Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BELC2019-0014
BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Electrical Permit Number: BELC2019-0014 Property Address: 79999 AVENUE 52 APN: 776150024 Legal Description Property Zoning: Valuation: $336,000.00 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 01/29/2019 ISSUED DATE: 03/22/2019 CALIFORNIA Owner: SILVERROCK DEVELOPMENT COMPANY LLC 343 FOURTH AVE, SAN DIEGO, CA 92101 Applicant: SILVERROCK DEVELOPMENT COMPANY LLC 343 FOURTH AVE, SAN DIEGO, CA 92101 Contractor: GRANITE CONSTRUCTION COMPANY P O BOX 50085 ATTN: LEGAL DEPT, WATSONVILLE, CA 95077-5085 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 6/5/25 9:36 am Page 1 of 4 BUILDING PERMIT Permit Type: Electrical Permit Number: BELC2019-0014 Property Address: 79999 AVENUE 52 construction lender preliminary notice from that duty. Printed: 6/5/25 9:36 am Page 2 of 4 BUILDING PERMIT Permit Type: Electrical Permit Number: BELC2019-0014 Property Address: 79999 AVENUE 52 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildinq official. Printed: 6/5/25 9:36 am Page 4 of 4 1091 Consulting Engineers, Inc. PROJECT: Silver Rock High Voltage Re -Route SUBMITTAL: UG HV Handholes Reviewed F Furnish as Corrected F Rejected F Submit Specific Item F Revised & Resubmit F Exceptions Noted Corrects or comments made on the shop drawings during this review do not relieve contractor from compliance with the requirements of the construction documents. This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Submitting contractor is responsible for: correlating and confirming dimensions at the job site; choice of fabrication processes and techniques for construction: coordination of his work with that of other trades; and performing the work in a safe and satisfactory manner. RB Consulting Engineers, Inc. Date: 1/31/19 By: Ken Bertalan Comments: Approved 1044 Pioneer Way, Suite E, El Cajon, CA 92020 Telephone: 619.599.6973 Email: kbertalan@rbcengineers.com GRAIIITE" To: WE ARE SENDING YOU ❑ Shop Drawings ❑ Copy of Letter I] Submittals ❑ Change Order Number Southern California Region Indio Area Office 38000 Monroe St. Indio, CA 92203 Phone (760) 775-7500 Fax (760) 775-8229 Suhmittal # 2 Date: January 24, 2019 Granite lob # SilverRock 12kv high voltage relocate City Project # Attn: Re: Submittal 3-Intercept Pullbox p Attached ❑ Under Separate Cover via the following items: ❑ Prints ❑ Plans ❑ Samples ❑ Contract ❑ Subcontracts ❑ Invoices(s) ❑ Payroll Docs ❑ Certificate(s) of Insurance Copies Section -Page Description 1 Sheet E7.01 Oldcastle Intercept Pullbox Tx 5' x 42" ❑ Specifications THESE ARE TRANSMITTED AS CHECKED BELOW: I] For Approval ❑ Approved as Submitted ❑ Resubmit _ Copies for Approval ❑ For Your Use ❑ Approved as Noted ❑ Submit _ Copies For Distribution ❑ As Requested ❑ Returned for Corrections ❑ Return _ Corrected Prints ❑ For Review and Comment ❑ ❑ For Bid Due By The ❑ Prints Returned After Loan To Us REMARKS: Attached please find product data for the Oldcastle Hand Hole Pull Boxes shown in detail 3/E7.01. Copy To: Job File Signed: Michael Taber IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE. 2 IUN U8 52 LIFTING ANCHORS 4 IN BODY 4 IN BASE SLAB 8 TOTAL 2 - 1"0 GROUND ROD KNOCKOUTS PLAN VIEW STRUCTURAL NOTES: DESIGN SPECIFICATIONS - AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES" - ACI-318_99 BUILDING CODE - ASTM C 857 MINIMUM STRUCTURAL DESIGN LOADING FOR UNDERGROUND PRECAST CONCRETE UTILITY STRUCTURES MATERIALS: - CONCRETE - 28 DAY COMPRESSIVE STRENGTH f'C = 4500 PSI - REBAR - ASTM A 706 GRADE 60 LOADS: - H2O WHEEL LOADS - 150 PCF CONCRETE DENSITY; 120 PCF SOIL DENSITY - H2O SURCHARGE: 80 PSF TO 8 FT BELOW GRADE - DRY SOIL LATERAL LOAD - 36 PCF - WET SOIL LATERAL LOAD - 80 PCF - WATER TABLE - 3' BELOW GRADE GENERAL NOTES: 1)CONTRACTOR TO: - GROUT ALL JOINTS AS REQUIRED 2)REBAR MAY BE TACK WELDED OR TIED �1/2"0 i-5000 PLASTIC INSERT 4 EA. SIDE 8 TOTAL "' I - u u u I I II L_ A II f� L_ A SECTION B-B APPROVED 0 TO BUILD RY• C.O. DATE: 10 24 11 4 - 10" X 16" KNOCKOUTS REF. DWGS.: SEE NOTE 2 EA. SIDE PREY. APPROVAL- 2/3/07 Tf LJ u SEE DRAWING NO. C17-4D8 FOR REINFORCING DETAILS CATALOG NAME EDISON 35481P KL 3'-0" X V-0" X 42" INTERCEPT PULL BOX 2 TON DB 52- 2 - 7/8" GALV. PULL IRONS UFUNG ANCHORS DRAWN H K xx DATE 5CALE 11-9-98 1 =1 -0 STANDARD PRODUCT UGS #225 SECTION A —A — — 1 SALESPERSON xx ITCMY T!1(1l11 SS wwh�I I�7 IPAGE 2 OF 2 2t-itw IUT wwu SOUTHERN CAUFORNIA EDISON ITCMI Y Dwhnl Ir•T v I ITCIIA- �. slle Precast, Inc. PRODVCT x 2ODUCT x s.o.� xxxx G NO C19-41 4-2 ©IdCastte Precast .d°/ Ln° brP2/ P Uremmm 51 PLAN VIEW PRODUCTION 1'-B' TVP f � OJLI }' TAPER TYP 6'-4• @ BOTTOM KEY VIEW A PRODUCTION I :rl S, 0 BOTTOM KEY �L VIEW B PRODUCTION CLR PLAN VIEW REINFORCEMENT VIEW A REINFORCEMENT VIEW B REINFORCEMENT STRUCTURALNOTES DESIGN SPECIFICATIONS. 1. ACI 3M BUILDING CODE REOUIREMENTS FOR STRUCTIAiAL CONCRETE 2 AASHTOSTANDAROSPECIRCATIONSFORHIGHWAYBRDGES 3. ASTM C857STANDARD PRACTICE FOR MINIMUM STRUCTURAL DESIGN LOADING FOR UNDERGROUND PRECAST CONCRETE UTILITY STRUCTURES MATERIALS'. 1. CONCRLTE26DAYSTRENGTH,fB=6,ODDPSI 2. CONCRETE STRIPPINGSTRENGTH,fd=1,50DPSIMI 3. RBEAR ASTMA706GRADE60 DESIGN CRITERIA: 1. LIVE LOAD= HIS 2) (INDIRECT) OR PARKWAY 3D0(PSIB 2. HS 20 SURCHARGE-80PSFT08FTBELOWGRADE 3. CONCRETEDENSITY=I5DPCF 4. SOIL DENSITY =120 PCF s. DRYSOIL IATERALLOAD=36FCF S. SATURATED SOIL LATERAL LOAD=80 PCF 7. WATER TABLE DEPTH• 3FT BELOWCHADE GENERAL NOTES: L 0 NTRACTORSHALL: ,1 GROUT AND/OR SEAL ALL AOINTSAS REQUIRED VERIFYALL DIMENSIONS AND OPENINGLOCATIONS 2. DO NOT BACKFILL UNTIL STRUCTURE HAS BEEN COMPLETELY ASSEMBLED PRODUCTION NOTES' 1. TOLERANCES ARE PER ASTM C858 2 A706 REBAR MAY BE TACK WELDED. ANY DEBAR THAT INTERSECTS ANOTHER BAR WITHIN 2 BAR DIAMETERS OFA BEND MUST BE TIED AND SHALL NOT BE TACK WELDED. 3. COILAND FERRULE INSERTS SHALL BE RECESSEDYK• MIN UNLESS NOTED OTHERWISE 4. TRIM REINFORCEMENT AROUND OPEMNGS T005'CLEAR UNLESS NOTED OTHERWISE THIS DWG REPLACES 3506 TX TOP ON DWG LTR I REVISION DAIL 2 SEE C14-208 ,NOTE I A DRAWN IN CAD 378 00 JMH -5� 3 1 2 TRAFFIC COVER MAY BE SFECWL B REVISED NOTES 3/27 02 CRO - VI ORDERED WITH PICK HOLES TO -"� B REPLACE HANDLES AT SAME LOCATION C NEW BORDER MITERED ANGLES &ADJUSTED DIMS. 12 11D6 GTA C 0 CHANGED TRAFFIC COVER ANGLE LENGTHS 2/7:07 GTA - �� r E ADD DRAIN HOLE DETAILS- r--3 2 F REMOVED BEAM DETAIL:SEE AUBURN FRAMES 010-SO60595-00 5/16'08 JER C I III l III _ III 45' MITER EA. END G EVISED PLATE NOTE IN BILL OF MATERIALS NEW TITLEBLOCK 30 O8 KILC III ( I A H DDED ONE ADDITIONAL 3 ANGLE IN RIGHT SIDE PKWY COVER 0/15'09 H III I I IT I DDED COVER LIP DETAIL 5 1/16� 10 R I I I J EVISED MI,E.'2 CUT TO ANGLE PART NO. 5& 7 •11/11 Ci C �YOJED NOTE FOR SPECIAL TRAFF�ICY" COVER Y. '2�Y5." 14 K-0 L DDED NOTE FOR PARKWAY COVER PLATE 30 15 JIM II III I II1 Y•0 HOLE HOLE -A"O HOLE Tit= 1 - D IF pZ--� I II II 1b II III �J T II II B III III °�' _ DRAIN HOLE DETAIL. 1 DRAIN HOLE DETAIL 2 DRAIN HOLE DETAIL 3 L-----ve mmm� E_==I =—A.1- N.T.S. N.T.S. N.T.S. A — —------- A \ (TRAFFIC COVER: PART No. ]) (TRAFFIC COVER: PART No. 6) (TRAFFIC COVER: PART No. 5) �-0 77 7/16• GAP 6 H- 2'-7 5'-3f6" B `t'7 H2O TRAFFIC COVER PLAN VIEW ELEVATION B—B DRAIN HOLE. DETAI 4 `A•m HOLE N.T.S (TRAFFIC COVER: PART No. 3) 2 - 2• \ (2 REQUIRED) EOU RED) NOTES: o o .7q• 2_6 — FOR TRAFFIC APPLICATIONS THE L REMOVABLE BEAM & ALL COVER FOR FRAME & BEAM REFER TO -- ---- --- — BOLTS MUST BE IN PLACE AND AUBURN FRAMES 010—S060595-002 lei PROPERLY SECURED AT ALL TIMES. SHEETS 5, 6 AND 7 — REFER TO C14-208 FOR DETAILS ELEVATION A —A COVERS SCHEDULE 0 APPROVED TO BUILD BY, DG DATE, 6 30 15 REF. ➢WGS.. SEE NOTE PREY. APPROVAL. 7/25/14 THIS DOCUMENT IS THE PROPERTY OF OLDCASTLE PRECAST, INC. IT IS SUBMITTED FOR REFERENCE PURPOSES ONLY AND SHALL NOT BE USED IN ANY WAY INJURIOUS TO THE INTERESTS OF SAID COMPANY. COPYRIGHT ©20,1 Oldcoslle Precast, Inc. All Rights Reserved 3'-0• X 5'-0" 1 TRAFFIC COVERS STANDARD PRODUCT OLDCASTLE NO.C14-209 0 Oldcastle Precast (em) ers �xeo ro. �o�) sso�esia Consulting Engineers, Inc. PROJECT: Silver Rock High Voltage Re -Route SUBMITTAL: Medium Voltage Cable r Reviewed F Furnish as Corrected F Rejected r Submit Specific Item F Revised & Resubmit F Exceptions Noted Corrects or comments made on the shop drawings during this review do not relieve contractor from compliance with the requirements of the construction documents. This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Submitting contractor is responsible for: correlating and confirming dimensions at the job site; choice of fabrication processes and techniques for construction: coordination of his work with that of other trades; and performing the work in a safe and satisfactory manner. RB Consulting Engineers, Inc. Date: 3/13/19 By: Ken Bertalan Comments: Approved 1044 Pioneer Way, Suite E, El Cajon, CA 92020 Telephone: 619.599.6973 Email: kbertalan@rbcengineers.com G GRAI'11TE' To: John Gamlin WE ARE SENDING YOU ❑ Shop Drawings ❑ Copy of Letter [21 Submittals ❑ Change Order Number Southern California Region Indio Area Office 38000 Monroe St. Indio, CA 92203 Phone (760) 775-7500 Fax (760) 775-8229 Submittal # 9 Date: Granite Job # Project # Attn: Re: March 13, 2019 SilverRock 12kv Reclocate John Gamlin Submittal #01- Wire/Splice/Elbow/Joint p Attached ❑ Under Separate Cover via the following items: ❑ Prints RI Plans ❑ Samples ❑ Specifications ❑ Contract ❑ Subcontracts ❑ Invoices(s) ❑ Payroll Docs ❑ Certificate(s) of Insurance Copies Section -Page Description 1 E1.0,E1.1,E7.02,E8.01 Wire/Splice/Elbow/Joint THESE ARE TRANSMITTED AS CHECKED BELOW: [21 For Approval ❑ Approved as Submitted ❑ Resubmit _ Copies for Approval ❑ For Your Use ❑ Approved as Noted ❑ Submit _ Copies For Distribution ❑ As Requested ❑ Returned for Corrections ❑ Return _ Corrected Prints ❑ For Review and Comment ❑ ❑ For Bid Due By The ❑ Prints Returned After Loan To Us REMARKS: Attached please find the wire/splice/joint/elbow submittal for the above refrenced project. Copy To: Job File Signed: Michael Taber IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE. Drawing / Data Sheet Conductor EmYowrUR Link a4RAINI)V1LL9 Concentric Aeutral (Round Wire) Yower Cable 17kV E F D 0 not to scale Thickness (inches) Diameter (inches) Component Description Min. Nom.* Max. Min. Nom.