Loading...
BPOL2024-0316BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 12/18/2024 ISSUED DATE: 01/24/2025 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Pool 51911 MARQUIS LANE BPOL2024-0316 777480003 Lot 3 MB 411/31 TR 30138 $34,475.00 RL, 3 Owner:CHRIS CICOGNA Applicant:Malachi Bermudez 77980 Wildcat Dr Ste 2, Palm Desert, CA 92211 Contractor:Malachi Bermudez / 1010403 77980 Wildcat Dr Ste 2, Palm Desert, CA 92211 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 10/29/25 8:46 am Page 1 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2024-0316 51911 MARQUIS LANE BUILDING PERMIT FUSCO / NEW POOL AND SPA IN LOCATION OF PREVIOUS POOL THAT WAS REMOVED. POOL EQUIPMENT TO BE RELOCATED TO APPROVED LOCATION AS SHOWN ON THIS SITE PLAN [POOL ENGINEERING INC.] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS A PART OF. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE. Use of Permit Construction Details POOL ENGINEERING INC.Engineer of Record 0Quantity of Detached Spa(s)/Water Feature(s) 4BBQ Electrical (EA) 1Number of Gas Outlet(s) 0Mechanical Equipment Relocation (QTY) 0Garden Wall Linear Foootage 0Combination Retaining Wall Linear Footage 0Total Wall Length (Linear Footage) RLZoning LDRGeneral Plan Within La Quinta LimitsCity Limits TR 30138Subdivision Name 3Lot Number 1165.58Lot Size 99948Centerlines Lot 3 MB 411/31 TR 30138Legal Description Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00012204 $31.81 Receptacle, switch, lighting, or other outlets PC $31.81 $31.81 Gas Piping System Outlets PC $31.81 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $2.00 Building Standards Administration $2.00 $129.79 Swimming Pool / Spa PC $129.79 $15.91 Gas Piping System Outlets $15.91 $238.58 Swimming Pool / Spa $238.58 $23.99 Technology Enhancement Fee $23.99 $31.81 Receptacle, switch, lighting, or other outlets $31.81 $517.70 $517.70 Total for Invoice INV-00012204 Grand Total for Permit $517.70 $517.70 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 12/20/2024 12:16 Submittal Document Verification v.1 Generic Action 12/20/2024 12:16 Plan Check v.1 12/20/2024 0:00 01/23/2025 16:35 Building Review (1 Day) v.1 Receive Submittal 12/20/2024 0:00 12/26/2024 13:46 Building Review (1 Day) v.2 Receive Submittal 01/17/2025 0:00 01/23/2025 16:35 Permit Issuance v.1 01/23/2025 16:36 01/24/2025 9:55 Verify Contractor info & Conditions have been met v.1 Generic Action 01/23/2025 16:38 Verify & Invoice Fees v.1 Generic Action 01/24/2025 8:40 Printed: 10/29/25 8:47 am Page 2 of 3 Permit Type: Permit Number: Property Address: Pool BPOL2024-0316 51911 MARQUIS LANE BUILDING PERMIT Verify Fee Payment & Issue Permit v.1 Generic Action 01/24/2025 9:55 Print, Attach, and Email Building Permit v.1 Create Report 01/24/2025 9:55 01/24/2025 9:55 Pool Permit Inspection v.1 02/14/2025 0:00 Pre-Gunite v.1 Inspection 02/14/2025 0:00 02/18/2025 8:38 Underground Plumbing v.1 Inspection 03/03/2025 0:00 03/04/2025 15:35 Underground Plumbing v.2 Inspection 03/18/2025 0:00 03/19/2025 16:00 Underground Electrical v.1 Inspection 03/03/2025 0:00 03/04/2025 8:49 Underground Gas v.1 Inspection 03/03/2025 0:00 03/04/2025 8:48 Underground Gas v.2 Inspection 03/18/2025 0:00 03/19/2025 9:29 Deck Bond v.1 Inspection 03/18/2025 0:00 03/19/2025 15:56 Pre-Plaster v.1 Inspection 04/21/2025 0:00 04/22/2025 8:56 Footing v.1 Inspection Bond Beam v.1 Inspection Inspections - Final v.1 04/29/2025 0:00 05/01/2025 10:39 Final Pool v.1 Inspection 04/29/2025 0:00 04/30/2025 11:10 Final Pool v.2 Inspection 04/30/2025 0:00 05/01/2025 10:39 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 10/29/25 8:47 am Page 3 of 3 September 25, 2024 Jesseka Fusco 26501 Rancho Parkway S Ste 104 Lake Forest, CA 92630 ARC MODIFICATION APPROVAL WITH CONDITIONS Reference: 51911 Marquis Lane, La Quinta, CA 92253 Dear Jesseka Fusco, Your Request for an Architectural Modification on your property at 51911 Marquis Lane has been approved