PGA West Signature - Jewel TR 36537 (PSN 05770) BCPR2021-0019 (Plan 3) Duplex Solar - Revision 2WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN 3 DUPLEX
M
C
SYMBOLS AND ABBREVIATIONS:
MAIN SERVICE PANEL AND POINT OF INTERCONNECTION
PV SYSTEM AC DISCONNECT
PV SYSTEM COMBINER PANEL
UTILITY PRODUCTION METER
PV COVER
AC
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 3 DUPLEX
DATE: 8/18/2022
P
LONGI LR4-60HPB-355M MODULES WITH ENPHASE ENERGY IQ7PLUS-72-2-US MOUNTED
TO THE BACK OF EACH MODULE.
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
A
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
S
A
N
D
E
L
E
C
T
R
I
C
A
L
12
/
1
/
2
0
2
1
B
SE
C
O
N
D
R
E
V
I
E
W
C
O
R
R
E
C
T
I
O
N
S
1/
1
8
/
2
0
2
2
SHEET INDEX:
PV COVER COVER SHEET
PV RL 1.0 PV LAYOUTS
PV RL 2.0 PV LAYOUTS CONT.
PV RL 3.0 PV LAYOUTS CONT.
PV EE 1.0 ELECTRICAL
PV SR 1.0 STRUCTURAL
PV SR 2.0 STRUCTURAL
PV CS 1.0 CUTSHEETS
PV CS 2.0 CUTSHEETS CONT.
GENERAL NOTES:
1. ELECTRICAL
1.1. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR
SUCH USE. FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
1.2. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE.
1.3. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE INVERTER. RAPID SHUTDOWN
COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE.
1.4. SEE *PV EE 1.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND SPECIFICATIONS.
2. STRUCTURAL
2.1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE ULTRARAIL SYSTEM BY
SNAPNRACK. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE
STAGGERED, WHERE POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
2.2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2 1/2"
PENETRATION INTO ROOF FRAMING.
2.3. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM.
2.4. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
2.5. GROUND SNOW LOAD = 0 psf
2.6. WIND SPEED = 130 mph
2.7. EXPOSURE CATEGORY = C
SCOPE OF WORK
3. SOLELY FOR THE INSTALLATION OF THE ROOFTOP MOUNTED PV SYSTEM(S) ASSOCIATED WITH JEWEL
3.1. PLAN: 3 DUPLEX
3.2. ELEVATIONS: A, B, C
4. BUILDING INFORMATION:
4.1. BUILDING OCCUPANCY GROUP: R3/U
4.2. CONSTRUCTION TYPE: VB
5. PV
5.1. INVERTER: ENPHASE ENERGY IQ7PLUS-72-2-US
5.2. JEWEL TO UTILIZE THE FOLLOWING SOLAR MODULE TYPE:
5.2.1. LONGI LR4-60HPB-355M
5.3. JEWEL TO UTILIZE THE FOLLOWING SYSTEM SIZES:
5.3.1. 11 MODULES 3.905kW DC / 3.538kW AC PER UNIT
5.4. ALL WIRING ASSOCIATED WITH PV SYSTEM TO BE RUN THROUGH ATTIC AND WITHIN WALLS, FROM ROOF TO PV
EQUIPMENT LOCATION, IN FLEXIBLE METALLIC CONDUIT.
