Loading...
FSS2023-0001BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 01/02/2023 ISSUED DATE: 01/24/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Fire Sprinkler System - Commercial 51480 DESERT CLUB DR FSS2023-0001 770156010 L SEE MAP H-P MB 19/75 DESERT CLUB TR UNIT $62,750.00 VC, SEE MAP H-P Owner:South West Concepts, Inc. 78115 Calle Estado #105, La Quinta, CA 92253 Applicant:Blake Chapman 41-905 BOARDWALK STE B, PALM DESERT, CA 92211 Contractor:WORLD FIRE PROTECTION INC 41-905 BOARDWALK STE B, PALM DESERT, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/18/25 9:59 am Page 1 of 4 Permit Type: Permit Number: Property Address: Fire Sprinkler System - Commercial FSS2023-0001 51480 DESERT CLUB DR BUILDING PERMIT application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 9/18/25 9:59 am Page 2 of 4 Permit Type: Permit Number: Property Address: Fire Sprinkler System - Commercial FSS2023-0001 51480 DESERT CLUB DR BUILDING PERMIT DESERT CLUB APARTMENT - NORTH & GARAGE S-2 *** Use of Permit Construction Details 131Number of Sprinkler Heads 1000Building Square Feet - Protected VCZoning VCGeneral Plan Within La Quinta LimitsCity Limits DESERT CLUB TR UNITSubdivision Name SEE MAP H-PLot Number 4419.52Lot Size 98224, 17232, 96673Centerlines L SEE MAP H-P MB 19/75 DESERT CLUB TR UNIT Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00003774 $11.00 RECORDS MANAGEMENT FEE $11.00 $18.78 Credit Card Convenience Fee $18.78 $732.00 Fire - Sprinkler System - 1 Commercial/Industrial $732.00 $8.00 TECHNOLOGY ENHANCEMENT FEE $8.00 $769.78 $769.78 Total for Invoice INV-00003774 INV-00006124 $183.00 Fire - Failed or Additional Field Inspections $183.00 $4.58 Credit Card Convenience Fee $4.58 $187.58 $187.58 Total for Invoice INV-00006124 INV-00006970 $183.00 Fire - Failed or Additional Field Inspections $183.00 $4.58 Credit Card Convenience Fee $4.58 $187.58 $187.58 Total for Invoice INV-00006970 INV-00011280 $183.00 Fire - Failed or Additional Field Inspections $183.00 $183.00 $183.00 Total for Invoice INV-00011280 Grand Total for Permit $1,327.94 $1,327.94 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Linked Records v.1 01/17/2024 13:58 12/09/2024 13:34 Linked Permits v.1 Create Sub Permit 01/17/2024 13:58 12/09/2024 13:34 Revisions v.1 12/05/2023 0:00 01/17/2024 13:49 Fire Revision Review v.1 Receive Submittal 12/05/2023 0:00 12/19/2023 17:00 Fire Revision Review v.2 Receive Submittal 01/08/2024 0:00 01/09/2024 17:39 Fire Revision Review v.3 Receive Submittal 01/12/2024 0:00 01/17/2024 13:49 Fire Inspections v.1 01/26/2024 11:12 FIRE - OH Rough Piping (Comm) v.1 Inspection 01/26/2024 11:12 01/30/2024 15:01 FIRE - OH Rough Piping (Comm) v.1 Inspection 06/05/2024 14:51 06/10/2024 7:55 FIRE - OH Rough Piping (Comm) v.2 Inspection 01/30/2024 15:01 02/01/2024 15:24 FIRE - OH Rough Piping (Comm) v.3 Inspection 02/05/2024 14:22 02/06/2024 17:45 FIRE - OH Rough Piping (Comm) v.4 Inspection 02/07/2024 14:18 02/12/2024 12:26 Printed: 9/18/25 9:59 am Page 3 of 4 Permit Type: Permit Number: Property Address: Fire Sprinkler System - Commercial FSS2023-0001 51480 DESERT CLUB DR BUILDING PERMIT FIRE - OH Rough Piping (Comm) v.5 Inspection 04/04/2024 16:38 04/09/2024 12:43 FIRE - OH Rough Piping (Comm) v.6 Inspection 04/16/2024 13:58 04/16/2024 14:02 FIRE - OH Rough Piping (Comm) v.7 Inspection 04/17/2024 15:30 04/18/2024 17:47 FIRE - OH Rough Piping (Comm) v.8 Inspection 04/25/2024 11:06 04/29/2024 14:10 FIRE - OH Hydro v.1 Inspection 01/26/2024 11:13 01/30/2024 15:01 FIRE - OH Hydro v.2 Inspection 01/30/2024 15:01 02/01/2024 15:25 FIRE - OH Hydro v.3 Inspection 02/05/2024 14:22 02/06/2024 17:46 FIRE - OH Hydro v.4 Inspection 02/07/2024 14:18 02/12/2024 12:26 FIRE - OH Hydro v.5 Inspection 04/04/2024 16:38 04/09/2024 12:44 FIRE - OH Hydro v.6 Inspection 04/16/2024 13:58 04/16/2024 14:03 FIRE - OH Hydro v.7 Inspection 04/17/2024 15:31 04/18/2024 17:47 FIRE - OH Hydro v.8 Inspection 04/25/2024 11:06 04/29/2024 14:13 FIRE - OH Hydro v.9 Inspection 06/05/2024 14:52 06/10/2024 7:55 Fire Sprinkler Final 13/13R v.1 Inspection 10/03/2024 10:26 10/04/2024 19:17 Fire Sprinkler Final 13/13R v.2 Inspection 12/17/2024 11:25 12/18/2024 17:07 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 9/18/25 9:59 am Page 4 of 4 OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org December 19, 2023 World Fire Protection Re: Desert Club Apartments - Fire Sprinkler System Permit FSS2023-0001 / 51480 Desert Club Drive, La Quinta The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and require the following corrections and additional details. 1.) Correct the address number noted on the plan sheets. 2.) Note the applicable edition of NFPA 13R / 13 (2022). 3.) Show the fixed pressure loss for the backflow preventor on the hydraulic calculations. 