FA2024-0003BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 05/01/2024 ISSUED DATE: Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Fire Alarm/Monitoring System 51480 DESERT CLUB DR FA2024-0003 770181010 L SEE MAP H-P MB 19/75 DESERT CLUB TR UNIT $471,154.10 VC, SEE MAP H-P Owner: Applicant:Jovannah Gonzalez 75130 St Charles Place, Palm Desert, CA 92211 Contractor:Jovannah Gonzalez / 1084934 75130 St Charles Place, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/18/25 9:43 am Page 1 of 3 Permit Type: Permit Number: Property Address: Fire Alarm/Monitoring System FA2024-0003 51480 DESERT CLUB DR BUILDING PERMIT Fire Alarm Monitoring System Plans / 51480 Desert Club Dr Use of Permit Construction Details R-2: Multi-FamilyBuilding/Unit Occupancy Classification(s) 32Calculated Occupancy Load Fire Protection Service Corporation dba Pye Barker Fire Alarm System - Monitoring Company Name 75130 St Charles Place, Palm Desert, CA 92211 Monitoring Company Address (760)341-3593Monitoring Company Phone Number Central Supervising StationSupervising Station Type UL CERTIFICATE # (if applicable): VCZoning VCGeneral Plan Within La Quinta LimitsCity Limits DESERT CLUB TR UNITSubdivision Name SEE MAP H-PLot Number 4419.53Lot Size 96673, 98224, 17232Centerlines L SEE MAP H-P MB 19/75 DESERT CLUB TR UNIT Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00007107 $8.00 Technology Enhancement Fee $8.00 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $11.95 Credit Card Convenience Fee $11.95 $458.00 Fire - Alarm-Monitoring and Tenant Improvements $458.00 $489.95 $489.95 Total for Invoice INV-00007107 NOT INVOICED $0.00 Fire - Failed or Additional Field Inspections $191.00 $191.00 $0.00 Total for Invoice NOT INVOICED Grand Total for Permit $680.95 $489.95 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 08/30/2024 0:00 10/04/2024 19:13 Fire Alarm Rough Wire v.1 Inspection 08/30/2024 0:00 09/04/2024 12:09 Fire Alarm Rough Wire v.2 Inspection 10/02/2024 0:00 10/02/2024 8:18 Fire Alarm Monitoring - Function v.1 Inspection 10/02/2024 7:28 10/04/2024 19:12 Fire Alarm Final v.1 Inspection 10/02/2024 7:28 10/04/2024 19:13 Linked Records v.1 05/01/2024 17:25 03/04/2025 14:58 Linked Permits v.1 Create Sub Permit 05/01/2024 17:25 03/04/2025 14:58 Linked Permits v.1 Create Sub Permit 05/01/2024 17:25 12/09/2024 13:34 Linked Permits v.1 Create Sub Permit 05/02/2024 8:29 12/18/2024 17:07 Review v.1 05/02/2024 0:00 06/05/2024 16:45 Fire Review v.1 Receive Submittal 05/02/2024 0:00 05/10/2024 13:02 Fire Review v.2 Receive Submittal 05/28/2024 0:00 06/05/2024 16:45 Inspections v.1 08/07/2025 12:12 08/07/2025 12:50 Fire Alarm Rough Wire v.1 Inspection 08/07/2025 12:11 Fire Alarm Monitoring - Function v.1 Inspection 08/07/2025 12:12 08/07/2025 12:20 Printed: 9/18/25 9:43 am Page 2 of 3 Permit Type: Permit