Loading...
Cantera at Coral Mountain TR 31249 BCPR2023-1000 - Title 24CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 1 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 GENERAL INFORMATION 01 Project Name Plan 1 V122 (2179) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2022 06 Zip code 92210 07 Software Version EnergyPro 9.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)2179 19 Glazing Percentage (%)14.60% 20 ADU Bedroom Count n/a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. BCPR2023-1000 - CANTERA @ CORAL MOUNTAIN CANTERA BY BEAZER HOMES / CODE UPDATE FOR TRACT CONSTRUCTION MASTER PLANS FOR DWELLINGS (SFD x 4) - PLANS 1, 2, 3, AND 4, FOR THE 2022 CODE CYCLE. PLAN 1: 2,179SF PLAN 2: 2,333SF PLAN 3: 2,670SF PLAN 4: 3,006SF 01/30/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 2 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 35.2 42.7 23.2 Proposed Design North Facing 33.6 35.8 21.4 1.6 6.9 1.8 East Facing 33.9 37.2 22.4 1.3 5.5 0.8 South Facing 33.4 34.9 20.9 1.8 7.8 2.3 West Facing 33.9 36.6 21.9 1.3 6.1 1.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 5.40 kWdc 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 3 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.39 1.78 0 0 0.39 1.78 Space Cooling 3.66 70.03 3.05 55.17 0.61 14.86 IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09 Water Heating 0.79 8.27 0.68 7.68 0.11 0.59 Self Utilization/Flexibility Credit 0 0 North Facing Efficiency Compliance Total 5.62 88.17 4.8 74.03 0.82 14.14 Space Heating 0.39 1.78 0.01 0.07 0.38 1.71 Space Cooling 3.66 70.03 3.16 58.08 0.5 11.95 IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09 Water Heating 0.79 8.27 0.66 7.54 0.13 0.73 Self Utilization/Flexibility Credit 0 0 East Facing Efficiency Compliance Total 5.62 88.17 4.9 76.87 0.72 11.3 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 4 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.39 1.78 0.04 0.17 0.35 1.61 Space Cooling 3.66 70.03 2.98 53.11 0.68 16.92 IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09 Water Heating 0.79 8.27 0.66 7.54 0.13 0.73 Self Utilization/Flexibility Credit 0 0 South Facing Efficiency Compliance Total 5.62 88.17 4.75 72 0.87 16.17 Space Heating 0.39 1.78 0.01 0.03 0.38 1.75 Space Cooling 3.66 70.03 3.14 56.77 0.52 13.26 IAQ Ventilation 0.78 8.09 1.07 11.18 -0.29 -3.09 Water Heating 0.79 8.27 0.68 7.69 0.11 0.58 Self Utilization/Flexibility Credit 0 0 West Facing Efficiency Compliance Total 5.62 88.17 4.9 75.67 0.72 12.5 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 5 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage North Facing Gross EUI 1 18.02 16.77 1.25 6.94 Net EUI 2 3.57 4 -0.43 -12.04 East Facing Gross EUI 1 18.02 16.88 1.14 6.33 Net EUI 2 3.57 4.11 -0.54 -15.13 South Facing Gross EUI 1 18.02 16.38 1.64 9.1 Net EUI 2 3.57 3.61 -0.04 -1.12 West Facing Gross EUI 1 18.02 17.05 0.97 5.38 Net EUI 2 3.57 4.28 -0.71 -19.89 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 6 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 4.6 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV module type: Premium •PV power electronics: Microinverters •Indoor air quality, balanced fan •IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE •IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual •IAQ Ventilation System: fault indicator display •Non-standard roof reflectance •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Duct leakage testing •Low-leakage Air Handling Unit •Recirculation, Demand Control Push Button 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 7 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 1 V122 (2179)2179 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status Home Conditioned HVAC System1 2179 9.04 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 305 69 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 350 45 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 545 198 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 499.6 30 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 239.9 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 149.1 0 n/a Roof Home R-0+R-49 BD n/a n/a 2179 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 794 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 239.9 112 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 358.8 17.8 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 208.9 0 90 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 8 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 45 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 45 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 198 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 30 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 24 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Left Exterior Wall 17.8 0.7 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 9 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2179 187 none 0 80%No Slab-on-Grade 2 __Garage__794 89 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 10 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-36.