Loading...
BPOL2022-0163BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 04/25/2022 ISSUED DATE: 05/17/2022 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 54160 AVENIDA VALLEJO BPOL2022-0163 774213009 $30,000.00 Owner:Amy Cervantes 54160 avenida vallejo, la quinta, ca 92253 Applicant:V M POOL SERVICES & REPAIR 40395 FIRENZE COURT, INDIO, CA 92203 Contractor:V M POOL SERVICES & REPAIR 40395 FIRENZE COURT, INDIO, CA 92203 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/30/25 3:56 pm Page 1 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2022-0163 54160 AVENIDA VALLEJO BUILDING PERMIT CERVANTES / ADDITION OF SPA TO EXISTING POOL AT REAR YARD *** ADDITION OF SPA TO EXISTING POOL AT REAR YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. Use of Permit Construction Details Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BPOL2022-016 3 $83.37 RE-INSPECTION FEE $83.37 $11.00 RECORDS MANAGEMENT FEE $11.00 $113.38 SWIMMING POOL/SPA/WATER FEATURE PC $113.38 $83.37 RE-INSPECTION FEE $83.37 $208.41 SWIMMING POOL/SPA/WATER FEATURE $208.41 $5.00 TECHNOLOGY ENHANCEMENT FEE $5.00 $2.00 BSAS SB1473 FEE $2.00 $506.53 $506.53 Total for Invoice PERMIT-BPOL2022-0163 Grand Total for Permit $506.53 $506.53 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 04/25/2022 0:00 FINAL** v.4 Inspection FINAL** v.3 Inspection FINAL** v.2 Inspection FINAL** v.1 Inspection PRE-PLASTER v.2 Inspection PRE-PLASTER v.1 Inspection UNDERGROUND GAS v.1 Inspection PRE-GUNITE v.1 Inspection UNDERGROUND ELEC v.1 Inspection UNDERGROUND PLBG v.1 Inspection Printed: 9/30/25 3:56 pm Page 2 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2022-0163 54160 AVENIDA VALLEJO BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 9/30/25 3:56 pm Page 3 of 3 4'4' 10" 51 ' 5' 10' 28 ' 50' 31' 14 ' 20 4 6 8 10 Scale: 3/16" = 1 ft V. M . P O O L S E R V I C E & R E P A I R 40 3 9 5 F I R E N Z E C O U R T IN D I O C A . 9 2 2 0 3 LI C # 9 5 7 5 3 7 SIZE: 7' X 7'AREA: 49 SQ FT. DEPTH: 3'6"JETS: 6 HEIGHT: +18"TILE:TBD PERIMETER:28 FT.GAL: 546 SPA SPECS 1- PENTAIR VSF FILTER PUMP 1- PENTAIR MASTERTEMP 300,000 BTU HEATER 1- PENTAIR CLEAN & CLEAR 320 SQ. FT. FILTER POOL EQUIPMENT DECK TYPE :BRUSH GRAY CONCRETE RAISE POST : CONCRETE AREA:TBD TANNINGV SHELF DEPTH: N/A TANNING SHELF : N/A DECK RETURNS: 2 SKIMMER: 1 POOL MAIN DRAIN: 2 VAC LINE: 1 WATER FEATURE :1 PVC: 2" SCHEDULE 40 GAS LINE:POLY PIPE 1.5" PLUMBING SIZE: 14' X 31'AREA: 455 SQ FT. DEPTH: 3' X 66'SKIMMER: 1 RETURNS: 3 TILE:TBD PERIMETER: 79 FT.GAL: 9963 POOL SPECS NAME: AMY CERVANTES Address:54160 AVENIDA VALLEJOS CITY: LA QUINTA ST: CA ZIP: 92253 OWNER 170 LF of 1" Electrical Conduit from Main Panel to Equipment Panel 170 LF of 2" Polypropylene Gas Pipe to Pool Heater LED Pool Lights #8 Bare Bonding Wire Around Pool& Spa -9" W.D. -5'6" W.D. -3'6" W.D. Gas Meter New Tanning Shelf 5'0" x 9'0" -9" W.D. with an Umbrella Sleeve Existing Planters to Remain Digging Access Flood Water Drainage to be Connected to Existing Drains 2'6"' x 5' fire Pit with Stucco Finish Existing A/C Units Properly Line 6' Block Wall P/L Skimmer and Autofill New Raised Spa +18" 7' x 7' with 6 Therapy Jets Self Latching/Closing Door 4' Pool Equipment block wall PCO W//(E) GAS METER BY SOCAL GAS CO. 40AMP Pool Sub-Panel Existing Pool Equipment Location Split Main Drains 3' Apart with Anti-vortex 10" ASME/ANSI RESIDENCE PATIO COVER Existing 200AMP Main Electrical Panel Flood Water Drainage to be Connected to Existing Drains 6' Block Wall P/L Self Latching/Closing Door Existing BBQ Island to be Remove Brush Gray Finish Concrete Brush Gray Finish Concrete WI L L I A M S P O O L S P E C I A L I S T P. O . B O X 1 6 2 5 IN D I O C A . 