BRES2016-0319 Title 241
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Madison Custom Residence
Lot 68B - Madison Club
La Quinta, CA 92253
Project Designer:
Hayer Architects
445 Marine View Ave., Suite 280
Del Mar, CA 92014
(858) 752-2800
Report Prepared by:
Jon Scott
Scott Design and Title 24, ln
74-81 8 Velie Way, STE I
Palm Desert, CA 92260
(760) 702-5406
CI TY OF LA QUINTA
BU ILDING & SAFETY DEPT"
/\PPR VED
F,Oil CONS UCTION
Iah>
Job Number:
8V==; m*:;; z Od:*j ,.J, Z
:^ : o fn
-c2 -@ m€-l=-, u2-t
Date:
10t26t2016
The EnergyPro compuler program has been used to pe.form the calculations summarized in this compliance report. This program has approval and is
authorized by the Califomia Energy Commission tor use with both the Residential and Nonresidenlial 2013 Building Energy Efliciency Standards.
This program developed by Energysofr, LLC - r.$r ,rr.energyson.com.
EnergyPro 6.7 by EnergySoft User Number: 6712 ID
lsh-
I
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-O1-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
16
18
22
26
30
34
EnergyPro 6.7 by EnergySoft .165 1r1urn6sr lD:User Number: 67'l 2
{t
CERTIFICATE OF COMPLIANCE . RESIDENTIAL PERFORTIANCE COiIPLIANCE METHOD
Project Name: Madison Lot 688 Custom Residence Calculatlon Date/Time: 15:27, \ ed, Oct 26, 2016
Calculatlon D6cription: Title 24 Analysis lnput Flle Name: Madison Lot 688-Hayer-'l6.xml
CFlR-PRF-01
Page 1 of 13
Ct*, lf ' r. -, ;],.-fq
COiri, ...: : . ..:. i-:,,=.+i,ivlENT
Registration Number: 2't6-No4oo4o4A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-04072016-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 75:28:49
GENERAL INFORMATION
Madison Lot 68B Custom Residence01Project Name
fille 24 AnalysisCalculation Description
Project Location Lot 688 - Madison Club
Compliance 2015La Quinta 05 Standards VersionCity
BEMCmpMgr 2013-4 (744)Compliance Manager Version92253Zip Code
EnergyPro 6.6cz15Software VersionClimate Zone
110Front Orientation (deg/Cardinal)Single FamilyBuilding Type
1Newly Constructed Number of Dwelling UnitsProject Scope
49956Number of ZonesTotat Cond. Floor Area (ft2)
9956Stab Area (ft2)
N/AAddition Cond. Floor Area
zuH{eEqsAddition Slab Area (ft2)N/A
COMPLIANCE RESULTS
Building Complies with Computer Performance01
02 This building incorporates features that require field testlng and/or verification by a certified HERSrate6r
03 This building incorporates one or more Special Features shown below
rrrrrrgrrrr
rrrrrgrg
ENERGY USE SUMMARY
04 05 06 07 08
Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent lmprovement
Space Heating 3.74 2.78 0.96 25.7o/o
Space Cooling 84.68 84.39 o.29 0.3%
IAQ Ventilation 0.65 0.65 0.00
\-ttIrt' ]u*{ r L-l \.p 0%-\
Water Heating 2.58 -0.29 I \I-',,.-*o :i*. I V_llr.g|-t
Photovoltaic Offset 0.00 0.00
Compliance Energy Total 91.65 90.69 0.96 ,iO\/0&^lgq[w"/" I
ff
I .l
}D III\IT^
Wri.':;l'
\/ I tLll\f 7. ."' '\"
cf a CEC-approve d HERS provider.
<
2.87
CERTIFICATE OF COI'PLIANCE . RESIDENTIAL PERFORi'ANCE COiIPLIANCE METHOD
Prciect Namo: Madison Lot 688 Custom Residence Calculatlon Date/Time: 15:27, \ Ed, Oct 26, 2016
Calcutation Descrlptlon: Title 24 Analysis lnput File Name: Madison Lot 688-Hayer-16.xml
CF1R.PRF.O1
Page 2 ot 13
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis
. Cool roof
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
Registration Number: 216-N04oo4o4A-ooooo0000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720t6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5',28:49
HERS FEATURE SUMMARY
provided in the building components tables below.
Building-level Verifications:. High Quality lnsulation lnstallation (Qll). IAQ mechanical ventilation
Coolin g System Verifications:. Minimum Airflow. Verified EER. Verified SEER. Refrigerant Charge. Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:. Duct Sealing. Verified low-leakage ducts entirely ln conditioned space
Domestic Hot Water System Verifications:. -- None --
ENERGY DESIGN RATING
on-site renerable energy system.
Reference Energy Use Energy Design Rating Margin Percent lmprovement
Total Energy (kTDV/f2-yr).124.90 123.94 0.96 0.8%
BUILDING . FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Madison Lot 688 Custom
Residence 9956 1 5 4 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System I Water Heating System 2
great room Conditioned HVAC1,2&3grt1 4920 11 DHW Sys 1
master Conditioned HVAC 4 mstr2 1812 11 DHW Sys 1
bedroom Conditioned HVAC 5 bed3 1474 11 DHW Sys 1
guest Conditioned HVAC 6 gst4 1750 11 DHW Sys 1
CERTIFICATE OF COi'PLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
PrcJect Name: Madison Lot68B Cuslom Residence Calculation DatorTlme: '15:27, V!bd, Oct26, 2016
Calculatlon Description: Title 24 Analysis lnput Flle Name: Madison Lot 68B-Hayer-16.xml
CFlR.PRF-01
Page 3 of 13
cfry o FLA QUIN IACUILDiNG&SA FETYIf'1
,--J,PR OV DEPI
FUR CONS E D]-RU CI,ON
BY
Registration Number: 216-N04o04o4A-000000000-0000
CA Building Energy Efficiency Standards - 2OL3 Residential Compliance
Registration Date/Time: zoi6-10-2615:34:05
Report Version - CFlR-040720t6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
D*rr
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (ft2)Tilt (deg)
20d Wall great room R-21 Wall (W.21.2x6. 16)20 Right 1 360 612.5 90
1'l0d Wall great room R-21 Wall (W.21.2x6.16)110 Front 980 478.5 90
200d Wall great room R-21 Wall (W.21.2x6.16)200 Left 1 830 90
290d Wall great room R-21 Wall (W.21.2x6.16)290 Back 1 360 427.2 90
Roof 2 great room R-38 Roof Flat 4830
20dWall2 master R-21 Wall (W.21.2x6.16)20 Right 1280 223.6 90
110d Wall 2 master R-21 Wall (W.21.2x6.1 6)110 Front 120 12 90
200d Wall2 master R-21 Wall (W.21.2x6.16)200 780 211.9 90
290d Wall2 master R-21 Wall (W.21.2x6. 16)290 Back 1 080 249.6 90
Roof 3 master R-38 Roof Flat 1812
20d Wall 3 bedroom R-21 Wall (W.21.2x6.16)20 Right 1044 267.6 90
110d Wall 3 bedroom R-21 Wall (W.21.2x6.16)110 Front 100 0 90
200d Wall3 bedroom R-21 Wall (W.21.2x6.16)200 Left 380 0 90
290d Wall3 bedroom R-21 Wall (W.21.2x6.16)290 100 0 90
Roof 4 bedroom R-38 Roof Flat 1474
N Wall guest R-21 Wall (W.21.2x6.16)0 - specify -810 243 90
E Wall guest R-21 Wall (W.21.2x6.16)90 - specify -810 25.9 90
S Wall guest R-21 Wall (W.21.2x6.16)180 - specify -810 60 90
200d Wall4 guest R-21 Wall (W.21 .2x6. 1 6)200 Left 216 42.9 90
WWall guest R-21 Wall (W.21.2x6.16)270 - specify -9B 29.7 90
290d Wall4 guest R-21 Wall (W.21.2x6. 1 6)290 Back 216 55 90
Roof 5 guest R-38 Roof Flat 1750
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot688 Custom Residence Calculation Date/Time: 15:27, \ /ed, Oct26,20'16
Calculation Descriplion: Title 24 Analysis lnput File Name: Madison Lot 688-Hayer-16.xml
Registration Number: 216-N04o04o4A-oooooo000-0000
CA Building Energy Efficiency Standards - 2OL3 Residential Compliance
Registration Date/Time: 2oi6-10-2615:34:05
Report Version - CFlR-040720L6-7 44
CF1R.PRF.O1
Page 4 of 13
HERS Provider: CaICERTS inc.
