Loading...
BRES2021-0803 - Title 24 Revision 2CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 1 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x GENERAL INFORMATION 01 Project Name Moonbeam lot 61B 02 Run Title Title 24 Analysis 03 Project Location The Madison Club Lot 61B 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.3 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 45 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 7 14 Addition Cond. Floor Area (ft) 0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2) 11833.5 19 Glazing Percentage (%) 23.48% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available? Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 02/27/2023 BY"D C Registration Number: 222-P010229539A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2019 Residential Compliance BRES2021-0803 - 53325 HUMBOLDT BLVD ADDITION OF MECHANICAL EQUIPMENT FOR CONDITIONING OF GARAGE AND STORAGE AREAS. 2019 CALIFORNIA BUILDING CODES. Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 Report Version: 2019.2.000 Schema Version: rev 20200901 CaICERTS inc. Report Generated: 2022-11-28 15:12:02 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 2 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x ENERGY DESIGN RATING Energy Design Ratings Compliance Margins Efficiency' (EDR) Total' (EDR) Efficiency' (EDR) Total' (EDR) Standard Design 39.3 20.8 Proposed Design 36.9 20.8 2.4 -T 0 RESULT: 3: COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 16.35 kWdc ENERGY USE SUMMARY Energy Use (kTDV/ftz-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.77 5.63 -1.86 -49.3 Space Cooling 81.65 73.84 7.81 9.6 IAQ Ventilation 2.74 2.74 0 0 Water Heating 1.99 1.68 0.31 15.6 Self Utilization/Flexibility Credit n/a 0 0 n/a Compliance Energy Total 90.15 83.89 6.26 6.9 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Tilt: (x in Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) 12) N Solar Access N 14.9 NA Standard Fixed none false 180 Degre 0 0 96 100 es Registration Number: Registration Date/Time: HERS Provider: 222-P010229539A-000-000-0000000-0000 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 3 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ceiling has high level of insulation • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Indoor air quality ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified heat pump rated heating capacity CaICERTS, In(... HVAC Distribution System Verifications: H E R S P R O V I D E R • Duct leakage testing Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftz) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Moonbeam lot 61B 11833.5 1 7 9 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 bedroom 1 Conditioned HVACbed 1 3T1 867 9 DHW Sys 1 N/A Registration Number: Registration Date/Time: HERS Provider: 222-P010229539A-000-000-0000000-0000 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 4 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 guest 1 Conditioned HVACgst 1 5T2 1341 9 DHW Sys 1 N/A Bunk Room Conditioned HVACbunk5t 30 1598 9 DHW Sys 1 N/A Main bedroom 1 Conditioned HVACmainbed 5T4 1391 9 DHW Sys 1 N/A great Conditioned HVACgreat 2-4T5 2264 9 DHW Sys 1 N/A office bed 3 Conditioned HVACoffice5 T6 1560 9 DHW Sys 1 N/A bedroom 2 Conditioned HVACbed 2 4TON7 1123 9 DHW Sys 1 N/A storage Conditioned HVAC storage8 82.5 10 DHW Sys 1 N/A Garage Conditioned HVAC garage9 1607 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftz) Window and Door Area (ft2) Tilt (deg) NE Wall bedroom 1 R-23 Wall (W.23.2x6.16) 45 Front 380 80 90 SE Wall bedroom 1 R-21 135 Left 420 102 90 SW Wall bedroom 1 R-21 225 Back 380 75 90 NW Wall bedroom 1 R-21 315 Right 420 0 90 NE Wall 2 guest 1 R-21 45 Front 624 160 90 SE Wall 2 guest 1 R-21 135 Left 528 9 90 SW Wall 2 guest 1 R-21 225 Back 172 75 90 NW Wall 2 guest 1 R-21 315 Right 624 102 90 NE Wall 3 Bunk Room R-21 45 Front 560 300 90 SE Wall 3 Bunk Room R-21 135 Left 420 81 90 SW Wall 