Number: Property Address: Fire Alarm/Monitoring System FA2024-0003 51480 DESERT CLUB DR BUILDING PERMIT Fire Alarm Monitoring - Function v.2 Inspection 08/07/2025 0:00 08/07/2025 12:50 Fire Alarm Final v.1 Inspection 08/07/2025 12:12 08/07/2025 12:21 Fire Alarm Final v.2 Inspection 08/07/2025 0:00 08/07/2025 12:50 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 9/18/25 9:43 am Page 3 of 3 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org May 10, 2024 Jeffrey Mansfield Re: Fire Alarm – Desert Club Apartments FA2024-0003 / 51480 Desert Club Drive The plan needs to be corrected: 1) On the plan, provide the State license number for Pye Barker and remove the license number for Comtron. 2) Provide the manufacture data sheet and the State Fire Marshal listing sheet for the communicator. 3) Remove the manual pull station. It’s not required. Reference California Fire Code 907.2 4) Fire alarm occupant notification is not required for this building. Two notification appliances are shown inside one of the apartments. Partial occupant notification should not be provided. If occupant notification is desired by the owner, then occupant notification shall be provided throughout the building in accordance with CFC 907.5 and a statement shall be provided on the plans that the owner has voluntarily chosen to provide occupant notification although occupant notification is not required for this building by the California Fire Code. CFC 907.2.9.1 5) An automatic smoke detection system is not required for this building inside of the apartments if single and multiple station smoke alarms are provided. One of the apartments shows a smoke detector in one of the bedrooms. Explain the intention of this device. According to the floor plan, the apartment unit with the smoke detector appears to be unit 107, but the enlarged riser room plan references unit 203 for the location of this smoke detector. Reference CFC 907.2.11 All questions regarding the meaning of these requirements should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox – Supervising Fire Marshal OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org June 5, 2024 Pye Barker Re: Fire Alarm – Desert Club Apartments FA2024-0003 / 51480 Desert Club Drive The plan for the above referenced project was reviewed and approved by the Riverside County Fire Department with the following conditions: 1. The Office of the Fire Marshal staff shall witness the function test. 2. Provide a completed NFPA 72 Record of Completion that the system has been installed in accordance with the approved plans and specifications as required. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance by sending an email to FireBusinessMail@laquintaca.gov. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox – Supervising Fire Marshal 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 51480 Desert Club Drive PERMIT#: FA2024-0003 DATE ISSUED: 6/5/24 DESCRIPTION: Fire Alarm CONTRACTOR: Pye Barker HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections email: FireBusinessMail@laquintaca.gov B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. INSTALLATION NOTES GENERAL NOTES CENTRAL STATION INSTALL NEW 12 VOLT FIRE PANEL WITH DEVICES AS INDICATED ON PLANS FOR A NEW FIRE SPRINKLER MONITORING SYSTEM IN DESERT CLUB APARTMENTS AT 51480 DESERT CLUB DRIVE, LA QUINTA, CA 92253. CORRECTIONS NOTES: REMOVE SMOKE DETECTOR AND NOTIFICATION APPLIANCES IN UNIT 107, SEE FA-2. REMOVE MANUAL PULL STATION, SEE ENLARGED DETAIL. BATTERY CALCULATION UPDATED ACCORDINGLY. VOLTAGE DROP REMOVE, NOTIFICATION APPLIANCES REMOVE, NOT REQUIRED PER C.F.C. 907.2.9.1 CONTRACTOR LICENSE UPDATED, SEE TITLE BLOCK FA-1 & FA-2. SHEET DESCRIPTION FA-1 SEQUENCE OF OPERATION, EQUIP. LEGEND, GENERAL NOTES, AND BATTERY CALCULATIONS. FA-2 FIRE SPRINKLER MONITORING SYSTEM PLAN, RISER DIAGRAM, AND WIRING DETAILS. SCOPE OF WORK SHEET INDEX A.THE ADDRESSABLE FIRE CONTROL PANEL/DACT IS INHERENTLY POWER LIMITED; SIGNALING AND INITIATING CIRCUITS DO NOT REQUIRE OVERCURRENT PROTECTION. B.THE ADDRESSABLE FIRE CONTROL PANEL/DACT WILL BE PROGRAMMED TO INITIATE AND COMPLETE A TEST SIGNAL TRANSMISSION EVERY 24 HOURS. C.CONSULT WITH OWNER AND/OR GENERAL CONTRACTOR FOR EXACT LOCATION OF THE FIRE CONTROL PANEL/TRANSPONDER PRIOR TO INSTALLATION. D.INSTALLER SHALL COORDINATE ALL WORK WITH THE OWNER AND GENERAL CONTRACTOR AND ALL OTHER TRADES. E.THE EQUIPMENT AND MATERIAL USED ARE STATE FIRE MARSHAL LISTED AND APPROVED FOR TRANSMISSION OF SIGNALS AS SET FORTH BY NFPA 72 STANDARDS FOR SEIZURE CAPABILITIES. F.FIRE ALARM RECORD OF COMPLETION TO BE PROVIDED TO FIRE DEPARTMENT AT FINAL. G.AN ORIGINAL APPROVED PLAN SET SHALL BE ON SITE DURING ANY FIRE DEPARTMENT INSPECTION. H.ADDENDUM PLANS SHALL BE SUBMITTED AND APPROVED BEFORE THE FIRE ALARM PERMIT WILL BE FINALED, IF ANY CHANGES TO THIS FIRE ALARM PLANS ARE MADE. I.ALL MANUFACTURER DATA SHEETS WILL BE SUPPLIED WITH SUBMITTAL PLANS. J.HORN STROBES SHALL NOT BE SILENCED ON A WATER FLOW ZONE K.A COMPLETE COPY OF THE APPROVED PLAN SET SHALL BE ON SITE DURING ANY FIRE DEPT INSPECTION. VICINITY MAP N.T.S. OCCUPANCY TYPE: A.P.N.: FIRE SPRINKLER: TOTAL SQ. FOOTAGE: YES 9,183 "R-2" 770-181-010 SITE INFORMATION THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 NFPA 72 CODE CRITERIA 1.ALL CIRCUITS WILL BE IDENTIFIED AT JUNCTIONS AND AT TERMINATIONS BY MEANS OF A DURABLE AND VISIBLE LABEL. [CEC 760.10] 2.NO "T" TAPPING OF FIELD WIRING IS PERMISSIBLE IN SUPERVISED CIRCUITS; DATA CIRCUITS ARE EXCLUDED. 3.MOUNTING OF ALL DEVICES SHALL COMPLY WITH NFPA 72, INCLUDING CALIFORNIA AMENDMENTS. 