4.) The pipe and fittings proposed to be located outside and exposed to weather (between the garage building and apartment building) are required to be able to withstand corrosion. Confirm this equipment is suitable for the outdoors. NFPA 13: 16.4.2.3 5.) Show how the seismic separation assembly will be installed for the pipe between the garage building and the apartment building. NFPA 13: 18.3.1 Note the location of the fire department connection (F.D.C.) and the post indicating valves (P.I.V.) All questions regarding the meaning of these requirements should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox – Fire Safety Supervisor OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org January 9, 2024 World Fire Protection Re: Desert Club Apartments - Fire Sprinkler System Permit FSS2023-0001 / 51480 Desert Club Drive, La Quinta The plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and require the following corrections and additional details. 1.) The sprinkler plans for 51520 Desert Club Drive were submitted to this permit which is for 51480 Desert Club Drive. Submit the plans for 51480 Desert Club Drive. All questions regarding the meaning of these requirements should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox – Fire Safety Supervisor OFFICE OF THE FIRE MARSHAL – LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7078 • www.rvcfire.org January 12, 2024 World Fire Protection Re: New Fire Sprinkler System – Desert Club Apartments FSS2023-0001 / 51480 Desert Club Drive The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. 1) The fire sprinkler system shall be monitored and supervised by an approved Dedicated Function - Fire Sprinkler Monitoring System. 2) Each system shall have an Air-Relief valve in compliance with NFPA 13 installed in a remote, most elevated location. 3) CA compliant Hydraulic Calculation Placards shall be installed on the riser or other approved location. Risers shall have signage indicating the location of remotely located placards. 4) The following inspections/tests are required to be witnessed by Office of the Fire Marshal staff: a) Overhead Rough: All installed/relocated piping must be visible. b) Overhead Hydro: Entire system shall be hydrostatically tested at a minimum of 200 psi for 2 hours. c) Underground Supply Flush: Flush of the underground supply line until clear of all debris and to the satisfaction of the inspector. d) Final inspection: Water-flow signal test as performed from the inspector test valve. As-Built plans required to be maintained on site as approved by the inspector. General Information sign and Hydraulic Calculation plate(s) provided. NOTE: The underground flush shall be done through a pipe or hose equal in size to the sprinkler underground supply pipe, prior to connection to the above ground sprinkler piping. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7078. Chris Cox - Fire Safety Supervisor 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 RIVERSIDE COUNTY FIRE PROTECTION PLANNING RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 51480 Desert Club Drive PERMIT#: FSS2023-0001 DATE ISSUED: 1/12/24 DESCRIPTION: Fire Sprinkler System CONTRACTOR: World Fire Protection HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre-pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final E F Thrust block pre-pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final E F Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors’ test Hood/duct extinguishing High pile storage High pile rack storage In-rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final E F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final E F FIRE ALARM KNOX SYSTEM Rough-wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections email FireBusinessMail@laquintaca.gov B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE-INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. Page 1 of 4 MARCH 2022 TFP403 Worldwide Contacts www.tyco-fire.com IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/series-lfii- res-4_9-k-pen-sprinkler-wet Series LFII Residential 4.9 K-factor Pendent Sprinkler Wet Pipe Systems General Description TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers (TY2236) are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII Residential Sprinklers (TY2236) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet pipe residential sprinkler sys- tems for one- and two-family dwell- ings and mobile homes per NFPA 13D • wet pipe residential sprinkler sys- tems for residential occupancies up to and including four stories in height per NFPA 13R • wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings when used with one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by either Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable Approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2236) described herein must be installed and maintained in compli- ance with this document and the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY2236 TY2236 is a replacement for the TY2234. TFP403 Page 2 of 4 SURFACE ESCUTCHEON PLATE SEATING 1-5/8" (41,3 mm) -2 Button Temperature rating is indicated on Deector. Deector Compression Screw Bulb Sealing Assembly -6 * -4 5 - 3 - * * 6 4 5 1 3 2 Components: Frame1- 1/2" NPT 7/16" (11,1 mm) MAKE-IN NOMINAL ESCUTCHEON STYLE 15 or 20 RECESSEDWRENCH (57,2 mm) 2-1/4" FLATS (73,0 mm) 2-7/8" DIA. CROSS SECTION PENDENT RECESSED PENDENT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8" (3,2 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING 3/8±5/16" (9,5±7,9 mm) TY2236CLOSURE 5/8" (15,9 mm) FLUSH 1-9/16" (39,7 mm) 15/16" (23,8 mm) 