BWFE2023-0212BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 04/17/2023 ISSUED DATE: 05/15/2023 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Wall / Fence 58892 MARBELLA BWFE2023-0212 764850031 $25,000.00 Owner:Sunrise LQ, LLC 81570 CARBONERAS, LA QUINTA, CA 92253 Applicant:Nolan Sparks 81570 Carboneras, La Quinta, CA 92253 Contractor:Nolan Sparks / 288130 81570 Carboneras, La Quinta, CA 92253 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 11/4/25 5:50 pm Page 1 of 3 Permit Type: Permit Number: Property Address: Wall / Fence BWFE2023-0212 58892 MARBELLA BUILDING PERMIT SUNRISE / 247LF GARDEN AND 55LF RETAINING WALLS *** 247LF OF 6' GARDEN WALL AT NORTH AND SOUTH PROPERTY LINES, AND EAST FRONT YARD, WITH 55LF OF RETAINING WALL AT WEST PROPERTY LINE [GHANIM ENGINEERING]. THIS PERMIT EXCLUDES ELECTRICAL INSTALLATIONS PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2022 CALIFORNIA BUILDING CODES. Use of Permit Construction Details 302Total Block Wall LF NoPlanning Only Review - (BLDG fees are removed) Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BWFE2023-021 2 $87.55 WALL/FENCE - EA ADDITIONAL 50LF $87.55 $8.00 TECHNOLOGY ENHANCEMENT FEE $8.00 $11.00 RECORDS MANAGEMENT FEE $11.00 $1.00 BSAS SB1473 FEE $1.00 $72.95 WALL/FENCE - FIRST 100LF PC $72.95 $58.36 WALL/FENCE - FIRST 100LF $58.36 $238.86 $238.86 Total for Invoice PERMIT-BWFE2023-0212 Grand Total for Permit $238.86 $238.86 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 04/17/2023 0:00 04/15/2024 12:06 BOND BEAM v.1 Inspection Plan Check v.1 Building Review (1 Day) v.1 Receive Submittal Issue Permit v.1 Contractor / Owner-Builder Information v.1 Generic Action Verify & Invoice Fees v.1 Generic Action Issue Public Works Permit v.1 Create Report Wall / Fence Inspections v.1 Bond Beam v.1 Inspection Footing v.1 Inspection Rough Electrical v.1 Inspection Underground Electrical v.1 Inspection Underground Plumbing v.1 Inspection Final Inspections v.1 04/15/2024 0:00 04/16/2024 11:08 Final Wall / Fence v.1 Inspection 04/15/2024 0:00 04/16/2024 11:08 Printed: 11/4/25 5:50 pm Page 2 of 3 Permit Type: Permit Number: Property Address: Wall / Fence BWFE2023-0212 58892 MARBELLA BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 11/4/25 5:50 pm Page 3 of 3 5/7/2023 BWFE2023-0212 - 58892 MARBELLA SUNRISE / 247LF GARDEN AND 55LF RETAINING WALLS 247LF OF 6' GARDEN WALL AT NORTH AND SOUTH PROPERTY LINES, AND EAST FRONT YARD, WITH 55LF OF RETAINING WALL AT WEST PROPERTY LINE [GHANIM ENGINEERING]. THIS PERMIT EXCLUDES ELECTRICAL INSTALLATIONS PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2022 CALIFORNIA BUILDING CODES. 05/11/2023 WALL REINF. VERT. CORNER BAR TO MATCH SIZE OF VERT. LOCATION OF VERT. & HORIZ. SEE WALL DETAILS FOR SIZE & REINF. IN WALL #4 BAR TO MATCH SPACING OF HORIZ. WALL REINF. 2' - 0 " 2'-0" SEALANT W/ BACKING ROD, FOR REINF., TYP. SEE WALL SECT. TYP. EA. SIDE OF JOINT NOTES: SHOWN EXCEPT BARS @ TOP OF WALL; TOP BARS SHALL BE CONTINUOUS THRU JOINT ( LOCATION OF CONTROL JOINTS ) NEAR WALL INTERSECTIONS AT REGULAR INTERVALS NOT TO EXCEED 40'-0" AT PILASTERS PLAN DETAIL 2. 3. 