Report Generated at: 20L6-10-26 L5:28:49
OPAQU E SURFACES - Cathedral Geilings
01 02 03 04 05 07 08 09 10 11
Name Zone Type
Orientatio
n Area (ft2)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof Tilt
(deg)
Roof
Reflectance
Roof
Emiftance
Framing
Factor
Roof great room R-38 Roof Flatl - specify -90.1 90 0 0 0 0.62 0.81 0.1
545.4
Left
Back
06
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic great room Attic Roofgreat room Ventilated 0 0.81 Yes Yes
Attic master Attic Roofmaster Ventilated 0 0.62 0.81 Yes Yes
Attic bedroom Attic Roofbedroom Ventilated 0 0.62 0.81 Yes Yes
Attic guest Attic Roofguest Ventilated 0 0.62 0.81 Yes Yes
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORi'ANCE COMPLIANCE i'ETHOD
Prclsct Name: Madison Lot 688 Custom Residence Calculation DaterTlme: 15:27, l bd, Oct 26, 2016
Calculation Descriptlon: Title 24 Analysis lnput File Name: Madison Lot 68B-Hayer-16.xml
CF1R.PRF.O1
Page 5 of 13
CITY OF LA QUINTAEUILDING &SAFETY D EPT.
,IisP RCV EDf.Cft CO NSTRU CTION
BY
Registration Number: 216-N04o04o4A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CF 1R-040720L6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2015-10-26 L5:28:49
0.62
' l'.,h
WINDOWS
01 o2 03 04 05 06 07 08 09 10
Name Type Su rface (Orientation-Azimuth)width (ft)Height (ft)
Multipli
er
Area
(ft2)U-factor SHGC Exterior Shading
12d Window 20d Wall (Right20)1 159.5 0.32 o.24 lnsect Screen (default)
02w \Mndow 20d Wall(Right-20)1 77.0 0.31 0.26 lnsect Screen (default)
02d Window 20d Wall (Right-20)1 352.0 o.32 0.24 lnsect Screen (default)
24d Window 110d Wall (Front-110)1 55.0 0.32 0.24 lnsect Screen (default)
15w Window 1 10d Wall (Frontl 10)1 1 15.5 0.31 0.26 lnsect Screen (default)
17w Window 1 10d Wall (Front-1 10)1 55.0 0.31 0.26 I nsect Screen (derfault)
01 d \l/indow 1 10d Wall (Front-1 10)1 198.0 0.32 0.24 lnsect Screen (default)
01 w Window 1 10d Wall (Front-1 '10)1 55.0 0.31 0.26 lnsect Screen (derfault)
Window 200d Wall (Left-200)1 352.0 0.32 0.24 I nsect Screen (de:fault)
09d Window 200d Wall (Left-200)1 93.0 0.32 o.24 lnsect Screen (default)
03w Wndow 200d Wall (Left-200)1 37.2 0.31 o.26 lnsect Screen (default)
04w 200d Wall (Left-200)1 63.2 0.31 0.26 lnsect Screen (delfault)
05d Window 290d Wall (Back-290)1 97.2 4.24 lnsect Screen (delfault)
11d 290d Wall (Back-290)1 55.0 0.32 o.24 lnsect Screen (default)
13 d Window 290d Wall (Back-290)1 275.0 o.32 0.24 lnsect Screen (default)
Skylight Skylight Roof (- specify -95)1 90.0 0.39 0.19
08w Wndow 20d Wall2 (Right-20)1 64.0 0.31 0.26 lnsect Screen (default)
07w Window 20d Wall2 (Right-20)1 21.0 0.31 lnsect Screen (default)
16d Window 20d Wall2 (Right-2O)1 33.3 0.32 0.24 lnsect Screen (dc'fault)
08b w Window 20d Wall2 (Right-20)1 72.0 0.31 lnsect Screen (dt-'fault)
17d \Mndow 20d Wall 2 (Right-2O)1 33.3 0.32 0.24 lnsect Screen (default)
08c w Window 110d Wall 2 (Front-110)1 12.0 0.31 lnsect Screen (default)
14a d Window 200d Wall 2 (Left-200)1 152.0 0.32 0.24 lnsect Screen (dr:fault)
15a d Window 200d Wall 2 (Left-200)1 59,9 0.32 0.24 lnsect Screen (default)
14b d Wndow 290d Wall2 (Back-290)1 73.2 0.32 0.24 lnsect Screen (default)
15b d Window 290d Wall2 (Back-290)164.4 0.32 0.24 lnsect Screen (drefault)
08a w \Mndow 290d Wall2 (Back-290)1 12.0 0.31 0.26 lnsect Screen (default)
09w Window 20d Wall 3 (Right-20)1 13.8 0.31 0.26 lnsect Screen (d,efault)
19 d Window 20d Wall 3 (Right-20)1 120.0 0.32 o.24 lnsect Screen (default)
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Projact Name: Madison Lot 688 Custom Residencs Calculation Date/Time: '15:27, I6d, Oct 26, 2016
Calculation Descrlptlon: Title 24 Analysis lnput File Name: Madison Lot 668-Hayer-16.xml
CF1R.PRF.O1
Page 6 of 13
Registration Number: 216-N04o04o4A-ooooooooo-0000
CA Building Energy Efficiency Standards - 20L3 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720L6-7 44
HERS Provider: CaICERTS inc
Report Generated at: 2015-10-26 LS 28:49
25d
Window
0.32
Window
0.26
0.26
0.26
1
CERTIFICATE OF COMPLIANCE . RESIDENTIAL PERFORMANCE COiIPLIANCE METHOD
Project Name: Madison Lot 688 Custom Residence Calculation Date/Time: 15:27, t^bd, Oct26,2016
Calculation D$cription: Title 24 Analysis lnput File Nam6: Madison Lot 688-Hayer-16.xml
CFlR-PRF-o1
Page 7 ot 13
crry o FLA QUIN IAjuiLDIAJG&SA I-
I ETY DpfTCVE EFT
F"0j{CONS rR DUCIION
BY
Registration Number: 216-N04o04o4A-oooooo0oo-0000
CA Building Energy Efficiency Standards - 20L3 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720t6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
20d Window 20d Wall 3 (Right-20)1 120.O o.32 0.24 lnsect Screen (default)
10w Window 20d Wall 3 (Right-20)1 13.8 0.31 0.26 lnsect Screen (default)
21 d Window N Wall (- specify --0)1 143.0 0.24 lnsect Screen (default)
22d Window N Wall (- specify --0)1 100.0 0.32 0.24 lnsect Screen (default)
11w Window E Wall (- specify -90)1 5.9 0.31 0.26 lnsect Screen (default)
12w Wndow E Wall (- specify -90)1 20.0 0.31 0.26 lnsect Screen (default)
13w Window S Wall (- specify --180)1 60.0 0.31 0.26 lnsect Screen (default)
14b w Window 200d Wall4 (Left-200)1 42.9 0.31 0.26 lnsect Screen (default)
14aw W Wall (- specify --270)1 29.7 0.31 0.26 lnsect Screen (default)
Window 290d Wall4 (Back-290)1 55.0 0.32 0.24 lnsect Screen (default)
DOORS
01 02 03 04
Name Side of Building Area (ft2)U-factor
Door 57 20d Wall 24.0 0.50
TFi t.
