Loading...
PGA West Signature - Jewel TR 36537 (PSN 05767) BCPR2021-0019 (Plan 2) Duplex Solar PlansWOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA M C SYMBOLS AND ABBREVIATIONS: MAIN SERVICE PANEL AND POINT OF INTERCONNECTION PV SYSTEM AC DISCONNECT PV SYSTEM COMBINER PANEL UTILITY PRODUCTION METER PV COVER AC PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 P LONGI LR4-60HPB-355M MODULES WITH ENPHASE ENERGY IQ7PLUS-72-2-US MOUNTED TO THE BACK OF EACH MODULE. RE V I S I O N S RE V DE S C R I P T I O N DA T E A UP D A T E D S Y S T E M S I Z E S A N D E L E C T R I C A L 12 / 1 / 2 0 2 1 B SE C O N D R E V I E W C O R R E C T I O N S 1/ 1 8 / 2 0 2 2 SHEET INDEX: PV COVER COVER SHEET PV RL 1.0 PV LAYOUTS PV RL 2.0 PV LAYOUTS CONT. PV EE 1.0 ELECTRICAL PV SR 1.0 STRUCTURAL PV SR 2.0 STRUCTURAL PV CS 1.0 CUTSHEETS PV CS 2.0 CUTSHEETS CONT. GOVERNING CODES: ALL WORK SHALL CONFORM TO THE FOLLOWING CODES 1.2019 CA BUILDING CODE 2.2019 CA ENERGY CODE 3.2019 CA ELECTRICAL CODE 4.2019 CA FIRE CODE 5.2019 CA GREEN CODE 6.2019 CA MECHANICAL CODE 7.2019 CA PLUMBING CODE 8.2019 CA RESIDENTIAL CODE 9.ANY OTHER LOCAL AMENDMENTS 10.LA QUINTA MUNICIPAL CODE GENERAL NOTES: 1.ELECTRICAL 1.1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. 1.2.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE. 1.3.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE. 1.4.SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS. 2.STRUCTURAL 2.1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.2.UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2" PENETRATION INTO ROOF FRAMING. 2.3.THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. 2.4.ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2.5.GROUND SNOW LOAD = 0 psf 2.6.WIND SPEED = 130 mph 2.7.EXPOSURE CATEGORY = C SCOPE OF WORK 3.SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH JEWEL 3.1.PLAN: 2 DUPLEX 3.2.ELEVATIONS: A, B, C 4.BUILDING INFORMATION: 4.1.BUILDING OCCUPANCY GROUP: R3/U 4.2.CONSTRUCTION TYPE: VB 5.PV 5.1.INVERTER: ENPHASE ENERGY IQ7PLUS-72-2-US 5.2.JEWEL TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE: 5.2.1.LONGI LR4-60HPB-355M 5.3.JEWEL TO UTILIZE THE FOLLOWING SYSTEM SIZES: 5.3.1.14 MODULES 4.970kW DC / 4.503kW AC PER UNIT 5.4.ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT. BCPR2021-0019 LA QUINTA BY WOODBRIDGE/SIGNATURE -- SOLAR PHOTOVOLTAIC MASTER PLANS FOR THE JEWEL SERIES. PLANS 1, 2, 2 DUPLEX, & 3 DUPLEX FOR THE 2019 CODE CYCLE. 2019 CALIFORNIA BUILDING CODES. PLAN 1, 2 & 2 DUPLEX: 4.97kW SOLAR ARRAY - (14) 355W LONGI SOLAR LR4-60HPB-355M MODULES + ENPHASE IQ7PLUS-72-2-US MICROINVERTERS + 125A ENPHASE IQ COMBINER PANEL [280SF]. PLAN 3 DUPLEX: 3.905kW SOLAR ARRAY - (11) 355W LONGI SOLAR LR4-60HPB-355M MODULES + ENPHASE IQ7PLUS-72-2-US MICROINVERTERS + 125A ENPHASE IQ COMBINER PANEL [220SF]. PLAN 2 DUPLEX 04/14/2022 M M UNIT 2 UNIT 3 C C MM UNIT 2UNIT 3 CC M M UNIT 2 UNIT 3 C C M M UNIT 2 UNIT 3 C C MM UNIT 2UNIT 3 CC M M UNIT 2 UNIT 3 C C M M UNIT 2 UNIT 3 C C PV RL 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 LAYOUT 1 LAYOUT 2 RE V I S I O N S RE V DE S C R I P T I O N DA T E PV ROOF LAYOUTS PLAN 2 DUPLEX FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: A GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: A GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: B GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: B GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: A GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: A GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: B GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE LAYOUT 3 LAYOUT 4 LAYOUT 1 LAYOUT 2 LAYOUT 3 PER UNIT PER UNIT PER UNIT PER UNIT PER UNIT PER UNIT PER UNIT 04/14/2022 MM UNIT 2UNIT 3 C C M M UNIT 2 UNIT 3 C C MM UNIT 2UNIT 3 CC MM UNIT 2UNIT 3 CC M M UNIT 2 UNIT 3 C C MM UNIT 2UNIT 3 CC M M UNIT 2 UNIT 3 C C MM UNIT 2UNIT 3 C C MM UNIT 2UNIT 3 C C PV RL 2.