Loading...
Point Happy TR 31348 BCPR2022-0016PLAN SNAPSHOT REPORT BCPR2022-0016 FOR CITY OF LA QUINTA Building Construction Plan Review 08/08/2022App Date:Plan No.:Plan Type:BCPR2022-0016 City of La QuintaBuilding Construction Plan Review 06/29/2024Exp Date:District:Work Class: 0.00Expired NOT COMPLETEDCompleted:Square Feet:Status: Description: Valuation: POINT HAPPY / MASTER SOLAR PLANS FOR THE 2019 CODE CYCLE POINT HAPPY / SOLAR PHOTOVOLTAIC MASTER PLANS FOR PLAN TYPES 1, 2 & 2X FOR THE 2019 CODE CYCLE. INDIVIDUAL PERMITS TO BE ISSUED FOR EACH ADDRESS. 2019 CALIFORNIA BUILDING CODES. ALL PLAN TYPES: 6.3kW SOLAR ARRAY - (18) 350W LSUNPOWER SPR-X21-350-BLK-E-AC MODULES W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF]. SOLAR ARRAY TO BE ORIENTED BETWEEN 105°-300° AZIMUTH.Edit REVISION #1 - NEW ROOF LAYOUTS + NEW SYSTEM ATTRIBUTES OF ALL PLAN TYPES: 6.48kW SOLAR ARRAY - (16) 405W HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ PANELS + W/ (16) ENPHASE IQ7HS-66-M-US MICROINVERTERS [346SF] REVISION #2 - ADDITION OF OPTIONAL ESS $0.00 Assigned To:Approval Expire Date:06/29/2024 Parcel:Main643240044 Address:Point Happy Main Zone: Applicant Jared Nast 195 Park Dr Apt C Boston, MA 02215 Contractor Amy Clemans 1414 HARBOUR WAY S SUITE 1901 RICHMOND, CA 94804 Applicant Amy Clemans 1414 HARBOUR WAY S SUITE 1901 RICHMOND, CA 94804 Plan Custom Fields Tract / Subdivision Name POINT HAPPY Tract Number 31348 Model/Series Name MASTER SOLAR PLANS Number of Plan Types SFDX3 Code Edition 2019 Is this a revision?No General Plan ROW City Limits Within La Quinta City Limits Acreage 2.3 Subdivision Name TR 31348 AMEND Lot Number I Legal Description Lot I MB 390/1 TR 31348 AMEND Centerlines 88528, 87924, 88204, 88526, 87927, 88529, 87925, 87928, 87929, 87926 Lot Size 13511 Attachment File Name Added On Added By Attachment Group Notes BCPR2022-0016 - REVISION 1 - SOLAR PLAN (APPROVED).pdf 09/21/2023 22:54 Ortega, AJ Available Online BCPR2022-0016 - SOLAR MASTER PLANS (APPROVED).pdf 09/21/2023 22:54 Ortega, AJ Available Online BCPR2022-0016 - TAKEOFF SHEETS.pdf 09/21/2023 22:54 Ortega, AJ Internal Only TAKE OFF SHEETS Point Happy master Resubmittal Letter.pdf 09/21/2023 22:54 Ortega, AJ Available Online DO NOT USE -- INCORRECT.pdf 12/19/2023 10:20 Fuson, Jake Internal Only Construction Plan Set REVISION #2 - NARRATIVE OF CHANGES.pdf 12/19/2023 10:20 Fuson, Jake Available Online Revision Narrative DO NOT USE -- INCORRECT.pdf 12/19/2023 10:35 Fuson, Jake Internal Only REVISION #2 - MASTER PLAN (APPROVED).pdf 12/20/2023 13:43 Fuson, Jake Available Online Page 1 of 578-495 Calle TampicoJune 24, 2025 PLAN SNAPSHOT REPORT (BCPR2022-0016) Created ByNote Date and Time Created 1.Deisy MendezMUST SUBMIT A REVISED NARRATIVE LETTER TO INDICATE THE SYSTEM SIZE CHANGES 01/18/2024 14:53 Invoice No.Amount PaidFeeFee Amount INV-00003192 $218.75 Hourly Charge - City Building Staff $218.75 $5.47 Credit Card Convenience Fee $5.47 $224.22 $224.22 Total for Invoice INV-00003192 Grand Total for Plan $224.22 $224.22 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Revision Review v.1 09/22/2023 09/29/2023 11/20/2023 Yes Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1 Day)Building Fuson, Jake Revisions Required 09/22/2023 09/29/2023 11/17/2023 Comments: REVISION #1 - ADD OPTIONAL ESS Correction Type Category Corrective ActionComments Resolved Create Date Resolved Date Building Review - Correction Building Review - Correction -CONDUCTORS AND SUBPANEL ARE SHOWN AS 'EXISTING BY OTHERS' HOWEVER NO SUBPANEL IS