0.32
Window
23d
01
Construction Name
Attic Roofgreat room
R-38 Roof Flat
R-38 Roof Flatl
R-21 Wall (W.21 .2x6.1 6)
Attic Roofmaster
Attic Roofbedroom
Attic Roofguest
CERTIFICATE OF COiIIPLIANCE - RESIDEI{TIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 688 Custom Reriidence Calculatlon Date/Time: 15:27, l Gd, Oct 26, 2016
Calculatlon Description: Title 24 Analysis lnput File Name: Madison Lot 688-Hayer-16.xml
OPAQU E SU RFACE CONSTRUCTIONS
02
Surface Type
Attic Roofs
Ceilings (belovr
attic)
Cathedral Ceilin 3s
Exterior Walls
Attic Roofs
Attic Roofs
Attic Roofs
SLAB FLOORS
o2
Zone
great room
master
bedroom
guest
Registration Number: 216-No4o04o4A-ooooo0000- 1000
CA Building Energy Efficiency Standards - 2013 t esidential Compliance
Registration Date/Time: 2016-10-26't5:34:05
Report Version - CF 1R-040720L6-7 44
CFlR-PRF.O1
Page I of 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
05 06 070304
Winter Design
U-value Assembly LayersConstruction Type Framing
TotalCavity
R-value
0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Sidi ng/she ath i ng/decking
Roofing: Light Roof (Asphalt Shingle)Wood Framed Ceiling
2x4fop Chord ofRoofTruss @ 24
in. O.C.none
lnside Finish: Gypsum Board
Cavity / Frame: R-9.1 / 2x4
Over Floor Joists: R-28.9 insul.2x4 @ 16 in. O.C.R38 0.025Wood Framed Ceiling
lnside Finish: Gypsum Board
Cavity / Frame: R-38 / 2x4
Roof De ck : Wood S i d i ng/she ath i ng/dtt cki ng
Roofing: Light Roof (Asphalt Shingle)Wood Framed Ceiling 2x4 @ 16 in. O.C.R38 0.041
lnside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: Wood
S id i ng/s he ath i ng/d e ck i ngWood Framed Wall 2x6 @ 16 in. O.C.R21 0.066
Cavity / Frcme: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)Wood Framed Ceiling
2x4Top Chord ofRoofTruss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.644
01
Name
Slab
Slab 2
Slab 3
Slab 4
,07o4050603
Perimeter (ft)Edge lnsul. R-value & Depth Carpeted Fraction HeatedArea (ft2)
0.8 No4920285None
167 None 0.8 lNo1812
None 0.8 No't474 75
No1750153None0.8
BUILDING ENVELOPE . HERS VERIFICATION
01 02 03 04
Quality lnsulation lnstallation (Qll)Quality lnstallation of Spray Foam lnsulation Building Envelope Air Leakage CFM50
Required Not Required Not Required
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORIIIANCE COMPLIANCE iIETHOD
Proiect Name: Madison Lot 688 Custom Residence Calculalion DaterTime: 15:27, VGd, Oct26,2O'16
calculatlon Description: Title 24 Analysis lnput File Namc: Madison Lot 68B-Hayer-16.xml
CF1R.PRF.O1
Page 9 of 13
Registration Number: 216-No4oo4o4A-ooooooooo-oooo
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720L6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHWSysl-112 DHW Pipe lnsulation, All Lines DHW Heater 1 2 0Yo
WATER HEATERS
01 02 03 04 05 05 07 08
Name Heater Element Type Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency Input Rating
Tank Exterior
lnsulation
R-value
Standby Loss
(Fraction)
DHW Heater 1 Natural Gas SmallStorage 50 0.66 40000-Btu/hr 0 0
WATER HEAT!NG . HERS VERIFICATION
01 02 03 04 05 06 07
Name Pipe lnsulation Parallel Piping Compact Distribution Point-of Use
Recirculation
Control
Central DHW
Distribution
DHWSysl-112
SPACE CONDITIONING SYSTEMS
o2 03 04 05 0601
Distribution NameSC Sys Name System Type Heating Unit Name Cooling Unit Name
Other Heating and Cooling
System Heating Component 1 Cooling Component 1 ]
uilHUGF t q
rP.l tlt nlr,^ ^ -]-1yffif"''Cooling Component 1:Heating Component 1:Air
Distribution System 1:HVAC Fan 1:1
Other Heating and Cooling
System Heating Component 2
I
I
I
I
Cooling Component 2 ,r!1t4ffi',6frHT flqp'rrs/stemz
Cooling Component 2:Heating Component 2:Air
Distribution System 2:HVAC Fan2:1
Cooling Component 3:Heating Component 3:Air
Distribution System 3:HVAC Fan 3:1
Other Heating and Cooling
System Heating Component 3
,
I
It
Cooling Component 3
Fqfrcctusfru
3'/,,",
t* LJ
Srrfli1q1D'tion
Other Heating and Cooling
System Heating Component 4 Cooling Component 4 ),tTE HVAC Fan 4 BY-*---
I
Air Distribution $ystem
,
4Cooling Component 4:Heating Component 4:Air
Distribution System 4:HVAC Fan 4:1
ru
CERTIFICATE OF COMPLIANCE . RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot688 Custom Residence Calculation Date/Time: 15:27, \ /ed, Oct26,2016
Calculation D$crlption: Title 24 Analysis lnput File Name: Madison Lot 688-Hayer-16.xml
Registration Number: 216-N0400404A-000000000-0000
CA Building Energy Efficiency Standards - 20L3 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720L6-7 44
CF1R.PRF.O1
Page 10 of 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
HVAC - HEATING UNIT TYPES
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 2 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 3 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 4 CntrlFurnace - Fuel-fired central furnace 80 AFUE
HVAC . COOLING UNIT TYPES
01 02 03 04 05 06 07
Name System Type
Efficiency
EER SEER Zonally Controlled
Multi-speed
Compressor HERS Verification
Cooling Component 1 SplitAirCond 12.7 16 Not Zonal Single Speed Cooling Component
1 -hers-cool
Cooling Component 2 SplitAirCond 12.7 16 Not Zonal Single Speed Cooling Component
2-hers-cool
Cooling Component 3 SplitAirCond 12.7 16 Not Zonal Single Speed Cooling Component
3-hers-cool
Cooling Component 4 SplitAirCond 13 16.5 Not Zonal Single Speed Cooling Component
4-hers-cool
HVAC COOLING. HERS VERIFICATION
01 02 03 04 05 05
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers-cool Required 350 Required Required Required
Cooling Component 2-hers-cool Required 350 Required Required Required
Cooling Component 3-hers-cool 350 Required Required Required
Cooling Component 4-hers-cool Required 350 Required Required Required
Required
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 688 Custom Residence Calculation Date/Time: 15:27, \ red, Oct 26, 2016
Calculation Desc ption: Title 24 Analysis lnput File Name: Madison Lot 68B-Hayer-16.xml
Registration Number: 216-No4oo4o4A-ooooooooo-oooo
CA Building Energy Efficiency Standards - 2OL3 Residential Compliance
Registration Date/Time: 2016-10-26'15:34:05
Report Version - CFlR-040720L6-7 44
CFlR.PRF-01
Page 11 of 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-10-26 L5:28:49
HVAC . DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage lnsulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 LowllCod Sealed and tested I Conditioned zone (VLL)None Air Distribution System
1-hers-dist
Air Distribution System 2 DuctsAttic Sealed and tested B Attic None Air Distribution System
2-hers-dist
Air Distribution System 3 DuctsAttic Sealed and tested 8 Aftic None Air Distribution System
3-hers-dist
Air Distribution System 4 DuctsAttic Sealed and tested I Attic None Air Distribution System
4-hers-dist
HVAC DISTRIBUTION . HERS VERIFICATION
01 02 03 04 05 06 07 08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low-leakage
Air Handler
Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required Not Required
Air Distribution System 2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required
Air Distribution System 3-hers-dist Required 6.0 Not Required Not Required Not Required Not Required
Air Distribution System 4-hers-dist Required 6.0 Not Required Not Required Not Required Not Required
HVAC - FAN SYSTEMS
04010203
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1-hers-fanHVAC Fan 1 Single Speed PSC Furnace Fan 0.58
HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan
HVAC Fan 3-hers-fanHVAC Fan 3 Single Speed PSC Furnace Fan 0.58
HVAC Fan 4 Single Speed PSC Furnace Fan 0.s8 W-hers-fan
HVAC FAN SYSTEMS. HERS VERIFICATION U Ir-
^
r'\.J ,
I
E0102
Name Verified Fan Watt Draw F
Required oHVAC Fan 1-hers-fan
HVAC Fan 2-hers-fan Required IE
RequiredHVAC Fan 3-hers-fan
0.58
CERTIFICATE OF COi'PLIANCE - RESIDENTIAL PERFORIUIANCE COMPLIANCE METHOD
Proiect Nams: Madison Lot 688 Custom Residence Calculation Date/Time: 15:27, l bd, Oct 26, 2016
Calculation Descrlptlon: TiUe 24 Analysis Input Flle Name: Madison Lot 68B-Hayer-16.xml
CF1R.PRF.O1
Page 12 of '13
HVAC Fan 4-hers-fan Required 0.58
Registration Number: 216-No4oo4o4A-000000000-0000
CA Building Energy Efficiency Standards - 2OL3 Residential Compliance
Registration Date/Time: 2016-10-26 15:34:05
Report Version - CFlR-040720t6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2015-10-26 L5:28:49
lAQ (lndoor Air Quality) FANS
05 0604030201
HERS VerificationIAQ Fan Type
IAQ Recovery
Effectiveness(%)lAQ WAttS/CFMIAQ CFMDwelling Unit
0 RequiredDefault0.25't44.56SFam lAQVentRpt
DOC UMENTATION AUTHOR'S DECLARATION STATEM E NT
1. I certify that this Certificate of Compliance documentation is accurate and complete
Documentation Author Signature
7d"zSmDocumentation Author Name:
Tim Scott
Signature Date:
2016-10-26 15:34:05
Company:
Scott Design and Title 24,lnc.
CEA/HERS Certification ldentification (lf applicable)Address:
77085 Michigan Drive
Phone:
760-200-4780
City/State/Zip:
Palm Desert, CA92211
RESPONSIBLE PERSON'S DEGLARATION STATEM ENT
I certiry the bllowing under penalty of perjury underthe laws oI the State of Caliturnia:'1. lam eligible under Division 3 of the Busin$s and ProEssions Code to accepl responsibility furlhe building design identified on this Certificate ofCompliance.
Regulations.
worksheels, calculations, plans and specifcations submitted to the enforcemenl agency for approval with this building permit application.
Responsible Designer Signature:7aa,9*Responsible Designer Name
Tim Scott
Date Signed:
2016-10-26 15:34:05
Company:
Scott Design and Title 24,lnc.
License
na
Address:
77085 Michigan Drive
Phone:
760-200-4780
City/State/Zip:
Palm Desert, CA92211
DATE
BY
IA
Pr
IB TI
0B U IU N,D N G &SA FE l-y D EAPPRoVF,Eo DfiCoNSUCoN
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot68B Custom Residence Calculatlon Date/Time: '15:27, l bd, Oct26,2016
C.lculation D8cription: Title 24 Analysis Input File Name: Madison Lot 688-Hayer-16.xml
Digla y s:tgned by CaICEBTS. This digital signeturc is ptovided in otdet to secwe the coltent of this rcgistercd document, and in no way implies Registhtion
Providet rcsponsibility fq the accuracy ol the infomation.
Registration Number: 216-N04oo4o4A-ooooooooo-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-10-2615:34:05
Report Version - CFlR-040720L6-7 44
CF1R.PRF.O1
Page 13 of 13
HERS Provider: catCERTS inc.
Report Generated at: 2015-10-26 t5:28:49
2013 Low-Rise Residential Mandato Measures Summa
Pipe for cooling system lines shall be insulated as specified in $ I 50.0O2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > l5 psig shall meet the requirements in TABLE 120.3-A.$ 1s0.00)2c
$ 150.0O3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is rvater retardant and provides shielding from solar radiation that degrades the material.