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 LAYOUT 4 LAYOUT 5 RE V I S I O N S RE V DE S C R I P T I O N DA T E PV ROOF LAYOUTS PLAN 2 DUPLEX FIRECODE OFFSET: RIDGE: 18" RAKE: 36" HIP/VALLEY: 18" PV SYSTEM WILL CONFORM TO ALL APPLICABLE GOVERNING CODES AS OUTLINED ON PV COVER PAGE, NOT TO EXCEED 3.8 kW AC CAPACITY, NOR TO BLOCK OR COVER ANY ROOF PLUMBING OR VENTILATION. ELEVATION: B GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: B GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR LEFT SCALE: 3/32" = 1'-0" ELEVATION: C GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC 14 MODULES AT 4.970 kW DC LAYOUT 1 LAYOUT 2 LAYOUT 4 LAYOUT 5 LAYOUT 3 LAYOUT 6 ELEVATION: B GARAGE: REAR RIGHT SCALE: 3/32" = 1'-0" 14 MODULES AT 4.970 kW DC OPTION(S): NONE LAYOUT 6 PER UNIT PER UNIT PER UNIT PER UNITPER UNITPER UNIT PER UNIT PER UNIT PER UNIT 04/14/2022 ELECTRICAL THREE LINE DIAGRAM WARNING LABELS LABEL GUIDE PV EE 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E A UP D A T E D S Y S T E M S I Z E S A N D E L E C T R I C A L 12 / 1 / 2 0 2 1 04/14/2022 STRUCTURAL MOUNT DETAILS PV SR 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 1 SNAPNRACK ULTRA RAIL STANDOFF BASE NOT TO SCALE 2 SNAPNRACK GROUND LUG R PRC NOT TO SCALE 4 SNAPNRACK CONDUIT MOUNT DETAIL NOT TO SCALE SHEATHING, TYP. SNAPNRACK STANDOFF BASE STD 4-HOLE, TYP SUB-FLASHING CONE, TYP FLASHING CONE, TYP TILE, TYP CONDUIT SUPPORT CONDUIT TILE HOOK TILE, TYP SHEATHING, TYP NOTE: TILE HOOK TO BE PLACED AT THE HIGH POINT OF S & W TILES SEAL PENETRATION AND BASE WITH CHEMLINK DURALINK 35 05.17.2021 FRAMING, TYP. 2-1/2"(2) 5/16" SS LAG SCREW, TYP. 3 SNAPNRACK MOUNT SPACING TYP. NOT TO SCALE CANTILEVER L/3 OR LESS LANDSCAPE: MAX 48" SPACING (L) PORTRAIT: MAX 48" SPACING (L) MODULE, TYP. FRAMING, TYP. CANTILEVER L/3 OR LESS MID CLAMP, TYP.MAX 10" - 16" CANTILEVER, TYP * MAX 10"-16" CANTILEVER, TYP * MAX 10" CANTILEVER, TYP * MAX 10" CANTILEVER, TYP * UR-60 RAIL, TYP. ENDCLAMP, TYP. *DEFER TO MODULE MANUFACTURER LIMITATIONS WHERE THEIR MAXIMUM VERTICAL CANTILEVER IS SMALLER ULTRA FOOT, TYP. SIDE VIEW BONDING CHANNEL NUT CONDUCTOR CONNECTS TO ANOTHER GROUND LUG ON BOTTOM RAIL OF ABOVE ROW OF MODULES GROUND LUG R PRC SS SPLIT LOCK WASHER GROUND CONDUCTOR UR-60 RAIL FRONT VIEW UR-60 RAIL RE V I S I O N S RE V DE S C R I P T I O N DA T E B SE C O N D R E V I E W C O R R E C T I O N S 1/ 1 8 / 2 0 2 2 04/14/2022 STRUCTURAL GENERAL FRAMING INFORMATION PV SR 2.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E 04/14/2022 PV CS 1.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E A UP D A T E D E L E C T R I C A L 12 / 1 / 2 0 2 1 CUTSHEETS MICROINVERTER COMBINER PANEL MODULE 04/14/2022 CUTSHEETS CONT. RACKING PV CS 2.0 PV SYSTEM PROVIDED BY: 1.877.404.4129 CA LICENSE: B/C46/C10/C36-750184 HOME DEVELOPER: WOODBRIDGE PACIFIC LA QUINTA, CA 92253 JEWEL LA QUINTA, CA PLAN: 2 DUPLEX DATE: 1/18/2022 RE V I S I O N S RE V DE S C R I P T I O N DA T E 04/14/2022