Loading...
Cantera at Coral Mountain TR 31249 BCPR2023-1000i3 cMrnn<<� Plan Type: Building Construction Plan Review Plan No.: BCPR2023-1000 Work Class: Building Construction Plan Review District: City of La Quinta Status: Expired Square Feet: 0.00 Valuation: $0.00 Assigned To: Clayton, Duane Description: CANTERA AT CORAL MOUNTAIN / 2022 CODE UPDATE / SFD x 4 - PLANS 1, 2, 3, AND 4 PLAN 1: 2,179SF PLAN 2: 2,333SF PLAN 3: 2,670SF PLAN 4: 3,006SF BCPR2023-1000 - CANTERA AT CORAL MOUNTAIN REVISION 1 RELOCATION OF HEAT PUMP WATER HEATERS TO GARAGE LOCATIONS FOR ALL PLAN TYPE THIS INCLUDES MODIFICATIONS TO ELECTRICAL, PLUMBING, AND STRUCTURAL FRAMING. ADDITIONALLY, CONDITIONED SPACE FOR PLANS 3 AND 4 REDUCED BY 10SF. 2022 CALIFOR BUILDING CODES. Parcel: 766070010 Main I Address: Cantera At Coral Mountain Main I Zone: Applicant Applicant Contractor Jessica Nicholas Jessica Nicholas Jessica Nicholas 310 Commerce St Suite 150 310 Commerce St Suite 150 310 Commerce St Suite 150 Irvine, CA 92602 Irvine, CA 92602 Irvine, CA 92602 Plan Custom Fields Tract / Subdivision TR 31249 / Cantera at Name Coral Mountain Number of Plan Types 4 Code Edition 2022 Image Corridor Zoning RL Tract Number 31249 Scanned Plan Set 0 Number use 0 if none Are Fire Sprinklers Yes Required? Sound Corridor General Plan ROW. LDR Acreage 4.3 Subdivision Name TR 31249 Legal Description Lot J MB 411/23 TR 31249 Centerlines 92156, 92155, 96873, 96876, 96870, 96869, 96875, 96872, 96871, 96874 Attachment File Name Added On Added By Signature_Gavin_Percy_8/29/2023.jpg 08/29/2023 10:57 Percy, Gavin BCPR2023-1000 - 1ST REVIEW 10/03/2023 12:51 Mendez, Deisy CORRECTION LIST.pdf La Quinta-(BCPR2023-1 000)-PC1 - 10/03/2023 12:51 Mendez, Deisy Cantera Tract.pdf LaQuinta - LAQ23-0159 - 10/03/2023 12:51 Mendez, Deisy BCPR2023-1000 - Invoice 91307 $837.50.pdf BCPR2023-1000 Fire COA.pdf 10/19/2023 15:15 Cox, Chris Construction Plan Set -not approved.pdf 10/19/2023 15:22 Mendez, Deisy La Quinta-BCPR23-1000-PCF-2022 12/05/2023 11:35 Mendez, Deisy Code update only.pdf App Date: 08/29/2023 Exp Date: 08/23/2024 Completed: NOT COMPLETED Approval Expire Date: NOT AVAILABLE Model/Series Name Other Notes Specific Plan Number Is this a revision? City Limits Lot Number Lot Size CODE UPDATE REVIEW No Within La Quinta City Limits J 25349.7 Attachment Group Notes Uploaded via CSS 1ST REVIEW BUILDING CORRECTION LIST Available Online Construction Plan Set REV1/IW PC1APPROVAL June 18, 2025 78-495 Calle Tampico Page 1 of 3 LaQuinta - LAQ23-0159 - 12/05/2023 11:35 Mendez, Deisy REV1 / IW PC1 APPROVAL EMAIL BCPR2023-1000 - Invoice 178729 $810.00.pdf Plan Review Revision Approved_ TR_ 12/05/2023 11:35 Mendez, Deisy REV1 / IW PC1 INVOICE 31249 (BCPR2023-1000) {LAQ23-0159}. msg _ Sequence Sheets - Cantera Ph 12 - 12/13/2023 9:16 Mendez, Deisy sequence sheets 2022.03.01.pdf BCPR2023-1000 - 2ND REVIEW 12/19/2023 4:57 Clayton, Duane PC-2 CORRECTION LIST COLQ CORRECTION LIST.pdf 3RD REVIEW CORRECTION LIST 01/05/2024 14:46 Clayton, Duane Internal Only (WORD).docx 3RD REVIEW CORRECTION LIST.pdf 01/05/2024 14:49 Clayton, Duane PC 3 CORRECTION LIST CALCERTS APPROVED_v2.pdf 01/30/2024 11:22 Mendez, Deisy Available Online Energy Documents PLAN SET (APPROVED)_v4.pdf 01/30/2024 11:22 Mendez, Deisy Available Online Construction Plan Set STRUCTURAL CALCULATIONS 01/30/2024 11:22 Mendez, Deisy Available Online Structural Calculations APPROVED _v2.pdf TRUSS CALCULATIONS 01/30/2024 11:22 Mendez, Deisy Available Online Truss Calculations APPROVED_v2.pdf GEOTECHNICAL REPORT_v2.pdf 01/30/2024 11:22 Mendez, Deisy Available Online Geotechnical Investigation ENERGY REPORT PC4_v2.pdf 01/30/2024 11:22 Mendez, Deisy Available Online Energy Documents REV 1 - METHOD OF COMPLIANCE 04/12/2024 10:17 Molina, Elizabeth Available Online Energy Documents (APPROVE D)_v1.pdf REV 1 - PLAN SET PC1 04/12/2024 10:17 Molina, Elizabeth Available Online Construction Plan Set (APPROVED)_v1.pdf REV 1 - STRUCTURAL CALCULATION; 04/12/2024 10:17 Molina, Elizabeth Available Online Structural Calculations (APPROVE D)_v1.pdf Note Created By Date and Time Created 1. FEES ARE GOOD TO GO Daisy Mendez 01/30/2024 11:24 Invoice No. Fee Fee Amount Amount Paid INV-00004081 Hourly Charge - Interwest Plan Check Engineer 2023 $1,417.50 $1,417.50 Hourly Charge - City Building Staff $700.00 $700.00 Hourly Charge - Interwest Plans Examiner 2023 $230.00 $230.00 Credit Card Convenience Fee $59.44 $59.44 Technology Enhancement Fee $8.00 $8.00 Digital Archiving and Records Management Fee $22.00 $22.00 Total for Invoice lNV-00004081 $2,436.94 $2,436.94 INV-00005876 Credit Card Convenience Fee $5.46 $5.46 Hourly Charge - City Building Staff $218.75 $218.75 Total for Invoice lNV-00005876 $224.21 $224.21 Grand Total for Plan $2,661.15 $2,661.15 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Building Major Review v.1 Requires Re -submit 09/19/2023 10/03/2023 10/19/2023 Yes Yes Item Review Name Department Assigned User Status Assigned Due Completed Date Date Date Building Building Revisions Required 09/19/2023 10/03/2023 10/03/2023 Comments: PC1 Item Review Name Department Assigned User Status Assigned Due Completed Date Date Date Fire Department - Building Cases Office of the Fire Marshal Cox, Chris Approved 09/19/2023 10/03/2023 10/19/2023 June 18, 2025 78-495 Calle Tampico Page 2 of 3 Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Complete Outside Agency Group, Interwest Revisions Required 09/19/2023 10/03/2023 10/03/2023 Comments: PC1 - IW Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Planning - Building Cases Planning/Zoning Criste, Nicole Complete 09/19/2023 10/03/2023 10/13/2023 Comments: Plans substantially conform to SDP submittal. Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Public Works - Building Cases Public Works Yu, Amy Ready for Approval 09/19/2023 10/03/2023 10/03/2023 Comments: Applicant informed over the phone that footprints of houses not changed Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Building Major Review v.2 Requires Re -submit 11/28/2023 12/12/2023 12/19/2023 Yes Yes Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Building Building Clayton, Duane Revisions Required 11/28/2023 12/12/2023 12/19/2023 Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Complete Outside Agency Group, Interwest Approved 11/28/2023 12/12/2023 12/05/2023 Comments: REV1 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Building Major Review v.3 Requires Re -submit 12/27/2023 01/04/2024 01/05/2024 Yes Yes Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Building Building Clayton, Duane Revisions Required 12/27/2023 01/04/2024 01/05/2024 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Building Major Review v.4 Approved 01/24/2024 01/31/2024 01/30/2024 No Yes Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Building Building Clayton, Duane Approved 01/24/2024 01/31/2024 01/30/2024 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Building Revision Review v.1 Approved 03/19/2024 04/02/2024 04/12/2024 No Yes Item Review Name Department Assigned User Status Assigned Due Completed Date Date Date Building (2WK) Building Clayton, Duane Approved 03/19/2024 04/02/2024 04/12/2024 Assigned Due Completed Item Review Name Department Assigned User Status Date Date Date Planning - Building Cases Planning/Zoning Fernandez, Siji Ready for Approval 03/19/2024 04/02/2024 03/21/2024 Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 01/30/2024 11:22 Building Major Review v.1 Receive Submittal 09/19/2023 0:00 10/19/2023 15:22 Building Major Review v.2 Receive Submittal 11/28/2023 0:00 12/19/2023 8:14 Building Major Review v.3 Receive Submittal 12/27/2023 0:00 01/05/2024 14:57 Building Major Review v.4 Receive Submittal 01/24/2024 0:00 01/30/2024 11:22 Building Revision Review v.1 Receive Submittal 03/19/2024 0:00 04/12/2024 10:17 June 18, 2025 78-495 Calle Tampico Page 3 of 3 CAL FIRE — RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT �Cci BILL WEISER -- FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA-CALIFORNIA - 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org October 19, 2023 Attn: Gavin Percy Re: Residential Building Tract Plans — Cantera at Coral Mountain BCPR2023-1000 The building plans you submitted for the above referenced project have been reviewed and approved by the Fire Department with the following conditions. TRACT ACCESS & WATER REQUIREMENTS: ACCESS Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, La Quinta Municipal Code and Riverside County Fire Department Standards. 1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs and/or red painted curbs. 2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key -switch access. Automatic gates shall also have Opticom IR receivers. 3) Approved street signs shall be installed and visible. 4) No Traffic Calming Devices shall be installed. *Future/proposed traffic calming devices require approval by the Office of the Fire Marshal. WATER 1) Fire hydrants shall be installed within 600 feet hose -lay length of the proposed residential units. 2) An observable minimum fire flow shall be present upon testing. 3) Fire hydrant caps shall be in place and marked in accordance with local requirements. 4) Blue roadway reflector shall be installed in the completed roadway to identify the location of all fire hydrants. 