BPOL2022-0337BUILDING PERMIT
DESIGN & DEVELOPMENT
DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
PHONE (760) 777-7125
WWW.LAQUINTACA.GOV
APPLIED DATE: 08/16/2022
ISSUED DATE: 02/28/2023
Permit Type:
Permit Number:
Property Address:
APN:
Legal Description
Property Zoning:
Valuation:
Pool
58892 MARBELLA
BPOL2022-0337
764850031
$50,000.00
Owner:Sunrise Sunrise
81570 Carboneras, La Quinta, CA 92253
Applicant:Corena R Killebrew
P O BOX 1046, RANCHO MIRAGE, CA 92270
Contractor:Corena R Killebrew / 728796
P O BOX 1046, RANCHO MIRAGE, CA 92270
Declaration / Acknowledgement
PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR
CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE
FOLLOWING:
LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2)
1) They are licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professions Code, and the
referenced
License is in full force and effect, or;
2) That they are exempt from the Contractors’ State License Law for the
reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or
she is exempt from licensure by a valid exemption. [Section 7031.5,
Business and Professions Code: Any city or county that requires a permit
to construct, alter, improve, demolish, or repair any structure, prior to its
issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the
Contractors’ State License Law (Chapter (commencing with Section 7000)
of Division 3 of the Business and Professions
Code] Any violation of Section 7031.5 by any applicant for a permit
subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).)
a) As owner of the property, or my employees with wages as their sole
compensation, will do all of or portions of the work, and the structure is
not intended or offered for sale (Section 7044, Business and Professions
Code: The Contractors’ State License Law does not apply to an owner of
property who, through employees’ or personal effort, builds or improves
the property, provided that the improvements are not intended or offered
for sale. If, however, the building or improvement is sold within one year of
completion, the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale.).
b) As owner of the property, will be exclusively contracting with licensed
c) Are exempt from licensure under the Contractors’ State License Law.
As an Owner-Builder, they acknowledge that, except for their personal
residence in which they must have resided in for at least one year prior to
completion of the improvements covered by this permit, they cannot legally
sell a structure built as an owner-builder if it has not been constructed in
its entirety by licensed contractors. It is understood that a copy of the
applicable law, Section 7044 of the Business and Professions Code, is
available upon request when this application was submitted at the
following Web site:
http://www.leginfo.ca.gov/calaw.html.
DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If
applicable)
A construction lender will be used for completion of the improvements
covered by this permit and the name and information of which is on file for
public inspection during the regular business hours of the public entity.
Failure of the applicant to indicate the construction lender on the
application does not relieve that person of the requirement to give the
construction lender preliminary notice from that duty.
WORKERS’ COMPENSATION DECLARATION (1, 2 or 3)
WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION
TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION
3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES.
1) Has and will maintain a certificate of consent to self-insure for workers’
compensation, issued by the Director of Industrial Relations as provided for
by Section 3700 of the Labor Code, for the performance of the work for
which this permit is issued.
2) Has and will maintain workers’ compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which
this permit is issued.
3) Certifies that, in the performance of the work for which this permit is
issued, shall not employ any person in any manner so as to become subject
to the workers’ compensation laws of California, and agree that, if should
become subject to the workers’ compensation provisions of Section 3700 of
the Labor Code, shall forthwith comply with those provisions.
NOTICE TO APPLICANT (1, 2 and 3)
1) Each person upon whose behalf this application was made, each person
at whose request and for whose benefit work is being performed under or
pursuant to any permit issued as a result of this application, the owner, and
the applicant, each agrees to, and shall defend, indemnify and hold harmless
the City of La Quinta, its officers, agents, and employees for any act or
omission related to the work being performed under or following issuance of
this permit.
2) Any permit issued as a result of this application becomes null and void if
work is not commenced within 360 days from date of issuance of such
permit, or if cessation of work for 180 days will subject permit to
cancellation. On or after January 1, 2019, every permit issued shall become
invalid unless the work on the site authorized by such permit is commenced
within 12 months after its issuance, or if the work authorized on the site by
such permit is suspended or abandoned for a period of 12 months after the
time the work is commenced.
