BRES2019-0330 Title 24CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 1 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
GENERAL INFORMATION
01 Project Name An Apartment Complex for Nispero Properties, Inc
02 Calculation Description Title 24 Analysis
03 Project Location 51-480 Desert Club Dr / North bldg
04 City La Quinta, CA 05 Standards Version Compliance 2017
06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.3.1 (1019)
10 Building Type Multifamily 11 Front Orientation (deg/Cardinal)90
12 Project Scope Newly Constructed 13 Number of Dwelling Units 8
14 Total Cond. Floor Area (ft2)7448 15 Number of Zones 8
16 Slab Area (ft2)3724 17 Number of Stories 2
18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available No
20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)10.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
.
ENERGY USE SUMMARY
04 05 06 07 08
Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 0.57 0.54 0.03 5.3%
Space Cooling 88.06 75.50 12.56 14.3%
IAQ Ventilation 2.49 2.49 0.00 0.0%
Water Heating 22.75 33.75 -11.00 -48.4%
Photovoltaic Offset ----0.00 0.00 ----
Compliance Energy Total 113.87 112.28 1.59 1.4%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•Cool roof
•Window overhangs and/or fins
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
BRES2019-0330 – NORTH
BUILDING / 51480 DESERT
CLUB DR
8,319SF MULTI-FAMILY
8-UNIT APARTMENT
BUILDING WITH 1,855SF
GARAGE [VB/R-2 + S-1
OCC/40-OL/ CLASS
A-FR/13R SPRINKLER
SYSTEM] THIS PERMIT
DOES NOT INCLUDE SITE
LIGHTING, TRASH
ENCLOSURE, CARPORTS
OR SIGNAGE. 2016
CALIFORNIA BUILDING
CODES.
9/6/2022
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 2 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building-level Verifications:
•High quality insulation installation (QII)
•IAQ mechanical ventilation
Cooling System Verifications:
•-- None --
HVAC Distribution System Verifications:
•Duct Sealing
Domestic Hot Water System Verifications:
•-- None --
ZONE INFORMATION
01 02 03 04 05
Zone Name Zone Type Zone Floor Area (ft2)Avg. Ceiling Height Number of Dwelling Units
UNIT 105 Conditioned 931 9 1
UNIT 106 Conditioned 931 9 1
UNIT 107 Conditioned 931 9 1
UNIT 108 Conditioned 931 9 1
UNIT 205 Conditioned 931 9 1
UNIT 206 Conditioned 931 9 1
UNIT 207 Conditioned 931 9 1
UNIT 208 Conditioned 931 9 1
DWELLING UNIT INFORMATION
01 02 03
Dwelling Unit Name Dwelling Unit Type Zone
DwellingUnit 105-(1/1)U-105 UNIT 105
DwellingUnit 106-(1/1)U-106 UNIT 106
DwellingUnit 107-(1/1)U-107 UNIT 107
DwellingUnit 108-(1/1)U-108 UNIT 108
DwellingUnit 205-(1/1)U-205 UNIT 205
DwellingUnit 206-(1/1)U-206 UNIT 206
DwellingUnit 207-(1/1)U-207 UNIT 207
DwellingUnit 208-(1/1)U-208 UNIT 208
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 3 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
DWELLING UNIT TYPES
01 02 03 04 05 06 07
Name CFA (ft2)
Number of
Bedrooms
Number in
Building Space Conditioning Systems Assigned DHW System Name IAQ Vent Fan Name
U-105 931 2 1 DwellingUnit 105 | :Heat Pump System 1:Distribution
System 1:HVAC Fan System 1:2:3 DHW System 1 Default Minimum IAQ Fan
U-106 931 2 1 DwellingUnit 106 | :Heat Pump System 2:Distribution
System 2:HVAC Fan System 2:2:3 DHW System 2 Default Minimum IAQ Fan
U-107 931 2 1 DwellingUnit 107 | :Heat Pump System 3:Distribution
System 3:HVAC Fan System 3:2:3 DHW System 3 Default Minimum IAQ Fan
U-108 931 2 1 DwellingUnit 108 | :Heat Pump System 4:Distribution
System 4:HVAC Fan System 4:2:3 DHW System 4 Default Minimum IAQ Fan
U-205 931 2 1 DwellingUnit 205 | :Heat Pump System 5:Distribution
System 5:HVAC Fan System 5:2:3 DHW System 5 Default Minimum IAQ Fan
U-206 931 2 1 DwellingUnit 206 | :Heat Pump System 6:Distribution
System 6:HVAC Fan System 6:2:3 DHW System 6 Default Minimum IAQ Fan
U-207 931 2 1 DwellingUnit 207 | :Heat Pump System 7:Distribution
System 7:HVAC Fan System 7:2:3 DHW System 7 Default Minimum IAQ Fan
U-208 931 2 1 DwellingUnit 208 | :Heat Pump System 8:Distribution
System 8:HVAC Fan System 8:2:3 DHW System 8 Default Minimum IAQ Fan
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 4 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
Wall-n-F UNIT 105 Wall new 90 Front 232 37.5 90
Wall-n-L UNIT 105 Wall new 180 Left 383 46 90
Wall-n-B UNIT 105 Wall new 270 Back 205 64 90
Interior Wall-n to UNIT 106 UNIT 105>>UNIT 106 Wall Int R0 n/a n/a 384 0 n/a