* Max. A: Conductor: 3/4 To Hard -- -- 0.355 0.362 0.369 1/0 AWG Class B Compressed Stranded Filled AL Conductor B: Conductor Shield 0.012 0.018 0.398 Semiconducting Thermoset Polymer C: Insulation Insulation Level 0.210 0.220 0.250 0.805 0.838 0.895 Tree Retardant Crosslinked Polyethylene 133% D: Insulation Shield 0.030 0.035 0.060 0.865 0.908 0.995 Semiconducting Thermoset Polymer E: Concentric Neutral / Metallic Shield -- -- -- -- 1.024 -- 16 x 14 AWG Bare Copper Round Wire F: Jacket 0.045 0.055 0.080 1.134 EXTRUDED -TO -FILL Linear Low Density Polyethylene Single Conductor Finished Cable Nominal Weight: 504 lb/kft Single Conductor Finished Cable Nominal Overall Diameter: 1.134 inches * - Nominal Values are Subject to Manufacturing Tolerances; Bold Font Indicates Minimum Average Values Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: --,j592-00105 159405.2500 Rev. 2 Specification / MS 477 Date: 9/23/2008 AEIC CS8-13, ICEA S-94-649 Prepared By: Date: Standard: HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Document No: MVUG Datasheet Tel: 859-572-8000 www.generalcable.com Q General Cable EmPowr° -r Electrical Characteristics Single Conductor EmPowr@ Link STRANDFILL@ Concentric Neutral (Round Wire) Power Cable 17kV Cable Description: 1/0 AWG Al, 0.220" TRXLPE,16 x #14 AWG Cu, LLDPE Electrical Characteristics Based on Normal Operating Temperature: 90 °C Dissipation Factor: 0.01 % S S Input Parameters: IR Constant @ WE: 20000 Voltage (line to ground): 9.81 kV Dielectric Constant: 2.35 Conductor Center to Center Spacing (S): 7.5 in Earth Resistivity: 100 n-m 2S Flat Arrangement Rdc @ 25°C: 0.1670 n/kft 0.5479 0/km Conductor Resistance: Rae @ 25°C: 0.1671 n/kft 0.5481 n/km Rae @ 90°C: 0.2101 n/kft 0.6894 SUkm Rae @ 25°C: 0.170 n/kft 0.559 n/km Shield Resistance: Rae @ 85°C: 0.210 n/kft 0.689 n/km Capacitance: 0.053 µF/kft 0.175 µFlan Shunt Capacitive Shunt Capacitive Reactance: 49592 n-kft 15115 n-km Reactance/Susceptance: Shunt Capacitive Susceptance: 20.16 µS/kft 66.16 VS/km Charging Current: 197.8 mA/kft 649.0 mA/km Inductive Reactance: 0.029 n/kft 0.095 6Ulmi Single Phase Real Imag. Impedance Real Imag. Impedance Reactance/Impedance: Pos. & Neg. Seq. Impedance (Met. Shield): 0.210 0.029 0.212 n/kft 0.689 0.095 0.696 DArn Zero Seq. Impedance (Earth & Met. Shield): 0.583 0.317 0.664 n/kft 1.914 1.038 2.177 Dian Inductive Reactance: 0.097 n/kft 0.319 0Jkm 3-Phase Real Imag. Impedance Real Imag. Impedance Pos. & Neg. Seq. Impedance (Met. Shield): 0.230 0.091 0.247 n/kft 0.755 0.298 0.812 DArn Reactance/Impedance: Zero Seq. Impedance (Earth & Met. Shield): 0.395 0.088 0.405 n/kft 1.297 0.290 1.329 DArn Zero Seq. Impedance (Earth Only): 0.264 0.661 0.712 n/kft 0.867 2.169 2.336 Dian Zero Seq. Impedance (Met. Shield Only): 0.420 0.029 0.421 n/kft 1.378 0.095 1.381 Dian Dielectric Losses: 0.19 W/kft 0.63 W/km (Per Phase) Insulation Average: 44.59 V/mil 1.76 kV/= Electrical Stress: Conductor Shield - Insulation Interface Maximum: 66.16 V/mil 2.60 kV/= Insulation - Insulation Shield Interface Minimum: 31.42 V/mil 1.24 kV/mm Insulation Resistance: 6467.22 Mn-kft 1971.11 Mn-km Velocity of Propagation 492.39 ft/ps 150.08 m/µs Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: 592-00105 159405.2500 Rev. 2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, ICEA 5-94-649 Prepared by: Date: HQQUHZB 3/9/2016 Dimensions and weights not designated miuhnum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Tel: 859-572-8000 Document No: MVUG Datasheet wwva.general cable. com Q General Cable EmPowr -ooi� _. Electrical Characteristics Single Conductor EmPowr@ Link STRANDFILL@ Concentric Neutral (Round Wire) Power Cable 17kV Cable Description: 1/0 AWG Al, 0.220" TRXLPE,16 x #14 AWG Cu, LLDPE s s Electrical Characteristics Based on Normal Operating Temperature: 90 °C Dissipation Factor: 0.01 % Input Parameters: IR Constant @ WE: 20000 Voltage (line to ground): 9.81 kV Dielectric Constant: 2.35 Conductor Center to Center Spacing (S): 1.1342 in 2s Earth Resistivity: 100 n-m Flat Adjacent Arrangement Rdc @ 25°C: 0.1670 n/kft 0.5479 0/km Conductor Resistance: Rae @ 25°C: 0.1671 n/kft 0.5481 n/km Rae @ 90°C: 0.2101 n/kft 0.6894 SUkm Rae @ 25°C: 0.170 n/kft 0.559 n/km Shield Resistance: Rae @ 85°C: 0.210 n/kft 0.689 n/km Capacitance: 0.053 µF/kft 0.175 µFlan Shunt Capacitive Shunt Capacitive Reactance: 49592 n-kft 15115 n-km Reactance/Susceptance: Shunt Capacitive Susceptance: 20.16 µS/kft 66.16 VS/km Charging Current: 197.8 mA/kft 649.0 mA/km Inductive Reactance: 0.029 n/kft 0.095 6Ulmi Single Phase Real Imag. Impedance Real Imag. Impedance Reactance/Impedance: Pos. & Neg. Seq. Impedance (Met. Shield): 0.210 0.029 0.212 n/kft 0.689 0.095 0.696 DArn Zero Seq. Impedance (Earth & Met. Shield): 0.583 0.317 0.664 n/kft 1.914 1.038 2.177 Dian Inductive Reactance: 0.054 n/kft 0.177 n/km 3-Phase Real Imag. Impedance Real Imag. Impedance Pos. & Neg. Seq. Impedance (Met. Shield): 0.213 0.054 0.220 n/kft 0.699 0.176 0.721 DArn Reactance/Impedance: Zero Seq. Impedance (Earth & Met. Shield): 0.400 0.083 0.409 n/kft 1.313 0.272 1.341 DArn Zero Seq. Impedance (Earth Only): 0.264 0.748 0.793 n/kft 0.867 2.454 2.602 Dian Zero Seq. Impedance (Met. Shield Only): 0.420 0.029 0.421 n/kft 1.378 0.095 1.381 Dian Dielectric Losses: 0.19 W/kft 0.63 W/km (Per Phase) Insulation Average: 44.59 V/mil 1.76 kV/= Electrical Stress: Conductor Shield - Insulation Interface Maximum: 66.16 V/mil 2.60 kV/= Insulation - Insulation Shield Interface Minimum: 31.42 V/mil 1.24 kV/mm Insulation Resistance: 6467.22 Mn-kft 1971.11 Mn-km Velocity of Propagation 492.39 ft/ps 150.08 m/µs Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: 592-00105 159405.2500 Rev. 2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, ICEA 5-94-649 Prepared by: Date: HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Tel: 859-572-8000 Document No: MVUG Datasheet wwva.general cable. com Q General Cable EmPowr rLMMI&A Electrical Characteristics Single Conductor EmPowr@ Link STRANDFILL@ Concentric Neutral (Round Wire) Power Cable 17kV Cable Description: 1/0 AWG Al, 0.220" TRXLPE,16 x #14 AWG Cu, LLDPE Electrical Characteristics Based on Normal Operating Temperature: 90 °C Dissipation Factor: 0.01 % Input Parameters: IR Constant @ 60°F: 20000 Voltage (line to ground): 9.81 kV Dielectric Constant: 2.35 Conductor Center to Center Spacing (S): 1.1342 in S Earth Resistivity: 100 n0-ange t Arrange ment Rdc @ 25°C: 0.1670 n/kft 0.5479 0/km Conductor Resistance: Rae @ 25°C: 0.1671 n/kft 0.5481 n/km Rae @ 90°C: 0.2101 n/kft 0.6894 SUkm Rae @ 25°C: 0.170 n/kft 0.559 n/km Shield Resistance: Rae @ 85°C: 0.210 n/kft 0.689 n/km Capacitance: 0.053 µF/kft 0.175 µFlan Shunt Capacitive Shunt Capacitive Reactance: 49592 n-kft 15115 n-km Reactance/Susceptance: Shunt Capacitive Susceptance: 20.16 µS/kft 66.16 VS/km Charging Current: 197.8 mA/kft 649.0 mA/km Inductive Reactance: 0.029 n/kft 0.095 6Ulmi Single Phase Real Imag. Impedance Real Imag. Impedance Reactance/Impedance: Pos. & Neg. Seq. Impedance (Met. Shield): 0.210 0.029 0.212 n/kft 0.689 0.095 0.696 DArn Zero Seq. Impedance (Earth & Met. Shield): 0.583 0.317 0.664 n/kft 1.914 1.038 2.177 Dian Inductive Reactance: 0.049 n/kft 0.159 a/km 3-Phase Real Imag. Impedance Real Imag. Impedance Pos. & Neg. Seq. Impedance (Met. Shield): 0.212 0.048 0.217 n/kft 0.695 0.159 0.713 DArn Reactance/Impedance: Zero Seq. Impedance (Earth & Met. Shield): 0.401 0.082 0.409 n/kft 1.315 0.270 1.342 DArn Zero Seq. Impedance (Earth Only): 0.264 0.758 0.803 n/kft 0.867 2.488 2.635 Dian Zero Seq. Impedance (Met. Shield Only): 0.420 0.029 0.421 n/kft 1.378 0.095 1.381 Dian Dielectric Losses: 0.19 W/kft 0.63 W/km (Per Phase) Insulation Average: 44.59 V/mil 1.76 kV/= Electrical Stress: Conductor Shield - Insulation Interface Maximum: 66.16 V/mil 2.60 kV/= Insulation - Insulation Shield Interface Minimum: 31.42 V/mil 1.24 kV/mm Insulation Resistance: 6467.22 Mn-kft 1971.11 Mn-km Velocity of Propagation 492.39 ft/ps 150.08 m/µs Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: 592-00105 159405.2500 Rev. 2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, ICEA 5-94-649 Prepared by: Date: HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Tel: 859-572-8000 Document No: MVUG Datasheet wwva.general cable. com a C 0 u d Ul C d F General Cable ffflP0 10 im 0.1 0.01 4— 1,000 Conductor Fault Current 1/0 AWG Al, 0.220" TRXLPE, 16 x #14 AWG Cu, LLDPE MAXIMUM FAULT CURRENT OPERATING LIMITS FOR AN 1/0 INSULATED ALUMINUM CONDUCTOR AT 60 Hz 10,000 Current in amps 1/0 Insulated Aluminum Conductor Number of Cycles Time (s) Current (amps) 8 0.13 13600 16 0.27 9620 24 0.40 7850 24 cycles (7850 amps) 16 cycles (9620 amps) 8 cycles (13600 amps) 100,000 Notes - The calculations areas per ICEA P-32-382. The calculations assume that all heat generated remains in the metal. The duration of a Short circuit is considered to be up to approximately 2 seconds. The indicated short circuit value shown on this graph for durations longer than 2 seconds should be used with caution. The time shown is calculated for a given RMS fault current to bring the conductor to a temperature that will not cause damage to the conductor shield or the insulation. The calculations are based on a cross -sectional area of 105600 cmil of Aluminum starting at an initial temperature of 90 C, and a final temperature of 250 C. The calculations utilize an absolute temperature of resisitvity of 228 and an ICEA calculation factor of 0.0125 The system frequency is 60 Hz Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: 592-00105 159405.2500 Rev. 2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, Prepared by: � Date: EMEL ICEA S-94-649 HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Document No: MVUG Datasheet Tel: 859-572-8000 w .generalcable.com WK QGenera�le IMPOWCO Shield Fault Current 1/0 AWG Al, 0.220" TRXLPE, 16 x #14 AWG Cu, LLDPE MAXIMUM FAULT CURRENT OPERATING LIMITS FOR A 65760 cmil COPPER METALLIC SHIELD AT 60 Hz 10 1 w v c 0 u m m E 0.1 0.01 100 24 cycles (6550 amps ) 16 cycles (8020 amps) 8 cycles (11300 amps) 1,000 10,000 100,000 1,000,000 Current in amps 16 x #14AWG Copper Concentric Neutral Number of Cycles Time (s) Current (amps) 8 0.13 11300 16 0.27 8020 24 0.40 6550 Notes - The curves assume that all heat generated remains in the metal. The time shown is that calculated for a given RMS fault current to bring the metallic shield to a temperature that will not cause damage to the insulation shield or cable jacket. The calculations are as per ICEA P-45-482 using an "M factor" of 0.063 corresponding to a 5-15 kV rated cable, with a conductor temperature of 90 and a metallic shield starting temperature of 85 C and a metallic shield ending temperature of 200 Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: * EA/PC Number: 592-00105 159405.2500 Rev. 2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, Prepared by: Date: � = ICEA S-94-649 HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. Utility Engineering Center Document No: MVUG Datasheet Tel: 859-572-8000 w .generalcable.com General Cable EmNwr-, Cable Installation Single Conductor EmPowr® Link STRANDFILL® Concentric Neutral (Round Wire) Power Cable 17kV Cable Description: 1/0 AWG Al, 0.220" TRXLPE, 16 x #14 AWG Cu, LLDPE Single Conductor 3x1/C Parallel Conductor Pulling Eye / Bolt: 840 lb 3.7 kN 1680 lb 7.5 kN Maximum Pulling Cable Basket Grip: 1160 lb 5.2 kN 2320 lb 10.3 kN 3 grips, t per cable Tension: NOTE: When exceeding 100 lb pulling force, proceed with caution. Pulling grips must be sized in accordance with grip manufacturer's recommendations and be installed in accordance with AEIC CG5-05 Maximum Sidewall Bearing Pressure: Radius for Permanent Training Conduit (Schedule 40) Information: 2000 lb/foot of bend radius NOTE: When exceeding 1000 lb/SWBP, proceed with caution NEC Applications: 12 x O.D. 14 inches Non -NEC Applications: 8 x O.D. 9 inches 29 kN/meter of bend radius 356 mm 229 mm Single Conductor Conduit Dimensions Metric Size (mm) Imperial Size (in.) ID % Fill Jam Ratio Clearance (in.) (mm) (in.) I (mm) 41 1'/z 1.61 40.89 50 N/A 