1. B TOP BARS SEE WALL SECTIONS B TOP OF WALL ELEVATION CUT ALL HORIZ. BARS AS A 2" CL. 2" CL. 3 8" EXPANSION JT. AS OCCURS 2" CL. 2" CL. SE E WA L L SE C T I O N S VERT. BARS EA. SIDE OF JOINT CONTINUOUS SCOPE OF WORK: LIMITED TO STRUCTURAL SITE WALL DESIGN AND DETAILING FOR CONSTRUCTION OF: 1.ONE (1) FREESTANDING CMU WALL 2.ONE (1) FREESTANDING CMU PILASTER REFERENCES THE WORK IS BASED ON THE INFORMATION SET FORTH IN THE FOLLOWING REFERENCES. GEOTECHNICAL INVESTIGATION: SLADDEN ENGINEERING, PROJECT No. 544-18139, FEBRUARY 19, 2020. S-DT0003 12 Ø ( 1 2 " m i n . ) U. N . O . 4"Ø" - 21 2" min LAP IN MASONRY PER CONSTRUCTION NOTE 1 (24"min.) 36Ø LAP IN CONCRETE (18"min.) LAP AND OFFSET 'D'=8d FOR #9 BAR AND LARGER 'D'=6d FOR #8 BAR AND SMALLER "D" BAR BENDS "D" 4" STIRRUP OR TIE " Ø " "D""D" TYPICAL MASONRY WALL STEPPED FOOTING 2 TYPICAL REINFORCING 1 TYPICAL EXPANSION JOINT 3 CMU WALL INTERSECTION 4 DRAINAGE BLOCK-OUT 5 REBAR LOCATION DETAIL 6 STRUCTURAL NOTES - 4"4" CONT. FTG. GENERAL 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS BEFORE COMMENCING WORK AND REPORT ANY DISCREPANCIES. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING, BRACING AND GUYS DURING CONSTRUCTION. SAFETY AND BRACING REQUIREMENTS SHALL BE IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 4.THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH ALL OF THE GENERAL PROVISIONS OF IBC CHAPTER 33 FOR ALL BUILDING AND SITE WORK, DEMOLITION AND CONSTRUCTION. 5.IN ALL CASES WHERE A CONFLICT MAY OCCUR, SUCH AS BETWEEN ITEMS COVERED IN STRUCTURAL SPECIFICATIONS AND NOTES ON THE DRAWINGS OR BETWEEN GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER OF RECORD SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS PRIOR TO INSTALLATION OF THAT PORTION OF WORK. 6.SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK SHOWN ON THE DRAWINGS. 7.PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN PRIOR WRITTEN APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 8.LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OR OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED. IDENTIFY AND LOCATE ANY SUBTERRANEAN UTILITIES PRIOR TO ANY EXCAVATION. 9.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCE OF CONSTRUCTION. TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. NEITHER THE OWNER NOR ARCHITECT/ENGINEER WILL ENFORCE SAFETY MEASURES OR REGULATIONS. CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 10.PROPRIETARY COMPONENTS, MATERIALS, CHEMICAL, EPOXY AND WEDGE ANCHORS AND SHOT PINS SHALL BE EXACTLY AS CALLED FOR IN THESE DRAWINGS. ANY DEVIATIONS SHALL BE APPROVED OR DISAPPROVED BY THE ENGINEER OF RECORD AT THE EXPENSE OF THE ENTITY REQUESTING THE SUBSTITUTION PRIOR TO INSTALLATION. 11.THE CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR COORDINATION AND ASSEMBLY OF ALL PARTS OF THE CONSTRUCTION DEPICTED HEREIN. THE CONTRACTOR SHALL PERFORM ANY CONSTRUCTABILITY REVIEW OR COORDINATION DRAWINGS NECESSARY TO IDENTIFY CONSTRUCTABILITY PROBLEMS PRIOR TO CONSTRUCTION. GEOTECHNICAL NOTES: 1.GEOTECHNICAL INVESTIGATION: SLADDEN ENGINEERING, PROJECT No. 544-18139, FEBRUARY 19, 2020. 2.FOUNDATION MATERIAL: APPROVED FILL PER GEOTECHNICAL INVESTIGATION. 