3) Certified that they read the application and state that the information
provided is correct. Agree to comply with all city and county ordinances and
state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above-mentioned property for
inspection purposes.
IMPORTANT: An Application for Permit was made to the Building Official,
subject to the conditions and restrictions set forth at the time of application,
which is now hereby an Issued Permit. If any part of the information being
supplied on this permit is inaccurate or untrue, please contact the City of La
Quinta at (760) 777-7125 immediately for correction.
Printed: 11/4/25 5:48 pm Page 1 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2022-0337
58892 MARBELLA
BUILDING PERMIT
ARCHAMBAULT / POOL AND SPA AT REAR YARD *** POOL AND SPA AT REAR YARD WITH ELECTRICAL OUTLET (1) AT COURT YARD
[ENGINEERED DESIGN]. APPROVED SITE PLAN AND ENGINEERING REQUIRED ON SITE FOR INSPECTIONS. THIS PERMIT DOES
NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION.
2019 CALIFORNIA BUILDING CODES.
Use of Permit
Construction Details
Valuation Details
Type Group Sq Ft Value
Financial Information
Fee AmountFee Amount PaidInvoice No.
PERMIT-BPOL2022-033
7
$2.00 BSAS SB1473 FEE $2.00
$208.41 SWIMMING POOL/SPA/WATER FEATURE $208.41
$113.38 SWIMMING POOL/SPA/WATER FEATURE PC $113.38
$5.00 TECHNOLOGY ENHANCEMENT FEE $5.00
$11.00 RECORDS MANAGEMENT FEE $11.00
$339.79 $339.79 Total for Invoice PERMIT-BPOL2022-0337
Grand Total for Permit $339.79 $339.79
Workflow / Inspections
Workflow Step / Action Name Action Type Start Date End Date
Inspections v.1 08/16/2022 0:00
DECK BOND v.1 Inspection
UNDERGROUND ELEC v.2 Inspection
UNDERGROUND GAS v.2 Inspection
UNDERGROUND PLBG v.2 Inspection
PRE-GUNITE v.2 Inspection
UNDERGROUND PLBG v.1 Inspection
UNDERGROUND GAS v.1 Inspection
PRE-GUNITE v.1 Inspection
UNDERGROUND ELEC v.1 Inspection
Pool Permit Inspection v.1 03/27/2024 0:00 03/29/2024 12:59
Pre-Plaster v.1 Inspection 03/27/2024 0:00 03/28/2024 10:03
Pre-Plaster v.2 Inspection 03/28/2024 0:00 03/29/2024 12:59
Inspections - Final v.1 04/04/2024 0:00 04/05/2024 11:46
Final Pool v.1 Inspection 04/04/2024 0:00 04/05/2024 11:46
Printed: 11/4/25 5:48 pm Page 2 of 3
Permit Type:
Permit Number:
Property Address:
Pool
BPOL2022-0337
58892 MARBELLA
BUILDING PERMIT
Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work
shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be
construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections
presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be
valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for
inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of
any material required to allow inspection.
It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for
inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this
code.
Inspections
A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion
thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a
certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances
of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the
jurisdiction shall not be valid.
Certificate of Occupancy
A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building
or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by
the building official.
