PGA West - Signature TR 36537 (PSN 05758) BCPR2021-0014 - Solar Master PlansCOVER SHEET PV-1.0 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 C GENERAL NOTES PROJECT LOCATION SHEET INDEX PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 GENERAL STRUCTURAL INFORMATION PV-3.0 LAYOUT-PLAN 1 PV-3.1 LAYOUT-PLAN 2 PV-3.2 LAYOUT-PLAN 3 PV-3.3 LAYOUT-PLAN 4 PV-3.4 LAYOUT-PLAN 5 PV-3.5 LAYOUT-PLAN 6 PV-3.6 LAYOUT-PLAN 7 PV-3.7 LAYOUT-PLAN 8 PV-4.0 15 & 16 MODULE ELECTRICAL DIAGRAMS PV-4.1 17 MODULE ELECTRICAL DIAGRAMS PV-5.0 SPEC SHEETS MASTER PV SOLAR PLAN "LA QUINTA BY WOODBRIDGE PACIFIC" CITY OF LA QUINTA, CALIFORNIA PV SYSTEM INFORMATION SYSTEM SIZE: 5250W DC (BASE); 5600 DC (BASE); 5950 DC (BASE) MODULES: BASE-(15) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M ; BASE-(16) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M ; BASE-(17) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M INVERTER(S): BASE-(15) ENPHASE ENERGY: IQ7PLUS-72-2-US; BASE-(16) ENPHASE ENERGY: IQ7PLUS-72-2-US; BASE-(17) ENPHASE ENERGY: IQ7PLUS-72-2-US RACKING: SNAPNRACK SERIES UR40; ULTRA RAIL SPEEDFOOT, SEE DRAWING SNR-DC-00438, ET AL. CONTACT INFORMATION BUILDER: WOODBRIDGE PACIFIC GROUP, LLC 27271 LAS RAMBLAS, SUITE 100 MISSION VIEJO, CA 92691 PH: 949.348.8162 SOLAR INSTALLER: SUNRUN INSTALLATION SERVICES 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PH: 805.540.7603 ARCHITECT: HANNOUCHE ARCHITECTS 20250 ACACIA STREET, SUITE 145 NEWPORT BEACH, CA 92660 PH: 949.261.2070 PROJECT LOCATION PROJECT LOCATION SCALE: NTS MAIN PANEL INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL MP SP LC SM PM INV AC DC CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SE SERVICE ENTRANCE COMBINER BOX HARDSCAPE PROPERTY LINE INTERIOR EQUIPMENT SHOWN AS DASHED PLREVISION SYMBOL TITLE 24 REQUIRMENTS LEGEND & ABBREVIATIONS RAIL STANDOFFS & FOOTINGS SOLAR MODULES SYSTEM UPSIZE OPTION • 15.45 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • 9.89 AMPS MODULE SHORT CIRCUIT CURRENT. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER 690.12(B). • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL MODULES, ARE CLASS A FIRE RATED. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41. • PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2019 CEC. CRC§R324.6. ROOF LAYOUTS. ALL FIRE SETBACKS AND CLEARANCES TO CONFORM WITH • TWO 36" FIRE PATHWAYS FROM FRONT/BACK OF EACH HOME PROVIDED WITH AND INSTALLATION INSTRUCTIONS. AND THE LA QUINTA MUNICIPAL CODE, AND ALLMANUFACTURERS' LISTINGS MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, ANDGREEN BUILDING CODES • ALL WORK SHALL COMPLY WITH 2019 CALIFORNIABUILDING, RESIDENTIAL, C C BCPR2021-0014 LA QUINTA BY WOODBRIDGE / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1-8 FOR THE 2019 CODE CYCLE. 2019 CALIFORNIA BUILDING CODES. PLAN 1: 5.25kW SOLAR ARRAY - (15) 350W LONGI SOLAR LR4-60HPB-350M MODULES + ENPHASE IQ7PLUS-72-2-US MICROINVERTERS [270SF]. PLAN 2, 3, 4 & 5: 5.6kW SOLAR ARRAY - (16) 350W LONGI SOLAR LR4-60HPB-350M MODULES + ENPHASE IQ7PLUS-72-2-US MICROINVERTERS [288SF]. PLAN 6, 7 & 8: 5.95kW SOLAR ARRAY - (17) 350W LONGI SOLAR LR4-60HPB-350M MODULES + ENPHASE IQ7PLUS-72-2-US MICROINVERTERS [306SF]. 