Cantera at Coral Mountain TR 31249 BCPR2023-1000 - Title 24 - Revision 1CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 1 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
GENERAL INFORMATION
01 Project Name Plan 1 V122 (2179)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2022
06 Zip code 92210 07 Software Version EnergyPro 9.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2179 19 Glazing Percentage (%)14.60%
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
BCPR2023-1000 - CANTERA AT CORAL MOUNTAIN
REVISION 1
RELOCATION OF HEAT PUMP WATER HEATERS TO GARAGE
LOCATIONS FOR ALL PLAN TYPES. THIS INCLUDES
MODIFICATIONS TO ELECTRICAL, PLUMBING, AND STRUCTURAL
FRAMING. ADDITIONALLY, CONDITIONED SPACE FOR PLANS 3 AND
4 REDUCED BY 10SF. 2022 CALIFORNIA BUILDING CODES.
04/12/2024
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 2 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 35.2 42.7 23.2
Proposed Design
North Facing 33.6 35.8 21.4 1.6 6.9 1.8
East Facing 33.9 37.2 22.4 1.3 5.5 0.8
South Facing 33.4 34.9 20.9 1.8 7.8 2.3
West Facing 33.9 36.6 21.9 1.3 6.1 1.3
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 5.40 kWdc
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 3 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.39 1.78 0 0 0.39 1.78
Space Cooling 3.66 70.03 3.05 55.17 0.61 14.86
IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09
Water Heating 0.79 8.27 0.68 7.68 0.11 0.59
Self
Utilization/Flexibility
Credit
0 0
North Facing
Efficiency Compliance
Total
5.62 88.17 4.8 74.03 0.82 14.14
Space Heating 0.39 1.78 0.01 0.07 0.38 1.71
Space Cooling 3.66 70.03 3.16 58.08 0.5 11.95
IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09
Water Heating 0.79 8.27 0.66 7.54 0.13 0.73
Self
Utilization/Flexibility
Credit
0 0
East Facing Efficiency
Compliance Total
5.62 88.17 4.9 76.87 0.72 11.3
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 4 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.39 1.78 0.04 0.17 0.35 1.61
Space Cooling 3.66 70.03 2.98 53.11 0.68 16.92
IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09
Water Heating 0.79 8.27 0.66 7.54 0.13 0.73
Self
Utilization/Flexibility
Credit
0 0
South Facing
Efficiency Compliance
Total
5.62 88.17 4.75 72 0.87 16.17
Space Heating 0.39 1.78 0.01 0.03 0.38 1.75
Space Cooling 3.66 70.03 3.14 56.77 0.52 13.26
IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09
Water Heating 0.79 8.27 0.68 7.69 0.11 0.58
Self
Utilization/Flexibility
Credit
0 0
West Facing Efficiency
Compliance Total
5.62 88.17 4.9 75.67 0.72 12.5
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 5 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
ENERGY USE INTENSITY
Standard Design (kBtu/ft
2 - yr )Proposed Design (kBtu/ft
2 - yr )Compliance Margin (kBtu/ft
2 - yr )
Margin Percentage
North Facing
Gross EUI
1 18.02 16.77 1.25 6.94
Net EUI
2 3.57 4 -0.43 -12.04
East Facing
Gross EUI
1 18.02 16.88 1.14 6.33
Net EUI
2 3.57 4.11 -0.54 -15.13
South Facing
Gross EUI
1 18.02 16.38 1.64 9.1
Net EUI
2 3.57 3.61 -0.04 -1.12
West Facing
Gross EUI
1 18.02 17.05 0.97 5.38
Net EUI
2 3.57 4.28 -0.71 -19.89
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 6 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.6 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Indoor air quality, balanced fan
•IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•IAQ Ventilation System: fault indicator display
•Non-standard roof reflectance
•Insulation below roof deck
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified SEER/SEER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
•Recirculation, Demand Control Push Button
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 7 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1 V122 (2179)2179 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Status
Home Conditioned HVAC System1 2179 9.04 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 305 69 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 350 45 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 545 198 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 499.6 30 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 239.9 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 149.1 0 n/a
Roof Home R-0+R-49 BD n/a n/a 2179 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 794 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 239.9 112 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 358.8 17.8 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 208.9 0 90
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 8 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Front Exterior
Wall 2x6