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING PLATE 1/8" (3,2 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING 5/16±1/4" (7,9±6,4 mm) TY2236CLOSURE 1-9/16" (39,7 mm) 1-1/16" (27,0 mm) 1/2" (12,7 mm) FLUSH RECESS WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH WRENCH RECESS (END "A" USED FOR TY2236) FIGURE 1 SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2236) FIGURE 2 SERIES LFII RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON FIGURE 3 SERIES LFII RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH FIGURE 4 W-TYPE 6 SPRINKLER WRENCH TFP403 Page 3 of 4 Technical Data Approvals UL and C-UL Listed Certified to all requirements of NSF/ANSI 61 Note: Sprinklers with a polyester finish are UL Listed as corrosion-resistant sprinklers. See the Design Criteria section for details on these approvals. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi½ (70,6 lpm/bar ½) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White Polyester Coated, Signal White Polyester Coated, Jet Black Polyester Coated, or Chrome Plated Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Button . . . . . . . . . . . . . . . . . . . . . . . . . . . Copper Sealing Assembly ..Beryllium Nickel w/TEFLON Bulb (3 mm) . . . . . . . . . . . . . . . . . . . . . . . . Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers are UL and C-UL Listed for instal- lation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing and the C-UL Listing, wet pipe systems may be utilized. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum re quired sprin- kler flow rates are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft² over the design area comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1 1/4 in. to 4 in. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. Maximum Coverage Area (1) ft x ft (m x m) WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Ordinary Temperature Rating 155°F (68°C)Intermediate Temperature Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing ft (m) Flow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3,7 x 3,7) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48)Smooth Ceilings 1-1/4 in. to 4 in. Beamed Ceilings per NFPA 13D or 13R 1-1/4 in. to 1-3/4 in. below bottom of beam. Recessed us- ing either Style 15 or Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) 16 x 16 (4,9 x 4,9)13 (49,2)7.0 (0,48)13 (49,2)7.0 (0,48) 18 x 18 (5,5 x 5,5) 17 (64,3) 12.0 (0,83) 17 (64,3) 12.0 (0,83) 20 x 20 (6,1 x 6,1) 20 (75,7) 16.7 (1,15) 20 (75,7) 16.7 (1,15) Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm (lpm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2236) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP403 Page 4 of 4 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a trademark of The Chemours Company FC, LLC 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Installation TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N∙m). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, as shown in Figure 4. With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install the recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing either the Style 15 or the Style 20 Mounting Plate over the sprinkler threads, and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, as shown in Figure 5. With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed, or the finish coat has been applied, slide on either the Style 15 Closure or the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance TYCO Series LFII Residential 4.9K Pendent and Recessed Pendent Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION, such as NFPA 25, in addi- tion to the standards of any authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII 4.9K Residential Pendent Sprinkler (TY2236), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .................51-212-1-155 Pure White (RAL 9010) Polyester1, 2 ..................51-212-3-155 Signal White (RAL 9003) Polyester1 ....................51-212-4-155 Jet Black (RAL 9005) Polyester1 ....................51-212-5-155 Chrome Plated ................51-212-9-155 175°F (79°C) Natural Brass ..................51-212-1-175 Pure White (RAL 9010) Polyester1, 2 ..................51-212-3-175 Signal White (RAL 9003) Polyester1 ....................51-212-4-175 Jet Black (RAL 9005) Polyester1 ....................51-212-5-175 Chrome Plated . . . . . . . . . . . . . . . . 51-212-9-175 1. UL Listed as corrosion-resistant. 2. Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 15 Escutcheon with (specify*) finish, P/N (specify*) or Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 10 JULY 2010 TFP171 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Technical Services 800-381-9312 | +1-401-781-8220 www.tyco-fire.com General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2 ˝ NPT TY1231: Pendent 2.8K, 1/2 ˝ NPT TY2131: Upright 4.2K, 1/2 ˝ NPT TY2231: Pendent 4.2K, 1/2 ˝ NPT TY3131: Upright 5.6K, 1/2 ˝ NPT TY3231: Pendent 5.6K, 1/2 ˝ NPT TY4131: Upright 8.0K, 3/4˝ NPT TY4231: Pendent 8.0K, 3/4˝ NPT TY4831: Upright* 8.0K, 1/2 ˝ NPT TY4931: Pendent* 8.0K, 1/2 ˝ NPT *Eastern Hemisphere Sales Only TFP171 Page 2 of 10 WRENCH (38,1 mm)(55,6 mm) 2-7/8" (73,0 mm) DIA. 1 3 1/2" NPT SSP DEFLECTOR FLATS STYLE 10 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) 5 4 2 6 7/16" MAKE-IN NOMINAL (11,1 mm) 2-3/16" DEFLECTOR SSU ESCUTCHEON PLATE SEATING (55,6 mm) SURFACE 1-1/2" 1/2" NPT NOMINAL MAKE-IN 2-3/16" RECESSED PENDENTCROSS SECTION UPRIGHT PENDENT * * * FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT SSP DEFLECTOR 2-1/4" (57,2 mm) (39,7 mm) 1-9/16" PLATE SEATING SURFACE ESCUTCHEON 1/2" NPT WRENCH FLATS MAKE-IN NOMINAL 7/16" (11,1 mm) MAKE-IN NOMINAL (11,1 mm) 7/16" 2-3/16" (55,6 mm) SSU DEFLECTOR 2 7 1 3 5 4 6 2-7/8" (73,0 mm) DIA. RECESSED STYLE 10 or 20 ESCUTCHEON 1/2" NPT * * * 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 7 - Bushing 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 3 of 10 SSP DEFLECTOR WRENCH(55,6 mm) 1 3 1/2" NPT FLATS 5 4 2 6 7/16" (11,1 mm) SSU DEFLECTOR 7/16" 2-3/16" NOMINAL MAKE-IN (11,1 mm) NOMINAL MAKE-IN 1/2" NPT (38,1 mm) 2-7/8" (73,0 mm) DIA. STYLE 10 or 20ESCUTCHEON 2-3/16" (55,6 mm) 1-1/2" PLATE SEATING SURFACE RECESSED ESCUTCHEON PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT * * * (39,7 mm)(57,2 mm) 1 3 3/4" NPT SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. (12,7 mm) MAKE-IN NOMINAL 5 4 2 2-1/4" 6 ESCUTCHEON1/2" (12,7 mm) 1/2" DEFLECTOR SSU NOMINAL MAKE-IN 1-9/16" 2-5/16" (58,7 mm) PLATE SEATING SURFACE3/4" NPT STYLE 30 or 40 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT * * * FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 4 of 10 † Registered Trademark of Dupont Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical CharacteristicsFrame. . . . . . . . . . . . . . . . . . .Bronze Button. . . . . . . . . . . . . .Brass/Copper Sealing Assembly . . . . . . . . .Beryllium Nickel w/Teflon† Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . .Bronze Deflector . . . . . . . . . . .Copper/Bronze Bushing (K=2.8) . . . . . . . . . . .Bronze (39,7 mm)WRENCH(55,6 mm)3 1 DEFLECTOR1/2" NPT SSP FLATS DEFLECTOR (11,1 mm) NOMINAL 2 4 5 6 MAKE-IN 2-3/16" 7/16" 7/16" (11,1 mm) 1/2" NPT NOMINAL MAKE-IN SSU 2-1/4" (57,2 mm) 1-9/16" SECTION CROSS PENDENTUPRIGHT * * * FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw inch (1,6 mm) for the 135°F/57°C and 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. Obtain a leak-tight 1/2 inch NPT sprin- kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con- sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. 1. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. 2. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 3. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1, 2, 3, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1, 2 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)** Figure 11 135°F/57°C Orange 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Orange 1, 2, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 2. Tighten the sprinkler into the sprin- kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig- ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. 3. After ceiling installation and finish- ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: • were modified or over-heated. • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • are leaking or exhibiting visible signs of corrosion. • were exposed to corrosive products of combustion but have not oper- ated, if you cannot easily remove combustion by-products with a cloth. • have a cracked bulb or have lost liq- uid from the bulb. Refer to the Instal- lation section in this data sheet. SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131)75 PSI (12,1 BAR)N/A RECESSED PENDENT (TY1231) 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131)175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3231)N/A 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131)175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231)N/A 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831)175 PSI (12,1 BAR)175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE TFP171 Page 8 of 10 Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 13/16" (20,6 mm) 1-5/16" (33,3 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1-1/16" (27,0 mm) 1-5/16" (33,3 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT (57,2 mm) 2-1/4" DIA. (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm) 5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm) 1/2±1/8" 2-1/4" DIA. (57,2 mm) (73,0 mm) 2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (12,7±3,2 mm) 1/2±1/8" 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) MOUNTING PLATE (3,2 mm) 1/8" 1/2" (12,7 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (15,9±6,4 mm) 5/8±1/4" MOUNTING PLATE 1-5/16" (33,3 mm) 13/16" (20,6 mm) (3,2 mm) 1/8" 3/4" (19,1 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) RECESS WRENCH PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREAFIGURE 14 W-TYPE 6 SPRINKLER WRENCH FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. TFP171 Page 10 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP’s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer’s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer- chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS P/N 57 – XXX – X – XXX SPRINKLER FINISH 