3 Bunk Room R-21 225 Back 172 0 90 Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 5 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) NW Wall 3 Bunk Room R-21 315 Right 200 130 90 NE Wall Main bedroom 1 R-21 45 Front 72 0 90 SE Wall 4 Main bedroom 1 R-21 135 Left 784 152.5 90 SW Wall Main bedroom 1 R-21 225 Back 504 180 90 NW Wall 4 Main bedroom 1 R-21 315 Right 172 0 90 NE Wall 5 great R-21 45 Front 72 0 90 SE Wall 5 great R-21 135 Left 72 0 90 SW Wall 5 great R-21 225 Back 720 615 90 NW Wall 5 great R-21 315 Right 180 60 90 NE Wall 6 office bed 3 R-21 45 Front 512 0 90 SE Wall 6 office bed 3 R-21 135 Left 384 180 90 SW Wall 6 office bed 3 R-21 225 Back 172 7.5 90 NW Wall 6 office bed 3 R-21 315 Right 384 117.5 90 NE Wall 7 bedroom 2 R-21 45 Front 72 0 90 SE Wall 7 bedroom 2 R-21 135 Left 392 0 90 SW Wall 7 bedroom 2 R-21 225 Back 392 180 90 NW Wall 7 bedroom 2 R-21 315 Right 784 88.5 90 NE Wall 8 storage R-21 45 Front 10 0 90 SE Wall 8 storage R-21 135 Left 25 0 90 145d Wall storage R-21 145 n/a 90 0 90 SW Wall 8 storage R-21 225 Back 60 0 90 NW Wall 8 storage R-21 315 Right 110 0 90 SE Wall 9 Garage R-21 135 Left 640 384 90 SW Wall 9 Garage R-21 225 Back 360 84 90 NW Wall 9 Garage R-21 315 Right 140 0 90 Interior Surface bedroom 1 R-0 Interior Wall n/a n/a 467 0 n/a Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 6 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window and Door Area (ft2) Tilt (deg) Interior Surface 2 guest 1 R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 3 Bunk Room R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 4 Main bedroom 1 R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 5 great R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 6 office bed 3 R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 7 bedroom 2 R-0 Interior Wall n/a n/a 467 0 n/a Interior Surface 8 Garage»bedroom 2 R-0 Interior Wall n/a n/a 320 0 n/a Roofbedl bedroom 1 R-44 n/a n/a 867 n/a n/a Roofgstl guest 1 R-44 n/a n/a 1341 n/a n/a Roofbunk Bunk Room R-44 n/a n/a 1598 n/a n/a Roofbedmain Main bedroom 1 R-44 n/a n/a 1391 n/a n/a Roofgrt great R-44 n/a n/a 2264 n/a n/a Roofoffice office bed 3 R-44 n/a n/a 1560 n/a n/a Roofbed2 bedroom 2 R-44 n/a n/a 1123 n/a n/a Roofgrt 2 storage R-44 n/a n/a 82.5 n/a n/a Roofgrt 3 Garage R-44 n/a n/a 1617 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic bedroom 1 Attic Roofbedroom 1 Unventilated 3 0.1 0.85 No No Attic guest 1 Attic Roofgueat 1 Unventilated 3 0.1 0.85 No No Attic Bunk Room Attic RoofBunk Room Unventilated 3 0.1 0.85 No No Attic Main bedroom 1 Attic RoofMain bedroom 1 Unventilated 3 0.1 0.85 No No Attic great Attic Roofgreat Unventilated 3 0.1 0.85 No No Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 7 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic office bed 3 Attic Roofoffice bed 3 Unventilated 3 0.1 0.85 No No Attic bedroom 2 Attic Roofbedroom 2 Unventilated 3 0.1 0.85 No No Attic storage Attic Roofstorage Unventilated 3 0.1 0.85 No No Attic Garage Attic RoofGarage Unventilated 3 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft2) U-factor U-factor Source SHGC SHGC Sourc a Exterior Shading GA Window NE Wall Front 45 8 10 1 80 0.3 NFRC 0.2 NFRC Bug Screen G14 Window SE Wall Left 135 1 27 0.3 NFRC 0.2 NFRC Bug Screen G12 Window SE Wall Left 135 1 75 0.3 NFRC 0.2 NFRC Bug Screen Window SW Wall Back 225 1 75 0.3 NFRC 0.2 NFRC Bug Screen GB Window NE Wall 2 Front 45 8 10 1 80 0.3 NFRC 0.2 NFRC Bug Screen GD Window NE Wall 2 Front 45 8 10 1 80 0.3 NFRC 0.2 NFRC Bug Screen GC Window SE Wall 2 Left 135 1 9 0.3 NFRC 0.2 NFRC Bug Screen G4 Window SW Wall 2 Back 225 7.5 10 1 75 0.3 NFRC 0.2 NFRC Bug Screen G3 Window NW Wall 2 Right 315 7.5 10 1 75 0.3 NFRC 0.2 NFRC Bug Screen G1 Window NW Wall 2 Right 315 1 27 0.3 NFRC 0.2 NFRC Bug Screen 18 Window NE Wall 3 Front 45 30 10 1 300 0.3 NFRC 0.2 NFRC Bug Screen B Window SE Wall 3 Left 135 3 3 1 9 0.3 NFRC 0.2 NFRC Bug Screen C Window SE Wall 3 Left 135 4 3 1 12 