Interior Wall-n to WH Room 1 UNIT 105>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Wall-n-F 2 UNIT 106 Wall new 90 Front 230 37.5 90
Wall-n-B 2 UNIT 106 Wall new 270 Back 203 64 90
Wall-n-R UNIT 106 Wall new 0 Right 119 14 90
Interior Wall-n to UNIT 107 UNIT 106>>UNIT 107 Wall Int R0 n/a n/a 265 0 n/a
Interior Wall-n to WH Room 2 UNIT 106>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Wall-n-F 3 UNIT 107 Wall new 90 Front 230 37.5 90
Wall-n-L 2 UNIT 107 Wall new 180 Left 119 14 90
Wall-n-B 3 UNIT 107 Wall new 270 Back 203 64 90
Interior Wall-n to UNIT 108 UNIT 107>>UNIT 108 Wall Int R0 n/a n/a 384 0 n/a
Interior Wall-n to WH Room 3 UNIT 107>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Wall-n-F 4 UNIT 108 Wall new 90 Front 232 33 90
Wall-n-B 4 UNIT 108 Wall new 270 Back 205 64 90
Wall-n-R 2 UNIT 108 Wall new 0 Right 383 34 90
Interior Wall-n to WH Room 4 UNIT 108>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Wall-n-F 5 UNIT 205 Wall new 90 Front 232 47.5 90
Wall-n-L 3 UNIT 205 Wall new 180 Left 383 46 90
Wall-n-B 5 UNIT 205 Wall new 270 Back 205 68 90
Interior Wall-n to UNIT 206 UNIT 205>>UNIT 206 Wall Int R0 n/a n/a 384 0 n/a
Interior Wall-n to WH Room 5 UNIT 205>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Ceiling-n 1 UNIT 205 Ceiling attic new n/a n/a 263 n/a n/a
Ceiling-n 1-2 UNIT 205 Ceiling attic new n/a n/a 668 n/a n/a
Interior Floor-n over UNIT 105 UNIT 205>>UNIT 105 Floor Int R0 n/a n/a 931 n/a n/a
Wall-n-F 6 UNIT 206 Wall new 90 Front 230 47.5 90
Wall-n-B 6 UNIT 206 Wall new 270 Back 203 68 90
Wall-n-R 3 UNIT 206 Wall new 0 Right 119 14 90
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 5 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
Interior Wall-n to UNIT 207 UNIT 206>>UNIT 207 Wall Int R0 n/a n/a 265 0 n/a
Interior Wall-n to WH Room 6 UNIT 206>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Ceiling-n 2 UNIT 206 Ceiling attic new n/a n/a 263 n/a n/a
Ceiling-n 2-2 UNIT 206 Ceiling attic new n/a n/a 668 n/a n/a
Interior Floor-n over UNIT 106 UNIT 206>>UNIT 106 Floor Int R0 n/a n/a 931 n/a n/a
Wall-n-F 7 UNIT 207 Wall new 90 Front 230 47.5 90
Wall-n-L 4 UNIT 207 Wall new 180 Left 119 14 90
Wall-n-B 7 UNIT 207 Wall new 270 Back 203 68 90
Interior Wall-n to UNIT 208 UNIT 207>>UNIT 208 Wall Int R0 n/a n/a 384 0 n/a
Interior Wall-n to WH Room 7 UNIT 207>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Ceiling-n 3 UNIT 207 Ceiling attic new n/a n/a 263 n/a n/a
Ceiling-n 3-2 UNIT 207 Ceiling attic new n/a n/a 668 n/a n/a
Interior Floor-n over UNIT 107 UNIT 207>>UNIT 107 Floor Int R0 n/a n/a 931 n/a n/a
Wall-n-F 8 UNIT 208 Wall new 90 Front 232 47.5 90
Wall-n-B 8 UNIT 208 Wall new 270 Back 205 68 90
Wall-n-R 4 UNIT 208 Wall new 0 Right 383 34 90
Interior Wall-n to WH Room 8 UNIT 208>>WH Rooms Wall Int new n/a n/a 29 0 n/a
Ceiling-n 4 UNIT 208 Ceiling attic new n/a n/a 263 n/a n/a
Ceiling-n 4-2 UNIT 208 Ceiling attic new n/a n/a 668 n/a n/a
Interior Floor-n over UNIT 108 UNIT 208>>UNIT 108 Floor Int R0 n/a n/a 931 n/a n/a
GWall-n-L WH Rooms Wall Gar 180 Left 324 0 90
GWall-n-B WH Rooms Wall Gar 270 Back 245 0 90
GWall-n-R WH Rooms Wall Gar 0 Right 324 0 90
GCeiling-n WH Rooms Ceiling attic Gar n/a n/a 80 n/a n/a
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Tile Tile Roof RB Ventilated 4 0.2 0.85 Yes Yes
Attic-BU Built-Up Roof RB Ventilated 0.25 0.5 0.85 Yes Yes
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 6 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)Width (ft)
Height
(ft)Multiplier
Area
(ft2)U-factor SHGC Exterior Shading
Wind-n-A Window Wall-n-F (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-B Window Wall-n-L (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-W Window Wall-n-L (Left-180)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-V Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-U Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-T Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-S Window Wall-n-B (Back-270)4.0 5.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-R Window Wall-n-B (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-D Window Wall-n-F 2 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-Q Window Wall-n-B 2 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-P Window Wall-n-B 2 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-C Window Wall-n-R (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-E Window Wall-n-F 3 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-F Window Wall-n-L 2 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-O Window Wall-n-B 3 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-N Window Wall-n-B 3 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-H Window Wall-n-F 4 (Front-90)2.0 4.5 1 9.0 0.32 0.25 Insect Screen (default)