$ 1s0.0(i)3A
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
$ 150.0u)38:
$ I 50.0(n) I
$150.0(n)2: Recirculating loops serving multiple dwelling units shallmeet the requirements of $l10.3(c)5
Solar water-heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.$ 150.0(n)3
Ducts and Fans Nleasures
AII air-distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC $601.0, $602.0,
$603.0, $604.0, $605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
$605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
with mastic, tape, or other duct-closure system that meets the applicable requirements of UL l8l, UL l8 I A, or UL l8l B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than t/a inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
$150.0(m)l:
Factory-Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
$ 150.0(m)2
Field-Fabricated Duct Systems shall comply with requirements for: pressure-sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling$ 150.0(m)3-6:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.$ 150.0(m)7
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.$ 150.0(m)8
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
$ 150.0(m)9:
$150.0(m)10: Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
$ 150.0(m)l I
Mechanical systems that supply air to an occupiable space through ductwork exceeding l0 feet in length and through a thermal
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
$ 150.0(m)12.
$ 150.0(m)12
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air-handling unit fan efficacy < 0.58 WCFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
$1s0.0(m)13
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
an airflow from the dwelling, through the air handler fan and delivered to the dlvelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air-handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
$ 150.0(m)15
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Buildine Ventilation.
$ 150.0(o)
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.$ 150.0(o)l A
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-offswitch mounted outside of the heater that allows shutting offthe heater without adjusting the thermostat
setting; a perrnanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
$ I 10.4(a)
Systems using gas or propane water heaters to serve individual dwelling units shall include: a l20V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
space rvhere the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
2013 Low-Rise Residential Mandato Measures Summa
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and retum lines, or built-up connections for future solar heating.li l 10.4(b)l
$ I 10.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.$ l 10.4(b)3
$l r0.5:Natural gas pool and spa heaters shall not have a continuous burning pilot light.
$150.0(p): Residential pool systems or equipment shall meet specified pump sizing. flow rate, piping. filters, and valve requirements.
Lighting Measures:
$ r l0.e All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of $l10.9.
Installed luminaires shall be classified as high-efficacy or low-efficacy for compliance with $150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-8. as applicable.$ 150.0(k) l A
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of $150.0(k).$ 150.0(k) l B:
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
$130.0(c). In residentialkitchens, the wattage of electrical boxes finished with a blank cover or where no electricalequipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as I 80
watts of lorv efficacy liehtine per electrical box.
$r50.0(k)lc:
$ 150.0(k) I D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with $130.0(c). Night lights do not need to
be controlled by vacancy sensors.
$ 150.0(k)l E
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of $ 150.0(k).$ 1s0.0(k)r F
() 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires.
$150.0(k)28: Exhaust fans shall be switched separately from lighting systems.
$ 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF
$ 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions
$150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with $150.0(k).
$ 150.0(k)2F: Lighting controls comply with applicable requirements of $ I 10.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if, it functions as a dimmer
according to $l10.9; meets Installation Certificate requirements of $130.4;the EMCS requirements of $130.5; and allother
requirements in $ I 50.0(k)2.
$ 1s0.0(k)2G
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of $150.0(k) if: it
functions as a vacancy sensor according to $l10.9; meets Installation Certificate requirements of $130.4; the EMCS requirements
of $ 130.5; and all other requirements in $ 150.0(k)2.
$ 150.0(k)2H:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to $l10.9, and complies with allother applicable requirements in $150.0(k)2.$ 150.0(k)2r
$ I 50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
$ 1s0.0(k)3B
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.$ 1s0.0(k)4
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.$ 150.0(k)5:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.$ 150.0(k)6:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy. or shall be controlled by either dimmers or vacancy sensors.$ r 50.0(k)7
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (lC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualifu as high efficacy for compliance with $ 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in $l10.9.
$ 1s0.0(k)8
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
$ r 50.0(k)eA:
2013 Low-Rise Residential Mandato Measures Summa
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomicaltime clock in accordance with $l10.9; meets the Installation Certification requirements in $130.4; meets the
requirements for an EMCS in $130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residentialparking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with $150.0(k)9A; or
ii. Shall comply with the applicable requirements in $110.9, $130.0, $130.2. $130.4, $140.7 and til4l.0.
$ r50.0(k)9B:
For lorv-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by $150.0(k)98 or 150.0(k)9D
shall comply with the applicable requirements in $l10.9, $130.0. {i130.2. $130.4, $140.7 and $141.0.$ 150.0(k)ec:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in $l10.9, $130.0, $130.2, $130.4, $140.7 and gl4l.0.$ r 50.0(k)eD:
Internally illuminated address signs shall comply with $ 140.8; or shall consume no more than 5 watts of power as determined
according to $ 130.0(c).$ l s0.0(k) l0
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in $110.9, $130.0, li130.1, $130.4, $140.6. and $141.0.$ 150.0(k)ll:
In a low-dse multifamily residential building where the total interior common area in a single building equals 20 percent or less of
$ 150.0(k) l2A: the floor are4 permanently installed lighting for the interior common areas in that building shall be high elTicacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building rvhere the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in $110.9, $130.0, $130.1, S140.6 and $141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shallbe capable of turning the light fully On and Off from all designed paths of
ingress and egress.
$ls0.0(k)r2B
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January l, 2014,
shallcomply with the requirements of $l10.10(b) through $l10.10(e).
$l 10.10(a)l
$l10.10(a)2: Low-rise multi-family buildings shall comply with the requirements of $l10.10(b) through $l10.10(d)
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway. smoke
ventilation, and spacing requirements as specified in Title 24,Parl9 or other Parts of Title24 or in any requirements adopted by a
localjurisdiction. The solar zone total area shallbe comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equalto 10.000 square feet or no less than 160 square feet each for
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi-family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than l5 percent of the total roof area of the building excluding any skylight area.
$ l 10.10(b) l
$l 10.10(b)2: All sections ofthe solar zone located on steep-sloped roofs shall be oriented between I l0 degrees and 270 degrees oftrue north
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shallbe
located in the solar zone.$r 10.10(b)3A
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
$l10.10(b)38
For areas of the roof designated as solar zone, the structuraldesign loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.$r 10.10(b)4
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water-heating
system.