Front 0 1 45 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior
Wall 2x6
Left 90 1 45 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 198 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior
Wall 2x6
Right 270 1 30 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 24 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Left Exterior Wall 17.8 0.7
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 9 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab-on-Grade Home 2179 187 none 0 80%No
Slab-on-Grade 2 __Garage__794 89 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 10 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-36.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-49 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required Required 492.5 1.5
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units
Solar Heating
System
Compact
Distribution HERS Verification
Water Heater
Name (#)
DHW Sys 1
Domestic Hot
Water (DHW)
HERS Verified
Demand
Recirculation
Manual Control
DHW Heater 1 1 n/a None DHW Sys
1-hers-dhw DHW Heater 1 (1)
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 11 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)
NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 50 Rheem RheemPROH50T2RH
310BM __Garage____Garage____Garage__
RECIRCULATION LOOPS
01 02 03 04 05
Water Heating System Name Number of Recirculation Loops Loop Insulation Thickness (in)Recirculation Loop Location Recirculation Pump Power (W)
DHW Sys 1 1 1.5 Conditioned 0
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name
Heating Equipment
Count Cooling Unit Name
Cooling Equipment
Count Fan Name Distribution Name
Required
Thermostat Type
HVAC System1
Heating and
cooling system
other
Heating
Component 1
1 Cooling
Component 1
1 HVAC Fan 1
Air Distribution
System 1
Setback
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 12 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric
Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling
Component 1
Central split AC 1 EER2/SEER2 12.5 15.2 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Not Required Not Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct
Air Distribution
System 1-hers-dist
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 13 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)
Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness - SRE
Includes Fault
Indicator Display?
HERS Verification Status
SFam IAQVentRpt
1-1 123 0.853659 Balanced Yes 75 No Yes
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 14 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-06-21 09:04:19
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Andre Pujic
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2023-06-21 10:01:37
702-365-8080
Jody Young
Beazer Homes- California
310 Commerce, Suite 150
Irvine, CA 92602
2023-06-21 10:07:56
NA
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 1 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
GENERAL INFORMATION
01 Project Name Plan 2 V123 (2333)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2022
06 Zip code 92210 07 Software Version EnergyPro 9.1
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2333 19 Glazing Percentage (%)14.20%
20 ADU Bedroom Count n/a
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 2 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 34.8 42.5 22.9
Proposed Design
North Facing 32.9 35.4 21.6 1.9 7.1 1.3
East Facing 32.9 35.2 21.6 1.9 7.3 1.3
South Facing 32.8 34.8 21.3 2 7.7 1.6
West Facing 32.7 34.7 21.1 2.1 7.8 1.8
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 5.59 kWdc
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 3 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.47 2.13 0 0.01 0.47 2.12
Space Cooling 3.63 69.51 3.03 55.42 0.6 14.09
IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58
Water Heating 0.74 7.85 0.61 6.88 0.13 0.97
Self
Utilization/Flexibility
Credit
0 0
North Facing
Efficiency Compliance
Total
5.59 87.35 4.64 72.75 0.95 14.6
Space Heating 0.47 2.13 0.02 0.07 0.45 2.06
Space Cooling 3.63 69.51 3.02 55.3 0.61 14.21
IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58
Water Heating 0.74 7.85 0.59 6.66 0.15 1.19
Self
Utilization/Flexibility
Credit
0 0
East Facing Efficiency
Compliance Total
5.59 87.35 4.63 72.47 0.96 14.88
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 4 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.47 2.13 0.05 0.26 0.42 1.87
Space Cooling 3.63 69.51 2.99 54.3 0.64 15.21
IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58
Water Heating 0.74 7.85 0.58 6.66 0.16 1.19
Self
Utilization/Flexibility
Credit
0 0
South Facing
Efficiency Compliance
