Cantera at Coral Mountain TR 31249 BCPR2021-0030 (Plans 1-4) Solar PlansPLAN SNAPSHOT REPORT BCPR2021-0030
FOR CITY OF LA QUINTA
Building Construction Plan Review 09/16/2021App Date:Plan No.:Plan Type:BCPR2021-0030
City of La QuintaBuilding Construction Plan Review 06/29/2024Exp Date:District:Work Class:
0.00Expired NOT COMPLETEDCompleted:Square Feet:Status:
Description:
Valuation:
CANTERA / SOLAR MASTER PLANS - 2019 CODE CYCLE
10/25/2021 3:19:53 PM (JAKE FUSON)
CANTERA / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 3, & 4 FOR THE 2019 CODE
CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING
CODES.
PLAN 1, 2 & 3: 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS
W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF]
PLAN 4: 6.3kW SOLAR ARRAY - (18) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF]
3/24/2022 10:44:11 AM (JAKE FUSON)
REVISION 1 - ROOF MATERIALS CHANGED TO S-TILE FOR ALL ROOFS.
8/25/2022 2:03:54 PM (JAKE FUSON)
REVISION 2 - UPDATED ROOF OPTIONS FOR PLAN 3.
8/25/2022 2:09:05 PM (JAKE FUSON)
REVISION 3 - UPDATED ROOF LAYOUTS FOR LOTS 43 & 49 + UPDATED ROOF LAYOUT AND
SINGLE LINE DIAGRAM FOR LOT 6 WHERE AN ADDITIONAL PANEL WAS ADDED TO BRING THE
SYSTEM SIZE TO 5.6kW (16 PANELS).
2/16/2023 9:35:52 AM (JAKE FUSON)
REVISION 4 - ADDED ROOF LAYOUT FOR PLAN 1 ELEV. C.
7/12/2023 12:54:43 PM (AJ ORTEGA)
REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS.
PLAN 1, 2 & 3: 5.67kW SOLAR ARRAY - (14) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS
MICROINVERTERS.
PLAN 4: 6.48kW SOLAR ARRAY - (16) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS
MICROINVERTERS.
REVISION 6: PROVIDED SITE SPECIFIC ROOF LAYOUT FOR LOT 63.
$0.00 Assigned To:Approval
Expire Date:06/29/2024
Parcel:Main766070010 Address:Cantera At Coral Mountain Solar
Master Plan
Main Zone:
Contractor
Amy Clemans
1414 HARBOUR WAY S SUITE
1901 RICHMOND, CA 94804
Plan Custom Fields
Tract / Subdivision
Name
CANTERA - PV SYSTEM Tract Number 31249 Model/Series Name
Number of Plan Types SOLARX4 Code Edition 2019 Is this a revision?No
Zoning RL General Plan LDR, ROW City Limits Within La Quinta City
Limits
Acreage 4.3 Subdivision Name TR 31249 Lot Number J
Legal Description Lot J MB 411/23 TR 31249 Centerlines 96874, 96871, 92155,
96872, 92156, 96875,
96869, 96870, 96876,
96873
Page 1 of 378-495 Calle TampicoJune 18, 2025
PLAN SNAPSHOT REPORT (BCPR2021-0030)
Lot Size 25349.7
Attachment File Name Added On Added By Attachment Group Notes
BCPR2021-0030 - TAKEOFF SHEETS
(405W PANELS ONLY).pdf
09/19/2023 10:56 Ortega, AJ Internal Only TAKEOFF SHEETS (405W PANELS ONLY)
BCPR2021-0030 - TAKEOFF
SHEETS.docx
09/19/2023 10:56 Ortega, AJ TAKEOFF SHEETS (DOC FILE)
BCPR2021-0030 - TAKEOFF
SHEETS.pdf
09/19/2023 10:56 Ortega, AJ Internal Only TAKEOFF SHEETS
Construction Plan
Set-2023-09-19-A1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Master Plan
Construction Plan
Set-2023-09-19-B1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Revision 1
Construction Plan
Set-2023-09-19-C1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Revision 2
Construction Plan
Set-2023-09-19-D1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Revision 3
Construction Plan
Set-2023-09-19-E1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Revision 4
Construction Plan
Set-2023-09-19-F1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Construction Plan Set - Revision 5
Revision
Narrative-2023-09-19-G1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Revision Narrative
Revision
Narrative-2023-09-19-H1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Revision Narrative
Revision
Narrative-2023-09-19-I1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Revision Narrative
Revision
Narrative-2023-09-19-J1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Revision Narrative
Revision
Narrative-2023-09-19-K1_v1.pdf
09/19/2023 10:58 Ortega, AJ Available Online Revision Narrative
C002295 - MPermit 405 - Response
Letter.pdf
09/19/2023 11:33 Clemans, Amy Uploaded via City of La Quinta
C002295 - MPermit 405.pdf 09/19/2023 11:33 Clemans, Amy Uploaded via City of La Quinta
C002295 - MPermit 405 - Response
Letter.pdf
09/19/2023 11:36 Clemans, Amy Uploaded via City of La Quinta
C002295 - MPermit 405.pdf 09/19/2023 11:36 Clemans, Amy Uploaded via City of La Quinta
Construction Plan
Set-2023-09-22-K1_v1.pdf
11/20/2023 10:47 Ortega, AJ Available Online Construction Plan Set - Revision 6
Revision
Narrative-2023-09-22-J1_v1.pdf
11/20/2023 10:47 Ortega, AJ Available Online Revision Narrative
Created ByNote Date and Time Created
1.AJ OrtegaThis is an archived record, do not use for 2022 Code Update -
Applicant to submit new BCPR.
