Loading...
PGA West - Coral Mountain TR 34243 BCPR2021-0011 (Plan J-Mod & J)Project Details PROJECT NUMBER City of La _Quinta BCPR2021-0011 Ot T\4F. Description: CORAL MOUNTAIN / PLAN J & J-MOD TRACT CONSTRUCTION PLANS Status: APPROVED Type: BUILDING CONSTRUCTION PLAN REVIEW (WEB) Status Date: Subtype: TRACT RESIDENTIAL Applied: 5/13/2021 Address: 80750 AVENUE 58 Approved: 7/21/2021 City, State, Zip: LA QUINTA,CA92253 Closed: Project Manager: Expired: Details: CORAL MOUNTAIN (TR 34243) / PLAN J & J-MOD TRACT CONSTRUCTION MASTER PLANS FOR THE 2019 CODE CYCLE (SFD x 2). 2,811SF SINGLE FAMILY DWELLINGS - [VB/RES-3/CLASS A-FR/13D] 2019 CALIFORNIA BUILDING CODES. DAYS WE REVIEWS 8 ACTIONS 3 INSPECTIONS CONDITIONS CASE OPEN OPEN COMPLETED A 1 0 • • • • • CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL JAKE FUSON 6/15/2021 6/15/2021 NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL. 2ND PC SUBMITTAL JAKE FUSON 7/6/2021 7/6/2021 RECEIVED EMAIL JAKE FUSON 7/21/2021 7/21/2021 NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND FEE IS READY FOR PAYMENT. NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT AV Construction LLC PO Box 13920 PALM DESERT CA 92255 (760)200-6607 rjones@altaverdebuild ers.com Printed: Wednesday, December 20, 2023 11:16:08 AM 1 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL ARCHITECT PVG ARCHITECTS 44-530 San Pablo Ave Suite 200 CA 92260 (760)200-6607 tatianab@pvgarchitect s.com DEVELOPER AV Construction LLC PO Box 13920 PALM DESERT CA 92255 (760)200-6607 rjones@altaverdebuild ers.com ENGINEER Option One Consulting Engineers 2755 Bristol Street Ste. Costa Mesa CA 92626 (760)200-6607 garym@option-1.com #100 OWNER AV CONSTRUCTION PO BOX 13290 PALM DESERT CA 92255 (760)200-6607 PRIMARY Tatiana Barbuzza San Pablo Ave, 200 Palm Desert CA 92260 (760)200-6607 tatianab@pvgarchitect CONTACT s.com 7 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY HOURLY CHARGE -CITY 101-0000-42600 3 $483.00 $483.00 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM BUILDING STAFF BUILDERS, INC. HOURLY CHARGE - INTERWEST 101-0000-42600 3.5 $437.50 $437.50 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM STRUCTURAL PLAN BUILDERS, INC. REVIEW Total Paid for BUILDING STAFF - PER HOUR: $920.50 $920.50 FIRE STAFF - PER HOUR 101-0000-42420 0.5 $80.50 $80.50 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM BUILDERS, INC. Total Paid for FIRE FEES: $80.50 $80.50 RECORDS MANAGEMENT FEE - 101-0000-42416 0 $21.00 $21.00 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM BUILDERS, INC. MAJOR Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 Printed: Wednesday, December 20, 2023 11:16:08 AM 2 of 8 CENTRALSQUARE Project Details PROJECT NUMBER City of La Quinta BCPR2021-0011 CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM ENHANCEMENT FEE BUILDERS, INC. Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 NEW CONSTRUCTION - 101-0000-42400 0 $644.00 $644.00 7/23/21 R66189 1672 CHECK ALTA VERDE JLIM 5+ RESIDENTIAL UNITS BUILDERS, INC. Total Paid for ZONING CLEARANCE - PLANNING PLAN $644.00 $644.00 CHECK: 11 •ll Fill I LVIV INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED RESULT DATE REMARKS NOTES RETURNED REVIEW TYPE REVIEWER SENT DATE DUE DATE STATUS REMARKS NOTES DATE 1ST BLDG INTERWEST 5/13/2021 5/27/2021 6/1/2021 REVISIONS REQUIRED COMPLETE (2WK) 1ST BLDG NS (3WK) JAKE FUSON 5/13/2021 6/4/2021 6/15/2021 REVISIONS REQUIRED SEE 1ST REVIEW COMPLETE CORRECTION LIST. 1ST FIRE (2WK) 5/13/2021 5/27/2021 5/27/2021 APPROVED HEOHL ATTACHMENTS 1ST PERMIT PERMIT TECH 5/13/2021 5/14/2021 5/13/2021 COMPLETE TECHNICIAN (1DAY) BUCKET 1ST PLANNING SIJIFREDO 5/13/2021 5/27/2021 5/27/2021 READY FOR APPROVAL (2WK) FERNANDEZ PRIOR TO BUILDING PERMIT ISSUANCE, NEED 1ST PUBLIC WORKS AMY YU 5/13/2021 5/27/2021 6/3/2021 APPROVED- APPROVAL OF PRECISE GRADING PLANS AND PAD (2WK) CONDITIONS CERT 2ND BLDG NS (2WK) JAKE FUSON 7/6/2021 7/13/2021 7/21/2021 APPROVED Printed: Wednesday, December 20, 2023 11:16:08 AM 3 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 2ND BLDG STR I INTERWEST I 7/6/2021 I 7/13/2021 7/21/2021 I APPROVED (1WK) SEE ATTACHED INVOICE. Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED PLAN J - 1ST SUBMITTAL 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor MOUNTAIN J PLAN - 1 ENERGY REPORT TITLE 24.pdf PLAN J -MOD - 1ST 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor SUBMITTAL MOUNTAIN J-MOD 1 STRUCTURAL PLAN -STRUCTURAL CALCULATIONS CALCS.pdf PLAN J-MOD - 1ST 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor SUBMITTAL ENERGY MOUNTAIN J-MOD 1 REPORT PLAN - TITLE 24.pdf 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor 1ST SUBMITTAL - PLAN MOUNTAIN - FULL SET J 1 SET - J-MOD.pdf 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor 1ST SUBMITTAL - MOUNTAIN - GEO 1 GEOTECHNICAL UPDATE TECH.pdf PLAN J - 1ST SUBMITTAL 1ST SUBMITTAL - CORAL DOC 5/13/2021 EtrakitContractor STRUCTURAL MOUNTAIN J PLAN - 1 CALCULATIONS STRUCTURAL CALCS.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J CORAL MOUNTAIN J 1 and J-MOD PLAN - and J-MOD PLAN - GEOTECH REPORT GEOTECH REPORT.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J CORAL MOUNTAIN J 1 PLAN - GEOTECH PLAN - GEOTECH CONFORMANCE CONFORMANCE.pdf Printed: Wednesday, December 20, 2023 11:16:08 AM 4 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J CORAL MOUNTAIN J 1 PLAN - TITLE 24 PLAN -TITLE 24.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J- CORAL MOUNTAIN J- 1 MOD PLAN - GEOTECH MOD PLAN - GEOTECH CONFORMANCE CONFORMANCE.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J- CORAL MOUNTAIN J 1 MOD PLAN -TITLE MOD PLAN - TITLE 24 24. ESR-1962_ThermalStar- DOC 7/6/2021 EtrakitContractor ICC Report ESR 1962 1 TG.pdf ESR- DOC 7/6/2021 EtrakitContractor ICC Report ESR 1194 1194_Omega_Diamond 1 Wall.pdf DOC 7/6/2021 EtrakitContractor ICC Report ESR 3174 ESR-3174_Hunter1 panels.pdf Plan J - Truss Book1 DOC 7/6/2021 EtrakitContractor Plan J -Truss Book 1of2 1of2.pdf Plan J - Truss Book1 DOC 7/6/2021 EtrakitContractor Plan J -Truss Book 2of2 2of2.pdf DOC 7/6/2021 EtrakitContractor Plan J-MOD - Truss Book Plan J-MOD - Truss Book 1 1of2 1of2.pdf Plan J-MOD - Truss Book Plan J-MOD - Truss Book DOC 7/6/2021 EtrakitContractor 1 2of2 2of2.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/6/2021 EtrakitContractor CORAL MOUNTAIN J CORAL MOUNTAIN J 1 and J-MOD PLAN - and J-MOD PLAN - RESPONSE RESPONSE.pdf Printed: Wednesday, December 20, 2023 11:16:08 AM 5 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/15/2021 EtrakitContractor CORAL MOUNTAIN J CORAL MOUNTAIN J 1 PLAN - FULL SET PLAN -FULL SET_2.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 7/15/2021 EtrakitContractor CORAL MOUNTAIN J- CORAL MOUNTAIN J- 1 MOD PLAN -FULL MOD PLAN - FULL SET SET_2.pdf RES La Quinta- DOC 6/1/2021 INTERWEST 1ST REVIEW INTERWEST BCPR2021-0011-PC1- 0 COMMENTS Coral Mtn PGA West Model J.docx 1ST REVIEW INTERWEST La Quinta - LAQ21-0037- DOC 6/1/2021 INTERWEST 0 INVOICE 69421.pdf BCPR2021-0011 - 1ST DOC 6/15/2021 JAKE FUSON 1ST REVIEW COMPLETE REVIEW COMPLETE 1 CORRECTION LIST CORRECTION LIST.pdf BCPR2021-0011 - 2ND DOC 7/21/2021 JAKE FUSON 2ND REVIEW REVIEW INTERWEST 1 INTERWEST INVOICE INVOICE.pdf 2ND REVIEW BCPR2021-0011 - 2ND DOC 7/21/2021 JAKE FUSON INTERWEST REVIEW INTERWEST 1 TRANSMITTAL TRANS MITTAL.docx BCPR2021-0011 - PLAN J DOC 7/21/2021 JAKE FUSON PLAN J - APPROVED - APPROVED ENERGY 1 ENERGY REPORT REPORT.pdf BCPR2021-0011 - PLAN J PLAN J - APPROVED DOC 7/21/2021 JAKE FUSON GEOTECHNICAL REVIEW -APPROVED 1 GEOTECHNICAL REVIEW LETTER LETTER.pdf Printed: Wednesday, December 20, 2023 11:16:08 AM 6 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED BCPR2021-0011 - PLAN J PLAN J - APPROVED DOC 7/21/2021 JAKE FUSON STRUCTURAL -APPROVED 1 STRUCTURAL CALCULATIONS CALCULATIONS.pdf BCPR2021-0011 - PLAN J DOC 7/21/2021 JAKE FUSON PLAN J - APPROVED - APPROVED TRUSS 1 TRUSS CALCULATIONS CALCULATIONS.pdf BCPR2021-0011 - PLAN J PLAN J AND J-MOD- DOC 7/21/2021 JAKE FUSON APPROVED AND J-MOD- APPROVED 1 GEOTECHNICAL GEOTECHNICAL REPORT REPORT.pdf PLAN J-MOD - BCPR2021-0011 - PLAN DOC 7/21/2021 JAKE FUSON APPROVED ENERGY J-MOD - APPROVED 1 REPORT ENERGY REPORT.pdf PLAN J-MOD - BCPR2021-0011 - PLAN DOC 7/21/2021 JAKE FUSON APPROVED J-MOD - APPROVED 1 GEOTECHNICAL REVIEW GEOTECHNICAL REVIEW LETTER LETTER.pdf PLAN J-MOD - BCPR2021-0011 - PLAN DOC 7/21/2021 JAKE FUSON APPROVED J-MOD - APPROVED 1 STRUCTURAL STRUCTURAL CALCULATIONS CALCULATIONS.pdf BCPR2021-0011 - PLAN PLAN J-MOD - DOC 7/21/2021 JAKE FUSON APPROVED TRUSS J-MOD -APPROVED 1 TRUSS CALCULATIONS CALCULATIONS.pdf BCPR2021-0011 - PLAN DOC 7/21/2021 JAKE FUSON PLAN J-MOD J-MOD - APPROVED 1 APPROVED PLAN SET PLAN SET1.pdf BCPR2021-0011 - PLAN J DOC 7/21/2021 JAKE FUSON PLAN J - APPROVED - APPROVED PLAN 1 PLAN SET SET1.pdf Printed: Wednesday, December 20, 2023 11:16:08 AM 7 of 8 CENTRALSQUARE !