Wind-n-M Window Wall-n-B 4 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-L Window Wall-n-B 4 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-I 2 Window Wall-n-R 2 (Right-0)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-G Window Wall-n-R 2 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-Z Window Wall-n-F 5 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default)
Wind-n-X Window Wall-n-F 5 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-Y Window Wall-n-L 3 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-UU Window Wall-n-L 3 (Left-180)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-TT Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-SS Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-RR Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default)
Wind-n-QQ Window Wall-n-B 5 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 7 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
GlDoor-n-67 Window Wall-n-B 5 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default)
Wind-n-CC Window Wall-n-F 6 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-AA Window Wall-n-F 6 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default)
Wind-n-PP Window Wall-n-B 6 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
GlDoor-n-77 Window Wall-n-B 6 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default)
Wind-n-BB Window Wall-n-R 3 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-FF Window Wall-n-F 7 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default)
Wind-n-DD Window Wall-n-F 7 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-EE Window Wall-n-L 4 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
Wind-n-OO Window Wall-n-B 7 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
GlDoor-n-87 Window Wall-n-B 7 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default)
Wind-n-II Window Wall-n-F 8 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default)
Wind-n-GG Window Wall-n-F 8 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default)
Wind-n-NN Window Wall-n-B 8 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
GlDoor-n-97 Window Wall-n-B 8 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default)
Wind-n-JJ Window Wall-n-R 4 (Right-0)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default)
Wind-n-HH Window Wall-n-R 4 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door-n-1 Wall-n-F 24.0 0.50
Door-n-10 Wall-n-B 24.0 0.50
Door-n-11 Wall-n-F 2 24.0 0.50
Door-n-20 Wall-n-B 2 24.0 0.50
Door-n-21 Wall-n-F 3 24.0 0.50
Door-n-30 Wall-n-B 3 24.0 0.50
Door-n-31 Wall-n-F 4 24.0 0.50
Door-n-39 Wall-n-B 4 24.0 0.50
Door-n-58 Wall-n-F 5 24.0 0.50
Door-n-68 Wall-n-F 6 24.0 0.50
Door-n-78 Wall-n-F 7 24.0 0.50
Door-n-88 Wall-n-F 8 24.0 0.50
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 8 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Wind-n-A 6 2 2.7 7 0 0 0 0 0 0 0 0 0
Wind-n-B 13 2 1 2 0 0 0 0 0 0 0 0 0
Wind-n-S 6 2 4 4 0 0 0 0 0 0 0 0 0
Wind-n-D 6 2 7.5 15 0 0 0 0 0 0 0 0 0
Wind-n-P 6 2 1 4 0 0 0 0 0 0 0 0 0
Wind-n-C 25 2 2 1 0 0 0 0 0 0 0 0 0
Wind-n-E 6 2 15 7 0 0 0 0 0 0 0 0 0
Wind-n-F 25 2 1 2 0 0 0 0 0 0 0 0 0
Wind-n-O 6 2 4 1 0 0 0 0 0 0 0 0 0
Wind-n-H 6 2 9 1.8 0 0 0 0 0 0 0 0 0
Wind-n-L 6 2 4 4 0 0 0 0 0 0 0 0 0
Wind-n-G 13 2 2 1 0 0 0 0 0 0 0 0 0
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 9 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
Total Cavity
R-value
Winter Design
U-factor Assembly Layers
Built-Up Roof RB Attic Roofs Wood Framed Ceiling 2x10 @ 24 in. O.C.R 30 0.036
•Cavity / Frame: R-30 / 2x10
•Roof Deck: Wood Siding/sheathing/decking
•Roofing: Light Roof (Asphalt Shingle)
Tile Roof RB Attic Roofs Wood Framed Ceiling 2x10 @ 24 in. O.C.R 30 0.035
•Cavity / Frame: R-30 / 2x10
•Roof Deck: Wood Siding/sheathing/decking
•Tile Gap: present
•Roofing: 10 PSF (RoofTile)
Wall new Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.065
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Sheathing / Insulation: Wood
Siding/sheathing/decking
•Exterior Finish: 3 Coat Stucco
