Loading...
BSOL2024-0116DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Permit Number: Property Address APN: Legal Description Property Zoning: Valuation: Solar BSOL2024-0116 57695 SALIDA DEL SOL 762490047 Lot 47 MB 416/69 TR 34243 RL, 47 $20,000.00 BUILDING PERMIT eca Qa�&a CALIFORNIA Owner: Applicant: PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 04/08/2024 ISSUED DATE: 04/22/2024 Daniel Marks HOT PURPLE INC DBA HOT PURPLE ENERGY P O BOX 261, PALM SPRINGS, CA 92263 Contractor: HOT PURPLE INC DBA HOT PURPLE ENERGY / 940550 P O BOX 261, PALM SPRINGS, CA 92263 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 10/7/25 8:32 am Page 1 of 3 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2024-0116 Property Address: 57695 SALIDA DEL SOL INSTALLATION OF TESLA ENERGY STORAGE SYSTEM TO BE INTERCONNECTED WITH EXISTING 9.81kW PV SOLAR SYSTEM. (2) NE TESLA POWERWALL 3 UNITS, (1) TESLA BACKUP GATEWAY 2 PCS + (1) 125A BACKUP LOADS PANEL. THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF OR ALTERATION TO QUANTITY OF EXISTING PV MODULES. [2022 CALIFORNIA BUILDING CODES] PV System Type Residential System Size (kW DC) 9.8 PV Strings (EA) 4 PV Miscellaneous 3 Zoning RL General Plan LDR Equipment EA City Limits Within La Quinta Limits Subdivision Name TR 34243 Lot Number 47 Lot Size 1187.87 Centerlines 92316 Legal Description Lot 47 MB 416/69 TR 34243 Type Group Sq Ft Value Invoice No. Fee INV-00005967 Solar (PV) Less than 10kW Permit Issuance Electrical Miscellaneous Apparatus,Conduits,&Condu Digital Archiving and Records Management Fee - OTC Solar (PV) Less than 10kW PC Credit Card Convenience Fee Technology Enhancement Fee Building Standards Administration Electrical Miscellaneous Apparatus,Conduits,&Co PC Fee Amount $30.51 $115.94 $91.53 $12.00 $30.51 $9.53 $8.00 $1.00 $91.53 Total for Invoice INV-00005967 $390.55 Amount Paid $30.51 $115.94 $91.53 $12.00 $30.51 $9.53 $8.00 $1.00 $91.53 $390.55 Grand Total for Permit $390.55 $390.55 Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 04/08/2024 16:46 04/08/2024 16:46 ---------------------------------------------------------------------------------------------------------------------------------------- Submittal Document Verification v.1 Generic Action 04/08/2024 16:46 Plan Check v.1 04/08/2024 0:00 04/16/2024 16:32 ---------------------------------------------------------------------------------------------------------------------------------------- Building Review (1 Day) v.1 Receive Submittal 04/08/2024 0:00 04/16/2024 16:32 Permit Issuance v.1 04/16/2024 16:33 04/22/2024 16:40 ----------------------------------------------------- Verify Contractor info & Conditions have been met v.1 Generic Action 04/16/2024 16:33 ........................................................................................................................................ Verify & Invoice Fees v.1 Generic Action 04/16/2024 16:33 ------------------------------------------------- Verify Fee Payment & Issue Permit v.1 Generic Action ...................... 04/22/2024 16:40 ---------------------------------------------------------------------------------------------------------------------------------------- Print, Attach, and Email Building Permit v.1 Create Report 04/22/2024 16:40 04/22/2024 16:40 Solar Inspections v.1 ---------------------------------------------------------------------------------------------------------------------------------------- Rough Electrical v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 04/30/2024 0:00 05/03/2024 12:01 Printed: 10/7/25 8:32 am Page 2 of 3 BUILDING PERMIT Permit Type: Solar Permit Number: BSOL2024-0116 Property Address: 57695 SALIDA DEL SOL Solar Final v.1 Inspection 04/30/2024 0:00 05/03/2024 12:01 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 10/7/25 8:32 am Page 3 of 3 IM4>4** CPE I BSOL2024-0116 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE 0A,04/16/2024 , j MCPHERSON ENGINEERING Structural Analysis Report For BATTERY MOUTING At The MARKS Residence 57695 SALIDA DEL SOL LA QU I NTA, CA 92253 F E C r � J . 82088 [A^ x .03/31/2 \TF Of CAL�F��/ Digitally sealed by RJM on 4/5/24 Designed in Accordance with CBC 2022, ASCE 7-16 Date: 4/5/24 Job #: 24-02363 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave Jurupa Valley, CA 92509 Mobile: (909) 566-0066 Email: SE@mcpe.group 04/05/2024 ©McPherson Engineering Page 1 of 5 McPherson Engineering Battery/Stud Wall Check By: E.C. PROPERTIES: hmax:= 9ft SP := 16in max. stud height spacing of studs SEISMIC LOADS: ASCE 7-16 Seismic Ground Motion Values Site Class := D Site Class (Section 11.4.2) S,:= 1.5 Short -period Spectral Response Acceleration 51:= 0.6 1-Sec Period Spectral Response Acceleration Wpw,w1:= 4001b maxweight of batterypack Fa:= 1.2 TABLE 11.4-1 F,:= 1.7 TABLE 11.4-2 SDS := 3 • Fa SS SDS = 1.2 Short Period Design Spectral Acceleration Parameter (Eq.11.4-3) SDI := 3 FV SI SDI = 0.7 1-Sec Period Design Spectral Acceleration Parameter (Eq. 11.4-4) ASCE 7-16Section 13.6 Mechanical and Electrical Components: ap:= 1 Rp:= 2.5 Qo:= 1.5 Table13.6-1 Ip:= 1 Section13.1.3 z : = 4.5 = 4.5 h : = 15 = 15 Wp : = Wpwrwl = 400 lb 0.4• ap SDS' Wp FP := I + 2 z I Fp max := 1.6' SDS' 1p' Wpwrwl = 768 lb RP) It Ip J / Fp_mi,, := 0.3• SDS' 1p' Wpwrwl = 144 lb FP = 144lb design seismic force STUD LOADING: DLr:= 20psf roofdeadload LLr:= 20psf roof live load DL:= Opsf floordeadload LL:= Opsf floorliveload DLL,:= 15psf wall dead load Wdl r:= DLr trib_w• SP = 333.3lb I'll r := LLr trib_w• SP = 333.3 lb Wd1 := DL• trib_w• SP = 0 wll : = LL• trib_w• SP = 0 w,l:= DLL; 2hmax SP = 360lb trib_w:= 12.50ft maximum tributarywidth of framing on wall FP maximum lateral seismicforce Vmax:= 2 = 721b (2studs required formounting) Wwl + Wdl + Wdl r = 693.3lb (ENERCALC INPUT -STUD CHECK) 04/05/2024 ©McPherson Engineering Page 2 of 5 McPherson Engineering Battery/Stud Wall Check By: E.C. ATTACHMENT TO WOOD WALL: D:= 1in diam.ofscrew 4 FP = 36 lb withdrawl force of4lag bolts NOlags lb Nolags:= 4 number of lags W := 258 — pounds per inch of thread penetration (Table 12.2A NDS) in p := 1.5in thr'd length of screw Fa:= Wp = 387lb 211 = 1501b D = 6 p Fa FOlags _ 10.8 > 1.0 Zll' 88. D NOlags _ 1.1 > 1.0 reduce lag shearcapacity byfor embed. depth WP USE (4)1/4" LAG BOLTS WITH 1.5" MIN. PENETRATION TO (E) STUDS, combined withdrawal and shear loading condition is OK by inspection UNLOADED EDGE DISTANCE: Lagdiam 4 in diam. of screw Dedge 1.5• Lagdiam Dedge = 0.4- in Required edge distance PER NDS2018TABLE 12.5.1E 2' Dedge + Lagdiam = 1• in Total width required Unloaded edge condition based on drywal I, pla ster, or plywood wa I Is utilized for stabilizing wea k axi s bending on studs USE 2xSTUD MINIMUM STUD CONNECTION @ TOP/BOTTOM PLATE: Z:= 1411b NDSTablell-N, for linSide Member Penetration w/16dCommon Toe -Nails Ctn:= 0.83 Toe -Nail factor(NDS11.5.4) Z':= Z•Ctn Z'= 1171b Nonails 2 Typical number of nails used for studtotop/bottom plate Za:= Z'•Nonails Za=234.1lb Shear capacityfor(2)16doommontoenails Rstud 161b Reaction per enercalc stud check Rstud _ 0.07 < 1.0 Za 04/05/2024 ©McPherson Engineering Page 3 of 5 Wood Column Project File: wall stud check_backup_1.ec6 LIC# : KW-06013840, Build:20.23.08.30 McPherson Engineering (c) ENERCALC INC 1983-2023 DESCRIPTION: stud check Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2012 General Information Analysis Method Allowable Stress Design Wood Section Name 2x4 End Fixities Top Free, Bottom Fixed Wood Grading/Manuf. Graded Lumber Overall Column Height 9 ft Wood Member Type Sawn (Used for non -slender calculations) Exact Width 1.50 In Allow Stress Modification Factors Wood Species Douglas Fir - Larch Exact Depth 3.50 in Cf or Cv for Bending 1.50 Wood Grade No.2 Area 5.250 in^2 Cf or Cv for Compressioi 1.150 Fb + 900.0 psi Fv 180.0 psi Ix 5.359 in^4 Cf or Cv for Tension 1.50 Fb - 900.0 psi Ft 575.0 psi ly 09844 in Cm :Wet Use Factor 1.0 . Fc - Prll 1,350.0 psi Density 31.20 pcf Ct : Temperature Faci 1.0 Fc - Per p 625.0 psi Cfu :Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf :Built-up columns 1.0 Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr: Repetitive ? No Minimum 580.0 580.0 Column Buckling Condition: Fully braced against buckling ABOUT X-X Axis Fully braced against buckling ABOUT Y-Y Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 10.238 Ibs Dead Load Factor AXIAL LOADS ... Gravity: Axial Load at 9.0 ft, D = 0.6930, Lr = 0.3330 k BENDING LOADS ... Battery: Lat. Point Load at 4.50 ft creating Mx-x, E = 0.0720 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.7082 : 1 Maximum SERVICE Lateral Load Reactions. . Load Combination +D+0.70E Top along Y-1 0.0510 k Bottom along Y-Y 0.0720 k Governing NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Top along X-)� 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are . Along Y-Y 1.097 in at 9.0 ft above base Applied Axial 0.7032 k for load combination : E Only Applied Mx -0.2268 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 1,552.50 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.080 : 1 Bendina Compression Tension Load Combination +D+0.70E Location of max.above base 4.470 ft Applied Design Shear 21.60 psi Allowable Shear 180.0 psi Load Combination Results Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination CD C P Stress Ratio Status Location Stress Ratio Status Location D Only 1.000 1.000 0.08628 PASS O.Oft 0.0 PASS 9.0 ft +D+Lr 1.000 1.000 0.1271 PASS 0.0 ft 0.0 PASS 9.0 ft +D+0.750Lr 1.000 1.000 0.1169 PASS O.Oft 0.0 PASS 9.0 ft +D+0.70E 1.000 1.000 0.7082 PASS 0.0ft 0.080 PASS 4.470ft +D+0.5250E 1.000 1.000 0.5330 PASS O.Oft 0.060 PASS 4.470ft +0.60D 1.000 1.000 0.05177 PASS 0.0 ft 0.0 PASS 9.0 ft +0.60D+0.70E 1.000 1.000 0.7034 PASS O.Oft 0.080 PASS 4.470ft 04/05/2024 ©McPherson Engineering Page 4 of 5 Wood Column . _ Project File: wall stud check_backup_1.ec6 DESCRIPTION: stud check Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 0.051 0.703 +D+Lr 0.051 1.036 +D+0.750Lr 0.051 0.953 +D+0.70E 0.050 0.051 0.703 0.227 +D+0.5250E 0.038 0.051 0.703 0.170 +0.60D 0.051 0.422 +0.60D+0.70E 0.050 0.051 0.422 0.227 Lr Only 0.051 0.333 E Only 0.072 0.051 0.324 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000ft 0.000 in 0.000ft +D+Lr 0.0000 in 0.000ft 0.000 in 0.000ft +D+0.750Lr 0.0000in 0.000ft 0.000 in 0.000ft +D+0.70E 0.0000in 0.000ft 0.768in 9.000ft +D+0.5250E 0.0000in 0.000ft 0.576in 9.000ft +0.60D 0.0000in 0.000ft 0.000 in 0.000ft +0.60D+0.70E 0.0000in 0.000ft 0.768in 9.000ft Lr Only 0.0000in 0.000ft 0.000 in 0.000ft EOnly 0.0000in 0.000ft 1.089in 8.940ft Sketches +X Load 1 JI i i + 0M 2 i; 4 1.50 in 04/05/2024 ©McPherson Engineering Page 5 of 5 Revisions: Date: Jim ti r I GENERAL NOTES: Fin T)• A BSOL2024-0116 %14 INSTALLATION OF TESLA ENERGY STORAGE SYSTEM TO BE INTERCONNECTED WITH EXISTING 9.81 kW PV SOLAR SYSTEM. (2) NEW TESLA POWERWALL 3 UNITS, (1) TESLA BACKUP GATEWAY 2 PCS + (1) 125A BACKUP LOADS PANEL. THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF OR i- ALTERATION TO QUANTITY OF EXISTING PV MODULES. [2022 CALIFORNIA BUILDING CODES] 0 A CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE04/16/2024 BY ii- 1 . ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. 2. ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. 3. THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. 4. PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. 5. THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PHOTOVOLTAIC SYSTEM OR INSTALLATION. 6. ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. 7. ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. 8. TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE 57743 DESCRIPTION OF WORK: 'r 70.1 $7684 5774C INSTALLATION OF NEW TESLA BATTERY BACKUP SYSTEM TO BE INTERCONNECTED WITH AN EXISTING SUNPOWER PV SOLAR SYSTEM (9.8kW). Construction Is NOT PERMITTED CONSTRUCTION HOURS INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: in the fd owing code Hoiida MondayOclDbe, -Friday 30 Ys Monday - st -Ap 7 00 a m to 5 30 p m. CEC 2022 - ARTICLE 690, 705,706 AND OTHERS New Year`s Day CPC 2022 Dr. Martin Luther King Jr. Day C BC 2022 President's Day CMC 2022 Memonal Day CFC 2022 Independence Day Labor Day CRC 2022 veteran's Day LA QUINTA MUNICIPAL CODE Thanksgiving Day Christmas DRAWING SHEETS: COVER SHEET PV-0.0 OPTIMIZER STRINGING NOTES INOTFORPERMITTINOi PV-0.0 (2) SITE PLAN PV-1.0 SINGLE LINE DIAGRAM PV-2.0 WARNING LABELING PV-3.0 SPECIFICATION SHEETS: SPR-E20-327 MODULE TESLA POWERWALL THREE & TESLA 11500 INVERTER TESLA GATEWAY - UL1741 PCS HD6135FB HEAT DETECTOR SPEC SHEET Saturday : &00 a m. to 5:00 p m. Sunday :None Govemmert Code Holidays None May 1 st - September 30th Monday - Friday 6:00 a.m. to 7:00 p.m. Saturday : 1100 a m to 5,0o p m Sunday :None Government Code Holidays- None -AN ADEQUATELY SIZED DEBRIS CONTAINER IS REQUIRED ON THE JOB SITE DURING ALL PHASES OF CONSTRUCTION AND MUST BE EMPTIED AS NECESSARY. FAILURE TO DO SO MAY CAUSE THE CITY TO HAVE THE CONTAINER DUMPED AT THE EXPENSE OF THE OWNER / CONTRACTOR.' �O PROF ESS /p/` . McpyF� IOU No.82088 y z /26 \TF of CA1 This item has been digitally signed and sealed on Apr 05, 2024 Michael Rango MLc ja 12avtgo- 760.322.4433 Lic. C46 - No. 940550 m a) (I) N .0 i M Q oQM o vi d LL Z. In CI) O C _ C O Jco a� N U 6''j^^_ LU W CO W Cl)N M U CU v/ L CC� \ O U U L CO C) G Lj J Drawn by Checked by: MJR Date: 4/1 /2024 Scale: NTS Job Number: 15001 Sheet Number PV-0.0 Sheet OPTIMIZER /STRINGING (INSTALLATION NOTES NOT FOR PERMITTING) INVERTER 1 - STRING 1 - 8 MODULES sL INVERTER 2 - STRING STRING sunpower PROFESS/o/ J. McpyF', s 2 No.82088 /26 \TF OF CA\ -\FOB/ This item has been digitally signed and sealed on Apr 05, 2024 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Dm04/1612024 By--,'LF SPECIAL NOTE FOR ESS SYSTEMS:' 1206.11.6 OF THE CALIFORNIA STATE AMENDMENTS STATES THAT A SMOKE ALARM OR HEAT ALARM SHALL BE INSTALLED IN THE VICINITY OF THE BATTERY SYSTEM. (HEAT ALARMS SHALL BE USED WHERE SMOKE ALARMS CANNOT BE USED BASED ON THEIR LISTING - INSIDE A GARAGE.) HEAT ALARMS SHALL BE INTERCONNECTED WITH THE HOME SMOKE ALARM. 1206.4.5 WHERE ESS ARE SUBJECT TO IMPACT BY A MOTOR VEHICLE IMPACT PROTECTION SHALL BE PROVIDED BY THE INSTALLATION OF SAFETY BOLLARDS IN FRONT OF ESS. L- 0' 7.5' 15' 30' (E)30 SPR—E20-327 (9.8kW) SOLAR PANELS PROPERTY LINE 2.2 /� 2.1 I I I I I I I I PROPERTY LINE SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 225A MAIN ELECTRICAL PANEL 1.2 SUBPANEL NEW ELECTRICAL (ADJACENT TO MSP) 2.1 SYSTEM AC DISCONNECT 2.2 ESS SAFETY DISCONNECT NEW ELECTRICAL (INSIDE GARAGE) 2.3 TESLA GATEWAY/GENERATION PANEL 2.4 BU/CRITICAL LOADS PANEL 2.5 TESLA POWERWALL THREE (x2) 2.6 HEAT DETECTOR SITE LEGEND ----__= EAVESETBACK/WALL WORKING CLEARANCES SHALL BE PROVIDED AROUND ALL EQUIPMENT PER CEC 110.26 Michael Rango M%chaeLRan jo- 760.322.4433 Lic. C46 - No. 940550 N U O O U U N N > C\l t CD21 T T 2) C) O ❑ Q M 2 U C U v auji (M z 0-0- ILL C N Q) Z C2 cc) 0 11 !L C7 U) _ _o O O C] J to . � o � W U � O M Ln .2 Z Q Q CITY OF LA QUINTA U BUILDING DIVISION REVIEWED FOR CODE LUI j) COMPLIANCE i c C) D1104/16/2024 CC G ti M LO J Drawn by: SF Checked by: MJR Date: QROF ESS /0,14` 4/1 /2024 McP Scale: No. a2oss ill = 15' Job Number: /26 * 15001 (P C I V qTF Sheet Number: OF C PV-1.0 This item has been digitally signed and sealed on Apr 05, 2024 Sheet 12'-6" MAX. TRIBUTARY WIDTH OF ROOF & FLOOR ABOVE OPTION 1: HANGER OPTION 2: HANGER zJM REL DIRECTLY TO STUD INSTALLED BETWEEN STUDS W/ BLKG McPHERSON ENGINEERING RYAN JAMES McPHERSON, P.E. E DBL 2x TOP PLATE 9240 LIMONITE AVE, ( ) JURUPA VALLEY, CA 92509 566-0066 (N) BATTERY i @M PE.GRO (E) 2x STUDS @ 16" D.C. SEQMCPE.GROUP (MAX. WT.: 400#) (4) Y ILAG SCREWS W/ MIN. (2)16d W/ 1/ MIN. EMBED COMMON TOENAILS PROJECT LOCATION: TO TOP/BOTTOM F1 PLATE THE MARKS (N) BATTERY RESIDENCE (MAX. WT.: 400#) 57695 SLAIDA DEL SOL, LA QUINTA, CA 92253 (4) %" LAG SCREWS W/ 1Y2" MIN. EMBED PROJECT DESCRIPTION: x BATTERY WALL u 2x4 BLK'G WHERE REQ'D MOUNT x W/ SIMPSON'A35' CLIP EA. SIDE o � (4) �" LAG SCREWS SHEET DESCRIPTION: W/ 1%" MIN. EMBED 2x4 BLK'G WHERE REQ'D z W/ SIMPSON'A35' CLIP EA. SIDE (E) WALLS SHALL HAVE %" DETAILS PLYWOOD, Y2" DRYWALL OR %" STUCCO E.O.R. (E) 2x4 S1 UDS @ 16" O.C., QROFESS/O/ TYP. McPy�� No.82088 (E) SILL PLATE /26 qTF OF CAv-�FO�� •�. , ' .�'a .' .... .ate. ` •"" .�• a .:. . �. d.: . 'b. „ ,..; 'a• This item has been digitally signed T ' +b' :a :. : JEJ— _ and sealed on Apr 05, 2024 ;III —III I I -III —III— CITY OF LA QUINTA =III —I III —I I BUILDING DIVISION DATE: 4/05/24 REVIEWED FOR M I I I M CODE SCALE: N.T.S I COMPLIANCE I PROJECT #: 24-02363 a„ F04/16/2024 ay—a� SHEET #: S-1 E SCALE: SCALE: Q N.T.S. � TYP. NOTES &SPECS N.T.S. EQUIPMENT WALL MOUNT ell rnN 111 N'TnRQ QNAI I RF rnpprR I ]NI FQC 0TF6RW lfrn SPrrrl rn ** EXISTING PHOTOVOLTAIC ARRAY ** 9,810 WATT DC (8,860 WATT AC) INDIVIDUAL MODULE RATING: SOLAR ELECTRIC ARRAY PTC = 302.9 WATTS 30 SUNPOWER 327 WATT MODULES Voc = 64.9 VDC MODEL NO. SPR-E20-327 Isc = 6.46 AMPS 30 x 302.9 PTC x 97.5°% EFF = 8.860 kW AC WIRE WIRE TEMP WIRE WIRE WIRE WIRE CONDUCT MI.T1- REO. GND COND. CONDUIT D WIRE AND CONDUIT SCHEDULE AMPS DUER AMPS GI/AGE AMPS DERATF DEFLATE COLUMN AMPS TYPE SIZE ONTY FILL SIZE CONOUITTY PE 90C 9DC FACTOR AMPS 