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-49 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required Required 492.5 1.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Demand Recirculation Manual Control DHW Heater 1 1 n/a None DHW Sys 1-hers-dhw DHW Heater 1 (1) 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 11 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal) NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem RheemPROH50T2RH 310BM __Garage____Garage____Garage__ RECIRCULATION LOOPS 01 02 03 04 05 Water Heating System Name Number of Recirculation Loops Loop Insulation Thickness (in)Recirculation Loop Location Recirculation Pump Power (W) DHW Sys 1 1 1.5 Conditioned 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 Setback 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 12 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER2/SEER2 12.5 15.2 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 13 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam IAQVentRpt 1-1 123 0.853659 Balanced Yes 75 No Yes 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 1 V122 (2179)Calculation Date/Time:2023-06-21T09:03:12-07:00 (Page 14 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 1 V122 (2179).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-06-21   09:04:19 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Andre Pujic Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2023-06-21 10:01:37 702-365-8080 Jody Young Beazer Homes- California 310 Commerce, Suite 150 Irvine, CA 92602 2023-06-21 10:07:56 NA 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010073318A-000000000-0000 2023-06-21 10:07:56 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 1 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 GENERAL INFORMATION 01 Project Name Plan 2 V123 (2333) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2022 06 Zip code 92210 07 Software Version EnergyPro 9.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)2333 19 Glazing Percentage (%)14.20% 20 ADU Bedroom Count n/a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 2 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 34.8 42.5 22.9 Proposed Design North Facing 32.9 35.4 21.6 1.9 7.1 1.3 East Facing 32.9 35.2 21.6 1.9 7.3 1.3 South Facing 32.8 34.8 21.3 2 7.7 1.6 West Facing 32.7 34.7 21.1 2.1 7.8 1.8 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 5.59 kWdc 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 3 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.47 2.13 0 0.01 0.47 2.12 Space Cooling 3.63 69.51 3.03 55.42 0.6 14.09 IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58 Water Heating 0.74 7.85 0.61 6.88 0.13 0.97 Self Utilization/Flexibility Credit 0 0 North Facing Efficiency Compliance Total 5.59 87.35 4.64 72.75 0.95 14.6 Space Heating 0.47 2.13 0.02 0.07 0.45 2.06 Space Cooling 3.63 69.51 3.02 55.3 0.61 14.21 IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58 Water Heating 0.74 7.85 0.59 6.66 0.15 1.19 Self Utilization/Flexibility Credit 0 0 East Facing Efficiency Compliance Total 5.59 87.35 4.63 72.47 0.96 14.88 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 4 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.47 2.13 0.05 0.26 0.42 1.87 Space Cooling 3.63 69.51 2.99 54.3 0.64 15.21 IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58 Water Heating 0.74 7.85 0.58 6.66 0.16 1.19 Self Utilization/Flexibility Credit 0 0 South Facing Efficiency Compliance Total 5.59 87.35 4.62 71.66 0.97 15.69 Space Heating 0.47 2.13 0.02 0.08 0.45 2.05 Space Cooling 3.63 69.51 2.99 54.02 0.64 15.49 IAQ Ventilation 0.75 7.86 1 10.44 -0.25 -2.58 Water Heating 0.74 7.85 0.6 6.84 0.14 1.01 Self Utilization/Flexibility Credit 0 0 West Facing Efficiency Compliance Total 5.59 87.35 4.61 71.38 0.98 15.97 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 5 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage North Facing Gross EUI 1 17.43 16.04 1.39 7.97 Net EUI 2 3.45 4.11 -0.66 -19.13 East Facing Gross EUI 1 17.43 15.85 1.58 9.06 Net EUI 2 3.45 3.92 -0.47 -13.62 South Facing Gross EUI 1 17.43 15.79 1.64 9.41 Net EUI 2 3.45 3.86 -0.41 -11.88 West Facing Gross EUI 1 17.43 15.91 1.52 8.72 Net EUI 2 3.45 3.98 -0.53 -15.36 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 6 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 