07/20/2021 (SIGNATURE) STRUCTURAL PV-2.0 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 MODULE ELEVATIONS SOLAR MODULE SNAPNRACK RACKING 6" RLU (COMP) ELEVATION - SCALE: NTS SOLAR MODULE SNAPNRACK RACKING 4" UR-S TILE ELEVATION - SCALE: NTS SOLAR MODULE SNAPNRACK RACKING AND TILE ROOF HOOK UR-FLAT TILE ELEVATION - SCALE: NTS 3" SOLAR MODULE SNAPNRACK RACKING UR W-TILE ELEVATION - SCALE: NTS 3" FRAMING DETAIL VARIOUS ROOF TYPE SOLAR MODULE 5/16" X 4.5" LAG SCREW 2X4 PRE-FABRICATED TRUSSES, 24" O.C. V A R I E S TRUSS FRAMING DETAIL - SCALE: NTS MODULES: LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPH-350M MODULE DIMS: 66.3" x 39.4" x 1.259" (32mm) MODULE CLAMPS: Portrait: 9.84" - 17.72" Landscape: 0" - 9.84" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 130 MPH 3-SEC GUST. LAG SCREWS: 5/16"x4.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. DESIGN CRITERIA-GENERAL PENETRATION SPACING: STAGGERED/FULLY STAGGERED MAY BE REQUIRED PENETRATION SPACING-GENERAL RLU (COMP) SPACING - SCALE: 3 8" = 1'-0"UR (ALL) STACKED SPACING - SCALE: 3 8" = 1'-0" UR (ALL) STAGGERED SPACING - SCALE: 3 8" = 1'-0" 6' 6' 6' UR (ALL) FULLY STAGGERED SPACING - SCALE: 3 8" = 1'-0" 6' 4' GENERAL NOTES THE INFORMATION PRESENTED ON THIS PAGE IS MEANT TO ILLUSTRATE GENERAL SURNUN MATERIALS AND INSTALLATION PRACTICES. THE INFORMATION HERE IS SUBJECT TO CHANGE. UNIQUE PLANS WILL BE CREATED FOR EACH BUILDING PRIOR TO CONSTRUCTION FOR REVIEW. 07/20/2021 LAYOUTS-PLAN 1 PV-3.0 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 5:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM PLAN 1 [SCALE 1/16" = 1'-0"] N PLAN TYPE STANDARD SYSTEM A 5250W FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5250W PLAN TYPE STANDARD SYSTEM A 5250W PLAN TYPE STANDARD SYSTEM A 5250W PLAN TYPE STANDARD SYSTEM B 5250W PLAN TYPE STANDARD SYSTEM B 5250W PLAN TYPE STANDARD SYSTEM B 5250W PLAN TYPE STANDARD SYSTEM B 5250W PLAN TYPE STANDARD SYSTEM C 5250W PLAN TYPE STANDARD SYSTEM C 5250W PLAN TYPE STANDARD SYSTEM C 5250W PLAN TYPE STANDARD SYSTEM C 5250W 07/20/2021 LAYOUTS-PLAN 2 PV-3.1 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 PLAN 2 [SCALE 1/16" = 1'-0"] N NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 5:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM PLAN TYPE STANDARD SYSTEM A 5600W FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W 07/20/2021 LAYOUT-PLAN 3 PV-3.2 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 PLAN 3 [SCALE 1/16" = 1'-0"] N NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 4:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM PLAN TYPE STANDARD SYSTEM A 5600W FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W 07/20/2021 LAYOUT-PLAN 4 PV-3.3 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 PLAN 4 [SCALE 1/16" = 1'-0"] N NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 5:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM PLAN TYPE STANDARD SYSTEM A 5600W FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W 07/20/2021 LAYOUT-PLAN 5 PV-3.4 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 PLAN 5 [SCALE 1/16" = 1'-0"] N NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 5:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM PLAN TYPE STANDARD SYSTEM A 5600W FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM A 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM B 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W PLAN TYPE STANDARD SYSTEM C 5600W 07/20/2021 PV-3.5 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 PLAN 6 [SCALE 1/16" = 1'-0"] N LAYOUT-PLAN 6 NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 5:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W 07/20/2021 LAYOUTS-PLAN 7 PV-3.6 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 N PLAN 7 [SCALE 1/16" = 1'-0"] NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 4:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W 07/20/2021 LAYOUTS-PLAN 8 PV-3.6 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 N PLAN 8 [SCALE 1/16" = 1'-0"] NOTES: ROOF TYPE, PER PERMITTED ARCHITECTURE PLANS, IS S-CONCRETE TILE. ALL PITCHES ARE 4:12, UNLESS OTHERWISE NOTED. INDIVIDUAL LOT PLANS MAY BE "MIRRORED" /SHOWN IN THE REVERSE PER BUILDER SPECIFICATIONS. IF SO, THEN THE NEAREST LAYOUT MAY BE SELECTED. EACH OPTION PER THE PERMITTED ARCHITECTURAL PLAN SET SHOWING VARIOUS PLAN AND ROOF CONFIGURATION FOR THE HOME BUYER TO SELECT FROM FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME FRONT OF HOME PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM A 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W PLAN TYPE STANDARD SYSTEM B 5950W PLAN TYPE STANDARD SYSTEM C 5950W 07/20/2021 NEW 200A MAIN BREAKER (END FED) FACILITY GROUND(N) 25A PV BREAKER AT OPPOSITE END OF BUSBAR M METER #: PGE TBD 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID NEW 200A MAIN PANELFACILITY LOADS 20A BREAKER [A] 20A BREAKER [B] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C JUNCTION BOX OR EQUIVALENT 12 (15) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M MODULES AND MICRO-INVERTER PAIRS (15) ENPHASE ENERGY: IQ7PLUS-72-2-US -- (1) BRANCH OF (8) MICRO-INVERTERS [A] (1) BRANCH OF (7) MICRO-INVERTERS [A] 3 CONDUIT SCHEDULE 1 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 CONDUIT SCHEDULE 2 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 ROMEX/NM-B (4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 ROMEX/NM-B (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 CONDUIT SCHEDULE 1 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 CONDUIT SCHEDULE 2 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 ROMEX/NM-B (4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 ROMEX/NM-B (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 NEW 200A MAIN BREAKER (END FED) FACILITY GROUND(N) 25A PV BREAKER AT OPPOSITE END OF BUSBAR M METER #: PGE TBD 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID NEW 200A MAIN PANELFACILITY LOADS 20A BREAKER [A] 20A BREAKER [B] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C JUNCTION BOX OR EQUIVALENT 12 (16) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M MODULES AND MICRO-INVERTER PAIRS (16) ENPHASE ENERGY: IQ7PLUS-72-2-US -- (1) BRANCH OF (8) MICRO-INVERTERS [A] (1)BRANCH OF (8) MICRO-INVERTERS [B] 3 15 & 16 MOD ELECTRICAL SYSTEM PV-4.0 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 ELECTRICAL DIAGRAM - 15 MODULE SYSTEM RAIL 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNEL NUT SS BONDING PINS NOTE: ·ALL HARDWARE IS INCLUDED FROM MANUFACTURER ·A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES ·GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ·GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL ·ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M : OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 320 W 40.29 V 33.46 V 9.89 A NOTES TO INSTALLER: ADD 25 AMP PV BREAKER TO MAIN PANEL. ELECTRICAL CALCULATIONS SIGNAGE & PLACARDS ELECTRICAL DIAGRAM - 1 6 MODULE SYSTEM RAIL 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNEL NUT SS BONDING PINS NOTE: ·ALL HARDWARE IS INCLUDED FROM MANUFACTURER ·A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES ·GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ·GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL ·ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M : OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 320 W 40.29 V 33.46 V 9.89 A NOTES TO INSTALLER: ADD 25 AMP PV BREAKER TO MAIN PANEL. ELECTRICAL CALCULATIONS SIGNAGE & PLACARDS NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 16.