� ylProject Details PROJECT NUMBER City of La Quinta BCPR2021-0011 Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 7/21/2021 JAKE FUSON PLAN J TAKEOFF SHEET BCPR2021-0011 - PLAN J 1 TAKEOFF SHEET.pdf BCPR2021-0011 - PLAN DOC 7/21/2021 JAKE FUSON PLAN J-MOD TAKEOFF J-MOD TAKEOFF 1 SHEET SHEET.pdf DOC 10/7/2021 JAKE FUSON PLAN J TAKEOFF SHEET BCPR2021-0011 - PLAN J 0 TAKEOFF SHEET_1.pdf BCPR2021-0011 - PLAN DOC 10/7/2021 JAKE FUSON PLAN J-MOD TAKEOFF J-MOD TAKEOFF 0 SHEET SHEET_1.pdf BCPR2021-0011 - FIRE DOC 5/27/2021 KOHL HETRICK FIRE CONDITIONS OF CONDITIONS OF 1 APPROVAL APPROVAL.pdf Printed: Wednesday, December 20, 2023 11:16:08 AM 8 of 8 CENTRALSQUARE CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT uCv BILL WEISER — FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org May 27, 2021 AV Construction LLC PO Box 13920 Palm Desert, CA 92255 Re: Residential Building Tract Plans - Fire Plan Review — CORAL MOUNTAIN @ PGA WEST (TR30487) — PLAN J, J-MODERN BCPR2021-0011 / 80750 AVENUE 58, LA QUINTA, CA 92253 The building plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Fire Department approval is based upon the 2019 CBC/CRC requirements for R-3/U occupancies in a planned/tract community. TRACT ACCESS & WATER REQUIREMENTS: ACCESS Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, La Quinta Municipal Code and Riverside County Fire Department Standards. 1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs and/or red painted curbs. 2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key -switch access. Automatic gates shall also have Opticom IR receivers. 3) Approved street signs shall be installed and visible. 4) No Traffic Calming Devices shall be installed. *Future/proposed traffic calming devices require approval by the Office of the Fire Marshal. WATER 1) Fire hydrants shall be installed within 600 feet hose -lay length of the proposed residential units. 2) An observable minimum fire flow shall be present upon testing. 3) Fire hydrant caps shall be in place and marked in accordance with local requirements. 4) Blue roadway reflector shall be installed in the completed roadway to identify the location of all fire hydrants. 5) Hydrant roadway valve boxes shall have their coverplate or lid exposed and easily accessible. PRIOR TO PERMIT RELEASE INSPECTION 1) Individual Tract Home (Production) permits will not be released until a Tract Access/Water inspection has been completed for the affected phase or groupingof lots. Applicant/Contractor shall be responsible for contacting the Office of the Fire Marshal to schedule inspections. Request for inspections are to be made at least 48 hours in advance and may be arranged by calling 760-777-7131. DEFERRED SUBMITTALS REQUIRED 1) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections. a. Residential Fire Sprinkler permits may be applied for as Master Plan Types. A single Fire Sprinkler Master Plan permit for each different plan type may be individually applied for. Coordinate with the La Quinta Permit Technicians for appropriate application and fee process. GENERAL CONDITIONS 1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be posted at the driveway entrance and maintained visible. 2) All HOA and Private landscaping shall maintain a minum 3-feet radius clearance around the circumference of fire protection equipment, that includes fire hydrants. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist TR 34243 PROJECT DESCRIPTION CORAL MOUNTAIN - PLAN ]-MOD APPLICATION BCPR2021-0011 VALID UNITL DATE 12/31/2023 Mechanical Units New Construction FURNACE 2 HEATER CONDITIONED/AC (SF) 2,811 APPLIANCE (ALT/ADD) GARAGE/UNCOND (SF) 477 COMPRESSOR 2 PATIO/COVERED (SF) 325 AIR HANDLER FIRE SPRINKLER (SF) 3,288 EVAP COOLER VENT FAN 7 CODE EDITION 2019 EXHAUST HOOD 1 CONSTRUCTION TYPE VB MISC MECHANICAL GOOD YES / NO NUMBER OF FLOORS 1 Electrical Units NUMBER OF BEDROOMS 3-Jan NUMBER OF UNITS 1 NEW ELECTRICAL (SF; 3,288 OCCUPANT LOAD and/or OCCUPANCY R-3/U RECEP/SWITCH/LIGHT MSHCP (DU/ACRE) 3.7 plus (DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE) APPLIANCE - RES APPLIANCE - NONRES Options POWER APPARATUS SIGNS SERVICE TEMPORARY SERVICE 1 MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units Grading FIXTURE/TRAP 15 SEWER 1 TRACT 1 SEPTIC CUSTOM HOME <=7KSF ROOF DRAIN 3 CUSTOM HOME >7KSF WATER HEATER 1 GREASE INTERCEPTOR WATER PIPING 1 BACKFLOW GAS OUTLETS 8 REVISED:5/15/2019 TR 34243 APPLICATION BCPR2021-0011 PROJECT DESCRIPTION VALID UNITL DATE 12/31/2023 CORAL MOUNTAIN - PLAN ]-MOD Mechanical Units New Construction FURNACE 2 HEATER CONDITIONED/AC (SF) 2,811 APPLIANCE (ALT/ADD) GARAGE/UNCOND (SF) 477 COMPRESSOR 2 PATIO/COVERED (SF) 140 AIR HANDLER FIRE SPRINKLER (SF) 3,288 EVAP COOLER VENT FAN 7 CODE EDITION 2019 EXHAUST HOOD 1 CONSTRUCTION TYPE VB MISC MECHANICAL GOOD *ES / NO NUMBER OF FLOORS 1 Electrical Units NUMBER OF BEDROOMS 3-Jan NUMBER OF UNITS 1 NEW ELECTRICAL (SF; 3,288 OCCUPANT LOAD and/or OCCUPANCY R-3/U RECEP/SWITCH/LIGHT MSHCP (DU/ACRE) 3.7 plus (DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE) APPLIANCE - RES APPLIANCE - NONRES Options POWER APPARATUS Optional Pool Structure SIGNS Add: SERVICE 159sf Patio/Covered Area TEMPORARY SERVICE 1 159sf New Electrical MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units Grading FIXTURE/TRAP 15 SEWER 1 TRACT 1 SEPTIC CUSTOM HOME <=7KSF ROOF DRAIN 3 CUSTOM HOME >7KSF WATER HEATER 1 GREASE INTERCEPTOR WATER PIPING 1 BACKFLOW GAS OUTLETS 8 REVISED:5/15/2019 TR 34243 PROJECT DESCRIPTION CORAL MOUNTAIN - PLAN J APPLICATION BCPR2021-0011 VALID UNITL DATE 12/31/2023 Mechanical Units New Construction FURNACE 2 HEATER CONDITIONED/AC (SF) 2,811 APPLIANCE (ALT/ADD) GARAGE/UNCOND (SF) 477 COMPRESSOR 2 PATIO/COVERED (SF) 160 AIR HANDLER FIRE SPRINKLER (SF) 3,288 EVAP COOLER VENT FAN 7 CODE EDITION 2019 EXHAUST HOOD 1 CONSTRUCTION TYPE VB MISC MECHANICAL GOOD YES / NO NUMBER OF FLOORS 1 Electrical Units NUMBER OF BEDROOMS 3-Jan NUMBER OF UNITS 1 NEW ELECTRICAL (SF; 3,288 OCCUPANT LOAD and/or OCCUPANCY R-3/U RECEP/SWITCH/LIGHT MSHCP (DU/ACRE) 3.7 plus (DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE) APPLIANCE - RES APPLIANCE - NONRES Options POWER APPARATUS SIGNS SERVICE TEMPORARY SERVICE 1 MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units Grading FIXTURE/TRAP 15 SEWER 1 TRACT 1 SEPTIC CUSTOM HOME <=7KSF ROOF DRAIN 3 CUSTOM HOME >7KSF WATER HEATER 1 GREASE INTERCEPTOR WATER PIPING 1 BACKFLOW GAS OUTLETS 8 REVISED:5/15/2019 TR 34243 APPLICATION BCPR2021-0011 PROJECT DESCRIPTION VALID UNITL DATE 12/31/2023 CORAL MOUNTAIN - PLAN J Mechanical Units New Construction FURNACE 2 HEATER CONDITIONED/AC (SF) 2,811 APPLIANCE (ALT/ADD) GARAGE/UNCOND (SF) 477 COMPRESSOR 2 PATIO/COVERED (SF) 300 AIR HANDLER FIRE SPRINKLER (SF) 3,288 EVAP COOLER VENT FAN 7 CODE EDITION 2019 EXHAUST HOOD 1 CONSTRUCTION TYPE VB MISC MECHANICAL GOOD *ES / NO NUMBER OF FLOORS 1 Electrical Units NUMBER OF BEDROOMS 3-Jan NUMBER OF UNITS 1 NEW ELECTRICAL (SF; 3,288 OCCUPANT LOAD and/or OCCUPANCY R-3/1-1 RECEP/SWITCH/LIGHT MSHCP (DU/ACRE) 3.7 plus (DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE) APPLIANCE - RES APPLIANCE - NONRES Options POWER APPARATUS Optional Pool Structure SIGNS Add: SERVICE 159sf Patio/Covered Area TEMPORARY SERVICE 1 159sf New Electrical MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units Grading FIXTURE/TRAP 15 SEWER 1 TRACT 1 SEPTIC CUSTOM HOME <=7KSF ROOF DRAIN 3 CUSTOM HOME >7KSF WATER HEATER 1 GREASE INTERCEPTOR WATER PIPING 1 BACKFLOW GAS OUTLETS 8 REVISED:5/15/2019 ICC-ES Evaluation Report ESR-1194 www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 DIVISION: 09 00 00—FINISHES Section: 09 24 00—Portland Cement Plastering REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC. EVALUATION SUBJECT: OMEGA DIAMOND WALL AND DIAMOND WALL PM INSULATING EXTERIOR STUCCO SYSTEMS 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012 and 2009 International Building Code° (IBC) ■ 2018, 2015, 2012 and 2009 International Residential Code° (I RC) ■ 2013 Abu Dhabi International Building Code (ADIBC)t tThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ■ Structural ■ Durability ■ Fire -resistance -rated construction ■ Types I through IV (noncombustible) construction 2.0 USES The Omega Diamond Wall Insulating Exterior Stucco Systems (Diamond Wall and Diamond Wall PM) are cementitious wall covering systems installed on exterior walls of wood or steel frame, concrete or concrete masonry construction. The systems are alternatives to the exterior wall coverings specified in IBC Chapter 25, and IRC Section R703. The systems are recognized for use in Types I, ll, III, IV, and V construction. When used to construct one -hour fire -resistance -rated wall assemblies, installation must be as described in Section 4.4. When used on walls required to be Type I, II, III, or IV construction, installation must be as described in Section 4.5. Under the 2018, 2015 and 2012 IBC, for Reissued November 2020 This report is subject to renewal November 2021. A Subsidiary of the International Code Council° exteriorwalls on buildings of Type I, II, III, or IV construction, recognition is limited to walls no greater than 40 feet (21.19 m) in height above grade as indicated in 2018, 2015 and 2012 IBC Section 1403.5, except as permitted under Exception 2 of 2018 IBC Section 1402.5 (2015 IBC Section 1403.5). 