Loading...
BSOL2024-0073BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 02/26/2024 ISSUED DATE: 03/05/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 54160 AVENIDA VALLEJO BSOL2024-0073 774213009 Lot 17 MB 20/50 SANTA CARMELITA VALE LA QUINTA UNIT 26 $8,960.00 RC, 17 Owner:LUIS CERVANTES 54160 AVENIDA VALLEJO, LA QUINTA, CX 92253 Applicant:Adam Fontenot 23885 ENRIQUEZ DRIVE, DIAMOND BAR, CA 91765 Contractor:DAVID JEONG / 1071725 23885 ENRIQUEZ DRIVE, DIAMOND BAR, CA 91765 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/30/25 3:57 pm Page 1 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2024-0073 54160 AVENIDA VALLEJO BUILDING PERMIT application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 9/30/25 3:57 pm Page 2 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2024-0073 54160 AVENIDA VALLEJO BUILDING PERMIT 12.8kW SOLAR ARRAY - (32) 400W VSUN SOLAR VSUN400-144MH PANELS W/ (32) ENPHASE 1Q8PLUS-72-2-US MICROINVERTERS + ENPHASE IQ COMBINER BOX + DERATE MAIN BREAKER TO 175A [640SF] 2022 CALIFORNIA BUILDING CODES. Use of Permit Construction Details ResidentialPV System Type 12.8System Size (kW DC)3PV Strings (EA) 1PV Miscellaneous Equipment EA RCZoning MHDRGeneral Plan Within La Quinta LimitsCity Limits SANTA CARMELITA VALE LA QUINTA UNIT 26 Subdivision Name 17Lot Number 1364.25Lot Size 97970Centerlines Lot 17 MB 20/50 SANTA CARMELITA VALE LA QUINTA UNIT 26 Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00004998 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $45.77 Solar (PV) More than 10kW $45.77 $1.00 Building Standards Administration $1.00 $30.51 Electrical Miscellaneous Apparatus,Conduits,&Co PC $30.51 $8.00 Technology Enhancement Fee $8.00 $7.24 Credit Card Convenience Fee $7.24 $115.94 Permit Issuance $115.94 $30.51 Electrical Miscellaneous Apparatus,Conduits,&Condu $30.51 $45.77 Solar (PV) More than 10kW PC $45.77 $296.74 $296.74 Total for Invoice INV-00004998 Grand Total for Permit $296.74 $296.74 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 02/26/2024 11:09 02/26/2024 11:09 Submittal Document Verification v.1 Generic Action 02/26/2024 11:09 Plan Check v.1 02/26/2024 0:00 03/04/2024 15:38 Building Review (1 Day) v.1 Receive Submittal 02/26/2024 0:00 02/28/2024 9:19 Building Review (1 Day) v.2 Receive Submittal 02/29/2024 0:00 03/04/2024 15:38 Permit Issuance v.1 03/04/2024 15:39 03/05/2024 16:05 Verify Contractor info & Conditions have been met v.1 Generic Action 03/04/2024 15:39 Verify & Invoice Fees v.1 Generic Action 03/05/2024 16:04 Verify Fee Payment & Issue Permit v.1 Generic Action 03/05/2024 16:04 Print, Attach, and Email Building Permit v.1 Create Report 03/05/2024 16:05 03/05/2024 16:05 Solar Inspections v.1 05/15/2024 16:51 Rough Electrical v.1 Inspection Printed: 9/30/25 3:57 pm Page 3 of 4 Permit Type: Permit Number: Property Address: Solar BSOL2024-0073 54160 AVENIDA VALLEJO BUILDING PERMIT Temp Use of Permanent Power v.1 Inspection 05/15/2024 16:51 05/16/2024 13:47 Inspections - Final v.1 05/20/2024 16:46 05/21/2024 12:07 Solar Final v.1 Inspection 05/20/2024 16:46 05/21/2024 12:07 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 9/30/25 3:57 pm Page 4 of 4 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX CODE REFERENCES PROJECT ADDRESS 54160 AVENIDA VALLEJO, LA QUINTA, CA 92253 OWNER:LUIS CERVANTEZ DESIGNER:ESR SCOPE:12.800 kW DC ROOF MOUNT SOLAR PV SYSTEM WITH 32 - VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH 32 - ENPHASE IQ8PLUS-72-2-US MICROINVERTERS HOUSE PHOTO COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 32 MODULES-ROOF MOUNTED - 12.800 kW DC, 9.280 KW AC 54160 AVENIDA VALLEJO, LA QUINTA, CA 92253 PV-1 AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF LA QUINTA ZONING: CITY OF LA QUINTA UTILITY: IMPERIAL IRRIGATION DIS PARCEL ID:774213009 PV-1 COVER SHEET PV-2 PLOT PLAN WITH ROOF PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-5 ATTACHMENT DETAIL PV-5A ATTACHMENT DETAIL-1 PV-6 ELECTRICAL DIAGRAM PV-7 WIRING CALCULATION PV-7A LOAD CALCULATION PV-8 PLACARD PV-9 LABELS PV-10 MICROINVERTERS CHART PV-11+ EQUIPMENT SPECIFICATIONS 1.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE CEC 2022. 3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. 7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. 10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 12.MICROINVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED. 13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [CEC 690.4(C)] 14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. 17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH CEC 690.12 18.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [CEC 690.13(A)] 19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 20.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 22.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. 23.IN ACCORDANCE WITH 2022 CFC 1205.5, 2019 CFC 1204.4, AND 2016 CFC 605.11.2 A CLEAR, BRUSH-FREE AREA OF 10 FEET(3048 MM) SHALL BE REQUIRED FOR GROUND-MOUNTED PHOTOVOLTAIC ARRAYS. PROJECT TO COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE ASCE 7-16 B BSOL2024-0073 12.8kW SOLAR ARRAY - (32) 400W VSUN SOLAR VSUN400-144MH PANELS W/ (32) ENPHASE 1Q8PLUS-72-2-US MICROINVERTERS + ENPHASE IQ COMBINER BOX + DERATE MAIN BREAKER TO 175A [640SF] 2022 CALIFORNIA BUILDING CODES. 03/04/2024 10 2 ' - 1 " 110'-6" 10 2 ' - 1 " 110'-6" MSP UM (E) UTILITY METER/MAIN COMBO 1 PLOT PLAN WITH ROOF PLAN SCALE: 3/32" = 1'-0"PV-2 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PROJECT DESCRIPTION: 32 x VSUN SOLAR VSUN400-144MH 400W MONO MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 12.800 kW DC AC SYSTEM SIZE: 9.280 KW AC PV-2 PLOT PLAN WITH ROOF PLAN EQUIPMENT SUMMARY 32 VSUN SOLAR VSUN400-144MH 400W MONO MODULES 32 ENPHASE IQ8PLUS-72-2-US MICROINVERTERS ROOF ARRAY AREA #1:- 259.20 SQ FT. ROOF ARRAY AREA #2:- 432.00 SQ FT. ROOF #2 (20) VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH ENPHASE IQ8PLUS-72-2-US MICROINVERTERS PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E 1-STORY HOUSE ROOF #1 (12) VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH ENPHASE IQ8PLUS-72-2-US MICROINVERTERS (E) UTILITY METER/MAIN COMBO (E) FENCE (E) GATE (E) CHIMNEY EXISTING DRIVEWAY (E) POOL (E) TREES (E) PATIO AV E N I D A V A L L E J O 03/04/2024 MSP UM 36 ' - 7 " 25 ' - 2 " 3" 6' - 0 " (E) UTILITY METER/MAIN COMBO 3" 28 ' - 1 1 " 6" 3'-5"16'-7" 2'-0" MODULE TYPE, DIMENSIONS & WEIGHT 1 ROOF PLAN & MODULES PV-3 SCALE: 3/32" = 1'-0" ROOF PLAN & MODULES SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT NUMBER OF MODULES = 32 MODULES MODULE TYPE = VSUN SOLAR VSUN400-144MH 400W MONO MODULES MODULE WEIGHT = 50.48 LBS / 22.9 KG. MODULE DIMENSIONS = 78.89" x 39.44" = 21.60 SF 78 . 