75C 75C USED FACTOR A MODULE TOJ-BOX 1CL35 1.56 16,15 10 40 M71 28.4 35 RHW-2 6 2 1 NA FREE AIR 8 J-SOXTOINVERTER 11135 1.56 16.15 10 40 0.82 36.4 10 35 THWN-2 8 2 1 OS METALLIC C POWERWALL THREE TO GENERATION PANEL 48 1.25 6Q00 6 75 D.82 61.50 6 65 THINVN-2 8 3 1 Q75 METALLIC D BU LOADS PANEL TO GATEWAY 12S 1 125.DO 1/0 170 Rffi 139.40 1/0 150 THWN-2 6 3 1 1 L50 METALLIC E GATEWAY TO MSP LTS 1 US.00 1/0 1 170 0.ffi 1 139.40 1 LSO THWN-2 6 3 1 LSO I METALLIC •• CS VALUES ACCOUNT FOR 125%CLOUD ENHANCEMENT(NEC 6901RAI(1)) CONDUCTORS SIZED FOR BU/CRITICAL LOADS PANEL 1 STRING OF (7) & 1 STRING OF (8) INVERTER ONE J-BOX O 1 1 0 2 0 0 0 3 0 4 0 0 0 5 ° 6 7 1 0 1 0 0-0 O CT­O-0 ME ER C - + - +III - + - + - + - + - + 1 o CT'o-0 MCI MCI MCI MCI AC OUT O Cr-0-0 EXTERIOR 0-0 BESS SWITCH (LOCKABLE) TNN L Pa O MCI (MID CIRCUIT INTERRUPTERS) ONE AT THE BEGINNINGS IF EACH STRING, ONE BETWEEN EVERY (2) MODULES. O-0 o-0 ONE AT THE BEGINNINGS OF EACH STRING, ONE BETWEEN EVERY (2) MODULES. + - + - + - +OI o-0 �0--0 TESLA POWERWALL 3 MCIMCI O �O O USABLE ENERGY 13.5kwh T.RCUI+TRS) +-+ -+-+oCT-O-0 noo MAX OUTPUT 11.5kW POWER FACTOR+/-o.ss 0 0 0 36 0 0 7 0 8 0 �o-0 1707000-xx-v2 POWERWALL THREE = 48Ax1.25 = 60A POWERWALL THREE = 48Ax1.25 = 60A TOTAL = 96A x 1.25 = 120A -I- 1 STRING OF (7) & 1 STRING OF (8) --------------------------------- 1 1 0 1 2 10 °° 1 3 1 0 1 4 10 °° 1 5 10 1 6 -I I+ m -I L+__-J I -I L+--I L+___J I -I L MCI (MID CIRCUIT INTERRUPTERS) ONE AT THE BEGINNINGS IF EACH STRING, ONE BETWEEN EVERY (2) MODULES. MCI (MID CIRCUIT INTERRUPTERS) ONE AT THE BEGINNINGS OF EACH STRING, ONE BETWEEN EVERY (2) MODULES. MCI A -1 J-BOX B INVERTER TWO -L o o-0 7 o 0 (1-0-0 ESS METER - O �o-0 MCI L AC OUT O o- c 0 EXTERIOR O-O o-0 o-0 o-0 BESS SWITCH (LOCKABLE) I I Ta5 L P5 O I I - + - + O1 cr-0--0 TESLA POWERWALL 3 O -o USABLE ENERGY wh - + - + MAX OUTPUT 11.5k13.5kW 0 c /oo-0 POWERFACTOR +/-0.8 +/- o.ss 0 1 cr-0-0 1707000-xx- 0 2 0 0 0 3 0 L4j 0 0 0 06 0 0 7 o 8/-J _j --- ---- ---------01�j --- --- ----- --� -- --� 125A BREAKER (N) BU CRITICAL LOADS PANEL 125A BUSS, 120/24OV, 1 PH, 3W TESLA GATEWAY 2 TPN #1232100-xx x GENERATION QROFESS /p�� J . MCP lip 2 m No.82088 CA /26 1 T PCS CONTROLLED PANEL CURRENT: 200A THE PANEL CURRENT IS CONTROLLED FROM ALL SOURCES INCLUDING THE GRID NOT TO EXCEED THE RATING OF THE BUSBAR NEC 705.13 (B) The sum of all PCS-controlled currents plus all monitored currents of other sources of supply shall not exceed the ampacity of any busbar or conductor supplied by the power production sources. Where the PCS is connected to an over current devise protecting any busbar or conductor not monitored by the PCS the setting of the PCS conrroller shall be set within the rating of that overcurent devise. (N) ESS DISCONNECT (RAPID SHUTDOWN) ADJACENT TO MSP N.C. COM WIRE (CAT 5) N.C. CONTACT w.ba Ess PCS METER - CONTROLLED + PANEL I I CURRENT 0 GATEWAY 2 INTERNAL PANEL 200A BUSS, 120/24OV, 1 PH, 3W [200A] O PCS CONTROLLED PANEL CURRENT: 200A THE PANEL CURRENT IS CONTROLLED FROM ALL SOURCES INCLUDING THE GRID NOT TO EXCEED THE RATING OF THE BUSBAR NEC 705.13 (B) O WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR O (,' / V `� NOTES: EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690,705, 706 AND OTHERS. 7. ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBI ANYONE OTHER THAN QUALIFIED PERSONS. EQUIPMENT8. ALL PV SYSTEM LISTED q�, ��\P F 1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A 9. ALL EXTERIOR IRRIING MATERIAL AL SHALL BE SUITABLE OR A SUNK EXPOSURE AND WET LOCATIONS. OF PHOTOVOLTAIC DISCONNECT. 10. REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT 2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH CIRCUIT CONDUCTOR. TERMINALS -TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" 11. CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. 12. ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2O22 CALIFORNIA ELECTRIC CODE & NEC 2023 705.13. This item has been digitally Signed INVERTER OUTPUT VOLTAGE 13. BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. and Sealed On Apr O5, 2024 4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER 14. ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFCI PROTECTION. p NEC 690-64(b)7. 15. WORKING CLEARANCES SHALL BE PROVIDED PER CEC 110.26 5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE. 16. WHEN A BACKFED BREAKER IS THE METHODS OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD 6. ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. PER CEC 690.13(F)(2) 17. ROOFTOP CONDUIT SHALL BE INSTALLED A MINIMUM OF 7/8" ABOVE THE ROOFTOP. 1707000-xx-y TESLA POWERWALL 3 GRID -TIE PV/BATTERY INVERTER PV INPUT: 60 TO 550 VDC OUTPUT: 11500 WATTS SIX MPPT INPUTS ROUND TRIP EFFICIENCY: 89% 240 VAC, 48 AMPS MAX INTEGRATED GFCI AND DC DISCONNECTS SYSTEM DISCONNECT ADJACENT TO MSP 20OA/240V 125A C47 (E) MAIN SERVICE PANEL 225A BUSS, 120/24OV, 1 PH, 3W ®J N nLo [N) 125A MSP EXISTING AC GROUNDING ELECTRODE CONDUCTOR PROVIDE NEW ELECTRODE IF NOT EXISTING PER CEC 250.53 (A) (2) CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DIE04/16/2024 BY _� r G 0 N ry 0 O �_ � N V) L LU Z J W //_nj V z_ 0 70 Lo CY)CCM CY) U CIO Z3 G (n Lo J CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2) ADJACENT TO BACK FED BREAKER 705.12(B)(1)(3)(b) PLACE NEXT TO INVERTER AC DISCONNECTS 690.56(C) (3) CONDUITS AND RACEWAYS EVERY 10' 690.31(G) (3) PLACE ON MSP DC DISCONNECTS AND J-BOXES SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF'' POSITION TO SOLAR ELECTRIC PV PANELS SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY PLACE ON GENERATION COMBINER PANEL PLACE ON SYSTEM DISCONNECTS PLACE ON BU/CRITICAL LOADS PANEL PLACE ON GENERATION PANEL CEC 690.56(C)(1)(A) Label for PV Systems that shut down the