3.0 DESCRIPTION 3.1 General: The Omega Diamond Wall and Diamond Wall PM insulating exterior stucco systems are proprietary mixtures of portland cement, sand, fibers, water and proprietary ingredients reinforced with wire fabric or metal lath, and applied to substrates of expanded polystyrene (EPS), extruded polystyrene (XPS) and polyisocya n u rate foam plastic insulation boards, Fome-Cor Board, concrete or concrete masonry, wood structural panels, fiberboard, and gypsum sheathing. The systems may be installed on exterior walls of wood -framed, steel -framed, concrete or concrete masonry construction. 3.2 Materials: 3.2.1 Diamond Wall Stucco: The stucco is a factory - prepared mixture of Type I or II Portland cement complying with ASTM C150, chopped glass fibers and proprietary additives. The mixture is packaged in 80-pound (36 kg) bags. Approximately 41/2 to 7 gallons (17 to 26.5 L) of water and between 160 to 240 pounds (72 to 109 kg) of sand are added to each bag in the field, and mixing is done in accordance with the manufacturer's recommendations. As an alternative, the Diamond Wall PM system allows for the substitution of up to one-half the amount of water with equal parts of the Omega Diamond Wall PM Admix, a liquid admixture composed of acrylic polymers and modifiers. The PM Admix is packaged in 31/2-gallon (13.25 L) pails. The admixture has a shelf life of approximately two years when protected from extreme sunlight and freezing for extended periods. Storage temperatures must be between 40°F and 110°F (4°C and 39°C). The Diamond Wall PM system requires the inspections specified in Section 4.6.1. 3.2.2 Sand: Sand must be clean and free from deleterious amounts of loam, clay, silt, soluble salts and organic matter. Sampling and testing must comply with ASTM C144 or C897. Sand must be graded in accordance with ASTM C144 or C897 or within the following limits: ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as R to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2020 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 12 ESR-1194 1 Most Widely Accepted and Trusted Page 2 of 12 RETAINED ON U.S. STANDARD SIEVE PERCENT RETAINED BY WEIGHT # 2 PERCENT Natural Sand Min. / Max. Manufactured Sand Min. / Max. No.4 0/0 0/0 No. 8 0 /10 0 / 10 No. 16 10/40 10/40 No. 30 30 / 65 30 / 65 No. 50 1 70 / 90 60 / 80 No. 100 1 95 / 100 75 / 90 3.2.3 Insulation Board: 3.2.3.1 EPS Insulation Board: EPS board must have a nominal density of 1.5 pounds per cubic foot (24 kg/m3), a flame -spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84 or UL723; and must comply with ASTM C578 as Type Il. All boards must be recognized in a current ICC-ES evaluation report. See Section 7.2 for board identification requirements. Boards installed without sheathing over open framing must be 1 inch to 11/2 inches (25.4 to 38 mm) thick and must be provided with 3/8-inch-high (9.5 mm) tongues with compatible grooves for horizontal joints. See Figure 1 for joint details. Over solid substrates, square -edge foam plastic boards, complying with ASTM C578 as Type I, with a minimum 1/2-inch (12.7 mm) thickness and a minimum nominal density of 1 pcf (16 kg/m3) may be used, except when installation of the foam plastic board is as part of the water -resistive barrier over wood -based sheathing as described in Section 3.2.9.1, which requires 1-inch-thick (25.4 mm) EPS boards with tongue -and -groove edges. When installation is over solid substrates, as described in Section 4.3, the boards must have minimum 1/4-inch-wide- by-1/8-inch-deep (6.4 mm by 3.2 mm) vertical grooves spaced at a maximum of 12 inches (305 mm) on the back face of the boards, as shown in Figure 1 B. As an alternate to the vertical grooves in the foam plastic board, flat -faced boards may be installed over solid substrates provided the Tyvek StuccoWrap water -resistive barrier recognized in ESR-2375 is installed behind the boards. 3.2.3.2 XPS Insulation Board: XPS board must have a nominal density of 1.5 pounds per cubic foot (24 kg/m3), must comply with ASTM C578 as Type IV or V and must be recognized in a current ICC-ES evaluation report. See Section 3.2.3.1 for other details and requirements. As an alternative, DOW Styrofoam Stuccomate brand XPS insulation boards, recognized in ESR-2142 and having a 1-inch (25.4 mm) thickness and a nominal density of 1.3 pounds per cubic foot (21 kg/m3), may also be used. 3.2.3.3 Polyisocyanurate Foam Plastic Board: Polyisocyanurate foam plastic board must comply with ASTM C1289 as Type Il. Polyisocyanurate foam plastic boards must have a nominal density of 2 pounds per cubic foot (32 kg/m3) and a maximum flame -spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84 or UL723. The foam plastic board must be 1 inch to 11/2 inches (25 to 38 mm) thick, have all squared joints installed at horizontal and vertical edges supported by framing or blocking and be limited to nonfire-resistance-rated and combustible construction. All boards must be recognized in a current ICC-ES evaluation report. See Section 7.2 for board identification requirements. Over solid substrates, a square -edge foam plastic board with a minimum thickness Of 1/2 inch (12.7 mm) may be used, with the same requirements set forth in Section 3.2.3.1. 3.2.4 Lath: 3.2.4.1 Wire Fabric Lath: Wire fabric lath must comply with the ICC-ES Acceptance Criteria for Metal Plaster Bases (Lath) (AC191), or be recognized in a current ICC-ES evaluation report. Minimum No. 20 gage [0.035 inch (0.89 mm)], 1-inch galvanized steel, woven - wire fabric must be used. Lath must be furred when applied over all substrates except unbacked foam plastic insulation board. Furring must comply with the following requirements: a. When maximum total coating thickness is 1/2 inch (12.7 mm) or less, the body of the lath must be furred a minimum of 1/8 inch (3.2 mm) from the substrate after installation. b. When total coating thickness is greater than 1/2 inch (12.7 mm), No. 17 gage [0.058 inch (1.47 mm)] by 11/2-inch (38 mm) woven -wire fabric lath must be used. The body of the lath must be furred a minimum of 1/4 inch (6.4 mm) from the substrate after lath installation. 3.2.4.2 Metal Lath: Metal lath must comply with AC191. Furring requirements are as set forth in Section 3.2.4.1. 3.2.5 Fiberboard: Minimum 1/2-inch-thick (12.7 mm), asphalt -impregnated fiberboard must comply with ASTM C208 as Type IV, Grade 1 wall sheathing. 3.2.6 Wood Structural Panel Sheathing: Wood structural panel sheathing must be minimum 5/is-inch-thick (7.9 mm) plywood or OSB for studs spaced 16 inches (406 mm) on center, and must be a minimum 3/8-inch-thick (9.5 mm) plywood or OSB for studs spaced 24 inches (610 mm) on center. Plywood must be exterior -grade or Exposure 1 and comply with U.S. DOC PS-1; and OSB must be Exposure 1 and comply with U.S. DOC PS-2. 3.2.7 Gypsum Board: Water-resistant core -treated gypsum sheathing must comply with ASTM C79 or ASTM C1396. Gypsum wallboard must comply with ASTM C36 or ASTM C1396. Glass mat faced, water-resistant core - treated gypsum sheathing must comply with ASTM C1177 and be recognized in a current ICC-ES evaluation report. Water-resistant exterior fiber -reinforced gypsum sheathing must comply with ASTM C1278 and be recognized in a current ICC-ES evaluation report. 3.2.8 Caulking: Caulking materials must be either acrylic latex complying with ASTM C834, or polyurethane, polyurethane modified, polysulfide, or silyl-terminated polyether elastomeric sealant complying with ASTM C920. 