04/26/2024 9:17
Invoice No.Amount PaidFeeFee Amount
INV-00002526 $131.25 Hourly Charge - City Building Staff $131.25
$175.00 Hourly Charge - City Building Staff $175.00
$3.28 Credit Card Convenience Fee $3.28
$4.38 Credit Card Convenience Fee $4.38
$313.91 $313.91 Total for Invoice INV-00002526
Grand Total for Plan $313.91 $313.91
UserActivity Number Name Created OnActivity Type Workflow Action Name
Email ACT-000027-2023 AJ Ortega 11/20/2023
Comments: Emailed Applicant (Jared.Nast@sunpower.com; Cc: Amy.Clemans@sunpower.com) Revision 6 is Approved.
Page 2 of 378-495 Calle TampicoJune 18, 2025
PLAN SNAPSHOT REPORT (BCPR2021-0030)
Submittal Name Status Received Date Due Date Complete Date Resubmit Completed
ApprovedBuilding Revision Review v.1 09/25/2023 10/02/2023 11/20/2023 No Yes
Completed
Date
Due
Date
Assigned
DateStatusAssigned UserDepartmentItem Review Name
Building (1WK)Building Ortega, AJ Approved 09/25/2023 10/02/2023 11/20/2023
Comments: REVISION 6 ONLY
Workflow Step / Action Name Action Type Start Date End Date
Plan Check v.1 11/20/2023 10:47
Building Revision Review v.1 Receive Submittal 09/25/2023 0:00 11/20/2023 10:47
Linked Records v.1
Linked Permits v.1 Create Sub Permit
Page 3 of 378-495 Calle TampicoJune 18, 2025
BCPR2021-0030 – CANTERA MASTER SOLAR PLAN TAKE-
OFFS
PLAN 1, 2 & 3
Permit Notes:
PLAN 1, 2 & 3: 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF] REFERENCE BCPR2021-0030
FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES.
Fee Breakdown:
- Building Standards Administration (BSAS)
- Electrical 2019
o PV System less than 10kW PC
o PV System less than 10kW
o (1) Miscellaneous Electrical
- Permit issuance
- Records Management Fee
- Technology Enhancement Fee
PLAN 4
Permit Notes:
PLAN 4: 6.3kW SOLAR ARRAY - (18) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF] REFERENCE BCPR2021-0030
FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES.
Fee Breakdown:
- Building Standards Administration (BSAS)
- Electrical 2019
o PV System less than 10kW PC
o PV System less than 10kW
o (1) Miscellaneous Electrical
- Permit issuance
- Records Management Fee
- Technology Enhancement Fee
405W PANEL SYSTEMS ONLY
BCPR2021-0030
CANTERA MASTER SOLAR PLAN TAKE-OFFS
PLAN 1, 2 & 3
Permit Notes:
5.67kW SOLAR ARRAY - (14) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS MICROINVERTERS
AND 100A PV LOAD CENTER [294SF] REFERENCE BCPR2021-0030 FOR APPROVED MASTER
PLANS. 2019 CALIFORNIA BUILDING CODES.
Fee Breakdown:
- Building Standards Administration (BSAS)
- Electrical 2019
o PV System less than 10kW PC
o PV System less than 10kW
o No Miscellaneous Electrical
- Permit issuance
- Records Management Fee
- Technology Enhancement Fee
PLAN 4
Permit Notes:
6.48kW SOLAR ARRAY - (16) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS MICROINVERTERS
AND 100A PV LOAD CENTER [336SF] REFERENCE BCPR2021-0030 FOR APPROVED MASTER
PLANS. 2019 CALIFORNIA BUILDING CODES.
Fee Breakdown:
- Building Standards Administration (BSAS)
- Electrical 2019
o PV System less than 10kW PC
o PV System less than 10kW
o No Miscellaneous Electrical
- Permit issuance
- Records Management Fee
- Technology Enhancement Fee
CANTERA / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLANS 1, 2, 3, & 4 FOR THE 2019 CODE
CYCLE. INDIVIDUAL SOLAR PERMITS TO BE ISSUED FOR EACH LOT. 2019 CALIFORNIA BUILDING
CODES.
PLAN 1, 2 & 3: 5.25kW SOLAR ARRAY - (15) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [300SF]
PLAN 4: 6.3kW SOLAR ARRAY - (18) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF]
REVISION 1 - ROOF MATERIALS CHANGED TO S-TILE FOR ALL ROOFS.