4.IF THE TRANSMITTER IS NOT LOCATED IN THE SAME ROOM AS THE TELCO EQUIPMENT BACKBOARD, FIRE WIRE IS TO BE USED BETWEEN THE "D" MARK AND THE FIRE ALARM CONTROL PANEL. EXCEPTION; IF CONDUIT IS PROVIDED FROM TELCO BACKBOARD TO TRANSMITTER LOCATION, STANDARD I/O WIRE MAY BE USED. 5.INSTALLATION WILL COMPLY WITH SECTION 300.21 OF CALIFORNIA ELECTRICAL CODE REGARDING PENETRATIONS THROUGH FIRE RESISTIVE ASSEMBLIES TO PREVENT THE SPREAD OF FIRE AND TOXIC PRODUCTS OF COMBUSTION. 6.SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL DUST PRODUCING AND SPRAYING TRADES HAS BEEN COMPLETED. 7.WHERE BUILDING CONTROL CIRCUITS ( E.G. ELEVATOR CAPTURE, SMOKE/FIRE DAMPERS, FAN SHUTOFF) ARE ASSOCIATED WITH THE FIRE ALARM SYSTEM, THE INSTALLATION SHALL COMPLY WITH CEC, ARTICLE 725. [CEC 760.3] 8.ALL WIRING SHALL NOT BE LOOPED THROUGH DEVICES. WIRE MUST BE CUT FOR IN AND OUT. 9.ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO THE MANUFACTURER'S SPECIFICATIONS. 10.AREAS HAVING MORE THAN 2 STROBES IN THE FIELD OF VIEW SHALL BE SYNCHRONIZED. 11.FIRE ALARM SIGNAL SHALL MEET ANSI S3.41, AUDIBLE EMERGENCY EVACUATION SIGNAL (TEMPORAL PATTERN). 12.ALL EXTERIOR ELECTRICAL JUNCTION BOXES, OUTSIDE CONTROL VALVES, AND FLOW SWITCHES SHALL HAVE ELECTRICALLY SUPERVISED COVERS. TAMPER PROOF SCREWS MAY BE USED IN LIEU OF ELECTRICAL SUPERVISION, PER 2022 EDITION NFPA 72. TAMPER PROOF SCREWS SHALL BE USED UNLESS NOTED OTHERWISE. 13.FIRE ALARM LOCKED PANEL SHALL BE ACCESSIBLE ONLY TO FIRE DEPT. PERSONNEL, AUTHORIZED MAINTENANCE PERSONNEL AND SHALL BE MARKED "FIRE ALARM CONTROL PANEL." 14.FAILURE OF THE BATTERY CHARGER SHALL RESULT IN A TROUBLE SIGNAL IN ACCORDANCE WITH 10.15. NFPA 72 10.6.10.6.2. 15.ALL MODIFICATIONS MADE AFTER THE INITIAL INSTALLATION SHALL BE RECORDED ON A REVISED VERSION OF THE ORIGINAL COMPLETION DOCUMENTS, WHICH SHALL SERVE AS A SUPPLEMENT TO THE ORIGINAL, UNALTERED COMPLETION DOCUMENTS. NFPA 72, 7.5.6.6.1. 16.WHERE THE BATTERY IS NOT MARKED W/ THE MONTH/YEAR BY THE MANUFACTURE, THE INSTALLER SHALL OBTAIN THE DATE CODE AND MARK THE BATTERY WITH THE MONTH/YEAR OF BATTERY MANUFACTURE. NFPA 72, 10.6.10.1.2. 17.BATTERIES SHALL BE MARKED WITH THE MONTH AND YEAR OF MANUFACTURE USING THE MONTH/YEAR FORMAT. NFPA 72, 10.6.10.1.1. 18.FIRE ALARM CIRCUITS SHALL BE GROUNDED IN ACCORDANCE WITH C.E.C.-ARTICLE 250. 19.POWER LIMITED CABLE WHICH IS RUN WITHIN 7 FT. OF THE FINISHED FLOOR MUST BE PROTECTED FROM PHYSICAL DAMAGE ARTICLE 760.130(B)(1). 20.ELECTRICAL POWER CIRCUITS SUPPLYING FIRE ALARM SYSTEMS SHALL BE A DEDICATED BRANCH CIRCUIT. THE CIRCUITS SHALL BE MECHANICALLY PROTECTED CAPABLE OF BEING LOCKED IN THE ON POSITION WITH AN APPROVED MECHANICAL CLIP. CIRCUIT DISCONNECT MEANS SHALL HAVE "RED MARKING", ACCESSIBLE TO ONLY AUTHORIZED PERSONNEL AND BE IDENTIFIED AS "FIRE ALARM CIRCUIT". THE LOCATION OF THE CIRCUIT DISCONNECT MEANS SHALL BE PERMANENTLY IDENTIFIED AT FIRE ALARM CONTROL PANEL. 