Point Happy TR 31348 BCPR2023-0012 (Plan 2) Title 24 - Revision 1CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 1 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
GENERAL INFORMATION
01 Project Name Point Happy - Plan #2
02 Run Title Title 24 Analysis
03 Project Location Point Happy
04 City La Quinta 05 Standards Version 2022
06 Zip code 92253 07 Software Version EnergyPro 9.2
08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)All orientations
10 Building Type Single family 11 Number of Dwelling Units 1
12 Project Scope Newly Constructed 13 Number of Bedrooms 3
14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1
16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.33
18 Total Cond. Floor Area (ft2)3215 19 Glazing Percentage (%)14.73%
20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
22 Fuel Type Natural gas 23 No Dwelling Unit:No
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
REVISION #1
BCPR2023-0012
REVISED PV SYSTEM
SIZE FOR PLAN #2
05/30/2024
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 2 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
ENERGY DESIGN RATINGS
Energy Design Ratings Compliance Margins
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Source Energy
(EDR1)
Efficiency1 EDR
(EDR2efficiency)
Total2 EDR
(EDR2total)
Standard Design 30.7 38.9 20
Proposed Design
North Facing 29.1 37.6 18.8 1.6 1.3 1.2
East Facing 29.2 37.3 18.7 1.5 1.6 1.3
South Facing 29.4 38 19.2 1.3 0.9 0.8
West Facing 29.1 37.5 18.7 1.6 1.4 1.3
RESULT3: PASS
1Efficiency EDR includes improvements like a better building envelope and more efficient equipment
2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries
3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded
•Standard Design PV Capacity: 5.65 kWdc
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 3 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.27 1.27 0.3 2.19 -0.03 -0.92
Space Cooling 3.07 57.95 3.2 58.58 -0.13 -0.63
IAQ Ventilation 0.29 3.05 0.29 3.05 0 0
Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71
Self
Utilization/Flexibility
Credit
-7.41 7.41
North Facing
Efficiency Compliance
Total
4.13 67.37 5.83 65.22 -1.7 2.15
Space Heating 0.27 1.27 0.31 2.23 -0.04 -0.96
Space Cooling 3.07 57.95 3.2 58.05 -0.13 -0.1
IAQ Ventilation 0.29 3.05 0.29 3.05 0 0
Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71
Self
Utilization/Flexibility
Credit
-7.41 7.41
East Facing Efficiency
Compliance Total 4.13 67.37 5.84 64.73 -1.71 2.64
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 4 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
ENERGY USE SUMMARY
Energy Use Standard Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Standard Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Proposed Design Source
Energy (EDR1) (kBtu/ft2 -yr)
Proposed Design TDV Energy
(EDR2) (kTDV/ft2 -yr)
Compliance
Margin (EDR1)
Compliance
Margin (EDR2)
Space Heating 0.27 1.27 0.29 2.1 -0.02 -0.83
Space Cooling 3.07 57.95 3.21 58.77 -0.14 -0.82
IAQ Ventilation 0.29 3.05 0.29 3.05 0 0
Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71
Self
Utilization/Flexibility
Credit
-6.8 6.8
South Facing
Efficiency Compliance
Total
4.13 67.37 5.83 65.93 -1.7 1.44
Space Heating 0.27 1.27 0.25 1.77 0.02 -0.5
Space Cooling 3.07 57.95 3.23 58.75 -0.16 -0.8
IAQ Ventilation 0.29 3.05 0.29 3.05 0 0
Water Heating 0.5 5.1 2.04 8.81 -1.54 -3.71
Self
Utilization/Flexibility
Credit
-7.41 7.41
West Facing Efficiency
Compliance Total 4.13 67.37 5.81 64.97 -1.68 2.4
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 5 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
ENERGY USE INTENSITY
Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage
North Facing
Gross EUI1 12.44 14.15 -1.71 -13.75
Net EUI2 2.2 4.21 -2.01 -91.36
East Facing
Gross EUI1 12.44 14.13 -1.69 -13.59
Net EUI2 2.2 4.18 -1.98 -90
South Facing
Gross EUI1 12.44 14.26 -1.82 -14.63
Net EUI2 2.2 4.32 -2.12 -96.36
West Facing
Gross EUI1 12.44 14.21 -1.77 -14.23
Net EUI2 2.2 4.26 -2.06 -93.64
Notes
1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.