REVISION 2 - UPDATED ROOF OPTIONS FOR PLAN 3.
REVISION 3 - UPDATED ROOF LAYOUTS FOR LOTS 43 & 49 + UPDATED ROOF LAYOUT AND
SINGLE LINE DIAGRAM FOR LOT 6 WHERE AN ADDITIONAL PANEL WAS ADDED TO BRING THE
SYSTEM SIZE TO 5.6kW (16 PANELS).
REVISION 4 - ADDED ROOF LAYOUT FOR PLAN 1 ELEV. C.
REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS.
PLAN 1, 2 & 3: 5.67kW SOLAR ARRAY - (14) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS
MICROINVERTERS.
PLAN 4: 6.48kW SOLAR ARRAY - (16) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS
MICROINVERTERS.
2/8/2022
BUILDING AND SAFETY DEPARTMENT
City LaQuinta
RE: RESUBMITAL LETTER
Project Name:Cantera
Project Address:
Project Description:Roof top photovoltaic system Master Permit Package
Sheet No.
PVA-1 TO PVA-4
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
Elen C. Dimaalihan / Design Engineer
elen.culla@sunpower.com
LaQuinta CA 92210
Change No.Description of Change
1 Updated to S-tile for all roofs
5/31/2022
BUILDING AND SAFETY DEPARTMENT
City of LaQuinta
RE: RESUBMITAL LETTER
Project Name:Cantera
Project Address:
Project Description:Roof top photovoltaic system IPermit Package for Cantera
Sheet No.
PVA-3.2
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
Elen C. Dimaalihan / Design Engineer
elen.culla@sunpower.com
LaQuinta, CA 92210
Change No.Description of Change
1 Updated to show options
12/28/2022
BUILDING AND SAFETY DEPARTMENT
City of La Quinta
RE: RESUBMITAL LETTER
Project Name:
Project Address:
Project Description:Roof top photovoltaic system Individual Permit Package Cantera
Sheet No.
PVA-1
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
Elen C. Dimaalihan / Design Engineer
elen.culla@sunpower.com
Replaced layouts 5 & 6 for Plan 1/C with the attached redline.
Cantera
LaQuinta, CA 92253
Change No.Description of Change
6
3/5/2023
BUILDING AND SAFETY DEPARTMENT
City of LaQuinta
RE: RESUBMITAL LETTER
Plan Check Number/Permit Number:
Project Name:
Project Address:
Project Description:Rooftop Photovoltaic System Master Plan Permit Package for Cantera
Sheet No.
ALL
Should you have any additional questions, feel free to contact me.
Sincerely,
Elen C. Dimaalihan / Design Engineer
elen.culla@sunpower.com
7 CHANGED TO 405W HANWA QCELLS MODULES & UPDATED Kw
Change No. Description of Change
Cantera
Laquinta, California 92253
9/11/2023
BUILDING AND SAFETY DEPARTMENT
City of La Quinta
RE: PLAN CHECK RESPONSE
Plan Check Number/Permit Number:
Project Name:Cantera
Project Address:Laquinta, California 92253
This is in response to the plan check comments dated 09/11/2023 for the project noted above.
Sheet No.
PVA-4, PVE-1.4
& PVE-1.5
Please do note that this response letter is applicable to all plan types.
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
John Mark Singh / Design Engineer
JohnMark.Singh@sunpowercorp.com
Comment No.Comments Response
Project Description:Rooftop Photovoltaic System Master Plan Permit Package for Cantera
Added Custom Layout Used for Lot 63 &
Corrected Wire & Breaker Size on SLD for 16
Modules
6 Include Custom Layout for Lot 63
6/28/2022
BUILDING AND SAFETY DEPARTMENT
City of LaQuinta
RE: RESUBMITAL LETTER
Project Name:Cantera
Project Address:
Project Description:Roof top photovoltaic system Master Plan Permit Package for Cantera
Sheet No.
PVA-1, PVA-3
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
Elen C. Dimaalihan / Design Engineer
elen.culla@sunpower.com
4 Removed previous layout and added customized layout used in Lot 43 and 49
LaQuinta, CA 92210
Change No.Description of Change
PVA-1.15 Added custom layout for model lot 6 CFI compliance
9/11/2023
BUILDING AND SAFETY DEPARTMENT
City of La Quinta
RE: PLAN CHECK RESPONSE
Plan Check Number/Permit Number:
Project Name:Cantera
Project Address:Laquinta, California 92253
This is in response to the plan check comments dated 09/11/2023 for the project noted above.
Sheet No.
PVA-4, PVE-1.4
& PVE-1.5
Please do note that this response letter is applicable to all plan types.
Should you have any additional questions, feel free to contact me.