3.2.9 Weather Protection: 3.2.9.1 Water -resistive Barrier: A water -resistive barrier is required and must comply with 2018 IBC Section 1403.2 (2015, 2012 and 2009 IBC Section 1404.2) or IRC Section R703.2, as applicable. Minimum No. 15 asphalt nonperforated felt complying as Type I in accordance with ASTM D226 (IBC or IRC); or material recognized in a current ICC-ES evaluation report as equivalent to ASTM D226, Type I, is required. When applied over any wood -based sheathing, the barrier must be either: (a) minimum of two layers of Grade D kraft building paper as set forth in 2012 and 2009 IBC Section 2510.6, or 2018 and 2015 IRC Section R703.7.3 or 2012 and 2009 IRC Section R703.6.3, as applicable, or an equivalent recognized in a current ICC-ES evaluation report; or (b) one layer of EPS or XPS insulation board, having horizontal tongue -and -groove edges as described in Section 3.2.3.1, over one layer of Grade D kraft building paper having a minimum water -resistance rating of 60 minutes, or an equivalent recognized in a current ICC-ES evaluation report. ESR-1194 1 Most Widely Accepted and Trusted Page 3 of 12 When application is over gypsum sheathing, Fome-Cor Board, recognized as complying with ICC-ES AC38 and installed in accordance with evaluation report ESR-1614, may be used as the water -resistive barrier. When Tyvek StuccoWrap is used as the water -resistive barrier, the grooves in the insulation board described in Section 3.2.3.1 are not required. The Tyvek StuccoWrap must be installed in accordance with ESR-2375. 3.2.9.2 Vapor Retarder: Protection against condensation must be provided in accordance with 2018 IBC Section 1404.3 (2015, 2012 and 2009 IBC Section 1405.3). Under the 2018, 2015 and 2012 IRC, a vapor retarder must be provided in accordance with IRC Section R702.7. Under the 2009 IRC, a vapor retarder must be provided in accordance with IRC Section R601.3, unless its omission is permitted under the exceptions in IRC Section R601.3. 3.2.10 Flashing: Flashing complying with 2018 IBC Section 1404.4 (2015, 2012 and 2009 IBC Section 1405.4), or 2018 and 2015 IRC Section R703.4 or 2012 and 2009 IRC Section R703.8, must be provided. Where flexible flashing is used, it must be a self -adhering, flexible rubberized asphalt and polyethylene material, a minimum of 0.020 inch (0.51 mm) thick, shingle -lapped with the water -resistive barrier. Rigid flashings must be sloped towards the exterior, with an upturned leg on the interior side and at the ends, and must extend beyond the surface of the exterior wall. 3.2.11 Trim and Accessories: All trim, weep screeds and corner reinforcement must be corrosion -resistant. 4.0 INSTALLATION 4.1 General: The exterior cementitious coating must be applied by hand -troweling or machine -spraying, in one coat or two coats, to a minimum 3/8-inch (9.5 mm) thickness, unless noted otherwise. Nominal thickness around penetrations is 3/8 inch (9.5 mm), backed by framing or blocking. The lath must be embedded in the minimum coating thickness and therefore cannot be exposed. The finish coat must be applied in accordance with Omega Products International, Inc. instructions. Flashing, corner reinforcement, metal trim and weep screeds must be installed as shown in Figure 2. The coating must be applied at ambient air temperatures of 40°F to 120°F (4°C to 49°C) by applicators approved by Omega Products International, Inc. The water -resistive barrier must be applied as set forth in Section 3.2.9.1. An installation card, such as that shown in Figure 3, must be on the jobsite, with the name of the applicator and the product to be used, before any water -resistive barrier or exterior sheathing is installed. See Section 5.6. 4.2 Application over Open Framing: 4.2.1 Foam Plastic Insulation Boards: The water - resistive barrier must be placed over open wood studs spaced a maximum of 24 inches (610 mm) on center. The EPS, XPS, or polyisocya nu rate board, as described, respectively, in Section 3.2.3.1, 3.2.3.2, or 3.2.3.3, must be attached using galvanized staples, roofing nails, or screws. Vertical butt joints must be staggered at least one stud space from adjacent courses, and must occur directly over studs. DOW Styrofoam Stuccomate brand XPS, 1-inch- thick (25.4 mm) insulation boards, recognized in ESR-2142, may be installed with vertical edges located between framing members, provided the vertical edges are tongue -and -groove and provided the joints between adjacent courses are staggered a minimum of one stud space. The lath must then be applied tightly over the foam plastic insulation board, with 11/2-inch (38 mm) end and side laps, and fastened through the insulation board and water -resistive barrier to wood studs, sills and plates using No. 11 gage galvanized roofing nails or No. 16 gage corrosion -resistant staples spaced a maximum of 6 inches (152 mm) on center with a minimum 1-inch (25 mm) penetration into the studs. Staples must have a minimum crown width Of inch (11.1 mm). The wood species must have a minimum specific gravity of 0.42. Care must be taken to avoid overdriving fasteners. The Omega Diamond Wall coating system may also be applied to minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs spaced a maximum of 24 inches (610 mm) on center. Lath must be applied tightly over the foam plastic board and must be fastened through the board and water - resistive barrier to the metal studs, using minimum No. 8, Type S, corrosion -resistant, drywall screws with 1-inch- diameter (25 mm) washers or No. 8 corrosion -resistant screws having 3/8-inch-diameter (9.5 mm) pan heads, at 7 inches (178 mm) on center to all studs and track. Screws must penetrate the studs a minimum Of inch (12.7 mm). Wall bracing in accordance with 2018 and 2015 IBC Section 2308.6, 2012 and 2009 IBC Section 2308.9.3 or 2308.12, IRC Section R602.10 or R602.11, as applicable, or an acceptable alternate, must be provided. Square wall corners and parapet corners must be covered with corner reinforcement. For round wall, bull nose and parapet corners, metal reinforcement is optional when construction is in accordance with Figure 2. Weep screeds must comply with, and be installed at the bottom of the wall in accordance with, IBC Section 2512.1.2, or 2018 and 2015 IRC Section R703.7.2.1, or 2012 and 2009 IRC Section R703.6.2.1, as applicable. Galvanized steel, J-shaped trim pieces must be installed at other areas where insulation board is exposed. See Figure 2 for typical installation details. At windows and doors, flashing as described in Section 3.2.10 is required. Butting J-trim and approved metal edges, when installed, must be flashed as described in Section 3.2.10. Holes for hose bibs, electrical panels and other penetrations of substrate surfaces, except those caused by fasteners, must also be flashed as described in Section 3.2.10. The coating must then be applied as described in Section 4.1. 4.2.2 Fome-Cor Board: Fome-Cor Board, applied in accordance with evaluation report ESR-1614, is permitted to be applied to wood studs having a minimum specific gravity of 0.50 spaced a maximum of 16 inches (406 mm) on center, followed by 11/2-inch (38.1 mm) by No. 17 gage woven wire lath lapped 2 inches (51 mm). The lath must be secured through the Fome-Cor Board to the studs using 1-inch-crown (25 mm), No. 16 gage staples of sufficient leg length to penetrate studs a minimum of 1 inch (25 mm). The coating must be applied as described in Section 4.1 to a minimum 5/8-inch (15.9 mm) thickness. Alternately, the base coat must be a minimum Of inch (12.7 mm) thick and must be cured in accordance with Section 4.6.3. The finish coat must then be applied over the cured base coat. Additional installation requirements are as noted in Section 4.2.1. 