3.MINIMUM FOUNDED DEPTH OF FOOTINGS: BELOW ROUGH PAD GRADE 12" BELOW LOWEST ADJACENT FINISHED GRADE 12" 4.FOUNDING OF FOOTINGS & SLABS: ON APPROVED COMPACTED SOILS AS NOTED IN GEOTECHNICAL INVESTIGATION. CONCRETE AND REINFORCING NOTES (CODE CHAPTER 19): 1.CONTRACTOR TO PROVIDE CONCRETE MIX DESIGNS FROM AN APPROVED LABORATORY OR FROM THE CONCRETE SUPPLIER PREPARED UNDER THE SUPERVISION OF, SIGNED, AND SEALED BY A CALIFORNIA REGISTERED ARCHITECT, CIVIL OR STRUCTURAL ENGINEER. 2.REINFORCEMENT: A)DETAILING, FABRICATION AND PLACING: SHALL CONFORM TO ACI315 AND ACI318. CERTIFICATION AND TESTING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF ASTM STANDARDS. B)MINIMUM CONCRETE COVER: CAST AGAINST & EXPOSED TO EARTH 3" EXPOSED TO EARTH OR WEATHER 2" NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS 3/4" BEAMS, COLUMNS (TIES, STIRRUPS, SPIRALS)1-1/2" C)CHAIRS, SPACERS AND AND PLATES: AS REQUIRED TO MAINTAIN CONCRETE COVER. D)VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING MEMBERS WITH THE SAME SIZE AND SPACING OF REINFORCEMENT AS SHOWN IN THE DRAWINGS AND GENERAL NOTES. E)SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT IN A LAYER SHALL NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF THE REINFORCEMENT, OR 1-1/3 TIMES MAXIMUM SIZE AGGREGATE, NOR LESS THAN 1-1/2". F)TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT PERMITTED UON. G)SPLICES (STANDARD LAPS): AS SCHEDULED, 40 DIAMETERS OR 24 INCHES WHICHEVER IS GREATER UON ON DRAWINGS. STAGGER BOTTOM SPLICES AT LEAST 5'-0" FROM SPLICES IN OTHER BOTTOM REINFORCEMENT. STAGGER SPLICES FOR TOP REINFORCEMENT SIMILARLY. 3.PIPES, SLEEVES AND DUCTS: NOT TO BE PLACED IN WALLS, BEAMS, SLABS, FOOTINGS OR COLUMNS UNLESS SPECIFICALLY DETAILED. 4.ADMIXTURES: REVIEWED BY THE ENGINEER OF RECORD. CALCIUM CHLORIDE OR ADDED CHLORIDES ARE NOT PERMITTED. FLY ASH SHALL NOT BE PERMITTED IN CONCRETE MIXTURES. 5.CONSTRUCTION JOINTS: ACI 360R, 1/4-INCH AMPLITUDE MINIMUM OR KEYED JOINTS PER PLAN. LOCATION OF JOINTS TO BE REVIEWED BY THE ENGINEER OF RECORD PRIOR TO PLACEMENT OF REINFORCEMENT. 6.CONCRETE CURING: ACI 302.1R. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE DAYS AFTER ITS PLACEMENT. FOR CONCRETE OTHER THAN SLAB ON GRADE, APPROVED CURING COMPOUNDS MAY BE USED IN LIEU OF MOIST CURING, IF APPROVED BY THE OWNER AND ARCHITECT. 7.VIBRATION: ALL CONCRETE SHALL BE CONSOLIDATED WITH MECHANICAL VIBRATORS IN ACCORDANCE WITH GENERAL PROVISIONS OUTLINED IN ACI 309R. REBAR CMU FACE SHELL CLEAR DIMENSION RETAINED EARTH RETAINING WALL ℄ DIMENSION CONSTRUCTION NOTES: 1.REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS, UIO. SEE DETAIL 2.JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD-DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3.PROVIDE NORMAL WEIGHT CONCRETE (145 PCF) WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05%, ATTAINING MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS. 4.CONCRETE MUST BE CAST DIRECTLY AGAINST UNDISTURBED SOIL, UIO BY SOILS REPORT. 