$l 10.10(c)
A copy of the construction documents or a comparable document indicating the information from |)l10.10(b) through $l10.10(c)
shall be provided to the occupant.$ll0.l0(d)
$l10.10(e)l: The main electrical service panel shallhave a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
$l10.10(e)2
HVAC SYSTEM HEATING AND GOOLING LOADS SUMMARY
Project Name
Madison Custom Residence
Date
10t26t2016
System Name
HVAC 1,2&3grt
Floor Area
4,920
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 3 COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
Tota! Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
5,889 84,985 6,259 1,718 66,870
0
0 0
0
902 35,517 7,693 902 42,23
8,830 -8,830
0
TOTAL SYSTEM LOAD 129,332 13,952 100,276
Heating System
Output per System 89,000
Total Output (Btuh)267,000
Output (Btuh/sqft)54.3
Coolinq System
Output per System 57,500
Total Output (Btuh)172,500
Total Output (Tons)14.4
Total Output (Btuh/sqft)35.1
Total Output (sqfUTon)342.3
Air System
CFM per System 2,000 HVAC EQUIPMENT SELECTION
Airflow (cfm)6,000 Carrier 24ANA760/58PH..1 1 0 130,936 29,432 267,000
Total Adjusted System Output
(Adjusted for Peak Design conditions)
130,936 29,432
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Airflow (cfm/sqft)1.22
Airflow (cfmlTon)417.4
Outside Air (%)15.0 o/o
Outside Air (cfm/sqft)0.18
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 0F 63 0F 65 0F 107 0F
Outside Air
902 cfm Supply Fan
6,000 cfm
Heating Coil 107 0F
RooM ffi
70 0F 70 0F
EI-I I E
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 t78'F 81t670F 82l68"F 61 /600F
Outside Air
902 cfm
E I-t I E +
Supply Fan
6,000 cfm
Cooling Coil 61 / 60.F
RooM tr
75 / 65',F 75/650FEIII E
I
59.6 %
EneryyPro 6.7 by EnergySoft User Number: 6712 RunCode : 201 6-1 0-2671 5 :29 :23 ID Page 22 of 39
267,000
H Eltth
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Madison Custom Residence
Date
10t26t2016
System Name
HVAC 4 mstr
Floor Area
1,812
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
2,41 30,431 2,787 29,024
0
1,757 1,426
0 0
332 12,789 2,267 332 15,319
2,943 -2,943
1,757 1,426
TOTAL SYSTEM LOAD 49,677 4,572 44,252
Heating System
Output per System 89,000
Total Output (Btuh)89,000
Output (Btuh/sqft)
Cooling System
Output per System 57,500
Total Output (Btuh)57,500
Total Output (Tons)4.8
Total Output (Btuh/sqft)31.7
Total Output (sqfUTon)378.2
Air System
CFM per System 2,000 HVAC EQUIPMENT SELECTION
Airflow (cfm)2,000 Carrier 24ANA760/58PH*.1 1 0 44,499 9,681 89,000
Total Adjusted System Output
(Adjusted for Peak Design conditions)
44,499 9,681 89,000
TIME OF SYSTEM PEAK Aug 3 PM Jan 1AM
Airflow (cfm/sqft)1.'10
Airflow (cfm/Ton)417.4
Outside Air (%)16.6 %
Outside Air (cfm/sqft)0.18
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 0F 620F 64 0F 105 0F
Outside Air
332 cfm
H EI-t th
105 0F
@
Supply Fan
2,000 cfm
Heating Coil
69 0F 70 0F
EIII E
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 I 78 0F 82 I 68oF 83 / 69.F 62 I 61 "F
Outside Air
332 cfm
IE I
Supply Fan
2,000 cfm
Cooling Coil 63 / 6'1 0F
tr
76/660F 75/660FEIIIE
I I
!
61.5 %ROOM
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode : 201 6-1 0-26T1 5 :29 :23 ID:Page 23 of 39
49.1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Madison Custom Residence
Date
10t26t2016
System Name
HVAC 5 bed
Floor Area
1,474
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
97 15,949 1,875 15,280
0
921 751
0 0
270 10,485 3,493 270 12,527
0 0
921 751
TOTAL SYSTEM LOAD 28,275 5,368 29,309
Heating System
Output per System 71,000
Total Output (Btuh)71,000
Output (Btuh/sqft)48.2
Cooling System
Output per System 49,000
Total Output (Btuh)49,000
Total Output (Tons)4.1
Total Output (Btuh/sqft)33.2
Total Output (sqfUTon)361.0
Air System
CFM per System 1,600 HVAC EQUIPMENT SELECTION
Airflow (cfm)1,600 Carrier 24AN 8748-58 PH""090 38,430 6,315 71,000
Total Adjusted System Output
(Adjusted for Peak Design conditions)
38,430 6,315 71,000
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Airflow (cfm/sqft)1.09
Airflow (cfm/Ton)391.8
Outside Air (%)16.9 %
Outside Air (cfm/sqft)0.18
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
260F 62 0F 620F 104 0F
Outside Air
270 cfm Supply Fan
1,600 cfm
Heating Coil 103 0F
@
70 "F70 0F
EIIIE
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 I 78 0F 82t67"F 82t670F 59/58oF
Outside Air
270 cfm
EIITE
Supply Fan
1,600 cfm
Cooling Coil 60/580F
tr
76 t640F 75 t640F
ETITE
I
54.8 o/o ROOM
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode : 201 6-1 0-26T1 5 :29 :23 ID:Page 24 of 39
429
E Ettt-
I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Madison Custom Residence
Date
10t26t2016
System Name
HVAC 6 gst
Floor Area
1,750
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
1,640 23,472 2,226 24,806
0
1,355 1,219
0 0
321 12,416 3,025 321 14,828
0 0
1,355 1,219
TOTAL SYSTEM LOAD 38,598 5,251 42,072
Heating System
Output per System 1 10,000
Total Output (Btuh)110,000
Output (Btuh/sqft)62.9
Cooling System
Output per System 58,000
Total Output (Btuh)58,000
Total Output (Tons)4.8
Total Output (Btuh/sqft)33.1
Total Output (sqfUTon)362.1
Air System
CFM per System 2,000 HVAC EQUIPMENT SELECTION
Airflow (cfm)2,000 Carrier 24AN 8760-58PH**1 1 0-20 43,752 9,866 1 10,000
Total Adjusted System Output
(Adjusted for Peak Design conditions)
43,752 9,866 1 10,000
TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM
Airflow (cfm/sqft)1.14
Airflow (cfm/Ton)413.8
Outside Air (%)16.0 Yo
Outside Air (cfm/sqft)0.18
Note: values above qiven at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 0F 620F 620F 114 0F
Outside Air
321 cfm Supply Fan
2,000 cfm
Heating Coil 114 0F
@
7A oF69 0F
EIIIE
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 t78"F 81 /670F 81t67"F 61/60"F
Outside Air
321 cfm
EIII E ------l
62/600F,@
75 / 65.F
Supply Fan
2,000 cfm
Cooling Coil
58.6 %
76/650F EIIIE
I
Ru n Code : 201 6-1 0-2671 5 : 29 : 23 tD.EnergyPro 6.7 by EnergySoft User Number: 6712 Page 25 of 39
t ^.l r.G- ^ \L ^-
535
H Et.tth
r---'
ROOM LOAD SUMMARY
Project Name
Madison Cu stom Residence
Date
10/26/2016
System Name
HVAC1,2&3grt
Floor Area
4,920
ROOM LOAD SUMMARY
ROOIVI COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name fi/ult.CFM Sensible Latent CFIVI Sensible Latent CFM Sensible
great room Great Room Living area h 1 5,889 84,985 6,259 5,889 84,985 6,259 1,718 66,870
PAGE TOTAL
TOTAL -
. Total includes ventilation load for zonal systems.