4.3 Application over Solid Substrates: 4.3.1 Fiberboard: Minimum 1/2-inch-thick (12.7 mm) fiberboard, as described in Section 3.2.5, must be installed directly to wood studs or minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs spaced a maximum of 24 inches (610 mm) on center. The fiberboard must be temporarily held in place using corrosion -resistant staples or roofing nails for wood studs or self -drilling tapping ESR-1194 1 Most Widely Accepted and Trusted Page 4 of 12 screws for steel studs. A water -resistive barrier must be applied over the fiberboard under the conditions set forth in Section 3.2.9.1 prior to installation of the lath or optional foam board. When the optional insulation boards are used, the foam plastic boards must have vertical grooves as described in Section 3.2.3, or flat -faced foam plastic boards may be used provided the water -resistive barrier is Tyvek StuccoWrap, as described in Section 3.2.9.1. When grooved foam plastic boards are used, the grooves must face the water -resistive barrier and must be aligned vertically, but may be offset a maximum of 6 inches (152 mm) from adjacent boards. The lath must then be attached to the studs through the sheathing, with fasteners and spacing as described in Section 4.2.1 or as described for fiberboard in 2018 and 2015 IBC Table 2304.10.1, 2012 and 2009 IBC Table 2304.9.1, or IRC Table R602.3(1), as applicable. Wall bracing in accordance with 2018 and 2015 IBC Section 2308.6, 2012 and 2009 IBC Section 2308.9.3 or 2308.12, or IRC Section R602.10 or R602.11, as applicable, or an acceptable alternate, must be provided. Square wall corners and parapet corners must be covered with metal corner reinforcement. For round wall, bull nose and parapet corners, metal reinforcement is optional when construction is in accordance with Figure 2. Weep screeds must comply with, and be installed at the bottom of the wall in accordance with, IBC Section 2512.1.2 or 2018 and 2015 IRC Section R703.7.2.1, or 2012 and 2009 IRC Section R703.6.2.1, as applicable. Galvanized steel, J-shaped trim pieces must be installed at other areas where insulation board is exposed. See Figure 2 for typical installation details. At windows and doors, flashing as described in Section 3.2.10 is required. Butting J-trim and approved metal edges, when installed, must be flashed as described in Section 3.2.10. Holes for hose bibbs, electrical panels and other penetrations of substrate surfaces, except those caused by fasteners, must also be flashed as described in Section 3.2.10. The coating must then be applied as described in Section 4.1. The fiberboard, optional foam plastic insulation board, lath and coating may be applied to minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs spaced a maximum of 24 inches (610 mm) on center, provided the fasteners and their placement are as set forth in Section 4.2.1 for steel studs. 4.3.2 Wood Structural Panel Sheathing: Wood structural panel sheathing must be applied directly to wood studs under the conditions set forth in Section 3.2.6 and 2018 and 2015 IBC Table 2308.6.3(3), 2012 and 2009 IBC Table 2308.9.3(3), or IRC Table 602.3(3), as applicable. The sheathing must be attached in accordance with 2018 and 2015 IBC Table 2304.10.1, 2012 and 2009 IBC Table 2304.9.1 or IRC Table 602.3(1), as applicable. The water -resistive barrier, optional insulation board, wire fabric lath, and coating must be applied as described in Section 4.3.1 for fiberboard. Installation to minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs spaced a maximum of 24 inches (610 mm) on center, is also as described in Section 4.3.1 for fiberboard. For fastener spacing and gages for lath attachment to wood studs of various species, with wood structural panel sheathing and nominal 1/2-inch-thick (12.7 mm) insulation board, see Table 1. For fastener spacing and gages for lath attachment to wood structural panel sheathing and wood studs of various species, having a nominal 1-inch-thick (25 mm) insulation board, see Table 2. 4.3.3 Gypsum Sheathing: Minimum 1/2-inch-thick (12.7 mm), water-resistant core -treated gypsum sheathing, described in Section 3.2.7, must be installed directly over wood studs spaced a maximum of 24 inches (610 mm) on center. Gypsum sheathing must be fastened in accordance with IBC Table 2508.1 or IRC Table R702.3.5, as applicable. Glass mat -faced, water-resistant core -treated gypsum sheathing or water-resistant exterior fiber - reinforced gypsum sheathing, described in Section 3.2.7, must be fastened in accordance with their ICC-ES evaluation report. The gypsum sheathing may also be applied to minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs spaced a maximum of 24 inches (610 mm) on center, provided the fasteners and their placement are as set forth in Section 4.2.1 for steel studs. A water -resistive barrier, as described in Section 3.2.9.1, must be applied over the gypsum sheathing before application of lath or optional insulation board. The water - resistive barrier, optional insulation board, wire fabric lath and coating must be applied as described in Section 4.3.1 for fiberboard. 4.3.4 Concrete and Masonry: Surface preparation must be in accordance with IBC Section 2510.7. Surface must be clean, free of dust and other particles, and sufficiently damp to ensure proper bonding. The Diamond Wall coating is applied directly to the prepared surface at a minimum thickness of 1/8 inch (9.5 mm), in accordance with applicable provisions of Section 4.1. 4.4 One -hour Fire -resistance -rated Assemblies: The assemblies described in this section are rated for exposure to fire from both sides, unless otherwise noted. 4.4.1 First Assembly: 4.4.1.1 Interior Face: One layer of 5/8-inch-thick (15.9 mm), Type X gypsum wallboard, water-resistant backer board or veneer base, complying with ASTM C36 or ASTM C1396, must be applied parallel or at right angles to the interior face of 2-by-4 wood studs spaced a maximum of 24 inches (610 mm) on center. The gypsum board must be attached using 11/8-inch-long (48 mm) 6d coated gypsum wallboard nails, complying with ASTM C514, having 1/4-inch-diameter (6.4 mm) heads, at 7 inches (178 mm) on center to studs, plates and blocking. All gypsum board joints must be backed with minimum 2-by-4 wood framing and taped and treated with joint compound in accordance with ASTM C840 or GA216. Fastener heads must also be treated with joint compound in accordance with ASTM C840 or GA216. 4.4.1.2 Exterior Face: One layer of minimum 5/8-inch- thick (15.9 mm), Type X, water-resistant core gypsum sheathing, 48 inches (1219 mm) wide, must be applied vertically to studs using No. 11 gage, galvanized roofing nails having 7/16- or 1/2-inch diameter (11.1 or 12.7 mm) heads, at 4 inches (102 mm) on center at board edges and 7 inches (178 mm) on center at intermediate studs. The sheathing must be nailed to top and bottom plates at 7 inches (178 mm) on center. A water -resistive barrier must be provided over the sheathing. The lath and wall coating must then be applied without insulation board as described in Section 4.2. 4.4.1.3 Axial Design: Axial loads applied to the wall assembly must be limited to the lesser of the following: The wood stud axial design stress for the wall assembly calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of ANSI AF&PA NDS-05 (2009 IBC and IRC) is limited to 0.78 F'c. 2. The maximum stress must not exceed 0.78 F'� at a maximum slenderness ratio (hld) of 33. ESR-1194 1 Most Widely Accepted and Trusted Page 5 of 12 4.4.2 Second Assembly (Limited Load -bearing): 4.4.2.1 Interior Face: One layer of 5/8-inch-thick (15.9 mm), Type X gypsum wallboard, complying with ASTM C36 or ASTM C1396, must be applied horizontally to the interior face of 2-by-4 wood studs spaced a maximum of 16 inches (406 mm) on center. The wallboard must be fastened to studs using 5d gypsum wallboard nails complying with ASTM C514, having minimum 15/64-inch- diameter (6 mm) heads, at 6 inches (152 mm) on center to studs, plates and sills. All vertical wallboard joints must be backed with minimum 2-by-4 wood framing, and taped and treated with joint compound in accordance with ASTM C840 or GA216. Fastener heads must also be treated with joint compound in accordance with ASTM C840 or GA216. Mineral wool insulation batts, R-13, 35/8 inches (92 mm) thick and having a minimum 1.97 pcf (31.56 kg/m3) density, must be placed in the cavities between studs, and secured to studs. 4.4.2.2 Exterior Face: A water -resistive barrier must be applied over the exterior face of wood studs in accordance with Section 3.2.9.1. One -inch -thick (25 mm), 1.5 pcf density (24 kg/m3) EPS insulation board must be applied in accordance with Section 4.2, followed by 1-inch (25 mm) by No. 20 gage woven -wire lath. The lath must be fastened through the EPS insulation board to studs and plates at 6 inches (152 mm) on center as required by Section 4.2.1. Lath overlaps must be a minimum of 2 inches (51 mm). The Diamond Wall coating must then be applied to the lath in accordance with Section 4.1. 4.4.2.3 Axial Design: The allowable axial loading for this system is limited to the least of the following: 1. 