4.6 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV module type: Premium •PV power electronics: Microinverters •Indoor air quality, balanced fan •IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE •IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual •IAQ Ventilation System: fault indicator display •Non-standard roof reflectance •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Duct leakage testing •Low-leakage Air Handling Unit 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 7 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2 V123 (2333)2333 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status Home Conditioned HVAC System1 2333 9.04 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 0 Front 227.1 54 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 90 Left 510.2 99 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS +R4 180 Back 545 140 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS +R4 270 Right 666.1 62 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 317.9 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 158.2 0 n/a Roof Home R-0+R-49 BD n/a n/a 2333 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 767 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 317.9 168 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 212.7 17.8 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 74.2 0 90 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 8 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 30 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 99 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 140 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 62 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 24 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 168 1 Door 4 Left Exterior Wall 17.8 0.7 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 9 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2333 214 none 0 80%No Slab-on-Grade 2 __Garage__767 67 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS +R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 10 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-36.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-49 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required Required 527.3 1.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 11 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal) NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem RheemPROH50T2RH 310BM __Garage____Garage____Garage__ WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 12 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER2/SEER2 12.5 15.9 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 13 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam IAQVentRpt 1-1 123 0.853659 Balanced Yes 75 No Yes 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 2 V123 (2333)Calculation Date/Time:2023-07-05T08:20:00-07:00 (Page 14 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 2 V123 (2333).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:21:02 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Andre Pujic Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2023-07-05 09:03:45 702-365-8080 Jody Young Beazer Homes- California 310 Commerce, Suite 150 Irvine, CA 92602 2023-07-05 09:37:39 NA 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010073366B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 1 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 GENERAL INFORMATION 01 Project Name Plan 3 S812 (2670) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2022 06 Zip code 92210 07 Software Version EnergyPro 9.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)2670 19 Glazing Percentage (%)14.70% 20 ADU Bedroom Count n/a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 2 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 34.1 42.5 22.4 Proposed Design North Facing 32 34.8 21.2 2.1 7.7 1.2 East Facing 31.8 34.5 21.1 2.3 8 1.3 South Facing 32 34.6 21.2 2.1 7.9 1.2 West Facing 31.7 33.8 20.6 2.4 8.7 1.8 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 5.89 kWdc 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 3 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.45 2.01 0 0.02 0.45 1.99 Space Cooling 3.4 65.77 2.8 51.68 0.6 14.09 IAQ Ventilation 0.71 7.45 0.87 9.12 -0.16 -1.67 Water Heating 0.66 6.94 0.58 6.52 0.08 0.42 Self Utilization/Flexibility Credit 0 0 North Facing Efficiency Compliance Total 5.22 82.17 4.25 67.34 0.97 14.83 Space Heating 0.45 2.01 0 0.02 0.45 1.99 Space Cooling 3.4 65.77 2.77 51.29 0.63 14.48 IAQ Ventilation 0.71 7.45 0.87 9.12 -0.16 -1.67 Water Heating 0.66 6.94 0.57 6.4 0.09 0.54 Self Utilization/Flexibility Credit 0 0 East Facing