Loading...
BRES2019-0330 Title 24CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 1 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    GENERAL INFORMATION 01 Project Name An Apartment Complex for Nispero Properties, Inc 02 Calculation Description Title 24 Analysis 03 Project Location 51-480 Desert Club Dr / North bldg   04 City La Quinta, CA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.3.1 (1019) 10 Building Type Multifamily 11 Front Orientation (deg/Cardinal)90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 8 14 Total Cond. Floor Area (ft2)7448 15 Number of Zones 8 16 Slab Area (ft2)3724 17 Number of Stories 2 18 Addition Cond. Floor Area(ft2)n/a 19 Natural Gas Available No 20 Addition Slab Area (ft2)n/a 21 Glazing Percentage (%)10.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below . ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.57 0.54 0.03 5.3% Space Cooling 88.06 75.50 12.56 14.3% IAQ Ventilation 2.49 2.49 0.00 0.0% Water Heating 22.75 33.75 -11.00 -48.4% Photovoltaic Offset ----0.00 0.00 ---- Compliance Energy Total 113.87 112.28 1.59 1.4% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.  •Cool roof •Window overhangs and/or fins 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. BRES2019-0330 – NORTH BUILDING / 51480 DESERT CLUB DR 8,319SF MULTI-FAMILY 8-UNIT APARTMENT BUILDING WITH 1,855SF GARAGE [VB/R-2 + S-1 OCC/40-OL/ CLASS A-FR/13R SPRINKLER SYSTEM] THIS PERMIT DOES NOT INCLUDE SITE LIGHTING, TRASH ENCLOSURE, CARPORTS OR SIGNAGE. 2016 CALIFORNIA BUILDING CODES. 9/6/2022 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 2 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis.  Additional detail is provided in the building components tables below. Building-level Verifications: •High quality insulation installation (QII) •IAQ mechanical ventilation Cooling System Verifications: •-- None -- HVAC Distribution System Verifications: •Duct Sealing Domestic Hot Water System Verifications: •-- None -- ZONE INFORMATION 01 02 03 04 05 Zone Name Zone Type Zone Floor Area (ft2)Avg. Ceiling Height Number of Dwelling Units UNIT 105 Conditioned 931 9 1 UNIT 106 Conditioned 931 9 1 UNIT 107 Conditioned 931 9 1 UNIT 108 Conditioned 931 9 1 UNIT 205 Conditioned 931 9 1 UNIT 206 Conditioned 931 9 1 UNIT 207 Conditioned 931 9 1 UNIT 208 Conditioned 931 9 1 DWELLING UNIT INFORMATION 01 02 03 Dwelling Unit Name Dwelling Unit Type Zone DwellingUnit 105-(1/1)U-105 UNIT 105 DwellingUnit 106-(1/1)U-106 UNIT 106 DwellingUnit 107-(1/1)U-107 UNIT 107 DwellingUnit 108-(1/1)U-108 UNIT 108 DwellingUnit 205-(1/1)U-205 UNIT 205 DwellingUnit 206-(1/1)U-206 UNIT 206 DwellingUnit 207-(1/1)U-207 UNIT 207 DwellingUnit 208-(1/1)U-208 UNIT 208 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 3 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    DWELLING UNIT TYPES 01 02 03 04 05 06 07 Name CFA (ft2) Number of Bedrooms Number in Building Space Conditioning Systems Assigned DHW System Name IAQ Vent Fan Name U-105 931 2 1 DwellingUnit 105 | :Heat Pump System 1:Distribution System 1:HVAC Fan System 1:2:3 DHW System 1 Default Minimum IAQ Fan U-106 931 2 1 DwellingUnit 106 | :Heat Pump System 2:Distribution System 2:HVAC Fan System 2:2:3 DHW System 2 Default Minimum IAQ Fan U-107 931 2 1 DwellingUnit 107 | :Heat Pump System 3:Distribution System 3:HVAC Fan System 3:2:3 DHW System 3 Default Minimum IAQ Fan U-108 931 2 1 DwellingUnit 108 | :Heat Pump System 4:Distribution System 4:HVAC Fan System 4:2:3 DHW System 4 Default Minimum IAQ Fan U-205 931 2 1 DwellingUnit 205 | :Heat Pump System 5:Distribution System 5:HVAC Fan System 5:2:3 DHW System 5 Default Minimum IAQ Fan U-206 931 2 1 DwellingUnit 206 | :Heat Pump System 6:Distribution System 6:HVAC Fan System 6:2:3 DHW System 6 Default Minimum