0.476 12.09 35 P/4 1.38 35.05 68 N/A 0.246 6.24 3x1/C Parallel Conduit Dimensions Metric Size (mm) Imperial Size (in.) ID % Fill Jam Ratio Clearance (in.) (mm) (in.) (mm) 91 3'h 3.548 1 90.12 31 3.28 1.881 47.77 78 3 3.068 1 77.93 41 2.84 1.269 32.22 *Jam Ratio between 2.8 and 3.2; Jamming Probable **Jam Ratio between 2.5 and 2.8; Jamming Possible Customer: SOUTHERN CALIFORNIA EDISON Customer P/N: EA/PC Number: 592-00105 159405.2500 Rev.2 Specification / Standard: MS 477 Date: 9/23/2008 AEIC CS8-13, ICEA S-94-649 Prepared by: Date: HQQUHZB 3/9/2016 Dimensions and weights not designated minimum or maximum are nominal and subject to manufacturing tolerances. The information contained in this document is the exclusive and proprietary intellectual property of General Cable Corporation, and any reproduction or disclosure, in whole or in part, is prohibited without the express written consent of an officer of General Cable Corporation. ©General Cable Corporation 2015, all rights reserved. Utility Engineering Center Tel: 859-572-8000 Document No: MVUG Datasheet www.generaicable.com XHHW-2 Product Description Solid or stranded XLP insulation/jacket 90°C wet/dry 600 V Applications General purpose wiring for control, switchboard, lighting and power circuits in residential and commercial buildings and industrial plants, and for utility substations, meters and generating plants. Specifications — CONDUCTOR: Class B stranded, annealed, bare copper — INSULATION: Cross -Linked Polyethylene (XLP) — STANDARDS: Listed Type XHHW-2 per UL 44 Thermoset -Insulated Wires and Cables, meets construction requirements of ICEA S-95-658 (NEMA WC 70), conforms to Federal Specification A-A-59544 — AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per 2008 NEC Table 310.16 — TEMPERATURE:90°C — VOLTAGE: 600 V Dectrical and Electronic Wre & Cable • Enterprise Cabling & Security Solutions • Fasteners Anixter Inc. World Headquarters • 2301 Patriot Boulevard, Glenview, IL 60026-8020.1.800.ANIXrER • 224.521.8000 • anixter.00m Arrxter is a leadi rig global supplier of corrrrunicadiors and security products, electrical and decrrorrc Wre and cable, fasteners and other small components. We help ar customers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. ThraMhout the vwdd, vie provide innovative supply chain management solutions to reduce o r oustarers total oust of production and implementation. Minter does nut manufacture the items described in this publication. My applicable product"amanties are provided try the manufacturers. Tote fullest extern permitted bylaw, Minter disdairrs all "amanties, either excess or irroied. The information provided and any images shone are for descriptive purposes oriy. Minter rakes no warmly or representation, egxess or implied, about the accuracy or corroeterress of arry information prodded. Data and suggestions made in the publication are rot to be construed as recormer labors to purchase or as aut honzabons to use any products in violation of any lave or regulation. Al products are sold subbed to Millers General Conditiors of Sale. Unless otherwise specifically permitted in the NEC, the overcurrent protection shall not exceed 15 A for 14 AWG, 20 A for 12 AWG and 30 A for 10 AWG copper. Diameters and weights may vary among manufacturers.CT rated material available in sizes 1/0 and larger. Part No. Conductor Size No. of Strands Insulation Nom. O.D. (in.) Approx. Wt. Amps per AWG/kcmil Thickness (in.) Ib./1,000 ft. Conductor 6L-1401 14 Solid 0.030 0.130 17 25 6L-1201 12 Solid 0.030 0.150 26 30 6L-1001 10 Solid 0.030 0.170 38 40 6M-1401 14 7 0.030 0.140 18 25 6M-1201 12 7 0.030 0.160 27 30 6M-1001 10 7 0.030 0.180 40 40 6M-0801 8 7 0.045 0.240 66 55 6M-0601 6 7 0.045 0.280 96 75 6M-0401 4 7 0.045 0.320 145 95 6M-0201 2 7 0.045 0.380 225 130 6M-0101 1 7 0.055 0.440 290 150 6M-1011 1/0 19 0.055 0.480 360 170 6M-2021 2/0 19 0.055 0.520 450 195 6M-3031 3/0 19 0.055 0.580 555 225 6M-4041 4/0 19 0.055 0.630 700 260 6M-2501 250 37 0.065 0.700 830 290 6M-3001 300 37 0.065 0.750 990 320 6M-3501 350 37 0.065 0.800 1,150 350 6M-4001 400 37 0.065 0.850 1,310 380 6M-5001 500 37 0.065 0.930 1,620 430 6M-7501 750 61 0.080 1.040 2,445 535 6M-10001 1000 61 0.080 1.290 3,240 615 Dectrical and Electronic Me & Cable • Enterprise Cabling & Security Solutions • Fasteners Pnixter Inc. World Headquarters • 2301 Patriot Boulevard, Glenview, IL 60026-8020.1.800MIXfER • 224.521.8000 • anixter.00m Arrxter is a leadi rig global supplier of omrrunicadiors and security products, electrical and decrrorrc Wre and cable, fasteners and other small components. VVe help ar custowers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. Thratghout the vwdd, vie provide innovative supply chain management solutions to reduce o r oustarers total oust of production and implementation. Minter does nut manufacture the items described in this publication. My applicable product"amanties are provided try the manufacturers. Tote fullest e>dent permitted bylaw, Minter disdairrs all "amanties, either excess or irroied. The information provided and any images shone are for descriptive purposes oriy. Minter rakes no warmly or representation, egxess or implied, about the accuracy or corroeterress of arry information prodded. Data and suggestions made in the publication are rot to be construed as recormar labors to purchase or as aut honzabons to use any products in violation of any lave or regulation. Al products are sold subject to Millers General Gorditiors of Sale. 3MTM Cold Shrink Splice Kits 3MTM Cold Shrink Connector Insulators 8420 and 8430 Series 3MTM Cold Shrink Connector Insulators 8420 and 8430 Series are designed using 3M's proprietary cold shrink delivery system. Products are supplied prestretched on a removable core for efficiency and ease of installation. Removal of the core (unwinding) after positioning the splice allows the product to shrink into position forming a moisture -tight seal. The live memory action of the specially formulated EPDM material promotes a permanent, durable environmental seal and insulation, with a typical operating temperature range from-40-194OF (40-900C). The 8420 insulator meets requirements of ANSI C119-1 and Western Underground Guide 2.14 for secondary splices rated up to 1 kV. Important: Use insulation jacket or connector O.D. for final ordering criteria. " Mastic pads included for cable O.D. build-up. "" Kit contains adapters. ""' These sizes are listed for availability only and are not designed to be used as primary insulation. These tubes are for conduit sealing and breakouts. "'""Maximum connector length: 5.625" "Point of Purchase" packaging designated by "P". Example: 8423-6P Voltage 1000 V or less Number of Conductors Single Conductor Cable Type Low Voltage Single Conductor Insulated Cable Splice Type Cold Shrink Primary electrical insulation for all solid dielectric (rubber and plastic) insulated wire and cable splicing rated Applications to 1000 V. Good for repairs and envi- ronmental sealing for communication and other non -electrical applications. RoHS 2011/65/EU Yes Agency Approvals ANSI C1191.1 Single Conductor Cable Order No. UPC Typical Conductor Size Min. Cable D. Max. Dia. Insulator Cable or Connector Max. Connector Relaxed Tube Case for Seal Covers Length Length Qty. 8423-6 054007-42146 6-4AWG 0.31" (7,8 mm) 6.0" (152,4 mm) 10 0.56" (14,2 mm) 2.0" (50,8 mm) (14-16 mm2) 8423-6P 054007-42864 6-4AWG 0.31" (7,8 mm) 0.56" (14,2 mm) 2.0" (50,8 mm) 6.0" (152,4 mm) 10 (14-16 mm2) 8424-8"" 054007-42390 10-1/0 AWG 0.10" (2,5 mm) 0.82" (20,9 mm) 3.0" (76,2 mm) 8.0" (203,2 mm) 10 (6-16 mm2) 8424-8P 054007-42865 10-1/0AWG 0.10" (2,5 mm) 0.82" (20,9 mm) 3.0" (76,2 mm) 8.0" (203,2 mm) 10 (6-16 mm2) 8425-8 054007-42391 2-1/0AWG 0.40" (10,1 mm) 0.82" (20,9 mm) 3.0" (76,2 mm) 8.0" (203,2 mm) 10 (35-50 mm2) 8425-BP 054007-42866 2-1/0AWG 0.40" (10,1 mm) 0.82" (20,9 mm) 3.0" (76,2 mm) 8.0" (203,2 mm) 10 (35-50 mmz) 8426-9 054007-34457 2/0 AWG-250 kcmil 0.55" (13,9 mm) 1.18" (30,1 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 (70-125 mm2) 8426-9M" 054007-43436 2-4/0 AWG 0.40" (10,1 mm) 1.18" (30,1 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 (30-90 mm2) 8426-9P 054007-42867 2/0 AWG-250 kcmil 0.55" (13,9 mm) 1.18" (30,1 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 (70-125 mm2) 8426-11 054007-34458 2/0 AWG-250 kcmil 0.55" (13,9 mm) 1.18" (30,1 mm) 7.0" (177,8 mm) 11.0" (279,4 mm) 10 (70-125 mm2) 8427-6"' 054007-09915 - 0.67" (16,8 mm) 1.38" (35,1 mm) 2.0" (50,8 mm) 6.0" (152,4 mm) 10 8427-12 054007-34459 250-400 kcmil 0.67" (16,8 mm) 1.38" (35,1 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (125-200 mm2) 8427-12P 054007-42868 250-400 kcmil 0.67" (16,8 mm) 1.38" (35,1 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (125-200 mm2) 8427-16 054007-34460 250-400 kcmil 0.67" (16,8 mm) 1.38" (35,1 mm) 12.0" (304,8 mm) 16.0" (406,4 mm) 10 (125-200 mm2) 8428-6""' 054007-09916 - 0.95" (24,1 mm) 1.94" (49,2 mm) 2.0" (50,8 mm) 6.0" (152,4 mm) 10 PHONE: 800-245-3573 www.3M.com/Electrical 163 3MTM Cold Shrink Splice Kits 3MTM Cold Shrink Connector Insulators 8420 and 8430 Series (continued) No. UPC Typical Conductor Size Min. ,. CableOrder Max. D. Insulator Cable or Connector Max. Connector Relaxed Tube for Seal Covers Length Length Qty. 8428-6M 051128-53828 450-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 2.0" (50,8 mm) 6.0" (152,4 mm) 50 (240-400 mm2) 8428-8 051128-53711 500-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 3.0" (76,2 mm) 8.0" (203,2 mm) 25 (300-400 mm2) 8428-12 054007-09056 500-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (300-400 mm2) 8428-12M 054007-43746 500-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (300-400 mm2) 8428-12P 054007-42869 500-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (300-400 mm2) 8428-18 054007-34461 500-800 kcmil 0.95" (24,1 mm) 1.94" (49,2 mm) 14.0" (355,6 mm) 18.0" (457,2 mm) 10 (300-400 mm2) 8429-6*** 054007-09917 - 1.27" (32,2 mm) 2.67" (67,8 mm) 2.0" (50,8 mm) 6.0" (152,4 mm) 10 8429-9**** 054007-09931 900-1000 kcmil 1.27" (32,2 mm) 2.67" (67,8 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 (500 mm2) 8429-9M 054007-42018 900-1000 kcmil 1.27" (32,2 mm) 2.67" (67,8 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 (500 mm2) 8429-12 054007-42389 900-1000 kcmil 1.27" (32,2 mm) 2.67" (67,8 mm) 8.0" (203,2 mm) 12.0" (304,8 mm) 10 (500 mm2) 8429-15 054007-44198 900-1000 kcmil 1.27" (32,2 mm) 2.67" (67,8 mm) 11.0" (279,4 mm) 15.0" (381,0 mm) 10 (500 mm2) 8429-18 054007-34462 900-1000 kcmil 1.27" (32,2 mm) 2.67" (67,8 mm) 14.0" (355,6 mm) 18.0" (457,2 mm) 10 (500 mm2) 8430-9*** 054007-42147 1250-2000 kcmil 1.68" (42,6 mm) 3.69" (93,7 mm) 5.0" (127,0 mm) 9.0" (228,6 mm) 10 8430 18 054007-42388 1250-2000 kcmil 1.68" (42,6 mm) 3.69" (93,7 mm) 14.0" (355,6 mm) 118.0" (457,2 mm) 110 164 FAX: 800-245-0329 On Line Cat aloa BURNDY LLC - USA 47 East Industrial Park Drive Manchester NH 03109 BURNDY Catalog Number UPC Number Description Status Web Use BURNDY Product Line YS6C 7818105074077 BUTT SPLICE LONG 6 Active Dimensional Strip Length 1-3/16 Barrell Style Chamfered Barrel Type Long General Copper Compression Splice, 6 Product Description AWG, 2.38" Splice