Loading...
Point Happy TR 31348 BCPR2023-0012 (Plan 2) Title 24 - Revision 1CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 1 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 GENERAL INFORMATION 01 Project Name Point Happy - Plan #2 02 Run Title Title 24 Analysis 03 Project Location Point Happy 04 City La Quinta 05 Standards Version 2022 06 Zip code 92253 07 Software Version EnergyPro 9.2 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.33 18 Total Cond. Floor Area (ft2)3215 19 Glazing Percentage (%)14.73% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. REVISION #1 BCPR2023-0012 REVISED PV SYSTEM SIZE FOR PLAN #2 05/30/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 2 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 30.7 38.9 20 Proposed Design North Facing 29.1 37.6 18.8 1.6 1.3 1.2 East Facing 29.2 37.3 18.7 1.5 1.6 1.3 South Facing 29.4 38 19.2 1.3 0.9 0.8 West Facing 29.1 37.5 18.7 1.6 1.4 1.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 5.65 kWdc 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 3 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.27 1.27 0.3 2.19 -0.03 -0.92 Space Cooling 3.07 57.95 3.2 58.58 -0.13 -0.63 IAQ Ventilation 0.29 3.05 0.29 3.05 0 0 Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71 Self Utilization/Flexibility Credit -7.41 7.41 North Facing Efficiency Compliance Total 4.13 67.37 5.83 65.22 -1.7 2.15 Space Heating 0.27 1.27 0.31 2.23 -0.04 -0.96 Space Cooling 3.07 57.95 3.2 58.05 -0.13 -0.1 IAQ Ventilation 0.29 3.05 0.29 3.05 0 0 Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71 Self Utilization/Flexibility Credit -7.41 7.41 East Facing Efficiency Compliance Total 4.13 67.37 5.84 64.73 -1.71 2.64 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 4 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.27 1.27 0.29 2.1 -0.02 -0.83 Space Cooling 3.07 57.95 3.21 58.77 -0.14 -0.82 IAQ Ventilation 0.29 3.05 0.29 3.05 0 0 Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71 Self Utilization/Flexibility Credit -6.8 6.8 South Facing Efficiency Compliance Total 4.13 67.37 5.83 65.93 -1.7 1.44 Space Heating 0.27 1.27 0.25 1.77 0.02 -0.5 Space Cooling 3.07 57.95 3.23 58.75 -0.16 -0.8 IAQ Ventilation 0.29 3.05 0.29 3.05 0 0 Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71 Self Utilization/Flexibility Credit -7.41 7.41 West Facing Efficiency Compliance Total 4.13 67.37 5.81 64.97 -1.68 2.4 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 5 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage North Facing Gross EUI1 12.44 14.15 -1.71 -13.75 Net EUI2 2.2 4.21 -2.01 -91.36 East Facing Gross EUI1 12.44 14.13 -1.69 -13.59 Net EUI2 2.2 4.18 -1.98 -90 South Facing Gross EUI1 12.44 14.26 -1.82 -14.63 Net EUI2 2.2 4.32 -2.12 -96.36 West Facing Gross EUI1 12.44 14.21 -1.77 -14.23 Net EUI2 2.2 4.26 -2.06 -93.64 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 6 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 6.07 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 97 95 BATTERY SYSTEMS 01 02 03 04 05 06 07 Control Capacity (kWh) Charging Discharging Round Trip Efficiency Charging Efficiency Charging Rate (kW)Discharging Efficiency Discharging Rate (kW) TOU 10 0.95 n/a 0.95 n/a 0.9 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV module type: Premium •PV power electronics: Microinverters •Battery System: 10 kWh (Self Utilization Credit taken) •Non-standard roof reflectance •Insulation below roof deck •Window overhangs and/or fins 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 7 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Verified heat pump rated heating capacity •Duct leakage testing •Low-leakage Air Handling Unit •Pipe Insulation, All Lines BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Point Happy - Plan #2 3215 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status House Conditioned HVAC1 3215 10 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front 2x6 Wall House R-21 Wall 0 Front 340 112.5 90 Left 2x6 Wall House R-21 Wall 90 Left 520 50 90 Back 2x6 Wall House R-21 Wall 180 Back 550 232 90 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 8 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Right 2x6 Wall House R-21 Wall 270 Right 760 103 90 Front 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 