IAQ Fan U-207 931 2 1 DwellingUnit 207 | :Heat Pump System 7:Distribution System 7:HVAC Fan System 7:2:3 DHW System 7 Default Minimum IAQ Fan U-208 931 2 1 DwellingUnit 208 | :Heat Pump System 8:Distribution System 8:HVAC Fan System 8:2:3 DHW System 8 Default Minimum IAQ Fan 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 4 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg) Wall-n-F UNIT 105 Wall new 90 Front 232 37.5 90 Wall-n-L UNIT 105 Wall new 180 Left 383 46 90 Wall-n-B UNIT 105 Wall new 270 Back 205 64 90 Interior Wall-n to UNIT 106 UNIT 105>>UNIT 106 Wall Int R0 n/a n/a 384 0 n/a Interior Wall-n to WH Room 1 UNIT 105>>WH Rooms Wall Int new n/a n/a 29 0 n/a Wall-n-F 2 UNIT 106 Wall new 90 Front 230 37.5 90 Wall-n-B 2 UNIT 106 Wall new 270 Back 203 64 90 Wall-n-R UNIT 106 Wall new 0 Right 119 14 90 Interior Wall-n to UNIT 107 UNIT 106>>UNIT 107 Wall Int R0 n/a n/a 265 0 n/a Interior Wall-n to WH Room 2 UNIT 106>>WH Rooms Wall Int new n/a n/a 29 0 n/a Wall-n-F 3 UNIT 107 Wall new 90 Front 230 37.5 90 Wall-n-L 2 UNIT 107 Wall new 180 Left 119 14 90 Wall-n-B 3 UNIT 107 Wall new 270 Back 203 64 90 Interior Wall-n to UNIT 108 UNIT 107>>UNIT 108 Wall Int R0 n/a n/a 384 0 n/a Interior Wall-n to WH Room 3 UNIT 107>>WH Rooms Wall Int new n/a n/a 29 0 n/a Wall-n-F 4 UNIT 108 Wall new 90 Front 232 33 90 Wall-n-B 4 UNIT 108 Wall new 270 Back 205 64 90 Wall-n-R 2 UNIT 108 Wall new 0 Right 383 34 90 Interior Wall-n to WH Room 4 UNIT 108>>WH Rooms Wall Int new n/a n/a 29 0 n/a Wall-n-F 5 UNIT 205 Wall new 90 Front 232 47.5 90 Wall-n-L 3 UNIT 205 Wall new 180 Left 383 46 90 Wall-n-B 5 UNIT 205 Wall new 270 Back 205 68 90 Interior Wall-n to UNIT 206 UNIT 205>>UNIT 206 Wall Int R0 n/a n/a 384 0 n/a Interior Wall-n to WH Room 5 UNIT 205>>WH Rooms Wall Int new n/a n/a 29 0 n/a Ceiling-n 1 UNIT 205 Ceiling attic new n/a n/a 263 n/a n/a Ceiling-n 1-2 UNIT 205 Ceiling attic new n/a n/a 668 n/a n/a Interior Floor-n over UNIT 105 UNIT 205>>UNIT 105 Floor Int R0 n/a n/a 931 n/a n/a Wall-n-F 6 UNIT 206 Wall new 90 Front 230 47.5 90 Wall-n-B 6 UNIT 206 Wall new 270 Back 203 68 90 Wall-n-R 3 UNIT 206 Wall new 0 Right 119 14 90 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 5 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    Interior Wall-n to UNIT 207 UNIT 206>>UNIT 207 Wall Int R0 n/a n/a 265 0 n/a Interior Wall-n to WH Room 6 UNIT 206>>WH Rooms Wall Int new n/a n/a 29 0 n/a Ceiling-n 2 UNIT 206 Ceiling attic new n/a n/a 263 n/a n/a Ceiling-n 2-2 UNIT 206 Ceiling attic new n/a n/a 668 n/a n/a Interior Floor-n over UNIT 106 UNIT 206>>UNIT 106 Floor Int R0 n/a n/a 931 n/a n/a Wall-n-F 7 UNIT 207 Wall new 90 Front 230 47.5 90 Wall-n-L 4 UNIT 207 Wall new 180 Left 119 14 90 Wall-n-B 7 UNIT 207 Wall new 270 Back 203 68 90 Interior Wall-n to UNIT 208 UNIT 207>>UNIT 208 Wall Int R0 n/a n/a 384 0 n/a Interior Wall-n to WH Room 7 UNIT 207>>WH Rooms Wall Int new n/a n/a 29 0 n/a Ceiling-n 3 UNIT 207 Ceiling attic new n/a n/a 263 n/a n/a Ceiling-n 3-2 UNIT 207 Ceiling attic new n/a n/a 668 n/a n/a Interior Floor-n over UNIT 107 UNIT 207>>UNIT 107 Floor Int R0 n/a n/a 931 n/a n/a Wall-n-F 8 UNIT 208 Wall new 90 Front 232 47.5 90 Wall-n-B 8 UNIT 208 Wall new 270 Back 205 68 90 Wall-n-R 4 UNIT 208 Wall new 0 Right 383 34 90 Interior Wall-n to WH Room 8 UNIT 208>>WH Rooms Wall Int new n/a n/a 29 0 n/a Ceiling-n 4 UNIT 208 Ceiling attic new n/a n/a 263 n/a n/a Ceiling-n 4-2 UNIT 208 Ceiling attic new n/a n/a 668 n/a n/a Interior Floor-n over UNIT 108 UNIT 208>>UNIT 108 Floor Int R0 n/a n/a 931 n/a n/a GWall-n-L WH Rooms Wall Gar 180 Left 324 0 90 GWall-n-B WH Rooms Wall Gar 270 Back 245 0 90 GWall-n-R WH Rooms Wall Gar 0 Right 324 0 90 GCeiling-n WH Rooms Ceiling attic Gar n/a n/a 80 n/a n/a     ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Tile