIRE CODE
5.2019 CA GREEN CODE
6.2019 CA MECHANICAL CODE
7.2019 CA PLUMBING CODE
8.2019 CA RESIDENTIAL CODE
9.ANY OTHER LOCAL AMENDMENTS
10.LA QUINTA MUNICIPAL CODE
GENERAL NOTES:
1.ELECTRICAL
1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR
SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE.
1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN
COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE.
1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS.
2.STRUCTURAL
2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY
SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE
STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2"
PENETRATION INTO ROOF FRAMING.
2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM.
2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
2.5.GROUND SNOW LOAD = 0 psf
2.6.WIND SPEED = 130 mph
2.7.EXPOSURE CATEGORY = C
SCOPE OF WORK
3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH JEWEL
3.1.PLAN: 1
3.2.ELEVATIONS: A, B, C
4.BUILDING INFORMATION:
4.1.BUILDING OCCUPANCY GROUP: R3/U
4.2.CONSTRUCTION TYPE: VB
5.PV
5.1.INVERTER: ENPHASE ENERGY IQ7PLUS-72-2-US
5.2.JEWEL TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE:
5.2.1.LONGI LR4-60HPB-355M
5.3.JEWEL TO UTILIZE THE FOLLOWING SYSTEM SIZES:
5.3.1.14 MODULES 4.970kW DC / 4.503kW AC
5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV
EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT.
BCPR2021-0019
LA QUINTA BY WOODBRIDGE/SIGNATURE -- SOLAR
PHOTOVOLTAIC MASTER PLANS FOR THE JEWEL
SERIES. PLANS 1, 2, 2 DUPLEX, & 3 DUPLEX FOR
THE 2019 CODE CYCLE. 2019 CALIFORNIA
BUILDING CODES.
PLAN 1, 2 & 2 DUPLEX: 4.97kW SOLAR ARRAY - (14)
355W LONGI SOLAR LR4-60HPB-355M MODULES +
ENPHASE IQ7PLUS-72-2-US MICROINVERTERS +
125A ENPHASE IQ COMBINER PANEL [280SF].
PLAN 3 DUPLEX: 3.905kW SOLAR ARRAY - (11)
355W LONGI SOLAR LR4-60HPB-355M MODULES +
ENPHASE IQ7PLUS-72-2-US MICROINVERTERS +
125A ENPHASE IQ COMBINER PANEL [220SF].
PLAN 1
04/14/2022
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
M
C
PV RL 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 1
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: B
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: C
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: C
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: B
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: A
GARAGE: REAR LEFT
SCALE: 5/64" = 1'-0"
ELEVATION: A
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
ELEVATION: B
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
ELEVATION: C
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
ELEVATION: A
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
ELEVATION: B
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
ELEVATION: C
GARAGE: REAR RIGHT
SCALE: 5/64" = 1'-0"
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
14 MODULES AT 4.970 kW DC
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
04/14/2022
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
A
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
S
A
N
D
E
L
E
C
T
R
I
C
A
L
12
/
1
/
2
0
2
1
04/14/2022
STRUCTURAL
MOUNT DETAILS
PV SR 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
1 SNAPNRACK ULTRA RAIL STANDOFF BASE
NOT TO SCALE 2 SNAPNRACK GROUND LUG R PRC
NOT TO SCALE
4 SNAPNRACK CONDUIT MOUNT DETAIL
NOT TO SCALE
SHEATHING, TYP.
SNAPNRACK STANDOFF
BASE STD 4-HOLE, TYP SUB-FLASHING CONE, TYP
FLASHING
CONE, TYP
TILE, TYP
CONDUIT SUPPORT
CONDUIT
TILE HOOK
TILE, TYP
SHEATHING, TYP
NOTE: TILE HOOK TO BE PLACED AT
THE HIGH POINT OF S & W TILES
SEAL PENETRATION AND BASE
WITH CHEMLINK DURALINK 35
05.17.2021
FRAMING, TYP.
2-1/2"(2) 5/16" SS LAG
SCREW, TYP.
3 SNAPNRACK MOUNT SPACING TYP.
NOT TO SCALE
CANTILEVER
L/3 OR
LESS
LANDSCAPE:
MAX 48"
SPACING (L)
PORTRAIT:
MAX 48"
SPACING (L)
MODULE, TYP.
FRAMING, TYP.
CANTILEVER
L/3 OR
LESS
MID CLAMP, TYP.MAX 10" - 16"
CANTILEVER,
TYP *
MAX
10"-16"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP
*
MAX
10"
CANTILEVER,
TYP *
UR-60 RAIL, TYP.
ENDCLAMP, TYP.
*DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE
THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER
ULTRA FOOT,
TYP.
SIDE VIEW
BONDING CHANNEL NUT
CONDUCTOR CONNECTS TO
ANOTHER GROUND LUG ON
BOTTOM RAIL OF ABOVE ROW
OF MODULES
GROUND LUG R PRC
SS SPLIT LOCK WASHER
GROUND CONDUCTOR
UR-60 RAIL
FRONT VIEW
UR-60 RAIL
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
B
SE
C
O
N
D
R
E
V
I
E
W
C
O
R
R
E
C
T
I
O
N
S
1/
1
8
/
2
0
2
2
04/14/2022
STRUCTURAL
GENERAL FRAMING INFORMATION
PV SR 2.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
04/14/2022
PV CS 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
A
UP
D
A
T
E
D
E
L
E
C
T
R
I
C
A
L
12
/
1
/
2
0
2
1
CUTSHEETS
MICROINVERTER
COMBINER PANEL
MODULE
04/14/2022
CUTSHEETS CONT.
RACKING
PV CS 2.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 1
DATE: 1/18/2022
RE
V
I
S
I
O
N
S
RE
V
DE
S
C
R
I
P
T
I
O
N
DA
T
E
04/14/2022