Service Utilities
Printed: 11/4/25 5:48 pm Page 3 of 3
15'-6"
14'-0"
10
'
-
0
"
18"18"18"
5'
-
0
"
1'
4'
-
0
"
20'-0"
POOL EQUIPMENT: 400,000 BTU HEATER
*ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED
87' - 11
2" POLYPROPYLENE GAS PIPE
ELECTRIC CONDUIT
POOL / SPA LIGHT JUNCTION BOX
POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER
POOL EQUIPMENT 50 AMP SUBPANEL
WITH 36" CLEARANCE AT FRONT AND SIDE
MAIN HOUSE 200 AMP ELECTRICAL PANEL
POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
GAS METER
TRANSFORMER
SPA AIR LINE
SUB BASE CONCRETE POURED ON 15mil VISQUEEN
WITH COMPACTED ROAD BASE AND FIBER MESH,
TILE LABOR AND MATERIAL BY OTHERS
ANGELUS COURTYARD UNTUMBLED STONE PAVERS
SAND SET OVER 4" OF COMPACTED ROAD BASE AND
1" OF BEDDING SAND, POLYMERIC SAND GROUT,
MUD SET PERIMETER
PLAN
202B
BA
T
H
MA
S
T
E
R
KI
T
C
H
E
N
PW
D
R
BA
T
H
3
CA
S
I
T
A
EN
T
R
Y
GA
R
A
G
E
2-
C
A
R
GA
R
A
G
E
GO
L
F
C
A
R
T
LA
U
N
SI
T
T
I
N
G
HA
L
L
BA
T
H
2
BE
D
R
O
O
M
MA
S
T
E
R
BE
D
R
O
O
M
2
GR
E
A
T
R
O
O
M
14
0
'
-
3
"
55'-0"
1
4
2
'
-
1
0
"
74'-11"
PL
PL
PL
PL
MARBELLA
G
5'-0" WD
3'-6" WD
0"
0"
0"
0"
DRIVEWAY BY OTHERS
STOOP BY OTHERS
T
J
A
GAS STUB FOR FUTURE USE,
BARBECUE BY OTHERS
G
A
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
GA
S
42" WD
6"
W
D
21
"
W
D
30
"
W
D
15"x24" PRE CAST CONCRETE COPING AT 0" ELEVATION, 6"x24"
TILE WATERLINE, PEBBLE PLASTER INTERIOR FINISH
PB
PB
PB
SPA AT 0" WITH 12" WIDE TILE DAM WALL TO BE 10 1 2" OF FINISH GUNITE,
(7) HYDRO THERAPY JETS AT ALTERNATE HEIGHTS, 6" TILE WATERLINE,
PEBBLE PLASTER INTERIOR FINISH
OPTIONAL
WROUGHT IRON FENCE AT +30" (NO GATE)
ELECTRIC CONDUIT
J-BOX AND THREE WAY SWITCH BY OTHERS, BUBBLE SPRINGS TO INSTALL
CONDUIT FROM J-BOX ON HOUSE TO LAMP LOCATION WITH 2'x2' FOOTING,
(1) WEATHER PROOF ELECTRICAL GFCI OUTLET FOR FUTURE USE
A
S
5'
-
5
"
S
B
.
6'
-
8
"
S
B
.
9'-8" SB.
17
'
-
0
"
S
B
.
27'-1" SB.
25'-8" SB.
5'-
3
"
S
B
.
5
'
-
3
"
S
B
.
2'-1" SB.
3'-1" SB.
HS-1.0
DRAWN BY:
POOL CONSTRUCTION
P.O. BOX 1046, RANCHO MIRAGE, CA 92270
EMAIL: OFFICE@BUBBLESPRINGS.com
LIC# C53-728796
SHEET NO. 1 OF 1
CONSTRUCTION PLAN
SHEET TITLE
ANDALUSIA LOT 50060
NICOLE & JACQUES ARCHAMBAULT
58892 MARBELLA
LA QUINTA, CA 92253
ANDALUSIA COUNTRY CLUB
PROJECT INFORMATION
NO.REVISIONS DATE BY
1
CONSTRUCTION SPECIFICATIONS
WEBSITE: www.BUBBLESPRINGS.com
POOL
SPA
DECKING
C.K.