Tile Roof RB Ventilated 4 0.2 0.85 Yes Yes Attic-BU Built-Up Roof RB Ventilated 0.25 0.5 0.85 Yes Yes   219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 6 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation-Azimuth)Width (ft) Height (ft)Multiplier Area (ft2)U-factor SHGC Exterior Shading Wind-n-A Window Wall-n-F (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-B Window Wall-n-L (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-W Window Wall-n-L (Left-180)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-V Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-U Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-T Window Wall-n-L (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-S Window Wall-n-B (Back-270)4.0 5.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-R Window Wall-n-B (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-D Window Wall-n-F 2 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-Q Window Wall-n-B 2 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-P Window Wall-n-B 2 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-C Window Wall-n-R (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-E Window Wall-n-F 3 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-F Window Wall-n-L 2 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-O Window Wall-n-B 3 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-N Window Wall-n-B 3 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-H Window Wall-n-F 4 (Front-90)2.0 4.5 1 9.0 0.32 0.25 Insect Screen (default) Wind-n-M Window Wall-n-B 4 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-L Window Wall-n-B 4 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-I 2 Window Wall-n-R 2 (Right-0)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-G Window Wall-n-R 2 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-Z Window Wall-n-F 5 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default) Wind-n-X Window Wall-n-F 5 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-Y Window Wall-n-L 3 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-UU Window Wall-n-L 3 (Left-180)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-TT Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-SS Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-RR Window Wall-n-L 3 (Left-180)2.0 2.0 1 4.0 0.32 0.25 Insect Screen (default) Wind-n-QQ Window Wall-n-B 5 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 7 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    GlDoor-n-67 Window Wall-n-B 5 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) Wind-n-CC Window Wall-n-F 6 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-AA Window Wall-n-F 6 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default) Wind-n-PP Window Wall-n-B 6 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) GlDoor-n-77 Window Wall-n-B 6 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) Wind-n-BB Window Wall-n-R 3 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-FF Window Wall-n-F 7 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default) Wind-n-DD Window Wall-n-F 7 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-EE Window Wall-n-L 4 (Left-180)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) Wind-n-OO Window Wall-n-B 7 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) GlDoor-n-87 Window Wall-n-B 7 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) Wind-n-II Window Wall-n-F 8 (Front-90)3.0 4.5 1 13.5 0.32 0.25 Insect Screen (default) Wind-n-GG Window Wall-n-F 8 (Front-90)5.0 2.0 1 10.0 0.32 0.25 Insect Screen (default) Wind-n-NN Window Wall-n-B 8 (Back-270)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) GlDoor-n-97 Window Wall-n-B 8 (Back-270)6.0 8.0 1 48.0 0.32 0.25 Insect Screen (default) Wind-n-JJ Window Wall-n-R 4 (Right-0)5.0 4.0 1 20.0 0.32 0.25 Insect Screen (default) Wind-n-HH Window Wall-n-R 4 (Right-0)3.5 4.0 1 14.0 0.32 0.25 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Door-n-1 Wall-n-F 24.0 0.50 Door-n-10 Wall-n-B 24.0 0.50 Door-n-11 Wall-n-F 2 24.0 0.50 Door-n-20 Wall-n-B 2 24.0 0.50 Door-n-21 Wall-n-F 3 24.0 0.50 Door-n-30 Wall-n-B 3 24.0 0.50 Door-n-31 Wall-n-F 4 24.0 0.50 Door-n-39 Wall-n-B 4 24.0 0.50 Door-n-58 Wall-n-F 5 24.0 0.50 Door-n-68 Wall-n-F 6 24.0 0.50 Door-n-78 Wall-n-F 7 24.0 0.50 Door-n-88 Wall-n-F 8 24.0 0.50 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 8 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14  Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Wind-n-A 6 2 2.7 7 0 0 0 0 0 0 0  0 0 Wind-n-B 13 2 1 2 0 0 0 0 0 0 0  0 0 Wind-n-S 6 2 4 4 0 0 0 0 0 0 0  0 0 Wind-n-D 6 2 7.5 15 0 0 0 0 0 0 0  0 0 Wind-n-P 6 2 1 4 0 0 0 0 0 0 0  0 0 Wind-n-C 25 2 2 1 0 0 0 0 0 0 0  0 0 Wind-n-E 6 2 15 7 0 0 0 0 0 0 0  0 0 Wind-n-F 25 2 1 2 0 0 0 0 0 0 0  0 0 Wind-n-O 6 2 4 1 0 0 0 0 0 0 0  0 0 Wind-n-H 6 2 9 1.8 0 0 0 0 0 0 0  0 0 Wind-n-L 6 2 4 4 0 0 0 0 0 0 0  0 0 Wind-n-G 13 2 2 1 0 0 0 0 0 0 0  0 0 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 9 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Built-Up Roof RB Attic Roofs Wood Framed Ceiling 2x10 @ 24 in. O.C.R 30 0.036 •Cavity / Frame: R-30 / 2x10 •Roof Deck: Wood Siding/sheathing/decking •Roofing: Light Roof (Asphalt Shingle) Tile Roof RB Attic Roofs Wood Framed Ceiling 2x10 @ 24 in. O.C.R 30 0.035 •Cavity / Frame: R-30 / 2x10 •Roof Deck: Wood Siding/sheathing/decking •Tile Gap: present •Roofing: 10 PSF (RoofTile) Wall new Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.065 •Inside Finish: Gypsum Board •Cavity / Frame: R-21 / 2x6 •Sheathing / Insulation: Wood Siding/sheathing/decking •Exterior Finish: 3 Coat Stucco Wall Gar Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.387 •Inside Finish: Gypsum Board •Cavity / Frame: no insul. / 2x4 Wall Int R0 Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C.none 0.277 •Inside Finish: Gypsum Board •Cavity / Frame: no insul. / 2x4 •Other Side Finish: Gypsum Board Wall Int new Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C.R 21 0.064 •Inside Finish: Gypsum Board •Cavity / Frame: R-21 / 2x6 •Other Side Finish: Gypsum Board Floor Int R0 Interior Floors Wood Framed Floor 2x6 @ 16 in. O.C.none 0.199 •Floor Surface: Carpeted •Floor Deck: Wood Siding/sheathing/decking •Cavity / Frame: no insul. / 2x6 •Ceiling Below Finish: Gypsum Board Ceiling attic new Ceilings (below attic)Wood Framed Ceiling 2x4 @ 24 in. O.C.R 30 0.032 •Inside Finish: Gypsum Board •Cavity / Frame: R-9.1 / 2x4 •Over Ceiling Joists: R-20.9 insul. Ceiling attic Gar Ceilings (below attic)Wood Framed Ceiling 2x4 @ 16 in. O.C.none 0.472 •Inside Finish: Gypsum Board •Cavity / Frame: no insul. / 2x4 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 10 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value & Depth Carpeted Fraction Heated Slab On Grade-n 1 UNIT 105 931 92 None 0.8 No Slab On Grade-n 2 UNIT 106 931 62 None 0.8 No Slab On Grade-n 3 UNIT 107 931 62 None 0.8 No Slab On Grade-n 4 UNIT 108 931 92 None 0.8 No GSlab On Grade-n WH Rooms 80 48 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Number of Systems in Building Multi-Family  Distribution Type Water Heater Number of Water Heaters/System Solar Fraction (%) DHW System 1 Standard 1 Multi-family: No loops or recirc pump Water Heater 1 (1)1 n/a DHW System 2 Standard 1 Multi-family: No loops or recirc pump Water Heater 2 (1)1 n/a DHW System 3 Standard 1 Multi-family: No loops or recirc pump Water Heater 3 (1)1 n/a DHW System 4 Standard 1 Multi-family: No loops or recirc pump Water Heater 4 (1)1 n/a DHW System 5 Standard 1 Multi-family: No loops or recirc pump Water Heater 5 (1)1 n/a DHW System 6 Standard 1 Multi-family: No loops or recirc pump Water Heater 6 (1)1 n/a DHW System 7 Standard 1 Multi-family: No loops or recirc pump Water Heater 7 (1)1 n/a DHW System 8 Standard 1 Multi-family: No loops or recirc pump Water Heater 8 (1)1 n/a 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 11 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition Water Heater 1 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 2 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 3 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 4 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 5 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 6 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 7 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms Water Heater 8 Electric Resistance Small Storage 1 50 0.945 EF <= 12 kW 0 n/a n/a n/a WH Rooms 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 12 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name DwellingUnit 105 | :Heat Pump System 1:Distribution System 1:HVAC Fan System 1:2:3 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan System 1 Distribution System 1 DwellingUnit 106 | :Heat Pump System 2:Distribution System 2:HVAC Fan System 2:2:3 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 HVAC Fan System 2 Distribution System 2 DwellingUnit 107 | :Heat Pump System 3:Distribution System 3:HVAC Fan System 3:2:3 Heat Pump Heating and Cooling System Heat Pump System 3 Heat Pump System 3 HVAC Fan System 3 Distribution System 3 DwellingUnit 108 | :Heat Pump System 4:Distribution System 4:HVAC Fan System 4:2:3 Heat Pump Heating and Cooling System Heat Pump System 4 Heat Pump System 4 HVAC Fan System 4 Distribution System 4 DwellingUnit 205 | :Heat Pump System 5:Distribution System 5:HVAC Fan System 5:2:3 Heat Pump Heating and Cooling System Heat Pump System 5 Heat Pump System 5 HVAC Fan System 5 Distribution System 5 DwellingUnit 206 | :Heat Pump System 6:Distribution System 6:HVAC Fan System 6:2:3 Heat Pump Heating and Cooling System Heat Pump System 6 Heat Pump System 6 HVAC Fan System 6 Distribution System 6 DwellingUnit 207 | :Heat Pump System 7:Distribution System 7:HVAC Fan System 7:2:3 Heat Pump Heating and Cooling System Heat Pump System 7 Heat Pump System 7 HVAC Fan System 7 Distribution System 7 DwellingUnit 208 | :Heat Pump System 8:Distribution System 8:HVAC Fan System 8:2:3 Heat Pump Heating and Cooling System Heat Pump System 8 Heat Pump System 8 HVAC Fan System 8 Distribution System 8 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 13 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10   Heating Cooling Zonally Multispeed HERS Name System Type HSPF/COP Cap 47 Cap 17 SEER EER Controlled Compressor Verification Heat Pump System 1 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 1-hers-cool Heat Pump System 2 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 2-hers-cool Heat Pump System 3 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 3-hers-cool Heat Pump System 4 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 4-hers-cool Heat Pump System 5 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 5-hers-cool Heat Pump System 6 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 6-hers-cool Heat Pump System 7 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 7-hers-cool Heat Pump System 8 PkgHeatPump 8.2 36000 29000 15 12.44 No No Heat Pump System 8-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target (CFM)Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Not Required Required Not Required Heat Pump System 2-hers-cool Required 350 Not Required Required Not Required Heat Pump System 3-hers-cool Required 350 Not Required Required Not Required Heat Pump System 4-hers-cool Required 350 Not Required Required Not Required Heat Pump System 5-hers-cool Required 350 Not Required Required Not Required Heat Pump System 6-hers-cool Required 350 Not Required Required Not Required Heat Pump System 7-hers-cool Required 350 Not Required Required Not Required Heat Pump System 8-hers-cool Required 350 Not Required Required Not Required 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 14 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    HVAC -  DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 6 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 7 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist Distribution System 8 DuctsAttic Sealed and tested 8 Attic None Distribution System 1-hers-dist 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 15 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08  Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Deeply Buried Low-leakage Name  Verification Target (%)Location Design Ducts Ducts Air Handler Distribution System 1-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 2-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 3-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 4-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 5-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 6-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 7-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a Distribution System 8-hers-dist Required total leakage <= 12.0 or leakage to outdoors <= 5.0 Not Required Not Required Not Required Not Required n/a 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 16 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    HVAC - FAN  SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)HERS Verification HVAC Fan System 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 7 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC Fan System 8 Single Speed PSC Furnace Fan 0.58 HVAC Fan System 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan System 1-hers-fan Required 0.58 HVAC Fan System 2-hers-fan Required 0.58 HVAC Fan System 3-hers-fan Required 0.58 HVAC Fan System 4-hers-fan Required 0.58 HVAC Fan System 5-hers-fan Required 0.58 HVAC Fan System 6-hers-fan Required 0.58 HVAC Fan System 7-hers-fan Required 0.58 HVAC Fan System 8-hers-fan Required 0.58 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 17 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%)HERS Verification DwellingUnit 105 1/1 50 0.25 Default 0 Required DwellingUnit 106 1/1 50 0.25 Default 0 Required DwellingUnit 107 1/1 50 0.25 Default 0 Required DwellingUnit 108 1/1 50 0.25 Default 0 Required DwellingUnit 205 1/1 50 0.25 Default 0 Required DwellingUnit 206 1/1 50 0.25 Default 0 Required DwellingUnit 207 1/1 50 0.25 Default 0 Required DwellingUnit 208 1/1 50 0.25 Default 0 Required   219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name:An Apartment Complex for Nispero Properties, Inc Calculation Date/Time:16:43, Wed, Apr 06, 2022 Page 18 of 18 Calculation Description:Title 24 Analysis Input File Name:51-480_Desert_Club_MF-N_r1.ribd16 Registration Number:Registration Date/Time:HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2022-04-06 16:45:10    DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: Easy to Verify at CalCERTS.com Igor Pichko Energy Consult LLC 1252 w 22nd st #2 San Pedro, CA 90731 2022-04-06 17:20:17 R19-14-30005 424-247-7658 Stephen Nieto South West Concepts 78-115 Calle Estado La Quinta, CA 92253 2022-04-07 11:09:53 Stephen Nieto 760-564-4704 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 219-P010216099B-000-000-0000000-0000 2022-04-07 11:09:53 CalCERTS inc.