Loading...
Polo Villas TR 33085 BCPR2023-0002i3 SNAPSHOTPLAN •' 1 « --M9, CITY GF LA 141MITA wt cMrnn<<� Plan Type: Building Construction Plan Review Plan No.: BCPR2023-0002 Work Class: Building Construction Plan Review District: City of La Quinta Status: Approval Expired Square Feet: 0.00 Valuation: $0.00 Assigned To: Description: POLO VILLAS / TRACT CONSTRUCTION PLANS - SFDx7 OLO VILLAS / TRACT CONSTRUCTION MASTER PLANS FOR DWELLINGS FOR THE 2019 CODE CYCLE (SFDx7). 2022 CALIFORNIA BUILDING CODES. Parcel: 777500023 Main I Address: Polo Villas Main I Zone: App Date: 01 /27/2023 Exp Date: 01 /27/2024 Completed: 05/30/2023 Approval Expire Date: 05/29/2024 Architect Contractor ELEMENTAL ARCHITECTURE Leslie Stiles 5607 Council Grove ct 30875 DATE PALM DRIVE, #C. Houston, Tx 77088 #C2 Cathedral City, CA 92234 Plan Custom Fields Tract / Subdivision POLO VILLAS Tract Number 33085 Number of Plan Types SFDX7 Name Code Edition 2022 Is this a revision? No Zoning RVL General Plan LDR City Limits Within La Quinta City Acreage 0.13 Limits Subdivision Name TR 33085 Lot Number B Legal Description Lot B MB 460/25 TR 33085 Centerlines 16438 Lot Size 713.527 Attachment File Name Added On Added By Attachment Group Notes Construction Plan 09/19/2023 7:33 Ortega, AJ Available Online Construction Plan Set Set-2023-09-19-D 1 _v1. pdf Geotechnical 09/19/2023 7:33 Ortega, AJ Available Online Geotechnical Report Report-2023-09-19-Cl_v1. pdf Other Misc 09/19/2023 7:33 Ortega, AJ Available Online Other Misc Documents Documents-2023-09-19-A 1 _v 1. pdf Other Misc 09/19/2023 7:33 Ortega, AJ Available Online Other Misc Documents Documents-2023-09-19-B 1 _v 1. pdf Other Misc 09/19/2023 7:33 Ortega, AJ Available Online Other Misc Documents Documents-2023-09-19-1-1 _v1. pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 1 Calculations-2023-09-19-El_v1.pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 2 Calculations-2023-09-19-1`1_v1.pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 3 Calculations-2023-09-19-G 1 _v1. pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 4 Calculations-2023-09-19-1-11_v1.pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 5 Calculations-2023-09-19-I1_v1.pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 6 Calculations-2023-09-19-J 1 _v1. pdf Structural 09/19/2023 7:33 Ortega, AJ Available Online Structural Calculations Lot 7 Calculations-2023-09-19-K1_v1.pdf June 24, 2025 78-495 Calle Tampico Page 1 of 2 Workflow Step / Action Name Plan Check v.1 Linked Records v.1 Linked Permits v.1 Action Type Start Date End Date Create Sub Permit June 24, 2025 78-495 Calle Tampico Page 2 of 2 CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT uCv CASEY HARTMAN -- (ACTING) FIRE CHIE OFFICE OF THE FIRE MARSHAL — LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org June 13, 2023 GHA Companies 30875 Date Palm Drive #C-2 Cathedral City, CA 92234 Re: New Residential Building - Fire Plan Review — POLO VILLAS — TR 33085 BCPR2023-0002 / 51317 MADISON STREET, LA QUINTA, CA 92253 The building plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Fire Department approval is based upon the 2022 CBC/CRC requirements for R-3/U occupancies in a planned/tract community. TRACT ACCESS & WATER REQUIREMENTS: ACCESS Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, La Quinta Municipal Code and Riverside County Fire Department Standards. 1) Certain designed areas will be required to be maintained as fire lanes and will require approved signs and/or red painted curbs. 2) Vehicle access gates shall be provided with KNOX Box, Padlock or Key -switch access. Automatic gates shall also have Opticom IR receivers. 3) Approved street signs shall be installed and visible. 4) No Traffic Calming Devices shall be installed. *Future/proposed traffic calming devices require approval by the Office of the Fire Marshal. WATER 1) Fire hydrants shall be installed within 600 feet hose -lay length of the proposed residential units. 2) An observable minimum fire flow shall be present upon testing. 3) Fire hydrant caps shall be in place and marked in accordance with local requirements. 4) Blue roadway reflector shall be installed in the completed roadway to identify the location of all fire hydrants. 5) Hydrant roadway valve boxes shall have their coverplate or lid exposed and easily accessible. PRIOR TO PERMIT RELEASE INSPECTION 1) Individual Tract Home (Production) permits will not be released until a Tract Access/Water inspection has been completed for the affected phase or row of f lots. Applicant/Contractor shall be responsible for contacting the Office of the Fire Marshal to schedule inspections. Request for inspections are to be made at least 48 hours in advance and may be arranged by calling 760-777-7131. DEFERRED SUBMITTALS REQUIRED 1) A Residential Fire Sprinkler system shall be installed in compliance with CRC R313. CA Licensed Contractor (C-16) shall submit plans and details for review and approval prior to Rough Inspections. a. Residential Fire Sprinkler permits may be applied for as Master Plan Types. A single Fire Sprinkler Master Plan permit for each different plan lype may be individually applied for. Coordinate with the La Quinta Permit Technicians for appropriate application and fee process. GENERAL CONDITIONS 1) Property/Unit Addressing shall be provided. Minimum 4-inch tall numbers of contrasting color to their background shall be posted on the structure when viewable from the roadway, or at the driveway entrance and maintained visible from both directions of travel. 2) All HOA and Private landscaping shall maintain a minimum 3-feet radius clearance around the circumference of fire protection equipment, that includes fire hydrants. 3) Dwelling Units shall maintain a minimum 3-feet clear width Egress Court from emergency escape windows and doors of sleeping rooms, and shall deposit to the front of the property or public way. (Ref. CBC 1028.4 / CRC R311.1) 4) Energy Storage Systems shall comply with CFC 1207.11. a. Fire Detection - Areas shall be protected by smoke alarms. A listed heat detector shall be installed in locations within dwelling units and attached garages where smoke alarms cannot be installed based on their listing. b. Protection from Impact — ESS installed in a location subject to vehicle damage shall be protected by approved barriers. c. Operating Temperatures — ESS system manuals shall be consulted. Compliance with the maximum operating ambient temperatures shall be complied with. Provision of HVAC climate control may be necessary. The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Kohl Hetrick - Fire Safety Specialist Development / Construction I RE Investment Duality , Service I Reliability I Est 1981 July 10. 2023 Mr Jon McMillen City of La Ouinta / City Manager 78-495 Calle Tampico La Ouinta CA 92253 RE: Request for modified work hours. Polo Estates Development Dear Mr. McMillen: I hope you are well. please aecu: ), this letter as my formal request to allow our field staff and crews to commence work at the Pogo Villas Project Tract No. 33085 at 5 00 a m instead of your posted 6 00 a.m., from Mondays through Fridays only We would maintain the cities posted work schedule for the weekends As you know our world is experiencing record heat. the inclement desert weather makes for very harsh working conditions. and being able to start work one -hour earlier would be beneficial to the health. safety. and production of our crews I hubbly ask that you support this request. our protect is isolated. and we own the properties to the north (existing 11 homes) Should you grant my request and down the road experience issues or complaints with starting one -hour earlier I would stop. and start at 6 00 a.m . per the city ordinance I appreciate your time and consideration, should you have questions or want to discuss please contact me anytime. Thank you so much City Manager. Respectfully submitted Request Approved Mano J Gonzales GHA Companies President f CEO Project General Contractor Polo Villas Development (760) 250-8611 cell manoLd�qhacompanies com cc Carlos Bonilla (GHA Sr. Project Manager) Pat Schlicht (GHA Vice President of Construction) 30-875 Date Palm Drive, S Ae C. Cathedral City. Cairtornia 92234 Tel (760) 969-1400 • Fax (760) 322-6333 • www gnacompanies.com General Bulk" Con&wW CA License No. 7S0957 LANDMARK a MBE Company March 24, 2023 Mr. Ryan Nelson Built to Stay — Polo Villas, LLC ABTS Polo Villas, LLC 2425 S. Stearman Drive, Suite 220 Chandler, AZ 85386 780 N. 4th Street El Centro, CA 92243 (760) 370-3000 landmark@landmark-ca.com 77-948 Wildcat Drive Palm Desert, CA 92211 (760) 360-0665 gchandra@landmark-ca.com BCPR2023-0002 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ME05/30/2023 wr Subject: Tract No. 33085 — Polo Villas POLO VILLAS - SFDx7 La Quinta, California LCI Report No.: LP19044 References: Rough Grading Plan & Storm Drain Improvements for Tract Map No. 33085, prepared by Coachella Valley Engineers, signed date December 29, 2022. Structural Plans for Polo Villas, prepared by GMEP Engineers, dated February 22, 2023. Dear Mr. Nelson: In response to your request, LandMark Consultants, Inc. has reviewed from a geotechnical standpoint the grading and foundation plans, for the subject project: • Grading Plans sheets 1 thru 3 • Foundation Plans sheets SN-1; SN-2; 5-1.0; S-2.OA; S-2.OB; S-3.OA; S3-013; 5-4.0; S-5.0; S-6.OA; S-6.013; S-7.OA; S-7.013 and SD-1 The purpose of our review was to evaluate compliance with the intent of the recommendations contained in our geotechnical investigation report for the subject site. The submitted plans are in conformance with the recommendations presented in our geotechnical report update for Tract No. 33085 prepared by Landmark Consultants, Inc., dated August 26, 2022. We have prepared this letter for your exclusive use in substantial accordance with the generally accepted geotechnical engineering practice as it existed in the site area at the time of our study. No warranty is expressed or implied. It should be noted that the submitted plans were not reviewed for conformance with other clients', governmental or consultant requirements. Tract No. 33085 — Polo Villas LCI Report No.: LP22251 We appreciate the opportunity to be of service. Should you have any questions, please call our office. Sincerely Yours, LandMark Consultants, Inc. Greg M. Chandra, P.E., M.ASCE Principal Engineer Q,�kpFESSIpN C Hgti �/F'L � m C No. C 34432 a Landmark Consultants, Inc.