21.THROUGH PENETRATION FIRE STOPPING FOR ALL FIRE WALLS, FLOORS/CEILINGS AND ASSEMBLIES SHALL HAVE AN F OR T RATING PER THE CBC AND STANDARDS. INSTALLATION OF THE FIRE STOPPING SHALL COMPLY WITH APPROVED METHODS. 22.THE CIRCUIT DISCONNECT DISCONNECT BREAKER PROVIDING POWER TO THE FIRE ALARM UNIT SHALL ONLY BE ACCESSIBLE TO AUTHORIZED PERSONNEL AND SHALL IDENTIFIED AS "FIRE ALARM CIRCUIT". 23.WHERE DETECTION IS NOT REQUIRED DURING CONSTRUCTION, DETECTORS SHALL BE INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE COMPLETED CLEANUP. NFPA 72, 17.7.1.12.3. 24.THE OPERATION OF FIRE EXTINGUISHING SYSTEMS OR SUPPRESSION SYSTEMS SHALL INITIATE AN ALARM SIGNAL BY ALARM-INITIATING DEVICES INSTALLED IN ACCORDANCE WITH THEIR INDIVIDUAL LISTINGS. NFPA 72 17.14. 25.THE SYSTEM SHALL REPORT TO A CENTRAL STATION, POINT TO POINT, DEVICE SPECIFIC. 26.ALL SMOKE DETECTORS, INCLUDING DUCT DETECTORS, SHALL BE TESTED WITH SMOKE, REFER TO MANUFACTURE FOR TYPE OF SMOKE. NFPA 72, 14.4.3.2. 27.THE SECONDARY POWER SUPPLY SHALL HAVE SUFFICIENT CAPACITY SUPPLY TO OPERATE THE SYSTEM UNDER QUIESCENT LOAD (SYSTEM OPERATING IN NON-ALARM CONDITIONS) FOR A MINIMUM 24 HRS AND AT THE END OF THAT PERIOD, SHALL BE CAPABLE OF OPERATING ALL ALARM NOTIFICATION APPLIANCES USED FOR EVACUATION OR TO DIRECT AID TO THE LOCATION OF AN EMERGENCY FOR 5 MINUTES, UNLESS OTHERWISE PERMITTED OR REQUIRED BY 10.6.7.2.1.1 THROUGH 10.6.7.2.2. NFPA 72, 10.6.7.2.1. 28.CONTRACTOR REQUIRED TO PROVIDE DECIBEL METER DURING FINAL ACCEPTANCE TESTING TO FIELD VERIFY AUDIBLE CHARACTERISTICS. NO FINAL WILL BE GIVEN BY FIRE DEPARTMENT UNLESS REQUIRED AUDIBILITY IS FIELD VERIFIED. 29.DESIGNER HAS VERIFIED ALL NEW FIRE ALARM EQUIPMENT TO BE INSTALLED IS BACKWARD COMPATIBLE WITH EXISTING FIRE ALARM EQUIPMENT. 30.ITS THE CONTRACTORS RESPONSIBILITY TO MAKE WORK AVAILABLE FOR INSPECTION. 31.EXTERIOR COMPONENTS SHALL BE MOUNTED IN A WEATHER TIGHT MANNER. 32.BELL SHALL NOT BE ON A SILENCEABLE ZONE 33.SYSTEM WILL BE U.L CERTIFED AVANTGUARD MONITORING CENTERS LLC 4699 HARRISON BLVD., SUITE 100 OGDEN, UT 84403 FILE-VOL # S3955-1 CCN: UUFX LISTING CATEGORY: PROTECTIVE SIGNALING SERVICES FIRE ALARM EQUIPMENT SCHEDULE QTY.SYMBOL DESCRIPTION MANUFACTURE & PART #CSFM #ROUGH IN 1 FIRE ALARM CONTROL PANEL W/ TWO BATTERIES HONEYWELL VISTA-32FBPT BAT-1270-BP (12V 7AH) 7165 - 1645 :0123 N/A 1 FIRE ALARM WIRELESS CELLULAR COMMUNICATOR AES 7788F-ULP 7300 - 1516 :0108 N/A 1 CEILING MOUNT SMOKE DETECTOR SYSTEM SENSOR 2W-B 7272 - 1653 :0152 4" SQUARE W/ SINGLE GANG 1 OS & Y CONNECTION ONLY BY OTHERS N/A N/A 1 WATER FLOW CONNECTION ONLY BY OTHERS N/A N/A 1 TAMPER SWITCH CONNECTION ONLY BY OTHERS N/A N/A 1 WATER FLOW BELL BY OTHERS N/A N/A 1 DOCUMENT BOX NEAR FIRE PANEL SPACE AGE ELECTRONICS SSU00689 7300 - 0553 :0110 N/A FACP FAC S P WF VS D TYPICAL MOUNTING HEIGHTS N.T.S. 12 " M