Sincerely,
_____________________________
John Mark Singh / Design Engineer
JohnMark.Singh@sunpowercorp.com
Comment No.Comments Response
Project Description:Rooftop Photovoltaic System Master Plan Permit Package for Cantera
Added Custom Layout Used for Lot 63 &
Corrected Wire & Breaker Size on SLD for 16
Modules
6 Include Custom Layout for Lot 63
SOLAR MASTER PLAN PERMIT PACKAGE
BEAZER HOMES - SOUTHERN CALIFORNIA
310 COMMERCE STE 150IRVINE, CA 92602
LA QUINTA, CALIFORNIA 92210
CANTERA
PLAN 1, 2, 3, 4
CODE INFORMATION
APPLICABLE CODES, LAWS AND REGULATIONS
2019 CALIFORNIA RESIDENTIAL CODE (CRC)
2019 CALIFORNIA BUILDING CODE (CBC)
2019 CALIFORNIA FIRE CODE (CFC)
2019 CALIFORNIA ELECTRICAL CODE (CEC)
2019 CALIFORNIA MECHANICAL CODE (CMC)
2019 CALIFORNIA PLUMBING CODE (CPC)
2019 GREEN BUILDING CODE
2019 LA QUINTA MUNICIPAL CODE
NOT TO SCALE
SHEET
GENERAL NOTES: SHEET INDEX
VICINITY MAP
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
PROJECT LOCATION
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
PVA-0
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
A
-
0
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
1
1
,
2
0
2
1
-
6
:
3
9
p
m
SOLAR ARCHITECTURAL DRAWINGS
SOLAR STRUCTURAL DRAWINGS
PL
A
N
1
,
2
,
3
,
4
MOUNTING DETAILS, STRUCTURAL INFORMATION &
SPECIFICATIONS
PVS-1
PVS-2 STRUCTURAL CALCULATIONS
SOLAR ELECTRICAL DRAWINGS
PVE-1.1 ELECTRICAL SINGLE LINE DIAGRAM
PVE-2 ELECTRICAL DETAILS
PVE-3 ELECTRICAL DATA & SPECIFICATIONS
PVE-1.2 ELECTRICAL SINGLE LINE DIAGRAM
PVE-1.3 ELECTRICAL SINGLE LINE DIAGRAM
PVE-1.4 ELECTRICAL SINGLE LINE DIAGRAM
PVE-1.5 ELECTRICAL SINGLE LINE DIAGRAM
PVE-1.6 ELECTRICAL SINGLE LINE DIAGRAM
COVER PAGEPV0-1
PVA-1
PVA-2
PVA-3
PVA-4
PLAN 1 ELEVATION A,B,C
PLAN 2 ELEVATION A,B,C
PLAN 3 ELEVATION A,B,C
PLAN 4 ELEVATION A,B,C
BCPR2021-0030
CANTERA / SOLAR PHOTOVOLTAIC MASTER
PLANS FOR PLANS 1, 2, 3, & 4 FOR THE 2019
CODE CYCLE. INDIVIDUAL SOLAR PERMITS
TO BE ISSUED FOR EACH LOT. 2019
CALIFORNIA BUILDING CODES.
PLAN 1, 2 & 3: 5.25kW SOLAR ARRAY - (15)
350W SUNPOWER SPR-X21-350-BLK-E-AC
PANELS W/ INTEGRATED MICROINVERTERS
+ 100A PV LOAD CENTER [300SF]
PLAN 4: 6.3kW SOLAR ARRAY - (18) 350W
SUNPOWER SPR-X21-350-BLK-E-AC PANELS
W/ INTEGRATED MICROINVERTERS + 100A
PV LOAD CENTER [360SF]
12/09/2021
LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2
PLAN 1 - ELEVATION A - S- TILE
PLAN 1 - ELEVATION B - S- TILE
PLAN 1 - ELEVATION C - FLAT TILE
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 150° - 180°LAYOUT 3 FRONT OF HOUSE : 330° - 0°LAYOUT 4 LAYOUT 5
NOTE :
ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO
SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY.
BASE SQUARE FOOTAGE: 2,179 SQ. FT.
SUNPOWER 96 CELLS AC MODULES QUANTITY: 15
MODEL NO.NOMINAL POWER (Pnom)
335W
SYSTEM SIZE
5.03 kW
350W 5.25 kWSPR-350
SPR-335
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINTROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX (TYP.)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
SEE PVE 1.1 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
FRONT OF HOUSE (FOH)
FRONT OF HOUSE : 240° - 270°
SEE PVE 1.1 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
ROOF ACCESS POINT
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TRANSITION BOX
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
(N) LOAD CENTER (INSIDE GARAGE)
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
TRANSITION BOX
ROOF ACCESS POINT
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
SHEET
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
PVA-1
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
A
-
1
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
1
1
,
2
0
2
1
-
4
:
5
9
p
m
PL
A
N
1
E
L
E
V
A
T
I
O
N
A
,
B
,
C
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
SCALE 3/32" - 1'-0"
12/09/2021
LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2
PLAN 2 - ELEVATION A - S- TILE
PLAN 2 - ELEVATION B - S- TILE
PLAN 2 - ELEVATION C - FLAT TILE
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5
NOTE :
ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO
SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY.
BASE SQUARE FOOTAGE: 2,333 SQ. FT.