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) MODEL/SIN 330 2.8K UPRIGHT (1/2”NPT)TY1131 331 2.8K PENDENT (1/2”NPT)TY1231 340 4.2K UPRIGHT (1/2”NPT)TY2131 341 4.2K PENDENT (1/2”NPT)TY2231 370 5.6K UPRIGHT (1/2”NPT)TY3131 371 5.6K PENDENT (1/2”NPT)TY3231 390 8.0K UPRIGHT (3/4”NPT)TY4131 391 8.0K PENDENT (3/4”NPT)TY4231 360 8.0K UPRIGHT (1/2”NPT)TY4831* 361 8.0K PENDENT (1/2”NPT)TY4931* * Eastern Hemisphere sales only. General Description The 8.0 K-factor, Model CHEC (Con- cealed Horizontal Extended Cover- age), Quick Response Light Hazard, Sidewall Sprinklers are decorative, 3 mm bulb type sprinklers featuring a unique cover plate designed to con- ceal the sprinkler. It is the best choice for architecturally sensitive areas such as dormitories, hotel rooms, reception areas, office buildings, banquet facili- ties, conference rooms, and hospitals. The soft contour of the cover plate optimizes a low profile while blending in with surrounding surfaces. The plate, while maintaining a fast re- sponse sensitivity has been specifi- cally designed without vent holes to increase its aesthetic appeal while helping to avoid objects from being hung from the sprinkler (i.e., garment bags, clothes hangers, etc.) that might otherwise cause an inadvertent opera- tion. They are designed for installation along a wall or the side of a beam and beneath a smooth and level ceiling. Horizontal sidewall sprinklers are com- monly used in lieu of pendent or up- right sprinklers because of aesthetics or building construction considera- tions where piping across the ceiling is not desirable. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for light hazard occu- pancies. The fast response thermal sensitivity rating of the Model CHEC Sprinklers provides for a quick re- sponse extended coverage rating up to a 16 ft. x 22 ft. coverage area. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components. The separable two-piece design of the Cover Plate and Support Cup Assemblies allows installation of the sprinklers and pres- sure testing of the fire protection sys- tem prior to the installation of the wall or application of a finish coating. Also, the separable “push-on and thread-off” two-piece design of the the Sprinkler provides for 1/2 inch (12,7 mm) of horizontal adjustment. The Model CHEC Sprinklers are shipped with a Protective Cap. The Protective Cap is temporarily removed for installation, and it can be replaced to help protect the sprinkler while the wall is being plastered, wallpapered, or painted.Whenthewallinstallation is complete the Protective Cap is re- moved and the Cover Plate Assembly installed. WARNINGS The Model CHEC (Concealed Hori- zontal Extended Coverage), Quick Response Light Hazard, Sidewall Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integ- rity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Sprinkler Identification Number TY4332 - ECLH HSW, 8.0K, 3/4"NPT Technical Data Approvals UL and C-UL Listed. (The listings apply only to the service conditions indicated in the Design Cri- teria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=8.0GPM/psi1/2 (115,2 LPM/bar 1/2) Temperature Ratings 135°F/57°C Sprinkler with 135°F/57°C Cover Plate 155°F/68°C Sprinkler with 135°F/57°C Cover Plate Adjustment 1/2 inch (12,7 mm) Finish Cover Plate: Bright White or Chrome Plated. (Custom colors other than white are available on special re- quest.) Physical Characteristics Frame ............ Bronze Button ........Bronze/Copper Button Spring . . . . Stainless Steel SealingAssembly.......... . . . . . . Beryllium Nickel w/Teflon† Bulb, 3 mm Diameter . . . . . Glass Model CHEC — 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers Page 1 of 6 TFP265JANUARY, 2003 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Deflector ............Brass Compression Screw . . . . . Bronze SupportCup .......... Steel Retainer ............Brass Cover Plate . . . . . . . . . . . Brass Cover Plate Ejection Spring . . . . . ............StainlessSteel Patents Patents are pending. Operation When exposed to heat from a fire, the Cover Plate, which is soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The Model CHEC Sprinklers are UL and C-UL Listed for use in light hazard occupancies, using the design criteria in Table A, in addition to the require- ments specified inthecurrentNFPA13 for extended coverage sidewall sprin- klers. The Model CHEC Sprinklers are only listed and approved with the Model CHEC Cover Plates having a factory applied finish. Installation The Model CHEC Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over-tightening the Sprinkler/Support Cup Assembly. Page2of6 TFP265 FIGURE 1 MODEL CHEC (CONCEALED HORIZONTAL EXTENDED COVERAGE) QUICK RESPONSE LIGHT HAZARD SIDEWALL SPRINKLER — ASSEMBLY — SURFACE UNTIL RETAINER FLANGE IS FLUSH WITH MOUNTING PUSH INTO SUPPORT CUP WITH THREAD THREADS SUPPORT CUP WITH ROLL FORMED SPRING EJECTION BUTTON SPRINKLER/SUPPORT CUP ASSEMBLY SEALING BUTTON 3/4" NPT FLATS WRENCH COMPRESSION ASSEMBLY BULB SCREW TOP FRAME DEFLECTOR PLATE COVER COVER PLATE/RETAINER ASSEMBLY SOLDER TABS (3) RETAINER DIMPLES COVER PLATE EJECTION SPRING Readjust the position of the sprinkler fitting to suit. Step 1.The sprinkler must only be installed with its