Efficiency Compliance Total 5.22 82.17 4.21 66.83 1.01 15.34 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 4 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.45 2.01 0.04 0.19 0.41 1.82 Space Cooling 3.4 65.77 2.79 51.34 0.61 14.43 IAQ Ventilation 0.71 7.45 0.87 9.12 -0.16 -1.67 Water Heating 0.66 6.94 0.55 6.26 0.11 0.68 Self Utilization/Flexibility Credit 0 0 South Facing Efficiency Compliance Total 5.22 82.17 4.25 66.91 0.97 15.26 Space Heating 0.45 2.01 0.02 0.11 0.43 1.9 Space Cooling 3.4 65.77 2.73 49.74 0.67 16.03 IAQ Ventilation 0.71 7.45 0.87 9.12 -0.16 -1.67 Water Heating 0.66 6.94 0.56 6.37 0.1 0.57 Self Utilization/Flexibility Credit 0 0 West Facing Efficiency Compliance Total 5.22 82.17 4.18 65.34 1.04 16.83 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 5 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage North Facing Gross EUI 1 15.92 14.52 1.4 8.79 Net EUI 2 3.07 3.88 -0.81 -26.38 East Facing Gross EUI 1 15.92 14.32 1.6 10.05 Net EUI 2 3.07 3.67 -0.6 -19.54 South Facing Gross EUI 1 15.92 14.3 1.62 10.18 Net EUI 2 3.07 3.65 -0.58 -18.89 West Facing Gross EUI 1 15.92 14.24 1.68 10.55 Net EUI 2 3.07 3.59 -0.52 -16.94 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 6 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 4.7 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV module type: Premium •PV power electronics: Microinverters •Indoor air quality, balanced fan •IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE •IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual •IAQ Ventilation System: fault indicator display •Non-standard roof reflectance •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Duct leakage testing •Low-leakage Air Handling Unit •Recirculation, Demand Control Push Button 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 7 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 3 S812 (2670)2670 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status Home Conditioned HVAC System1 2670 9.04 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 0 Front 174.8 70 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 90 Left 726.6 143 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS + R4 180 Back 481.4 135 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS + R4 270 Right 537.1 65 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 318 17.8 n/a South Interior Surface 2x Home>>__Garage__Garage R-15 Wall n/a n/a 12.1 0 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 184.7 0 n/a Roof Home R-0+R-49 BD n/a n/a 2670 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 561 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 306.6 145 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 90.8 0 90 Right Exterior Wall __Garage__R-0 Wall 270 Right 275.5 73.8 90 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 8 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 50 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 143 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 135 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 65 0.28 NFRC 0.22 NFRC Bug Screen Window 5 Window Front Exterior Wall Front 0 1 33 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 20 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Right Exterior Wall 73.8 0.7 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 9 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 2670 211 none 0 80%No Slab-on-Grade 2 __Garage__561 74 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS + R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Garage R-15 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.086 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 10 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-36.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-49 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required Required 603.4 1.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Demand Recirculation Manual Control DHW Heater 1 1 n/a None DHW Sys 1-hers-dhw DHW Heater 1 (1) 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 11 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal) NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem RheemPROH50T2RH 310BM __Garage____Garage____Garage__ RECIRCULATION LOOPS 01 02 03 04 05 Water Heating System Name Number of Recirculation Loops Loop Insulation Thickness (in)Recirculation Loop Location Recirculation Pump Power (W) DHW Sys 1 1 1.5 Conditioned 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 Setback 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 12 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER2/SEER2 12.5 15.9 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 13 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam IAQVentRpt 1-1 123 0.853659 Balanced Yes 75 No Yes 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 3 S812 (2670)Calculation Date/Time:2023-07-05T08:36:47-07:00 (Page 14 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 3 S812 (2670).