Total
5.59 87.35 4.62 71.66 0.97 15.69
Space Heating 0.47 2.13 0.02 0.08 0.45 2.05
Space Cooling 3.63 69.51 2.99 54.02 0.64 15.49
IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58
Water Heating 0.74 7.85 0.6 6.84 0.14 1.01
Self
Utilization/Flexibility
Credit
0 0
West Facing Efficiency
Compliance Total
5.59 87.35 4.61 71.38 0.98 15.97
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 5 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
ENERGY USE INTENSITY
Standard Design (kBtu/ft
2 - yr )Proposed Design (kBtu/ft
2 - yr )Compliance Margin (kBtu/ft
2 - yr )
Margin Percentage
North Facing
Gross EUI
1 17.43 16.04 1.39 7.97
Net EUI
2 3.45 4.11 -0.66 -19.13
East Facing
Gross EUI
1 17.43 15.85 1.58 9.06
Net EUI
2 3.45 3.92 -0.47 -13.62
South Facing
Gross EUI
1 17.43 15.79 1.64 9.41
Net EUI
2 3.45 3.86 -0.41 -11.88
West Facing
Gross EUI
1 17.43 15.91 1.52 8.72
Net EUI
2 3.45 3.98 -0.53 -15.36
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 6 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.6 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Indoor air quality, balanced fan
•IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•IAQ Ventilation System: fault indicator display
•Non-standard roof reflectance
•Insulation below roof deck
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified SEER/SEER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 7 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2 V123 (2333)2333 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Status
Home Conditioned HVAC System1 2333 9.04 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 0 Front 227.1 54 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 90 Left 510.2 99 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS +R4 180 Back 545 140 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 270 Right 666.1 62 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 317.9 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 158.2 0 n/a
Roof Home R-0+R-49 BD n/a n/a 2333 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 767 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 317.9 168 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 212.7 17.8 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 74.2 0 90
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 8 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Front Exterior
Wall 2x6
Front 0 1 30 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior
Wall 2x6
Left 90 1 99 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 140 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior
Wall 2x6
Right 270 1 62 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 24 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 168 1
Door 4 Left Exterior Wall 17.8 0.7
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 9 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab-on-Grade Home 2333 214 none 0 80%No
Slab-on-Grade 2 __Garage__767 67 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS +R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 10 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-36.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-49 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required Required 527.3 1.5
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units
Solar Heating
System
Compact
Distribution HERS Verification
Water Heater
Name (#)
DHW Sys 1
Domestic Hot
Water (DHW)
Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1)
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 11 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)
NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 50 Rheem RheemPROH50T2RH
310BM __Garage____Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name
Heating Equipment
Count Cooling Unit Name
Cooling Equipment
Count Fan Name Distribution Name
Required
Thermostat Type
HVAC System1
Heating and
cooling system
other
Heating
Component 1
1 Cooling
Component 1
1 HVAC Fan 1
Air Distribution
System 1
Setback
HVAC - HEATING UNIT TYPES
01 02 03 04
Name System Type Number of Units Heating Efficiency
Heating Component 1 Central gas furnace 1 AFUE-96
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 12 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric
Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling
Component 1
Central split AC 1 EER2/SEER2 12.5 15.9 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Not Required Not Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 13 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)
Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness - SRE
Includes Fault
Indicator Display?