centerline perpen- dicular to the back wall and parallel to the ceiling. The word “TOP” on the de- flector is to face towards the ceiling. Step 2.Remove the Protective Cap. Step 3.With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4.Wrench tighten the sprinkler using only the W-Type 7 Wrench (Ref. Figure 3). The wrench recess of the W-Type 7 Wrench is to be applied to the Sprinkler Wrench Flats shown in Figures 1 and 2. Step 5.Replace the Protective Cap (Ref. Figure 4) by pushing it inwards until it bottoms out against the Support Cup.The Protective Cap helps prevent damage to the Sprinklerto help protect the sprinkler while the wall is being plastered, wallpapered, or painted. NOTE As long as the Protective Cap remains in place, the system is considered to be “Out of Service”. Step 6. After the wall has been com- pleted with the nominal 2-1/2 inch (63,5mm)diameter mountingholeand in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap.If the Sprinkler has been damaged in any way including accidental over spray from finishing the wall, replace the entire Sprin- kler/Support Cup Assembly. Step 7.Push the Cover Plate/Re- tainer Assembly into the Support Cup, and as necessary, make the final ad- justment of the Cover Plate with re- spect to the wall by turning the Cover Plate/Retainer Assembly clockwise until its flange just comes in contact with the wall. If it becomes necessary to remove the Cover Plate, it can be removed by un- screwing in a counter-clockwise direc- tion. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the wall, the Sprinkler Fitting must be repositioned. TFP265 Page 3 of 6 FIGURE 2 MODEL CHEC (CONCEALED HORIZONTAL EXTENDED COVERAGE) QUICK RESPONSE LIGHT HAZARD SIDEWALL SPRINKLER — INSTALLATION DIMENSIONS — COVER PLATESPRINKLER MANUFACTURER (60,3 to 66,7 mm) 2-3/8" to 2-5/8" DIA. 1/2" (12,7 mm) THREADED ADJUSTMENT SPRINKLER FACE OF FITTING (22,2 to 34,9 mm) 7/8" to 1-3/8" RETAINER FLANGE MOUNTING SURFACE SUPPORT CUP ASSEMBLY 5/32" (4,0 mm) PRESET GAP (44,5 mm) (42,9 mm) 1-11/16" 1-3/4" ASSEMBLY RETAINER 3-5/16" DIA. (84,1 mm) CENTERLINE WATERWAY OF SPRINKLER 7/16" (11,1 mm) TOP OF DEFLECTOR (14,3 mm) 9/16" FLATS WRENCH SIDE VIEW Care and Maintenance The Model CHEC Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES When properly installed, there is a nominal 5/32 inch (4,0 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the wall is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Page4of6 TFP265 Response Coverage Minimum Minimum Deflector- Sprinkler Lateral Rating Area (1), Flow (2), Pressure (2), To-Ceiling Temperature Minimum Ft. x Ft. (m x m) GPM (LPM) PSI (BAR) Distance (3), In. (mm) Rating, °F Spacing (4), Ft. (m) Quick 16 x 14 (4,9 x 4,3) 26 (98) 10.6 (0,73) 4 to 12 (100 to 300) 135 or 155 10 (3,1) Quick 16 x 16 (4,9 x 4,9) 26 (98) 10.6 (0,73) 4 to 12 (100 to 300) 135 or 155 10 (3,1) Quick 16 x 18 (4,9 x 5,5) 29 (110) 13.1 (0,90) 4 to 12 (100 to 300) 135 10 (3,1) Quick 16 x 20 (4,9 x 6,1) 36 (136) 20.3 (1,40) 4 to 12 (100 to 300) 135 10 (3,1) Quick 16 x 22 (4,9 x 6,7) 36 (136) 20.3 (1,40) 4 to 12 (100 to 300) 135 10 (3,1) TABLE A UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA NOTES 1. Backwall (where sprinkler is located) by sidewall (length of throw). 2. Requirement is based on minimum flow in GPM from each sprinkler. The indicated residual pressures are based on the nominal K-factor. 3. The centerline of the sprinkler waterway is located 7/16 inch (11,1 mm) below the deflector (Ref. Figure 2). 4. Minimum spacing is for lateral distance between sprinklers located along a single wall. Otherwise adjacent sprinklers (i.e., sidewall sprinklers on an adjacent wall, on an opposite wall, or pendent sprinklers) must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. FIGURE 3 W-TYPE 7 SPRINKLER WRENCH FIGURE 4 PROTECTIVE CAP RECESS WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH CAP PROTECTIVE Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed.Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace itim- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturershouldbecontactedrelativeto any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products’ sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES,ANDINNOEVENT SHALL TYCO FIRE PRODUCTS’ LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHERWARRANTIESEXPRESSOR IMPLIED,INCLUDINGWARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placinganorder,indicatethefull product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: (Specify temperature), Model CHEC Sidewall Sprinkler, P/N (specify). 