A X . CEILING MOUNT SMOKE/HEAT DETECTOR WALL MOUNT SMOKE/HEAT DETECTOR 3'-0" MIN.15'-0" MAX. SMOKE DETECTOR 25'-0" MAX. HEAT DETECTOR 6" DOOR WIDTH LESS 3" MAGNETIC DOOR HOLDER AUDIO DEVICE AUDIO/VISUAL OR VISUAL DEVICE 6" MIN. BELOW CEILING 90 " M I N . T O B O T T O M O F D E V I C E 80 " - 9 6 " E N T I R E L E N S FINISH WALLFINISH FLOOR CEILING 42" MIN. 48" MAX. TO PULL HANDLE A.F.F. MANUAL PULL STATION FIRE FIGHTER'S PHONE JACK 5' - 6 " CONTROL PANEL GRAPHIC ANNUNCIATOR PROJECT NUMBER CHECKED BY: DRAWN BY: DATE: BY RE V I S I O N S RE V DA T E DE S C R I P T I O N APPROVALS APDF142176-1 4/12/2024 FI R E S P R I N K L E R M O N I T O R I N G S Y S T E M DE S E R T C L U B A P A R T M E N T S 51 4 8 0 D E S E R T C L U B D R I V E LA Q U I N T A , C A 9 2 2 5 3 E.V. MATTHEW PATNAUDE NICET III # 146793 FA-1 EV 1 5/ 2 2 / 2 0 2 4 CO R R E C T I O N S 75-130 St. Charles Pl. Palm Desert, CA 92211 Lic# 1084934 | ACO 5773 TEL. 760.341.3593 Mailing Address: P.O. Box 14323 Palm Desert, CA 92255AV E N I D A B E R M U D A S SITE AVENIDA LA FONDA 52ND A V E DE S E R T C L U B D R AV E N I D A N A V A R R O AVENIDA NUESTRA BATTERY CALCULATION FACP (VISTA-32FBPT) SUPERVISORY CURRENT PER DEVICE ALARM CURRENT QTY.DEVICE & MODEL STAND-BY TOTAL STAND-BY ALARM TOTAL ALARM 1 FIRE ALARM CONTROL PANEL HONEYWELL VISTA-32FBPT 0.3450 0.3450 0.6300 0.6300 1 SMOKE DETECTOR SYSTEM SENSOR 2W-B 0.0005 0.0005 0.1300 0.1300 0 MANUAL PULL STATION HONEYWELL 5140MPS-1 0.0004 0.0000 0.0004 0.0000 0 SYSTEM SENSOR PC2WL CEILING HORN STROBE @ 15cd.0.1030 0.0000 0 SYSTEM SENSOR P2WL WALL MOUNT HORN STROBE @ 15cd.0.0980 0.0000 TOTAL 0.3455 0.7600 TOTAL ALARM CURRENT X .084 (5MIN.= 0.084 HOURS)0.084 0.0638 TOTAL SUPERVISORY CURRENT X 24 HOURS 24 8.2920 TOTAL AMP HOUR REQUIRED (ALARM CURRENT + SUPERVISORY CURRENT)8.3558 TOTAL AMP HOUR X 1.25 SAFETY FACTOR 1.25 10.4448 BATTERIES SUBMITTED: (2) BATTERIES - 7 A.H. (PARALLEL = 14 A.H.) SEQUENCE OF OPERATION FA C P / F A A : A L A R M FA C P / F A A : S U P E R V I S O R Y FA C P / F A A : T R O U B L E AC T I V A T E A L L N O T I F I C A T I O N A P P L I A N C E S MO N I T O R I N G S T A T I O N A L A R M MO N I T O R I N G S T A T I O N S U P E R V I S O R Y MO N I T O R I N G S T A T I O N T R O U B L E AC T I V A T E R I S E R W A T E R F L O W B E L L SMOKE DETECTOR X X X OS & Y X X SUPERVISORY TAMPER VALVE X X WATERFLOW SWITCH X X X X FIRE ALARM AC POWER FAIL X X FIRE ALARM SYSTEM LOW BATTERY X X OPEN CIRCUIT X X GROUND FAULT X X NOTIFICATION APPLIANCE SHORT CIRCUIT X X CELLULAR COMMUNICATOR X X C-10 LICENSE NO.: 1084934 1 1 1 1 KITCHEN KITCHEN COVERED PATIO DINING DINING COVERED PATIO COVERED PATIO COVERED PATIO KITCHENDINING UNIT 106 UNIT 107 UNIT 108 UNIT 105 KITCHEN DINING BEDROOM BATHROOM MASTER BATHROOM MASTER BEDROOM MASTER CLOSET MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL MODELNUMBERTRADENAMEPRODUCTMATERIAL BEDROOM BATHROOM MASTER BATHROOM MASTER BEDROOM MASTER CLOSET BEDROOM BATHROOM MASTER BATHROOM +8'-10"MASTER BEDROOM MASTER CLOSET BEDROOM BATHROOM MASTER BATHROOM MASTER BEDROOM MASTER CLOSET FIRE ALARM RISER DIAGRAM N.T.S. F A C P 120 VAC 120 VAC 120 VAC EOL ZONE 1 TO POSITIVE SIDE OF BATTERY TO NEGATIVE SIDE OF BATTERY FAC S P VS WF EOL ZONE 3 EOL ZONE 4 EOL ZONE 5 MANUAL PULL STATION WIRING DETAIL, TYP. N.T.S. SLC -+ SLC SMOKE DETECTOR WIRING DETAIL, TYP. N.T.S. EOL RESISTOR RA100ZRA100Z 2-WIRE CONTROL PANEL (1 ) + I N (2 ) + O U T (3 ) + I N / O U T (4 ) R A + (5 ) R A - 2W-B OR 2WT-B 2W-B OR 2WT-B (1 ) + I N (2 ) + O U T (3 ) + I N / O U T (4 ) R A + (5 ) R A - 2-WIRE + ZONE - SYSTEM SENSOR - HORN/STROBE - STROBE N.T.S. INPUT FROM FACP OR PRIOR DEVICE OUTPUT TO NEXT DEVICE OR EOL PROJECT NUMBER CHECKED BY: DRAWN BY: DATE: BY RE V I S I O N S RE V DA T E DE S C R I P T I O N APPROVALS APDF142176-1 4/12/2024 FI R E S P R I N K L E R M O N I T O R I N G S Y S T E M DE S E R T C L U B A P A R T M E N T S 51 4 8 0 D E S E R T C L U B D R I V E LA Q U I N T A , C A 9 2 2 5 3 E.V. MATTHEW PATNAUDE NICET III # 146793 FA-2 EV 1 5/ 2 2 / 2 0 2 4 CO R R E C T I O N S 75-130 St. Charles Pl. Palm Desert, CA 92211 Lic# 1084934 | ACO 5773 TEL. 760.341.3593 Mailing Address: P.O. Box 14323 Palm Desert, CA 92255 FIRE SPRINKLER MONITORING SYSTEM PLAN - DESERT CLUB APARTMENTS SCALE: 1/8" = 1'-0" VS WFEOL ZONE 3 EOL ZONE 4 FA-2 A ENLARGED RISER ROOM PLAN SCALE: 1/2" = 1'-0" D FACFACP A EOL ZONE 5 FROM FACP IN RISER ROOM, SEE ENLARGED PLAN, A/FA-2. FROM FACP IN RISER ROOM, SEE ENLARGED PLAN, A/FA-2. TO OS & Y, SEE FLOOR PLAN, FA-2. S P WIRE SCHEDULE MANUFACTURER WIRE GAUGE/ CONDUCTORS/ TYPE WIRE DESCRIPTION / USE PATHWAY SURVIVABILITY & CLASS DESIGNATION GENESIS 18 AWG 2C FPLR SIGNAL LINE CIRCUIT SURVIVABILITY LEVEL 0 CLASS B NOTES: 120 VAC C-10 LICENSE NO.: 1084934 FIRE ALARM EQUIPMENT SCHEDULE QTY.SYMBOL DESCRIPTION MANUFACTURE & PART #CSFM #ROUGH IN 1 FIRE ALARM CONTROL PANEL W/ TWO BATTERIES HONEYWELL VISTA-32FBPT BAT-1270-BP (12V 7AH) 7165 - 1645 :0123 N/A 1 FIRE ALARM WIRELESS CELLULAR COMMUNICATOR AES 7788F-ULP 7300 - 1516 :0108 N/A 1 CEILING MOUNT SMOKE DETECTOR SYSTEM SENSOR 2W-B 7272 - 1653 :0152 4" SQUARE W/ SINGLE GANG 1 OS & Y CONNECTION ONLY BY OTHERS N/A N/A 1 WATER FLOW CONNECTION ONLY BY OTHERS N/A N/A 1 TAMPER SWITCH CONNECTION ONLY BY OTHERS N/A N/A 1 WATER FLOW BELL BY OTHERS N/A N/A 1 DOCUMENT BOX NEAR FIRE PANEL SPACE AGE ELECTRONICS SSU00689 7300 - 0553 :0110 N/A FACP FAC S P WF VS D 1 EOL ZONE 1 1 1 1 The approval of plans and specications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. Riverside County Fire Department Oce of the Fire Marshal APPROVAL By: Permit # : Chris Cox, Fire Safety Supervisor 06/05/2024 FA2024-0003