0.3 NFRC 0.2 NFRC Bug Screen 25 Window SE Wall 3 Left 135 6 10 1 60 0.3 NFRC 0.2 NFRC Bug Screen 19 Window NW Wall 3 Right 315 13 10 1 130 0.3 NFRC 0.2 NFRC Bug Screen D Window SE Wall 4 Left 135 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen E Window SE Wall 4 Left 135 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 8 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ftz) U-factor U-factor Source SHGC SHGC Sourc e Exterior Shading F Window SE Wall 4 Left 135 1 35 0.3 NFRC 0.2 NFRC Bug Screen G Window SE Wall 4 Left 135 1 18 0.3 NFRC 0.2 NFRC Bug Screen H Window SE Wall 4 Left 135 1 35 0.3 NFRC 0.2 NFRC Bug Screen I Window SE Wall 4 Left 135 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen J Window SE Wall 4 Left 135 1 21 0.3 NFRC 0.2 NFRC Bug Screen K Window SE Wall 4 Left 135 1 21 0.3 NFRC 0.2 NFRC Bug Screen 34 Window SW Wall 4 Back 225 15 12 1 180 0.3 NFRC 0.2 NFRC Bug Screen 42 Window SW Wall 5 Back 225 41 15 1 615 0.3 NFRC 0.2 NFRC Bug Screen 15 Window NW Wall 5 Right 315 6 10 1 60 0.3 NFRC 0.2 NFRC Bug Screen 5 Window SE Wall 6 Left 135 9 10 1 90 0.3 NFRC 0.2 NFRC Bug Screen 16 Window SE Wall 6 Left 135 9 10 1 90 0.3 NFRC 0.2 NFRC Bug Screen R Window SW Wall 6 Back 225 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen 13 Window NW Wall 6 Right 315 10 10 1 100 0.3 NFRC 0.2 NFRC Bug Screen S Window NW Wall 6 Right 315 3.5 5 1 17.5 0.3 NFRC 0.2 NFRC Bug Screen 35 Window SW Wall 7 Back 225 1 180 0.3 NFRC 0.2 NFRC Bug Screen L Window NW Wall 7 Right 315 1 21 0.3 NFRC 0.2 NFRC Bug Screen M Window NW Wall 7 Right 315 1 21 0.3 NFRC 0.2 NFRC Bug Screen N Window NW Wall 7 Right 315 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen O Window NW Wall 7 Right 315 1 24 0.3 NFRC 0.2 NFRC Bug Screen P Window NW Wall 7 Right 315 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen Q Window NW Wall 7 Right 315 1 7.5 0.3 NFRC 0.2 NFRC Bug Screen T Window SW Wall 9 Back 225 1 84 0.3 NFRC 0.2 NFRC Bug Screen Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 9 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor Garage Door SE Wall 9 96 0.0788043 Garage Door 2 SE Wall 9 144 0.0788043 Garage Door 3 SE Wall 9 144 0.0788043 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up GA 10 0.1 10 10 0 0 0 0 0 0 0 0 0 GB 10 0.1 10 10 0 0 0 0 0 0 0 0 0 GD 10 0.1 10 10 0 0 0 0 0 0 0 0 0 G4 8 0.1 8 8 0 0 0 0 0 0 0 0 0 G3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 18 10 0.1 10 10 0 0 0 0 0 0 0 0 0 B 8 0.1 8 8 0 0 0 0 0 0 0 0 0 C 8 0.1 8 8 0 0 0 0 0 0 0 0 0 25 4 0.1 4 4 0 0 0 0 0 0 0 0 0 19 10 0.1 10 10 0 0 0 0 0 0 0 0 0 34 10 0.1 10 10 0 0 0 0 0 0 0 0 0 42 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 10 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 15 10 0.1 10 10 0 0 0 0 0 0 0 0 0 5 10 0.1 10 10 0 0 0 0 0 0 0 0 0 16 10 0.1 10 10 0 0 0 0 0 0 0 0 0 13 10 0.1 10 10 0 0 0 0 0 0 0 0 0 S 10 0.1 10 10 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab -on -Grade bedroom 1 867 110 none 0 80% No Slab -on -Grade 2 guest 1 1341 180 none 0 80% No Slab -on -Grade 3 Bunk Room 1598 80 none 0 80% No Slab -on -Grade 4 Main bedroom 1 1391 125 none 0 80% No Slab -on -Grade 5 great 2264 192 none 0 80% No Slab -on -Grade 6 office bed 3 1560 160 none 0 80% No Slab -on -Grade 7 bedroom 2 1123 145 none 0 80% No Slab -on -Grade 8 storage 82.5 29 none 0 80% No Slab -on -Grade 9 Garage 1615 112 none 0 80% No Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 11 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Inside Finish: Gypsum Board R-23 Wall (W.23.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-23 None / None 0.066 Cavity / Frame: R-23 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. 0. C. R-0 None / None 0.277 Cavity / Frame: no insul. / 2x4 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofbedroom 1 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofguest 1 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofBunk Room Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Attic RooflVain Wood Framed Roof Deck: Wood bedroom 1 Attic Roofs Ceiling 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 12 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U-factor Assembly Layers R-value R-value Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofgreat Attic Roofs 2x4 @ 24 in. O. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofoffice bed 3 Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. AVMW Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofbedroom 2 Attic Roofs C4@ R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic Roofstorage Attic Roofs 2x4 @ 24 in. 0. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Roofing: Light Roof (Asphalt Shingle) Wood Framed Roof Deck: Wood Attic RoofGarage Attic Roofs 2x4 @ 24 in. O. C. R-19 None / None 0.052 Siding/sheathing/decking Ceiling Cavity / Frame: R-13.0 / 2x4 Under Roof Joists: R-6.0 insul. Ceilings (below Wood Framed Over Ceiling Joists: R-34.9 insul. R-44 attic) Ceiling 2x4 @ 16 in. 0. C. R-44 None / None 0.022 Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 13 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) Standard Distribution System DHW Heater 1 (2) n/a None n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Heating Tank Energy Tank Standby Loss # of Input Rating Insulation 1st Hr. Rating NEEA Heat Pump Tank Location or Name Element Tank Type Vol. Factor or or Recovery Type Units (gal) Efficiency or Pilot R-value Eff or Flow Rate Brand or Model Ambient Condition (Int/Ext) DHW Heater 1 Gas Consumer 2 0 0.99-UEF <= 200 0 n/a n/a n/a n/a Instantaneous kBtu/hr WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Not Required Not Required Not Required None Not Required Not Required Not Required Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 14 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count HVACbed 1 3T1 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 1 Air Distribution Setback New NA 1 1 System 1 System 1 System 1 HVACgst 1 5T2 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Air Distribution Setback New NA 1 1 System 2 System 2 System 2 HVACbunk5t 3t3 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 3 Air Distribution Setback New NA 1 1 System 3 System 3 System 3 HVACmainbed 5T4 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 4 Air Distribution Setback New NA 1 1 System 4 System 4 System 4 HVACgreat 2-4T5 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 5 Air Distribution Setback New NA 2 2 System 5 System 5 System 5 HVACoffice5 T6 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 6 Air Distribution Setback New NA 1 1 System 6 System 6 System 6 HVACbed 2 4TON7 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 7 Air Distribution Setback New NA 1 1 System 7 System 7 System 7 HVAC storage8 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 8 System 8 HVAC garage9 Heat pump heating cooling Heat Pump Heat PumpSystem n/a n/a Setback New NA 1 1 9 System 9 Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 15 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Central split HP 1 8 35500 21300 16 13 Not Zonal Single Heat Pump System Speed 1-hers-htpump Heat Pump System 2 Central split HP 1 8 55500 33360 16 13 Not Zonal Single Heat Pump System Speed 2-hers-htpump Heat Pump System 3 Central split HP 1 8 55500 33300 16 13 Not Zonal Single Heat Pump System Speed 3-hers-htpump Heat Pump System 4 Central split HP 1 8 55500 33360 16 13 Not Zonal Single Heat Pump System Speed 4-hers-htpump Heat Pump System 5 Central split HP 2 8 45500 27300 16 13 Not Zonal Single Heat Pump System Speed 5-hers-htpump Heat Pump System 6 Central split HP 1 8 55500 33360 16 13 Not Zonal Single Heat Pump System Speed 6-hers-htpump Heat Pump System 7 Central split HP 1 8 45500 27300 16 13 Not Zonal Single Heat Pump System Speed 7-hers-htpump Heat Pump System 8 Ductless 1 10 14000 9100 18 12.1 Not Zonal Single Heat Pump System MiniSplit HP Speed 8-hers-htpump Heat Pump