GOVERNING CODES:
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
1. 2019 CA BUILDING CODE
2. 2019 CA ENERGY CODE
3. 2019 CA ELECTRICAL CODE
4. 2019 CA FIRE CODE
5. 2019 CA GREEN CODE
6. 2019 CA MECHANICAL CODE
7. 2019 CA PLUMBING CODE
8. 2019 CA RESIDENTIAL CODE
9. ANY OTHER LOCAL AMENDMENTS
10. LA QUINTA MUNICIPAL CODE
REVISION 2
BCPR2021-0019
EXTERIOR AC
DISCONNECTS ADDED FOR
ALL PLAN TYPES
09/08/2022
M M
UNIT 3R UNIT 3
C C ACAC
MM
UNIT 3RUNIT 3
CCAC AC
M M
UNIT 3R UNIT 3
C CAC AC
M M
UNIT 3R UNIT 3
C CAC AC
MM
UNIT 3RUNIT 3
CCAC AC
M M
UNIT 3R UNIT 3
C CAC AC
MM
UNIT 3RUNIT 3
CCAC AC
M M
UNIT 3R UNIT 3
C C ACAC M M
UNIT 3R UNIT 3
C C ACAC
PV RL 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 3 DUPLEX
DATE: 8/18/2022
LAYOUT 1 LAYOUT 2
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 3 DUPLEX
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
LAYOUT 4 LAYOUT 5
LAYOUT 1 LAYOUT 2
LAYOUT 6
LAYOUT 3
ELEVATION: A
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
11 MODULES AT 3.905 kW DC
OPTION(S): NONE
LAYOUT 3
PER UNIT PER UNIT
PER UNITPER UNITPER UNIT
PER UNIT PER UNIT PER UNIT
PER UNIT
09/08/2022
M M
UNIT 3R UNIT 3
C CAC AC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
M M
UNIT 3R UNIT 3
C CAC AC M M
UNIT 3R UNIT 3
C CAC AC
PV RL 2.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 3 DUPLEX
DATE: 8/18/2022
LAYOUT 4 LAYOUT 5
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 3 DUPLEX
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE OPTION(S): NONE
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
LAYOUT 7 LAYOUT 8
LAYOUT 10 LAYOUT 11
LAYOUT 9
LAYOUT 12
ELEVATION: B
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
11 MODULES AT 3.905 kW DC
OPTION(S): NONE
LAYOUT 6
PER UNIT PER UNIT PER UNIT
PER UNITPER UNITPER UNIT
PER UNIT PER UNIT PER UNIT
09/08/2022
M M
UNIT 3R UNIT 3
C C ACAC
MM
UNIT 3RUNIT 3
CC ACAC
MM
UNIT 3RUNIT 3
CC ACAC
M M
UNIT 3R UNIT 3
C C ACAC
PV RL 3.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 3 DUPLEX
DATE: 8/18/2022
LAYOUT 1 LAYOUT 2
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
PV ROOF LAYOUTS
PLAN 3 DUPLEX
FIRECODE OFFSET:
RIDGE: 18"
RAKE: 36"
HIP/VALLEY: 18"
PV SYSTEM WILL CONFORM TO ALL
APPLICABLE GOVERNING CODES AS
OUTLINED ON PV COVER PAGE, NOT
TO EXCEED 3.8 kW AC CAPACITY, NOR
TO BLOCK OR COVER ANY ROOF
PLUMBING OR VENTILATION.
ELEVATION: C
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: C
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: C
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
ELEVATION: C
GARAGE: REAR CENTER
SCALE: 3/32" = 1'-0"
OPTION(S): NONE OPTION(S): NONE
OPTION(S): NONE OPTION(S): NONE
11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC 11 MODULES AT 3.905 kW DC
11 MODULES AT 3.905 kW DC
LAYOUT 3 LAYOUT 4
PER UNIT PER UNIT
PER UNIT PER UNIT
09/08/2022
ELECTRICAL
THREE LINE DIAGRAM
WARNING LABELS
LABEL GUIDE
PV EE 1.0
PV SYSTEM PROVIDED BY:
1.877.404.4129
CA LICENSE:
B/C46/C10/C36-750184
HOME DEVELOPER:
WOODBRIDGE PACIFIC
LA QUINTA, CA 92253
JEWEL
LA QUINTA, CA
PLAN: 3 DUPLEX
DATE: 8/18/2022
RE
V
I
S
I
O
N
S
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
A
UP
D
A
T
E
D
S
Y
S
T
E
M
S
I
Z
E
S
A
N
D
E
L
E
C
T
R
I
C
A
L
12
/
1
/
2
0
2
1
D
AD
D
E
D
E
X
T
E
R
I
O
R
A
C
D
I
S
C
O
N
N
E
C
T
8/
1
8
/
2
0
2
2
09/08/2022