1100 pounds (4893 N) per stud. 2. A maximum of 58 percent of the load calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 3. Design stress of 0.78 F'� calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 4. Design stress of 0.78 F'c at a maximum slenderness ratio (hld) of 33 calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 4.4.3 Third Assembly (Limited Load -bearing): 4.4.3.1 Interior Face: One layer of 5/8-inch-thick (15.9 mm), Type X gypsum wallboard, complying with ASTM C36 or ASTM C1396, must be applied horizontally or vertically to the interior face of 2-by-4 or 2-by-6 wood studs spaced a maximum of 24 inches (610 mm) on center. The wallboard must be fastened to the studs and perimeter framing using 0.100-inch-diameter (2.54 mm) steel cup head nails or No. 6 bugle head screws, 15/8-inch- long (41.3 mm), having minimum head diameters of 0.300 inch (7.62 mm), and spaced a maximum of 8 inches (203 mm) on center. All wallboard joints must be taped and treated with joint compound in accordance with ASTM C840 or GA216. All vertical wallboard joints must be backed with minimum 2-by-4 or 2-by-6 wood framing, and taped and treated with joint compound in accordance with ASTM C840 or GA216. Insulation batts, R-11, measuring 31/2 inches thick(89 mm) for 2-by4 studs, or R-19, measuring 61/4 inches (159 mm) for 2-by-6 studs, must be placed in the cavities between the framing and fastened to the framing. The insulation may be either fiberglass insulation batts with a minimum density of 0.62 pcf (9.93 kg/m'), or kraft-paper-faced fiberglass insulation batts with a minimum density of 0.65 pcf (10.41 kg/m'). 4.4.3.2 Exterior Face: A water -resistive barrier must be applied over the exterior face of wood framing in accordance with Section 3.2.9.1. One -inch -thick (25 mm), 1.5 pcf density (24 kg/m3), tongue -and -groove EPS insulation boards, or DOW Styrofoam Stuccomate brand XPS insulation boards recognized in ESR-2142 and described in Section 3.2.3.2 must be attached to the studs and perimeter framing in accordance with Section 4.2. All vertical joints in the insulation board must occur over studs. The insulation board must be followed by lath, as described in Section 3.2.4, fastened through the insulation boards to the studs and perimeter framing using 2-inch- long (51 mm), No. 16 gage galvanized staples, having 15/16-inch (23.8 mm) crowns, or minimum 21/4-inch-long (31.7 mm), 0.125-inch-diameter (3.18 mm) nails having minimum head diameters of 0.355 inch (9.02 mm). Fasteners must be spaced 6 inches (152 mm) on center. The Diamond Wall coating must then be applied to the lath in accordance with Section 4.1, at a minimum thickness of 3/8 inch (9.5 mm). 4.4.3.3 Axial Design (2-by-4 Wood Construction): The allowable axial loading for this system is limited to the least of the following: 1. 1,100 pounds (4893 N) per stud. 2. A maximum of 51.3 percent of the load calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 3. Design stress of 0.78 F', calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 4. Design stress of 0.78 F', at a maximum slenderness ratio (le/d) of 33 calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-97 05 (2009 IBC and IRC). 4.4.3.4 Axial Design (2-by-6 Wood Construction): The allowable axial loading for this system is limited to the least of the following: 1. 3,000 pounds (13,500 N) per stud up to 10 feet high or 1,100 pounds (4,893 N) per stud for greater heights. 2. A maximum of 44.7 percent of the load calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 3. Design stress of 0.78 F'c calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-05 (2009 IBC and IRC). 4. Design stress of 0.78 F'c at a maximum slenderness ratio (le/d) of 33 calculated in accordance with Sections 3.6 and 3.7 of ANSI AWC NDS (2018, 2015 and 2012 IBC and IRC), or Sections 3.6 and 3.7 of the ANSI/AF&PA NDS-97 05 (2009 IBC and IRC). 4.4.4 Fourth Assembly (Limited Load -bearing): 4.4.4.1 Interior Face: As described in Section 4.4.3.1. 4.4.4.2 Exterior Face: One layer of minimum 7/16-inch- thick (11.1 mm) OSB, one layer of minimum 15/32-inch-thick (11.9 mm) plywood, or one layer of minimum 1/2-inch-thick, ESR-1194 1 Most Widely Accepted and Trusted Page 6 of 12 water-resistant core treated gypsum sheathing complying with ASTM C79 or ASTM C1396, must be applied vertically to the wall, and fastened to the wood studs, sill and plates using 23/8-inch-long (60 mm) 0.113-inch-diameter (2.87 mm), 8d coated sinker nails having minimum head diameters of 0.266 inch (6.76 mm) and spaced a maximum of 8 inches (1219 mm) on center. All vertical joints in the sheathing must occur over studs. The water resistive barrier must be installed as required in Section 3.2.9.1. Lath, as described in Section 3.2.4, must be fastened through the sheathing to the studs with 11/4 inch -long (31.7 mm), 0.125-inch-diameter (3.18 mm) nails having minimum head diameters of 0.355 inch (9.02 mm), or No. 16 gage, corrosion -resistant staples having 15/16-inch (23.8 mm) crowns. The fasteners must be spaced 6 inches (152 mm) on center on the studs and perimeter framing. The Diamond Wall coating must then be applied to the lath in accordance with Section 4.1, at a minimum thickness of 3/8 inch (9.5 mm). 4.4.4.3 Axial Design (2-by-4 Wood Construction): The allowable axial loading for this system is limited as described in Section 4.4.3.3. 4.4.4.4 Axial Design (2-by-6 Wood Construction): The allowable axial loading for this system is limited as described in Section 4.4.3.4. 4.4.5 Fifth Assembly (Limited Load -bearing): 4.4.5.1 Interior Face: As described in Section 4.4.3.1 4.4.5.2 Exterior Face: One layer of minimum 3/8-inch- thick (9.5 mm) OSB, one layer of minimum 13/32-inch-thick (10.3 mm) plywood, or one layer of minimum 1/2-inch-thick, water-resistant core treated gypsum sheathing complying with ASTM C79 or ASTM C1396, must be applied vertically to the wall, and fastened to the wood studs, sill and plates using 23/8-inch-long (60 mm) 0.113-inch-diameter (2.87 mm), 8d coated sinker nails having minimum head diameters of 0.266 inch (6.76 mm) and spaced a maximum of 8 inches (1219 mm) on center. The water -resistive barrier must be installed as required in Section 3.2.9.1. A layer of maximum 1-inch-thick (25.4 mm) EPS insulation board, or DOW Styrofoam Stuccomate brand XPS insulation boards recognized in ESR-2142 and described in Section 3.2.3.2, must then be attached using galvanized staples or roofing nails. The insulation board must be followed by lath, as described in Section 3.2.4, fastened through the insulation boards to the studs and perimeter framing with 0.125-inch-diameter (3.18 mm) nails having minimum head diameters of 0.355 inch (9.02 mm), or No. 16-gage corrosion resistant staples having 15/16-inch (23.8 mm) crowns. The fasteners must penetrate a minimum of 1 inch (25.4 mm) into wood framing, and are spaced a maximum of 6 inches (152 mm) on center. The Diamond Wall coating must then be applied to the lath in accordance with Section 4.1, at a minimum thickness of 3/8 inch (9.5 mm). 4.4.5.3 Axial Design (2-by-4 Wood Construction): The allowable axial loading for this system is limited as described in Section 4.4.3.3. 4.4.5.4 Axial Design (2-by-6 Wood Construction): The allowable axial loading for this system is limited as described in Section 4.4.3.4. 4.5 Noncombustible Construction: For the purposes of this report, noncombustible construction includes Types I, II, III and IV construction under the IBC. Under the 2018, 2015 and 2012 IBC, for exterior walls on buildings of Type I, II, III, or IV construction, recognition is limited to walls no greater than 40 feet (21.19 m) in height above grade as indicated in 2018 IBC Section 1402.5 (2015 and 2012 IBC Section 1403.5). The Diamond wall stucco system when installed per Section 4.5.2 of this report, complies with Exception 2 of the 2018 IBC Section 1402.5 (2015 IBC Section 1403.5) provided an approved water -resistive barrier is installed as indicated therein. 4.5.1 With Foam Plastic: The stucco system with EPS foam plastic must be installed as noted in Sections 4.5.1.1 through 4.5.1.6. 4.5.1.1 Interior Finish: One layer of 5/8-inch-thick (15.9 mm), Type X gypsum wallboard, complying with ASTM C36 or ASTM C1396, must be applied vertically to steel framing with all edges blocked. Fasteners are No. 8 by 11/4-inch-long (32 mm) buglehead screws fastened to wallboard joints at 8 inches (203 mm) on center and to intermediate locations at 12 inches (305 mm) on center. All joints must be taped and treated with joint compound in accordance with ASTM C840 or GA216. Intermediate fasteners must be treated with joint compound in accordance with ASTM C840 or GA216. 4.5.1.2 Steel Framing: The steel framing must be minimum 35/8-inch-deep (92 mm), minimum No. 20 gage [0.0359 inch (0.91 mm)] steel studs, spaced a maximum of 16 inches (406 mm) on center. 4.5.1.3 Openings: Wall openings must be framed with minimum 0.125-inch-thick (3.2 mm) aluminum or steel framing. 