Loading...
Cantera at Coral Mountain TR 31249 BCPR2021-0030 (Plans 1-4) Solar Plans - Revision 5SOLAR MASTER PLAN PERMIT PACKAGE BEAZER HOMES - SOUTHERN CALIFORNIA 310 COMMERCE, STE 150IRVINE, CA 92602 LAQUINTA, CALIFORNIA 92253 CANTERA PLAN 1 , 2, 3 , 4 5.67 kW, 6.48 kW PHOTOVOLTAIC SYSTEM CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® VICINITY MAP PROJECT LOCATION SHEET SO L A R M A S T E R P L A N P E R M I T P A C K A G E RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-0 GENERAL NOTES: SHEET INDEX SOLAR ARCHITECTURAL DRAWINGS SOLAR STRUCTURAL DRAWINGS SOLAR ELECTRICAL DRAWINGS PVE-1.1 ELECTRICAL SINGLE LINE DIAGRAM PVE-2 ELECTRICAL DETAILS PVE-3 ELECTRICAL DATA & SPECIFICATIONS PVS-1 PVS-2 MOUNTING DETAILS & STRUCTURAL CALCULATIONS PVS-3 TYPICAL ROOF INSET DETAILS MOUNTING DETAILS, STRUCTURAL INFORMATION & SPECIFICATIONS PVA-0 COVER SHEET PVA-1 PLAN 1 ELEVATION A,B,C PVA-2 PVA-3.1 PVA-3.2 PVA-4 PLAN 2 ELEVATION A,B,C PLAN 3 ELEVATION A,B,C PLAN 3 OPT. EXT. COV PATIO ELEVATION A,B,C PLAN 4 ELEVATION A,B,C PVE-4 ELECTRICAL DATA & SPECIFICATIONS PVE-1.2 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.3 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.4 ELECTRICAL SINGLE LINE DIAGRAM PVE-1.5 ELECTRICAL SINGLE LINE DIAGRAM TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. PLAN 1, 2 & 3: 5.67kW SOLAR ARRAY - (14) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS MICROINVERTERS. PLAN 4: 6.48kW SOLAR ARRAY - (16) 405W Q.PEAK DUO PANELS + ENPHASE IQ7HS MICROINVERTERS. BCPR2021-0030 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 1 - ELEVATION A - S- TILE PLAN 1 - ELEVATION B - S- TILE PLAN 1 - ELEVATION C - S- TILE FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 150° - 180°LAYOUT 2 FRONT OF HOUSE : 330° - 90°LAYOUT 3 FRONT OF HOUSE : 240° - 270°LAYOUT 4 NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2,179 SQ. FT. SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.2 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.2 SLD REFERENCE PVE-1.2 SUNPOWER 132 CELLS AC MODULES QUANTITY: 14 MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE 5.67 kWQ.PEAK DUO BLK ML-G10+ (405) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) TO ELECTRIC UTILITY GRID TO ELECTRIC UTILITY GRID (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.)TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) FRONT OF HOUSE : 330° - 0°LAYOUT 3 SLD REFERENCE PVE-1.2 (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S U I T E 1 5 0 LA Q U I N T A , C A 9 2 2 5 3 IR V I N E C A 9 2 6 0 2 , U N I T E D S T A T E S SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125291 2/22/23 JOHN PAUL LINOGAO TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-1 PL A N 1 E L E V A T I O N A , B , A N D C 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 2 - ELEVATION A - S- TILE PLAN 2 - ELEVATION B - S- TILE PLAN 2 - ELEVATION C - S- TILE FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5 FRONT OF HOUSE : 330° - 90°LAYOUT 1 FRONT OF HOUSE : 60° - 180°LAYOUT 2 FRONT OF HOUSE : 240° - 360°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5 NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2,333 SQ. FT. SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SUNPOWER 132 CELLS AC MODULES QUANTITY: 14 MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE 5.67 kWQ.PEAK DUO BLK ML-G10+ (405) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S U I T E 1 5 0 LA Q U I N T A , C A 9 2 2 5 3 IR V I N E C A 9 2 6 0 2 , U N I T E D S T A T E S SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125291 2/22/23 JOHN PAUL LINOGAO TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-2 PL A N 2 E L E V A T I O N A , B , A N D C 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 3 - ELEVATION A - S- TILE PLAN 3 - ELEVATION B - S- TILE PLAN 3 - ELEVATION C - S- TILE FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3 FRONT OF HOUSE : 60° - 90°LAYOUT 4 FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3 FRONT OF HOUSE : 60° - 90°LAYOUT 4 NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2,670 SQ. FT. SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.3 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SUNPOWER 132 CELLS AC MODULES QUANTITY: 14 MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE 5.67 kWQ.PEAK DUO BLK ML-G10+ (405) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX (TYP.) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S U I T E 1 5 0 LA Q U I N T A , C A 9 2 2 5 3 IR V I N E C A 9 2 6 0 2 , U N I T E D S T A T E S SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125291 2/22/23 JOHN PAUL LINOGAO TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-3.1 PL A N 3 E L E V A T I O N A , B , A N D C 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 OPT. EXT. COV. PATIO ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 3 - OPT. EXT. COV. PATIO - ELEVATION A - S- TILE PLAN 3 - OPT. EXT. COV. PATIO - ELEVATION B & C - S- TILE FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 0°LAYOUT 3 NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 2,670 SQ. FT. SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SLD REFERENCE PVE-1.1 SUNPOWER 132 CELLS AC MODULES QUANTITY: 14 MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE 5.67 kWQ.PEAK DUO BLK ML-G10+ (405) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) FRONT OF HOUSE : 60° - 90°LAYOUT 4 SLD REFERENCE PVE-1.1 FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX (TYP.) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S U I T E 1 5 0 LA Q U I N T A , C A 9 2 2 5 3 IR V I N E C A 9 2 6 0 2 , U N I T E D S T A T E S SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125291 2/22/23 JOHN PAUL LINOGAO TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-3.2 PL A N 3 - O P T . E X T . C O V . P A T I O E L E V A T I O N A , B , A N D C 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 LEGENDS: (3') WIDE ACCESS PATH (PITCHED ROOF) (4') WIDE ACCESS PATH (FLAT ROOF) PLAN TYPE OPTION DESCRIPTION 01 02 03 ----------------------------------- ----------------------------------- ----------------------------------- 04 05 ----------------------------------- ----------------------------------- FRONT OF HOUSE : 150° - 270°LAYOUT 1 FRONT OF HOUSE : 330° - 90°LAYOUT 2 PLAN 4 - ELEVATION A - S- TILE PLAN 4 - ELEVATION B - S- TILE PLAN 4 - ELEVATION C - S- TILE FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 90°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5 FRONT OF HOUSE : 60° - 180°LAYOUT 1 FRONT OF HOUSE : 240° - 360°LAYOUT 2 FRONT OF HOUSE : 330° - 90°LAYOUT 3 FRONT OF HOUSE : 150° - 180°LAYOUT 4 FRONT OF HOUSE : 240° - 270°LAYOUT 5 NOTE : - ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. - FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. BASE SQUARE FOOTAGE: 3,006 SQ. FT. SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.5 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SLD REFERENCE PVE-1.4 SUNPOWER 132 CELLS AC MODULES MODEL NO.NOMINAL POWER (Pnom) 405W SYSTEM SIZE Q.PEAK DUO BLK ML-G10+ (405) QUANTITY: 16 6.48 kW (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH)FRONT OF HOUSE (FOH) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) (E) SERVICE POINT AND UTILITY METERING TO ELECTRIC UTILITY GRID UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) (N) LOAD CENTER (INSIDE GARAGE) ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINTROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT ROOF ACCESS POINT TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX TRANSITION BOX (TYP.) TRANSITION BOX TRANSITION BOX (TYP.) E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S U I T E 1 5 0 LA Q U I N T A , C A 9 2 2 5 3 IR V I N E C A 9 2 6 0 