8 9 " 39.44" PV-3 VSUN SOLAR VSUN400-144MH 400W MODULES LEGENDS - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 12 259.20 570.75 45 #2 20 432.00 677.54 64 TOTAL 32 691.20 2726.34 25 UM MSP - UTILITY METER - MAIN SERVICE PANEL ROOF DESCRIPTION ROOF TYPE S-TILE ROOF ROOF PITCH AZIMUTH TRUSS SIZE TRUSS SPACING #2 22°90°2"X4"24" ROOF DESCRIPTION ROOF TYPE FLAT ROOF ROOF # OF MODULES MODULE PITCH ROOF PITCH AZIMUTH TRUSS SIZE TRUSS SPACING #1 20 10°0°180°2"X4"24" ROOF #2 (20) VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH ENPHASE IQ8PLUS-72-2-US MICROINVERTERS ROOF #1 (12) VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH ENPHASE IQ8PLUS-72-2-US MICROINVERTERS 18" F I R E S E T B A C K 18" F I R E S E T B A C K 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K ROOF #2 ROOF PITCH 0° MODULE PITCH - 10° AZIM. - 180° ROOF #1 PITCH - 22° AZIM. - 90° (E) UTILITY METER/MAIN COMBO (E) CHIMNEY (32) UNIRAC STANDOFF ATTACHMENTS (19) UNIRAC PRO SERIES SOLARHOOK CT5 ATTACHMENTS 36 " F I R E S E T B A C K (N) UNIRAC NXT HORIZON RAIL (TYP.) - TRUSS ROOF ACCESS POINT 03/04/2024 MSP UM CBACD JB JB (E) UTILITY METER/MAIN COMBO 1 ELECTRICAL PLAN PV-4 SCALE: 3/32" = 1'-0" ELECTRICAL PLAN SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PV-4 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 32 VSUN SOLAR VSUN400-144MH 400W MICRO INVERTERS 32 ENPHASE IQ8PLUS-72-2-US MICROINVERTERS JUNCTION BOXES 2 JUNCTION BOXES RAILS 16 UNIRAC NXT HORIZON RAIL MODULE CLAMPS 52 MID MODULE CLAMPS END CLAMPS 24 END CLAMPS / STOPPER SLEEVE ATTACHMENTS 19 UNIRAC PRO SERIES SOLARHOOK CT5 ATTACHMENTS ATTACHMENTS 32 UNIRAC STANDOFF ATTACHMENTS LEGEND - CONDUIT - JUNCTION BOXJB CIRCUIT #1 CIRCUIT LEGENDS CIRCUIT #2 ACD - AC DISCONNECT CB - COMBINER BOX UM MSP - UTILITY METER - MAIN SERVICE PANEL CIRCUIT #3 CIRCUIT #1 (12 MODULES) CIRCUIT #2 (10 MODULES) CIRCUIT #3 (10 MODULES) (N) JUNCTION BOX (TYP.) (N) 3/4" EMT CONDUIT (E) UTILITY METER/MAIN COMBO (N) NON-FUSED AC DISCONNECT (32) ENPHASE IQ8PLUS-72-2-US MICROINVERTER (N) ENPHASE COMBINER BOX 03/04/2024 1 0 ° 7" SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT ATTACHMENT DETAIL PV-5 1 PV-5 1 ATTACHMENT DETAIL (SIDE VIEW) PV-5 SCALE: NTS PV-5 2 ATTACHMENT DETAIL (ENLARGED VIEW) PV-5 SCALE: NTS (2) 5/16" x 3.5" LAG BOLTS W/EMBEDMENT DEPTH 2.5 CHEMLINK E-CURB SYSTEM ROOF DECKING FLASHING SEALANT AROUND PENETRATION UNIRAC STANDOFF NXT HORIZON COMBO CLAMP UNIRAC NXT HORIZON RAIL 5/16"-18"X1"SEPARATED FLANGE HEX SCREW SEE (2/PV-5) FOR ENLARGED VIEW SOLAR PV MODULE UNIRAC TILT LEG ROOF DECKING 03/04/2024 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT ATTACHMENT DETAIL-1 PV-5A 1 ATTACHMENT DETAIL PV-5A 2 1 ATTACHMENT DETAIL PV-5A PV-5A ATTACHMENT DETAIL (ENLARGED VIEW) PV-5A SCALE: N.T.S SCALE: N.T.S 2 (E) S-TILE ROOF AT CONCECTION, TYPICAL OF ALL: 1. REMOVE TILE AND LOCATE RAFTER. 2. ATTACH ALL TILE HOOK PER MFG. INSTRUCTIONS. 