4.5.1.4 Exterior Finish: One layer of minimum 1/2-inch- thick (12.7 mm), water-resistant core -treated gypsum sheathing, complying with ASTM C79 or ASTM C1396, must be applied horizontally or vertically to the steel framing using No. 8 by 11/4-inch-long (32 mm) buglehead screws spaced 8 inches (203 mm) on center at all framing locations. 4.5.1.5 Fire Stopping at Floor Level: Where studs continue past floor levels, stud cavities at each floor level must be blocked with mineral wool batt insulation designed for fire blocking applications. The mineral wool insulation must be fitted into each stud cavity at the floor. The insulation must have a minimum 4 pcf (64 kg/m3) density, must be 4 inches (102 mm) thick and must be approximately 6 to 8 inches (152 to 203 mm) wide. To fit within a stud cavity, it must be long enough to achieve a friction fit. 4.5.1.6 Stucco System: Where a water -resistive barrier is required, the stucco system must include one layer of a water -resistive barrier as described in Section 3.2.9.1, having a flame -spread index of 25 or less and a smoke - developed index of 450 or less. The water -resistive barrier must be installed over the sheathing in accordance with 2018 IBC Section 1403.2 (2015, 2012 and 2009 IBC Section 1404.2) EPS insulation board with a nominal 1.5 pcf (24 kg/m3) density must be installed at a 1-inch (25 mm) thickness horizontally in running bond to the sheathing. The lath, insulation board, and water -resistive barrier must be positively fastened to the steel framing using No. 8 by 21/2-inch-long (63.5 mm), waferhead, self - drilling screws spaced 8 inches (203 mm) on center to all framing members. The Diamond Wall stucco system must be applied at a 3/8-inch (9.5 mm) minimum thickness in accordance with Section 4.0. 4.5.2 Without Foam Plastic: The Diamond Wall stucco system must be applied over gypsum sheathing and steel studs in accordance with Section 4.3.3 without the foam plastic. ESR-1194 1 Most Widely Accepted and Trusted Page 7 of 12 4.6 Miscellaneous: 4.6.1 Inspection Requirements: Building department inspection is required of lath installation prior to application of the coating, as required by the applicable code. The Diamond Wall PM System requires special inspections, in accordance with IBC Section 1704, for field-batching and mixing of components. As an alternative, when approved by the code official, continuous field inspection of all batching and mixing operations, by an authorized inspector, trained and approved by Omega Products International, Inc., may be used. The authorized inspector must be independent of the plastering contractor. A declaration, such as that shown in Figure 4, must be completed and signed in duplicate, for presentation to the building owner and the code official with the plastering contractor's installation card. 4.6.2 Control Joints: Control joints must be installed as specified by the architect or designer. 4.6.3 Curing: Moist curing must be provided for a minimum of 24 hours after coating applications. The length of time and most effective procedure for moist curing will depend on climatic and job conditions. 4.6.4 Soffits: The system may be applied to soffits, provided the coating is applied over metal lath complying with Section 3.2.4.2 in lieu of wire fabric lath. Metal lath fastening must comply with ASTM C926 or C1063 (IBC), or 2018 and 2015 IRC Section R703.7.1, or 2012 and 2009 IRC Section R703.6.1, as applicable except the fastener length must be increased by the thickness of any substrate. 4.6.5 Sills: The system may be applied to sills at locations such as windows and other similar areas. Sills with depths of 6 inches (152 mm) or less may have the coating and lath applied to any substrate permitted in this report, provided the coating, lath, water -resistive barrier and substrate are installed in accordance with the appropriate sections of this report. Sills with depths exceeding 6 inches (152 mm) must have substrates of solid wood or plywood. The substrate must be fastened in accordance with 2018 and 2015 IBC Table 2304.10.1, 2012 and 2009 IBC Table 2304.9.1, or IRC Table R602.3(1), as applicable and a double layer of a complying water -resistive barrier must be applied over the substrate. The coating, lath, and optional insulation board are applied in accordance with Section 4.2. 5.0 CONDITIONS OF USE The Omega Diamond Wall and Diamond Wall PM Insulating Exterior Stucco Systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.4 The system is recognized as a one -hour fire - resistance -rated assembly when installation complies with Section 4.4 of this report. 5.5 The interior of the building must be separated from the foam plastic insulation board with a thermal barrier complying with the applicable code, such as 1/2-inch (12.7 mm) regular gypsum wallboard mechanically attached in accordance with the code. 5.6 A completed installation card, such as that shown in Figure 3, must be left at the jobsite for the owner, and a copy must be filed with the building department. 5.7 For the Diamond Wall PM System, inspections are required in accordance with Section 4.6.1. A declaration, such as that shown in Figure 4, must be left with the building owner, and a copy must be filed with the code official. 5.8 The allowable wind load on the systems are as follows: 5.8.1 For wood studs having a minimum specific gravity of 0.50 (Douglas fir —larch) or steel studs at a maximum of 24 inches (610 mm) on center, allowable wind load is 35 psf (1676 Pa) positive or negative when installation is over open framing in accordance with Section 4.2.1. For installations over wood structural panel sheathing using alternate fastener spacing and various wood species, see Tables 1 and 2. 5.8.2 For wood studs having a minimum specific gravity of 0.42 (spruce -pine -fir) at a maximum spacing of 24 inches (610 mm) on center, allowable wind load is 29 psf (1388 Pa) positive or negative when installation is over open framing in accordance with Section 4.2.1. Support framing must be adequate to resist the required wind load, with a maximum allowable deflection of /240 of the span. 5.9 Foam plastic insulation boards on exterior walls of wood construction must be located at least 6 inches (152 mm) from the ground in areas where hazard of termite damage is very heavy in accordance with 2012 IBC Section 2306.9, 2018, 2015 and 2009 IBC Section 2603.8, IRC Section R318.4, as applicable. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Cementitious Exterior Wall Coatings (AC11), dated January 2013 (editorially revised May 2018). 6.2 Data in accordance with ASTM E119. 6.3 Data in accordance with NFPA 285. 7.0 IDENTIFICATION 5.1 The materials and methods of installation must comply with this report and the manufacturer's 7.1 published instructions. In the event of conflict between the manufacturer's published installation instructions and this report, this report governs. 5.2 Installation must be by contractors approved by Omega Products International, Inc. 5.3 The system is recognized for use in noncombustible construction when installation is in accordance with Section 4.5. Under the 2018, 2015 and 2012 IBC, for exterior walls on buildings of Type I, II, III, or IV construction, recognition is limited to walls no greater than 40 feet (21.19 m) in height above grade as indicated in 2018, 2015 and 2012 IBC Section 1403.5, except as permitted under Exception 2 of the 2018 IBC Section 1402.5 (2015 IBC Section 1403.5). The Diamond Wall stucco is delivered to the jobsite in labeled, 80-pound (36 kg), water -resistive bags bearing labels with the following information: a. Name and address of manufacturer (Omega Products International, Inc.) and the evaluation report number (ESR-1194). b. Identification of components. C. Weight of packaged mix. d. Storage instructions. e. Maximum amount of water and other components that may be added, and conditions that must be considered in determining actual amounts added. f. Curing instructions. ESR-1194 1 Most Widely Accepted and Trusted Page 8 of 12 7.2 Foam plastic insulation boards must be identified in accordance with their respective ICC-ES evaluation reports. Additionally, the board density must be noted. When applied to walls required to be of noncombustible construction, along one edge of each board, and on both faces of one board in each package, the foam plastic must be labeled with the name "Omega Diamond Wall" and the evaluation report number (ESR-1194); and the information required by the insulation board's ICC-ES evaluation report. 