Loading...
BSOL2023-0084BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 02/22/2023 ISSUED DATE: 07/06/2023 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 53325 HUMBOLDT BLVD BSOL2023-0084 767700013 $41,000.00 Owner:LAURA WELLMAN 27412 ALISO VIEJO PKWY, ALISO VIEJO, CA 92656 Applicant:Vin Barba 933 NEWHALL STREET, COSTA MESA, CA 92627 Contractor:Vin Barba / 1029267 933 NEWHALL STREET, COSTA MESA, CA 92627 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 11/20/25 9:36 am Page 1 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2023-0084 53325 HUMBOLDT BLVD BUILDING PERMIT WELLMAN/16.465 KW PV SYSTEM WITH BATTERY BACK UP *** LOT 61, ORIENTATION 180 DEGREES - 16.465kWDC SOLAR ARRAY - (37) 445W URE FBM445M7G-BB MODULES, (37) ENPHASE IQ8M-72-US MICROINVERTERS,TESLA POWERWALL BATTERIES (2), ENPHASE COMBINER BOX, AND EXISTING 200A BACK UP LOAD CENTER (862SF). 2022 CALIFORNIA ELECTRICAL CODE. Use of Permit Construction Details 16.465System Size (kW DC)4PV Strings (EA)4PV Miscellaneous Equipment EA Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. PERMIT-BSOL2023-008 4 $11.00 RECORDS MANAGEMENT FEE $11.00 $8.00 TECHNOLOGY ENHANCEMENT FEE $8.00 $116.72 PV SYSTEM MISC EQUIPMENT PC $116.72 $116.72 PV SYSTEM MISC EQUIPMENT $116.72 $43.77 PV SYSTEM GREATER THAN 10KW PC $43.77 $110.88 PERMIT ISSUANCE $110.88 $2.00 BSAS SB1473 FEE $2.00 $43.77 PV SYSTEM GREATER THAN 10KW $43.77 $10.52 2.5 CREDIT CARD PROCESSING FEE $10.52 $463.38 $463.38 Total for Invoice PERMIT-BSOL2023-0084 Grand Total for Permit $463.38 $463.38 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 Submittal Document Verification v.1 Generic Action Plan Check v.1 Building Review (1 Day) v.1 Receive Submittal Permit Issuance v.1 Verify Contractor info & Conditions have been met v.1 Generic Action Verify & Invoice Fees v.1 Generic Action Verify Fee Payment & Issue Permit v.1 Generic Action Print, Attach, and Email Building Permit v.1 Create Report Solar Inspections v.1 Rough Electrical v.1 Inspection Rough Plumbing v.1 Inspection Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 11/13/2023 0:00 11/15/2023 12:00 Solar Final v.1 Inspection 11/13/2023 0:00 11/15/2023 12:00 Printed: 11/20/25 9:36 am Page 2 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2023-0084 53325 HUMBOLDT BLVD BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 11/20/25 9:36 am Page 3 of 3 MS P RS D AT S CL C BAT2 EN C DRIVEWAY PROP E R T Y L I N E PROPERTY LINE HU M B O L D T B L V D LADDER ACCESS PR O P E R T Y L I N E AC D 3 BAT1 ACD 1 ACD 2 SI T E P L A N Pr o j e c t N a m e a n d A d d r e s s 93 3 N e w h a l l s t Co s t a M e s a C A 9 2 6 2 7 (9 0 8 ) 4 8 9 - 3 9 3 3 Li c # 1 0 2 9 2 6 7 Cl a s s B , C - 4 6 X_ _ _ _ _ _ _ _ _ _ _ _ _ _ BR I G H T L I F E S O L A R Vi n B a r b a , B , C - 4 6 BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13D. R324.6.2.1 - WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH NFPA 13D OR SECTION P2904, SETBACKS AT RIDGES SHALL COMPLY WITH ONE OF THE FOLLOWING: 1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN AN 18-INCH (457 MM) CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN A 36-INCH (914 MM) CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. ALL WORK TO COMPLY WITH 2022 CALIFORNIA BUILDING CODE: 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA ENERGY CODE 2022 LA QUINTA MUNICIPAL CODE AND MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS. INSPECTION REQUIRED FOR ROOF CONNECTION MOUNTING ASSEMBLIES PRIOR TO INSTALLING SOLAR MODULE. PHOTOVOLTAIC SYSTEM'S FIRE CLASSIFICATION MUST BE CLASS A ROOFING MATERIAL PER SECTIONS R902.3 OR R904.4 AND PER AMENDED TABLE 1501.1 NBMC TESTING, LISTING AND IDENTIFICATION COMPLIES WITH UL 1703 AS REQUIRED PER SECTION R902.4 PHOTOVOLTAIC SYSTEM'S INSTALLATION SHALL BE PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS MINIMUM 3 FEET WORKING CLEARANCES IN FRONT OF ALL SOLAR-VOLTAIC EQUIPMENT MINIMUM 3 FEET HORIZONTAL SETBACK FROM GAS METER SHALL BE MAINTAINED ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR WET LOCATIONS. INTEGRATED GROUNDING CLAMPS TO BOND MODULES TO MOUNTING RAILS. PER MANUFACTURER. LEGEND AERIAL IMAGE MSP ENC RSD A1 CLC NEW ENPHASE AC COMBINER BOX WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM GENERAL NOTES SYSTEM SUMMARY ROOF CALCULATION FIRE SAFETY ACCESS MINIMUM 3' WIDE PLANS PREPARED BY VINCENZO BARBAHDHEAT DETECTOR ATS NEW TESLA GATEWAY 2 AUTOMATIC TRANSFER SWITCH WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM BAT1 A1 LOCATION OF HEAT ALARM DEVICE DOES NOT EXCEED THE TEMPERATURE OR CONDITION LIMITATION OF THE MANUFACTURER'S DEVICE LISTING. FIRE DETECTION SHALL BE PROVIDED IN ROOMS AND AREAS WITHIN DWELLING UNITS, BASEMENTS AND ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE PROTECTED BY SMOKE ALARMS IN COMPLIANCE WITH SECTION R314 OF THE 2019 CALIFORNIA RESIDENTIAL CODE. SEE ATTACHED HEAT DETECTOR SPECIFICATIONS SHEET FOR LISTING AND TYPE OF DEVICE ADDITIONAL NOTES HD Sheet Scale:N.T.S PV-01 Date: Drawing: Th e M a d i s o n C l u b Madison Club AP N 7 7 9 - 4 4 0 - 0 1 3 , L O T # 6 1 B 53 3 2 5 H u m b o l d t B o u l e v a r d La Q u i n t a , C A , 9 2 2 5 3 12/14/22 ROOF: 37 PANELS PENETRATION SPACING: 64" MAX PV ROOF AREA : 8,055.3 SQ. FT. PV AREA: 861.82 SQ. FT. PV PANEL WEIGHT= 53.35 LBS MOUNTING HARDWARE WEIGHT= 185 LBS ENTIRE WEIGHT ON ROOF: [(53.35LBS)X(37)]+185= 2,158.95 LBS 2,158.95 LBS/ 791.94 SQ. FT. = 2.505 LBS PER SQ. FT. 2,158.95 LBS/ 50 ATTACHMENTS = 43.18 LBS PER ATTACHMENT TOTAL ROOF AREA: 12,253.13 PV AREA: 861.82 PV COVERAGE: 7.03% RIDGE SETBACK REQUIRED: 18" ESS AND PV REMOTE DISABLE SWITCH WITHIN 3' OF MAIN SERVICE PANEL BAT2 EXISTING 600 AMP MAIN ELECTRICAL PANEL WALL MOUNTED IN MECHANICAL ROOM EXISTING 200 AMP SUB ELECTRICAL PANEL TO BE USED AS BACKUP PANEL WALL MOUNTED IN ELECTRICAL ROOM NEW TESLA POWERWALL BATTERY (NEMA 3R, UL LISTED 5KW, 13.5 KWH) WALL MOUNTED IN MECHANICAL ROOM AT 6" ABOVE FINISHED FLOOR (37) UL LISTED PV MODULES AT 180° AZIMUTH. MOUNTED AT 0° PARALLEL TO ROOF SURFACE ON FIRST STORY. 8,055.3 SQ FT DC PV SIZE: 16.465 kW AZIMUTH: 180 NUMBER OF PV MODULES: 37 PV MODEL #: FBM445M7G-BB URE 445W MODULE HEIGHT: 75.12" MODULE WIDTH: 44.65" MODULE WEIGHT: 53.35 LBS INVERTER MODEL #: (37) IQ8M-72-2-US (240V) BATTERY MODEL: (2) TESLA POWERWALL 2 PV STRUCTURE: FASTJACK / IRONRIDGE ROOF TYPE: TPO NUMBER OF STORIES:1 STORY ROOF TILT: 0 ROOF FRAMING: 2 X 4 ROOF TRUSSES 24" O.C. SPACING STRUCTURE TYPE: SFR NUMBER OF ROOFS USED: 1 OCCUPANCY GROUP: R3/U CONSTRUCTION TYPE: VB # OF ATTACHMENTS: 40 SHEET INDEX PV-01 PV-02 PV-03 PV-04 SITE PLAN PROJECT NOTES STRUCTURAL DETAILS ELECTRICAL LAYOUT SECTION PLAN TYPICAL CONNECTION DETAIL ELECTRICAL WIRING DIAGRAM WIRE SIZE CALCULATIONS BACKUP LOAD CALCS WARNING LABELS ELECTRICAL ELEVATION ACD 1 NEW 200A AC DISCONNECT WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM NEW TESLA POWERWALL BATTERY (NEMA 3R, UL LISTED 5KW, 13.5 KWH) WALL MOUNTED IN MECHANICAL ROOM AT 6" ABOVE FINISHED FLOOR ACD 2 NEW 30A AC DISCONNECT FOR BATTERY WALL MOUNTED IN UNINHABITABLE MECHANICAL ROOM ACD 3 NEW 30A AC DISCONNECT FOR BATTERY WALL MOUNTED IN UNINHABITABLE MECHANICAL ROOM HD BSOL2023-0084 - 53325 HUMBOLDT BOULEVARD WELLMAN/16.465 KW PV SYSTEM WITH BATTERY BACK UP LOT 61, ORIENTATION 180 DEGREES - 16.465kWDC SOLAR ARRAY - (37) 445W URE FBM445M7G-BB MODULES, (37) ENPHASE IQ8M-72-US MICROINVERTERS,TESLA POWERWALL BATTERIES (2), ENPHASE COMBINER BOX, AND EXISTING 200A BACK UP LOAD CENTER (862SF). 2022 CALIFORNIA ELECTRICAL CODE. 07/06/2023 MS P RS D AT S CL C EN C R AC D BAT2 ACD BAT2 ACD JB MS P RS D AT S CL C EN C111111111113344 3 3 3 322222222222 P FMC 4 444 AC D BAT2 ACD BAT2 ACD 444 TPO FLASHING SOLAR MODULE STAINLESS STEEL 3/8" HARDWARE MODULE CLAMP MOUNTING RAIL 6" PROSOLAR FASTJACK ROOF RAFTER 5/16" x 3 1/2" STAINLESS STEEL LAG SCREW PENETRATION 72" O.C. MAX SPACING ST R U C T U R A L D E T A I L S EL E C T R I C A L L A Y O U T SE C T I O N P L A N TY P I C A L C O N N E C T I O N D E T A I L PV LAYOUT PLAN SECTION PLAN Pr o j e c t N a m e a n d A d d r e s s ELECTRICAL LAYOUT PLANS PREPARED BY: VINCENZO BARBA 93 3 N e w h a l l s t Co s t a M e s a C A 9 2 6 2 7 (9 0 8 ) 4 8 9 - 3 9 3 3 Li c # 1 0 2 9 2 6 7 Cl a s s B , C - 4 6 X_ _ _ _ _ _ _ _ _ _ _ _ _ _ BR I G H T L I F E S O L A R Vi n B a r b a , B , C - 4 6 TYPICAL CONNECTION DETAIL EXISTING 2 X 4 ROOF TRUSSES AT 24" O.C .SPACING. MOUNTING BRACKETS PV MOUNTING RAILS WITH BRACKETS AT 72" O.C. MAX SPACING. R JB P PAINT COLOR MATCH ALL EXPOSED CONDUIT TO ADJACENT SURFACE COLOR NEMA 3R JUNCTION BOX MICROINVERTER IN BRANCH # UNDER EACH PANEL NEW FMC CONDUIT FOR WIRING RUN WITHIN ATTIC AND WALLS # FMC Sheet Scale:N.T.S PV-02 Date: Drawing: Th e M a d i s o n C l u b Madison Club AP N 7 7 9 - 4 4 0 - 0 1 3 , L O T # 6 1 B 53 3 2 5 H u m b o l d t B o u l e v a r d La Q u i n t a , C A , 9 2 2 5 3 12/14/22 07/06/2023 Pr o j e c t N a m e a n d A d d r e s s PLANS PREPARED BY: VINCENZO BARBA 93 3 N e w h a l l s t Co s t a M e s a C A 9 2 6 2 7 (9 0 8 ) 4 8 9 - 3 9 3 3 Li c # 1 0 2 9 2 6 7 Cl a s s B , C - 4 6 X_ _ _ _ _ _ _ _ _ _ _ _ _ _ BR I G H T L I F E S O L A R Vi n B a r b a , B , C - 4 6 NOTES -MICROINVERTER HOUSING IS DESIGNED FOR OUTDOOR INSTALLATION AND COMPLIES WITH NEMA 6 ENVIRONMENTAL ENCLOSURE RATING STANDARD. -ENPHASE ENGAGE CABLE SPECS: +CABLE TEMPERATURE RATING.......... 90 C WET +CABLE INSULATOR RATING............... THWN-2 +UV EXPOSURE RATING..................... UL746 C, F1 +CONDUCTOR GAUGE......................... 12 AWG +MAXIMUM CURRENT CARRYING CAPACITY OF THE ENGAGE CABLE..... 20AMPS INTEGRATED GROUNDING CLAMPS TO BOND MODULES TO MOUNTING RAILS. PER MANUFACTURER. INSTALLATION MEETS THE NEC, ART 690 ENPHASE MICROINVERTER. INSTALLATION PER MANUFACTURER MANUAL. SEE ATTACHED. INVERTERS UL1741 COMPLIANT ANY EXPOSED WIRING IS RATED USE-2 SUNLIGHT RESISTANT ALL CONDUCTORS ARE 90 C DEGREE RATED. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR WET LOCATIONS. ENPHASE MICROINVERTER HAS DC CIRCUIT THAT IS ISOLATED AND INSULATED FROM GROUND, SO NO GEC IS REQUIRED PER MANUFACTURER. Inverter maximum output current X 1.25 = (BAac) and maximum AC overcurrent amperage rating 1.35A X 1.25 = 1.6875 A 1.6875 A X 11 (# of inverters in branch) = 18.56 A #10 awg THHN/THWN-2 wire = 40A (per 310.16 & 334.80) X 0.71 ambient temperature correction factor (Table 310.16) = 28.4A 28.4 x 0.8 fill factor (per table 310.15(B)(2)(a) 4-6 current carrying conductors) = 22.72 A result > or = to BAac (18.56 A) and less than the entry for 310.16 for runs greater than 3% VD. Breaker for each solar circuit: 20A 1.6875 A X 37 (CIRCUITS) = 64.125 A #4 awg THHN/THWN-2 wire = 95A (per 310.16) X 0.89 ambient temperature correction factor (Table 310.16) = 84.55A result > or = to BAac (64.125 A) and less than the entry for 310.16 for runs greater than 3% VD. Breaker for combined solar circuit: 70A EXISTING 600 AMP MAIN ELECTRICAL PANEL WALL MOUNTED IN ELECTRICAL ROOM TERMINATOR CAP INSTALLED AT END OF CABLE NEMA 3R JUNCTION BOX BACKUP LOADS BACKUP LOADS EXISTING 200 AMP SUB ELECTRICAL PANEL TO BE USED AS BACKUP PANEL WALL MOUNTED IN ELECTRICAL ROOM NEW -(8) #10 AWG THHN/THWN-2 WIRE -(1) #8 AWG THHN/THWN-2 GROUND WIRE -IN NEW 3/4" FMC CONDUIT WITHIN ATTIC AND WALLS NEW -1/O AL SER CABLE IN WITHIN WALLS INVERTER: (37) ENPHASE MICROINVERTERS MODEL #: IQ8M-72-2-US (240V) MODULES: (37) FBM445M7G-BB URE 445W AFCI PROTECTION WILL BE PROVIDED PER 210.12 FOR RELOCATED WIRI ESS AND PV REMOTE DISABLE SWITCH WITHIN 3' OF MAIN SERVICE PANEL ENPHASE Q CABLE. OUTDOOR RATED WITH INTEGRATED CONNECTORS FOR MICROINVERTERS. WITH (3) 12AWG CONDUCTORS ENPHASE Q CABLES: BLACK - L1 RED - L2 GREEN-GROUND (1) #6 BARE COPPER GROUND WIRE IN FREE AIR FOR MODULES AND RACKING WIRING CALCULATION COMBINED SOLAR CALCULATION WIRE KEY NEW PV EQUIPMENT EQUIPMENT KEY METER SOCKET N EXISTING GROUNDING ELECTRODE IRREVERSIBLE GROUNDING CONNECTION CCT CLC BAT1 MSP NEW 10/3 ROMEX TYPE NM-B WIRING IN WALLS ATS CLC BAT1 RSD MSP BACKUP LOAD CALCS EL E C T R I C A L W I R I N G D I A G R A M WI R I N G C A L C U L A T I O N BA C K U P L O A D C A L C U L A T I O N Sheet Scale:N.T.S PV-03CCTPCTPRODUCTION CT's CONSUMPTION CT's + -- + - E E + - + - E E (11) ENPHASE MICROINVERTERS IN A SINGLE BRANCH CIRCUIT TO NEW ENPHASE ENPOWER (N) 70 AMP CTRL (N) 30 AMP ATS NEW TESLA POWERWALL BATTERY (NEMA 3R, UL LISTED 5KW, 13.5 KWH) WALL MOUNTED IN MECHANICAL ROOM AT 6" ABOVE FINISHED FLOOR NEW -(3) #6 AWG THHN/THWN-2 WIRE -(1) #8 AWG THHN/THWN-2 GROUND WIRE -IN 3/4" FMC CONDUIT WITHIN WALLS AUX RDCBBATTERY COMMUNICATIONS REMOTE DISABLE COMMUNICATIONS RDC PCT PCT B CCT NEW (4) [24-16] AWG THWN-2 B RSD RDC 20 AMP20 AMP ENPHASE MONITORING 20 AMP TO 1 CONSUMPTION CT BAT2 NEW (4) [24-16] AWG THWN-2 B 600A EXISTING 600 AMP MAIN BREAKER (N) 30 AMP + -- + - E E + - + - E E (11) ENPHASE MICROINVERTERS IN A SINGLE BRANCH CIRCUIT TO NEW ENPHASE ENPOWER + -- + - E E + - + - E E (9) ENPHASE MICROINVERTERS IN A SINGLE BRANCH CIRCUIT TO NEW ENPHASE ENPOWER BAT2 NEW TESLA GATEWAY 2 AUTOMATIC TRANSFER SWITCH WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM15 AMP ENC NEW ENPHASE AC COMBINER BOX WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM + -- + - E E + - + - E E (6) ENPHASE MICROINVERTERS IN A SINGLE BRANCH CIRCUIT TO NEW ENPHASE ENPOWER Date: Drawing: Th e M a d i s o n C l u b Madison Club AP N 7 7 9 - 4 4 0 - 0 1 3 , L O T # 6 1 B 53 3 2 5 H u m b o l d t B o u l e v a r d La Q u i n t a , C A , 9 2 2 5 3 12/14/22 ACD 3 NEW 200 AMP AC DISONNECT WALL MOUNTED IN UNINHABITABLE ELECTRICAL ROOM 20 AMP PV BATTERY BATTERY 120 AMP NEW 120 AMP BREAKER FOR GATEWAY TO BE MOUNTED AT OPPOSITE END OF BUSBAR FROM MAIN BREAKER NEW TESLA POWERWALL BATTERY (NEMA 3R, UL LISTED 5KW, 13.5 KWH) WALL MOUNTED IN MECHANICAL ROOM AT 6" ABOVE FINISHED FLOOR ACD 3 ACD 2 ACD 1 ACD 1 NEW 30 AMP AC DISONNECT FOR BATTERY WALL MOUNTED IN UNINHABITABLE MECHANICAL ROOM ACD 2 NEW 30 AMP AC DISONNECT FOR BATTERY WALL MOUNTED IN UNINHABITABLE MECHANICAL ROOM PCS CONTROLLED CURRENT SETTING: 120 A THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION 07/06/2023 ESS AND PV REMOTE DISABLE SWITCH WITHIN 3' OF MAIN SERVICE PANELM EXISTING 600 AMP MAIN ELECTRICAL SERVICE PANEL TESLA GATEWAY 200 AMP INTERIOR SUB PANEL TO BE USED AS BACKUP PANEL ENPHASE COMBINER CE N T E R W A L L CE N T E R W A L L GRADE WALL LIMIT TO ROOF GRADE WALL LIMIT TO ROOF LE F T W A L L LE F T W A L L RI G H T W A L L RI G H T W A L L ELECTRICAL ROOM INTERIOR AC DISONNECT WITHIN 3' OF MAIN SERVICE PANEL NEMA 3R JUNCTION BOX ON ROOF ARRAY ON ROOF TESLA POWERWALL GRADE WALL LIMIT TO ROOF MECHANICAL ROOM INTERIOR BATTERY AC DISONNECT TESLA POWERWALL BATTERY AC DISONNECT Pr o j e c t N a m e a n d A d d r e s s PLANS PREPARED BY: VINCENZO BARBA 93 3 N e w h a l l s t Co s t a M e s a C A 9 2 6 2 7 (9 0 8 ) 4 8 9 - 3 9 3 3 Li c # 1 0 2 9 2 6 7 Cl a s s B , C - 4 6 X_ _ _ _ _ _ _ _ _ _ _ _ _ _ BR I G H T L I F E S O L A R Vi n B a r b a , B , C - 4 6 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SOLAR PHOTOVOLTAIC ON ROOF LABELS AT EVERY 10 FEET OF CONDUIT AND AT JUNCTION BOX WARNING LABELS WARNING: PHOTOVOLTAIC POWER SOURCE -ALL LABELS PER NEC, ART 690 & CEC FORMAT: -WHITE LETTERING ON RED BACKGROUND -MINIMUM 3/8 INCH LETTERING -ALL LETTERS SHALL BE CAPITALIZED -ARIAL FONT REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. DURABLE ADHESIVE MATERIALS DISCONNECT DIRECTORY PLAQUE AT MAIN PANEL THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY & SOLAR) WARNING: POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION [CEC 690.64(B)(4)] LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES [CEC 706.15] LABEL AT BATTERY DISCONNECT SWITCH AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE NOMINAL ESS AC VOLTAGE: 240 Volts MAXIMUM ESS DC VOLTAGE: 50 Volts SOLAR CAUTION: AUTHORIZED SOLAR PERSONNEL ONLY! AC