Length, Long Barrel, Tin Plated Physical Type of Plating Tin - Electro Plated Plated (Yes or No) Y Index Number 7,374 Product Material Copper Approvals / Certifications UL Listed Y CSA Certified Y ROHS Compatible Compliant UL Recognized N CULUS N Industry Standards UL468A-468B Documentation For further technical assistance, please contact us BURNDY Technical Services 47 East Industrial Park Drive Manchester NH 03109 Hours: 8:00 AM - 5:00 PM Monday - Friday Phone: 800-346-4175 Issue Date: Page: File: 09/24/2014 1 of 2 PSS-162LR-W5X 15kV 200A Loadbreak Elbow w/ Test Point 162LR-W5X Features: • 15kV, 200 Amp Loadbreak Elbow • Fully shielded, fully submersible molded rubber housing • 100% peroxide -cured construction includes insulation and conductive EPDM materials • Provision for hot stick operation • Provision for ground wire connection • Wide cable range with minimum number of sizes • Non -corrosive capacitive test point 162LR Loadbreak Elbow Connector Applications: The Elastimold® 162LR Elbow Connector is a fully rated 15kV, 200 Amp Class loadbreak connector. It includes provisions for energized operation using standard hotstick tools allowing load make/load break operation and a visible disconnect. It has a standard interface for connecting to 15kV, 200 Amp bushing inserts, junctions, and operating accessories. The 162LR is designed for connecting to and operating 15kV Class, 200 Amp distribution apparatus. It provides a convenient method to connect/disconnect cable and equipment on power distribution systems. The 162LR allows connection of cables with insulation diameters from .575" (14,6mm) to 1.220" (31,Omm) with only four elbow sizes. (#4 solid, 175 mil to 4/0 stranded, 260 mil) Ratings: Meets ANSI/IEEE Standard 386, Latest Revision For 15kV Voltage Class: 8.3kV Max Phase -to -Ground — Operating Voltage 14.4kV Max Phase -to -Phase 95kV BIL — Impulse Withstand (1.2 x 50 microsecond wave) 34kV AC — One minute withstand 53kV DC — 15 minutes withstand 11 kV AC — Corona Extinction @ 3pC sensitivity 200 Amp — Continuous and Loadbreak 10kA Sym — 10 Cycles Momentary & Fault Close 8155 T&B Boulevard, Memphis, TN 38125 www.tnb.com 901-252-5000.FAX 901-252-1331 Thomas o efts A Member of the ABB Group Issue Date: 09/24/2014 Page: 2 of 2 File: PSS-162LR-W5X 15kV 200A Loadbreak Elbow w/ Test Point 162LR-W5X CATALOG NUMBER SELECTION Step 1 (W) Determine the insulation diameter of the cable. Select the insulation letter code that best straddles the insulation diameter from W table below. Insert code into catalog number. Step 2 Insert conductor material code from the Material Code table. Code 5 is standard. Step 3 (X) Choose the proper compression lug code according to the conductor size from the Conductor Code Table. Insert code into catalog number. W Code 162LR - B Cable Insulation Diameter in Inches Cable Insulation Diameter in mm Symbol MIN. MAX. MIN. MAX. for W 0.575 0.740 14.61 18.80 A 0.635 0.905 16.13 22.99 B 0.805 1.060 20.45 26.92 C 0.890 1 1.220 1 22.61 30.99 D Example: The ordering number for an Elbow Connector for a 1/0 compressed/stranded, 220 mil wall cable with an insulation diameter of .805" to .895" and capacitive test point is 162LR- B5240. Each kit contains the following: 1 Elbow connector housing 162BLR-W 1 Bi-metal compression lug 0250OXXX 1 Probe 162LRF 1 Probe wrench 271-94 1 Tube, lubricant 82-08 1 Crimp chart CC-0020 1 V.D Cap -Peroxide 156-7 1 Installation Instruction IS-1378 Material Code ?29 a O o D�.A 3 Te i —L -- -- 95,5 1.25 - - — al.s I .I BUSHING DATUM ' 2 Copper" 5 Bi-metal" XXX Code 2.V Td,2 ATES WITH BUSHING INTERFACE THAT CONFORMS NITH ANSI STD 3e4 W o Conductor Size AWG or kcmil Connector only U X x Strand./ Compr. Solid/ Comp. mm2 BI- Metal Copper 190 - #4 16.76 02500190 027002190 200 #4 #3 21.14 02500200 02702200 210 #3 #2 26.67 02500210 02702210 220 #2 41 33.62 02500220 02702220 230 #1 1/0 42.41 02500230 02702230 240 1/0 2/0 53.49 02500240 02702240 250 2/0 3/0 67.43 02500250 02702250 260 3/0 4/0 85.01 02500260 02702260 270 4/0 250 26.67 02500270 02702270 Notes: Copper compression lug suitable for all copper conductor sonly. * Bi-metal compression lug with universal aluminum barrel suitable for copper or aluminum conductors. 8155 T&B Boulevard, Memphis, TN 38125 OMas Ma etts www.tnb.com 901-252-5000, FAX 901-252-1331 A Member of The AB8 Group File: roo-IJr%ljIVV1A 15kV Power Cable Joints 15PCJlWlX Features: • Molded conductive shield provides a virtually indestructible ground shield for true deadfront construction • Fully shielded, fully submersible molded rubber housing • Molded conductive insert precludes subjecting entrapped air to electrical stress • Grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing the molded shield at ground potential • Cable entrance engages the insulation shielding of the cable eliminating the need for taping 15PCJ1 Power Cable Joints Applications: Elastimold@ 15PCJ1 Power Cable Joints provide a permanent, fully shielded, fully submersible, straight splice. Typically, the 15PCJ1 can be used on new installations to join cable runs or for repairs to broken cables on existing installations. The 15PCJ1 is for 15kV use rated per IEEE Standard 404. Installed either directly buried or in a vault, the pin and socket interlock of the 15PCJ1 power cable joint will withstand pulls of up to 500 lbs. The 15PCJ1 is designed to accept cable insulation diameters of .640" to 2.120". The cable entrance of the housing provides electrical and water seal integrity. While designed for use on UD cable having concentric neutral and extruded insulation shielding, the 15PCJ1 will operating equally well on fabric tape shielded or lead -jacketed cables when used with the proper Elastimold@ cable shield adapter or grounding device. Ratings: Meets IEEE Standard 404, Latest Revision For 15kV Voltage Class: 110kV BIL — Impulse Withstand (1.2 x 50 microsecond wave) 35kV AC — Withstand 70kV DC —Withstand during Manufacture Test 56kV DC — During installation 13kV AC — Corona Extinction @ 3pC sensitivity Continuous current rating equal to that of cable rating. Short -time current rating equal to that of cable rating up to 35kA. Shield design meets IEEE Standard 592, Latest Revision Cyclic Aging: 30 days at 26.1 kV AC continuous, load current for 8 hours per day, providing 130°F conductor temperature. Connectors meet ANSI C119.4 Class A and Class 3 ratings. 8155 T&B Boulevard, Memphis, TNI 38125 www.tnb.com 901-252-5000, FAX 901-252-1331 Thomas o efts Dimensional Data Style 1 Part Number A B inches inches 15PCJIFX 101/4" 13/4" 15PCJIGX 101/4" 13/4" 15PCIIHX 14 3/8" 2 7/16" 15PCIIJX 14 3/8" 2 7/16" 15PCIIKX 14 3/8" 2 7/16" 15PCIILX 14 3/8"' 2 25/32"' 15PCIILMX 14 3/8" 2 25/32" 15PCI1MX 14 3/8" 2 25/32" 15PCIINX 15 3/4" 3 3/16" 15PCJlPX 15 3/4" 3 3/16" 15PCJlQX 15 3/4" 3 3/16" fJL__ I B Ll 1 CATALOG NUMBER SELECTION Step 1 (W) Determine the insulation diameter of the cable. Select the insulation letter code that best straddles the insulatic diameter from W table below. Insert code into catalog number. Step 2 Insert conductor material code. Step 3 (X) Material Code Choose the proper compression lug code according to the 1 conductor size from table 2. Insert code into catalog number. Alum. CU 2 W Code 1-1 15PCJ1 Cable Insulation Diameter in inches Symbol for W MIN. MAX. 0.760 0.950 G 0.850 1.050 H 0.980 1.180 J 1.090 1.310 K 1.180 1.465 L 1.280 1.430 LM 1.370 1.630 M 1.515 1.780 N 1.725 1.935 P 1.900 2.120 Q Each kit contains the following: 1 Power Cable Joint Housing 15PCJ1-W 1 Connector 02500XXX 1 Tube, lubricant 82-08 1 Installation instruction IS-0332 XXX Code 1: C U x x Conductor Size AWG or kcmil Strand./ Compr. Solid/ Comp. 180 #6 #5 190 #5 #4 200 #4 #3 210 #3 #2 220 #2 #1 230 #1 1/0 240 1/0 2/0 250 2/0 3/0 260 3/0 4/0 270 4/0 250 280 250 300 290 300 350 300 350 400 310 400 450/500 320 450 550 330 500 600 340 550 650 350 600 700 360 650 750 380 700/750 800/900 390 800 - 400 900 1000 410 1000 - 420 - 1250 440 1250 - Example: The ordering number for a power cable joint of style 1 with an insulation diameter of .995" to 1.090" with a #4 stranded aluminum conductor would be 15PCJ1J1200. To include sealing and grounding kit add 200ECS for neutral wire or 200ECS-G3 for copper line shield to the existing product number. Two kits are required for splice. 8155 T&B Boulevard, Memphis, TN 38125 901-252-5000, FAX 901-252-1331 www.tnb.com Thomas o etts A 1.W.Z& M fho ARR Geo-n Permit Type Electrical BUILDING PERMIT Permit Number: Property Address BELC2019-0014 79999 AVENUE 52 SILVERROCK / 12.5kV ELECTRICAL SERVICE RELOCATION *** 12.5kV ELECTRICAL FEEDER RELOCATION FOR GOLF COURSE PUMP HOUSE AND INSTALLATION OF 208Y/120V 100A FEEDER TO LAKE AT CURRENT 7/8 HOLES. 2016 CALIFORNIA BUILDING CODES. New Electrical Square 0 Electrical Service? Yes Footage Type Group Sq Ft Value Invoice No. Fee PERM IT-BELC2019-001 SERVICES PC SERVICES RECORDS MANAGEMENT FEE BSAS SB1473 FEE TECHNOLOGY ENHANCEMENT FEE Credit Card Fee PERMIT ISSUANCE RECORDS MANAGEMENT FEE Total for Invoice PERM IT-BELC2019-0014 Fee Amount Amount Paid $26.68 $26.68 $53.36 $53.36 $9.00 $9.00 $14.00 $14.00 $5.00 $5.00 $0.16 $0.16 $101.40 $101.40 $1.00 $1.00 $210.60 $210.60 Grand Total for Permit $210.60 $210.60 Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 01/29/2019 0:00 -------------------------------------------------- ELECTRICAL FINAL** v.1 -------- Inspection -------------------------------------------------- UNDERGROUND ELEC v.13 -------------------------------------------------------------------------------------- Inspection -------------------------------------------------- CODE DIVISION v.1 -------------------------------------------------------------------------------------- Inspection -------------------------------------------------- UNDERGROUND ELEC v.12 -------------------------------------------------------------------------------------- Inspection -------------------------------------------------- UNDERGROUND ELEC v.11 -------------------------------------------------------------------------------------- Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.10 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.9 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.8 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.7 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.6 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.5 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.4 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.3 Inspection UNDERGROUND ELEC v.2 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- UNDERGROUND ELEC v.1 Inspection Printed: 6/5/25 9:36 am Page 3 of 4 1091 Consulting Engineers, Inc. PROJECT: Silver Rock High Voltage Re -Route SUBMITTAL: Submittal 6 - 4 Way Terminators Reviewed F Furnish as Corrected F Rejected F Submit Specific Item F Revised & Resubmit F Exceptions Noted Corrects or comments made on the shop drawings during this review do not relieve contractor from compliance with the requirements of the construction documents. This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Submitting contractor is responsible for: correlating and confirming dimensions at the job site; choice of fabrication processes and