135°F/57°C . . . . . . . . . . . . . . . P/N 51-396-1-135 155°F/68°C . . . . . . . . . . . . . . . P/N 51-396-1-155 Separately Ordered Cover Plate: Specify: 135°F/57°C Model CHEC Cover Plate Assembly with Specify Finish, P/N (specify). Bright White. . . . . . . . . . . . . . . P/N 56-396-4-135 Chrome . . . . . . . . . . . . . . . . . . P/N 56-396-9-135 Custom . . . . . . . . . . . . . . . . . . P/N 56-396-X-135 Sprinkler Wrench: Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP265 Page 5 of 6 World Fire Protection 41-905 Boardwalk Suite B Palm Desert, CA 92211 760-565-6030 Job Name : DESERT CLUB APARTMENTS Drawing : Location : PALM DESERT Remote Area : 1 Contract : Data File : DESERT APARTMENTS - SOUTH LEVEL 2.WXF Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 1 DESERT CLUB APARTMENTS Date 1/3/2022 HYDRAULIC CALCULATIONS for JOB NAME DESERT CLUB APARTMENTS Location PALM DESERT Drawing # Contract # Date 1/3/2022 DESIGN Remote area #1 Remote area location SOUTH BLDG SECOND FLOOR Occupancy classification RESIDENTIAL Density .05 - Gpm/SqFt Area of application - SqFt Coverage/sprinkler 324 - SqFt Type of sprinkler calculated RESIDENTIAL # Sprinklers calculated 4 In-rack demand - GPM Hose streams 0 - GPM Total water required (including hose streams)68.5565 - GPM @ 47.5938 - Psi Type of system Volume of system (dry or pre-action) - Gal WATER SUPPLY INFORMATION Test date Location Source of info CONTRACTOR INFO World Fire Protection Address 41-905 Boardwalk / Suite B / Palm Desert, CA 92211 Phone #760-565-6030 Name of designer Authority having jurisdiction NOTES: text1(35) - invisible Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 2 DESERT CLUB APARTMENTS Date 1/3/2022 10 20 30 40 E 50 R 60 U 70 S 80 S 90 E 100 R 110 P 120 130 140 150 300 600 900 1200 1500 1800 2100 2400 2700 FLOW ( N ^ 1.85 ) City Water Supply:Demand: C1 C2 C1 - Static Pressure : 94.9 C2 - Residual Pressure: 86.4 C2 - Residual Flow : 2300 D1 - Elevation : 10.394 D2 - System Flow : 68.556 D2 - System Pressure : 47.594 Hose ( Demand ) : _______ D3 - System Demand : 68.556 Safety Margin : 47.293 D1 D2 Water Supply Curve Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 3 DESERT CLUB APARTMENTS Date 1/3/2022 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 C Roll Groove Coupling 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 N * CPVC 90' Ell 0 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O * CPVC Branch Tee 0 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used Summary Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 4 DESERT CLUB APARTMENTS Date 1/3/2022 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SOR 94.9 86.4 2300.0 94.887 68.56 47.594 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1H 21.0 4.9 12.0 16.97 0.05 324 2H 21.0 4.9 12.34 17.21 0.05 324 3H 21.0 4.9 12.06 17.02 0.05 324 4H 21.0 4.9 12.55 17.36 0.05 324 1 22.0 12.48 2 22.0 12.57 3 22.0 12.6 4 22.0 13.12 5 22.0 19.18 6 10.0 29.15 7 10.0 31.05 8 10.0 34.17 TOR 10.0 38.19 BOR 0.5 45.7 UG1 0.5 45.72 SOR -3.0 47.59 Flow Summary - NFPA Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 5 DESERT CLUB APARTMENTS Date 1/3/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1H 21 4.90 16.97 1 N 5.0 8.083 150 12.000 to O 5.0 10.000 -0.433 1 22 16.97 1.101 18.083 0.0502 0.908 Vel = 5.72 0.0 1 16.97 12.475 K Factor = 4.80 2H 21 4.90 17.21 1 N 5.0 3.000 150 12.337 to O 5.0 10.000 -0.433 2 22 17.21 1.101 13.000 0.0515 0.669 Vel = 5.80 0.0 2 17.21 12.573 K Factor = 4.85 3H 21 4.90 17.02 1 N 5.0 9.333 150 12.060 to O 5.0 10.000 -0.433 3 22 17.02 1.101 19.333 0.0504 0.975 Vel = 5.74 0.0 3 17.02 12.602 K Factor = 4.79 4H 21 4.90 17.36 1 N 5.0 9.333 150 12.545 to O 5.0 10.000 -0.433 4 22 17.36 1.101 19.333 0.0523 1.012 Vel = 5.85 0.0 4 17.36 13.124 K Factor = 4.79 1 22 16.97 1.25 6.167 150 12.475 to 0.0 2 22 16.97 1.394 6.167 0.0159 0.098 Vel = 3.57 2 22 17.21 1.25 0.500 150 12.573 to 0.0 3 22 34.18 1.394 0.500 0.0580 0.029 Vel = 7.19 3 22 17.02 1.25 4.250 150 12.602 to 0.0 4 22 51.2 1.394 4.250 0.1228 0.522 Vel = 10.76 4 22 17.36 1.25 N 6.0 22.750 150 13.124 to 6.000 0.0 5 22 68.56 1.394 28.750 0.2106 6.055 Vel = 14.41 0.0 5 68.56 19.179 K Factor = 15.66 5 22 68.56 1.25 2O 12.0 10.667 150 19.179 to 12.000 5.197 6 10 68.56 1.394 22.667 0.2107 4.775 Vel = 14.41 6 10 0.0 1.25 9.000 150 29.151 to 0.0 7 10 68.56 1.394 9.000 0.2106 1.895 Vel = 14.41 7 10 0.0 1.25 9.333 120 31.046 to 0.0 8 10 68.56 1.38 9.333 0.3343 3.120 Vel = 14.71 8 10 0.0 1.5 L 2.0 23.500 120 34.166 to 2.000 0.0 TOR 10 68.56 1.61 25.500 0.1578 4.024 Vel = 10.80 0.0 TOR 68.56 38.190 K Factor = 11.09 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 World Fire Protection Page 6 DESERT CLUB APARTMENTS Date 1/3/2022 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf TOR 10 68.56 1.5 L 2.0 9.500 120 38.190 to S 9.0 12.000 4.114 BOR .500 68.56 1.61 C 1.0 21.500 0.1578 3.393 Vel = 10.80 BOR .500 0.0 4 L 9.559 8.000 150 45.697 to 9.559 0.0 UG1 .500 68.56 4.07 17.559 0.0011 0.020 Vel = 1.69 0.0 UG1 68.56 45.717 K Factor = 10.14 UG1 .500 68.56 4 8F 50.983 179.000 150 45.717 to 2L 19.119 137.016 1.516 SOR -3 68.56 4.07 T 31.864 316.016 0.0011 0.361 Vel = 1.69 S 35.051 0.0 SOR 68.56 47.594 K Factor = 9.94 Final Calculations : Hazen-Williams Computer Programs by Hydratec Inc. Revision: 50.5520.727 Half Pipe Strap Hanger No. 19W (2" Max.) All Pipe HANGER NO. 14W Wood Screw #18 x 1 1/2" Nearest Inch Swivel Ring Sammy Screew Thread Offset Pipe Hanger AND ROD "TJI" Joist 3/8" "A " Wood Screw #18 x 1 1/2" Rod 3" f o r O t h e r s Pre-Drill Hole Wood Joist, Beam or Deck Wood Screw #12 x 1 1/4" Nearest Inch Pipe Wood Joist, Beam or Deck Side Sammy Screew Pipe Thread Wood Joist, Beam or Deck Pipe Strap Rod Note on Plan: Hanger Number and 'A' Dimension Pipe Strap Pipe Strap (Short) Hanger No. 09W Wood Joist or Beam Pipe Strap Note on Plan: Hanger Number and 'A' Dimension 1 1 / 2 " f o r N a i l e r s Hanger No. 18W Pipe HANGER NO. 15W Pipe Pipe Offset Pipe Hanger Hanger No. 17W Half Strap Round to SAMMY SCREW All Swivel Ring Round to SIDE SAMMY SCREW "A " Wood Screw #18 x 1 1/2" SOR UG1 SOR Steel I-Beam or "A " Hanger No. 01S Note on Plan: Hanger Number and "A" Dimension All Top Beam C-Clamp or Equal with Lock Nut Rod Model 300 Michigan Thread Nearest Inch Rounded to Top Beam C-Clamp or Equal Hanger No. 02S Inverted Top Beam C-Clamp (Beam) Note on Plan: Hanger Number and "A" Dimension Nearest Inch Bar Joist Pipe Rounded to Steel I-Beam or with Lock Nut Pipe Rod Top Beam C-Clamp Swivel Ring Thread Swivel Ring "A " Model 300 Michigan All Bar Joist 2 3 7 1 5 6 4 CEILING LEGEND 24" Max. FLEX. COUPLING FLOW SWITCH FLEX. COUPLING 1" TEST AND DRAIN 1.5" CHECK VALVE 1.5" BUTTERFLY VALVE w/ TAMPER (1/8" = 1'-0) 0 4 8 12 1 NO R T H 1 1 11 3 3 3 3 3 3 3 3 555 5 6 6 6 3333 7 77 7 A A R AAR R R SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CMSD/CM SD/CM SD/CM SD/CM SD/CM Half Pipe Strap Hanger No. 19W (2" Max.) All Pipe HANGER NO. 14W Wood Screw #18 x 1 1/2" Nearest Inch Swivel Ring Sammy Screew Thread Offset Pipe Hanger AND ROD "TJI" Joist 3/8" "A " Wood Screw #18 x 1 1/2" Rod 3" f o r O t h e r s Pre-Drill Hole Wood Joist, Beam or Deck Wood Screw #12 x 1 1/4" Nearest Inch Pipe Wood Joist, Beam or Deck Side Sammy Screew Pipe Thread Wood Joist, Beam or Deck Pipe Strap Rod Note on Plan: Hanger Number and 'A' Dimension Pipe Strap Pipe Strap (Short) Hanger No. 09W Wood Joist or Beam Pipe Strap Note on Plan: Hanger Number and 'A' Dimension 1 1 / 2 " f o r N a i l e r s Hanger No. 18W Pipe HANGER NO. 15W Pipe Pipe Offset Pipe Hanger Hanger No. 17W Half Strap Round to SAMMY SCREW All Swivel Ring Round to SIDE SAMMY SCREW "A " Wood Screw #18 x 1 1/2" Steel I-Beam or "A " Hanger No. 01S Note on Plan: Hanger Number and "A" Dimension All Top Beam C-Clamp or Equal with Lock Nut Rod Model 300 Michigan Thread Nearest Inch Rounded to Top Beam C-Clamp or Equal Hanger No. 02S Inverted Top Beam C-Clamp (Beam) Note on Plan: Hanger Number and "A" Dimension Nearest Inch Bar Joist Pipe Rounded to Steel I-Beam or with Lock Nut Pipe Rod Top Beam C-Clamp Swivel Ring Thread Swivel Ring "A " Model 300 Michigan All Bar Joist 1 1 1 1 33 335555 3 3 3 3 7 7 77 R A A A R A R R SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CM SD/CMSD/CM SD/CM SD/CM SD/CM SD/CM SD/CM B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " 1 1 1 1 111 1 1 12 12 4 4 2 3 7 1 5 6 4 CEILING LEGEND DESCRIPTION TOTAL HOSE STREAMS GPM / Ft² for PSI GPM DENSITY DESIGN AREA REDUCTION K= OCCUPANCY CLASS TOTAL HEADS FLOWING MARGIN OF SAFETY PSI BASE OF RISER SYSTEM DEMAND: HYDRAULIC CALCULATION PSI STANDARD Ft² RESPONSE GPM @ TOTAL SYSTEM DEMAND: MAX. COVERAGE per HEAD Ft² GPM @ (1/8" = 1'-0) 0 4 8 12 1 18"=1'-0" SOUTH BLDG. SECOND FLOOR 18"=1'-0" SOUTH BLDG. FIRST FLOOR NO R T H 1 1 1 1 3 3 3 3 3 3 3 3 5 555 3 33 3 7 77 7 R R A R A RA A SD/CM SD/CM SD/CM SD/CM SD/CM SD/CMSD/CM SD/CM SD/CM SD/CM SD/CM SD/CMSD/CMSD/CM SD/CM SD/CM Half Pipe Strap Hanger No. 19W (2" Max.) All Pipe HANGER NO. 14W Wood Screw #18 x 1 1/2" Nearest Inch Swivel Ring Sammy Screew Thread Offset Pipe Hanger AND ROD "TJI" Joist 3/8" "A " Wood Screw #18 x 1 1/2" Rod 3" f o r O t h e r s Pre-Drill Hole Wood Joist, Beam or Deck Wood Screw #12 x 1 1/4" Nearest Inch Pipe Wood Joist, Beam or Deck Side Sammy Screew Pipe Thread Wood Joist, Beam or Deck Pipe Strap Rod Note on Plan: Hanger Number and 'A' Dimension Pipe Strap Pipe Strap (Short) Hanger No. 09W Wood Joist or Beam Pipe Strap Note on Plan: Hanger Number and 'A' Dimension 1 1 / 2 " f o r N a i l e r s Hanger No. 18W Pipe HANGER NO. 15W Pipe Pipe Offset Pipe Hanger Hanger No. 17W Half Strap Round to SAMMY SCREW All Swivel Ring Round to SIDE SAMMY SCREW "A " Wood Screw #18 x 1 1/2" Steel I-Beam or "A " Hanger No. 01S Note on Plan: Hanger Number and "A" Dimension All Top Beam C-Clamp or Equal with Lock Nut Rod Model 300 Michigan Thread Nearest Inch Rounded to Top Beam C-Clamp or Equal Hanger No. 02S Inverted Top Beam C-Clamp (Beam) Note on Plan: Hanger Number and "A" Dimension Nearest Inch Bar Joist Pipe Rounded to Steel I-Beam or with Lock Nut Pipe Rod Top Beam C-Clamp Swivel Ring Thread Swivel Ring "A " Model 300 Michigan All Bar Joist 1 1 11 33 335555 33 3 3 7 7 77 R A A AA R R R SD/CM SD/CM SD/CM SD/CMSD/CM SD/CMSD/CM SD/CM SD/CM SD/CMSD/CM SD/CMSD/CM SD/CM SD/CM SD/CM B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " B. O . B : 8 ' - 0 " 111 111 1 1 1 12 4 412 F.F. 0" 2ND T.O.PL'T. 11'-8|" T.O. 2ND F.F. 20'-9" 9'-1" 1ST T.O.PL'T. F.G. -8" 2 3 7 1 5 6 4 CEILING LEGEND DESCRIPTION TOTAL HOSE STREAMS GPM / Ft² for PSI GPM DENSITY DESIGN AREA REDUCTION K= OCCUPANCY CLASS TOTAL HEADS FLOWING MARGIN OF SAFETY PSI BASE OF RISER SYSTEM DEMAND: HYDRAULIC CALCULATION PSI STANDARD Ft² RESPONSE GPM @ TOTAL SYSTEM DEMAND: MAX. COVERAGE per HEAD Ft² GPM @ (1/8" = 1'-0) 0 4 8 12 1 NO R T H 18"=1'-0" NORTH BLDG. SECOND FLOOR 18"=1'-0" NORTH BLDG. FIRST FLOOR APPROVAL Riverside County Fire Department Office of the Fire Marshal By: The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department. PERMIT # - Chris Cox Fire Safety Supervisor FSS2023-0001