HERS Verification Status
SFam IAQVentRpt
1-1 123 0.853659 Balanced Yes 75 No Yes
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 14 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-07-05 08:21:02
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Andre Pujic
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2023-07-05 09:03:45
702-365-8080
Jody Young
Beazer Homes- California
310 Commerce, Suite 150
Irvine, CA 92602
2023-07-05 09:37:39
NA
714-285-2900 7021
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 1 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
GENERAL INFORMATION
01 Project Name Plan 3 S812 (2660)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2022
06 Zip code 92210 07 Software Version EnergyPro 9.2
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2660 19 Glazing Percentage (%)14.77%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 2 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 34.2 42.6 22.5
Proposed Design
North Facing 32.1 34.9 21.3 2.1 7.7 1.2
East Facing 32 34.7 21.2 2.2 7.9 1.3
South Facing 32.2 34.7 21.3 2 7.9 1.2
West Facing 31.9 33.9 20.6 2.3 8.7 1.9
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 5.89 kWdc
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 3 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.49 2.25 0.03 0.21 0.46 2.04
Space Cooling 3.41 65.94 2.81 51.83 0.6 14.11
IAQ Ventilation 0.71 7.46 0.88 9.16 -0.17 -1.7
Water Heating 0.66 6.96 0.58 6.54 0.08 0.42
Self
Utilization/Flexibility
Credit
0 0
North Facing
Efficiency Compliance
Total
5.27 82.61 4.3 67.74 0.97 14.87
Space Heating 0.49 2.25 0.03 0.22 0.46 2.03
Space Cooling 3.41 65.94 2.78 51.44 0.63 14.5
IAQ Ventilation 0.71 7.46 0.88 9.16 -0.17 -1.7
Water Heating 0.66 6.96 0.57 6.43 0.09 0.53
Self
Utilization/Flexibility
Credit
0 0
East Facing Efficiency
Compliance Total
5.27 82.61 4.26 67.25 1.01 15.36
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 4 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.49 2.25 0.07 0.41 0.42 1.84
Space Cooling 3.41 65.94 2.8 51.49 0.61 14.45
IAQ Ventilation 0.71 7.46 0.88 9.16 -0.17 -1.7
Water Heating 0.66 6.96 0.56 6.29 0.1 0.67
Self
Utilization/Flexibility
Credit
0 0
South Facing
Efficiency Compliance
Total
5.27 82.61 4.31 67.35 0.96 15.26
Space Heating 0.49 2.25 0.05 0.29 0.44 1.96
Space Cooling 3.41 65.94 2.74 49.89 0.67 16.05
IAQ Ventilation 0.71 7.46 0.88 9.16 -0.17 -1.7
Water Heating 0.66 6.96 0.56 6.39 0.1 0.57
Self
Utilization/Flexibility
Credit
0 0
West Facing Efficiency
Compliance Total
5.27 82.61 4.23 65.73 1.04 16.88
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 5 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
ENERGY USE INTENSITY
Standard Design (kBtu/ft
2 - yr )Proposed Design (kBtu/ft
2 - yr )Compliance Margin (kBtu/ft
2 - yr )
Margin Percentage
North Facing
Gross EUI
1 15.99 14.59 1.4 8.76
Net EUI
2 3.08 3.91 -0.83 -26.95
East Facing
Gross EUI
1 15.99 14.39 1.6 10.01
Net EUI
2 3.08 3.7 -0.62 -20.13
South Facing
Gross EUI
1 15.99 14.37 1.62 10.13
Net EUI
2 3.08 3.68 -0.6 -19.48
West Facing
Gross EUI
1 15.99 14.31 1.68 10.51
Net EUI
2 3.08 3.62 -0.54 -17.53
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 6 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.7 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Indoor air quality, balanced fan
•IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•IAQ Ventilation System: fault indicator display
•Non-standard roof reflectance
•Insulation below roof deck
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified SEER/SEER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
•Recirculation, Demand Control Push Button
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 7 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3 S812 (2660)2660 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Status
Home Conditioned HVAC System1 2660 9.04 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 174.8 70 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 726.6 143 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 481.4 135 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 537.1 65 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 318 17.8 n/a
South Interior Surface
2x Home>>__Garage__Garage R-15 Wall n/a n/a 12.1 0 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 184.7 0 n/a
Roof Home R-0+R-49 BD n/a n/a 2660 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 571 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 306.6 145 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 90.8 0 90
Right Exterior Wall __Garage__R-0 Wall 270 Right 275.5 73.8 90
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 8 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Front Exterior
