Loading...
BSOL2023-0021 - Revision 1 Solar PlansCO V E R S H E E T C-1 1 58892 MARBELLA, LA QUINTA, CA 92253 4.620 kW (AC) AND 5.600 kW (DC) NEW PHOTOVOLTAIC SYSTEM THE ARCHAMBAULT RESIDENCE 05.26.2023 07/25/2023 BSOL2023-0021 REVISION 1: 5.6kW SOLAR ARRAY – (14) 400W HANWHA Q.PEAK DUO PANELS + ENPHASE IQ8M MICROINVERTERS W/(1) 125A SUBPANEL [295SF] 2019 CALIFORNIA BUILDING CODES. TI T L E S H E E T PV SYSTEM SPECIFICATIONS CODE COMPLIANCE PROJECT JURISDICTION SHEET INDEX SCOPE OF WORK VICINITY MAP PHOTOVOLTAIC INSTALLATION PLAN T-1 2 1 NEW CONSTRUCTION 05.26.2023 Structural Only 07/25/2023 BSOL2023-0021 REVISION 1 PV E Q U I P M E N T P L A N M-1 3 MAIN SERVICE ELEVATION AERIAL VIEWCONNECTION DETAIL N.T.S.ROOF SECTION PLAN N.T.S. 1 PV LAYOUT PLAN OUTSIDE INSIDE GARAGE 05.26.2023 Structural Only 07/25/2023 BSOL2023-0021 REVISION 1 PV S I N G L E L I N E E-1 4 GROUNDING DETAIL PV SYSTEM VALUES SINGLE LINE WIRING DIAGRAM MODULES TO INVERTERS GENERAL NOTES PV SYSTEM BOM MAXIMUM NUMBER OF MODULE IN STRING: OPERATING CURRENT: OPERATING VOLTAGE: MAXIMUM SYSTEM VOLTAGE: MAXIMUM SHORT-CIRCUIT CURRENT: 1 MAIN SERVICE PANEL (N) 400A BUSS, (N) 400A MCB (OUTSIDE) 6 (E) SERVICE PANEL 1 2 3 4 5 6 7 8 9 14 14 1 1 1 0 0 1 5 6 (N)400A MCB BRANCH SYSTEM 21 2 DC AC DC AC 3 DC AC 4 DC AC 5 DC AC 6 DC AC 7 DC AC 1 J-BOX 3 NEW PV ARRAY WITH (14) MICROINVERTERS (02) STRINGS OF (07) MODULES WITH (07) MICROINVERTERS 07 18.9A 240V 240V 23.62A 7 MODULES 4 3 J-BOX M 7 1 2 77 20A/2P 4 1 (N)PV ONLYSUBPANEL (E)UTILITY METER 120/240VAC (OUTSIDE) (N)30A PV 20A/2P (N)125A PV ONLY SUBPANEL (INSIDE GARAGE) 5 (N)30A AC DISCONNECT 240VAC, NEMA-3R (OUTSIDE) (N) AC UTILITY DISCONNECT SWITCH 5 7 05.26.2023 21 2 DC AC DC AC 3 DC AC 4 DC AC 5 DC AC 6 DC AC 7 DC AC 1 07/25/2023 BSOL2023-0021 REVISION 1 MO D U L E D A T A S H E E T D-1 5 1 MODULE DATA SHEET 05.26.2023 IN V E R T E R D A T A S H E E T D-2 6 1 INVERTER DATA SHEET 05.26.2023 AT T A C H M E N T D A T A S H E E T D-3 7 1 ATTACHMENT DATA SHEET 05.26.2023 RA I L D A T A S H E E T D-4 8 1 RAIL DATA SHEET 05.26.2023 WA R N I N G P L A C A R D S CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 1 WARNING PLACARDS 9 L-1 WARNING: WARNING: WARNING: ELECTRIC SHOCK HAZARD WARNING: ELECTRIC SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT JUNCTION BOX & CONDUIT RACEWAYS DC DISCONNECTS WARNING: WARNING: INVERTER/PV LOAD CENTER PRODUCTION METER PHOTOVOLTAIC SYSTEM METER AC DISCONNECTS MAIN SERVICE PANEL WARNING: WARNING: PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT WARNING: WARNING: 05.26.2023 07/25/2023 BSOL2023-0021 REVISION 1