3. REPLACE TILES AND NOTCH IF CECESSARY TO ENSURE PROPER FIT.PV MODULE END/MID CLAMP (2) 5/16 X 3" LAG BOLTS W/ EMBEDMENT DEPTH 2.5" NOTE: 1.2" MINIMUM, 10" MAXIMUM BETWEEN ROOF DECK AND MODULES. (E) S-TILE ROOF (N) UNIRAC PRO SERIES SOLARHOOK CT5 ATTACHMENTS (2) 1/4" X 3.5" LAG BOLTS W/ EMBEDMENT DEPTH 2.5" PV MODULE 6 " (N) UNIRAC NXT HORIZON RAIL 03/04/2024 L1 L2 G -+-+ 2 -+ 1 3 = 1 2 ==== BRANCH TERMINATOR (ET-TERM) G N -+-+ 2 -+ 1 3 ===== BRANCH #2 BRANCH #3 L1 L2 20A/2P 20A/2P 9 10 9 10 15A/2P ENPHASE IQ8PLUS-72-2-US MICROINVERTER JUNCTION BOX, 600 V, NEMA 3R, UL LISTED -+-+ -+-+ 3 L1 L2 N G IQ GATEWAY CELL MODEM ENPHASE IQ COMBINER X-IQ-AM1-240-4/4C 120/240VAC, 1ɸ, 3W 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONLY UL 1741 COMPLIANT -+-+ 2 -+ 1 3 ===== BRANCH #1 11 12 -+-+ (32) VSUN SOLAR VSUN400-144MH 400W MONO MODULES 20A/2P L1 L2 LOAD GN VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER LINE GEC G N (N) MAIN BREAKER TO HOUSE 240V, 175A/2P L1 L2 N 4 G 50A/2P NL2L1 TO UTILITY GRID M BI-DIRECTIONAL UTILITY METER #79450040 120/240V 1ɸ, 3-W EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. CEC 250.52, 250.53(A) LOAD SIDE INTERCONNECTION AT MAIN SERVICE PANEL PER ART. 705.12 PV AC DISCONNECT NON-FUSED 240V, 1ɸ, 3W 60A RATED NEMA 3R BACK FEED BREAKER REF 2022 CEC 705.12(B)(3)(2) (E) MAIN SERVICE PANEL, ETON 200A RATED, 240V DERATE MAIN BREAKER FROM 200A TO 175A SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT ELECTRICAL LINE 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS PV-6 DIAGRAM CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (6)CU#12AWG -ENPHASE ENGAGE CABLE (L1 &L2 NO NEUTRAL)N/A N/A (1)CU#6AWG -BARE COPPER IN FREE AIR (6)CU#10AWG -THWN-2 L1 &L2 (1)CU#10AWG -THWN-2 GND (2)THWN-2 L1 &L2 (1)THWN-2 N (1)THWN-2 GND 1 2 3 CU#6AWG - CU#10AWG - CU#6AWG - EMT,LFMC OR PVC IN ATTIC 3/4" EMT,LFMC OR PVC 3/4" (2)THWN-2 L1 &L2 (1)THWN-2 N (1)THWN-2 GND 4 CU#6AWG - CU#10AWG - CU#6AWG -EMT,LFMC OR PVC 3/4" DC SYSTEM SIZE: 12.800 kW DC AC SYSTEM SIZE: 9.280 kW AC (32) VSUN SOLAR VSUN400-144MH 400W MONO MODULES WITH (32) ENPHASE IQ8PLUS-72-2-US MICROINVERTERS (1) BRANCH CIRCUIT OF 12 MODULES AND (2) BRANCH CIRCUITS OF 10 MODULES ARE CONNECTED IN PARALLEL GROUNDING & GENERAL NOTES: 1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCE WITH [CEC 690.43] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOX. DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [CEC 230.67]. THE SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [CEC 705.12], AND [CEC 690.59]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9], [CEC 230.95] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH RACKING NOTES: 1. BOND EVERY OTHER RAIL WITH #6 BARE COPPER 120% RULE CHECK: 120% X 200A = 240A 32 MICRO-INVERTERS X 1.21A X1.25 = 48.4A 240A - 175A = 65A ≥ 48.4A, OKAY 03/04/2024 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT WIRING CALCULATIONS PV-7 ELECTRICAL NOTES PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -5° AMBIENT TEMP (HIGH TEMP 2%)49° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%C SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VSUN SOLAR VSUN400-144MH 400W MODULE VMP 40.7V IMP 9.85A VOC 48.9V ISC 10.33A TEMP. COEFF. VOC -0.29%C MODULE DIMENSION 78.89"L x 39.44"W x 1.57"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US MICROINVERTER MIN/MAX DC VOLT RATING 30V MIN/ 58V MAX MAX INPUT POWER 235W-440W + NOMINAL AC VOLTAGE RATING 240V/ 211-264V MAX AC CURRENT 1.21A MAX MODULES PER CIRCUIT 13 (SINGLE PHASE) MAX OUTPUT POWER 290 VA 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. 