Wall 2x6
Front 0 1 50 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior
Wall 2x6
Left 90 1 143 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 135 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior
Wall 2x6
Right 270 1 65 0.28 NFRC 0.22 NFRC Bug Screen
Window 5 Window Front Exterior
Wall Front 0 1 33 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 20 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Right Exterior Wall 73.8 0.7
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 9 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab-on-Grade Home 2660 211 none 0 80%No
Slab-on-Grade 2 __Garage__571 74 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086
Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 10 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-36.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-49 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required Required 601.2 1.5
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units
Solar Heating
System
Compact
Distribution HERS Verification
Water Heater
Name (#)
DHW Sys 1
Domestic Hot
Water (DHW)
HERS Verified
Demand
Recirculation
Manual Control
DHW Heater 1 1 n/a None DHW Sys
1-hers-dhw DHW Heater 1 (1)
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 11 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)
NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 50 Rheem
PROH50 T2
RH310BM (50 gal,
JA13l)
TankZone __Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name
Heating Equipment
Count Cooling Unit Name
Cooling Equipment
Count Fan Name Distribution Name
Required
Thermostat Type
HVAC System1
Heating and
cooling system
other
Heating
Component 1
1 Cooling
Component 1
1 HVAC Fan 1
Air Distribution
System 1
Setback
HVAC - HEATING UNIT TYPES
01 02 03 04 05
Name System Type Number of Units Heating Efficiency Heating Unit Brand
Heating Component 1 Central gas furnace 1 AFUE - 96 n/a
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 12 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric
Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling
Component 1
Central split AC 1 EER2/SEER2 12.5 15.9 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 13 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)
Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness -
SRE/ASRE
Includes Fault
Indicator Display?
HERS Verification Status
SFam IAQVentRpt
1-1 123 0.853659 Balanced Yes 69 / 75 Yes Yes
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 3 S812 (2660)Calculation Date/Time:2024-03-11T15:47:49-07:00 (Page 14 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2660).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 15:49:01
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Andre Pujic
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2024-03-11 16:20:01
R19-22-30148
702-365-8080
Marco Hurtado
Beazer Homes- California
310 Commerce, Suite 150
Riverside, CA, CA 92602
2024-03-12 09:09:26
NA
714-672-7167
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
223-P010073370C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 1 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
GENERAL INFORMATION
01 Project Name Plan 4 V067 (2996)
02 Run Title Title 24 Analysis
03 Project Location CANTERA
04 City LA QUINTA 05 Standards Version 2022
06 Zip code 92210 07 Software Version EnergyPro 9.2
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 4
14 Addition Cond. Floor Area (ft
2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft
2)n/a 17 Fenestration Average U-factor 0.28
18 Total Cond. Floor Area (ft
2)2996 19 Glazing Percentage (%)11.42%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 2 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 33.8 43 22.3
Proposed Design
North Facing 30.6 33.3 19 3.2 9.7 3.3
East Facing 30.8 33.9 19.4 3 9.1 2.9
South Facing 30.5 32.9 18.8 3.3 10.1 3.5
West Facing 30.8 33.7 19.3 3 9.3 3
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 6.00 kWdc
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 3 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.44 2.08 0.02 0.18 0.42 1.9
Space Cooling 3.18 59.98 2.46 43.97 0.72 16.01
IAQ Ventilation 0.65 6.77 0.78 8.13 -0.13 -1.36
Water Heating 0.58 6.15 0.51 5.76 0.07 0.39
Self
Utilization/Flexibility
Credit
0 0
North Facing
Efficiency Compliance
Total
4.85 74.98 3.77 58.04 1.08 16.94
Space Heating 0.44 2.08 0.05 0.28 0.39 1.8
Space Cooling 3.18 59.98 2.5 45.02 0.68 14.96
IAQ Ventilation 0.65 6.77 0.78 8.13 -0.13 -1.36
Water Heating 0.58 6.15 0.49 5.61 0.09 0.54
Self
Utilization/Flexibility
Credit
0 0
East Facing Efficiency
Compliance Total
4.85 74.98 3.82 59.04 1.03 15.94