with conditions by the Architectural Request Committee of Diamante Community Association. Specifically, you have approval to proceed with the following request: - . Take out pool and rebuild pool Add travertine pavers, walnut color Pebble teck Acqua Blue Pool dimensions 28 1/2 ft long, 15 ft wideYour approval is subject to the following conditions which must be adhered to: Conditions: Upon completion of your project, we kindly ask that you fill out and submit a Notice of Completion along with photos. This will help us keep track of any changes made and ensure that the project is in compliance with our guidelines. Approval of plans shall not constitute a representation, warranty, or guarantee that such plans and specifications comply with engineering design practices or zoning and building ordinances, or other governmental agency regulations or restrictions. The Board/Architectural Review Committee (ARC) shall not be responsible for reviewing, nor shall its approval of any plans or design, be deemed approved from the standpoint of structural safety or conformance with building or other codes. By approving such plans and specifications, neither the Board, the ARC, the Members thereof, the Association, any Member thereof, or the Declarant (if still in place) assumes any liability or responsibility therefore or for any defect in the construction or improvement from such plans or specifications. Diamante Community Association PROFESSIONALLY MANAGED BY (760) 776-5100 | managementtrust.com Please note that the ARC reserves the right to make a final inspection to ensure that your project is compliant with the Architectural Design Standards applicable to your neighborhood. Thank you for adhering to the architectural guidelines of the community. We appreciate your patience while this information was being reviewed. Should you have any questions, please feel free to contact our office at (760) 776-5100 or logging into your owner portal at my.managementtrust.com, navigating to the My Items page, and commenting on this item XN XN23321751. We thank you for your patience in this process. Sincerely, Diamante Community Association This Community is Professionally Managed By: The Management Trust California Desert PO Box 13710 Palm Desert, CA 92255 Diamante Community Association 39 Diamante Community Association Notice of Completion Form Return to: The Management Trust, 39-755 Berkey Drive, Suite A, Palm Desert, CA 92211 Palmdesertforms@managementtrust.com Name: Address: Phone: Email: Installed per my submitted and approved application Installed per the pre-approved guidelines for yard installations Summary of Completed Improvements ______________________________ Attachments (check box to indicate they have been enclosed): □ Copies of photographs of all improvements included. Please note that Notice of Completion form is not complete if photographs of improvements are not enclosed. Signature: Date: By signing this form, the homeowner is stating that improvements have been completed in accordance to the scope and specification of the approved Architectural Application and in accordance with the Community’s Architectural Guidelines. 3'-0"WD 6"WD B E N C H 5'-0"WD +18" +18" +18" 6'-3" 5' 24'-11" 5' 64'-11" 13 2 ' - 3 " 64'-11" 13 2 ' - 3 " FU S C O R E S I D E N C E 77 - 9 8 0 W I L D C A T D R I V E , S U I T E 2 PA L M D E S E R T , C A CA - C - 5 3 # 1 0 1 0 4 0 3 76 0 . 3 4 5 . 