array and the conductors leaving the array. The title "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN' shall utilize capitalized characters with a minimum height of 9.5 mm (3/8in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3/16 in.) in black on white background. ESS DISCONNECT AT MSP SYSTEM DISCONNECT This item has been digitally signed and sealed on Apr 05, 2024 PLACE ON GATEWAY AND MSP (2) PLACE ON DC DISCONNECT PLACE ON SERVICE ENTRANCE CFC.1207.4.8 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE04/16/2024 B, Michael Rango M6Cha bjZa4ujo" 760.322.4433 Lic. C46 - No. 940550 co N UU U (D N U i o T T 0)CY) M p 0 Q CM o U rn LU LU N N M LL Zo a a N L ZCL M 121- _ O �_ O O J ==l V a M (D C: J 00 Q O U) � CV a V (CC0 J (D Z Q � 7FD o �_ U LO co rn Q U cl 0 � G Lj J Drawn by y7 Checked by: MJR Date: 4/1 /2024 Scale: NTS Job Number: 15001 Sheet Number PV-3.0 Sheet 01 • 20.4% efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. • High performance Delivers excellent performance in real world conditions, such as high temperatures, clouds and low light.' • Proven value Designed for residential rooftops, E-Series panels deliver the features, value and performance for any home. Maxeon° Solar Cells: Fundamentally better. Engineered fcr performance deslg � .: iurability Engineered for peace of mind Designed to deliver consistent, trouble -free energy over a very long lifetime."." Designed for durability The SunPower" Maxeon Solar Cell is the only cell built on a solid copper foundation. Virtually impervious to the corrosion and cracking that degrade Conventional Panels." 5 # 1 Ranked in Fraunhofer durability test. 100% power maintained in Atlas 25' comprehensive PVDI Durability test.''' HIGH PERFORMANCE & EXCELLENT DURABILITY ■ IN� e ■ SERIES ■ E20 - 327 PANEL HIGH EFFICIENCY Generate more energy per square foot E-Series residential panels convert more sunlight to electricity producing 30cc more power per panel,' and 60% more energy per square foot over 25 years. HIGH ENERGY PRODUCTION Produce more energy per rated watt High year one performance delivers 79% more energy per rated wait. 3This advantage increases over time, producing 20% more energy over the first 25 years to meet your needs.° Is 120% 1 10% 100% 90% 80% 70% 60% 50% 0 35% more, year 25 5 10 15 20 25 Years t09 Maintains High R - Power at High Temps No LighOnduced Degradation High Average warts 4`''° Better Low -Light and Spectral Response High -Perform once Anti -Reflective Cilc� U' S C� N �a,PHOTON S' -"Vie FtE10�' sunpowercorp.com SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY 100% 95% 85`Yu Traditional 80% Warranty 75% 0 ip 15 20 Years More guaranteed power: 95% for first 5 years,-0.4%/yr. to year 25.8 ELECTRICAL DATA E20-327 E19-320 Nominal Power" (Pnom) 327 W 320 W Power Tolerance +5/-0°0 +5/-0% Avg. Panel Efficiency" 20.4% 19.9% Rated Voltage (Vmpp) 54.7 V 54.7 V Rated Current (Impp) 5.98 A 5.86 A Open -Circuit Voltage (Voc) 64.9 V 64.8 V Short -Circuit Current (Isc) 6.46 A 6.24 A Maximum System Voltage 600 V UL & 1000 V IEC Maximum Series Fuse 20 A Power Temp Coef. (Pmpp) -0.38% / aC Voltage Temp Coef. (Voc) -176.6 mV / aC Current Temp Coef. (Isc) 3.5 mA / aC REFERENCES: 1 All comparisons are SPR-E20-327 vs. a representative conventional panel: 240W, approx. 1.6 ml, 151/o efficiency. 2 PVEvolution Labs "SunPower Shading Study," Feb 2013. 3 Typically 7-9% more energy per watt, BEW/DNV Engineering "SunPower Yield Report," Jan 2013. 4 SunPower 0.25%/yr degradation vs. 1.09/6/yr cony. panel. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013; Jordan, Dirk "SunPower Test Report," NREL, Oct 2012. 5 "SunPower Module 40-Year Useful Life" SunPower white paper, Feb 2013. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 6 Out of all 2600 panels listed in Photon International, Feb 2012. 7 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels, 102 companies), Photon International, March 2013, 8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb 2013. 9 Some exclusions apply. See warranty for details. 10 5 of top 8 panel manufacturers were tested by Fraunhofer ISE, "PV Module Durability Initiative Public Report," Feb 2013. 11 Compared with the non -stress -tested control panel. Atlas 25+ Durability test report, Feb 2013, 12 Standard Test Conditions (1000 W/ml irradionce, AM 1.5, 25' Q. 13 Based on average of measured power values during production. 0 10 15 J Years Combined Power and Product Defect 25 year coverage that includes panel replacement costs.' OPERATING CONDITION AND MECHANICAL DATA Temperature - 40F to +185°F (- 40'C to +85°C) Max load Wind' 50 psf, 2400 Pa, 245 kg/m2 front & back Snow: 112 psf, 5400 Pa, 550kg/m2 front Impact 1 inch (25 mm) diameter hail at 52 mph (23 m/s) resistance Appearance Class A Solar Cells 96 Monocrystalline Maxeon Gen II Cells Tempered Glass High Transmission Tempered Anti -Reflective Junction Box IP-65 Rated Connectors MC4 Compatible Frame Class 1 black anodized, highest AAMA Rating Weight 41 Ibs (18.6 kg) TESTS AND CERTIFICATIONS Standard tests UL 1703, IEC 61215, IEC 61730 Quality tests ISO 9001:2008, ISO 14001:2004 EHS Compliance RoHS, OHSAS 18001 :2007, lead-free, PV Cycle Ammonia test IEC 62716 Salt Spray test IEC 61701 (passed maximum severity) PID test Potential -Induced Degradation free: 1000V 10 Available listings CEC, JET, KEMCO, MCS, FSEC, CSA, UL, TUV 46mm _ [1.81in] 1559mm [61.4in] 1046mm [4 1.2in] See h"p://www.sunaowercora.com/facts for more reference information. For further details, see supplementary specs: www.sunpowercorp.com/dolasheets. Read safety and installation instructions before using this product. 