2 , U N I T E D S T A T E S SO L A R M A S T E R P L A N P E R M I T P A C K A G E DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125291 2/22/23 JOHN PAUL LINOGAO TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVA-4 PL A N 4 E L E V A T I O N A , B , A N D C 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-1 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-2 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVS-3 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE A: SINGLE LINE DIAGRAM - 5.67 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 30A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 7 AC MODULESBRANCH CIRCUIT #2 7 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.1 TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE A: SINGLE LINE DIAGRAM - 5.67 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 30A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 4 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.2 TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE A: SINGLE LINE DIAGRAM - 5.67 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 30A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #10 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 6 AC MODULESBRANCH CIRCUIT #2 8 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.3 TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE A: SINGLE LINE DIAGRAM - 6.48 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 8 AC MODULESBRANCH CIRCUIT #2 8 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.4 TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE A: SINGLE LINE DIAGRAM - 6.48 KWDC UTILITY BIDIRECTIONAL METER (NOT CENTER-FED)INCOMING SOURCE FEED H MCB (E)MAIN SERVICE PANEL 200A, 120/240V, 1PH, 3W GND EXISTING GND TO HOUSE LOADS BREAKERS SHALL BE INSTALLED OPPOSITE END OF THE MAIN BREAKER 200A, 2P 40A,2P GND 3 NOTE: FOR SOLAR PHOTOVOLTAIC ONLY. NO ADDITIONAL LOADS TO BE APPLIED (N)LOAD CENTER 100A OR EQUIVALENT, 120/240V, 1PH 20A, 2P 20A, 2P TAG 1 2 3 4 5 SOURCE CIRCUIT TRANSITION BOX (N) LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT DESCRIPTION SOLAR AC MODULE / BRANCH 3 4 (N) LOAD CENTER PV PRODUCTION METER ELECTRICAL NOTES 1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. 2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM SUNPOWER. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY RIGID CONDUIT WITH MEYERS HUBS TO BE USED. 3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. 5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. 6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. 7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 8. TYPE NM CABLE OR EQUIVALENT CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. 9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 10. UN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. 12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. 13. THE DESIGN SPECIFIES THE MINIMUM REQUIRED WIRE SIZE. 14. WIRE GAUGE MAY BE UPSIZE TO ACCOMMODATE ADDITIONAL LENGTH OF THE WIRE DUE TO FIELD OBSERVED CHANGES IN THE LENGTH OF BRANCH WIRE TO LIMIT VOLTAGE DROP 15. PV BREAKER ACTS AS MEANS OF DISCONNECT WHEN AC DISCONNECT IS NOT REQUIRED. NOTE : x SUNPOWER 15A MONITORING BREAKER CAN BE RELOCATED TO OTHER LOAD CENTER OR SUB-PANEL WITHIN THE HOUSE FOR CONSTRUCTION FEASIBILITY. x BELOW ARE OPTIONAL OFFERINGS AND SHALL ONLY BE INSTALLED IF THE HOMEOWNER SIGNS A SPECIFIC CONTRACT WITH SUNPOWER. x SUNPOWER MONITORING SYSTEM x AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED. 1 2 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) 2 1 SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) #12 TYPE-ER, PER BRANCH CIRCUIT --WITH EGCA B TAG EATON DG221URB OR EQUIVALENT LOCATED OUTSIDE WITH VISIBLE KNIFE BLADES 5 NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B 3 1 GND C C UTILITY-LOCKABLE SAFETY SWITCH 30A, 240VAC #8 #10 OPTIONAL ETHERNET CONNECTION TO DSL/CABLE MODEM CAT5e CURRENT TRANSFORMERS (100A) INSTALLED ON THE CUSTOMER SIDE OF THE PANEL 1#14 NM CABLE OR EQ INSTALLED IN WALL CAVITY #22 NMFC CU-NM-B AWG TWISTED PAIR EGC BARE CU 3 INSTALLED IN WALL CAVITY 1/2" -- PRODUCTION CURRENT TRANSFORMERS (100A) SUNPOWER MONITORING PVS6 E #14 3 D E E D #6 15A, 2P 2 A DC AC DC AC 1 SUNPOWER MODULES AC MODULE EXTENSION CABLE NM CABLE OR EQ INSTALLED IN WALL CAVITY --EGC BARE CU CU-NM-B B 6 AC MODULESBRANCH CIRCUIT #2 10 AC MODULESBRANCH CIRCUIT #1 Q.PEAK DUO BLK ML-G10+ (405) #10 #10 IQ7HS-66-M-US (240) ATTIC ROOFTOP MICROINVERTER E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S TATE OF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® EL E C T R I C A L S I N G L E L I N E D I A G R A M & S P E C I F I C A T I O N SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S PVE-1.5 TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 FIGURE 2: WIRING ROOF PENETRATION CROSS SECTION FIGURE 1: ELECTRICAL SIGNAGES/STICKERS WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE x x x TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM x x x E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N EER S T ATEOF CA L I F O R NIA CHI F UNG L E UN G CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® x x x x x x PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VOLTS AMPS VOLTS PHOTOVOLTAIC POINT OF INTERCONNECTION WARNING: ELECTIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER PV POWER SOURCE MAXIMUM RATED AC OUTPUT CURRENT: MAXIMUM OPERATING AC VOLTAGE: 22.40 240 22.40 240 25.60 240 25.60 240 5.67 kW'&5.67 kW'& 6.48 kW'&6.48 kW'& PHOTOVOLTAIC SYSTEM COMBINER PANEL: DO NOT ADD LOADS x AC SOLAR DISCONNECT x SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D E T A I L S DRIVEWAY PVE-2 TYPICAL DIRECTORY PLACARD NOTE: CUSTOMIZED PLACARD WILL BE PROVIDED FOR EACH LOT(UNIT) N MAIN SERVICEPANEL LOAD CENTER PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAICARRAY ON ROOF POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: TR A N S I T I O N T O 4 0 5 W P A N E L 3 - 6 - 2 3 E C D 07/12/2023 REVISION 5: SYSTEM ATTRIBUTES CHANGED FOR 405W PANELS AND MICROINVETERS. BCPR2021-0030 CURRENT TRANSFORMER SPECIFICATION SHEET PVS6 DATASHEET 1 PVS6 DATASHEET 2 PVS6 INSTALLATION INSTRUCTIONS 2PVS6 INSTALLATION INSTRUCTIONS 1 Q-CABLE DATA SHEET 1/2 Q-CABLE DATA SHEET 2/2ENPHASE DATA SHEET 1/2 ENPHASE DATA SHEET 2/2 INVISIMOUNT DATA SHEET 1/2 INVISIMOUNT DATA SHEET 2/2 CONDUCTOR AND OCP SIZING TABLE PV MODULE SPECIFICATION SHEET 1/2 PV MODULE SPECIFICATION SHEET 2/2CERTIFICATE OF COMPLIANCE CLASS A FIRE RATING LISTING PG 1/3 CLASS A FIRE RATING LISTING PG 2/3 CLASS A FIRE RATING LISTING PG 3/3 CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATEOF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-3 UNIVERSAL INVISIMOUNT INSTALLATION GUIDE SOLADECK DATA SHEET CA N T E R A BE A Z E R H O M E S - S O U T H E R N C A L I F O R N I A 31 0 C O M M E R C E , S T E 1 5 0 LA Q U I N T A , C A L I F O R N I A 9 2 2 5 3 IR V I N E , C A 9 2 6 0 2 DRAWN BY PROJECT NO. DATE DRAWN COMMUNITY ID C002295 D-0125292 2023-03-05 ELEN DIMAALIHAN TH I S D O C U M E N T C O N T A I N S P R O P R I E T A R Y I N F O R M A T I O N . R E P R O D U C T I O N , DI S C L O S U R E , O R U S E W I T H O U T S P E C I F I C W R I T T E N A U T H O R I Z A T I O N O F T H E SU N P O W E R C O R P O R A T I O N I S S T R I C T L Y F O R B I D D E N . C O R P O R A T I O N , S Y S T E M S 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 (5 1 0 ) 5 4 0 - 0 5 5 0 C A L I C E N S E # 8 9 0 8 9 5 ® E LECT R I C A L E22659 Exp. 03-31-23R EGISTERE D P R O F ESSIONAL E N G I N E ER S TATEOF CA L I F O R NIA CHI F UNG L E UN G SHEET RE V D E S C R I P T I O N D A T E D B R E V I S I O N S EL E C T R I C A L D A T A & S P E C I F I C A T I O N S PVE-4