5. PROVIDE MASONRY UNITS OF MEDIUM WEIGHT CLASSIFICATION COMPLYING WITH ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE-AND-GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 6.MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 2000psi. 7.GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 8.FIRST COURSE MAY BE WET-SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 9.CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS U.N.O. 10.VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED SEE DETAIL 11.GROUT ALL CELLS WITH REINFORCEMENT U.I.O. 12.INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 13.FOR TYPICAL REINFORCING AT WALL INTERSECTIONS SEE DETAIL 14.FOR TYPICAL FOOTING STEP SEE DETAIL 15.FOR TYPICAL DRAINAGE BLOCK-OUT SEE DETAIL 16.CLEAR (CLR.) OR CENTERLINE WHERE REFERENCED TO VERTICAL REINFORCING PER DETAIL 17.RETAINING WALL BACKFILL SHOULD CONSIST OF SANDY SOILS THAT MUST MEET AT LEAST ONE OF THE FOLLOWING CRITERIA: A. A SAND EQUIVALENT (SE) OF 30 OR GREATER PER CALIFORNIA TEST METHOD (CTM) 217, OR B. A MAXIMUM OF 35 PERCENT FINES (PASSING THE NO. 200 SIEVE) PER AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D 421/422 AND AN EXPANSION INDEX OF 20 OR LESS. RETAINING WALL BACKFILL SHOULD ALSO BE LIMITED TO FILL MATERIAL NOT EXCEEDING 3 INCHES IN GREATEST DIMENSION. SEE GEOTECHNICAL INVESTIGATION FOR ADDITIONAL RECOMMENDATIONS. 18.SEE SOILS REPORT FOR THE HORIZONTAL LIMITS OF SAND BACKFILL REQUIRED. 19. WALLS HAVE NOT BEEN DESIGNED FOR SURCHARGE RESULTING FROM VEHICULAR TRAFFIC OR ADJACENT FOOTINGS U.I.O. 20. EXCAVATION FOR WALL/ FOUNDATION SHALL NOT UNDERMINE ANY ADJACENT STRUCTURES. TEMPORARY SHORING AND STABILIZATION OF ADJACENT STRUCTURES SHALL BE PROVIDED BY THE CONTRACTOR AS REQUIRED 1 - 2 - 2 - 5 - 4 - 6 - 1' - 0 " MI N . ST E P 6" O R 8 " PE R C M U BL K . H T . 3" CLR. TYP. . 1'-0" STEP STEPSTEP CMU WALL PER DETAILS (TYP. REINF. NOT SHOWN FOR CLARITY) ALIGN CONTROL JOINT AT STEP WHERE OCCURS 40'-0"o.c. MAX. DOWELS AND DROP-IN BARS AT CELL EACH SIDE OF STEP AND CONTROL JOINT TYP. TOP BARS WHERE OCURRING #4 HORIZ. CONT. w/ 24" MIN. LAP FINISHED GRADE FRONT FACE WALL FOOTING CHANGE OF WALL THICKNESS TYP. CHANGE OF WALL HEIGHT & FOOTING SIZE TYP. LAYOUT LINE MASONRY CAP TYP. WHERE OCCURRING EXTEND CAULKING 6" MIN. BELOW FINISH GRADE TYP. EXPANSION JOINT WHERE OCCURRING PLACE AT 40'-0"o.c. MAX. EXPANSION JOINT WHERE OCCURRING TYPICAL WALL ELEVATION - MASONRY CONSTRUCTION TYPICAL WALL PLAN - MASONRY CONSTRUCTION 3B - TYP. STRUCTURAL STEEL 1.STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS. PLATES AND BARS - ASTM A36, Fy=36 ksi, Fu=58 ksi. 2.FASTENERS FOR STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS. NUTS - ASTM A563. WASHERS - ASTM F436. THREADED RODS - ASTM F1554, GRADE 36. SITE WALLS STANDARD DETAILS S-0 DESIGN CRITERIA: 1.DESIGN CRITERIA PER 2022 CBC AND GEOTECHNICAL RECOMENDATIONS 2.ALLOWABLE SOIL BEARING PRESSURE = 1800 PSF (WITH INCREASE PER SOILS REPORT) 3.ALLOWABLE SOIL PASSIVE PRESSURE = 250 PCF 4.COEFFICIENT OF FRICTION = 0.40 5.LEVEL ACTIVE PRESSURE = 35 PCF 6.AT-REST PRESSURE = 55 PCF 7.MASONRY COMPRESSIVE STRENGTH, f'm = 2000 PSI. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2 EXCEPTION 2, 'U' OCCUPANCY. LOADING: 1.SEISMIC, 5% DAMPING @ 1 SECOND ACCELERATION Cs= 0.800Wt. 2.DESIGN WIND = EXP. C @ 110 MPH GATE JAMB DETAIL 7- SHEET INDEX S-0: STANDARD DETAILS / STRUCTURAL NOTES S-5.0:STRUCTURAL WALL DETAILS 2 - DWLs. @ EA. SIDE OF BLOCK-OUT w/ 2 - DROP-IN BARS, MATCH SIZE OF TYP. REINF. 