9: April 2013 SunPower Corporotion. All rights reserved. SUNPOWER, the SUNPOWER logo, MAXEON, MORE ENERGY, FOR LIFE., and SIGNATURE are frademotks or registered trodemoiks of SunPower corporarwn. Specificatwns included In this darasheet are subied to change without notice. sunpowereorp.eom Document p 504860 Rev B ; LTR EN Powerwall 3 Powerwall 3 Technical Specifications Power Everything Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 150 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production, fast and efficient installations, easy system expansion, and simple connection to any electrical service. System Technical Model Number 1707000-xx-y Specifications Nominal Grid Voltage (Input 8 Output) 120/240 VAC Grid Type Split phase Frequency 60 Hz Overcurrent Protection Device Configurable up to 60 A Solar to Battery to Grid Round Trip Efficiency 89%1.2 Solar to Grid Efficiency 97% 5 Supported Islanding Devices Backup Gateway 2. Backup Switch Connectivity Wi-Fi (2.4 and 5 GHz), Dual -port switched Ethernet, Cellular (LTE/4G 4) Hardware Interface Dry contact relay, Rapid Shutdown (RSD) certified switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- O.S%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI), PV Rapid Shutdown (RSD) using Tesla Mid -Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years Solar Technical Maximum Solar STC Input 20 kW Specifications Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range ISO — 480 V DC MPPTs 6 Maximum Current per MPPT (I,,) 13 As Maximum Short Circuit Current per MPPT (Iw) 15 A 5 Battery Technical Nominal Battery Energy 13.5 kWh AC' Specifications Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0-1(Grid Code configurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability (1 s) 150 A LRA Power Scaiability Up to 4 Powerwall 3 units supported 'Typical solar shifting use case. 2 Values provided for 25°C (770F), at beginning of life. 3.3 kW charge/discharge power. 1 Tested using CEC weighted efficiency methodology. 4Cellular connectivity subject to network service coverage and signal strength. ' Where the DC input current exceeds the MPPT rating, a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A Imp / 30 A ISM. 2023 1 2023 Powerwall 3 Datasheet Powerwall 3 Technical Specifications Solar Shutdown Device Technical Specifications Environmental Operating Temperature Specifications Operating Humidity (RH) Storage Temperature Maximum Elevation Environment Enclosure Rating Ingress Rating Pollution Rating Operating Noise @ 1 m -206C to 50°C (-4°F to 122°F) 6 Up to 100%, condensing -20-C to 30-C (-4-F to 860F). up to 95% RH, non - condensing, State of Energy (SOE): 25% Initial 3000 m (9643 ft) Indoor and outdoor rated NEMA 3R IPX7 (Battery & Power Electronics) IPX5 (Wiring Compartment) PD3 <50 db(A) typical <62 db(A) maximum 6 Performance may be de -rated at operating temperatures above 400C (1040F). Compliance Certifications UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, Information UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547-2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A Mechanical Specifications 2023 Dimensions Weight Mounting Options Powerwall 3 Datasheet 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) 130 kg (287 lb) Floor or wall mount P0 0 o O 609 mm � 193 Imml 3 The Solar Shutdown Device is a Mid -Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Electrical Model Mcl-1 MCI-2 Specifications Nominal Input DC Current Rating (I.) 12 A 13 A Maximum Input Short Circuit Current (IK) 19 A 17 A RSD Module Performance Environmental Specifications Mechanical Specifications Compliance Information Maximum System Voltage (PVHCS) 600 V DC 1000 V DC' ' Maximum System Voltage Is limited by Powerwall to 500 V DC. Maximum Number of Devices per String 5 5 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years Operating Temperature Storage Temperature Enclosure Rating Electrical Connections Housing Dimensions Weight Mounting Options Certifications RSD Initiation Method UL 3741 PV Hazard Control (and PVRSA) Compatibility -400C to 50-C -45'C to 70°C (-40-F to 1220F) (-490F to 158°F) -300C to 700C -300C to 700C (-220F to 158°F) (-22°F to 158°F) NEMA 4X / IP65 NEMA 4X / IP65 MC4 Connector MC4 Connector Plastic Plastic 12SxISO x22mm 173x45x22mm (Sx6xIIn) (6.8 x 1.8 x I In) 350 9 (0.77 lb) 120 g (0.26 lb) ZEP Home Run Clip Wine Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw UL 1741 PURSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) External System Shutdown Switch or Powerwall 3 Enable Switch The following categories of solar module meet the UL 3741 PVHCS listing when Installed with Powerwall 3 and Solar Shutdown Devices. Tesla Solar Roof Tesla or Hanwha (O.Peak Duo BLK or BLK-G6+) Modules certified for use with ZEP racking Other module and racking combinations 2023 Powerwall 3 Datasheet 4 Backup Gateway 2 Backup Switch Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self -consumption, time -based control, and backup operation. In this system configuration, Powerwall 3 acts as the Site Controller, with the Backup Gateway 2 Site Controller disabled. Performance Model Number 1232100-xx-y Specifications AC Voltage (Nominal) 120/240 V Feed -in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply 10 kA A Short Circuit Current Overcurrent 100 - 200 A, Service Protection Device entrance rated" Overvoltage Category Category IV AC Meter Revenue accurate (+/- 0.2%) " When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. Environmental Operating Temperature Specifications Operating Humidity (RH) Compliance Information Mechanical Specifications Maximum Elevation Environment Enclosure Type Certifications Emmissions Dimensions 660 x 411 x 149 mm (26x16x6in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi -flush mount Primary Connectivity Ethernet, Wi-Fi Secondary Cellular (3G, LTE/4G) e Connectivity