SUNPOWER 96 CELLS AC MODULES QUANTITY: 15
MODEL NO.NOMINAL POWER (Pnom)
335W
SYSTEM SIZE
5.03 kW
350W 5.25 kWSPR-350
SPR-335
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
ROOF ACCESS POINT
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
TRANSITION BOX
TRANSITION BOX
FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)
TRANSITION BOX TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
ROOF ACCESS POINT ROOF ACCESS POINT
SEE PVE 1.2 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.2 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TRANSITION BOX (TYP.)
TRANSITION BOX (TYP.)
ROOF ACCESS POINT
SEE PVE 1.2 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
FRONT OF HOUSE (FOH)
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TRANSITION BOX
ROOF ACCESS POINT
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TRANSITION BOX
ROOF ACCESS POINT
SEE PVE 1.2 FOR ELECTRICAL
SINGLE DIAGRAM
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TRANSITION BOX (TYP.)
SHEET
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
PVA-2
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
A
-
2
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
1
1
,
2
0
2
1
-
4
:
5
9
p
m
PL
A
N
2
E
L
E
V
A
T
I
O
N
A
,
B
,
C
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
SCALE 3/32" - 1'-0"
12/09/2021
LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2
PLAN 3 - ELEVATION A - S- TILE
PLAN 3 - ELEVATION B - S- TILE
PLAN 3 - ELEVATION C - FLAT TILE
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3
NOTE :
ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO
SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY.
BASE SQUARE FOOTAGE: 2,670 SQ. FT.
SUNPOWER 96 CELLS AC MODULES QUANTITY: 15
MODEL NO.NOMINAL POWER (Pnom)
335W
SYSTEM SIZE
5.03 kW
350W 5.25 kWSPR-350
SPR-335
FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
FRONT OF HOUSE (FOH)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAMTO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX
SHEET
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
PVA-3
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
A
-
3
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
1
1
,
2
0
2
1
-
4
:
5
8
p
m
PL
A
N
3
E
L
E
V
A
T
I
O
N
A
,
B
,
C
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
SCALE 3/32" - 1'-0"
12/09/2021
LEGEND: ARE 3' WIDE FIRE ACCESS PATH PLAN TYPE OPTION DESCRIPTION
01
02
03
-----------------------------------
-----------------------------------
-----------------------------------
04
05
-----------------------------------
-----------------------------------
FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2
PLAN 4 - ELEVATION A - S- TILE
PLAN 4 - ELEVATION B - S- TILE
PLAN 4 - ELEVATION C - FLAT TILE
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5
FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5
NOTE :
ROOFTOP PENETRATIONS AND/OR OBSTRUCTIONS NOT PERTAINING TO
SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER THE ARRAY.
BASE SQUARE FOOTAGE: 3,006 SQ. FT.
SUNPOWER 96 CELLS AC MODULES QUANTITY: 18
MODEL NO.NOMINAL POWER (Pnom)
335W
SYSTEM SIZE
6.03 kW
350W 6.30 kWSPR-350
SPR-335
FRONT OF HOUSE (FOH)
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT
ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.5 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.3 FOR ELECTRICAL
SINGLE DIAGRAM
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.6 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX (TYP.)
TRANSITION BOX
TRANSITION BOX
TRANSITION BOX
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.4 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.5 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
FRONT OF HOUSE (FOH)
TO ELECTRIC
UTILITY GRID
(E) SERVICE POINT AND
UTILITY METERING
UTILITY AC DISCONNECT SWITCH
(OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
(N) LOAD CENTER (INSIDE GARAGE)
SEE PVE 1.6 FOR ELECTRICAL
SINGLE DIAGRAM
ROOF ACCESS POINT
ROOF ACCESS POINT
TRANSITION BOX (TYP.)
