Loading...
PGA West Signature - Jewel TR 36537 (PSN 05763) BCPR2021-0019 (Plan 1) Solar Plans - Revision 1WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA M C SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT PV SYSTEM COMBINER PANEL UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 1 DATE: 4/21/2022 P LONGI LR4-60HPB-355M MODULES WITH ENPHASE ENERGY IQ7PLUS-72-2-US MOUNTED TO THE BACK OF EACH MODULE. RE V I S I O N S RE V DE S C R I P T I O N DA T E A UP D A T E D S Y S T E M S I Z E S A N D E L E C T R I C A L 12 / 1 / 2 0 2 1 B SE C O N D R E V I E W C O R R E C T I O N S 1/ 1 8 / 2 0 2 2 C AD D E D L A Y O U T S - P L A N 1 4/ 2 1 / 2 0 2 2 GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH JEWEL 3.1.PLAN: 1 3.2.ELEVATIONS: A, B, C 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: ENPHASE ENERGY IQ7PLUS-72-2-US 5.2.JEWEL TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: 5.2.1.LONGI LR4-60HPB-355M 5.3.JEWEL TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.14 MODULES 4.970kW DC / 4.503kW AC 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV SR 1.0 STRUCTURAL PV SR 2.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS 10.LA QUINTA MUNICIPAL CODE REVISION 1 BCPR2019-0019 ADDED ROOF LAYOUTS FOR PLANS 1 & 2 05/26/2022 PLAN 2 M C M C M C M C M C M C M C M C M C M C M C M C PV RL 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 1 DATE: 4/21/2022 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 LAYOUT 1 LAYOUT 2 LAYOUT 3 LAYOUT 4 RE V I S I O N S RE V DE S C R I P T I O N DA T E PV ROOF LAYOUTS PLAN 1 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: B GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: B GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: A GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: A GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: B GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: A GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: B GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE 05/26/2022 M C M C M C M C PV RL 2.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 1 DATE: 4/21/2022 LAYOUT 5 LAYOUT 6 LAYOUT 5 LAYOUT 6 RE V I S I O N S RE V DE S C R I P T I O N DA T E C AD D E D L A Y O U T S 5 & 6 F O R P L A N 1 E L E V A T I O N S B & C 4/ 2 1 / 2 0 2 2 PV ROOF LAYOUTS PLAN 1 FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 5/64" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" ELEVATION: B GARAGE: REAR RIGHT SCALE: 5/64" = 1'-0" OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 05/26/2022