7.3 Fome-Cor° Board must be identified in accordance with evaluation report ESR-1614. 7.4 DOW Styrofoam Stuccomate brand XPS insulation boards must be identified in accordance with ESR-2142. 7.5 The report holder's contact information is the following: OMEGA PRODUCTS INTERNATIONAL, INC. 1681 CALIFORNIA AVENUE CORONA, CALIFORNIA 92881 (800) 600-6634 www.omeaa-products.com info(ftmeaa-products.com TABLE 1—FASTENER SPACINGS FOR LATH ATTACHMENT TO WOOD STUDS WITH WOOD STRUCTURAL PANEL SHEATHING AND NOMINAL'/2-INCH-THICK FOAM PLASTIC1,2 (inches) WOOD SPECIES SPECIFIC GRAVITY STAPLE GAGE 163 15 14 13 12 Douglas fir —larch Douglas fir —South 0.50 0.46 6 6 6 6 6 6 6 6 6 6 Western hemlock Western hemlock —South 0.47 0.47 6 6 6 6 6 6 6 6 6 6 Hem -fir —South 0.46 6 6 6 6 6 Hem -fir 0.43 5 6 6 6 6 Spruce -pine -fir 0.42 4 5 6 6 6 Western woods 0.36 4 4 4 5 5 For SI: 1 inch = 25.4 mm. 'Wood structural panel sheathing must be fastened in accordance with the applicable code. 2For lath attachment, fasteners must have sufficient length to penetrate a minimum of 1 inch into the framing. 'As an alternate to the 16 gage staple, 11 gage roofing nails can be used at the tabulated spacing. TABLE 2—FASTENER SPACINGS FOR LATH ATTACHMENT TO WOOD STRUCTURAL PANEL SHEATHING AND WOOD STUDS WITH 1-INCH-THICK FOAM PLASTIC1,2 (inches) STAPLE GAGE WOOD SPECIES SPECIFIC GRAVITY 163 15 14 13 12 Western hemlock 0.47 4 4 4 5 6 Western hemlock —South 0.47 4 4 5 6 6 Hem -fir —South 0.46 4 4 4 5 6 Hem -fir 0.43 4 4 4 5 6 Spruce -pine -fir 0.42 4 4 5 5 6 Western woods 1 0.36 1 3 1 3 1 3 3 1 4 For SI: 1 inch = 25.4 mm. 'Wood structural panel sheathing must be fastened in accordance with the applicable code, except that the intermediate stud fastener spacing must be 6 inches on center. 2For lath attachment, fasteners must have sufficient length to penetrate a minimum of 1 inch into sheathing and framing. 'As an alternate to the 16-gage staple, 11-gage roofing nails can be used at the tabulated spacing. ESR-1194 1 Most Widely Accepted and Trusted Page 9 of 12 e A A Er WX SECTION A -A NOTE 1. GROOVE SPACING MAY BE DECREASED. GROOVE DEPTH AID WIOTH MAY BE ROUSED- FIGURE 1A-TONGUE AND GROOVE FOAM BOARD TYPICAL TERMINATION AT FOUNDATION FIGURE 1B—GROOVED FOAM BOARD IYPICAL IEHMINATION AT DECK OMEGA FRISH OMEGA OIAMOID WALL BASE COAT (I'll, w APPADVED METAL LATH APPROVED P=tATKIN BONG APPROVED WEATHER RESISTIVE BARRIER ITCLLATION WHE1E OQcIJ ", APPROVED WEEP ACCESSORY GH=11 kuDrE.'L—'. 0 NDTF1 A•MN AROVE GRy7E. tMIN ABOVE PAN81 SWXFMWRTISCAPE, OR AS SPECW BYLOM DON FIGURE 2—TYPICAL DETAILS ONEGAFNISH OMEGA ➢IALEND WALL 945E COAT (3B'w PPNIOM WEEP ADDESDDRY FLASH14G W 3 EKTEAU BEMD EPS Mt&ATHON O• LIN WOOD DECK BOAROG Y MOD SUPPORT STRIP FLASHNG HD 2 EKTEW BEHIC FLAGIANG ND 3 1 NN WOOD OECK FR M6 F"AG NO. 1, EKTEAD BEHIND RABNNG W. 2 T MN. APPROVED U4LANF AFFROYED METAL LATH AWROVED INSULATION Rf1AF'; APPROVED WEATHER RE%TryE BARRIER ESR-1194 1 Most Widely Accepted and Trusted Page 10 of 12 TYPICAL PARAPET FLAGHING MEMBRANE �YEGA :NOSH DMEGADIAMOND'WALL BASE .CAT 9E' AtlN APPROVED METAL AM APPROVED INOOLATION BOARD APPROVED WEATHER A E`LXiTNE BARRIER APPROVED CAv1NR ACCESSORY ROORK MATERIAL ROLLED UP BEHIND FLASHIIKG =AA" APPROVED SNEAMNG TYPICAL TERMINATION AT WINDOW FRMING APPROVED WEATHER RESISTNE BARRIER APPROVED NSUL,ATRCN BOARD OMEGA DIAMD!ID WALL BASE COAT V MN OMEGA FNKVH APPROVED METAL LATH AROO'A TYPICAL FLASHING AROUND A WADOW AWROYED FLArNNB LNOER WEATHER RAPS" WINDOW SHWA WRAP WEATHER BARRIER ANNOYED FLADHNB OVT31 WEATHER BARRIER ATTACHMENT OF FOAM PLANT-ONS AGA FNC DUU.ONE 0OAT Y,' LAM LAT10N BC TiEA BAR LATM AM PLANT FASTENER ..NELY A' I PLANT{ I EMBEDO IwED BA DYFRLAR OND WALI TYPICAL CORNER DETAILS BULLNXE CORNER AD OMEGARNSH OMEGA DIAMOND WALL WE COAT 3V( MIN APPROVED 4ETAL LATH APPRC 41) NGUATION POARD APPR74D'MEAT4 RESISTIVE BARRIS FRAMING f CORNS AD FIGURE 2—TYPICAL DETAILS (Continued) ESR-1194 1 Most Widely Accepted and Trusted Page 11 of 12 INSTALLATION CARD Diamond Wall One Coat System Omega Products International, Inc. Project Address Date Completed: Plastering Contractor Name: Address: Telephone No.( ) Approved contractor number as issued by Omega Products Intl'I, Inc. ICC Evaluation Service, Inc. Report ESR-1194 This is to certify that the exterior coating system on the building exterior at the above address has been installed in accordance with the evaluation report and the manufacturer's instructions. Signature of authorized representative of plastering contractor Date This installation card must be presented to the building inspector after completion of work and before final inspection. Project Address: FIGURE 3 DECLARATION Diamond Wall PM Omega Products International, Inc. 1681 California Drive Corona, CA 92881 Phone: (951) 737-7447 Fax: (951) 737-8636 Date: The field batching and mixing of all components of the exterior wall coating at the address noted above have been continuously inspected. The field batching and mixing have been found to comply with current evaluation report ESR-1194 and approved plans. Authorized Inspector's Signature: Authorized Inspector's Name (print): Employer's Name: Employer's Address: Telephone Number: Fax Number: *This is to certify that the above noted inspector, approved by Omega Products International, Inc., was authorized to inspect the project so noted and was trained to properly discharge his duties. Omega Officer Signature: Signer's Name (print:) Date: *Signature required only if inspector is not an employee of Omega Products International, Inc. FIGURE 4 ICC-ES Evaluation Report ESR-1194 CBC and CRC Supplement Reissued November 2020 This report is subject to renewal November 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 09 00 00—FINISHES Section: 09 24 00—Portland Cement Plastering REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC. EVALUATION SUBJECT: OMEGA DIAMOND WALL AND DIAMOND WALL PM INSULANTING EXTERIOR STUCCO SYSTEMS 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Omega Diamond Wall and Diamond PM Insulating Exterior Stucco Systems, described in ICC-ES evaluation report ESR-1194, have also been evaluated for compliance with the codes noted below. Applicable code edition(s): ■ 2019 and 2016 California Building Code® (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. ■ 2019 and 2016 California Residential Code® (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Omega Diamond Wall and Diamond PM Insulating Exterior Stucco Systems, described in Sections 2.0 through 7.0 of the evaluation report ESR-1194, comply with CBC Chapter 25, provided the design and installation are in accordance with the 2018 and 2015 International Building Code' (IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapters 25 and 26, as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Omega Diamond Wall and Diamond PM Insulating Exterior Stucco Systems, described in Sections 2.0 through 7.0 of the evaluation report ESR-1194, complies with CRC Chapter 7, provided the design and installation are in accordance with the 2018 and 2015 International Residential Code° (IRC) provisions noted in the evaluation report. This supplement expires concurrently with the evaluation report, reissued November 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as R to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2020 ICC Evaluation Service, LLC. All rights reserved. Page 12 of 12 rw INTERWEST Remit to: Interwest Consulting Group P.O. Box 18330 Boulder, CO 80308 Direct questions to: Ashley Avery aavery@interwestgrp.com Invoice No.: Invoice Date: Jurisdiction No.: Interwest Job No 69421 5/28/2021 BCPR2021-0011 LAQ21-0037 Residential - BCPR2021-0011- Coral Mtn PGA West Model J 80750 Avenue 58 Professional Services for the Period January 1 through May 28, 2021 Bill to: City of La Quinta Attention Danny Castro, Design & Development Director 78495 Calle Tampico La Quinta, CA 92253 Project Total Invoice Total $312.50 Person Title Week End Hours Rate Total Bryan Montes Plan Check Engineer 1 5/30/2021 1 2.5 $125.00 $312.50 $312.50 rw INTERWEST Remit to: Interwest Consulting Group P.O. Box 18330 Boulder, CO 80308 Direct questions to: Ashley Avery aavery@interwestgrp.com Invoice No.: Invoice Date: Jurisdiction No.: Interwest Job No.: 70768 7/21/2021 BCPR2021-0011 LAQ21-0037 Residential - BCPR2021-0011 - Coral Mtn PGA West Model J 80750 Avenue 58 Professional Services for the Period July 1 through July 21. 2021 Bill to: City of La Quinta Attention Danny Castro, Design & Development Director 78495 Calle Tampico La Quinta, CA 92253 Project Total Invoice Total 1 $125.00 Person Title Week End Hours Rate Total