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:37:52 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Andre Pujic Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2023-07-05 09:04:33 702-365-8080 Jody Young Beazer Homes- California 310 Commerce, Suite 150 Irvine, CA 92602 2023-07-05 09:37:39 NA 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010073370B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 1 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 GENERAL INFORMATION 01 Project Name Plan 4 V067 (3006) 02 Run Title Title 24 Analysis 03 Project Location CANTERA 04 City LA QUINTA 05 Standards Version 2022 06 Zip code 92210 07 Software Version EnergyPro 9.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 4 14 Addition Cond. Floor Area (ft 2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)n/a 17 Fenestration Average U-factor 0.28 18 Total Cond. Floor Area (ft 2)3006 19 Glazing Percentage (%)11.40% 20 ADU Bedroom Count n/a COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 2 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 33.8 42.9 22.3 Proposed Design North Facing 30.5 33.2 18.9 3.3 9.7 3.4 East Facing 30.7 33.7 19.4 3.1 9.2 2.9 South Facing 30.4 32.8 18.7 3.4 10.1 3.6 West Facing 30.7 33.6 19.2 3.1 9.3 3.1 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 5.99 kWdc 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 3 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.41 1.87 0 0.01 0.41 1.86 Space Cooling 3.17 59.83 2.45 43.85 0.72 15.98 IAQ Ventilation 0.65 6.75 0.78 8.1 -0.13 -1.35 Water Heating 0.58 6.14 0.51 5.75 0.07 0.39 Self Utilization/Flexibility Credit 0 0 North Facing Efficiency Compliance Total 4.81 74.59 3.74 57.71 1.07 16.88 Space Heating 0.41 1.87 0.02 0.1 0.39 1.77 Space Cooling 3.17 59.83 2.5 44.9 0.67 14.93 IAQ Ventilation 0.65 6.75 0.78 8.1 -0.13 -1.35 Water Heating 0.58 6.14 0.49 5.59 0.09 0.55 Self Utilization/Flexibility Credit 0 0 East Facing Efficiency Compliance Total 4.81 74.59 3.79 58.69 1.02 15.9 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 4 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft 2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft 2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft 2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.41 1.87 0.02 0.07 0.39 1.8 Space Cooling 3.17 59.83 2.43 43.18 0.74 16.65 IAQ Ventilation 0.65 6.75 0.78 8.1 -0.13 -1.35 Water Heating 0.58 6.14 0.49 5.63 0.09 0.51 Self Utilization/Flexibility Credit 0 0 South Facing Efficiency Compliance Total 4.81 74.59 3.72 56.98 1.09 17.61 Space Heating 0.41 1.87 0.01 0.04 0.4 1.83 Space Cooling 3.17 59.83 2.49 44.61 0.68 15.22 IAQ Ventilation 0.65 6.75 0.78 8.1 -0.13 -1.35 Water Heating 0.58 6.14 0.51 5.76 0.07 0.38 Self Utilization/Flexibility Credit 0 0 West Facing Efficiency Compliance Total 4.81 74.59 3.79 58.51 1.02 16.08 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 5 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 ENERGY USE INTENSITY Standard Design (kBtu/ft 2 - yr )Proposed Design (kBtu/ft 2 - yr )Compliance Margin (kBtu/ft 2 - yr ) Margin Percentage North Facing Gross EUI 1 14.36 12.63 1.73 12.05 Net EUI 2 2.74 2.57 0.17 6.2 East Facing Gross EUI 1 14.36 12.72 1.64 11.42 Net EUI 2 2.74 2.66 0.08 2.92 South Facing Gross EUI 1 14.36 12.56 1.8 12.53 Net EUI 2 2.74 2.5 0.24 8.76 West Facing Gross EUI 1 14.36 12.79 1.57 10.93 Net EUI 2 2.74 2.73 0.01 0.36 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 6 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 5 NA Premium (~18-20%)Fixed Microinverters true 150-270 n/a n/a <=7:12 97.5 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV module type: Premium •PV power electronics: Microinverters •Indoor air quality, balanced fan •IAQ Ventilation System Heat Recovery: minimum 69 SRE and 75 ASRE •IAQ Ventilation System: supply outside air inlet, filter, and H/ERV cores accessible per RACM Reference Manual •IAQ Ventilation System: fault indicator display •Non-standard roof reflectance •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Building air leakage/reduced infiltration •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Duct leakage testing •Low-leakage Air Handling Unit •Recirculation, Demand Control Push Button 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 7 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 4 V067 (3006)3006 1 4 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Status Home