techniques for construction: coordination of his work with that of other trades; and performing the work in a safe and satisfactory manner. RB Consulting Engineers, Inc. Date: 4/9/19 By: Ken Bertalan Comments: Approved 1044 Pioneer Way, Suite E, El Cajon, CA 92020 Telephone: 619.599.6973 Email: kbertalan@rbcengineers.com GRAIIITE' To: John Gamlin WE ARE SENDING YOU ❑ Shop Drawings ❑ Copy of Letter [21 Submittals ❑ Change Order Number Southern California Region Indio Area Office 38000 Monroe St. Indio, CA 92203 Phone (760) 775-7500 Fax (760) 775-8229 Cuhmittal #i 6 Date: January 24, 2019 Granite lob # SilverRock 12kv high voltage relocate City Project # Attn: Re: Submittal 06- 200A Loadbreak 4-way Junction p Attached ❑ Under Separate Cover via the following items: ❑ Prints ❑ Plans ❑ Samples ❑ Contract ❑ Subcontracts ❑ Invoices(s) ❑ Payroll Docs ❑ Certificate(s) of Insurance Copies Section -Page Description 1 Sheet E7.02 200Amp Loadbreak 4-way Junction ❑ Specifications THESE ARE TRANSMITTED AS CHECKED BELOW: [21 For Approval ❑ Approved as Submitted ❑ Resubmit _ Copies for Approval ❑ For Your Use ❑ Approved as Noted ❑ Submit _ Copies For Distribution ❑ As Requested ❑ Returned for Corrections ❑ Return _ Corrected Prints ❑ For Review and Comment ❑ ❑ For Bid Due By The ❑ Prints Returned After Loan To Us REMARKS: Attached please find product data for the 200A 4 way loadbreak for the above refrenced project Copy To: Job File Signed: Michael Taber IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE. Issue Date: Page: File: 10/11 /2012 1 of 2 PSS-164J4 15kV 200A Loadbreak 4-Way Junction w/ s.s. Bracket 1164.114 ,m :A Z _--J so Note: Red PBT Interface Shield available soon Features: • 15kV, 200 Amp Loadbreak 4-Way Junction • Fully shielded, fully submersible molded rubber housing • 100% peroxide -cured construction includes insulation and conductive EPDM materials • Provides mating for Elastimold0 Elbow connectors • Mounting hardware for flat or curved mounting positions • Stainless Steel Mounting brackets and hardware 164,14 Loadbreak 4-Way Junction Applications: ELASTIMOLDOjunctions are designed for subsurface, vault or padmount applications and can be used for sectionalizing, looping, tapping, and equipment bypass. Junctions are designed to mate with other ELASTIMOLDO products including: • 15kV Family of Elbow Connectors • 160GLR Grounding Elbow • 370TR Test Rod • 160DR/DRG Insulated Cap • 167/168DRG Insulated Cap ELASTIMOLDO loadbreak junctions, provide a fully shielded, fully submersible, separable, insulated assembly designed for energized operation. They are suitable for use on 15-kV class distribution systems, and rated for 200-ampere Ioadmake/load break operation. Junctions are equipped with universal brackets that accommodate curved or flat surfaces and provide tilt mounting angles from 0° to 90° in 15° increments. Ratings: Meets ANSI/IEEE Standard 386, Latest Revision For 15kV Voltage Class: 8.3kV Phase -to -Ground —Operating Voltage 14.4kV Max Phase -to -Phase 95kV BIL — Impulse Withstand (1.2 x 50 microsecond wave) 34kV AC — One minute withstand 53kV DC — 15 minutes withstand 11 kV AC — Corona Extinction @ 3pC sensitivity 200 Amp — Continuous and Loadbreak 10kA Sym — 10 Cycles Momentary & Fault Close 8155 T&B Boulevard, Memphis, TN 38125 www.tnb.com 901-252-5000,FAX 901-252-1331 Thomas efts A IuOFMbEm of the ARR Issue Date: 10/11/2012 Page: 2 of 2 File: PSS-164J4 15kV 200A Loadbreak 4-Way Junction w/s.s. Bracket 164.14 3.60" 91,4mm 1,80" 45,6mm Each kit contains the following: 1 Basic molded junction 164.14 4 Protective shipping cap 1601-APC-1 2 Tube, lubricant 82-08 1 Installation instruction IS-0415 9.41` 239,Omm 7,06' 179,3nm 18.11" TO 21.88' 435,0 TO 555,8mm MOUNTING DOLTS 4.26" 108,2r)rn 3,25` <TYP> 82,5mm CWFORMS TO ANSI .74" Ste[ 386, Flg 5 18,7mm Ordering Instructions: Specify 164J4 for 15kV, 200 Amp 4-way Loadbreak Junction. 8155 T&B Boulevard, Memphis, TN 38125 901-252-5000, FAX 901-252-1331 www.tnb.com Thomas MOM A AAFmbar of the ARM Grc..:, DESERT REDI-MIX WEIGHED AT: COMMENTS: ALL RETURNED CHECKS WILL BE CHARGED AT $35 00 SERVICE CHARGE CONTROL # ❑ 50-305 Highway 111 Fargo Canyon Quarry ❑ �Lqq Coachella, CA 92236 86-600 Fargo Canyon Rd OTHER: SPECIFY CHECK# (760) 398-7717 Indio, CA 92201 Concrete is a perishable commodity and becomes the property of the purchaser upon batching at the plant DRIVERS LIC. TO JOB ;L� Job -site Cylinder Test: El No TIME ON JOB MIN. REASON FOR DELAY TIME: ONJb6 Water added on job at OVERTIME 0 JOB NOT READY MIN. 0 TRUC13 JOB KBROKEEDKE OWN STARTPOUR FINISH POUR r Customer's request: gals to full Ld. gals to 2/3 Ld. ❑ Yes ❑ Yes RATE OF X $ $ PER MIN. 0 ADDING ARRIVEDJOB EARLY t] SLOW PLACING METHOD p 4 MIN. PER YD. FREE UNLOADING TIME ALLOWED. LEAVE JOB gals to 1/3 Ld. ❑ Yes ADDITIONAL UNLOADING TIME CHARGED AT CURRENT HOURLY TRUCK RATE. CREDIT CARD PAYMENTS WILL BE CHARGED 2.5% PROCESSING FEE ARRIVE PLANT I All disputes are submitted to binding arbitration with AAA except small claims. All venues in Indio, CORONET CONCRETE PRODUCTS INC, DBA DESERT REDI-MIX is released from any responsibility CA In event of default in payment of this invoice and it is necessary for seller to retain services of an for damages which may be incurred from delivering materials across the curb or property line. Additional attorney by reason thereof the buyer agrees to pay seller all costs and expenses incurred by person water added to concrete will reduce its strength and any water added to colored concrete will change its thereof including a reasonable attorney's fee plus 1.5% interest per month. color and reduce its strength, therefore any water added on site is at customers own risk. Not responsible CAUTION: Freshly mixed concrete may cause skin irritation on prolonged exposure. Avoid direct for ANY variations of color if projecUs not a continuous pour. contact where possible and wash exposed skin areas promptly with water. If any cementitious l materials get into the eye, rinse immediately and repeatedly with water and get prompt medical attention. Keep out of reach of children Received by PLANT DATE, CUSTOMER NO. SOLP TO CUSTOMER P.0/ JOB OR LOT NO :. f,l h TX CD DELI VERY ADDRESS & INSTRUCTIONS ORD NO. TICKET NOr TIMu TYPED ZONE NO, PROJECT PHONE NO. MAP PAGE LOAD NO SLUMP USE TRUCK NO. DRIVER ... DRIVER NO. LOAD CUMULATIVE ORDERED PRODUCT MIX AND PRODUCT UNIT OF UNIT QUANTITY QUANTITY QUANTITY CODE DESCRIPTION MEASURE PRICE AMOUNT LOAD WEIGHTSSD: The prices of taxable items include sales tax Reimbursement computed to the nearest mill TAX WEIGHMASTER CERTIFICATE PREVIOUS THIS IS TO CERTIFY that the following described commodity was weighed, measured or counted by a weighmaster whose signature is on this certificate, who is recognized authority of accuracy, BALANCE as prescribed by Chapter 7 (commencing with Section 12700) of Division 5 of the California SUBTOTAL Business and Professions Code. Administered by the Division of Measurement Standards of the California Department of Food and Agriculture. DESERT REDI-MIX OVERTIME CHARGE By ��` TOTAL INSPECTOR Deputy SIGNAL LEGEND FLUSH MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TO a BOTTOM OF BOX U.O.N. PROVIDE VC. TO ACCESSIBLE CEILING SPACE WITH PULL STRING, U.O.N. SURFACE MOUNTED TELECOM OUTLET MOUNTED AT +15" AFF TO BOTTOM OF BOX U.ON. PROVIDE VC. TO ACCESSIBLE CEILING SPACE WITH PULL STRING, U.O.N. FLUSH MOUNTED WALL PHONE OUTLET MOUNTED AT +44" AFF TO TOP OF BOX U.O.N FLUSH MOUNTED TELEVISION OUTLET MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N FLUSH FLOOR BOX WITH TELECOM OUTLET OFIRE RATED POKE THRU WITH TELECOM OUTLET WAP WIRELESS ACCESS POINT a CEILING MOUNTED TELECOM OUTLET PUSH BUTTON �B BUZZER �B BELL WALL MOUNTED SPEAKER OS CEILING MOUNTED SPEAKER SECURITY LEGEND ❑A ALARM CONTACT CR CARD READER KP KEYPAD GB GLASS BREAK MS MOTION SENSOR ES ELECTRIC DOOR STRIKE DC DOOR CONTACT DR REMOTE DOOR RELEASE EL ELECTRONIC LOCK VD VIBRATION DETECTOR DA DOOR BREACH ALARM PB PANIC BUTTON / DURESS ALARM REX REQUEST TO EXIT EHO ELECTRONIC HOLD OPEN EPH ELECTRONIC PANIC HARDWARE EML ELECTRONIC MAGNETIC LOCK ❑= FIXED POSITION VIDEO CAMERA PTZ PAN, TILT, ZOOM VIDEO CAMERA PHOTOVOLTAIC LEGEND 0 DC TO AC STRING INVERTER PHOTOVOLTAIC MODULE PANEL (PV PANEL) PHOTOVOLTAIC ARRAY (PV ARRAY) S#.# INVERTER NUMBER DESIGNATION STRING NUMBER DESIGNATION 'PI D-] POTENTIAL INDUCED DEGRATION (PID) ENERGY BALANCER CABINET WIRING LEGEND BRANCH CIRCUIT RACEWAY TO BE DEMOLISH BRANCH CIRCUIT RACEWAY CONCEALED IN WALL OR CEILING BRANCH CIRCUIT RACEWAY CONCEALED IN FLOOR OR UNDERGROUND RACEWAY EXPOSED r` RACEWAY TURNED UP 0 RACEWAY TURNED DOWN RACEWAY CAPPED AND STUBBED.PROVIDE PERMANENT GROUND MARKER FOR UNDERGROUND INSTALLATIONS L1 1 BRANCH CIRCUIT RACEWAY HOME RUN BACK TO ELECTRICAL EQUIPMENT AS NOTED BRANCH CIRCUIT RACEWAY WITH 3#12, 1#12N, 1#12GND, 3/4"C. MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N. #10 BRANCH CIRCUIT RACEWAY WITH 3#10, 1#10N, 1#10GND, 3/4"C. MAXIMUM THREE BRANCH CIRCUITS PER HOME RUN, U.O.N. • POINT OF CONNECTION TO EQUIPMENT CABLE TRAY WMX - SURFACE MOUNTED WIRE MOLD RACEWAY SYSTEM. X = 1, 2 OR 3 CHANNEL RACEWAY EQUIPMENT LEGEND F1 LIGHT FIXTURE DESIGNATION �HL1-13 LIGHTING BRANCH CIRCUIT (R1) RELAY DESIGNATION IN LIGHTING CONTROLPANEL AHU 1 MECHANICAL EQUIPMENT TAG M MOTOR RATED SWITCH SFD SMOKE FIRE DAMPER MOTOR Eli HEAVY DUTY NON -FUSED DISCONNECT HEAVY DUTY FUSED DISCONNECT MOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOT LIGHTS COMBINATION MOTOR STARTER, HOA, AUX CONTACTS, CPT, PILOT LIGHTS, WITH FUSED DISCONNECT SWITCH VFD VARIABLE FREQUENCY DRIVE. CONFIRM INTEGRAL DISCONNECTING MEANS WITH MECHANICAL FLUSH MOUNTED PANEL BOARD OR ELECTRICAL CABINET SURFACE MOUNTED PANEL BOARD OR ELECTRICAL CABINET DISTRIBUTION SWITCHBOARD OR PANEL BOARD ❑T TRANSFORMER EPO EMERGENCY POWER OFF BUTTON POWER LEGEND GFCI = GROUND FAULT CIRCUIT INTERRUPTER IG = ISOLATED GROUND S = SURGE SUPPRESSOR H = HORIZONTAL MOUNTED AC = MOUNT ABOVE COUNTER PER ARCHITECT ELEVATION XX USB = PROVIDED WITH INTREGRAL USB PORTS XX RC = RECEPTACLE CONTROLLED PER TITLE 24 2013 SECTION 130.5(d) C = CLOCK TYPE HALF SHADED WIRING INDICATES CONTROLLED RECEPTACLE PER TITLE 24 SECTION 130.5(d) o-� FLUSH MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N SURFACE MOUNTED SINGLE RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N c FLUSH MOUNTED HALF HOT DUPLEX RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N FLUSH MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFF TO c BOTTOM OF BOX U.O.N FLUSH MOUNTED DUPLEX RECEPTACLE MOUNTING HEIGHT TO BOTTOM OF BOX PER ARCHITECT ELEVATION FLUSH MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N FLUSH MOUNTED QUAD RECEPTACLE MOUNTING HEIGHT TO BOTTOM OF BOX PER ARCHITECT ELEVATION SURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N �❑ SURFACED MOUNTED DUPLEX RECEPTACLE MOUNTED AT COUNTER LEVEL PER ARCHITECT ELEVATION SURFACE MOUNTED QUAD RECEPTACLE MOUNTED AT +15" AFF TO Fv BOTTOM OF BOX U.O.N SURFACE MOUNTED QUAD RECEPTACLE MOUNTING TO BOTTOM OF BOX PER ARCHITECT ELEVATION XX-XXX SURFACE MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N XX-XXX FLUSH MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLE MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N XX-XXX CEILING MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLE XX-XXX FLOOR MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLE CEILING MOUNTED DUPLEX RECEPTACLE CEILING MOUNTED QUAD RECEPTACLE ® ❑ FLUSH FLOOR BOX WITH DUPLEX RECEPTACLE ® FLUSH FLOOR BOX WITH QUAD RECEPTACLE ® FLUSH FLOOR BOX WITH COMBINATION DUPLEX RECEPTACLE AND 2� ® �F DATA OUTLET ® FLUSH FLOOR BOX WITH COMBINATION QUAD RECEPTACLE AND ® DATA OUTLET ® FIRE RATED POKE THRU WITH DUPLEX RECEPTACLE ® FIRE RATED POKE THRU WITH QUAD RECEPTACLE FIRE RATED POKE THRU WITH DUPLEX RECEPTACLE AND DATA OUTLET FIRE RATED POKE THRU WITH QUAD RECEPTACLE AND DATA OUTLET RC RECEPTACLE POWER PACK MOUNTED IN ACCESSIBLE CEILING SPACE FOR AUTOMATIC CONTROL OF RECEPTACLE DEVICE FLUSH MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N SURFACE MOUNTED JUNCTION BOX MOUNTED AT +15" AFF TO BOTTOM OF BOX U.O.N FLUSH FLOOR MOUNTED JUNCTION BOX J❑ CEILING MOUNTED JUNCTION BOX CONTROL LEGEND D = DIMMING SWITCH XX K = KEYED SWITCH o} P = PILOT LIGHT SWITCH R = MOMENTARY CONTACT SWITCH T = TIMER SWITCH 3 = THREE WAY SWITCH FLUSH MOUNTED SINGLE POLE STANDARD TOGGLE SWITCH MOUNTED AT +48" AFF TO TOP OF BOX U.O.N. LETTERING INDICATES QUANTITY OF SWITCHES AND DEVICES TO BE CONTROLLED. } SURFACE MOUNTED SPST SWITCH MOUNTED AT +48" AFF TO TOP OF BOX U.O.N U = ULTRA SONIC OCCUPANCY SENSOR OC XX DT = DUAL TECHNOLOGY OCCUPANCY SENSOR OC FLUSH INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTON MOUNTED AT +48" AFF TO TOP OF BOX U.O.N OC ab FLUSH INFRARED WALL OCCUPANCY SENSOR DUAL BUTTON MOUNTED AT +48" AFF TO TOP OF BOX U.O.N OC SURFACE INFRARED WALL OCCUPANCY SENSOR SINGLE BUTTON MOUNTED AT +48" AFF TO TOP OF BOX U.O.N ab OC SURFACE INFRARED WALL OCCUPANCY SENSOR DUAL BUTTON MOUNTED AT +48" AFF TO TOP OF BOX U.O.N OC CEILING MOUNTED INFRARED OCCUPANCY SENSOR DL CEILING MOUNTED DAY LIGHT SENSOR FLUSH MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48" AFF TO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PER FLOOR PLAN O SURFACE MOUNTED OVERRIDE SWITCH STATION MOUNTED AT +48" AFF TO TOP OF BOX U.O.N. BUTTON CONFIGURATION AS NOTED PER FLOOR PLAN PC PHOTOCELL MOUNTED AND ORIENTATED AS NOTED ON FLOOR PLAN SINGLE LINE LEGEND DRAWOUT CIRCUIT BREAKER 100AF AMP FRAME 100AT AMP TRIP 3 POLE CONFIGURATION LSIG ELECTRONIC TRIP FUNCTIONS CIRCUIT BREAKER 100AF AMP FRAME 100AT AMP TRIP 3 POLE CONFIGURATION LSIG ELECTRONIC TRIP FUNCTIONS b FUSED SWITCH 100AS AMP SWITCH 100AF AMP FUSE 3 POLE CONFIGURATION ENCLOSED CIRCUIT BREAKER 100AF AMP FRAME 100AT AMP TRIP 3 POLE CONFIGURATION LSIG ELECTRONIC TRIP FUNCTIONS AV TRANSFORMER FUSE 1 GROUNDING ELECTRODE �O ELECTRONIC METERING UNIT CURRENT TRANSFORMER POTENTIAL TRANSFORMER NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT OCOIL ST SHUNT TRIP SS SOLID STATE TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION XXXX FEEDER TAG AUTOMATIC TRANSFER SWITCH PACKAGE ENGINE GENERATOR PANEL HL1 PANEL BOARD STRINGER INVERTER AkE + PHOTOVOLTAIC PANEL (PV PANEL) ABBREVIATIONS AND DESCRIPTIONS A / AMP AMPERE KW KILOWATT AC ALTERNATING CURRENT KWH KILOWATT HOUR A/C AIR CONDITIONING LBS POUNDS ABV ABOVE LF LINEAR FEET ADA AMERICAN WITH DISABILITIES ACT LTG / LTS LIGHTING AF AMPERE FRAME, AMPERE FUSE LV LOW VOLTAGE AFF / A.F.F. ABOVE FINISH FLOOR M METER AFG, A.F.G. ABOVE FINISH GRADE MAX MAXIMUM AIC / A.I.C. AMPERE INTERRUPTING CAPACITY MCA MINIMUM CIRCUIT AMPERES AL ALUMINUM MCB MAIN CIRCUIT BREAKER AS AMPERE SWITCH MCC MOTOR CONTROL CENTER AT AMPERE TRIP MDF MAIN DISTRIBUTION FRAME ATS AUTOMATIC TRANSFER SWITCH MECH MECHANICAL AVG AVERAGE MFR MANUFACTURER AWG AMERICAN WIRE GAUGE MH MANHOLE BKR BREAKER M.H. METAL HALIDE BLDG BUILDING MIN MINIMUM BR BRANCH MLO MAIN LUGS ONLY C CONDUIT MOCP MAXIMUM OVERCURRENT CIRCUIT PROTECTION CATV CABLE TELEVISION MTD MOUNTED CCTV CLOSED CIRCUIT TELEVISION MTG MOUNTING CB CIRCUIT BREAKER MV MERCURY VAPOR CBC CALIFORNIA BUILDING CODE N / NEUT NEUTRAL CEC CALIFORNIA ELECTRIC CODE NC NORMALLY CLOSED CFC CALIFORNIA FIRE CODE NEC NATIONAL ELECTRICAL CODE CIRC / CKT CIRCUIT NEMA NATIONAL ELECTRICAL MFR ASSOCIATION CL CENTER LINE NF NON -FUSED CLG CEILING NFPA NATIONAL FIRE PROTECTION ASSOCIATION CO / C.O. CONDUIT ONLY NIC NOT IN CONTRACT CONN CONNECTED NIL NIGHT LIGHT COMM COMMUNICATIONS NO NORMALLY OPEN CPT CONTROL POWER TRANSFORMER NO. / # NUMBER CSFM CALIFORNIA STATE FIRE MARSHALL NTS NOT TO SCALE CT CONTROLTRANSFORMER OC ON CENTER CTR CENTER OFCI OWNER FURNISH, CONTRACTOR INSTALLED CU COPPER P POLE (D) DEMOLISH PA PUBLIC ADDRESS DC DIRECT CURRENT PB PULL BOX DIET DETAIL PC PHOTOCELL DIA DIAMETER PDU POWER DISTRIBUTION UNIT DIM DIMENSION PF POWER FACTOR DISC DISCONNECT PH / o PHASE DIST DISTRIBUTION PNL PANEL DP DISTRIBUTION PANEL PRIMARY OVER 600 VOLTS DWG DRAWING PROVIDE FURNISH, INSTALL AND/OR CONNECT (E) EXISTING PT POTENTIAL TRANSFORMER EA EACH PVC POLYVINYL CHLORIDE EC ELECTRICAL CONTRACTOR PWR POWER EF EXHAUST FAN QTY QUANTITY EG EQUIPMENT GROUND REC RECESSED ELEC ELECTRICAL RECEIPT RECEPTACLE EM EMERGENCY REQD REQUIRED EMS EMERGENCY MANAGEMENT CONTROL SYSTEM REQT(S) REQUIREMENT(S) EMT ELECTRICAL METALLIC TUBING REFRIG REFRIGERATOR ENT ELECTRICAL NON-METALLIC TUBING RGS RIGID GALVANIZED STEEL CONDUIT EOL END OF LINE RESISTOR RM ROOM EP EXPLOSION PROOF RIMS ROOT MEAN SQUARE EPO / E.P.O EMERGENCY POWER OFF SCC SHORT CIRCUIT CURRENT EQP EQUIPMENT SECONDARY 600 VOLTS AND LESS EXO DISCONNECT SWITCH SFD SMOKE FIRE DAMPER FA FIRE ALARM SHT SHEET FACP FIRE ALARM CONTROL PANEL SPEC SPECIFICATIONS FATC FIRE ALARM TERMINAL CABINET SO SQUARE FIN FINISH STC SIGNAL TERMINAL CABINET FL FLOOR SW SWITCH FLA FULL LOAD AMPS SWBD SWITCHBOARD FT /' FEET SWGR METAL CLAD SWITCHGEAR G/GND GROUND TC TIMECLOCK GALV GALVANIZED TEL TELEPHONE GC GENERAL CONTRACTOR TEL/DAT TELEPHONE AND DATA GFCI GROUND FAULT CIRCUIT INTERRUPTER TEMP TEMPERATURE OR TEMPORARY GFP GROUND FAULT PROTECTION TV TELEVISION GEC GROUNDING ELECTRODE CONDUCTOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION H / HGT HEIGHT TYP TYPICAL HACR HEATING AIR CONDITIONING REFRIGERATION UGPS UNDERGROUND PULL SECTION HID HIGH INTENSITY DISCHARGE UL UNDERWRITERS LABORATORIES HOA HAND OFF AUTO LON / U.O.N. UNLESS OTHERWISE NOTED HP HORSEPOWER UPS UNINTERRUPTIBLE POWER SUPPLY HIPS HIGH PRESSURE SODIUM V VOLTAGE HR HOUR OR HOME RUN VA VOLT AMPERES HVAC HEATING, VENTILATING AND AIR CONDITIONING VAV VARIABLE AIR VOLUME HZ HERTZ VD VOLTAGE DROP IC INTERCOM VFD VARIABLE FREQUENCY DRIVE OF INTERMEDIATE DISTRIBUTION FRAME W WATTAGE OR WIRE IG ISOLATED GROUND WAP WIRELESS ACCESS POINT IMC INTERMEDIATE METAL CONDUIT WH WATER HEATER IN /" INCHES WP WEATHERPROOF IF INTERNET PROTOCOL WT WEIGHT JB / JBOX JUNCTION BOX X / (X) EXISTING KAIC KILOAMPERE INTERRUPTING CAPACITY XFMR TRANSFORMER KCMIL / MCM THOUSAND CIRCULAR MILS XL / (XL) EXISTING TO BE RELOCATED KS KNEE SPACE XN / (XN) EXISTING NEW LOCATION KV KILOVOLT XR / (XR) EXISTING TO BE REMOVED KVA KILOVOLT AMPERE %Z PERCENTAGE IMPEDANCE SHEET INDEX SHEET NUMBER SHEET TITLE E0.01 COVER SHEET E1.00 DEMOLITION PLAN E1.01 SITE PLAN E7.01 ELECTRICAL DETAILS E7.02 ELECTRICAL DETAILS E8.01 SINGLE LINE DIAGRAM GENERAL PROJECT NOTES 1. CONTRACTOR TO OBTAIN PERMISSION FOR ACCESS TO THE SITE FROM THE OWNER OR DESIGNATED OWNER REPRESENTATIVE TO VISIT THE SITE INCLUDING ALL AREAS OF WORK PRIOR TO BID. CONTRACTOR TO BE FAMILIARIZED WITH EXISTING CONDITIONS, VERIFY SAID CONDITIONS, DIMENSIONS, AND ROUTINGS PRIOR TO START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO OWNER / ARCHITECT / ENGINEER WITHIN 48 HOURS OF DISCREPANCIES FOUND. 2. CONTRACTOR SHALL CONFIRM ACCURACY OF PANEL BOARD INFORMATION PRIOR TO START OF WORK. REPORT ANY DISCREPANCIES TO OWNER / ARCHITECT / ENGINEER WITHIN 48 HOURS OF DISCREPANCIES FOUND. 3. ALL WORK SHOWN IS NEW UNLESS OTHERWISE NOTED. 4. ALL AREAS OUTSIDE THE SCOPE OF WORK SHALL BE PROTECTED IN PLACE AND REMAIN INTACT, U.O.N. 5. CONTRACTOR TO COORDINATE WITH OWNER ANY SHUTDOWN OF ELECTRICAL EQUIPMENT WITH 7 DAYS NOTIFICATION. CONTRACTOR TO INCLUDE OFF HOURS IN PRICING FOR THIS WORK. 6. ALL ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE NEW BEARING A UL LISTING OR ACCEPTABLE NRTL LISTING FROM THE LOCAL AREA JURISDICTION. 7. CONTRACTOR SHALL COMPLY WITH THE CURRENT VERSION OF THE CALIFORNIA ELECTRICAL CODE 2016, STATE, LOCAL CODES, ORDINANCES, AND REGULATIONS. 8. WORK SHALL BE PERFORMED IN A SAFE MANNER AND NOT DISTURB OR AFFECT EXISTING BUILDING UTILITIES, OCCUPANTS, OR FINISHES WITHOUT PRIOR NOTICE AND APPROVAL FROM OWNER. 9. ALL CONDUIT RUN SHALL BE FIELD COORDINATED, LOCATE CONDUITS CLEAR OF OTHER TRADES, DOOR ACCESS, OR OTHER OBSTRUCTIONS. COORDINATE CONDUIT RUNS WITH OTHER TRADES PRIOR TO COMMENCEMENT OF WORK. 10. RUN ALL CONDUITS CONCEALED IN CEILING SPACES, U.O.N. TO BE SURFACE MOUNTED. ALL CONDUIT PATHWAYS MUST MAINTAIN 6 INCHES CLEAR OF SOURCES OF HEAT, SUPPORT CONDUITS FROM STRUCTURE. 11. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE GREEN GROUND INSULATED CONDUCTOR. 12. ALL BRANCH CIRCUITS TO BE PROVIDED WITH SEPARATE WHITE NEUTRAL INSULATED CONDUCTOR. SHARED NEUTRAL IS ACCEPTABLE IF COMMON HANDLE TIE CIRCUIT BREAKER ARE UTILIZED TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS PER NEC 210.4(B). 13. PROVIDE IDENTIFICATION TAGS FOR ALL WIRING, INSTALL TAGS AT END OF RUNS, INTERMEDIATE PULL BOXES, JUNCTION BOXES, CABINETS, ETC. 14. BRANCH CIRCUIT VOLTAGE DROP NOT TO EXCEED 3% FROM PANEL BOARD SOURCE. 15. LABEL ALL CIRCUIT BREAKERS IN ALL ELECTRICAL DISTRIBUTION PANELS AND SWITCHBOARDS. PROVIDE TYPE WRITTEN CIRCUIT DIRECTORY CARDS FOR ANY PANEL BOARD HAVING CIRCUIT MODIFICATIONS. 16. PROVIDE P-TOUCH LABELS ON ALL NEW OUTLETS, RACKS, PLUG MOLD, AND SWITCHES. 17. ALL CONDUITS PENETRATING ELECTRICAL/MECHANICAL SPACES OF RATED WALLS SHALL BE SEALED AND FIRE STOPPED. 18. ALL ELECTRICAL PENETRATIONS INTO COOLER OR FREEZER UNITS SHALL BE SEALED PER SECTION 300-7 OF THE NEC. PROJECT SCOPE: FUTURE HOTEL DEVELOPMENT REQUIRES THAT THE EXISTING MEDIUM VOLTAGE SYSTEM POWERING THE GOLF COURSE PUMP HOUSE BE RELOCATED TO ALLOW FOR THE MASS EXCAVATION FOR THE HOTEL AND ASSOCIATED BUILDING. SHEET E1.00 INDICATES THE AREAS OF DEMOLITION AND SHEET E1.01 INDICATES THE NEW ROUTING. ADDED SCOPE OF WORK DESCRIPTION BELC2019-0014 a TY OF LA QU I NTA BUI LDI NG DI VI SI ON APPROVED FOR CONSTRUCTI ON BY: A. DATE: 03/20/2019 12.5kV ELECTRICAL FEEDER RELOCATION FOR GOLF COURSE PUMP HOUSE AND INSTALLATION OF 208Y/120V 100A FEEDER TO LAKE AT CURRENT 7/8 HOLES. 2016 CALIFORNIA BUILDING CODES. SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 Rowan Ele7 ctric 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS. ERRORS. OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 Q�OFESS/o -` - ` E19124' _' n * Exp.06/30/18 F lFCTR \FOF CA1-�F�� I.7 Yy mI•] %p�lIII E.31IIL' 1.3 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal / Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description COVER SHEET Scale As indicated E0n01 © 2015 Gensler FA � I � \ r 1 I 1 / GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY EXISTING HIGH VOLTAGE CONDUIT ROUTING PRIOR TO COMMENCEMENT OF WORK UTILIZING UNDERGROUND CABLE LOCATING SERVICES. 2. UNDERGROUND CONDUIT BURIAL DEPTH SEE SHEET E7.02. 