User Interface Tesla App Operating Modes Support for solar self - consumption, time -based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC - coupled Powerwalls Optional Internal 200 A 6-space / 12 Panelboard circuit Eaton BR circuit breakers Warranty 10 years • The customer is expected to provide Internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. -200C to 500C (-40F to 1220F) Up to 100%. condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R UL 67. UL 869A, UL 916, UL 1741 PCs, CSA 22.2 0.19, CSA 22.2 205 FCC Part 15, ICES 003 ddu mm The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. Performance Specifications Environmental Specifications Compliance Information Mechanical Specifications Model Number 1624171-xx-y Continuous Load Rating 200 A.120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 10 Communication Expected Service Life Warranty CAN 21 years 10 years 10 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Operating Temperature -40-C to SOOC (-40-F to 1220F) Storage Temperature -400C to SS-C (-400F to 18S-F) Enclosure Rating NEMA 3111 Pollution Rating PD3 Safety Standards USA: UL 414, UL 273S, UL 916, CA Prop 6S Emmissions FCC, ICES Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) Weight 2.8 lb Meter and Socket Compatibility Floor or wall mount External Service Interface Conduit Compatibility Contactor manual override" Reset button 1/2-inch NPT 11 Manually overrides the contactor position during a service event 21 2023 Powerwall 3 Datasheet S 1 2023 Powerwall 3 Datasheet 6 Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup �kup V. (D Meter Grid Meter socket panel Load center I Backuploads Powerwall 3 with Backup Gateway 2 Partial Home Backup It�pwerwall 3 Utility Meter O - Main _ Breaker Grid Meter load center I eS5 Non -essential loads i Solar Load center I Backup loads i Solar 2023 Powerwall 3 Datasheet 7 I tI rt k Intertek 3933 URoute 11 Cortland, NY 13045 Total Quality Assured Telephone: 607-753-7311 www.intertek.com Verification of Conformity On the basis of the evaluations undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address Tesla Inc. 3500 Deer Creek Road. Palo Alto, CA 94304 Product(s) Tested AC Powerwall - Grid Support Utility Interactive Inverter Gateway Ratings and principal characteristics See Amendment 1 AC Powerwall Model(s) 1092170-xx-y, 2012170-xx-y Gateway Model(s) 1232100 - followed by two numbers; followed by one letter Brand name MD5 checksum Tesla b624638a90cf Relevant Standard(s) Specification(s) Inverters, Converters. Controllers And Interconnection System Equipment For Use With Distributed Energy Resources [UL 1741:2010 Ed.2(Supplement SA)+R:15Feb2018] Power Control Systems (PCS) Certification Requirement Decision 3 8 2019 Verification Issuing Office Name & Intertek, 3933 US Route 11, Cortland, NY 13045, USA Address Gateway Date of Test(s) 11/4/2019-12/4/2019 and 4/23/2020 to 5/13/2020 Verificatiom Report Number(s) 104267560CRT-001, 103879962CRT-003 NOTE: This verification is part of the full test report(s) and should be read in conjunction with it. IThis Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility Ond liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the somple tested/inspected. This (Verification by itself does not imply that the material, product, or service is or has ever been under on Intertek certification progrom.1 Signature Name: Dipesh Patel Position: Sr. Project Engineer Date: 20 May 2020 Amendment 1: Backup Gateway North America 2.0 Nameplate www.intertek.com GFT-OP-11e (7-March-2017) GFT-0P-11e (7-March-2017) Haatnonal uaiewav z.0 nH vuz, o raunas Maximum PCS controlled current 200A Average Open loop response 0.96 seconds (60ms added for delay between 1" and 9'h ACPW Maximum open loop response 1.76 seconds (60ms added for delay between 15 and 9'h ACPW AC Powerwall Ratings Protective Class Class I Enclosure Type Type 3R Ingress Protection Battery & Power IP 67 / IP 56 Electronics/Mirin Operating Temperature Range -20QC to +50 QC Derated Temperature Range +43 QC to +50 QC Inverter Topology Isolated Battery Energy 13.5 kWh Battery Type Li.lon Weight 125 K AC Input / Output Nominal Voltage A.C. V 100/120/200/208/220/230/240 Voltage Range & Max 90-110 V AC: 25A Continuous Current 114-126 V AC: 24A 180-220 V AC: 25A 198-220 V AC: 24A 198-242 V AC: 25A 207-253 V AC: 25A 228-252 V AC: 24A Frequency Range/Nominal Hz 50-60.50/60 Max Continuous Power (kVA) 100 V AC: 2.5 WA 120 V AC: 2.9 kVA (USA) 200 V AC: 5 kVA 208 V AC: 5 kVA(USA) 220 V AC: 5.5 kVA 230 V AC: 5.8 WA 240 V AC: 5.8 kVA USA -0.85 to +0.85 Power Factor Range Max Output Fault Current 32 A AC 200V/208V/240V; 2W +N +PE; Phase 20; All Other Voltages; 1 W +N +PE; 10 Max Supply Fault Current 10 kA AC Lntertek Total Quality. Assured Revision History Intertek 3933 US Route 11 Cortland, NY 13045 Telephone: 607-753-7311 www.interiek.com Date Engineer / Reviewer I Description of Change 6/3/2020 Dipesh Patel Changed Model number from "Backup Gateway ��- North America 2.0" to "1232100 - followed by two numbers; followed by one letter" www.intertek.com G F I -OP-1 le (7-March-2017) www.intertek.com GFT-OP-1 le (7-March-2017) MEAT ALARM w-HD6135FB 1350 FIXED & RATE OF RISE Microprocessor controlled -Features Fixed Rate and Rate of Rise temperature sensing - allows unit to alarm prior to reaching the fixed temperature setting of 1350 F. IR REMOTE CONTROL Can test or silence thealarm with most household remote controls.. LATCHING ALARM INDICATOR Remembers which unit initiated an alarm. SINGLE BUTTON TEST/SILENCE Silences and tests alarm with a single button. TWO LOCKING FEATURES Pins are provided to lock battery drawer and/or alarm to base. Perfect for apartment, dormitory or hotel applications. 