2. Net EUI is Energy Use Total (including PV) / Total Building Area.
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 6 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
Array Angle
(deg)
Tilt: (x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
6.07 NA Premium (~18-20%)Fixed Microinverters true 105-300 n/a n/a <=7:12 97 95
BATTERY SYSTEMS
01 02 03 04 05 06 07
Control Capacity (kWh)
Charging Discharging
Round Trip Efficiency
Charging Efficiency Charging Rate (kW)Discharging Efficiency Discharging Rate (kW)
TOU 10 0.95 n/a 0.95 n/a 0.9
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
•PV module type: Premium
•PV power electronics: Microinverters
•Battery System: 10 kWh (Self Utilization Credit taken)
•Non-standard roof reflectance
•Insulation below roof deck
•Window overhangs and/or fins
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 7 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
•Quality insulation installation (QII)
•Indoor air quality ventilation
•Kitchen range hood
•Minimum Airflow
•Verified EER/EER2
•Verified Refrigerant Charge
•Fan Efficacy Watts/CFM
•Verified heat pump rated heating capacity
•Duct leakage testing
•Low-leakage Air Handling Unit
•Pipe Insulation, All Lines
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Point Happy - Plan #2 3215 1 3 1 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status
House Conditioned HVAC1 3215 10 DHW Sys 1 New
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Front 2x6 Wall House R-21 Wall 0 Front 340 112.5 90
Left 2x6 Wall House R-21 Wall 90 Left 520 50 90
Back 2x6 Wall House R-21 Wall 180 Back 550 232 90
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 8 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt (deg)
Right 2x6 Wall House R-21 Wall 270 Right 760 103 90
Front 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 210 0 n/a
Left 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 370 21 n/a
Rigjht 2x6 Garage Wall House>>__Garage__R-21 Wall House/Garage n/a n/a 130 0 n/a
Vented Attic House R-38 Ceiling w/R-13@Roof.n/a n/a 3075 n/a n/a
Vented Attic @ FAU House R-21@FAU w/R-13@Roof.n/a n/a 140 n/a n/a
Garage Ceiling __Garage__R-0 Garage Ceiling n/a n/a 653 n/a n/a
FG Wall __Garage__R-0 Wall 0 Front 210 128 90
LG Wall __Garage__R-0 Wall 90 Left 240 0 90
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__Attic Garage Roof Cons Ventilated 4 0.16 0.89 No No
Attic House Attic RoofHouse Ventilated 4 0.16 0.89 No No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Front Openable Window Front 2x6 Wall Front 0 1 30 0.29 NFRC 0.21 NFRC Bug Screen
Front Fixed Window Front 2x6 Wall Front 0 1.5 7 1 10.5 0.27 NFRC 0.22 NFRC Bug Screen
Front Hinged
Glass Door Window Front 2x6 Wall Front 0 1 48 0.25 NFRC 0.16 NFRC Bug Screen
Left Openable Window Left 2x6 Wall Left 90 1 50 0.29 NFRC 0.21 NFRC Bug Screen
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 9 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC SHGC Source Exterior Shading
Back
Sliding/Folding
Glas
Window Back 2x6 Wall Back 180 12 8 1 96 0.4 NFRC 0.23 NFRC Bug Screen
Back
Sliding/Folding
Glas 2
Window Back 2x6 Wall Back 180 12 8 1 96 0.4 NFRC 0.23 NFRC Bug Screen
Back Openable Window Back 2x6 Wall Back 180 1 40 0.29 NFRC 0.21 NFRC Bug Screen
Right Openable Window Right 2x6 Wall Right 270 1 103 0.29 NFRC 0.21 NFRC Bug Screen
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Front Door Front 2x6 Wall 24 0.2
Left Garage Door Left 2x6 Garage Wall 21 0.5
Car Door FG Wall 128 0.5
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Window
Overhang Left Fin Right Fin
Depth Dist Up Left Extent Right
Extent Flap Ht.Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
Front Fixed 4 0 2 2 0 0 0 0 0 0 0 0 0
Back Sliding/Folding Glas 12 0 2 2 0 0 0 0 0 0 0 0 0
Back Sliding/Folding Glas 2 12 0 2 2 0 0 0 0 0 0 0 0 0
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 10 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth Carpeted Fraction Heated
Slab-on-Grade House 3215 217 none 0 80%No
Garage Slab __Garage__653 45 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-0 None / None 0.361
Inside Finish: Gypsum Board
Cavity / Frame: no insul. / 2x4
Exterior Finish: 3 Coat Stucco
R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.069
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
R-21 Wall
House/Garage Interior Walls Wood Framed Wall 2x6 @ 16 in. O. C.R-21 None / None 0.064
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.4
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: no insul. / 2x4
Attic RoofHouse Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-13 None / 0 0.072
Roofing: 10 PSF (RoofTileAirGap)
Tile Gap: present
Roof Deck: Wood
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Around Roof Joists: R-0.0 insul.