SCALE:1/8"=1'-0"
PROJECT #:
PLAN DATE:08/11/2022
PH.760.341.2336
LENGTH:_________WIDTH:_________
MIN DEPTH:______MAX DEPTH:______3'-6"5'-0"
20'-0"10'-0"
SQ.FT: _________PERIMETER:________164 60
MISC. NOTES: ______________________
___________________________________
LENGTH:_________WIDTH:_________
BENCH DEPTH:_____SPA DEPTH:_____21"42"
5'-0"5'-0"
SQ.FT: _________PERIMETER:________25 20
MISC. NOTES: ______________________
___________________________________
DECK 1 TYPE:_______________________
DECK 1 SQ.FT:______________________
DECK 2 TYPE:_______________________
DECK 2 SQ.FT:______________________
DECK 3 TYPE:_______________________
DECK 3 SQ.FT:______________________
POOL AREA COPING
82
COURTYARD AREA
212
COVERED PATIO
341
• ALL ANTI-ENTRAPMENT COVER INSTALLATION MEETING CURRENT
STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND
MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
(ASME)
• EXIT ALARMS TO BE INSTALLED IN ALL DOORS WITH DIRECT ACCESS
TO THE POOL AREA
• CONDUIT AND GAS LINE SHALL BE 18" BELOW FINISHED GRADE.
• NO OVERHEAD UTILITY SERVICE LINE EXISTS.
SAFETY FEATURES
2022 CALIFORNIA BUILDING CODE (BASED ON 2006 IBC)
2022 CALIFORNIA MECHANICAL CODE (BASED ON 2006 UMC)
2022 CALIFORNIA PLUMBING CODE (BASED ON 2009 UPC)
2022 CALIFORNIA ELECTRICAL CODE (BASED ON 2006 NEC)
2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS
REFERENCE CODES
• PER SWIMMING POOL SAFETY ACT 115920 OF THE CALIFORNIA HEALTH
AND SAFETY CODE EFFECTIVE 1-1-2007
SAFETY BARRIER REQUIREMENTS
• EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO
ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC
ART. 680.26. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED.
• PROVIDE ADEQUATE WORK SPACE AROUND
ELECTRICAL EQUIPMENT CED 110.26
ELECTRICAL
TITLE 24, PART 5
•PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY
•ALL DECKING EXPANSION JOINTS FOR REPRESENTATION
ONLY, FIELD LAYOUT WILL VARY
•INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL
COMPLY WITH SECTION 114 - MANDATORY REQUIREMENTS
NORTH
NOTES
MATERIAL SELECTIONS
STONE:
____________________________
TILE:
____________________________
PAVERS:
____________________________
CONCRETE:
____________________________
FIREBOWLS:
____________________________
PEBBLE PLASTER:
____________________________
BOULDERS:
____________________________
UNDERGROUND SERVICE ALERT
A PUBLIC SERVICE BY
BEFORE
YOU DIG
TOLL FREE
DIAL TWO WORKING
DAYS BEFORE
1-800-227-2600
YOU DIG
I HAVE REVIEWED AND I GIVE MY APPROVAL TO
PROCEED WITH THE CONSTRUCTION OF THIS PROJECT
CUSTOMER SIGNATURE DATE
BPOL2022-0337 - 58892 MARBELLA
ARCHAMBAULT / POOL AND SPA AT REAR YARD
POOL AND SPA AT REAR YARD WITH ELECTRICAL OUTLET (1)
AT COURT YARD [ENGINEERED DESIGN]. APPROVED SITE
PLAN AND ENGINEERING REQUIRED ON SITE FOR
INSPECTIONS. THIS PERMIT DOES NOT INCLUDE EQUIPMENT
ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE
INSTALLED AT PRE-PLASTER INSPECTION. 2019 CALIFORNIA
BUILDING CODES.
09/01/2022
Safety Features – New pools and spas shall be equipped with
at least two of the following drowning prevention safety features.
(H&S § 115922 – SB No. 442)
• Enclosure that isolates the pool or spa from dwelling.
• Removable Mesh fencing, a gate that is self-latching and
closing and can accommodate a key lockable device.
• Safety pool cover.
• Exit alarms on doors that provide direct access to pool or spa.
• A self-closing self latching device placed on doors providing
direct access to pool or spa.
• An alarm that when placed in a pool or spa, will sound upon
detection. (Surface Motion, Pressure, Sonar, Laser)
2019 CALIFORNIA BUILDING CODES