9 7 0 0 51 9 1 1 M A R Q U I S L A N E LA Q U I N T A , C A POOL DETAILS SURFACE AREA: PERIMETER: SIZE:X DEPTHS:TO TYPE: SURFACE AREA: PERIMETER: SIZE: JETS QTY: SPILLWAY TYPE: SPA HEIGHT: N FINISH: EXPANSION JOINTS: SQ. FT: CANTILEVER: STEPS: STEP FACE: DECK DRAINS: SPA DETAILS DECKING ACCESS: ELEVATION: TYPE: CONC. REMOVAL: SOD REMOVAL: 6" R.B.B: EXCAVATION / STEEL 12" R.B.B: 18" R.B.B: 24" R.B.B: 30" R.B.B: TAN SHELF DEPTH: ROCK POCKETS: CENTERS: FILTER: PLUMBING SIZE: POOL PUMP:SIZE: BOOSTER PUMP:SIZE: ADD'L PUMP:SIZE: ADD'L PUMP:SIZE: HEATER:SIZE: CONTROL SYSTEM: SUB PANEL AMP: ADD'L OUTLETS: GAS LINE FT: FOUNTAINS / SPRAYHEADS: SHEER DESCENTS: POOL LIGHTS: PLUMBING: SPILLWAY TYPE: GUNITE SPILLWAY SIZE: DAM WALL WIDTH: MISC: COPING TYPE: MASONRY R.B.B. FACE: REPLACE ACCESS WALL: SPILLWAY TYPE: SPILLWAY SIZE: FIREPIT: BBQ: EQUIP. WALLS: RETAINING WALLS: PLANTER WALL: FENCE TYPE: FENCING HEIGHT: REMOVE & REHANG: GATE TYPE: PEBBLE COLOR: PEBBLE / PLASTER FITTINGS COLOR: STEP TRIM: PLASTER COLOR: UMBRELLA SLEEVE: EST. START: EST. COMPLETION: S C A L E : 1 8 " = 1 '-0 " SPA FACE: SPA LIGHTS: SAND & VISQUEEN: WATERLINE MATERIAL: 400,000 BTU HEATER. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 4'-0" MIN. CLEARANCE TO OPENING WINDOW 33' - 11 2" POLYPROPYLENE GAS PIPE 3 4" PVC ELECTRIC CONDUIT WITH #10 AWG WIRE TO SUBPANEL POOL EQUIPMENT SUBPANEL WITH 36" CLEARANCE AT FRONT GUNITE 312 SQ. FT. 75 LN. FT. 25'-0"12'-6" 3'-0"5'-0" 9'-6"7'-0" 66 SQ. FT. 33 LN. FT. 12 HYDROTHERAPY JETS +18" TILE VENEER SEE NOTES SEE NOTES YES N/A NO NO NO BY HAND RIGHT SIDE YARD NO NO SPA / 28 LN.FT. 6" WATER DEPTH NO PER ENGINEERING 60 AMPS 108 LN. FT. N/A NEW - JANDY NEW - JANDY TILE SLAB 1'-6" LN. FT. 15" WIDE TRAVERTINE TILE PER PLAN TILE TILE VENEER N/A N/A N/A N/A N/A POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED 2022 California Residential Code (CRC), is based on the 2021 International Residential Code 2022 California Electrical Code (CEC), based on the 2020 National Electrical Code (NEC) 2022 California Mechanical Code (CMC), based on the 2021 Uniform Mechanical Code (UMC) 2022 California Plumbing Code (CPC), based on the 2021 Uniform Plumbing Code (UPC) 2022 California Green Code (CGC), written by the California Building Standards Commission (CBSC) 2022 California Energy Code (CEC), written by the California Energy Commission (CEC) SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED *NO OUTDOOR SURROUNDING LIGHTING OR LOW VOLTAGE LIGHTING *NO OVERHEAD UTILITY / SERVICE LINES S E L E C T I O N S STONE TILE CONCRETE GROUT CONTROL SYSTEM USER INTERFACE PEBBLE / PLASTER DECKING N/A SUB-BASE TRAVERTINE: T.B.S. T.B.S. EXISTING - JANDY MINI PEBBLE: T.B.S. MISC: WD = WATER DEPTH SB = SET BACK A B B R E V I A T I O N L E G E N D S = SKIMMER A = AUTOFILL STEP TRIM:NO N/A TO MATCH N/A YES - PER PLAN N/A Pe r m i t N u m b e r : B P O L 2 0 2 4 - 0 3 1 6 D A T E :01.17.25 AT EXCAVATION HP = HIGH POINT STUBS:N/A EXISTING - JANDY 2-1 2" SUCTION & 2" RETURN MISC. WATER BONDING AT THIS LOCATION AS NECESSARY X AS NECESSARY SEE SELECTIONS TILE SLAB N/A N/A N/A PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL EXISTING GAS STUB PLAN APPROVED BY: SALESPERSON:CICOGNA SPA AT +18" WITH 18"X24" TRAVERTINE CAP, TILE SLAB SPILLWAY AND TILE OR STONE VENEER FACE RAISED BOND BEAM AT +18" WITH 18"X24" TRAVERTINE CAP, THREE 24" WIDE SHEER DESCENT WATER FEATURES AND TILE OR STONE VENEER FACE TANNING SHELF AT 6" WATER DEPTH WITH ONE UMBRELLA SLEEVE 18" X 24" TRAVERTINE DECKING 12"X24" TRAVERTINE POOL COPING 98 SQ. FT.18"X24" TRAVERTINE CAPS 49 SQ. FT.12"X24" TRAVERTINE COPING 525 SQ. FT.18"X24" TRAVERTINE DECKING PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL PROPERTY LINE EXISTING ELECTRIC STUB USE EXISTING USE EXISTING USE EXISTING USE EXISTING USE EXISTING N/A PER PLAN JANUARY 2025 WATERLINE: T.B.S. RBB FACE: T.B.S. 1438 SQ. FT.FRONT YARD CONCRETE EXISTING PEDESTRIAN ACCESS GATE BPOL2024-0316 01/23/2025Taylor Tuvell FUSCO / NEW POOL AND SPA IN LOCATION OF PREVIOUS POOL THAT WAS REMOVED. POOL EQUIPMENT TO BE RELOCATED TO APPROVED LOCATION AS SHOWN ON THIS SITE PLAN [POOL ENGINEERING INC.] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE ALONG WITH ANYTHING ELSE THE PLAN SHOULD HAVE CLEARLY NOTED AS A PART OF. APPROVED SITE PLAN AND WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING PREVENTION SAFETY FEATURES AND THE REQUIRED ENCLOSURE SHALL BE IN PLACE AT PRE-PLASTER INSPECTION. 2022 CALIFORNIA BUILDING CODE.