210 0 n/a Left 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 370 21 n/a Rigjht 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 130 0 n/a Vented Attic House R-38 Ceiling w/R-13@Roof.n/a n/a 3075 n/a n/a Vented Attic @ FAU House R-21@FAU w/R-13@Roof.n/a n/a 140 n/a n/a Garage Ceiling __Garage__R-0 Garage Ceiling n/a n/a 653 n/a n/a FG Wall __Garage__R-0 Wall 0 Front 210 128 90 LG Wall __Garage__R-0 Wall 90 Left 240 0 90 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.16 0.89 No No Attic House Attic RoofHouse Ventilated 4 0.16 0.89 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Front Openable Window Front 2x6 Wall Front 0 1 30 0.29 NFRC 0.21 NFRC Bug Screen Front Fixed Window Front 2x6 Wall Front 0 1.5 7 1 10.5 0.27 NFRC 0.22 NFRC Bug Screen Front Hinged Glass Door Window Front 2x6 Wall Front 0 1 48 0.25 NFRC 0.16 NFRC Bug Screen Left Openable Window Left 2x6 Wall Left 90 1 50 0.29 NFRC 0.21 NFRC Bug Screen 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 9 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Back Sliding/Folding Glas Window Back 2x6 Wall Back 180 12 8 1 96 0.4 NFRC 0.23 NFRC Bug Screen Back Sliding/Folding Glas 2 Window Back 2x6 Wall Back 180 12 8 1 96 0.4 NFRC 0.23 NFRC Bug Screen Back Openable Window Back 2x6 Wall Back 180 1 40 0.29 NFRC 0.21 NFRC Bug Screen Right Openable Window Right 2x6 Wall Right 270 1 103 0.29 NFRC 0.21 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor Front Door Front 2x6 Wall 24 0.2 Left Garage Door Left 2x6 Garage Wall 21 0.5 Car Door FG Wall 128 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Front Fixed 4 0 2 2 0 0 0 0 0 0 0 0 0 Back Sliding/Folding Glas 12 0 2 2 0 0 0 0 0 0 0 0 0 Back Sliding/Folding Glas 2 12 0 2 2 0 0 0 0 0 0 0 0 0 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 10 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade House 3215 217 none 0 80%No Garage Slab __Garage__653 45 none 0 0%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361 Inside Finish: Gypsum Board Cavity / Frame: no insul. / 2x4 Exterior Finish: 3 Coat Stucco R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco R-21 Wall House/Garage Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064 Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: no insul. / 2x4 Attic RoofHouse Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-13 None / 0 0.072 Roofing: 10 PSF (RoofTileAirGap) Tile Gap: present Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-0.0 insul. 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 11 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-0 Garage Ceiling Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 Inside Finish: Gypsum Board R-38 Ceiling w/R-13@Roof. Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board R-21@FAU w/R-13@Roof. Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-21 None / None 0.044 Over Ceiling Joists: R-11.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 1 n/a None DHW Sys 1-hers-dhw DHW Heater 1 (1) 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 12 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location DHW Heater 1 Gas Consumer Instantaneo us 1 0 UEF 0.93 Btu/Hr 200000 0 n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC1 Heat pump heating cooling Heat Pump System 1 2 Heat Pump System 1 2 HVAC Fan 1 Air Distribution System 1 Setback 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 13 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 2 HSPF2 7.5 33000 19000 EER2SEER2 14.3 12 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Required Not Required Yes No Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution System 1-hers-dist 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 14 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 121 0.35 Exhaust No n/a / n/a No Yes 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 15 of 15) Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-11-30   13:59:38 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Rick Maurer Rick Maurer Title 24, Inc.11/30/2023 7544 E. Saddlehill Trail R19-90-30037 Orange, CA 92869 714-771-1507 Zachary Nordby Williams Homes, Inc.11/30/2023 24911 Avenue Stanford 734097 Santa Clarita, CA 91355 661-222-9207 423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.