3. SEE SHEET E1.01 FOR NEW HIGH VOLTAGE ROUTING KEYNOTES 10 EXISTING HIGH VOLTAGE FEEDER AND CONDUITS. FEEDERS TO BE REMOVE, CONDUITS TO BE ABANDONED IN PLACE. O2 EXISTING HIGH VOLTAGE HANDHOLE TO BE REMOVE. O3 EXISTING HANDHOLE TO REMAIN IN PLACE. NEW HIGH VOLTAGE TO INTERCEPT EXISTING MANHOLE. O4 EXISTING HIGH VOLTAGE LINES TO REMAIN. O EXISTING HANDHOLE TO REMAIN IN PLACE O6 CONTRACTOR TO SEE SHEET E1.01 FOR NEW HANHOLE LOCATION. O7 CONTRACTOR TO VERIFY EXISTING HIGH VOLTAGE LINE, PRIOR TO COMMENCEMENT OF WORK. SEE SHEET E1.01 FOR ADDITIONAL REQUIREMENTS. IF HIGH VOLTAGE LINE EXIST, CONDUIT AND CONDUCTORS TO BE REMOVE. O AREA OF SCOPE FROM NOTE 4. SINGLE LINE DIAGRAM SHEET E8.01 Q ADDED NOTE a TY OF LA QUI NTA I3tJ1 MI NG DI VI SI ON APPROVED FOR CONSTRUCTI ON BY: A. a h_ _ DATE: 03/20/2019 SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 Rowan Electric 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS, ERRORS, OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 RBCE JOB #2018- 0048 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal / Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description DEMOLITION PLAN Scale As indicated El n00 DEMOLITION PLAN SCALE: 1" = 70' NORTH © 2015 Gensler GENERAL NOTES CONTRACTOR TO FIELD VERIFY EXISTING HIGH VOLTAGE CONDUIT ROUTING PRIOR TO COMMENCEMENT OF WORK UTILIZING UNDERGROUND CABLE LOCATING SERVICES. UNDERGROUND CONDUIT BURIAL DEPTH SEE SHEET E7.02. CONTRACTOR UTILIZED HIGH VOLTAGE SPLICE -TERMINATION COMPONENTS AS MANUFACTURER BY RAYCHEM CORP OR EQUAL APPROVED. ALL UNDERGROUND CONDUITS TO BE SCH 40 AND CONCRETE ENCASED, WITH 250OPSI RED COLORED CONCRETE. KEYNOTES APPROXIMATE LOCATION OF NEW HIGH VOLTAGE FEEDER ROUTING. APPROXIMATE LOCATION OF NEW HIGH VOLTAGE FEEDER, FOR CONNECTION TO EXISTING PUMP HOUSE TRANSFORMER. CONTRACTOR TO PROVIDE ROUTING NOT EXCEEDING 500' BEFORE ADDING A HANDHOLE. PROVIDE NEW HANDHOLE FOR NEW HIGH VOLTAGE FEEDER ROUTING. EXISTING HANDHOLE TO REMAIN. HIGH VOLTAGE CONDUCTOR FROM THIS HANDHOLE BACK TO PUMP HOUSE SHALL BE REMOVED. EXISTING HANDHOLE TO REMAIN. HIGH VOLTAGE CONDUCTORS FROM THIS HANDHOLE BACK TO ELECTRICAL EQUIPMENT "DSBN4H" SHALL REMAIN IN PLACE. CONTRACTOR TO INTERCEPT EXISTING 12.5KV LINE AT THIS POINT. EXISTING CONDUIT AND FEEDERS TO REMAIN AT THIS LOCATION CONTRACTOR TO PROVIDE NEW HANHOLE 3315 FOR MEDIUM VOLTAGE CONNECTION. PROVIDE (1) CONNECTION FOR EXISTING PUMP HOUSE LOCATED ADJACENT TO THIS HANHOLE AND (1) CONNECTION FOR NEW ROUTE TO EXISTING NORTH PUMP HOUSE. PROVIDE ALL NECESSARY CONNECTIONS. AT THIS LOCATION CONTRACTOR TO REMOVED EXISTING HIGH VOLTAGE CABLE RUNNING TO PUMP HOUSE. CONDUIT RUNNING FROM THIS HANDHOLE TO EXISTING PUMP HOUSE WOULD BE REMOVED DURING PROJECT MASS EXCAVATION. CONTRACTOR TO PROVIDE 3#250 AL KCMIL, 1#1/0 AL GND, 3"C. SEE SINGLE LINE FOR ADDITIONAL INFORMATION. AVOID GOLF IRRIGATION MAINLINES IN THIS AREA. CVWD IRRIGATION LINE EASEMENT. SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 1-1*0- -No%) Rowan Electric 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS, ERRORS, OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 RBCE JOB #2018- 0048 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal / Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description SITE PLAN Scale As indicated V I I L I L/-I1 Y SCALE: ######## 4 NORTH El n0l © 2015 Gensler Recessed Lifting Har 5/16" Diamond Plate 2 Pc. Traffic Cover 3'-0" x 5'-0" 6" Top W/ 3'-0" x 5-0" Two Pc. RPM Cover 2 Ton Swiftlifts 2 Ea. Side Wall 4 Total 10" x 16" Knockout 2 Ea. Side Wall 4 Total 1"0 Ground Rod Knockout 2 Total Approximate Weights Base Slab — 2000 Lbs 39 Riser — 3500 Lbs 6" Riser — 470 Lbs 12" Riser — 940 Lbs Oldcast le Precast 11"UTILff VAULT u,,ision Southern California Fontana, San Diego, Santa Paula Phone: 800-626-3860 Fax: 909-428-3737 L I V11 JM/II Lill L5 Side Wall of OPTIONAL 12" Riser 6" Riser 3'-0" x 5'-0" Body 2 Ton Swiftlifts 2 Ea. Side Wall 4 Total 1 /2" 0 i-5000 Plastic Inserts For Cable Racks 4 Ea. Side Woll 8 Total \1— 2'-8" x 2'-8" x 1'-0" Deep Recess 8 2 Ton Swiftlifts 4 Total 6"0 Sump J 7/8"0 Pull Irons 2 Total SCALE:1/4" = 1'-0" EDISON 35481P FILE NAME: 070UEP35481PED.DWG ISSUE DATE: January 2005 www.oldcwtlepromt.com 3'-0" x 5'-0" Intercept Base Overall Outside Dimensions 3'-8"W x 7'-2"L x 57 1/2"H Overall Inside Dimensions 3'-0"W x 5'-0"L x 48"H 3'-0" x 5'-0" x 4'-0" Intercept Pullbox Edison UGS #225.1 Copyright ® 2008owaan: v�. ,: GROUND ROD AND BONDING REQUIREMENTS:�AADDED 1. INSTALL (S)10'X3/4" COPPER CLAD GROUND ROD AT EACH HANDHOLE. CADWELD (1) #2 COPPER BONDING CONDUCTOR TO GROUND ROD. CONNECT MEDIUM VOLTAGE CABLE SHIELDING TO #2 BONDING CONDUCTOR. CONNECT #6 COPPER BONDING CONDUCTOR TO ALL EXPOSED METAL COMPONENTS IN THE HANDHOLE, METAL COVER AND CONNECT THIS BONDING CONDUCTOR TO THE #2 BONDING CONDUCTOR. TYPICAL HIGH VOLTAGE HANDHOLE DETAIL NOT TO SCALE 48' Mik S S ACKFILL TO MATCH EXISTING GRADE ,T LANDSCAPED AREAS. EW ASPHALT OR CONCRETE PAVING 0 MATCH EXISTING AVING BASE NDISTURBED EARTH ELECTED BACKFILL FREE OF ARGE DEBRIS AND COMPACTED 0 90% RELATIVE DENSITY -4" PVC C.O. JTILITY PRIMARY) ONCRETE ENCASMENT COLOR RED I- PSI TRENCH DETAIL —1 CONDUIT (4') NOT TO SCALE 0 TY OF LA QU I NTA BUI LDI NG DIVISION APPROVED FOR CONSTRUCTI ON BY: A. DATE: 03/20/2019 DETAIL WAS MOVED FROM SHEET E7.02 SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 HOwan Ilectriclectf-C 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS, ERRORS, OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 RBCE JOB #2018- 0048 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal / Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description ELECTRICAL DETAILS Scale As indicated ELECTRICAL DETAILS SCALE: NONE E7n01 © 2015 Gensler 15kV Primary UD TRXLP 15kV Primary Cable UD Jacketed Aluminum or Copper Conductor. TRXLP Insulation. Bare Copper Concentric Neutrals. Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary underground distribution in conduit systems; suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15,000 volts or less and at conductor temperatures not to exceed 90'C for normal operation. SPECIFICATIONS Southwire 15kV HI-DRI Primary UD TRXLP Cable meets or exceeds the following ASTM specifications: • B3 Soft Annealed Copper Wire • B8 Concentric -Lay -Stranded Copper Conductors, Hard, Medium -Hard or Soft • B230 Aluminum, 1350-H19 Wire for Electrical Purposes • B231 Aluminum 1350 Conductors, Concentric -Lay -Stranded • B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes Southwire 15kV HI-DRI Primary UD TRXLP Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the order listed: • ANSI/ICEA S-94-649 • AEIC CS-8 • UL1072, When Specified • RUS U-1 CONSTRUCTION The cable is composed of a solid or moisture blocked reverse lay, compressed stranded soft drawn copper, or a solid or moisture blocked reverse lay or unilay compressed stranded 1350-H16/26 aluminum phase conductor, covered by a semi -conducting cross -linked polyethylene strand shield, a tree -retardant cross -linked polyethylene primary insulation, and a semi -conducting cross -linked polyethylene insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and a sunlight resistant, -40'C rated, insulating linear low density polyethylene jacket are applied over the insulation shield. The cable is identified by surface print on the jacket and with the lightning bolt symbol for supply cables indented in the jacket. Red extruded stripes available upon request. A semi -conducting polyethylene jacket is also available upon request. • Copyright 2013. Southmre Compiny 0 �Otit�1H71'(' MADE AP R.ghts Reserved USA MEDIUM VOLTAGE 15 KV CAPPER CABLE 15kV Primary UD TRXLP Phase Conductor Neutral Thickness Per Cond. (mils) Weight Allowable Diameter (mils) 1000 feet Ampacities+ Size Strand- No. of Size (AWG or kcmil) I ing Wires (AWG) Nominal Insul. Insul. Shield min. Point Approx. JkL Bare Phase mod. Over Over Insul. Insul. Shield Comp. Cable Comp. Direct In Cable Burial Ducts ALUMINUM CONDUCTOR - 0.220" INSULATION - 133% INSULATION LEVEL 2 2 Solid 10 14 220 30 30 50 258 745 825 1053 511 168' 11V 7 10 14 220 50 283 770 850 1078 530 168* 119* 1 Solid 13 14 220 220 30 30 50 289 778 858 1086 580 193* 137* 1 19 13 14 50 322 810 890 1118 602 193' 137* 110 Solid 16 14 220 30 50 325 813 893 1121 1 654 218* 155* 1/0 19 16 14 220 30 50 352 840 920 1148 673 218* 155* 2/0 19 20 14 220 30 50 395 883 963 1191 769 248' 177* 3/0 19 25 14 220 30 50 443 930 1010 1238 886 284* 201* 4/0 19 20 12 220 30 50 498 985 1065 1327 1067 324' 230* 250 350 37 16 10 37 18 14 220 220 40 40 50 50 558 661 1055 1155 1158 1258 1459 1486 1316 360* 1137 389*' 257* 319** 500 37 25 14 220 40 50 789 1285 1385 1613 1439 468'* 384" 750 61 24 12 220 40 80 968 1475 1575 1891 2053 569** 468'* 1000 61 20 10 220 55 80 1117 1623 1753 2110 2639 642" 542" 1250 91 25 10 220 55 80 1250 1765 1895 2253 1 3142 688** 604** 1500 1 91 30 10 220 55 80 1370 1 1885 2015 2373 1 3615 726" 1 637" COPPER CONDUCTOR - 0.2W INSULATION -133% INSULATION LEVEL 2 Solid 16 14 220 30 50 258 745 825 1053 723 210* 150* 2 I 7 16 14 1 Solid 20 14 220 220 30 30 50 50 283 289 770 850 778 858 1078 744 210* 1086 840 240* 150* 171' 1 19 20 14 220 30 50 322 810 890 1118 865 240* 171* 110 Solid 25 14 1/0 19 25 14 220 30 30 50 325 362 813 893 850 930 1121 984 273* 194* 194' 220 50 1158 1015 273' 2/0 19 20 12 220 30 50 405 893 973 1234 1230 313* 224' 3/0 19 25 12 220 30 50 456 943 1023 1284 1460 358* 255* 4/0 19 20 10 220 30 50 512 1000 1080 1384 1795 410* 293* 250 37 24 10 220 40 50 1558 1055 1155 1459 2095 446' 322* 350 37 18 12 220 40 50 661 1158 1258 1519 2048 489** 400** 500 37 26 12 220 40 50 789 1285 1385 1647 2744 577" 472*' 750 61 25 10 220 40 80 968 1475 1575 1 1933 4016 649" 532" 1000 61 26 9 220 55 80 1117 1623 1753 2135 5209 720** 630** 1250 91 26 8 220 W W 1250 1766 1895 2306 6400 760" 667" + Ampacities shown assume use of 100% load factor, 60 Hz current, 36' burial depth, 20*C ambient temperature, 90*C conductor temperature, earth RHO 90, insulation and shield RHO 400 Full neutral constriction (Ampacities assume - single phase circuit, one cable ** 113 neutral cable (Ampacities assume - three phase circuit, 3 cables tri lexed, multi -point grounding per ICEA methods a�-,��. One Southwire Drive souYiw� Carrollton. GA 30119 USA Southwire is a registered trademark of Southwirs Company 770/832-4242 www southwire.com 15kV Primary UD TRXLP Weight Allowable Phase Conductor Neutral Thickness Per Cond. (mils) Diameter(mils) 1000t'eet Ampacities+ Insul. Size Strand- No. pp of Size Nominal Shield Arox. Bare Over Owr Comp. Comp. Direct In (AWG or Phase Insul. kcmil) ing Wires {AWG} Insul. min. Jam• Cond. Insul. Shield Cable Cable Burial Ducts Point ALUMINUM CONDUCTOR 2 Solid 10 14 175 30 -100% INSULATION 1 258 LEVEL 6537 733 961 453 1 168' 119* 50 2 7 1 Solid 10 14 13 14 13 14 16 14 16 14 20 14 175 30 175 30 175 30 175 30 50 50 50 50 283 289 322 325 352 395 678 685 758 765 986 993 470 520 168* 193* 119* 137* 137* 155* 1 19 110 Solid 718 720 798 8W 1026 1028 539 591 193* 218* 1/0 19 210 19 175 175 30 30 50 50 748 790 828 870 1056 1098 609 703 218* 248' 155* 177' 310 19 25 14 20 12 175 30 30 50 443 838 893 918 1146 817 993 284* 201* 410 19 175 50 498 973 1234 324* 230' 250 37 16 10 176 30 50 558 963 1043 1346 1213 360* 257* 350 37 18 14 175 40 50 661 1068 1168 1396 1 1055 389-- 319— Soo 37 25 14 175 40 50 789 1193 1293 1521 1349 468** 384** 750 61 24 12 175 40 80 968 1383 1483 1798 1946 569" 468'* 1000 61 1250 91 20 10 25 10 175 40 80 1117 1530 1630 1988 2473 642** 542** 604** 220 55 80 1250 1765 1 180 2253 3142 688" 1500 91 30 10 1 220 55 80 1370 1885 1 2015 2373 3616 726" 1 637** COPPER CONDUCTOR -100% 2 Solid 16 14 175 30 50 INSULATION LEVEL 733 961 664 210* 1 150* 258 653 2 7 16 14 175 30 50 50 283 289 678 758 986 684 210* 150* 171* 1 Solid 20 14 175 30 685 765 993 780 240* 1 19 20 14 175 30 50 322 718 798 1026 803 240* 171* 1/0 Solid 25 14 175 30 50 325 720 800 1028 922 273* 194* 1/0 19 25 14 175 30 175 30 50 362 758 838 1066 951 273* 194' 2/0 19 20 12 50 405 800 880 1142 1161 313* 224* 3/0 19 4/0 19 25 12 20 10 24 10 18 12 26 12 25 10 26 9 26 8 175 30 30 50 50 456 512 853 908 933 1194 1390 358* 410* 255* 175 988 1291 1717 293* 250 37 350 37 175 175 30 40 40 40 40 55 50 50 558 661 963 1068 1043 1168 1346 1429 1992 1984 446* 489'* 322* 400" 500 37 750 61 175 175 50 80 789 968 1193 1383 1293 1483 1554 1840 2651 3906 577'* 849*' 472** 532*' 1000 61 1250 91 175 80 80 1 1117 1250 1 1001630 176511895 2013 1 2306 5041 6400 720" 760*' 630" 667** 175 + Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 200C ambient temperature, 90'C conductor temperature, earth RHO 90, insulation and shield RHO 400 ' Full neutral construction (Ampacities assume - single phase circuit, one cable) " 1/3 neutral cable (Ampacities assume - three phase circuit. 3 cables triplexed, multi -point grounding per ICEA methods) One Southwire Drive 0_%Uthwim Carrollton, GA 30119 USA 7701832-4242 'Southwire is a registered vadernark of Soudmire Company www southwtre.com 0 TY OF LA QU I NTA BUI LDI NG DIVISION APPROVED FOR CONSTRUCTI ON BY: A. DATE: 03/20/2019 L TO T E7.01 SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 Howan Electric 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS, ERRORS, OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 RBCE JOB #2018- 0048 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal 1 Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description ELECTRICAL DETAILS Scale As indicated ELECTRICAL DETAILS SCALE: NONE E7n02 © 2015 Gensler EXISTING 12.47V, 30, 3W, UNDERGROUND ELECTRICAL SERVICE. COORDINATE NEW TRENCH, CONDUITS, SWEEPS ETC. WITH ELECTRICAL UTILITY. EXISTING 400 A UNDERGROUND PULL SECTION EXISTING 400 A METER SECTION M 0 EXISTING DSBN NORTH 400 A 200 AF 150 AT 3P 1 G N EXISTING PANEL DSBN-1 H 400A, 480Y/277V, 30, 4W FU1H (3) 20E —(X)3#2 MV, 1#6 GND 3-1/2" C. EXISTING XFMR'TH1' 300KVA (X)1#3/0 GND 12.47-480/277V _ (X)2 (4#250 KCMIL, 1#3 GND, 4" C.) 400 AF 400 AT 3P (X)3#2 MV, 1#6 GND 3-1/2" C. 400 A (X)1#3/0 GND EXISTING PANEL DSBN-2L 800A, 208Y/120V, 30, 4W 0 FU1H (3) 20E —(X)3#2 MV, 1#6 GND 3-1/2" C. EXISTING XFMR'TH2' 300KVA 12.47-208/120V —(X)2(3#350, (LOCATED AT ENTRANCE TO 1#3 GND TEMP CLUBHOUSE) 3"C.) 800 AF 800 AT 3P FU1H (3) 50E (X)3#2 MV, 1#6 GND 3-1/2" C. EXISTING XFMR'TH3' 750KVA (X)1#3/0 GND4 12.47-480/277V (X)3(4#500, EXISTING PANEL DSBN-3H 1#2/0 GND 1000A, 480Y/277V, 30, 4W 4"C.) 1000AF 1000AT 800 A 3P (X)1 #3/0 GND (LOCATED AT NOTH IRRIGATION PUMP STATION) 1000 A 100 AF 200 AF 100 AF 100 AF 125 AF 200 AF 125 AF 100 AF 800 AF 200 AF 100 AF 60 AT 200 AT 100 AT 100 AT 125 AT 200 AT 125 AT 90 AT 800 AT 200 AT 50 AT 3P 3P 3P 3P 3P O 3P 3P 3P O 3P 3P 3P 1 1 1 G N G N GON SPARE SPARE (X) 4#3, (X) 3#350 KCMIL, 1#6 GND 1#3 GND, 1-1/4" C. 3" C. EXISTING EXISTING PANEL PANEL MPZ1H PSM CONTROL PANELPSM (X) (LOCATED 1#10 GND, PUMP 1" C. STATION MAIN ENTRY) EXISTING XFMR'TMPZ1' 25KVA 480 208Y/120V (X)1#6 GND (X)4#1/0, 1#8 GND, 1-1 /2"C. EXISTING PANEL MPZ1L MPZ #1 (LOCATED AT COMFORT STATIO NORTH) (X) 3#1/0, (X)1#3/0 CU 1#6 GND, TO COLD 1-1/2" C. WATER PIPE EXISTING (X)1#8 CU TO XFMR'T1L' GROUND ROD 75KVA (X)1#6 GND 480-208Y/120V (X)1#8 CU TO — GROUND RING (X) 4#4/0, 1#4 GND, 2-1 /2"C. EXISTING PANEL DSBN-1 L (LOCATED AT AT NORTH SERVICE) 4#3/0, 1#5 GND, 2"C. EXISTING PANEL GHN (LOCATED AT GATE HOUSE NORTH) (X) 2(4#350, 1#8 GND (X)1#3/0 CU 1#4 GND 1-1/2"C. TO LIFER 31-C.) -(X)1#3/0 CU TO EXISTING UJ EXISTING PUMP BUILDING STEEL EQUIPMENT PANEL LOCATED AT 1 TC GREEN (LOCATED AT TEMPORARY CLUBHOUSE) 3#250 AL KCMIL, 1#1/0 AL GND, (X)1#3/0 CU 3" C. TO COLD WATER PIPE (X)1#8 CU TO GROUND ROD (X)1#8 CU TO — GROUND RING lode gpa (X)1#3/0 CU (X) 2(3#400, (X) 3#2/0, TO LIFER 1#1/0 GND, 1#6 GND, 3"C.) 2"C. -(X)1#3/0 CU TO EXISTING EXISTING BUILDING STEEL PANEL PANEL IPCP NPZ4H IRRIGATION PUMP CONTROL PANEL. (X)1#3/0 CU TO COLD WATER PIPE (X)1#8 CU TO GROUND ROD (X)1#8 CU TO — GROUND RING (LOCATED (X) 3#6, INSIDE NORTH 1#10 GND, IRRIGATION 1" C. PUMP STATION) VOLTAGE DROP SCHEDULE DEVICE FEEDER BRANCH CIRCUIT TOTAL VOLTAGE DROP VOLTAGE DROP WIRE SIZE MAX VOLTAGE DROP WIRE SIZE DSBN-2L 0% (2)#600kcmil 4.05% (TAP 10) #250kcmil AL 4.05% AVENUE 52 NORTH SERVICE - A.C. SINGLE LINE DIAGRAM SCALE: NONE DSBN-2L ROOM EXTERIOR VOLTS 208Y/120V 3P 4W AIC 65,000 MOUNTING FLOOR BUS AMPS 800 MAIN BKR 800 FED FROM UTILITY NEUTRAL 100% LUGS STANDARD NOTE EXISTING CKT KVA LOAD BREAKER # CIRCUIT DESCRIPTION TRIP/POLES COND. FEEDER RACEWAY AND CONDUCTORS A B C 1 (X) LOAD 1 1 20/2 1/2"C,2#12,#12G 2 (X) LOAD 1 2011 1/2"C,1#12,#12N,#12G 3 (X) LOAD 1 1 20/2 1/2"C,2#12,#12G 4 (X) LOAD 1 2011 1/2"C,1#12,#12N,#12G 5 (X) LOAD 4.8 4.8 4.8 100/3 1-1/4"C,3#2,#8G 6 (X) LOAD 8.8 8.8 8.8 600/3 (2)3"C,3#350kcmil,#350kcmil N,#1G 7 SWITCHBOARD DB-1 38.3 44.3 40.3 600/3 (3)3"C,3#350kcmil AL,#350kcmil AL N,#3/0 AL G 8 (X) LOAD 4.8 4.8 4.8 100/3 1-1/4"C,3#2,#8G 9 (X) LOAD 15.1 15.1 15.1 800/3 (2)3-1/2"C,3#600kcmil,#600kcmil N,#1/0G 10 P-2 P-1 6.72 6.72 90/2 3"C,2#250kcmil AL,#250kcmil AL N,#1/0 AL G TOTAL CONNECTED KVA BY PHASE 82.5 86.5 73.8 CONN. KVA CALL. KVA CONN. KVA CALL. KVA LIGHTING 1.71 2.14 (125%) CONTINUOUS 83 104 (125%) LARGEST MOTOR 7.5 9.38 (125%) HEATING 0 0 (100%) OTHER MOTORS 28.4 28.4 (100%) NONCONTINUOUS 117 117 (100%) RECEPTACLES 5.18 5.18 (50%>10) KITCHEN EQUIP 0 0 (N/A) NONCOIN/DIVERSE 0 0 (N/A) TOTAL KVA 243 266 BALANCED THREE PHASE AMPS 738 EXSISTING XFMR'T3L' 30KVA 480-208Y/120V (X)1#6 GND (X) 4#2, 1#8 GND, 1-1 /2"C. EXISTING PANEL (LOCATED N1L INSIDE NORTH IRRIGATION PUMP STATION) (NORTH IRRIGATION BUILDING LIGHT AND POWER) LOAD SUMMARY EXISTING MV SERVICE EXISTING LOAD PER DISTRIBUTION BOARD "DSBN-2L" = 243.00 KVA EXISTING LOAD PER DISTRIBUTION BOARD "DSBN-3H" = 266.00 KVA X1.25% PER NEC 220.87 = 636.25 KVA TOTAL CONNECTED LOAD = 636.25 KVA AMP @ 12.47KV, 3 PHASE = 29.50 AMP (X)FEEDER FU1H DARKENED SINGLE LINE (3) 50E AREA OF CONDUIT ROUTING. —(X)3#2 MV, 1#6 GND 3-1/2" C. EXISTING XFMR'TH4' / 750KVA 12.47-480/277V —(X)3(4#500, 1#2/0 GND EXISTING PANEL DSBN-4H 4"C.) 1000A, 480Y/277V, 30, 4W 1000 AF 1000 AT 3P 1000AF "� 100 AF 1000AT o/) 100 AT 3P 3P (X)1#3/0 CU (X)3(4#500, (X)3#1, TO LIFER 1#2/0 GND 1#8 GND, 41-C.) 1-1/2"C. -(X)1#3/0 CU TO EXISTING BUILDING STEEL PANEL V1 CONTROL LU PANEL V1. (LOCATED EXISTING INSIDE PUMP PHASE II STATION CLUBHOUSE VILLAGE 1) 100 AF 60 AT 3P EXISTING 277/480V, 30, 4W, UNDERGROUND ELECTRICAL SERVICE. COORDINATE NEW TRENCH, CONDUITS, SWEEPS ETC. WITH ELECTRICAL UTILITY. EXISTING 1600 A UNDERGROUND PULL SECTION EXISTING 1600 A METER MAIN M 0 1600AF 1600AT 3P GFP EXISTING DSBN SOUTH 1600 A 200 AF 400 AF 100 AF 100 AF 100 AF 200 AT 400 AT 100 AT 100 AT 60 AT 3P 3P 3P 3P 3P 0 1 G N SPARE (X)3#350 KCMIL, (X)2 (4#250 KCMIL, (X)4#3/0, (X)4#4, (X)1#3/0 CU TO COLD (X)1#3/0 CU 1#3 GND, 1#3 GND, 1#8 GND 1#8 GND, TO LIFER 3" C. 4" C.) 2-1/2" C. 1-1/4" C. WATER PIPE EXISTING EXISTING EXISTING (X)1#8 CU TO (X)1#3/0 CU TO GROUND BUILDING STEEL PANEL PANEL PANEL ROD MPZ4H MPZ3H (X)1#8 CU TO GROUND RING CONTROL PANEL V3 (LOCATED LU EXISTING INSIDE PUMP PHASE II (X)3#4, (X)3#10, STATION MAINTENANCE 1#8 GND, 1#10 GND, VILLAGE 3) BLDG 1" C. 1/2" C. EXISTING EXISTING XFMR'TMPZ4' XFMR'TMPZ3' 45KVA 15KVA 480-208Y/120V 480-208Y/120V (X)1#6 GND (X)1#8 GND__f (X)4#1/0, (X)4#6, 1#6 GND, 1#10 GND, (LOCATED SOUTH OF PHASE II 1-1/2"C. 111C. CLUBHOUSE AREA) EXISTING EXISTING 1000A PANEL PANEL MPZ4L MPZ3L MPZ #4 MPZ #3 (LOCATED AT (LOCATED AT COMFORT CVWD TURNOUT STATIO SOUTH) SOUTH) 0 G N (X)4#4, (X)1#3/0 CU__ U (X)1#3/0 CU 1#8 GND, TO COLD TO LIFER 1-1/4" C. WATER PIPE EXISTING (X)1#8 CU TO (X)1#3/0 CU TO GROUND BUILDING STEEL PANEL ROD MPZ2H (X)1#8 CU TO GROUND RING (X)3#10, 1#10 GND, 1/2" C. EXISTING XFMR 'TMPZ2' 15KVA 480-208Y/120V (X)1#8 GND (X)4#6, 1#10 GND, 1"C. EXISTING PANEL MPZ2L MPZ #2 (LOCATED AT CVWD TURNOUT NORTH) a TY OF LA QU I NTA BUI I DI NG DI VI SI ON APPROVED FOR CONSTRUCTI ON BY: A.DATE: 03/20/2019 AVENUE 54 SOUTH SERVICE - A.C. SINGLE LINE DIAGRAM SCALE: NONE ADDED LOAD SUMMARY GENERAL NOTES- 1 . ALL ELECTRICAL DEVICE SHOWN ARE EXISTING TO REMAIN U.O.N. 2. ALL ELECTRICAL CONDUCTORS ARE EXISTING TO REMAIN, U.O.N. 3. ELECTRICAL PANELS ARE EXISTING TO REMAIN WITH MODIFIED LOADS. 4. NEW CONDUCTORS TO BE THWN-2/THHN-2 INSULATION, COPPER MATERIAL. 5. NEW CONDUIT RACEWAY TO BE EMT WITH SET SCREW FITTINGS. 6. E.C. IS TO PROVIDE IN HIS BID ALL COST FOR RUNNING UTILITIES SERVICE LATERAL, AND STRUCTURES, FROM ELECTRICAL UTILITY POINT OF CONNECTION TO MAIN SERVICE SWITCHGEAR. 7. E.C. IS TO TRANSITION FROM 90 DEGREE RATED CONDUCTORS TO 75 DEGREE RATED CONDUCTORS.WHEN TERMINATING INTO A THERMAL -MAGNETIC OVER CURRENT DEVICE RATED 75 DEGREE ILSCO TAP WITH CAP TO BE USED. 8. CONTRACTOR WILL PROVIDE LETTER TO ENGINEER CONFIRMING ALL EQUIPMENT AND TERMINATIONS ARE PROPERLY TORQUED - SIGNED BY LICENSE CONTRACTOR. 9. ALL SWITCHGEAR SHOWN IS TO BE PROVIDED IN NEMA 3R ENCLOSURE UNLESS OTHERWISE INDICATED. 10. ALL COMMUNICATIONS CONDUITS ARE TO HAVE COMMUNICATIONS PULL BOXES ADJACENT TO POWER PULL BOX SHOWN ON PLANS, AND ARE TO TERMINATE IN COMMUNICATION PULL BOXES. KEYNOTES 10 EXISTING GROUNDING ELECTRODE TO REMAIN. O2 EXISTING SDG&E METER SOCKET TO REMAIN. O3 REVISED LOAD ON EXISTING DISTRIBUTION BOARD. QMODIFY NnTFR SECTION TO BE DEMOLISH SEE SHEET E1.00 FOR ADDITIONAL INFORMATIC PROVIDE NEW FEEDER AND CONDUIT SEE SHEET E1.01 FOR ADDITIONAL INFORMATION. PROVIDE 3#1/0 AL, 1#4 AL GND, 4" CO. U PLUMBING CONTRACTOR TO PROVIDE CONTROL CABINET FOR PUMPS, ELECTRICAL CONTRACTOR TO PROVIDE SINGLE POINT OF CONNECTION. SILVERROCK DEVELOPMENT COMPANY, LLC 79-179 AHMANSON LANE, LA QUINTA, CA 92253 Rowan Electric 2778 LOKER AVE WEST, CARLSBAD, CA 92010 0 (760) 692-0700 THE ELECTRICAL DESIGN IS DEPENDANT ON INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND /OR ROWAN ELECTRIC MAKE NO CLAIMS OF THE ACCURACY OR VALIDITY OF THE INFORMATION PROVIDED BY OTHERS THE DESIGNER, ENGINEER, AND OR ROWAN ELECTRIC DISCLAIMS RESPONSIBILITY FOR ANY OVERSIGHTS, ERRORS, OR OMISSIONS Consulting Engineers, Inc. DEVELOP. DESIGN. DELIVER 1044 PIONEER WAY, SUITE E EL CAJON, CA 92020 TEL: 619.334.6020 RBCE JOB #2018- 0048 0 Date Description A 2019-01-11 PERMIT SUBMISSION 1 2019-01-24 CHANGES 2 2019-02-14 CHANGES 3 2019-03-12 PC RESUBMITTAL Seal / Signature Project Name SILVERROCK - SITE Project Number 2018-0048 Description SINGLE LINE DIAGRAM Scale As indicated SINGLE LINE DIAGRAM SCALE: NONE E8n01 © 2015 Gensler