SHOWN IN THE SINGLE LINE DIAGRAM OF THE DWELLING PLANS, PLEASE REVISE. -ALUMINUM CONDUCTORS SHALL NOT BE SMALLER THAN 1/0 AWG PER LQMC 8.03.030, PLEASE REVISE -ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE PROTECTED BY A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS. (CRC R328.7) -IT APPEARS THAT THE OUTPUT CURRENT FROM THE HUB+ AND THE GRID WILL EXCEED THE MAXIMUM AMPACITY OF THE BUSBAR AT THE MAIN SERVICE PANEL. PLEASE DEMONSTRATE COMPLIANCE WITH CEC 705.12(B)(2)(3) Building Department review correction No 11/17/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed ApprovedBuilding Revision Review v.2 11/29/2023 12/06/2023 12/19/2023 No Yes Page 2 of 578-495 Calle TampicoJune 24, 2025 PLAN SNAPSHOT REPORT (BCPR2022-0016) Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1 Day)Building Fuson, Jake Approved 11/29/2023 12/06/2023 12/19/2023 Comments: REVISION #2 - ADDITION OF OPTIONAL ESS Correction Type Category Corrective ActionComments Resolved Create Date Resolved Date Building Review - Correction Building Review - Correction -CONDUCTORS AND SUBPANEL ARE SHOWN AS 'EXISTING BY OTHERS' HOWEVER NO SUBPANEL IS SHOWN IN THE SINGLE LINE DIAGRAM OF THE DWELLING PLANS, PLEASE REVISE. -ALUMINUM CONDUCTORS SHALL NOT BE SMALLER THAN 1/0 AWG PER LQMC 8.03.030, PLEASE REVISE -ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE PROTECTED BY A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS. (CRC R328.7) -IT APPEARS THAT THE OUTPUT CURRENT FROM THE HUB+ AND THE GRID WILL EXCEED THE MAXIMUM AMPACITY OF THE BUSBAR AT THE MAIN SERVICE PANEL. PLEASE DEMONSTRATE COMPLIANCE WITH CEC 705.12(B)(2)(3) Building Department review correction Yes 11/29/2023 12/19/2023 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Revision Review v.1 12/20/2023 12/29/2023 01/10/2024 Yes Yes Page 3 of 578-495 Calle TampicoJune 24, 2025 PLAN SNAPSHOT REPORT (BCPR2022-0016) Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Fuson, Jake Revisions Required 12/20/2023 12/29/2023 01/09/2024 Comments: REVISION #2 Correction Type Category Corrective ActionComments Resolved Create Date Resolved Date Building Review - Correction Building Review - Correction 1) Revise note on cover sheet to read: “All construction shall comply with the 2019 California Residential, Mechanical, Electrical, Plumbing, Green Building and Energy Codes and the La Quinta Municipal Code.” Remove notes referencing other codes. 2) The equipment was changed from the original submittal, please provide the installation manuals for the IQ System Controller and the IQ Battery 5P. 3) Aluminum conductors are permitted only if size 1/0 or larger, and only to feed main or sub-panels. All other current carrying conductors shall be copper. Please revise conduit/conductor tag “C”. (LQMC §8.03.040) 4) Conductors and subpanel are shown as 'existing by others' however no subpanels are shown in the single line diagram of the dwelling plans, revised plans must be approved through the dwelling plans prior to approval of these revised solar plans. Building Department review correction No 01/09/2024 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Revision Review v.2 01/22/2024 01/29/2024 01/26/2024 Yes Yes Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Fuson, Jake Revisions Required 01/22/2024 01/29/2024 01/26/2024 Comments: REV3 - PC2. See 'Corrections' tab. Correction Type Category Corrective ActionComments Resolved Create Date Resolved Date Building Review - Correction Building Review - Correction The original Revision #3 narrative