SHEET
SO
L
A
R
M
A
S
T
E
R
P
L
A
N
P
E
R
M
I
T
P
A
C
K
A
G
E
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
PVA-4
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
A
-
4
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
1
1
,
2
0
2
1
-
4
:
5
8
p
m
PL
A
N
4
E
L
E
V
A
T
I
O
N
A
,
B
,
C
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
SCALE 3/32" - 1'-0"
12/09/2021
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
S
-
2
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
0
9
,
2
0
2
1
-
6
:
1
1
p
m
PVS-1
12/09/2021
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT
DATE DRAWN
OPPORTUNITY
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
S
-
2
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
0
9
,
2
0
2
1
-
6
:
1
1
p
m
PVS-2
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 5.25 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
25A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 10
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 13.10 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 16.38 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.59 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.69%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 16.38 A
NEXT LARGER OCPD SIZE 20 A
ROOF JCT BOX TO PV LOAD CENTER #10
NUMBER OF MODULES PER BRANCH CIRCUIT 5
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 6.55 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 8.19 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 11.29 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.61%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 8.19 A
NEXT LARGER OCPD SIZE 20 A
#10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 19.65 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 24.56 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 23.96 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.20%
OVERCURRENT PROTECTION 25A, 2P
MINIMUM OCPD = IOUT x 1.25 24.56 A
NEXT LARGER OCPD SIZE 25 A
VOLTAGE DROP AT 51 FT DISTANCE VOLTAGE DROP AT 90 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
5 AC MODULESBRANCH CIRCUIT #2
10 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.1
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
ROOF JCT BOX TO PV LOAD CENTER PV LOAD CENTER TO GRID-TIE WIRING
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 5.25 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
25A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
ROOF JCT BOX TO PV LOAD CENTER #10
NUMBER OF MODULES PER BRANCH CIRCUIT 9
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 11.79 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 14.74 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 20.33 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.78%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 14.74 A
NEXT LARGER OCPD SIZE 20 A
ROOF JCT BOX TO PV LOAD CENTER #10
NUMBER OF MODULES PER BRANCH CIRCUIT 6
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 7.86 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 9.83 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 13.55 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.38%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 9.83 A
NEXT LARGER OCPD SIZE 20 A
PV LOAD CENTER TO GRID-TIE WIRING #10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 19.65 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 24.56 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 23.96 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.20%
OVERCURRENT PROTECTION 25A, 2P
MINIMUM OCPD = IOUT x 1.25 24.56 A
NEXT LARGER OCPD SIZE 25 A
VOLTAGE DROP AT 64 FT DISTANCE VOLTAGE DROP AT 47 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
6 AC MODULESBRANCH CIRCUIT #2
9 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.2
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHI F UNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 5.25 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
25A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 8
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 10.48 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.76%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 13.10 A
NEXT LARGER OCPD SIZE 20 A
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 7
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 9.17 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 11.46 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 15.81 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.89%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 11.46 A
NEXT LARGER OCPD SIZE 20 A
#10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 19.65 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 24.56 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 23.96 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.20%
OVERCURRENT PROTECTION 25A, 2P
MINIMUM OCPD = IOUT x 1.25 24.56 A
NEXT LARGER OCPD SIZE 25 A
VOLTAGE DROP AT 70 FT DISTANCE VOLTAGE DROP AT 94 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
7 AC MODULESBRANCH CIRCUIT #2
8 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.3
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
ROOF JCT BOX TO PV LOAD CENTER ROOF JCT BOX TO PV LOAD CENTER
PV LOAD CENTER TO GRID-TIE WIRING
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 6.30 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
30A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 9
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 11.79 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 14.74 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 20.33 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.84%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 14.74 A
NEXT LARGER OCPD SIZE 20 A
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 9
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 11.79 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 14.74 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 20.33 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.84%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 14.74 A
NEXT LARGER OCPD SIZE 20 A
#10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 23.58 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 29.48 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 28.76 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.24%
OVERCURRENT PROTECTION 30A, 2P
MINIMUM OCPD = IOUT x 1.25 29.48 A
NEXT LARGER OCPD SIZE 30 A
VOLTAGE DROP AT 69 FT DISTANCE VOLTAGE DROP AT 69 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
9 AC MODULESBRANCH CIRCUIT #2
9 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.4
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
ROOF JCT BOX TO PV LOAD CENTER ROOF JCT BOX TO PV LOAD CENTER
PV LOAD CENTER TO GRID-TIE WIRING
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 6.30 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
30A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 12
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 15.75 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 19.65 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 27.10 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.97%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 19.65 A
NEXT LARGER OCPD SIZE 20 A
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 6
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 7.86 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 9.83 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 20.33 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.35%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 9.83 A
NEXT LARGER OCPD SIZE 20 A
#10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 23.58 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 29.48 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 28.76 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.24%
OVERCURRENT PROTECTION 30A, 2P
MINIMUM OCPD = IOUT x 1.25 29.48 A
NEXT LARGER OCPD SIZE 30 A
VOLTAGE DROP AT 60 FT DISTANCE VOLTAGE DROP AT 43 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
6 AC MODULESBRANCH CIRCUIT #2
12 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.5
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
ROOF JCT BOX TO PV LOAD CENTER ROOF JCT BOX TO PV LOAD CENTER
PV LOAD CENTER TO GRID-TIE WIRING
12/09/2021
FIGURE A: SINGLE LINE DIAGRAM - 6.30 kWDC
UTILITY
BIDIRECTIONAL
METER
(NOT CENTER-FED)INCOMING SOURCE FEED
H
MCB
(E)MAIN SERVICE PANEL
200A, 120/240V, 1PH, 3W
GND
EXISTING
GND
TO HOUSE
LOADS
BREAKERS SHALL BE
INSTALLED OPPOSITE
END OF THE MAIN
BREAKER
*MSP MAX PV BREAKER (A) =
X 120% -
=200A, 2P
30A, 2P
200A, 2P 200A, 2P
40A, 2P
GND
3
NOTE:
FOR SOLAR PHOTOVOLTAIC ONLY.
NO ADDITIONAL LOADS TO BE APPLIED
(N)LOAD CENTER
100A OR EQUIVALENT, 120/240V, 1PH
20A, 2P
20A, 2P
TAG
1
2
3
4
5
SOURCE CIRCUIT TRANSITION BOX
(N) LOAD CENTER
PV PRODUCTION METER
SEPARATE AC DISCONNECT
DESCRIPTION
SOLAR AC MODULE / BRANCH
3
4
(N) LOAD CENTER
PV PRODUCTION METER AC, BRANCH 1
FIGURE C: ELECTRICAL CALCULATIONS
AC, BRANCH 2 AC, SUB-PANEL
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 10
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 13.10 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 16.38 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 22.59 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.46%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 16.38 A
NEXT LARGER OCPD SIZE 20 A
#10
NUMBER OF MODULES PER BRANCH CIRCUIT 8
VOLTAGE 240 V
BRANCH CURRENT: IOUT = 10.48 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 13.10 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE ADDER 22°C
TEMPERATURE USED FOR AMPACITY DE-RATING 69°C
TEMPERATURE DE-RATING COEFFICIENT 0.58
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 18.07 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30 A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.65%
OVERCURRENT PROTECTION 20A, 2P
MINIMUM OCPD = IOUT x 1.25 13.10 A
NEXT LARGER OCPD SIZE 20 A
#10
VOLTAGE 240 V
SUM OF BRANCHES: IOUT_TOTAL = 23.58 A
MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 29.48 A
CONDUCTOR DE-RATING
MAXIMUM AMBIENT TEMPERATURE 47°C
TEMPERATURE USED FOR AMPACITY DE-RATING 47°C
TEMPERATURE DE-RATING COEFFICIENT 0.82
FILL DE-RATING COEFFICIENT 1
IWIRE_MIN = IOUT / TEMP_COEFF / FILL_COEFF 28.76 A
WIRE SIZE SELECTED BASED ON AMPACITY #10
AMPACITY AT 60C TERMINATION (>IOUT) 30A
CONDUCTOR SIZE PER NEC #10
CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP #10
0.24%
OVERCURRENT PROTECTION 30A, 2P
MINIMUM OCPD = IOUT x 1.25 29.48 A
NEXT LARGER OCPD SIZE 30 A
VOLTAGE DROP AT 34 FT DISTANCE VOLTAGE DROP AT 60 FT DISTANCE
VOLTAGE DROP AT 10 FT DISTANCE
ELECTRICAL NOTES
1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED
TO GROUND AT COUPLINGS ON BOTH ENDS.
2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE
SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT,
SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM
TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT
SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP
ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED.
3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS,
CRIMPS, ETC.
4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII
REQUIREMENTS.
5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW
EQUIPMENTS TO BE INSTALLED.
6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL
UTILITY REQUIREMENTS.
7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.
8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC
RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS.
9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.
10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS
NO OTHER CONDUCTORS RUNNING THROUGH IT.
11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND
INSTALLED BY A THIRD PARTY.
12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY
REQUIRE UPSIZE.
NOTE :
x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED
TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE
FOR CONSTRUCTION FEASIBILITY.
x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE
INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC
CONTRACT WITH SUNPOWER.
x SUNPOWER MONITORING SYSTEM
x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING
ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY
IS NOT REQUIRED.
1
2
CONDUCTOR / CONDUIT SCHEDULE
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
2
1
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
#12 TYPE-ER, PER
BRANCH CIRCUIT --WITH EGCA
B
TAG
SPR-X21-350-BLK-E-AC (240)
EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES
5
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B 3
1
GND
C
C
UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC
#10
#10
OPTIONAL
ETHERNET
CONNECTION TO
DSL/CABLE MODEM
CAT5e
CURRENT
TRANSFORMERS (100A)
INSTALLED ON THE
CUSTOMER SIDE OF
THE PANEL
1#14
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
#22 NMFC
CU-NM-B
AWG TWISTED PAIR
EGC BARE CU
3
INSTALLED IN WALL
CAVITY
1/2"
--
PRODUCTION CURRENT
TRANSFORMERS (100A)
SUNPOWER
MONITORING
PVS6
E
#14
3
D
E
E
D
#6
15A, 2P
2
A
DC
AC
DC
AC
1
SUNPOWER MODULES
AC MODULE
EXTENSION CABLE
NM CABLE OR EQ
INSTALLED IN WALL CAVITY --EGC BARE CU
CU-NM-B
INTEGRATED MICROINVERTER
B
8 AC MODULESBRANCH CIRCUIT #2
10 AC MODULESBRANCH CIRCUIT #1
SPR-X21-350-BLK-E-AC
#10
#10
SPR-X21-350-BLK-E-AC (240)
EL
E
C
T
R
I
C
A
L
S
I
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
&
S
P
E
C
I
F
I
C
A
T
I
O
N
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
PVE-1.6
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
ROOF JCT BOX TO PV LOAD CENTER ROOF JCT BOX TO PV LOAD CENTER
PV LOAD CENTER TO GRID-TIE WIRING
12/09/2021
FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION
FIGURE 1: ELECTRICAL SIGNAGES/STICKERS
SIGNAGE NOTES
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVERCURRENT DEVICE
x
x
x
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUTDOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
RAPID SHUTDOWN SWITCH FOR
SOLAR PV SYSTEM
x
x
x
PHOTOVOLTAIC SYSTEM COMBINER
PANEL: DO NOT ADD LOADS
x
x
x
x
x
x
x
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
AMPS
VOLTS
AMPS
VOLTS
PHOTOVOLTAIC POINT OF
INTERCONNECTION
WARNING: ELECTIC SHOCK HAZARD. DO NOT
TOUCH TERMINALS. TERMINALS ON BOTH THE
LINE AND LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER
PV POWER SOURCE
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
RATED AC OUTPUT CURRENT:
NOMINAL OPERATING AC VOLTAGE:
AMPS
VOLTS
AMPS
VOLTS
PHOTOVOLTAIC POINT OF
INTERCONNECTION
WARNING: ELECTIC SHOCK HAZARD. DO NOT
TOUCH TERMINALS. TERMINALS ON BOTH THE
LINE AND LOAD SIDE MAY BE ENERGIZED
IN THE OPEN POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER
PV POWER SOURCE
MAXIMUM RATED AC OUTPUT CURRENT:
MAXIMUM OPERATING AC VOLTAGE:
( kWDC)
( kWDC)
( kWDC)
( kWDC)
19.65
240
19.65
240
23.58
240
23.58
240
5.25 5.25
5.25
AC SOLAR DISCONNECT
x
TYPICAL DIRECTORY PLACARD
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
DA
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0116477
09-28-2021
ECULLA
09-28-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
08-09-2021
R
E
V
I
S
I
O
N
S
PVE-2
PHOTOVOLTAICARRAY ON ROOF
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
CAUTION:
DRIVEWAY
PHOTOVOLTAICAC DISCONNECT
MAIN SERVICEPANEL
SOLAR LOADCENTER
E
LECT R I C A L
E22659
Exp. 03-31-23R
EGISTERE D P R O F ESSIONAL
E
N
G
I
N
E
ER
S
TATE OF CA L I F O R NIA
CHIFUNG L
E
UN
G
12/09/2021
SOLADECK DATA SHEETCURRENT TRANSFORMER SPECIFICATION SHEET AC DISCONNECT DATA SHEET ROMEX SPECIFICATION SHEET P2/2 PV MODULE SPECIFICATION SHEET PG PVS6 DATASHEET 1
PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 1 PVS6 INSTALLATION INSTRUCTIONS 2 PV MODULE COMPLIANCE LETTER CERTIFICATE OF COMPLIANCE FOR WIRING SYSTEM AND HARNESS
EL
E
C
T
R
I
C
A
L
D
A
T
A
&
S
P
E
C
I
F
I
C
A
T
I
O
N
S
SHEET
RE
V
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
D
B
C
B
R
E
V
I
S
I
O
N
S
NOT TO SCALE
SP
R
-
X
2
1
-
3
5
0
-
B
L
K
-
E
-
A
C
(
2
4
0
)
FI
L
E
:
D
-
0
1
1
4
8
9
8
-
M
P
P
P
-
0
8
0
9
2
0
2
1
-
S
O
L
A
R
-
P
V
E
-
4
.
d
w
g
,
U
S
E
R
:
e
c
u
l
l
a
,
D
A
T
E
/
T
I
M
E
:
A
u
g
0
8
,
2
0
2
1
-
1
1
:
4
3
p
m
1
4
1
4
H
A
R
B
O
U
R
W
A
Y
S
O
U
T
H
R
I
C
H
M
O
N
D
,
C
A
9
4
8
0
4
(5
1
0
)
5
4
0
-
0
5
5
0
TH
I
S
D
O
C
U
M
E
N
T
C
O
N
T
A
I
N
S
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
.
R
E
P
R
O
D
U
C
T
I
O
N
,
DI
S
C
L
O
S
U
R
E
,
O
R
U
S
E
W
I
T
H
O
U
T
S
P
E
C
I
F
I
C
W
R
I
T
T
E
N
A
U
T
H
O
R
I
Z
A
T
I
O
N
O
F
T
H
E
SU
N
P
O
W
E
R
C
O
R
P
O
R
A
T
I
O
N
I
S
S
T
R
I
C
T
L
Y
F
O
R
B
I
D
D
E
N
.
C
O
R
P
O
R
A
T
I
O
N
,
S
Y
S
T
E
M
S
C
A
L
I
C
E
N
S
E
#
:
8
9
0
8
9
5
DRAWN BY
PROJECT NO.
DATE DRAWN
COMMUNITY ID
CHECKED BY
DATE CHECKED
CA
N
T
E
R
A
BE
A
Z
E
R
H
O
M
E
S
-
S
O
U
T
H
E
R
N
C
A
L
I
F
O
R
N
I
A
31
0
C
O
M
M
E
R
C
E
S
T
E
1
5
0
LA
Q
U
I
N
T
A
,
C
A
L
I
F
O
R
N
I
A
9
2
2
1
0
C002295
D-0114898
08-09-2021
ECULLA
08-09-2021
EOR
IR
V
I
N
E
,
C
A
9
2
6
0
2
PVE-3