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 11 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total Cavity
R-value
Interior / Exterior
Continuous
R-value
U-factor Assembly Layers
R-0 Garage Ceiling Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4
Inside Finish: Gypsum Board
R-38 Ceiling
w/R-13@Roof.
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025
Over Ceiling Joists: R-28.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
R-21@FAU
w/R-13@Roof.
Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in. O. C.R-21 None / None 0.044
Over Ceiling Joists: R-11.9 insul.
Cavity / Frame: R-9.1 / 2x4
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04 05
Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50
Required Not Required N/A n/a n/a
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Distribution Type Water Heater Name Number of Units Solar Heating
System
Compact
Distribution HERS Verification Water Heater
Name (#)
DHW Sys 1 Domestic Hot
Water (DHW)
HERS Verified Pipe
Insulation credit DHW Heater 1 1 n/a None DHW Sys
1-hers-dhw DHW Heater 1 (1)
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 12 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name
Heating
Element
Type
Tank Type # of Units Tank Vol.
(gal)
Heating
Efficiency
Type
Efficiency Rated Input
Type
Input Rating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff
1st Hr. Rating
or Flow Rate
Tank
Location
DHW
Heater 1 Gas
Consumer
Instantaneo
us
1 0 UEF 0.93 Btu/Hr 200000 0 n/a n/a
WATER HEATING - HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution
Type Recirculation Control Shower Drain Water Heat
Recovery
DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09
Name System Type Heating Unit Name Heating Equipment
Count Cooling Unit Name Cooling Equipment
Count Fan Name Distribution Name Required
Thermostat Type
HVAC1 Heat pump
heating cooling
Heat Pump System
1 2 Heat Pump System
1 2 HVAC Fan 1 Air Distribution
System 1 Setback
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 13 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11 12 13
Name System Type Number of
Units
Heating Cooling
Zonally
Controlled
Compressor
Type HERS VerificationHeating
Efficiency
Type
HSPF/HS
PF2/COP Cap 47 Cap 17
Cooling
Efficiency
Type
SEER/SE
ER2
EER/EER
2/CEER
Heat Pump
System 1 Central split HP 2 HSPF2 7.5 33000 19000 EER2SEER2 14.3 12 Not Zonal Single
Speed
Heat Pump System
1-hers-htpump
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER/EER2 Verified
SEER/SEER2
Verified Refrigerant
Charge
Verified
HSPF/HSPF2
Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Not Required Yes No Yes Yes
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Name Type Design Type
Duct Ins. R-value Duct Location Surface Area
Bypass Duct Duct Leakage HERS Verification
Supply Return Supply Return Supply Return
Air Distribution
System 1
Unconditioned
attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Air Distribution
System 1-hers-dist
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 14 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design Buried Ducts Deeply Buried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
INDOOR AIR QUALITY (IAQ) FANS
01 02 03 04 05 06 07 08 09
Dwelling Unit Airflow (CFM)Fan Efficacy
(W/CFM)IAQ Fan Type
Includes
Heat/Energy
Recovery?
IAQ Recovery
Effectiveness -
SRE/ASRE
Includes Fault
Indicator Display?HERS Verification Status
SFam IAQVentRpt 121 0.35 Exhaust No n/a / n/a No Yes
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E
Project Name:Point Happy - Plan #2 Calculation Date/Time:2023-11-30T13:58:44-08:00 (Page 15 of 15)
Calculation Description:Title 24 Analysis Input File Name:Willms347.ribd22x
Registration Number:Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000
Schema Version: rev 20220901
Report Generated: 2023-11-30 13:59:38
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/ HERS Certification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Rick Maurer
Rick Maurer Title 24, Inc.11/30/2023
7544 E. Saddlehill Trail R19-90-30037
Orange, CA 92869 714-771-1507
Zachary Nordby
Williams Homes, Inc.11/30/2023
24911 Avenue Stanford 734097
Santa Clarita, CA 91355 661-222-9207
423-P010215908A-000-000-0000000-0000 11/30/2023 14:05 CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.