Wall Gar Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.387
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
Wall Int R0 Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.277
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
•Other Side Finish: Gypsum Board
Wall Int new Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.064
•Inside Finish: Gypsum Board
•Cavity / Frame: R-21 / 2x6
•Other Side Finish: Gypsum Board
Floor Int R0 Interior Floors Wood Framed Floor 2x6 @ 16 in. O.C.none 0.199
•Floor Surface: Carpeted
•Floor Deck: Wood Siding/sheathing/decking
•Cavity / Frame: no insul. / 2x6
•Ceiling Below Finish: Gypsum Board
Ceiling attic new
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032
•Inside Finish: Gypsum Board
•Cavity / Frame: R-9.1 / 2x4
•Over Ceiling Joists: R-20.9 insul.
Ceiling attic Gar
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 16 in. O.C.none 0.472
•Inside Finish: Gypsum Board
•Cavity / Frame: no insul. / 2x4
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 10 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated
Slab On Grade-n 1 UNIT 105 931 92 None 0.8 No
Slab On Grade-n 2 UNIT 106 931 62 None 0.8 No
Slab On Grade-n 3 UNIT 107 931 62 None 0.8 No
Slab On Grade-n 4 UNIT 108 931 92 None 0.8 No
GSlab On Grade-n WH Rooms 80 48 None 0 No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type
Number of
Systems
in Building
Multi-Family
Distribution Type Water Heater
Number of
Water
Heaters/System
Solar
Fraction
(%)
DHW System 1 Standard 1 Multi-family: No loops or
recirc pump Water Heater 1 (1)1 n/a
DHW System 2 Standard 1 Multi-family: No loops or
recirc pump Water Heater 2 (1)1 n/a
DHW System 3 Standard 1 Multi-family: No loops or
recirc pump Water Heater 3 (1)1 n/a
DHW System 4 Standard 1 Multi-family: No loops or
recirc pump Water Heater 4 (1)1 n/a
DHW System 5 Standard 1 Multi-family: No loops or
recirc pump Water Heater 5 (1)1 n/a
DHW System 6 Standard 1 Multi-family: No loops or
recirc pump Water Heater 6 (1)1 n/a
DHW System 7 Standard 1 Multi-family: No loops or
recirc pump Water Heater 7 (1)1 n/a
DHW System 8 Standard 1 Multi-family: No loops or
recirc pump Water Heater 8 (1)1 n/a
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 11 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heater
Element
Type Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model
Tank Location
or Ambient
Condition
Water Heater 1 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 2 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 3 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 4 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 5 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 6 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 7 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
Water Heater 8 Electric
Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 12 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
DwellingUnit 105 | :Heat Pump System
1:Distribution System 1:HVAC Fan System 1:2:3
Heat Pump Heating and
Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan System 1 Distribution System 1
DwellingUnit 106 | :Heat Pump System
2:Distribution System 2:HVAC Fan System 2:2:3
Heat Pump Heating and
Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan System 2 Distribution System 2
DwellingUnit 107 | :Heat Pump System
3:Distribution System 3:HVAC Fan System 3:2:3
Heat Pump Heating and
Cooling System Heat Pump System 3 Heat Pump System 3 HVAC Fan System 3 Distribution System 3
DwellingUnit 108 | :Heat Pump System
4:Distribution System 4:HVAC Fan System 4:2:3
Heat Pump Heating and
Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan System 4 Distribution System 4
DwellingUnit 205 | :Heat Pump System
5:Distribution System 5:HVAC Fan System 5:2:3
Heat Pump Heating and
Cooling System Heat Pump System 5 Heat Pump System 5 HVAC Fan System 5 Distribution System 5
DwellingUnit 206 | :Heat Pump System
6:Distribution System 6:HVAC Fan System 6:2:3
Heat Pump Heating and
Cooling System Heat Pump System 6 Heat Pump System 6 HVAC Fan System 6 Distribution System 6
DwellingUnit 207 | :Heat Pump System
7:Distribution System 7:HVAC Fan System 7:2:3
Heat Pump Heating and
Cooling System Heat Pump System 7 Heat Pump System 7 HVAC Fan System 7 Distribution System 7
DwellingUnit 208 | :Heat Pump System
8:Distribution System 8:HVAC Fan System 8:2:3
Heat Pump Heating and