5) Hydrant roadway valve boxes shall have their coverplate or lid exposed and easily accessible. PRIOR TO PERMIT RELEASE INSPECTION 1) Individual Tract Home (Production) permits will not be released until a Tract Access/Water inspection has been completed for the affected phase or groupin of f lots. Applicant/Contractor shall be responsible for contacting the Office of the Fire Marshal to schedule inspections. Request for inspections are to be made at least 48 hours in advance and may be arranged by calling 760-777-7131. DEFERRED SUBMITTALS REQUIRED 1) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections. a. Residential Fire Sprinkler permits may be applied for as Master Plan Types. A single Fire Sprinkler Master Plan permit for each different plan type may be individually applied for. Coordinate with the La Quinta Permit Technicians for appropriate application and fee process. GENERAL CONDITIONS 1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be posted on the structure when viewable from the roadway, or at the driveway entrance and maintained visible from both directions of travel. 2) All HOA and Private landscaping shall maintain a minum 3-feet radius clearance around the circumference of fire protection equipment, that includes fire hydrants. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078 Chris Cox — Fire Safety Supervisor DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 BCPR PLAN CHECK CORRECTION LIST (os) DATE: OCTOBER 03, 2023 STATUS: FIRST REVIEW PLAN CHECKED BY: INTERWEST TELEPHONE NUMBER: (760) 777-7002 ADDRESS: CANTERA AT CORAL MOUNTAIN DESCRIPTION: TR31249 APPLICANT: BEAZER HOMES PLAN CHECK #: BCPR2023-1000 This submittal has been checked for compliance with the 2022 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1ST REVIEW 1ST REVIEW CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: -RESPONSE LIST TO CORRECTION LISTS -REVISED PLAN SET -REVISED DOCUMENTS (AS NECESSARY) -TRUSS CALCULATIONS -SOILS FOUNDATION LETTER - CONTRACTOR INFORMATION -CVWD APPROVAL -DEBRIS MANAGEMENT PLAN (BURRTEC) -GRANT DEED -SCHOOL FEE RECEIPT INSTRUCTIONS TO APPLICANT: 1) Provide a response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise original Plans and/or Calculations as necessary. 3) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be electronically signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. Residential Plan Check Correction List Page 1 of 2 SECTION A - GENERAL 1) The City of La Quinta has elected to use Interwest Consulting for plan review of your project. In addition to the comments provided by the City of La Quinta within this correction list please see the attached outside consultant review comments. See Complete Review Comments Attached, for resubmittal please include a separate response sheet for each set of review comments. 2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and electronic signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536. Resubmittals will not be accepted with signatures missing. 3) Provide Planning Division approval for this Project. Please contact Planning Division directly at (760) 777-7195 with questions regarding the following comment(s): a) PENDING REVIEW —REACH OUT TO PLANNING OR MONITOR THE HUB 4) Provide Riverside County Office of the Fire Marshall approval of this project. Contact CHRIS COX directly at (760) 777- 7078 with questions regarding the following comment(s): a) PENDING REVIEW —REACH OUT TO FIRE OR MONITOR THE HUB 5) Provide written evidence of Public Works Division approval of this Project. Contact PUBLIC WORKS directly at (760) 777-7047. a) PENDING REVIEW —REACH OUT TO PW OR MONITOR THE HUB 6) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 65% of the construction materials from landfill for the project. Contact the District Environmental Coordinator directly at (760) 674-1026 for free assistance with the preparation of this plan. 7) Underground electrical service. No person shall construct, install, or place above the surface of the ground any poles, wires, and associated structures, regardless of the use or proposed use of the structure of building to be served thereby. (LQMC §8.03.020) SECTION B — MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide contractor information to complete building permit application form. 3) Provide proof of payment of school fees. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. 4) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be performed when Plans are complete. END CITY REVIEW CORRECTION LIST - CORRECTION LIST CONTINUED BY INTERWEST CONSULTING GROUP ATTACHED As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 October 3, 2023 CITY OF LA QUINTA - FIRST REVIEW Permit No: BCPR2023-1000 Interwest No.: LAQ23-0159 Non -Structural: 2.0-hours Structural: 4.5-hours City of La Quinta Building Department 78-495 Calle Tampico La Quinta, CA 92253 0 r"T INTERWEST A SAFEbuilt COMPANY Plan Review: Revision #1 of Residential - Model for Tract 31249 - Submittal 1 (1) Address: 58th. Ave. & Sidonia Way Interwest Consulting Group has completed a first code compliance review of the following documents on behalf of the City of La Quinta: 1. Drawings: Two copies of following: a. CS-0 through D-9 dated 6/22/22 by Brian Miller b. S-CS through SD7 dated 7/13/23 by Michael Burica C. T24-MM through T24-4.0.1 dated 6/21/23 by Ei Engineering d. M0.0 through MD1.2 dated 7/27/23 by Joseph McCabe e. E1.0 through E4.0 dated 7/31/23 by Edward Borden f. P0.0 through PD1.0 dated 7/06/23 by Joseph McCabe 2. Structural Calculations: PDF copy dated 7/13/23 by Michael Burica 3. Energy Compliance Documentation: Included in plans The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review. Plan review comments follow on the attached list. Please submit an itemized response letter and complete and revised documents with directly to city of La Quinta Building and Safety Department. Sincerely, INTERWEST CONSULTING GROUP Mark Hankinson Sal Kaddorah, PE, MS, CPE Plans Examiner Senior Engineer 1500 S. Haven Ave I Suite 220 Ontario, CA 91761 909.295-3142 INTERWESTGRP.COR Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 1-V122 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 2 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,179 792 87 228 Total Area: 3,286 Building Height: 20'-2" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 2-V123 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 3 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,333 767 102 243 Total Area: 3,445 Building Height: IT-11 1/8" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 3-S812 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 4 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,670 561 33 219 Total Area: 3,483 Building Height: 20'-5" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: I AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 4-V067 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 5 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 3,006 610 57 180 Total Area: 3,853 Building Height: 21'-11" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonia Way 1013123 GENERAL COMMENTS: City of La Quints - First Review Interwest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 6 of 7 G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following comments reference the 2022 California Building Standards Code as amended by the authority having jurisdiction unless otherwise noted. G2. Please respond in writing to each plan review comment by marking this comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the following should be included with each plan review response: • Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s). Briefly explain in writing how the design is intended to comply with the applicable code sections. Please provide a narrative of revisions made outside the plan review comments. Complete and clear responses will expedite the re -check of this project. G3. Please be sure to include on the re -submittal the architect's and /or engineer's stamp, signature, date of signature, and registration number on all sheets of plans depicting structural designed elements and cover sheets of calculations. CBPC 5536.1 and 6735. PLAN REVIEW COMMENTS: BUILDING AND LIFE SAFETY: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments MECHANICAL: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments PLUMBING: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments ELECTRICAL: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) City of La Quin to - First Review 58th. Ave. & Sidonia Way Interwest Project No. LAQ23-0159 1013123 PermitApp: BCPR2023-1000 Page 7 of 7 ENERGY COMPLIANCE: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments CaIGREEN: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments STRUCTURAL: [Sal Kaddorah; skaddorah@interwestgrp.com; (310)383-8725] S1. Please provide a copy of the geotechnical report for the project. S2. The geotechnical engineer of record is to sign and stamp the foundation plans or provide a dated review letter for the project. S3. Provide a copy of the roof truss calculations, including a review verification by the engineer of record. S4. Please update the structural calculations to comply with the 2022 CBC requirements. S5. Please list the solar panel installation, review and approval, under a deferred approval or provide complete solar panel structural calculations and plans for current review. S6. Additional comments may be generated after the above items are provided. Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions. [END] INTERWEST December 5, 2023 CITY OF LA QUINTA - FINAL REVIEW Permit No: BCPR2023-1000 Interwest No.: LAQ23-0159 Non -Structural: 0-hours Structural: 6-hours City of La Quinta Building Department 78-495 Calle Tampico La Quinta, CA 92253 0 1W INTERWEST A SAFEbuilt COMPANY Plan Review: Revision #1 of Residential - Model for Tract 31249 - Submittal 1 (1) Address: 58th. Ave. & Sidonia Way Interwest Consulting Group has completed a FINAL code compliance review of the following documents on behalf of the City of La Quinta: 1. Drawings: Two copies of following: a. CS-0 through D-9 dated 7/20/23 by Brian Miller b. S-CS through SD7 dated 7/13/23 by Michael Burica C. T24-MM through T24-4.0.1 dated 6/21/23 by Ei Engineering d. MO.0through MD1.2 dated 7/27/23 by Joseph McCabe e. E1.0 through E4.0 dated 7/31/23 by Edward Borden f. P0.0 through PD1.0 dated 7/06/23 by Joseph McCabe 2. Structural Calculations: PDF copy dated 10/5/23 by Michael Burica 3. Energy Compliance Documentation: dated 6/21/232 Included in plans and provided on PDF 4. Geotechnical Investigation: PDF dated 1/21/23 by GeoTec. 5. Miscellaneous Documents: PDF of the following: a. Truss calculations dated 8/15/23 by Builders First source. The applicable provisions of the 2022 California Building Standards Code were used as the basis of this review. Sincerely, INTERWEST CONSULTING GROUP Mark Hankinson Plans Examiner 1500 S. Haven Ave I Suite 220 Ontario, CA 91761 Sal Kaddorah, PE, MS, CPE Senior Engineer 909.295-3142 INTERd'ESTGRR.COM Tract31249 code update Tr. 31249 1215123 Plan 1-V122 City of La Quinto - Final Review Interwest Project No. LAQ23-0159 Pe rm i t Ap p: 8 CPR-2023-1000 Page 2 of5 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,179 792 87 228 Total Area: 3,286 Building Height: 20'-2" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: I AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Tract31249 code update Tr. 31249 1215123 Plan 2-V123 City of La Quinto - Final Review Interwest Project No. LAQ23-0159 Pe rm i t Ap p: 8 CPR-2023-1000 Page 3 of5 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,333 767 102 243 Total Area: 3,445 Building Height: 19'-11 1/8" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: I AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N Plan 3-S812 INTERWEST Tract31249 code update Tr. 31249 1215123 City of La Quinto - Final Review Interwest Project No. LAQ23-0159 Pe rm i t Ap p: 8 CPR-2023-1000 Page 4 of5 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,670 561 33 219 Total Area: 3,483 Building Height: 20'-5" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Tract31249 code update Tr. 31249 1215123 Plan 4-VO67 City of La Quinto - Final Review Interwest Project No. LAQ23-0159 Pe rm i t Ap p: 8 CPR-2023-1000 Page 5 of5 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 3,006 610 57 180 Total Area: 3,853 Building Height: 21'-11" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: I AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST DATE: 12/18/2023 STATUS: 2ND REVIEW PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 80325 AVENUE 58 DESCRIPTION: 2022 CODE UPDATE APPLICANT: BEAZER HOMES PLAN CHECK #: BCPR2023-1000 This submittal has been checked for compliance with the 2022 California Residential, Green Building and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1-2 ND SUBMITTAL PLAN SET THIS CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 1— REVISED PLAN THIS CORRECTION LIST WITH RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page 1 of 3 SECTION A - GENERAL 1) The Sheet Index does not reflect actual sheets in plans. Sheets M-02.1 and 54.3 are missing from the plan set. The following sheets need to be added to the sheet index: PD 1.0, P-4.4, P-4.0, P-3.4, P-3.0, P-2.2, P-2.0, P-1.4, P-1.3, P-1.2, M-001, T24-4.01, T24-3.01, T24-2.01, T24-1.01, A3-3.6, F3-1.3, CS-1.1, AND CS1.0. All electrical plan sheets need page numbers and the sheet index updated to reflect the numbered sheets. Sheet D-5 is indicated as not used in the index but is used in the plan set and has detailing on it. SECTION B — PRECISE / SITE PLAN / ZONING 1) No comments. SECTION C - ARCHITECTURAL 1) Provide note on plans: 2x8 nominal blocking, 32 to 39-1/2" above finished floor for grab bar installation, in a minimum of one bathroom, on the entry level of the dwelling, or on the 2"1/3rd floors if no bathroom is located on the 15Y floor (R327). 2) Provide doorbell button, or button control 48" max above exterior floor/landing (R327.1.4). SECTION D - MECHANICAL 1) No comments. SECTION E — ELECTRICAL 1) Note on plans: "Excluding dedicated receptacles and fixture/appliance mounted controls, electrical outlets, switches, and controls, intended for occupant use shall be no more than 48" to top of outlet box, and not less than 15" above finished floor (CRC R327.1.2, EX. 1,2). 