10A. �Z 1 `1 R R ,\O IONIZATION Listed to UL 539 ®' N 120VAC, 60Hz Wire -in with 9V Battery Backup Description: The BRK Brands, Inc. Model Number HD6135FB is a wire -in, 120V AC 60Hz single and/or multiple station heat alarm designed to supplement smoke alarms in residential and institutional applications including sleeping rooms of hospitals, hotels, motels, dormitories and other multi -family dwellings as defined in standard NFPA 101. Models HD6135FB complies with UL539, CSFM, NFPA 72, HUD, FHA and other agencies that model their codes after the above agencies. They meet building codes where AC and AC/DC with Silence heat alarms are required. The alarms are interconnectable with up to 18 devices, of which 12 can be smoke alarms. This heat alarm is not a smoke alarm nor has it been designated a life safety device. BRK Electronics HD6135FB is designed to give reliable early warning of heat from fire. It is recommended for garages, crawl spaces, bathrooms, kitchens, laundry rooms or other applications not suitable for smoke alarm installations. It features exclusive IR remote control test/silence that can be activated by most household remote controls. The unit contains a thermistor that senses heat and will alarm when either the temperature reaches 1350F or when a rate of rise of 150F/minute is sensed by the microprocessor. This feature enables a more rapid response to a potential fire. The unit has an 85dB horn, a 9V battery backup power supply, an easy access side -load battery drawer. This alarm features Alarm Latch: Easily identifies initiating alarm even after alarm condition has subsided; Low Battery Silence: Temporarily silence the low battery chirp for up to eight hours; Alarm Silence: Silence alarm for several minutes. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a Quick -Connect wiring harness. Installation is quick. easy and cost effective. 0 I 1� F ors El % pA \ 'AT-HD6135FB @ CA-01 * 2 0- ARCHITECTURAL AND ENGINEERING SPEC The heat alarm shall be a BRK Model HD6135FB and shall provide at a minimum the following features and functions: 1. A thermistor and microprocessor capable of sensing and alarming at a 135T fixed temperature level and a 15'F!min. rate of nse tempertaure change. 2. The unit shall be capable of self restoring. 3. Powered by 120V AC. 60Hz and have a monitored 9V battery backup and a solid state piezo horn rated at 85d6 at 10 ft. 4. A visual green LED power -on indicator to confirm unit is receiving power or is in alarm. 5. A full function test button should check all alarm functions by simulating a smoke condition, causing the unit to alarm. 6. Silence feature - Temporanly silence unwanted nuisance alarms. 7. An infrared remote (IR) feature to test and/or silence the alarm with most household remote controls. 8. Two Locking features - tamper resistant locking pins that lock battery drawer and/or alarm to mounting bracket. 9. The unit shall be capable of operating between -10°F (-23°C) and 1003F (38 C) and relative humidity between 10% and 90%. 10. The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment. 11. The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms, 12 of which can be smoke alarms. 12. The unit shall at a minimum meet the requirements of UL539. CSFM, NFPA 72, NFPA 101. ICC INSTALLATION OF ALARM Installation of this heat alarm must conform to all local electrical codes and Article 760 of the Nabonal Electrical Code (NFPA 70) and NFPA 72. Interconnected units must meet the following _-- requirements: Total length of wire interconnecting units should be less than 1000 feet, be #18 gauge or larger and be rated at least 300V. ft is recommended that all units be on the same fuse or circuit breaker. If local codes do not permit, be sure the neutral wire is common to both phases. THE PARTS OF THIS HEAT ALARM 1. Mo WOV bracket 2. Moor rtkng Skills 3. Locking Pins 4. Hot (Black) AC Wire 5. Nuutral (Whae) AC Wire 8. Interconnect (Orange) Wire 7. Battery Drawer Latch 8. Battery Drawer - Install 9V battery here IJIL9 Ouxyk-Connect Plug - A. Unswached 1 source B. To additional uruts. Maximum - 18 total (Maximum 12 Smoke Alamts) 1, Smoke Alarm 5. Junction Box 2. Ceiling or War & Neutral Wire (White) 3. Power Connector 7. Interconnect Wire (Orange) 4. Wire Nut 8, Hot W,re (Black) TECHNICAL SPECS Alarm Dimensions: 5.4" dia x 2.2'H Weight: 7.3 oz Operating Voltage: 120V AC 60Hz w/ 9V battery backup Operating Current: .05 amps (standby/alarm) Temperature Range: -10°F (-23°C) to 100°F (38°C) Humidity Range: 10% to 90% relative humidity (RH) Audio Alarm: 85dB at 10 feet Test/Silence: Electronically simulates alarm condition, causing the unit to alarm Press and hold test/silence button Alarm Reset. Automatic when temperature cools below 1301 Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and Heat Alarms Maximum of 12 smoke alarms See user's manual for details. Heat Sensor Thermistor Indicator Lights/Sounds: AC Power: Constant Green LED DC Power. Intermittent Green LED Local Alarm: Red LED flashes rapidly, audio alarm Remote Alarm: Red LED out. Latching Alarm: Red LED flashes after local alarm stops Listing: Listed to UL539 Standard SHIPPING SPECS: Individual Carton Dimensions 5.50"L x 2.50"W x 5.63"H Weight 0.50 lbs. Cube 0.045 M UPC 0 29054 50810 2 Master Carton Dimensions 16.811 x 10.31 "W x 6.25"H Master Pack 12 Weight 6.3 lbs. Cube: 0.63 f13 12of5: 100 29054 50810 9 Pallet Information Cases per Layer 10 Number of Layers: 7 Cases per Pallet: 70 Units per Pallet: 840 Cube: 54.7 ft3 Weight: 550 lbs. brkelectronics.com ®2009 BRK Brands, Inc a Jarden corporation CompanylNYSE JAH) 3901 Liberty Street Road Aurora. Ill 60504-8122 All rights reserved First Alert is a registered trademark of the First Alert Trull BRK is a registered trademark of BRK Brands, Inc. CM2944