9 2 2 0 2 LI C # 1 0 7 0 2 0 9 INSTALLATION OF THE POOL SYSTEM AND EQUIPMENT WILL COMPLY WITH SECTION 114- MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATER, POOL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURES RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS SPA TO BE EQUIPPED WITH ANTI-ENTRAPMENT DEVICE (SEC.1404 FEDERAL SWIMMING POOL AND SPA DRAIN COVER STANDARD) PROVIDE LOCATION OF ANTI-ENTRAPMENT/VORTEX COVERS MEETING CURRENT STANDARS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS(ASTM) OR THE AMERICAN SOCIETY MECHANICAL ENGINEERS( ASME) IDENTIFY A MINIMUN 3 FEET SEPARATION BETWEEN ALL DRAINS AND NOTE HYDRAULICALLY BALANCED SAFETY FEATURES: ALL ANTI-ETRAPMENT COVER INSTALLATION MEETING CURRENT STANDARD OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGENEERS(ASME) ELECTRICAL : EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELLIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26 BUILDING CODES: 2019 California Residential Based on 2015 International Residential Code (IRC) 2019 California Electrical Code Based on 2014 National Electrical Code (NEC) 2019 California Mechanical Based on 2015 Uniform Mechanical Code (UMC) 2019 California Plumbing Code Based on 2015 Uniform Plumbing Code (UPC) 2019 California Green Code California Building Standard Commission 2019 California Energy Code California Energy Commission NOTES : 1. ALL EQUIPMENT WILL BE SEISMICALLY ANCHORED 2. ALL GFI OUTLETS WILL BE WEATHER AND TAMPER PROOF 3. ALL OUTLETS SUPPLIED BY SINGLE PHASE. 15A AND 20A . 125V OR 240V BRANCH CIRCUITS FOR SWIMMING POOL PUMP 4. PROVIDE 36" WORKING CLEARANCE FOR POOL EQUIPMENT 5. POOL SAFETY BARRIERS EXIT DOORS ALARMS SELF CLOSING SELF LATCHING DOORS 6. POOL AND SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART ANTI-COVERS 10" ASME/ANSI APPROVED EXISTING POOL 3'3'3'3' Self Latching/Closing Door AVENIDA VALLEJOS N 2" PVC Plumbing 640-F SITE PLAN REVIEWEDfor conformance to structural details Matthew G. Thompson Pool Engineering, Inc. Structural details shall take precedence over conflicts with site plan. Authentication Code = dg#22-05312@9%33a041222 54160 AVENIDA VALLEJO BPOL2022-0163 - 54160 AVENIDA VALLEJO CERVANTES / ADDITION OF SPA TO EXISTING POOL AT REAR YARD ADDITION OF SPA TO EXISTING POOL AT REAR YARD [POOL ENGINEERING]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODES. 05/12/2022 Safety Features – New pools and spas shall be equipped with at least two of the following drowning prevention safety features. (H&S § 115922 – SB No. 442) • Enclosure that isolates the pool or spa from dwelling. • Removable Mesh fencing, a gate that is self-latching and closing and can accommodate a key lockable device. • Safety pool cover. • Exit alarms on doors that provide direct access to pool or spa. • A self-closing self latching device placed on doors providing direct access to pool or spa. • An alarm that when placed in a pool or spa, will sound upon detection. (Surface Motion, Pressure, Sonar, Laser) 05/12/2022 05/12/2022