2) Provide one island/peninsular receptacle for the first 9sf, or fraction thereof, of counter space and one additional outlet for each additional 18sf or fraction thereof of counterspace (CEC 210.52 (C 1-3) & 210.52(E)(3). 3) Note on plans: A Type I or Type II surge protection device (SPD) shall be provided at or adjacent to dwelling main service panel in accordance with CEC 230.67 & 242. 4) Note on plans: Circuit breaker spaces shall be provided in main service panelboard for heat pump water heaters, space heaters, electric cooktops, and electric clothes dryers (CEC 408.2 (A) & CENC150.0(n, t, u, and v). 5) Please update the code cycle reference to 2022 on the electrical general notes sheet. SECTION F - PLUMBING 1) No comments. SECTION G — ENERGY EFFICIENCY 1) Water heating system. 1. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B below. All electrical components shall be installed in accordance with the California Electrical Code: A. If the designated space is within 3 feet from the water heater, then this space shall include the following: i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater and accessible to the water heater with no obstructions; and ii. Both ends of the unused conductor shall be labeled with the word "spare" and be Residential Plan Check Correction List Page 2 of 3 Ot4a" electrically isolated; and iii. A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit in A above and labeled with the words "Future 240V Use"; and iv. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. B. If the designated space is more than 3 feet from the water heater, then this space shall include the following: Significant Code Changes 2022 9/12 27 October 2022 i. A dedicated 240 volt branch circuit shall be installed within 3 feet from the designated space. The branch circuit shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready"; and ii. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future HPWH installation. The reserved space shall be permanently marked as "For Future 240V use"; and iii. Either a dedicated cold water supply, or the cold water supply shall pass through the designated HPWH location just before reaching the gas or propane water heater; and iv. The hot water supply pipe coming out of the gas or propane water heater shall be routed first through the designated HPWH location before serving any fixtures; and iv. The hot and cold water piping at the designated HPWH location shall be exposed and readily accessible for future installation of an HPWH; and v. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. SECTION H - CALGREEN 1) No comments. SECTION I - STRUCTURAL 1) No comments. SECTION J — SOIL / FOUNDATION 1) No comments. SECTION K - MISCELLANEOUS COMMENTS 1) Inadequate information has been provided in this submittal to calculate fees for this project. Fee calculation will be performed when Plans are complete. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 3 of 3 Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 1-V122 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 2 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,179 792 87 228 Total Area: 3,286 Building Height: 20'-2" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 2-V123 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 3 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,333 767 102 243 Total Area: 3,445 Building Height: IT-11 1/8" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 3-S812 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 4 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 2,670 561 33 219 Total Area: 3,483 Building Height: 20'-5" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: I AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonio Way 1013123 Plan 4-V067 City of La Quinta - First Review Interest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 5 of 7 Occupancy Group: Area (sq. ft.): R3 Garage Porch Patio 3,006 610 57 180 Total Area: 3,853 Building Height: 21'-11" Building Stories: 1 Type of Construction: VB Occupant Load: <10 Sprinklered: Y Valuation: Not Listed Wildland Urban Interface N (WUI) Fire Area? Flood Zone: AE Risk Category: II Site Class (seismic): D Seismic Design Category: D Special Wind Region: N Snow Loads: N INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) 58th. Ave. & Sidonia Way 1013123 GENERAL COMMENTS: City of La Quints - First Review Interwest Project No. LAQ23-0159 Permit App: BCPR2023-1000 Page 6 of 7 G1. The following plan review documents are based on the City of La Quinta Building Regulations. The following comments reference the 2022 California Building Standards Code as amended by the authority having jurisdiction unless otherwise noted. G2. Please respond in writing to each plan review comment by marking this comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. At minimum, the following should be included with each plan review response: • Page / sheet number(s), detail / specification number(s), etc., and include all applicable code section(s). Briefly explain in writing how the design is intended to comply with the applicable code sections. Please provide a narrative of revisions made outside the plan review comments. Complete and clear responses will expedite the re -check of this project. G3. Please be sure to include on the re -submittal the architect's and /or engineer's stamp, signature, date of signature, and registration number on all sheets of plans depicting structural designed elements and cover sheets of calculations. CBPC 5536.1 and 6735. PLAN REVIEW COMMENTS: BUILDING AND LIFE SAFETY: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments MECHANICAL: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments PLUMBING: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments ELECTRICAL: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments INTERWEST Revision#1 of residential - Model for Tract 31249 - Submittal 1 (1) City of La Quin to - First Review 58th. Ave. & Sidonia Way Interwest Project No. LAQ23-0159 1013123 PermitApp: BCPR2023-1000 Page 7 of 7 ENERGY COMPLIANCE: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments CaIGREEN: [Mark Hankinson; mhankinson@interwestgrp.com; 520.733.0266] No Comments STRUCTURAL: [Sal Kaddorah; skaddorah@interwestgrp.com; (310)383-8725] S1. Please provide a copy of the geotechnical report for the project. S2. The geotechnical engineer of record is to sign and stamp the foundation plans or provide a dated review letter for the project. S3. Provide a copy of the roof truss calculations, including a review verification by the engineer of record. S4. Please update the structural calculations to comply with the 2022 CBC requirements. S5. Please list the solar panel installation, review and approval, under a deferred approval or provide complete solar panel structural calculations and plans for current review. S6. Additional comments may be generated after the above items are provided. Please contact the listed reviewers between 9:00 A.M. and 4:00 P.M., M-F, with any questions. [END] INTERWEST DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST DATE: 12/18/2023 STATUS: 3RD REVIEW PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 80325 AVENUE 58 DESCRIPTION: 2022 CODE UPDATE APPLICANT: BEAZER HOMES PLAN CHECK #: BCPR2023-1000 This submittal has been checked for compliance with the 2022 California Residential, Green Building and Energy Codes, and the City of La Quinta Municipal Code. APPLICANT: The following items are being returned to you for correction: 1— 3RD SUBMITTAL PLAN SET THIS CORRECTION LIST BUILDING DEPARTMENT STAFF: DO NOT accept any resubmittal unless ALL of the following items are included: 1— REVISED PLAN THIS CORRECTION LIST WITH RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page 1 of 3 SECTION A - GENERAL 1) A response list is required with all resubmittals. Future submittals without response list for corrections will be returned as incomplete submittals. 2) The plan set submitted is the same as the previous submittal and does not resolve the requested corrections. Refer to drawing date and revision dates on 311 submittal plan. Be sure to cloud all correction items on plan set for your next submittal with the appropriate delta number. Please address all previous corrections from the 2"d review. See below. 3) The Sheet Index does not reflect actual sheets in plans. Sheets P-2.2, M-02.1 and 54.3 are missing from the plan set. The following sheets need to be added to the sheet index: PD 1.0, P-4.4, P-4.0, P-3.4, P-3.0, P-2.2, P-2.0, P-1.4, P-1.3, P- 1.2, M-001, T24-4.01, T24-3.01, T24-2.01, T24-1.01, A3-3.6, F3-1.3, CS-1.1, AND CS1.0. All electrical plan sheets need page numbers and the sheet index updated to reflect the numbered sheets. Sheet D-5 is indicated as not used in the index but is used in the plan set and has detailing on it. Comment remains — Check entire plan set for missing pages and ensure sheet index includes all pages in the plan set. SECTION B — PRECISE / SITE PLAN / ZONING 1) No comments. SECTION C - ARCHITECTURAL 1) PC 2: Provide note on plans: 2x8 nominal blocking, 32 to 39-1/2" above finished floor for grab bar installation, in a minimum of one bathroom, on the entry level of the dwelling, or on the 2nd/3rd floors if no bathroom is located on the 1ST floor (13327). 2) PC 2: Provide doorbell button, or button control 48" max above exterior floor/landing (R327.1.4). SECTION D - MECHANICAL 1) No comments. SECTION E — ELECTRICAL 1) Note on plans: "Excluding dedicated receptacles and fixture/appliance mounted controls, electrical outlets, switches, and controls, intended for occupant use shall be no more than 48" to top of outlet box, and not less than 15" above finished floor (CRC R327.1.2, EX. 1,2). 