FRSS2024-0078BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT Qa�fra 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ta CALIFORNIA Permit Type: Fire Sprinkler System - Residential - 13D Owner: Permit Number: FRSS2024-0078 Applicant: Property Address: 79242 TOM FAZIO LN APN: 766042001 Contractor: Legal Description Lot 7 MB 249/1 TR 27728 Property Zoning: RL, 7 Valuation: $0.00 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 05/13/2024 ISSUED DATE: Ruben Hernandez 8085 E. Crystal Drive, Anaheim, CA 92807 Ruben Hernandez / 786965 8085 E. Crystal Drive, Anaheim, CA 92807 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/5/25 1:59 pm Page 1 of 3 BUILDING PERMIT Permit Type: Fire Sprinkler System - Residential -13D Permit Number: FRSS2024-0078 Property Address: 79242 TOM FAZIO LN Design and installation of a new fire sprinkler system 7)nstruction Dot; Number of Sprinkler 38 Building Square Feet - 4215 Zoning RL Heads Protected General Plan LDR City Limits Within La Quinta Limits Subdivision Name TR 27728 Lot Number 7 Lot Size 3481.07 Centerlines 96257 Truck Routes Legal Description Lot 7 MB 249/1 TR 27728 Type Group Sq Ft Value Invoice No. Fee Fee Amount Amount Paid INV-00006771 Fire - Sprinkler System - Single Family Detached 1 $458.00 $458.00 Digital Archiving and Records Management Fee $23.00 $23.00 Technology Enhancement Fee $8.00 $8.00 Credit Card Convenience Fee $12.22 $12.22 Total for InvoiceINV-00006771 $501.22 $501.22 NOT INVOICED Digital Archiving and Records Management Fee $23.00 $0.00 Total for Invoice NOT INVOICED $23.00 $0.00 Grand Total for Permit $524.22 $501.22 Workflow Step / Action Name Action Type Start Date End Date Review v.1 05/13/2024 0:00 05/22/2024 17:55 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Review v.1 Receive Submittal 05/13/2024 0:00 05/22/2024 17:55 Revisions v.1 07/15/2024 0:00 07/19/2024 16:45 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Revision Review v.1 Receive Submittal 07/15/2024 0:00 07/19/2024 16:45 Fire Inspections v.1 06/19/2024 10:33 01/07/2025 10:53 ---------------------------------------------------------------------------------------------------------------------------------------- OH Rough Piping (RES) v.1 Inspection 06/19/2024 10:33 06/28/2024 17:24 ---------------------------------------------------------------------------------------------------------------------------------------- OH Hydro (Res) v.1 Inspection 06/19/2024 10:34 07/12/2024 19:26 ---------------------------------------------------------------------------------------------------------------------------------------- Fire Sprinkler Final 13D v.1 Inspection 12/27/2024 9:39 01/07/2025 10:53 Printed: 9/5/25 1:59 pm Page 2 of 3 BUILDING PERMIT Permit Type: Fire Sprinkler System - Residential -13D Permit Number: FRSS2024-0078 Property Address: 79242 TOM FAZIO LN Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildinq official. Printed: 9/5/25 1:59 pm Page 3 of 3 711111W777W SHEET INDEXoasrsx.xo.sr.wnox a.: RESIDENTIAL FIRE SYSTEMS INC. HIT =17 YETO�SOUR' R� F-ED 111IN-1. -Y----AT.Y- VICINITY MAP STONEFIELD DEVELOPMENT 2-3 AVENIM ­0 DE WATER FLOW INFO. SCOPE OF WORK ................... -.N- RI ll�E -E-A--1 SEE RCCE ON FS-02 PROJECT DATA eq a AIEI -11 1-11 o N _N -L ­L.. I -=) m F ~~ LOT7'THsOUAnnY TOM FAZ|OLANE SOUTH SITE PLAN 13D)Notes. T.. T. L u Lt .—I LIND BEDROOM 3 N� BEDROOM E, SECTION FLOOR PLAN Ll 114 RESIDENTIAL SIR —ER OBSTRUCTION TABL I FICU- NFPA -to =N 1�— RESIDENTIAL FIRE SYSTEMS INC. s. aeon wana RRr . vtE —, ixs I—E-1 RE—.- 77 =%� STONEFIELD DEVELOPMENT 1111AV�,_ NCAZA — 'HYS—LICALLY —ED SYSTEM' TO E SO H FYDRAULICALLY—EDDYSTE D C"-4 Lu W c" z 04 co') 6 9 LL 0 F- 'too 0 04 'Rt 04 0) 19MAN 100004MIN104 SHEET INDEX 11N. —N RESIDENTIAL FIRE SYSTEMS INC. HIT =17 YETO�SOUR, R� F-ED 111IN-1. -Y----AT.Y- VICINITY MAP STONEFIELD DEVELOPMENT 23333 AVENIEA L C— COTO DE C— CA SCS79 WATER FLOW INFO. SCOPE OF WORK ................... NT__,_El-ll-= XRT' � Ll_IlII.Nl-- SEE RCCE ON FS-02 PROJECT DATA T I � 6. U � C xrpra SOUTH o. • JAS-BU PROJECT TEAM l=- '!ELTo A -- IN I—IN R111111 LICENSE STAMP DATA AND DNITEI. INCJ- - -44 .11— F ~~ LOT7'THsOUAnnY TOM FAZ|OLANE SOUTH SITE PLAN 13D)Notes. T.. T. L F-� BEDROOM 3 .-I LIND BEDROOM 11 7�� d - - SECTION FLOOR PLAN Ll 114 RESIDENTIAL SIR -ER OBSTRUCTION TABL I FICU- NFPA "M -to =N 1�- RESIDENTIAL FIRE SYSTEMS INC. _0 TEL -Tff A =LEED�".­=loRFE=.T- 77 JAS-B 'E--Nl-R---E STONEFIELD DEVELOPMENT ,-AVE-LA CAZA HYDRAULICALLY -ED SYSTEM' COTO DE .M. SOUTH FYDRAULICALLY-EDSYSTEM of 0 <N CN c) I LuW c', z 04 04 0) 6 9 LL 0 F- 'too 0 04 'Rt 04 0) CAL FIRE — RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT �Cci BILL WEISER - FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA-CALIFORNIA - 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7131 • www.rvcfire.org May 22, 2024 Residential Fire Systems 8085 E. Crystal Drive Anaheim, CA 92807 engineering@resfire.com Re: Residential Fire Sprinkler Plan Review — LOT 7 - THE QUARRY FRSS2024-0078 (79242 TOM FAZIO LN SOUTH LA QUINTA, CA 92253) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by emailing FireBusinessMail@laquintaca.gov. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Lucero Ihiguez - Fire Safety Specialist RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD a�Cv a�u.cV b THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. — CALIFORNIA — INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 79242 TOM FAZIO LN S, La Quinta PERMIT#: FRSS2024-0078 AT ED: 05/22/24 DESCRIPTION: LOT 7 - THE QUARRY CONTRACTOR: RESIDENTIAL FIRE SYSTEMS INC HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final EF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final EF SPRAY BOOTHS FIRE CODE PERMIT(S) Installation OUTDOOR PUBLIC EVENT Air flow test SPEC. AMUSEMENT STRUCTURE Mechanical interlock TENT/CANOPY Extinguishing system PYROTECHNIC Fire alarm connection OPEN FLAME DEVICE Final E F FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION REQUEST FireBusinessMail(a)laquintaca.gov INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections email: FireBusinessMail(cillaguintaca.gov B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: FRSS2024-0078 THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. HIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION REQUEST FireBusinessMail(cDlaguintaca.gov S A Senju Sprinkler Model RC-RES K-Factor: 4.9 SIN: SS8464 Residential Lead Free Flat Concealed Sprinkler, Pendent C &US LISTED I NSF/ANSI/(AN 61 &372 EU O's GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push -on and/or thread -on, thread -off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar12) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. www.senjusprinkler.com Page 1 of 8 Document No.U085168 • 02-08-2021 WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. TECHNICAL DATA • Approvals: 0 cULus Listed • UL-EU Listed (162°F (72°C) only) • NSF/ANSI/CAN 61, NSF/ANSI 372 • Sprinkler Identification Number (SIN): SS8464 • Maximum Working Pressure: 175psi (12.1bar) • Discharge Coefficient (Nominal K-Factor): 0 K = 4.9 GPM/psi1/2 (70.6 LPM/bars/2) • Temperature Rating: • 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate • 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate • Color Code (Sprinkler) • 162°F (720C): Uncolored • 205OF (96°C): White • Color Code (Cover Plate) • 140°F (60°C): No Mark • 162°F (72°C): White -Colored Mark • Vertical Adjustment: 1/2 inch (12.8 mm) • Cover Plate Finishes: 0 Standard Finishes: White, Ivory, Beige, Brown, Black, Nickel, Wood Grain o Custom Finishes: Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. • Physical Characteristics: Ref. Figures 1 and 1.1 2-1/16" (652mm) a Lot No. Year of Manufacture SIN: SS8464 1-K-Factor: K4.9 4 Temperature Rating: 162°F/72 °C s or 205'F/96 °C z UL Mark B Control No: 6P37 ALS Mark: NSF 61/372 RES SPKR T Body (Copper Alloy) Deflector (Phosphorus Bronze) Gasket 2-518" (068mm) Meta,(PTF( a Fusible Metal (Solder) or 3-1/4" (083mm) s Heat Collector (Copper) or 2-5/8" square (o68mm 6 Cover Plate Assembly Figure 1: Model RC-RES K = 4.9 Marking (Deflector) Cover Plate Sprinkler (Top View) (Bottom View) Figure 1.1: Marking (Color Code) Ling: 162°F/72 °C or 205 °F/96 °C www.senjusprinkier.com Page 2 of 8 Document No.U085168 • 02-08-2021 OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) y Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge Figure 2: Operation Process (For illustrative purposes only) DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. Notes Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13D, 13R, or 13) must be kept as few as possible while observing all guidelines relating to obstructions and spacing. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. www.senjusprinkler.com Page 3 of 8 Document No.U085168 • 02-08-2021 Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: 1. Chlorine ion and Chloride environment Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non -Fire conditions or Not Operating when exposed to an actual fire. 2. Sprinkler system piping with Copper Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) — Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. • A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. www.senjusprinkler.com Page 4 of 8 Document No.U085168 • 02-08-2021 Table A. NFPA 13D & 13P Wet Pipe Hydraulic Design Criteria for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Maximum Ordinary Temperature Intermediate Temperature Coverage Rating 1620F (72°C) Rating 205`F (96°C) Minimum Area(a) Spacing Deflector to Installation Spacing Flow(b)GPM Pressure" Flow(b)GPM Pressure" Ft. x Ft. Ft. Ceiling 9 T Type Ft. (m) (m x m) (m) (LPM) PSI (bar) (LPM) PSI (bar) 12 x 12 12 13 7.0 13 7.0 Smooth (3.7 x 3.7) (3.7) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8 to 7/8 Inches. 14 x 14 14 13 7.0 13 7.0 (4.3 x 4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per 16 x 16 16 13 7.0 13 7.0 NFPA 13D, Concealed 8 (4.9 x 4.9) (4.9) (49.2) (0.48) (49.2) (0.48) 13R or 13. Installed in (2.4) 18 x 18 18 17 12.0 17 12.0 (5.5 x 5.5) (5.5) (64.4) (0.83) (64.4) (0.83) beam 3/8 to 7/8 inches below bottom 20 x 20 20 21 18.4 21 18.4 (6.1 x 6.1) (6.1) (79.5) (1.27) (79.5) (1.27) of beam. a. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. b. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non -operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ft•lbs (9.5 to 19.0 N•m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Removal Tool for RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. www.senjusprinkler.com Page 5 of 8 Document No.U085168 • 02-08-2021 Installation Steps Step 1: The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2: With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3: If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Correct Incorrect Figure 3: Installation Figure 4: Ratchet & Socket Step 4: Use the Cap Removal Tool for RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Cap Removal Tool www.senjusprinkler.com Hook Up ary 1 0 Step 1 Step 2 Figure 5: Protective Cap Removal Page 6of8 Pull down Step 3 Document No.U08S]68 • 02-08-2021 2-5/8' (068mm) or 3-1/4- (083mm) or 2-5/8" sauare (o68mm) Figure 6: Installation (Cover Plate Assembly) Incorrect Correct Incorrect Figure 7: Installation (Correct and Incorrect) CARE & MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. Notes Wet pipe sprinkler systems must be maintained at a minimum temperature of 40oF / 4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non -operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non - factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. www.senjusprinkler.com Page 7 of 8 Document No.U085168 • 02-08-2021 Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over -tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. LIMITED WARRANTY For details of warranty, refer to Sales Contract. ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler • Model: RC-RES SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 205OF (96°C) Cover Plate Assembly • 2-5/8 inch (#8mm) or 3-1/4 inch (�83mm) or 2-5/8 inch square (❑68mm), Order separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. White Ivory Beige Standard Brown Finishes Black Nickel Copper Wood Grain Custom I Finishes Custom Custom Color Pattern 2-5/8" Round, 140°F O O - - - - - - O O 3-1/4" Round,140°F O O O O O O O O O O 2-5/8" Square, 140°F O - - - - - - - O O 2-5/8" Round, 162°F O - - - - - - - O O 3-1/4" Round, 162°F O O O O O - - O O O 2-5/8" Square, 162°F O - - - - - - - O O Tools & Accessories • Socket NR-H for use with a 3/8" drive ratchet (not included) • Socket NR-H Plastic for use with a 1/2" drive ratchet (not included) • Cap Removal Tool for RC • Cover Plate Installation Tool www.senjusprinkler.com Page 8 of 8 Document No.U085168 • 02-08-2021 Victaulic° FireLockT" Series FL-RES Residential Pendent and Recessed Pendent, ✓otaulic K3.0 (4.3)7 K4.9 (7.0)7 K5.6 (8.0)9 K6.9 (9.9) 43.01 0" T 'IT' 1.0 PRODUCT DESCRIPTION RESIDENTIAL PENDENT/RECESSED PENDENT SPRINKLERS SIN V3010 V2740 V5610 V3426 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTORI 3.0 I m ./4.2 S.I. 4.9 I m ./7.1 S.I. 5.6 I m ./8.1 S.I. 6.91 m ./9.9 S.I. CONNECTION 1/2" NPT/15 mm 1/2" NPT/15 mm 1/2" NPT/15 mm 3/4" NPT/20 mm MAX. WORKING PRESSURE 175 si (1200 kPa) 175 psi (1200 kPa) 175 psi (1200 kPa) 175 psi (1200 kPa) GLOBE RE -DESIGNATION GL3010 — GL5610 — GLOBE EQUIVALENT — GL4910 — — AVAILABLE WRENCHES SPRINKLER V27 Recessed V27 Open End V56 Recessed V56 Open End V34 Recessed V34 Open End V3010 ■ ■ V2740 ■ ■ V5610 ■ ■ V3426 ■ ■ Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. Operating Pressure: UL: 7psi/48 kPa/.5 bar Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. vi^F�.dir - 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. 1 ✓ctaulic victaulic.com 2.0 CERTIFICATION/LISTINGS Max. Coverage Area Deflector to Listing Agency/ Approved Width X Ceiling/ Mounting Minimum Nominal K Factor Temperature Ratings Length Flow Pressure Adjustment Surface Distance Spacing Ft. x Ft GPM PSI in in Ft. SIN Imperial S.I 2 155°F/68°C 175°F/790C 200°F/930C m x m Umin kPa mm (mm) m 12 x 12 8 7.1 3.7 x 3.7 30.3 49 1/2 V3010 3.0 4.2 cULus EU cULus cULus 14 x 14 10 11.1 15 4.3 x4.3 37.8 76.5 12 x 12 13 7.0 3.7 x 3.7 49.2 48 Smooth Ceilings 14 x 14 13 7.0 4.3 x 4.3 49.2 48 1/2 and 3/4 Recessed 15 and 20 tion See Installation 16 x 16 13 7.0 V2740 4.9 7.1 cULus cULus N/A 4.9 x 4.9 49.2 48 18 x 18 17 12.0 Smooth Ceilings 5.5 x 5.5 64.3 83 Exposed 20 x 20 20 16.7 1/2 Max. 4 (101.6) 6.1 x6.1 75.7 115 15 Beamed Ceilings 12 x 12 15 7.2 3.7 x 3.7 57 50 Adjacent 8 16 x 16 19 11.5 per NFPA 13, 13D, 2.4 4.9 x4.9 72 79 1/2 or 13R V5610 5.6 8.1 cULus NA N/A 15 as appropriate 18 x 18 21 14.1 5.5 x 5.5 79 97 Beamed Ceilings 20 x20 24 18.4 6.1 x 6.1 91 127 In Beam 14 Max. Beam Depth 12 x 12 20 8.4 3.7 x 3.7 75.7 58 Recessed in Beam: 14 x 14 8.4 20 See Installation 4.3 x4.3 75.7 58 detail 16 x 16 20 8.4 V3426 6.9 9.9 cULus cULus N/A 1/2 and 3/4 4.9 x 4.9 75.7 58 15 and 20 18 x 18 20 8.4 5.5 x 5.5 75.7 58 20 x 20 22 10.2 6.1 x 6.1 83.3 70 NOTE • Listings and approval as of printing. 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 2 ✓otaulillr 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze '/�6711 mm Bulb Nominal Diameter: 3.Omm Nominal make -in Load Screw: Bronze Frale Pip Cap: Bronze Pip cap andspring seal2Y47 Spring Seal Assembly: PTFE coated Beryllium nickel alloy B57mm Frame: Brass Load screLodgement Spring: Stainless Steel Deflec Installation Wrench: Ductile iron 28 mm Sprinkler Frame Finishes: V3010 • Plain brass • Chrome plated • White polyester painted '/6711 mm • Flat black polyester painted Nominal make -in • Custom polyester painted Frame Lodgement spring a NOTE Pip cap and 2g/g°/ • For cabinets and other accessories refer to separate sheet. spring seal 60 mm Bulb Load screw Deflector Frame Pip cap and spring seal — Load screw Deflector 1Y67 27 mm V2740 'f,6'/11 mm Nominal make -in 8a/% 2Y47 57 mm V/47 32 mm V5610 '/2.'/13 mm Nominal make -in Frame I I i Lodgement spring yam. Pip cap and spring seal Bulb Load screw Deflector 36 mm V3426 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 3 21/27 63 mm ✓ctaulicr 4.0 DIMENSIONS 23/8"/60 mm 2751 mm Hole in ceiling /873 mm Min. 1/8716 mm Max. 11/4"/32 mm Min. 13/4744 mm Max. 21 A67 75 mm V3010 23/e760 mm 2751 mm Hole in ceiling 1725 mm Max. (3/4" Adj.) f 3/4"/19 mm Max. (1/21. Adj.) /476 mm Min. I _ P'/,6Y43 mm Max. 215/�6/ 13/�6/30 mm Min. (Yz° Adj.) 75 mm 15A6"/24 mm Min. (3/4" Adj.) V2740 Typical ceiling Finished surface ceiling Finished surface 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 4 ✓otaulicr virfMnlir rnm 4.0 DIMENSIONS (CONTINUED) Y873 mm Min. 6/8716 mm Max. 2/8760 mm 2751 mm Hole in ceiling Typical ceiling surface 1 Y4732 mm Min. 18/4744 mm Max. 2"A67 75 mm V5610 23/8"/60 mm 2751 mm Hole in ceiling 7/8722 mm Max. (1/4" Adj.) 'A716 mm Max. (Yz" Adj.) %873mm Min. W,";:; Typical ceiling y 1%729 mm Min. "'�13/8 /34 mm Min. (Yz" Adj.) Finished surface 178747 mm Max. 21 /16"/ 75 mm V3426 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 5 ✓otaulicr victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS A WARNING Read and understand all instructions before attempting to install y any Victaulic products. • Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from-670F/-550C. User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, as well as Victaulic performance, maintenance, Victaulic reserves the right to change product specifications, designs and standard safety, and warning instructions. Nothing in this or any other document, nor any verbal equipment without notice and without incurring obligations. recommendation, advice, or opinion from any Victaulic employee, shall be deemed to Installation alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions Reference should always be made to the Victaulic installation handbook or installation of sale, installation guide, or this disclaimer. instructions of the product you are installing. Handbooks are included with each shipment Intellectual Property Rights of Victaulic products, providing complete installation and assembly data, and are available No statement contained herein concerning a possible or suggested use of any material, in PDF format on our website at www.victaulic.com. product, service, or design is intended, or should be constructed, to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual Trademarks property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic and all other Victaulic marks are the trademarks or registered trademarks of or patent applications for articles and/or methods of use in the United States and/or other Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. countries. 43.01 16382 Rev C Updated 03/2023 © 2023 Victaulic Company. All rights reserved. victaulic.com 6 ✓ctauliiic®