Conditioned HVAC System1 3006 9.04 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg) Front Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 0 Front 312.5 100 90 Left Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 90 Left 487.4 48 90 Rear Wall 2x6 Home R-21 Wall w/1 EPS R4 180 Back 499.6 144 90 Right Exterior Wall 2x6 Home R-21 Wall w/1 EPS R4 270 Right 663.1 70 90 Front Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 187.7 17.8 n/a Left Interior Surface 2x6 Home>>__Garage__Garage R-21 Wall n/a n/a 354.2 0 n/a Right Interior Surface 2x Home>>__Garage__Garage R-21 Wall n/a n/a 172.6 0 n/a Roof Home R-0+R-49 BD n/a n/a 3006 n/a n/a Roof 2 __Garage__R-0 Roof Attic n/a n/a 610 n/a n/a Front Exterior Wall __Garage__R-0 Wall 0 Front 187.7 112 90 Left Exterior Wall __Garage__R-0 Wall 90 Left 186.2 16.7 90 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 8 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.17 0.91 No No Attic Home Attic RoofHome Unventilated 4 0.17 0.91 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window Window Front Exterior Wall 2x6 Front 0 1 80 0.28 NFRC 0.22 NFRC Bug Screen Window 2 Window Left Exterior Wall 2x6 Left 90 1 48 0.28 NFRC 0.22 NFRC Bug Screen Window 3 Window Rear Wall 2x6 Back 180 1 144 0.28 NFRC 0.22 NFRC Bug Screen Window 4 Window Right Exterior Wall 2x6 Right 270 1 70 0.28 NFRC 0.22 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft 2)U-factor Door Front Exterior Wall 2x6 20 0.142857 Door 2 Front Interior Surface 2x 17.8 0.285714 Door 3 Front Exterior Wall 112 1 Door 4 Left Exterior Wall 16.7 0.7 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 9 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Home 3006 216 none 0 80%No Slab-on-Grade 2 __Garage__610 41 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall w/1 EPS R4 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / 4 0.051 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Sheathing / Insulation: R-4 Sheathing Exterior Finish: Synthetic Stucco Garage R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 10 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Attic RoofHome Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-49 None / 0 0.02 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-36.0 insul. R-0 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-0+R-49 BD Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required Required 679.4 1.5 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Demand Recirculation Manual Control DHW Heater 1 1 n/a None DHW Sys 1-hers-dhw DHW Heater 1 (1) 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 11 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal) NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 50 Rheem RheemPROH50T2RH 310BM __Garage____Garage____Garage__ RECIRCULATION LOOPS 01 02 03 04 05 Water Heating System Name Number of Recirculation Loops Loop Insulation Thickness (in)Recirculation Loop Location Recirculation Pump Power (W) DHW Sys 1 1 1.5 Conditioned 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heating and cooling system other Heating Component 1 1 Cooling Component 1 1 HVAC Fan 1 Air Distribution System 1 Setback 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 12 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Heating Efficiency Heating Component 1 Central gas furnace 1 AFUE-96.1 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 09 Name System Type Number of Units Efficiency Metric Efficiency EER/EER2/CEER Efficiency SEER/SEER2 Zonally Controlled Mulit-speed Compressor HERS Verification Cooling Component 1 Central split AC 1 EER2/SEER2 13 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEERSEER2 Verified Refrigerant Charge Cooling Component 1-hers-cool Required 275 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 13 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM) Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE Includes Fault Indicator Display? HERS Verification Status SFam IAQVentRpt 1-1 125 0.84 Balanced Yes 75 No Yes 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Plan 4 V067 (3006)Calculation Date/Time:2023-07-05T08:56:28-07:00 (Page 14 of 14) Calculation Description:Title 24 Analysis Input File Name:Beazer CANTERA Plan 4 V067 (3006).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-07-05   08:57:30 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com Andre Pujic Energy Inspectors 2570 South Miller Lane Las Vegas, NV 89117 2023-07-05 09:05:23 702-365-8080 Jody Young Beazer Homes- California 310 Commerce, Suite 150 Irvine, CA 92602 2023-07-05 09:37:39 NA 714-285-2900 7021 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 223-P010073373B-000000000-0000 2023-07-05 09:37:39 CalCERTS inc.