_2022 CF1R-PLB-01-E Hydronic Heating System Worksheet_v1HYDRONIC HEATING SYSTEM WORKSHEET a CALIFORNIA ENERGY COMMISSION CEC- UlR-PLB-01-E CERTIFICATE OF COMPLIANCE Note: This table completed by HERS Registry. Field Name Data Entry Field Name Data Entry Project Name: RECREATION MANAGMENT SOL Enforcement Agency: Dwelling Address: 53697 VIA DONA Permit Number: City and Zip Code: LA QUINTA 92253 Permit Application Date: 1-9-25 A. Pipe Heat Loss Worksheet 01 02 03 04 Pipe Diameter (inches) Pipe Heat Loss Factor (kBtu/year/ft) Pipe Length (ft) Pipe Heat Loss (kBtu/year) 05 Sum of All Pipe Heat Losses (kBtu/year) 06 Average Hourly Pipe Heat Loss (Btu/hr) B. Hydronic System Calculations for Large Storage Gas Field Field Name Data Entry Recovery Efficiency/AFUE of the Water 01 Heater or Boiler (unitless) 02 Average Hourly Pipe Heat Loss (Btu/hr) 03 Rated Input of Water Heater or Boiler 199 000 (Btu/hr) 04 Standby Loss —Percentage (if known) Standby Loss —Power (Btu/hr) 05 (from appliance database, if known) 06 Pump Watts (Watts) (if applicable) 07 Pump Energy (Btu/hr) 199,000 08 Effective AFUE CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022 HYDRONIC HEATING SYSTEM WORKSHEET CALIFORNIA ENERGY COMMISSION CEC- CF1R-PLB-01-E Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Robert Pavia Robert Pavia Company: Signature Date: ROTO ROOTER PLUMBERS 1-9-25 Address: CEA/ HERS Certification Identification (if applicable): 16819 LITTLE MORONGO RD City/State/Zip: Phone: DESERT HOT SPRINGS CA 92240 442-400-4150 Responsible Person's Declaration Statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 understand that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. 6. 1 understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Robert Pavia Robert Pavia Company: Date Signed: Roto Rooter Plumbers 1-9-25 Address: License: 16819 little morongo rd 966412 City/State/Zip: Phone: Desert Hot Springs CA 92240 442-400-4150 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300 CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022 CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS CF1R-PL13-01-E Hydronic Heating System Worksheet (Page 1 of 2) CF1R-PLB-01-E User Instructions A. Pipe Heat Loss Worksheet 1. Pipe Diameter (inches): Enter all the different pipe diameters of the system. User selects from list: 0.75, 1.0, 1.5 2. Pipe Heat Loss Factor (kBtu/year/ft): Using the table below, determine the pipe heat loss factor for the corresponding pipe diameter. 3. Pipe Length (ft): Enter the pipe length. 4. Pipe Heat Loss (kBtu/year): Multiply line B02 by B03, this is the pipe heat loss. 5. Sum of All Pipe Heat Losses (kBtu/year): Enter the sum of all pipe heat loss. 6. Average Hourly Pipe Heat Loss (Btu/hr): Divide line B05 by 8760 times 1000. Pipe Heat Loss Factor Lookup Table Pipe Nominal Diameter Pipe Heat loss factor 0.75 66.6 1.0 78.8 1.5 100.3 B. Hydronic System Calculations for Boiler or Large Storage Gas 1. Recovery Efficiency/AFUE of the Water Heater or Boiler: Enter the Recovery Efficiency/AFUE from manufacturer's literature or the appliance database. 2. Average Hourly Pipe Heat Loss (Btu/hr): Enter average hourly pipe heat loss sum A06. 3. Rated Input of Water Heater or Boiler (Btu/hr)Enter the rated input from manufacturer's literature or the appliance database. 4. Standby Loss — Percentage: Enter the standby loss percent from manufacturer's literature or the appliance database. For example, enter 0.02 if the standby loss is 2%. Can be skipped if unknown 5. Standby Loss — Power: Standby loss energy (from appliance database) is used if standby loss percent is not known. Enter the standby loss energy from manufacturer's literature or the appliance database. 6. Pump Watts (Watts): Enter the pump watts 7. Pump Energy (Btu/hr): Pump energy is line A06 times 3.414. If unknown then default value is 85. 8. Effective AFUE: Effective AFUE is [line A01— (line A02+ line A05 + (line A07 / line A03)]. CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022 CERTIFICATE OF COMPLIANCE — USER INSTRUCTIONS CF1R-PLB-01-E Hydronic Heating System Worksheet (Page 2 of 2) Documentation Declaration Statements 1. The person who prepared the CHR will sign and complete the fields for their name, company (if applicable), address, phone number, certification information (if applicable), date and signature (may be electronic). 2. The person who is assuming responsibility for the project being built to comply with Title 24, Part 6, will complete the fields for their name, company (if applicable), address, phone number, license number (if applicable), date and signature (may be electronic). CA Building Energy Efficiency Standards - 2022 Residential Compliance January 2022