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2019 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SITE PLAN PLACARDS WILL BE PROVIDED WITH INDIVIDUAL LOT SOLAR PLAN SET NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 15.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2019 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SITE PLAN PLACARDS WILL BE PROVIDED WITH INDIVIDUAL LOT SOLAR PLAN SET C C ADDITIONAL NOTES AND SPECIFICATIONS: ·PV JUNCTION BOX TO BE LOCATED ON ROOF. ALL WIRING FROM THE JUNCTION BOX TO THE COMBINER PANEL TO BE CONCEALED IN THE ATTIC / WALLS (WILL NOT BE LOCATED IN WET LOCATION OR SUBJECT TO PHYSICAL DAMAGE.) ·NEW 125A COMBINER PANEL TO BE INSTALLED INSIDE GARAGE. ADDITIONAL NOTES AND SPECIFICATIONS: ·PV JUNCTION BOX TO BE LOCATED ON ROOF. ALL WIRING FROM THE JUNCTION BOX TO THE COMBINER PANEL TO BE CONCEALED IN THE ATTIC / WALLS (WILL NOT BE LOCATED IN WET LOCATION OR SUBJECT TO PHYSICAL DAMAGE.) ·NEW 125A COMBINER PANEL TO BE INSTALLED INSIDE GARAGE. C CC C 07/20/2021 NEW 200A MAIN BREAKER (END FED) FACILITY GROUND(N) 30A PV BREAKER AT OPPOSITE END OF BUSBAR M METER #: PGE TBD 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID NEW 200A MAIN PANELFACILITY LOADS 20A BREAKER [A] 20A BREAKER [B] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C JUNCTION BOX OR EQUIVALENT 123 (17) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M MODULES AND MICRO-INVERTER PAIRS (17) ENPHASE ENERGY: IQ7PLUS-72-2-US -- (1) BRANCH OF (8) MICRO-INVERTERS [A] (1)BRANCH OF (9) MICRO-INVERTERS [B] CONDUIT SCHEDULE 1 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 CONDUIT SCHEDULE 2 #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 10 AWG THHN/THWN 2 ROMEX/NM-B (4) 10 AWG THHN/THWN-2 NONE (2) 8 AWG THHN/THWN-2 3 ROMEX/NM-B (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 17 MOD ELECTRICAL SYSTEM PV-4.1 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 ELECTRICAL DIAGRAM - 17 MODULE SYSTEM RAIL 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNEL NUT SS BONDING PINS NOTE: ·ALL HARDWARE IS INCLUDED FROM MANUFACTURER ·A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES ·GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ·GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL ·ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR4-60HPB-350M : OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 320 W 40.29 V 33.46 V 9.89 A NOTES TO INSTALLER: ADD 30 AMP PV BREAKER TO MAIN PANEL. ELECTRICAL CALCULATIONS SIGNAGE & PLACARDS NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 17.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2019 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SITE PLAN PLACARDS WILL BE PROVIDED WITH INDIVIDUAL LOT SOLAR PLAN SET C C ADDITIONAL NOTES AND SPECIFICATIONS: ·PV JUNCTION BOX TO BE LOCATED ON ROOF. ALL WIRING FROM THE JUNCTION BOX TO THE COMBINER PANEL TO BE CONCEALED IN THE ATTIC / WALLS (WILL NOT BE LOCATED IN WET LOCATION OR SUBJECT TO PHYSICAL DAMAGE.) ·NEW 125A COMBINER PANEL TO BE INSTALLED INSIDE GARAGE. CC 07/20/2021 SPEC SHEETS PV-5.0 CA CL #750184 PAGE REV: C 7/15/2021 3615 PATTON WAY, BAKERSFIELD, CA 93308 PHONE 661.340.2193 FAX TBD WOODBRIDGE PACIFIC GROUP 27271 LAS RAMBLAS, STE 100, MISSION VIEJO, CA 92691 COMMUNITY: PATINA SHEET DESIGNER: NICHOLAS LIVELY DEVELOPER: TEL. 949.348.8162 GILBERT CORREIA, C10, C46 C