8"x8" BLOCK-OUT SPACED @32" O.C. MIN. NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURS, A 1/2 BLK. MAY BE LEFT OUT AT SWALE GRADE. PROVDE DWL. & DROP-IN BAR ON EA. SIDE OF THE 1/2 BLK. DRAIN AS SHOWN. MASONRY WALL SYSTEM CMU FREE-STANDING FENCE WALL ELEVATION 1'-4"TYP. CMU WALL & FTG. PER 1 S-5.0 10" 8" PROJECT DESCRIPTION: OWNER: ENGINEER OF RECORD: 898 N. FAIR OAKS AVE. STE. F PASADENA, CA 91103 626.407.2224 GSE JOB #: 23-081 SITE WALLS THIS DRAWING IS THE SOLE PROPERTY OF GSE AND IS INTENDED FOR USE ONLY FOR THE PROJECT LISTED IN THE TITLE BLOCK. THIS DOCUMENT AND CONTENTS MAY NOT BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR ASSIGNED TO ANY THIRD PARTY WITHOUT WRITTEN PERMISSION BY GSE SHEET TITLE: SHEET NUMBER: DRAWN BY: D.E. HYLTON PROJECT NUMBER: 23-081 DATE: 05 / 05 / 2023 AN D A L U S I A 58 8 9 2 M A R B E L L A LA Q U I N T A , C A 2'-8" SQ. 2 - #4 VERT. DOWELS AND DROP-IN BARS EA. SIDE OF GATE. SOLID GROUT CELLS 4 - #4 EA. WAY AT BOTTOM 12"x8" CONT. FTG. THROUGH GATE OPENING TYP. FTG. REINF. 3'-6" MAX. GATE OPENING 3" CLR. TYP. 05/11/2023 SITE WALLS WALL DETAILS S-5.0SEE SHEET S-0 FOR STANDARD NOTES AND DETAILS. 6" CMU WALL 1N.T.S. MASONRY WALL SYSTEM FREE-STANDING 6" CMU FENCE WALL TRENCH FOOTING 'H ' M A X . PE R S C H E D U L E 4" MI N . 'D ' M I N . PE R S C H E D U L E 3" C L R . TY P . 8" CONT. 6" WIDE (NOM.) CMU. GROUT CELLS w/ REINF. DWLS. TO MATCH VERT. REINF. LAP 24" MIN. F.G. WET-SET FIRST COURSE PER CONSTRUCTION NOTE 8 #4 CONT. T&B CONT. CONC. FTG. 'X' BARS PER SCHEDULE AT CTR. OF WALL OPTIONAL WALL CAP #6 STD. LADDER TYPE (#5 STD. FOR SLUMPSTONE) REINF. AT TOP COURSE, AT FIRST COURSE, AND 16" O.C. #4 CONT. @12" O.C. MASONRY WALL SCHEDULE 'H' MAX.'X' BARS'D' MIN. 2'-4"#4@32" O.C.6'-8" 1'-7"#4@48" O.C.4'-0" DETAIL - DETAIL - DETAIL - DETAIL - 16" CMU PILASTER 2N.T.S. ANGELUS BLOCK MASONRY WALL SYSTEM CMU FREE-STANDING PILASTER SPREAD FOOTING 12 " MI N . A 4' - 0 " M A X . 16" SQ. (NOM.) CMU PILASTER, SOLID GROUT DWLS. TO MATCH VERT. REINF. LAP 24" MIN. 3"3"OUTSIDE FACE OF BLOCK TO ℄ OF VERT OUTSIDE FACE OF BLOCK TO ℄ OF VERT 4 - #4 VERT. BARS F.G. WET-SET FIRST COURSE PER CONSTRUCTION NOTE 8 12 " MI N . 2'-9" SQ. MIN. . 3" CLR. TYP. CONC. FTG. 4 - #4 EA. WAY AT BOTTOM #3 TIES PER ELEVATION A 'W'=16" SQ. 16x8x16 or 16x6x16 (NOM.) CMU PILASTER 3" CLR. TYP. PILASTER SECTION 4 - #4 VERT. BARS . OPTIONAL WALL CAP #3 TIES @ TOP COURSE, AT FIRST COURSE, AND 16" O.C. EQ.EQ. SEE SHEET S-0 FOR STANDARD NOTES AND DETAILS. PROJECT DESCRIPTION: OWNER: ENGINEER OF RECORD: 898 N. FAIR OAKS AVE. STE. F PASADENA, CA 91103 626.407.2224 GSE JOB #: 23-081 SITE WALLS THIS DRAWING IS THE SOLE PROPERTY OF GSE AND IS INTENDED FOR USE ONLY FOR THE PROJECT LISTED IN THE TITLE BLOCK. THIS DOCUMENT AND CONTENTS MAY NOT BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR ASSIGNED TO ANY THIRD PARTY WITHOUT WRITTEN PERMISSION BY GSE SHEET TITLE: SHEET NUMBER: DRAWN BY: D.E. HYLTON PROJECT NUMBER: 23-081 DATE: 05 / 05 / 2023 AN D A L U S I A 58 8 9 2 M A R B E L L A LA Q U I N T A , C A DETAIL - DETAIL - DETAIL - DETAIL - 05/11/2023 05/11/2023 05/11/2023 05/11/2023