did not denote the reduction in DC system size. After review, the proposed DC system sizes of plans 2 & 2X do not meet the minimum required by the energy report (6.2kW & 6.14kW). Other previous corrections have been resolved. Building Department review correction No 01/22/2024 Submittal Name Status Received Date Due Date Complete Date Resubmit Completed Requires Re-submitBuilding Revision Review v.3 02/12/2024 02/20/2024 02/15/2024 Yes Yes Page 4 of 578-495 Calle TampicoJune 24, 2025 PLAN SNAPSHOT REPORT (BCPR2022-0016) Completed Date Due Date Assigned DateStatusAssigned UserDepartmentItem Review Name Building (1WK)Building Fuson, Jake Revisions Required 02/12/2024 02/20/2024 02/15/2024 Comments: See "Corrections" tab. Correction Type Category Corrective ActionComments Resolved Create Date Resolved Date Building Review - Correction Building Review - Correction Same correction applies, if Title 24 Energy Report has been revised it must be submitted for review and approval under the tract dwelling construction plans in order to be utilized to grant solar PV approvals. Building Department review correction No 02/12/2024 Workflow Step / Action Name Action Type Start Date End Date Plan Check v.1 12/19/2023 10:20 Building Revision Review v.1 Receive Submittal 09/22/2023 0:00 11/20/2023 7:33 Building Revision Review v.2 Receive Submittal 11/29/2023 0:00 12/19/2023 10:20 Building Revision Review v.1 Receive Submittal 12/20/2023 0:00 01/10/2024 8:17 Building Revision Review v.2 Receive Submittal 01/22/2024 0:00 01/26/2024 11:47 Building Revision Review v.3 Receive Submittal 02/12/2024 0:00 02/15/2024 10:50 Building Revision Review v.4 Receive Submittal 02/15/2024 0:00 Linked Records v.1 Linked Permits v.1 Create Sub Permit Page 5 of 578-495 Calle TampicoJune 24, 2025 BCPR2022-0016 – POINT HAPPY MASTER SOLAR PLAN TAKE-OFFS PLAN 1, 2 & 2X Permit Notes: PLAN 1, 2 OR 2X: 6.3kW SOLAR ARRAY - (18) 350W LSUNPOWER SPR-X21-350-BLK-E-AC MODULES W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF]. SOLAR ARRAY TO BE ORIENTED BETWEEN 105°-300° AZIMUTH. 2019 CALIFORNIA BUILDING CODES. Description: POINT HAPPY / 6.3kW PV SYSTEM - (18) AC MODULES +100A SUB Fee Breakdown: - Building Standards Administration (BSAS) - Electrical 2019 o PV System less than 10kW PC o PV System less than 10kW - Permit issuance - Records Management Fee - Technology Enhancement Fee 3/3/2023 BUILDING AND SAFETY DEPARTMENT City of La Quinta RE: RESUBMITAL LETTER Plan Check Number/Permit Number: Project Name: Project Address: Project Description:Rooftop Photovoltaic System Master Plan Permit Package for Point Happy Sheet No. PVA-0 to PVA-1 PVE- 1 to PVE-3 Should you have any additional questions, feel free to contact me. Sincerely, _____________________________ Gellie Greagnda / Design Engineer Gellie.Greganda@sunpowercorp.com 1 TRANSITIONED TO 405W HANWHA Q-CELL AND UPDATED ELECTRICAL SHEETS Change No. Description of Change Point Happy La Quinta, California 92253 9/12/2023 BUILDING AND SAFETY DEPARTMENT City of La Quinta RE: RESUBMITTAL LETTER Plan Check Number/Permit Number: Project Name:Point Happy Project Address: Sheet No. PVA-0, PVA-4 to PVA-6, PVE-1.2, PVE-1.4, PVE-2, PVE-3, PVE-5 Should you have any additional questions, feel free to contact me. Sincerely, _____________________________ John Albert Reyes / Design Engineer JohnAlbert.Reyes@sunpowercorp.com 2 ADDED ESS OPTION Change No. Description of Change La Quinta, California 92253 Rooftop Photovoltaic System Master Plan Permit Package for Point HappyProject Description: