BRES2021-0803 - Title 24 Revision 3CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 1 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribd19x
GENERAL INFORMATION
01
Project Name
Moonbeam lot 61B
02
Run Title
Title 24 Analysis
03
Project Location
The Madison Club Lot 61B
04
City
La Quinta
05
Standards Version
2019
06
Zip code
92253
07
Software Version
EnergyPro 8.3
08
Climate Zone
15
09
Front Orientation (deg/ Cardinal)
45
30
Building Type
Single family
11
Number of Dwelling Units
1
12
Project Scope
NewConstruction
13
Number of Bedrooms
7
14
Addition Cond. Floor Area (ft)
0
15
Number of Stories
1
16
Existing Cond. Floor Area (ft)
n/a
17
Fenestration Average U-factor
0.41
18
Total Cond. Floor Area (ftz)
11756
19
Glazing Percentage (%)
23.64%
20
ADU Bedroom Count
n/a
21
ADU Conditioned Floor Area
n/a
22
Is Natural Gas Available?
I Yes
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
Registration Number:
BRES2021-0803 - 53325 HUMBOLDT BLVDREVISION 3ADDITION
OF LAUNDRY ROOM IN GUEST BED 2 AREA, RELOCATION OF
ALTERNATE FIREPLACES AT GREAT ROOM AND MASTER
CITY OF LA QUINTA
BEDROOM, EXPANSION OF PANTRY WITH NEW SINK,
BUILDING DIVISION
EXPANSION OF REC. ROOM BAR, RECONFIGURATION AT
REVIEWED FOR
HALLWAY,OFFICE AND GOLF SIMULATOR AREAS, REVISED
CODE
FENESTRATION VALUES, AND RELOCATION OF HVAC
COMPLIANCE
07/06/2023 C
CONDENSER UNITS TO SCREENED ROOF TOP ABOVE ENTRY.
DATE ev__C)
NO ADDITIONS TO CONDITIONED SPACE. 2019 CALIFORNIA
BUILDING CODES.
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 2 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x
ENERGY DESIGN RATING
Energy Design Ratings
Compliance Margins
Efficiency' (EDR)
TotalZ (EDR)
Efficiency' (EDR)
TotalZ (EDR)
Standard Design
39.3
20.8
Proposed Design
38.4
20.7
0.9 _T
0.1
RESULT: 3: COMPLIES
1: Efficiency EDR includes improvements to the building envelope and more efficient equipment
2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries
3: Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity: 16.29 kWdc
ENERGY USE SUMMARY
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.78
6.69
-2.91
-77
Space Cooling
81.83
76.73
5.1
6.2
IAQ Ventilation
2.74
2.74
0
0
Water Heating
2
1.69
0.31
15.5
Self Utilization/Flexibility Credit
n/a
0
0
n/a
Compliance Energy Total
90.35
87.85
2.5
2.8
REQUIRED PV SYSTEMS - SIMPLIFIED
01
02
03
04
05
06
07
08
09
10
11
12
DC System Size
Azimuth
Tilt
Array Angle
Tilt: (x in
Inverter Eff.
Annual
(kWdc)
Exception
Module Type
Array Type
Power Electronics
CFI
(deg)
Input
(deg)
12)
N
Solar Access
N
15.7
NA
Standard
Fixed
none
false
180
Degre
5
1.05
96
100
es
Registration Number: Registration Date/Time: HERS Provider:
223-P010062858A-000-000-0000000-0000 2023-05-30 13:27:20 CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 3 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Insulation below roof deck
• Window overhangs and/or fins
HERS FEATURE SUMMARY
IThe following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional I
detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level Verifications:
• Quality insulation installation (QII)
• Indoor air quality ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified heat pump rated heating capacity HVAC Distribution System Verifications: CaICERTS, Inc.
• Duct leakage testing H E R S P R O V I D E R
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
2
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Moonbeam lot 61B
11756
1
7
9
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft2)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
bedroom 1
Conditioned
HVACbed 1 3T1
867
9
DHW Sys 1
N/A
Registration Number:
223-P010062858A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2019 Residential Compliance
Registration Date/Time:
2023-05-30 13:27:20
Report Version: 2019.2.000
Schema Version: rev 20200901
HERS Provider:
CaICERTS inc.
Report Generated: 2023-05-30 08:54:02
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 4 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area (ft)
Avg. Ceiling Height
Water Heating System 1
Water Heating System 2
guest 1
Conditioned
HVACgst 1 5T2
1341
9
DHW Sys 1
N/A
Bunk Room
Conditioned
HVACbunk5t 3t3
1548
9
DHW Sys 1
N/A
Main bedroom 1
Conditioned
HVACmainbed 5T4
1391
9
DHW Sys 1
N/A
great
Conditioned
HVACgreat 2-4T5
2259
9
DHW Sys 1
N/A
office bed 3
Conditioned
HVACoffice5 T6
1555
9
DHW Sys 1
N/A
bedroom 2
Conditioned
HVACbed 2 4TON7
1173
9
DHW Sys 1
N/A
storage
Conditioned
HVAC storage8
82
10
DHW Sys 1
N/A
Garage
Conditioned
HVAC garage9
1540
10
DHW Sys 1
N/A
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
NE Wall
bedroom 1
R-23 Wall (W.23.2x6.16)
45
Front
380
80
90
SE Wall
bedroom 1
R-21
135
Left
420
102
90
SW Wall
bedroom 1
R-21
225
Back
380
75
90
NW Wall
bedroom 1
R-21
315
Right
420
0
90
NE Wall 2
guest 1
R-21
45
Front
624
160
90
SE Wall 2
guest 1
R-21
135
Left
528
9
90
SW Wall 2
guest 1
R-21
225
Back
172
75
90
NW Wall 2
guest 1
R-21
315
Right
624
102
90
NE Wall 3
Bunk Room
R-21
45
Front
560
300
90
SE Wall 3
Bunk Room
R-21
135
Left
420
81
90
SW Wall 3
Bunk Room
R-21
225
Back
172
0
90
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 5 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
NW Wall 3
Bunk Room
R-21
315
Right
200
130
90
NE Wall 4
Main bedroom 1
R-21
45
Front
72
0
90
SE Wall 4
Main bedroom 1
R-21
135
Left
784
152.5
90
SW Wall 4
Main bedroom 1
R-21
225
Back
504
180
90
NW Wall 4
Main bedroom 1
R-21
315
Right
172
0
90
NE Wall 5
great
R-21
45
Front
72
0
90
SE Wall 5
great
R-21
135
Left
72
0
90
SW Wall 5
great
R-21
225
Back
720
615
90
NW Wall 5
great
R-21
315
Right
180
60
90
NE Wall 6
office bed 3
R-21
45
Front
512
0
90
SE Wall 6
office bed 3
R-21
135
Left
384
180
90
SW Wall 6
office bed 3
R-21
225
Back
172
7.5
90
NW Wall 6
office bed 3
R-21
315
Right
384
117.5
90
NE Wall 7
bedroom 2
R-21
45
Front
72
0
90
SE Wall 7
bedroom 2
R-21
135
Left
392
0
90
SW Wall 7
bedroom 2
R-21
225
Back
392
180
90
NW Wall 7
bedroom 2
R-21
315
Right
784
88.5
90
NE Wall 8
storage
R-21
45
Front
10
0
90
SE Wall 8
storage
R-21
135
Left
25
0
90
145d Wall
storage
R-21
145
n/a
90
0
90
SW Wall 8
storage
R-21
225
Back
60
0
90
NW Wall 8
storage
R-21
315
Right
110
0
90
SE Wall 9
Garage
R-21
135
Left
640
384
90
SW Wall 9
Garage
R-21
225
Back
360
84
90
NW Wall
Garage
R-21
315
Right
140
0
90
Interior Surface
bedroom 1
R-0 Interior Wall
n/a
n/a
467
0
n/a
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 6 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window and Door
Area (ft2)
Tilt (deg)
Interior Surface 2
guest 1
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 3
Bunk Room
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 4
Main bedroom 1
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 5
great
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 6
office bed 3
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 7
bedroom 2
R-0 Interior Wall
n/a
n/a
467
0
n/a
Interior Surface 8
Garage»bedroom 2
R-0 Interior Wall
n/a
n/a
320
0
n/a
Roofbedl
bedroom 1
R-44
n/a
n/a
867
n/a
n/a
Roofgstl
guest 1
R-44
n/a
n/a
1341
n/a
n/a
Roofbunk
Bunk Room
R-44
n/a
n/a
1548
n/a
n/a
Roofbedmain
Main bedroom 1
R-44
n/a
n/a
1391
n/a
n/a
Roofgrt
great
R-44
n/a
n/a
2259
n/a
n/a
Roofoffice
office bed 3
R-44
n/a
n/a
1555
n/a
n/a
Roofbed2
bedroom 2
R-44
n/a
n/a
1173
n/a
n/a
Roofgrt 2
storage
R-44
n/a
n/a
82.5
n/a
n/a
Roofgrt 3
Garage
R-44
n/a
n/a
1540
n/a
n/:a::::::l
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic bedroom 1
Attic Roofbedroom 1
Unventilated
3
0.1
0.85
No
No
Attic guest 1
Attic Roofgueat 1
Unventilated
3
0.1
0.85
No
No
Attic Bunk Room
Attic RoofBunk Room
Unventilated
3
0.1
0.85
No
No
Attic Main bedroom 1
Attic RoofMain
bedroom 1
Unventilated
3
0.1
0.85
No
No
Attic great
Attic Roofgreat
Unventilated
3
0.1
0.85
No
No
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 7 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise (x in 12)
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic office bed 3
Attic Roofoffice bed 3
Unventilated
3
0.1
0.85
No
No
Attic bedroom 2
Attic Roofbedroom 2
Unventilated
3
0.1
0.85
No
No
Attic storage
Attic Roofstorage
Unventilated
3
0.1
0.85
No
No
Attic Garage
Attic RoofGarage
Unventilated
3
0.1
0.85
No
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MUIt.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
GA
Window
NE Wall
Front
45
8
10
1
80
0.4
NFRC
0.23
NFRC
Bug Screen
G14
Window
SE Wall
Left
135
1
27
0.59
NFRC
0.63
NFRC
Bug Screen
G12
Window
SE Wall
Left
135
1
75
0.4
NFRC
0.23
NFRC
Bug Screen
G13
Window
SW Wall
Back
225
1
75
0.4
NFRC
0.23
NFRC
Bug Screen
GB
Window
NE Wall 2
Front
45
8
10
1
80
0.4
NFRC
0.23
NFRC
Bug Screen
GD
Window
NE Wall 2
Front
45
8
10
1
80
0.4
NFRC
0.23
NFRC
Bug Screen
GC
Window
SE Wall 2
Left
135
1
9
0.51
NFRC
0.29
NFRC
Bug Screen
G4
Window
SW Wall 2
Back
225
7.5
10
1
75
0.4
NFRC
0.23
NFRC
Bug Screen
G3
Window
NW Wall 2
Right
315
7.5
10
1
75
0.4
NFRC
0.23
NFRC
Bug Screen
G1
Window
NW Wall 2
Right
315
1
27
0.59
NFRC
0.63
NFRC
Bug Screen
18
Window
NE Wall 3
Front
45
30
10
1
300
0.4
NFRC
0.23
NFRC
Bug Screen
B
Window
SE Wall 3
Left
135
3
3
1
9
0.51
NFRC
0.29
NFRC
Bug Screen
C
Window
SE Wall 3
Left
135
4
3
1
12
0.51
NFRC
0.29
NFRC
Bug Screen
25
Window
SE Wall 3
Left
135
6
10
1
60
0.3
NFRC
0.17
NFRC
Bug Screen
19
Window
NW Wall 3
Right
315
13
10
1
130
0.4
NFRC
0.23
NFRC
Bug Screen
D
Window
SE Wall 4
Left
135
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
E
Window
SE Wall 4
Left
135
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 8 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Name
Type
Surface
Orientation
Azimuth
Width
(ft)
Height
(ft)
MUlt.
Area
z
(ft)
U-factor
U-factor
Source
SHGC
SHGC
Sourc
a
Exterior
Shading
F
Window
SE Wall 4
Left
135
1
35
0.35
NFRC
0.24
NFRC
Bug Screen
G
Window
SE Wall 4
Left
135
1
18
0.35
NFRC
0.24
NFRC
Bug Screen
H
Window
SE Wall 4
Left
135
1
35
0.35
NFRC
0.24
NFRC
Bug Screen
I
Window
SE Wall 4
Left
135
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
J
Window
SE Wall 4
Left
135
1
21
0.51
NFRC
0.29
NFRC
Bug Screen
K
Window
SE Wall 4
Left
135
1
21
0.51
NFRC
0.29
NFRC
Bug Screen
34
Window
SW Wall 4
Back
225
15
12
1
180
0.4
NFRC
0.23
NFRC
Bug Screen
42
Window
SW Wall 5
Back
225
41
15
1
615
0.4
NFRC
0.23
NFRC
Bug Screen
15
Window
NW Wall 5
Right
315
6
10
1
60
0.3
NFRC
0.17
NFRC
Bug Screen
5
Window
SE Wall 6
Left
135
9
10
1
90
0.4
NFRC
0.23
NFRC
Bug Screen
16
Window
SE Wall 6
Left
135
9
10
1
90
0.4
NFRC
0.23
NFRC
Bug Screen
R
Window
SW Wall 6
Back
225
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
13
Window
NW Wall 6
Right
315
10
10
1
100
0.4
NFRC
0.23
NFRC
Bug Screen
S
Window
NW Wall 6
Right
315
3.5
5
1
17.5
0.51
NFRC
0.29
NFRC
Bug Screen
35
Window
SW Wall 7
Back
225
1
180
0.4
NFRC
0.23
NFRC
Bug Screen
L
Window
NW Wall 7
Right
315
1
21
0.51
NFRC
0.29
NFRC
Bug Screen
M
Window
NW Wall 7
Right
315
1
21
0.51
NFRC
0.29
NFRC
Bug Screen
N
Window
NW Wall 7
Right
315
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
O
Window
NW Wall 7
Right
315
1
24
0.35
NFRC
0.24
NFRC
Bug Screen
P
Window
NW Wall 7
Right
315
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
Q
Window
NW Wall 7
Right
315
1
7.5
0.51
NFRC
0.29
NFRC
Bug Screen
T
Window
SW Wall 9
Back
225
1
84
1 0.51
1 NFRC
0.29
NFRC
Bug Screen
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 9 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Garage Door
SE Wall 9
96
0.0788043
Garage Door 2
SE Wall 9
144
0.0788043
Garage Door 3
SE Wall 9
144
0.0788043
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
GA
10
0.1
10
10
0
0
0
0
0
0
0
0
0
GB
10
0.1
10
10
0
0
0
0
0
0
0
0
0
GD
10
0.1
10
10
0
0
0
0
0
0
0
0
0
G4
8
0.1
8
8
0
0
0
0
0
0
0
0
0
G3
10
0.1
10
10
0
0
0
0
0
0
0
0
0
18
10
0.1
10
10
0
0
0
0
0
0
0
0
0
B
8
0.1
8
8
0
0
0
0
0
0
0
0
0
C
8
0.1
8
8
0
0
0
0
0
0
0
0
0
25
4
0.1
4
4
0
0
0
0
0
0
0
0
0
19
10
0.1
10
10
0
0
0
0
0
0
0
0
0
34
10
0.1
10
10
0
0
0
0
0
0
0
0
0
42
18
0.1
18
18
0
0
0
0
0
0
0
0
0
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 10 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Window
Overhang
Left Fin
Right Fin
Depth
Dist Up
Left Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
15
10
0.1
10
10
0
0
0
0
0
0
0
0
0
5
10
0.1
10
10
0
0
0
0
0
0
0
0
0
16
10
0.1
10
10
0
0
0
0
0
0
0
0
0
13
10
0.1
10
10
0
0
0
0
0
0
0
0
0
S
10
0.1
10
10
0
0
0
0
0
0
0
0
0
SLAB FLOORS
01
02
03
04
05
06
07
08
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value
and Depth
Edge Insul. R-value
and Depth
Carpeted Fraction
Heated
Slab -on -Grade
bedroom 1
867
110
none
0
80%
No
Slab -on -Grade 2
guest 1
1341
180
none
0
80%
No
Slab -on -Grade 3
Bunk Room
1548
80
none
0
80%
No
Slab -on -Grade 4
Main bedroom 1
1391
125
none
0
80%
No
Slab -on -Grade 5
great
2259
192
none
0
80%
No
Slab -on -Grade 6
office bed 3
1555
160
none
0
80%
No
Slab -on -Grade 7
bedroom 2
1173
145
none
0
80%
No
Slab -on -Grade 8
storage
82.5
29
none
0
80%
No
Slab -on -Grade 9
Garage
1540
112
none
0
80%
No
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 11 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Inside Finish: Gypsum Board
R-23 Wall (W.23.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-23
None / None
0.066
Cavity / Frame: R-23 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-21
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. 0. C.
R-21
None / None
0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. 0. C.
R-0
None / None
0.277
Cavity / Frame: no insul. / 2x4
Other Side Finish: Gypsum Board
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
�s
Roof Deck: Wood
Attic Roofbedroom 1
Attic Roofs
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
f
F
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofguest 1
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofBunk Room
Attic Roofs
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Attic RoofMain
Wood Framed
Roof Deck: Wood
bedroom 1
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 12 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
Interior / Exterior
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
Continuous
U-factor
Assembly Layers
R-value
R-value
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofgreat
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofoffice bed 3
Attic Roofs
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofbedroom 2
Attic Roofs
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Ceiling
s »
Cavity / Frame: R-13.0 / 2x4
_
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic Roofstorage
Attic Roofs
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Ceiling
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
Roofing: Light Roof (Asphalt Shingle)
Wood Framed
Roof Deck: Wood
Attic RoofGarage
Attic Roofs
Ceiling
2x4 @ 24 in. 0. C.
R-44
None / None
0.022
Siding/sheathing/decking
Cavity / Frame: R-13.0 / 2x4
Under Roof Joists: R-31.0 insul.
R-44
Ceilings (below
Wood Framed
2x4 @ 16 in. 0. C.
R-0
None /None
0.472
Cavity / Frame: no insul. / 2x4
attic)
Ceiling
Inside Finish: Gypsum Board
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 13 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
High R-value Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
Name
System Type
Distribution Type
Water Heater Name (#)
Solar Heating System
Compact Distribution
HERS Verification
DHW Sys 1
Domestic Hot Water
(DHW)
Standard Distribution
System
DHW Heater 1 (2)
n/a
None
n/a
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Tank
Energy
Tank
Standby Loss
Name
Element
Tank Type
# of
Vol.
Factor or
Input Rating
Insulation
or Recovery
1st Hr. Rating
NEEA Heat Pump
Tank Location or
Type
Units
(gal)
Efficiency
or Pilot
R-value
Eff
or Flow Rate
Brand or Model
Ambient Condition
(Int/Ext)
DHW Heater 1
Gas
Consumer
2
0
0.99-UEF
<= 200
0
n/a
n/a
n/a
n/a
Instantaneous
kBtu/hr
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Type Compact Distribution
Recirculation Control
Central DHW
Distribution
Shower Drain Water
Heat Recovery
DHW Sys 1 - 1/2
Not Required
Not Required
Not Required
None
Not Required
Not Required
Not Required
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 14 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
11
Heating Unit
Cooling Unit
Distribution
Required
Verified
Heating
Cooling
Name
System Type
Fan Name
Thermostat
Status
Existing
Equipment
Equipment
Name
Name
Name
Type
Condition
Count
Count
HVACbed 1 3T1
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 1
Air
Distribution
Setback
New
NA
1
1
System 1
System 1
System 1
HVACgst 1 5T2
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 2
Air
Distribution
Setback
New
NA
1
1
System 2
System 2
System 2
HVACbunk5t 3t3
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 3
Air
Distribution
Setback
New
NA
1
1
System 3
System 3
System 3
HVACmainbed 5T4
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 4
Air
Distribution
Setback
New
NA
1
1
System 4
System 4
System 4
HVACgreat 2-4T5
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 5
Air
Distribution
Setback
New
NA
2
2
System 5
System 5
System 5
HVACoffice5 T6
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 6
Air
Distribution
Setback
New
NA
1
1
System 6
System 6
System 6
HVACbed 2 4TON7
Heat pump heating cooling
Heat Pump
Heat Pump
HVAC Fan 7
Air
Distribution
Setback
New
NA
1
1
System 7
System 7
System 7
HVAC storage8
Heat pump heating cooling
Heat Pump
Heat PumpSystem
n/a
n/a
Setback
New
NA
1
1
8
System 8
HVAC garage9
Heat pump heating cooling
Heat Pump
Heat Pump
n/a
n/a
Setback
New
NA
1
1
System 9
System 9
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 15 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x
01
02
03
04
05
06
07
08
09
10
11
HVAC - HEAT PUMPS
Heating
Cooling
Name
System Type
Number of Units
Zonally
Controlled
Compressor
Type
HERS Verification
HSPF/HSPF2
EER/EER2/C
/COP
Cap 47
Cap 17
SEER/SEER2
EER
Heat Pump System 1
Central split HP
1
8
35500
21300
16
13
Not Zonal
Single
Heat Pump System
Speed
1-hers-htpump
Heat Pump System 2
Central split HP
1
8
55500
33360
16
13
Not Zonal
Single
Heat Pump System
Speed
2-hers-htpump
Heat Pump System 3
Central split HP
1
8
55500
33300
16
13
Not Zonal
Single
Heat Pump System
Speed
3-hers-htpump
Heat Pump System 4
Central split HP
1
8
55500
33360
16
13
Not Zonal
Single
Heat Pump System
Speed
4-hers-htpump
Heat Pump System 5
Central split HP
2
8
45500
27300
16
13
Not Zonal
Single
Heat Pump System
Speed
5-hers-htpump
Heat Pump System 6
Central split HP
1
8
55500
33360
16
13
Not Zonal
Single
Heat Pump System
Speed
6-hers-htpump
Heat Pump System 7
Central split HP
1
8
45500
27300
16
13
Not Zonal
Single
Heat Pump System
Speed
7-hers-htpump
Heat Pump System 8
Ductless
1
10
14000
9100
18
12.1
Not Zonal
Single
Heat Pump System
MiniSplit HP
Speed
8-hers-htpump
Heat Pump System 9
Ductless
1
9.5
39000
25350
18
12.5
Not Zonal
Single
Heat Pump System
MiniSplit HP
Speed
9-hers-htpump
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 16 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
HVAC HEAT PUMPS - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Verified HSPF
Verified Heating
Verified Heating
Charge
Cap 47
Cap 17
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
1-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
2-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
3-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
4-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
5-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
6-hers-htpump
Heat Pump System
Required
350
Required
Required
Yes
No
Yes
Yes
7-hers-htpump
Heat Pump System
Not Required
0
Not Required
Not Required
Yes
No
Yes
Yes
8-hers-htpump
Heat Pump System
Not Required
0
Not Required
Not Required
Yes
No
Yes
Yes
9-hers-htpump
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
30
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Supply
Return
Supply
Return
Supply
Return
BypasDucts
Duct Leakage
HERS
Verification
Air
Air Distribution
No
Sealed and
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 1
Tested
System
Duct
1-hers-dist
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 17 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
30
11
12
Duct Ins. R-value
Duct Location
Surface Area
Name
Type
Design Type
Supply
Return
Supply
Return
Supply
Return
BypasDucts
Duct Leakage
HERS
Verification
Air
Air Distribution
No
Sealed and
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 2
Tested
System
Duct
2-hers-dist
Air
Air Distribution
No
Sealed and
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 3
Tested
System
Duct
3-hers-dist
Air
Air Distribution
NO
Sealed and
Distribution
Unconditioned attic
Non Verified
R-8
R 8
Attic
Attic
n/a
n/a
Bypass
System 4
Tested
System
Duct
4-hers-dist
Air
Air Distribution
NO
Sealed and
Distribution
Unconditioned attic
Non -Verified
R-8
R-8
Attic
Attic
n/a
n/a
Bypass
System 5
Tested
System
Duct
5-hers-dist
Air
Air Distribution
NO
Sealed and
Distribution
Unconditioned attic
Non Verified
R-8
R 8
Attic
Attic
n/a
n/a
Bypass
System 6
Tested
System
Duct
6-hers-dist
Air
Air Distribution
NO
Sealed and
Distribution
Unconditioned attic
Non Verified
R 8
R 8
Attic
Attic
n/a
n/a
Bypass
System 7
Tested
System
Duct
7-hers-dist
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 18 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
09
Low Leakage
Name
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried Ducts
Deeply Buried
Low -leakage Air
Ducts Entirely in
Verification
Target (%)
Location
Design
Ducts
Handler
Conditioned
Space
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 1-hers-dist
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 2-hers-dist
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 3-hers-dist
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 4-hers-dirt
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 5-hers-dist
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 6-hers-dist
Air Distribution
Yes
5.0
Not Required
Not Required
Not Required
Credit not taken
Not Required
No
System 7-hers-dist
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 1
HVAC Fan
0.35
HVAC Fan 1-hers-fan
HVAC Fan 2
HVAC Fan
0.35
HVAC Fan 2-hers-fan
HVAC Fan 3
HVAC Fan
0.35
HVAC Fan 3-hers-fan
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 19 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-2l.ribdl9x
HVAC - FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
Name
HVAC Fan 4
HVAC Fan
0.35
HVAC Fan 4-hers-fan
HVAC Fan 5
HVAC Fan
0.35
HVAC Fan 5-hers-fan
HVAC Fan 6
HVAC Fan
0.35
HVAC Fan 6-hers-fan
HVAC Fan 7
HVAC Fan
0.35
HVAC Fan 7-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficacy (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.35
HVAC Fan 2-hers-fan
Required
0.35
HVAC Fan 3-hers-fan
Required
0.35
HVAC Fan 4-hers-fan
Required
0.35
HVAC Fan 5-hers-fan
Required
0.35
HVAC Fan 6-hers-fan
Required
0.35
HVAC Fan 7-hers-fan
Required
0.35
IAQ (INDOOR AIR QUALITY) FANS
01
02
03
04
05
06
07
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness - SIRE
IAQ RecoveryHERS
Effectiveness - ASRE
Verification
SFam IAQVentRpt
392
0.35
Exhaust
n/a
n/a
Yes
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Moonbeam lot 61B
Calculation Description: Title 24 Analysis
CF1R-PRF-01E
Calculation Date/Time: 2023-05-30T08:52:08-07:00 (Page 20 of 20)
Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribd19x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
;�_5elozr
Company:
Signature Date:
Scott Design and Title 24, Inc.
2023-05-30 13:27:20
Address:
CEA/ HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
;c V-5cezr
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2023-05-30 13:27:20
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number:
223-P010062858A-000-000-0000000-0000
Registration Date/Time:
2023-05-30 13:27:20
HERS Provider:
' 'fc
0_
Easy to Verify
at CaICERTS.com
CaICERTS inc.
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2023-05-30 08:54:02