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 4 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
ENERGY USE SUMMARY
Energy Use
Standard Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft
2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft
2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.44 2.08 0.04 0.24 0.4 1.84
Space Cooling 3.18 59.98 2.44 43.3 0.74 16.68
IAQ Ventilation 0.65 6.77 0.78 8.13 -0.13 -1.36
Water Heating 0.58 6.15 0.49 5.64 0.09 0.51
Self
Utilization/Flexibility
Credit
0 0
South Facing
Efficiency Compliance
Total
4.85 74.98 3.75 57.31 1.1 17.67
Space Heating 0.44 2.08 0.03 0.21 0.41 1.87
Space Cooling 3.18 59.98 2.49 44.73 0.69 15.25
IAQ Ventilation 0.65 6.77 0.78 8.13 -0.13 -1.36
Water Heating 0.58 6.15 0.51 5.78 0.07 0.37
Self
Utilization/Flexibility
Credit
0 0
West Facing Efficiency
Compliance Total
4.85 74.98 3.81 58.85 1.04 16.13
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 5 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
ENERGY USE INTENSITY
Standard Design (kBtu/ft
2 - yr )Proposed Design (kBtu/ft
2 - yr )Compliance Margin (kBtu/ft
2 - yr )
Margin Percentage
North Facing
Gross EUI
1 14.42 12.69 1.73 12
Net EUI
2 2.74 2.59 0.15 5.47
East Facing
Gross EUI
1 14.42 12.78 1.64 11.37
Net EUI
2 2.74 2.68 0.06 2.19
South Facing
Gross EUI
1 14.42 12.62 1.8 12.48
Net EUI
2 2.74 2.52 0.22 8.03
West Facing
Gross EUI
1 14.42 12.85 1.57 10.89
Net EUI
2 2.74 2.75 -0.01 -0.36
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 6 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
5 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Indoor air quality, balanced fan
•IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE
•IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual
•IAQ Ventilation System: fault indicator display
•Non-standard roof reflectance
•Insulation below roof deck
•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Building air leakage/reduced infiltration
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified SEER/SEER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Duct leakage testing
•Low-leakage Air Handling Unit
•Recirculation, Demand Control Push Button
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 7 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft
2)Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 4 V067 (2996)2996 1 4 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft
2)Avg. Ceiling Height Water Heating System 1 Status
Home Conditioned HVAC System1 2996 9.04 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft
2)Window and Door
Area (ft2)
Tilt (deg)
Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 0 Front 312.5 100 90
Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 90 Left 487.4 48 90
Rear Wall 2x6 Home R-21 Wall w/1 EPS R4 180 Back 499.6 144 90
Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 270 Right 663.1 70 90
Front Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 187.7 17.8 n/a
Left Interior Surface
2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 354.2 0 n/a
Right Interior Surface
2x Home>>__Garage__Garage R-21 Wall n/a n/a 172.6 0 n/a
Roof Home R-0+R-49 BD n/a n/a 2996 n/a n/a
Roof 2 __Garage__R-0 Roof Attic n/a n/a 620 n/a n/a
Front Exterior Wall __Garage__R-0 Wall 0 Front 187.7 112 90
Left Exterior Wall __Garage__R-0 Wall 90 Left 186.2 16.7 90
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 8 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No
Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Window Window Front Exterior
Wall 2x6
Front 0 1 80 0.28 NFRC 0.22 NFRC Bug Screen
Window 2 Window Left Exterior
Wall 2x6
Left 90 1 48 0.28 NFRC 0.22 NFRC Bug Screen
Window 3 Window Rear Wall 2x6 Back 180 1 144 0.28 NFRC 0.22 NFRC Bug Screen
Window 4 Window Right Exterior
Wall 2x6
Right 270 1 70 0.28 NFRC 0.22 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft
2)U-factor
Door Front Exterior Wall 2x6 20 0.142857
Door 2 Front Interior Surface 2x 17.8 0.285714
Door 3 Front Exterior Wall 112 1
Door 4 Left Exterior Wall 16.7 0.7
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 9 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft
2)Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction Heated
Slab-on-Grade Home 2996 216 none 0 80%No
Slab-on-Grade 2 __Garage__620 41 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall w/1 EPS R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Sheathing / Insulation: R-4 Sheathing
Exterior Finish: Synthetic Stucco
Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 10 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
Attic RoofHome Attic Roofs
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-36.0 insul.