System 9 Ductless 1 9.5 39000 25350 18 12.5 Not Zonal Single Heat Pump System MiniSplit HP Speed 9-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes No Yes Yes 1-hers-htpump Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 16 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes No Yes Yes 2-hers-htpump Heat Pump System Required 350 Required Required Yes No Yes Yes 3-hers-htpump Heat Pump System Required 350 Required Required Yes No Yes Yes 4-hers-htpump Heat Pump System Required 350 Required Required Yes No Yes Yes 5-hers-htpump Heat Pump System Required 350 Required Required Yes No Yes Yes 6-hers-htpump Heat Pump System Required 350 Required Required Yes No Yes Yes 7-hers-htpump Heat Pump System Not Required 0 Not Required Not Required Yes No Yes Yes 8-hers-htpump Heat Pump System Not Required 0 Not Required Not Required Yes No Yes Yes 9-hers-htpump HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Leakage HERS Verification Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 Tested System Duct 1-hers-d ist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 Tested System Duct 2-hers-dist Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 17 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return BypasDucts Duct Leakage HERS Verification Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 Tested System Duct 3-hers-dist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 Tested System Duct 4-hers-dist Air Air Distribution N0 Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 5 Tested System Duct 5-hers-dist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 6 Tested System Duct 6-hers-dist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non Verified R 8 R 8 Attic Attic n/a n/a Bypass System 7 Tested System Duct 7-hers-dist Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 18 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design g Ducts Handler Conditioned Space Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 1-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 2-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 3-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 4-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 5-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 6-hers-dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 7-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.4 HVAC Fan 1-hers-fan HVAC Fan 2 HVAC Fan 0.4 HVAC Fan 2-hers-fan HVAC Fan 3 HVAC Fan 0.4 HVAC Fan 3-hers-fan Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 19 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 4 HVAC Fan 0.4 HVAC Fan 4-hers-fan HVAC Fan 5 HVAC Fan 0.4 HVAC Fan 5-hers-fan HVAC Fan 6 HVAC Fan 0.4 HVAC Fan 6-hers-fan HVAC Fan 7 HVAC Fan 0.4 HVAC Fan 7-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.4 HVAC Fan 2-hers-fan Required 0.4 HVAC Fan 3-hers-fan Required 0.4 HVAC Fan 4-hers-fan Required 0.4 HVAC Fan 5-hers-fan Required 0.4 HVAC Fan 6-hers-fan Required 0.4 HVAC Fan 7-hers-fan Required 0.4 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 07 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness - SRE IAQ Recovery Effectiveness - ASRE HERS Verification SFam IAQVentRpt 394 0.35 Exhaust n/a n/a Yes Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: Moonbeam lot 61B Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-11-28T15:10:08-08:00 (Page 20 of 20) Input File Name: Moonbeam -Madison lot 61B-Radford-21.ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott ;N'4--!Z0zr Company: Signature Date: Scott Design and Title 24, Inc. 2022-11-28 15:16:47 Address: CEA/ HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2022-11-28 15:16:47 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 222-P010229539A-000-000-0000000-0000 Registration Date/Time: HERS Provider: 2022-11-28 15:16:47 ME .10 0 _ Easy to Verify at CaICERTS.com CaICERTS inc. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-11-28 15:12:02 Schema Version: rev 20200901