2) Provide one island/peninsular receptacle for the first 9sf, or fraction thereof, of counter space and one additional outlet for each additional 18sf or fraction thereof of counterspace (CEC 210.52 (C 1-3) & 210.52(E)(3). 3) Note on plans: A Type I or Type II surge protection device (SPD) shall be provided at or adjacent to dwelling main service panel in accordance with CEC 230.67 & 242. 4) Note on plans: Circuit breaker spaces shall be provided in main service panelboard for heat pump water heaters, space heaters, electric cooktops, and electric clothes dryers (CEC 408.2 (A) & CENC150.0(n, t, u, and v). 5) Please update the code cycle reference to 2022 on the electrical general notes sheet. SECTION F - PLUMBING 1) No comments. Residential Plan Check Correction List Page 2 of 3 Ot4a" SECTION G — ENERGY EFFICIENCY 1) Water heating system. 1. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B below. All electrical components shall be installed in accordance with the California Electrical Code: A. If the designated space is within 3 feet from the water heater, then this space shall include the following: i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater and accessible to the water heater with no obstructions; and ii. Both ends of the unused conductor shall be labeled with the word "spare" and be electrically isolated; and iii. A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit in A above and labeled with the words "Future 240V Use"; and iv. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. B. If the designated space is more than 3 feet from the water heater, then this space shall include the following: Significant Code Changes 2022 9/12 27 October 2022 i. A dedicated 240 volt branch circuit shall be installed within 3 feet from the designated space. The branch circuit shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready"; and ii. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future HPWH installation. The reserved space shall be permanently marked as "For Future 240V use"; and iii. Either a dedicated cold water supply, or the cold water supply shall pass through the designated HPWH location just before reaching the gas or propane water heater; and iv. The hot water supply pipe coming out of the gas or propane water heater shall be routed first through the designated HPWH location before serving any fixtures; and iv. The hot and cold water piping at the designated HPWH location shall be exposed and readily accessible for future installation of an HPWH; and v. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. SECTION H - CALGREEN 1) No comments. SECTION I - STRUCTURAL 1) No comments. SECTION J — SOIL / FOUNDATION 1) No comments. SECTION K - MISCELLANEOUS COMMENTS 1) Inadequate information has been provided in this submittal to calculate fees for this project. Fee calculation will be performed when Plans are complete. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 3 of 3 10/3/23, 12:51 PM Invoice 1w INTERWEST A SAFEbwtt COMPANY INVOICE #91307 October 3, 2023 Jurisdiction No. BCPR2023-1000 Interwest Job No. LAQ23-0159 Bill to: City of La Quinta Remit to: Interwest Consulting Group Direct questions to: Attention Danny Castro P.O. Box 301069 Erica Cuevas Design & Development Director Los Angeles, CA 90030-1069 (970) 568-5034 78495 Calle Tampico ecuevas@interwestgrp.com La Quinta, CA 92253 Professional services for the period September 1 through October 3, 2023 RESIDENTIAL- BCPR2023-1000 - 80325 AvENUE 58 - LAQ23-0159 Tr. 31249 Invoice Total $837.50 Emplovee Title Dav Hours Rate Total Mark Hankinson ICC Certified Plans Examiner 9/25 2 $115.00 $230.00 Sal Kaddorah Plan Check Engineer 10/2 4.5 $135.00 $607.50 Labor 6.5 $837.50 https://interwest.lucidbilling.com/invoices/print 1 /1 rw INTERWEST A SAFEbullf COMPANY Bill to: City of La Quinta Attn Castro, Danny Design and Development Director 78-495 Calle Tampico La Quinta, CA 92253 Remit to: Interwest Consulting Group P.O. Box 301069 Los Angeles, CA 90030-1069 Invoice #178729 December 5, 2023 Direct questions to Erica Cuevas ecuevas@interwestgrp.com Professional services for the period December 4, 2023 through December 4, 2023 Residential - BCPR2023-1000 - 80325 Avenue 58 - LAQ23-0159 Invoice Total (Please pay this amount) , $810.00 Employee Title Hours Rate Total Sal Kaddorah Plan Check Engineer 6.00 $135.00 $810.00 Labor 6.00 $810.00 Sal Kaddorah LAQ23-0159 Residential - BCPR2023-1000 - 80325 Avenue 58 - LAQ23-0159 Day Description 12/4/2023 LAQ23-0159 APPROVED Hours 6.00 Total 6.00 1ofI