R-0 Roof Attic
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-0+R-49 BD
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required Required 677.1 1.5
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units
Solar Heating
System
Compact
Distribution HERS Verification
Water Heater
Name (#)
DHW Sys 1
Domestic Hot
Water (DHW)
HERS Verified
Demand
Recirculation
Manual Control
DHW Heater 1 1 n/a None DHW Sys
1-hers-dhw DHW Heater 1 (1)
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 11 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
WATER HEATERS - NEEA HEAT PUMP
01 02 03 04 05 06 07 08
Name # of Units Tank Vol. (gal)
NEEA Heat Pump
Brand
NEEA Heat Pump
Model Tank Location Duct Inlet Air Source Duct Outlet Air Source
DHW Heater 1 1 50 Rheem
PROH50 T2
RH310BM (50 gal,
JA13l)
TankZone __Garage____Garage__
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution
Compact Distribution
Type Recirculation Control
Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name
Heating Equipment
Count Cooling Unit Name
Cooling Equipment
Count Fan Name Distribution Name
Required
Thermostat Type
HVAC System1
Heating and
cooling system
other
Heating
Component 1
1 Cooling
Component 1
1 HVAC Fan 1
Air Distribution
System 1
Setback
HVAC - HEATING UNIT TYPES
01 02 03 04 05
Name System Type Number of Units Heating Efficiency Heating Unit Brand
Heating Component 1 Central gas furnace 1 AFUE - 96.1 n/a
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 12 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
HVAC - COOLING UNIT TYPES
01 02 03 04 05 06 07 08 09
Name System Type Number of Units Efficiency Metric
Efficiency
EER/EER2/CEER
Efficiency
SEER/SEER2 Zonally Controlled
Mulit-speed
Compressor HERS Verification
Cooling
Component 1
Central split AC 1 EER2/SEER2 13 16.7 Zonally Controlled Single Speed
Cooling
Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge
Cooling Component
1-hers-cool Required 275 Required Required Required
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct
Air Distribution
System 1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts
Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist
Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 13 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)
Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness -
SRE/ASRE
Includes Fault
Indicator Display?
HERS Verification Status
SFam IAQVentRpt
1-1 125 0.84 Balanced Yes 69 / 75 Yes Yes
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E
Project Name:Plan 4 V067 (2996)Calculation Date/Time:2024-03-11T15:59:45-07:00 (Page 14 of 14)
Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (2296).ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2024-03-11 16:01:10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Andre Pujic
Energy Inspectors
2570 South Miller Lane
Las Vegas, NV 89117
2024-03-11 16:21:31
R19-22-30148
702-365-8080
Marco Hurtado
Beazer Homes- California
310 Commerce, Suite 150
Riverside, CA, CA 92602
2024-03-12 09:09:26
NA
714-672-7167
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
223-P010073373C-000000000-0000 2024-03-12 09:09:26 CalCERTS inc.