PHOTOVOLTAIC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS ! [CEC 705.12(B)(2)(3)(B)] LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (MAIN PANEL) STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] [CEC 690.14(C)(2)] ON AC DISCONNECT [CEC 690.5(C)] ON AC DISCONNECT PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOAD LABELS AT SOLAR LOAD CENTER WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 1 2 AUTOMATIC TRANSFER SWITCH SERVICE POINT AND UTILITY METERING 3 4 BATTERY BACKUP RAPID SHUTDOWN SWITCH 1 2 3 4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WA R N I N G L A B E L S EL E C T R I C A L E L E V A T I O N Sheet Scale:N.T.S PV-04 BACK UP PANEL5 SOLAR LOAD CENTER6 ESS BACKUP PANEL. DO NOT ADD LOAD. EQUIPMENT INSIDE MECHANICAL ROOM EQUIPMENT AT MODULES: MICROINVERTERS HUMBOLDT AVE 5 6 7 Date: Drawing: Th e M a d i s o n C l u b Madison Club AP N 7 7 9 - 4 4 0 - 0 1 3 , L O T # 6 1 B 53 3 2 5 H u m b o l d t B o u l e v a r d La Q u i n t a , C A , 9 2 2 5 3 12/14/22 [CEC 690.54] LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE MAX AC OPERATING CURRENT: 110 Amps AC OPERATING AC VOLTAGE: 240 Volts 7 AC DISCONNECT 07/06/2023 Engineering Drawing (mm)Dependence on Irradiance Reliability with Warranty Electrical Data *StandardTest Condi�on(STC):CellTemperature 25°C,Irradiance1000W/m²,AM1.5 *Valueswithouttolerancearetypicalnumbers.Measurementtolerance:±3% Model-STC MaximumRa�ngPower (Pmax) Module Efficiency OpenCircuit Voltage (Voc) MaximumPower Voltage Short Circuit Current (Isc) MaximumPower Current [W] [%] [V] [V] [A] [A] FBM440M7G-BB 20.34 440 41.70 34.60 13.41 12.72 FBM445M7G-BB 20.57 445 41.90 34.80 13.48 12.79 FBM450M7G-BB 20.80 450 42.10 35.00 12.86 13.56 FBM455M7G-BB 21.03  455 42.30 35.20 12.93 13.63 Item Mechanical Load MaximumSystem Voltage Series Fuse Ra�ng Opera�ngTempe rature Specifica�on 5400 Pa 1000V 30 A -40 to85°C 45°C±2°C 0.048%/°C -0.27%/°C -0.33%/°C Temperature Characteris �cs Item NominalModuleOpera�ngTempe rature Tempe rature Coefficient of Isc Tempe rature Coefficient of Voc Tempe rature Coefficient of Pmax Specifica�on Opera�ngCondi�onsMechanical Data Item Dimensions Weight Solar Cell Front Glass Junc�onBox Specifica�on Package Configura�on 31pcsPer Pallet,744pcs per40’HQcontainer 1908 mm(L)1x1134mm(W)1x35mm(D)2 / 75.12Ը (L)1x44.65Ը (W)1x1.38Ը (D)2 24.2kg/53.35lbs 12x10piecesmonocrystallinesolarcellsseriesstrings Whitetoughenedsafetyglass,3.2mmthickness IP 68,3 diodes :Withassemblytoleranceof±2mm[±0.08Ը] :Withassemblytoleranceof±0.8mm[±0.03Ը]2 1 *Nominalmoduleopera�ngtemperature(NMOT):AirmassAM1.5, irradiance800W/m²,temperature20°C,windspeed1m/s. *Reduc�oninefficiencyfrom1000W/m²to200W/m²at25°C:3.5±2%. CellEncapsula�on EVA (Ethylene-Viny-Acetate) Frame Blackanodizedaluminumprofile Cable 1200mm(cablelengthcan becustomized),4mm2 ConnectorsType StaubliMC4 1 year 98.0% 100% 90% 84.8% 0% 0 5 10 15 Years Li n e a r p e r f o r m a n c e w a r r a n t y 20 25 URE Additional value from warranty Standard tiered warranty 25 year 84.8% BackCover Blackcompositefilm C AA 1093 BACK VIEW C-Mounting Hole 8 place 9 35 11 A-A Frame B B 10 11 B-B Frame 1134±2 FRONT VIEW 190 8 ± 2 0 2 4 6 8 10 12 14 051015202530354045 Cu r r e n t [ A ] Voltage [V] 200 W/m2 400 W/m 2 600 W/m2 800 W/m2 1000 W/m2 Temperature 25oC 25 Outputwarranty 25 Product Guarantee Formoreinformation,pleasevisitusat Copyright©2022URECorp.Allrightsreserved 07/06/2023 IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s Srst microgrid-forming, software- deSned microinverters with split-phase power conversion capability to convert DC power to AC power eRciently. The brain of the semiconductor-based microinverter is our proprietary application-speciSc integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or oQ-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redeSne reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • ConSgurable to support a wide range of grid proSles • Meets CA Rule 21 (UL 1741-SA) requirements © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-EN-US-2022-03-17 * Only when installed with IQ System Controller 2, meets UL 1741. ** IQ8M and IQ8A supports split phase, 240V installations only. DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to deSne the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-2-US IQ8A-72-2-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 33 – 45 36 – 45 Operating range V 25 – 58 Min/max start voltage V 30 / 58 Max input DC voltage V 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array conSguration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-2-US IQ8A-72-2-US Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A (L-L) branch circuit4 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak eRciency %97.6 97.6 CEC weighted eRciency %97 97.5 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE CertiScations CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-DS-0003-01-EN-US-2022-03-17 07/06/2023 07/06/2023 07/06/2023 07/06/2023 07/06/2023 07/06/2023 07/06/2023 07/06/2023 07/06/2023 Flashing Red LED Flashes every 30-40 seconds to indicate proper operation Test Button Tests unit’s electronic circuitry, horn and battery function 9V Battery Back Up Provides continuous protection even during power outages Description The Kidde HD135F is a 120VAC Wire In Heat Alarm that responds to temperature rather than smoke. The alarm will sound if temperatures rise above 135˚F. The Kidde HD135F is interconnectable. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices (Smoke, heat, CO, etc) interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. This unit includes a 5-year limited warranty and is UL Listed. Benefits The Kidde HD135F 120VAC wire in heat alarm gives you and your family an early warning to dangerous temperatures of 135˚F or more. This unit can be used as a single station unit or it can be interconnected to up to 24 Kidde devices in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices (Smoke, heat, CO, etc) interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The HD135F includes a tamper resist pin to help deter tampering or theft. Features and Benefits – Interconnects with up to 24 Kidde devices of which 18 can be initiating. – Tests unit’s electronic circuitry, horn and battery function. – Provides continuous protection even during power outages. – Flashes every 30-40 seconds to indicate proper operation. – Alerts user in the event of a low or missing battery. – Makes installation fast and easy. 120VAC Wire In with 9V Battery Back Up Heat Alarm Model HD135F Architectural and Engineering Specifications The heat alarm shall be Kidde Unit HD135F or approved equal. It shall be powered by a 120VAC, 60Hz source along with a 9V battery backup. The temperature operation range shall be between -20F to +100F (-29C and +38C) and the humidity operation range shall be 5% - 95% relative humidity. The heat alarm can be installed on any standard single gang electrical box, up to a 4” octagon junction box. The electrical connection (to the alarm) shall be made with a plug- in connector. A maximum of 24 Kidde devices can be inter- connected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices (Smoke, heat, CO, etc) interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The alarm shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. The unit shall include a piezoelectric horn that is rated at 85dB at 10ft. The unit shall incorporate 2 LED’s. A green LED will be constantly “ON” when AC power is present. A red LED will flash once approximately every 30-40 seconds to indi- cate that the smoke alarm is operating properly and will flash rapidly when the unit is alarming and will remain so until the air temperature is reduced. The unit shall incorporate a test button. The test button shall test all the electronic circuitry, horn, and battery. The unit shall at a minimum meet the requirements of UL217, NFPA72, (chapter 10 & 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwell- ings, Federal Housing Authority (FHA), Housing and Urban Development (HUD). HEAT ALARMS ARE NOT DESIGNED TO PROTECT LIFE SAFETY AGAINST FIRE AND SMOKE. IN CASES WHERE LIFE SAFETY IS AN ISSUE, HEAT ALARMS SHOULD ONLY BE USED AS A SUPPLEMENT TO THE SMOKE ALARM INSTALLATION Installation of Heat Alarm The heat alarm should be installed to comply with all local codes having jurisdiction in your area, Article 760 of the National Electric Code, and NFPA 72. Make certain all alarms are wired to a single, continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maxi- mum of 1000 ft. of wire can be used in the interconnect sys- tem. 120VAC Wire In with 9V Battery Back Up Heat Alarm Model HD135F Technical Specifications Model Number: HD135F UPC: 0-25417-84135-0 Power Source: 120VAC, 60HZ, 9V battery backup Sensor: Heat Audio Alarm: 85dB at 10ft Temperature Range: -20F to +100F (-29C and +38C) Humidity Range: 5%-95% relative humidity (RH) Size: 5” in diameter x 2” depth Weight: .75lbs Interconnects: Up to 24 Kidde devices of which 18 can be initiating devices. LED: Green, AC power present, alarm mode; flashing Red indicates originating unit Warranty: 5 year limited warranty Ordering Information 0-25417-84135-0 HD135F* N/A Individual 4.75 x 2.45 x 5.65 .75lbs N/A N/A N/A HD135F 200 25417 84135 4 Master Pack (6 units) 6.5 x 10.5 x 6.5 4.5lbs 60 5 270lbs *Not for sale by individual unit 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.Kidde.com Distributed by: P/N: KL-HD135 sheet rev. 01-2009 07/06/2023 07/06/2023 07/06/2023