Cooling System Heat Pump System 8 Heat Pump System 8 HVAC Fan System 8 Distribution System 8
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 13 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10
Heating Cooling Zonally Multispeed HERS
Name System Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification
Heat Pump System 1 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
1-hers-cool
Heat Pump System 2 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
2-hers-cool
Heat Pump System 3 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
3-hers-cool
Heat Pump System 4 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
4-hers-cool
Heat Pump System 5 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
5-hers-cool
Heat Pump System 6 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
6-hers-cool
Heat Pump System 7 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
7-hers-cool
Heat Pump System 8 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System
8-hers-cool
HVAC COOLING - HERS VERIFICATION
01 02 03 04 05 06
Name Verified Airflow Airflow Target (CFM)Verified EER Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 2-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 3-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 4-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 5-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 6-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 7-hers-cool Required 350 Not Required Required Not Required
Heat Pump System 8-hers-cool Required 350 Not Required Required Not Required
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 14 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification
Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 6 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 7 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
Distribution System 8 DuctsAttic Sealed and tested 8 Attic None Distribution System
1-hers-dist
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 15 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08
Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage
Name Verification Target (%)Location Design Ducts Ducts Air Handler
Distribution System 1-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 2-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 3-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 4-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 5-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 6-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 7-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
Distribution System 8-hers-dist Required
total leakage <= 12.0
or leakage to
outdoors <= 5.0
Not Required Not Required Not Required Not Required n/a
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 16 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan System 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 7 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC Fan System 8 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan System 1-hers-fan Required 0.58
HVAC Fan System 2-hers-fan Required 0.58
HVAC Fan System 3-hers-fan Required 0.58
HVAC Fan System 4-hers-fan Required 0.58
HVAC Fan System 5-hers-fan Required 0.58
HVAC Fan System 6-hers-fan Required 0.58
HVAC Fan System 7-hers-fan Required 0.58
HVAC Fan System 8-hers-fan Required 0.58
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 17 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
IAQ (Indoor Air Quality) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
DwellingUnit 105 1/1 50 0.25 Default 0 Required
DwellingUnit 106 1/1 50 0.25 Default 0 Required
DwellingUnit 107 1/1 50 0.25 Default 0 Required
DwellingUnit 108 1/1 50 0.25 Default 0 Required
DwellingUnit 205 1/1 50 0.25 Default 0 Required
DwellingUnit 206 1/1 50 0.25 Default 0 Required
DwellingUnit 207 1/1 50 0.25 Default 0 Required
DwellingUnit 208 1/1 50 0.25 Default 0 Required
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 18 of 18
Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16
Registration Number:Registration Date/Time:HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Igor Pichko
Energy Consult LLC
1252 w 22nd st #2
San Pedro, CA 90731
2022-04-06 17:20:17
R19-14-30005
424-247-7658
Stephen Nieto
South West Concepts
78-115 Calle Estado
La Quinta, CA 92253
2022-04-07 11:09:53
Stephen Nieto
760-564-4704
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.