03/04/2024 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT LOAD CALCULATIONS PV-7A 03/04/2024 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PV-8 PLACARD LABEL-1: CAUTION: AUTHORIZED SOLAR PERSONNEL ONLY! LABEL LOCATION: AC DISCONNECT WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: CEC 690.13(B) LABEL- 2: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING! LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: CEC 110.27(C) & OSHA 1910.145 (f) (7) LABEL- 4: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: CEC 705.12(D) & CEC 690.59 LABEL- 5: CAUTION! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: CEC 705.12(B)(3)(2) LABEL- 6: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL- 7: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: AC DISCONNECT CODE REF: CEC 690.56(C)(2) LABEL- 8: PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT CODE REF: CEC 690.13(B) LABEL- 9: LABEL- 10: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: CEC 690.54 RATED AC OUTPUT CURRENT PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLATGE 240 V WARNING! POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT) CODE REF: CEC 690.13(B) LABEL- 11: LABEL LOCATION: AC DISCONNECT CODE REF: CEC 690.56(C) & CFC 2022 1205.4.1(1) 38.72 A !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: CEC 705.12(C) & CEC 690.59 LABEL- 3: LABEL LOCATION: MAIN SERVICE PANEL LABEL- 13: WARNING SOURCES UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ! DUAL POWER SUPPLY LABEL- 12: UTILITY PV DISCONNECT SAFETY SWITCH AC DISCONNECT !! LABEL LOCATION: AC DISCONNECT CODE REF: CEC 690.13(B) LABEL- 14: THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO 175 AMPS, DO NOT UPSIZE IT LABEL LOCATION: MAIN SERVICE PANEL 03/04/2024 MSP UM CBACD JB JB SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PV-9 54160 AVENIDA VALLEJO, LA QUINTA, CA 92253 LABELS (N) PV ARRAY (N) JUNCTION BOX (TYP.) (N) AC DISCONNECT (N) ENPHASE COMBINER BOX CAUTION: MULTIPLE SOURCES OF POWER DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: CEC 690.56(A)(B), [CEC 705.10]) LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT CEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2022 CALIFORNIA ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] (E) UTILITY METER/MAIN COMBO 03/04/2024 (E) UTILITY METER/MAIN COMBO SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT PV-10 MICRO INVERTER CHART 1-10 2 3 4 11-20 21-30 31-40 41-50 51-60 5 61-70 6 7 8 9 10 1 MICROINVERTER CHART SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-11 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-12 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-13 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-14 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-15 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-16 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-17 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-18 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-19 SHEET NAME SHEET SIZE SHEET NUMBER LU I S C E R V A N T E Z RE S I D E N C E 54 1 6 0 AV E N I D A V A L L E J O , LA Q U I N T A , CA 9 2 2 5 3 ANSI B 11" X 17" PROJECT NAME & ADDRESS DRAWN BY ESR DATE:02/23/2024 REVDATEDESCRIPTION REVISIONS 230 E OHIO ST #410 CHICAGO, IL 60611 ECO SPARK ENERGY A02/26/2024REVISION B02/29/2024AHJ COMMENT EQUIPMENT SPECIFICATION PV-20