EnerovPro 6.7 bv EnerqvSoft User Number: 6712 Ru n Code : 201 6-1 0-26T1 5 : 29 :23 ID:Paqe 26 of 39
5,889 84,985 1,71 66,870
5,889 84,985 1,71 66,870
ROOM LOAD SUMMARY
Project Name
Madison Cu stom Residence
Date
10/26/2016
System Name
HVAC 4 mstr
Floor Area
1 ,812
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult.CFM Sensible Latent CFM Sensible Latent CFM Sensible
master Master bedroom 1 2,410 30,431 2,305 2,410 30,431 2,305 787 29,024
PAGE TOTAL
TOTAL -
* Total includes ventilation load for zonal systems.
EnergvPro 6.7 by EnergvSoft User Number: 6712 Ru nC ode : 201 6- 1 0-26T1 5 :29 :23 ID:Pase 27 of 39
2,410 30,431 29,024
2,410 30,431 29,024
ROOM LOAD SUMMARY
Project Name
M adi son C u stom Resrdence
Date
10/26/2016
System Name
HVAC 5 bed
Floor Area
1 ,474
ROOM LOAD SUMMARY
ROO[/ COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Mult CFM Sensible Latent CFM Sensible Latent CFTVI Sensible
bedroom Bedrooms 2 & 3 1 978 15,949 1,875 978 15,949 1,875 429 15,280
PAGE TOTAL
TOTAL -
. Total includes ventilation load for zonal systems
EneruvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode: 2016-10-26715:29:23 ID:Paqe 28 of 39
Room Name
ROOM LOAD SUMMARY
Project Name
M adi son Cu stom Resldence
Date
10/26/2016
System Name
HVAC 6 gsf
Floor Area
1,750
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult CFM Sensible Latent CFM Sensible Latent CFM Sensible
guest Guest Room quarters 1 1,640 23,472 2,226 1,640 23,472 2,226 535 24,806
PAGE TOTAL
TOTAL -
* Total includes ventilation load for zonal systems
EneruvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode: 2016-10-26715:29:23 ID Pase 29 of 39
1,640 23,472 24,806
1,640 23,472 24,806
ROOM HEATING PEAK LOADS
Project Name
M adison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name Great Room Living area Kitchen
Floor Area 4,920.0 ftz
tndoor Dry Bulb Temperature 70 oF
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT "F Btu/hr
4,830.0
90.0
3,466.4
1,636.7
402.9
24.0
perim = 285.0
788.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.3900
0.0690
0.3200
0.3100
0.5000
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Items shown with an asterisk (.) denote conduction through an interior surface to another room Page Total
tnfittration:I x x /60] x 44
Fraction
44
44
44
44
44
44
44
0
1.00 1.064 4,920 11.00 0.262x
ng
x
AT
66,870TOTAL HOURLY HEAT LOSS FOR ROOM
30 of 39
R-38 Roof Flat 5,526
Skylight 1,544
R-21 Wall (W.21.2x6.1 6)10,524
tint Metal....32/.24 23,045
dual tint Metal....31 /.26 5,496
Wood Door 528
9,154
*R-0 lnteiorWall 0
55,816
11,053
ROOM HEATING PEAK LOADS
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Master bedroom
1,912.0 ft2
70 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT
OF Btu/hr
1,812.0
2,562.9
181.0
516.1
perim = 167.0
596.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.3100
0.3200
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
44
44
44
44
44
0
Items shown with an asterisk (-) denote conduction through an interior surface to another room Page Total
!nfiltration:I x x 1,812 /60] x 44
e H
Fraction
1.0641.00 11.00 0.262
Area
x
ng Height
x
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 29,024
7 ID 31 39
ROOM HEATING PEAK LOADS
Date
10/26/2016
Project Name
M adison Custom Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Bedrooms 2 & 3
1,474.0 ftz
70 0F
Time ol Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT
OF Btu/hr
1,474.0
1,356.4
27.6
240.0
peim = 75.0
410.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.3100
0.3200
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Items shown with an asterisk (.) denote conduction through an interior surface to another room Page Total
lnfiltration:I 1.00 x 1.064 x 1,474 x 11.00 x 0.262 /60I x 44
Schedule
Fraction
Air Sensible Area Ceiling Height ACH AT
44
44
44
44
44
0
TOTAL HOURLY HEAT LOSS FOR ROOM 15,280
326.7 User Number: 6712 6-ID:
(
Roof Flat 1,686
R-21 Wall (W.21.2x6.16)4,1 18
wndw dual tint Metal....31 /.26 376
dual tint Metal....3Z.24 3,379
Slab-On-Grade 2,409
*R-0 lnteriorWall 0
11,969
3,311
ROOM HEATING PEAK LOADS
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Guesf Room quafters
1,750.0 ft2
70 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT OF Btu/hr
1,750.0
2,503.5
298.0
158.5
perim = 153.0
410.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.3200
0.3100
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
44
44
44
44
44
0
Items shown with an asterisk (") denote conduction through an interior surface to another room Page Total
!nfiltration:I 1.00 x 1.064 x 1,750 /60] x 44
Schedule
Fraction
Air Sensible
11.00 0.262
Area
x
ing Height
x
H AT
TOTAL HOURLY HEAT LOSS FOR ROOM 24,806
1
39
t
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name Great Room Living area Kitchen
Floor Area 4,920.0 ft'z
Indoor Dry Bulb Temperature 75 oF
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
ue Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(E)
(N)
(N)
(E)
(s)
(W
4,830.0
747.5
24.0
501.5
1,284.6
932.8
788.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.5000
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
56.0
25.7
25.7
32.1
28.2
31.8
0.0
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(E)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(E)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
15.1
15.3
15.8
15.3
15.3
15.8
15.8
15.3
15.8
+
+
+
+
+
+
+
+
+
x
x
x
x
x
x
x
x
x
Page Total
Internal Gain Btu/hr
4,920
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x 0.89 x 248.02 x 37
CFM ELA AT
90.0
159.5
77.0
352.0
55.0
115.5
55.0
198.0
55.0
40.8
18.7
19.6
18.7
28.5
30.1
30.1
28.5
30.1
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 84,985
Latent Gain Btu/hr
14.8 Occupants X 155
lnfiltration:4,771 x 0.89 x 248.02 x 0.00376
Air Sensible CFM ELA AW
Btuh/occ
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,288
EnerqvPro 6.7 bv EnemvSofr User Number: 6712 RunCode: 201 6-1 0-2671 5:29 :23 ID Paqe 34 of 39
M
=Or,Or"n,
-l
14.8
2,
3,971
)
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name Great Room Living area Kitchen
Floor Area 4,920.0 ft2
lndoor Dry Bulb Temperature 75 oF
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
Surfaces Orientation Area U-Factor CLTDl Btu/hr
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(s)
(s)
(s)
(s)
(W
(w
(w
0.0
0.0
0.0
0.0
0.0
0.0
0.0
x
x
x
x
15.3
15.3
15.8
15.8
15.3
15.3
15.3
+
+
+
+
+
+
+
+
+
x
x
x
x
x
x
x
x
x
Page Total
lnternal Gain Btu/hr
14.8
4,920
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:1.064 x 0.89 x x 37
Air Sensible CFM ELA AT
352.0
93.0
37.2
63.2
97.2
55.0
275.0
17.8
17.8
18.5
18.5
26.7
26.7
26.7
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 84,985
Latent Gain Btu/hr
Occupants 14.8 Occupants X 155
!nfiltration:x 0.89 x 248.02 x 0.00s76
Air ble CFM ELA AW
4,771
Btuh/occ.
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,288
EnerqvPro 6.7 bv EnemvSoft User Number: 6712 RunCode:2016-10-26715:29:23 lD Paqe 35 of 39
25d 6,263
09d 1,
03w 690
04w 1,
05d 2,591
11d 1,466
13d
21
3,61
248.02 8,
2,
3,971
t
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Master bedroom
1,812.0 ft2
75 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
ue Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(E)
(N)
(E)
(s)
1,812.0
1,056.4
108.0
568.1
830.4
596.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
56.0
25.7
32.1
28.2
31.8
0.0
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(N)
(N)
(N)
(N)
(N)
(E)
(s)
(s)
(w
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
15.8
15.8
15.3
15.8
15.3
15.8
15.3
15.3
15.3
+
+
+
+
+
+
+
+
+
x
x
x
x
x
x
x
x
x
Page Total
I lnternal Gain Btu/hr
5.4
1,812
Occupants
Floor Area
x
x
245
0.50
Btuh/occ
w/sqft
lnfiltration:x 0.89 x 91.34 x 37
Air CFM ELA AT
64.0
21.0
33.3
72.0
33.3
12.0
152.0
59.9
73.2
19.6
19.6
18.7
19.6
18.7
30.1
17.8
17.8
26.7
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,431
Latent Gain Btu/hr
5.4 Occupants X 155
lnfiltration:4,771 x 0.89 x 91.34 x 0.00376
Air Sensible CFM ELA AW
Btuh/occ
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 843
EneravPro 6.7 bv EneruvSoft User Number: 6712 RunCode : 201 6-1 0-26T1 5:29 :23 ID Paqe 36 of 39
(w
Occupants
t
t RESIDENTIAL ROOM GOOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Master bedroom
1,812.0 ft2
75 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
ue Surfaces Orientation Area U-Factor CLTDl Btu/hr
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(W
(W
0.0
0.0
x
x
x
x
x
x
x
x
x
15.3
15.8
+
+
+
+
+
+
+
+
+
164.4
12.0
x
x
x
x
x
x
x
x
x
26.7
28.1
Page Total
Internal Gain Btu/hr
5.4
1,812
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x x 91.34 x 37
Air Sensi FM ELA AT
0.891.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,431
Latent Gain
5.4 Occupants X 155
lnfiltration:4,771 x 0.89 x 91.34 x 0.00376
Air Sensible CFM ELA AW
Btuhiocc.
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 843
EnerqvPro 6.7 bv EneruvSofr User Number: 6712 RunCode:2016-10-26715:29:23 lD:Paqe 37 of 39
15b d 4,382
08a w 338
4,
3,
3,2
Btu/hr
1,462
t
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Bedrooms 2 & 3
1,474.0 ftz
75 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(E)
(N)
(E)
(s)
(W
1,474.0
776.4
100.0
380.0
100.0
410.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(N)
(N)
(N)
(N)
0.0
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
1s.8
15.3
15.3
15.8
+
+
+
+
+
+
+
+
+
13.8
120.0
120.0
13.8
x
x
x
x
x
x
x
x
x
19.6
18.7
18.7
19.6
Page Total
lnternal Gain Btu/hr
4.4
1,474
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x x 74.31 x 37
M ELA AT
56.0
25.7
32.1
28.2
31.8
0.0
1.064 0.89
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,949
Latent Gain Btu/hr
4.4 Occupants X 155
lnfiltration:4,771 x 0.89 x 74.31 x 0.00376
Air Sensible CFM ELA AW
Btuh/occ
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 685
Paqe 38 of 39EnerqvPro 6.7 bv EnerqvSofr User Number:6712 RunCode:2016-10-26T15:29:23 lD:
R-38 Roof Flat 2,
R-21 Wall (W.21.2x6.16)1
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
*R-0 lnteriorWall
4,
09w
19d 2,248
20d 2,248
10w 270
2,51
2,61
1
RESIDENTIAL MEASURES SUMMARY RMS.1
Project Name
Madison Custom Residence
Building Type E Single Family tr Addition Alone
tr Multi Family tr Existing+ Addition/Alteration
Date
10/26/2016
Project Address
Lot 688 - Madison Club La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. FloorArea
9,956
Addition
n/a
# of Units
1
INSULATION
Construction Type Cavity
Area
ff(l Special Features Status
Roof Wood Framed Attic R38 9,866 CoolRoof New
Wall Wood Framed R21 9,889 New
Door Opaque Door - no insulation 24 New
S/ab U nheated Slab-on-G rade - no insulation 9,956 Perim = 680'New
Demising Wood Framed - no insulation 2,492 New
FENESTRATION
Orientation Area(t(l U-Fac SHGC Overhang Sidefins Exterior Shades Status
Skytight 90.0 0.390 0.19 none none None New
Risht (N)818.1 0.320 0.24 none none Bug Screen New
Risht (N)261.6 0.310 0.26 none none Bug Screen New
Front (E)253.0 0.320 0.24 none none Bug Screen New
Front (E)237.5 0.310 0.26 none none Bug Screen New
Left (S)656.9 0.320 0.24 none none Bug Screen New
Left (S)143.3 0.310 0.26 none none Bug Screen New
Rear (W)719.8 0.320 0.24 none none Bug Screen New
Rear (W)12.0 0.310 0.26 none none Bug Screen New
Right (N)243.0 0.320 0.24 none none Bug Screen New
Front (E)25.9 0.310 0.26 none none Bug Screen New
Left (S)60.0 0.310 0.26 none none Bug Screen New
Rear (W)29.7 0.310 0.26 none none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
3 CentralFumace 80% AFUE Split Air Conditioner ,6.0 SEER Sefback New
1 CentralFumace 80% AFUE Split Air Conditioner 76.0 SEER Sefback New
1 CentralFumace 80o/o AFUE Split Air Conditioner 76.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating Cooling Duct Location
Duct
R-Value Status
HVAC1,2&3grt Ducted Ducted Conditioned 8.0 New
HVAC 4 mstr Ducted Ducted Attic 8.0 New
HVAC 5 bed Ducted Ducted Attic 8.0 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 SmallSforage Gas 50 0.66 All Pipes lns New
EnemvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode: 201 6-10-2671 5:29:23 ID:Paqe 16 of 39
CERTIFICATE OF COMPLIANCE . RESIDENTIAL PERFORMANCE COMPLIANCE iIETHOD
Project Name: Madison Lot 688 Custom Resid€nce caleulatlon DaterTime: 15:27, \
^9d,
oct 26, 20'16
Calculation Description: Title 24 Analysis lnput File Name: Madison Lot 688-Hayer-16.xml
CFlR-PRFJO1
Page 13 of 13
DOC U M ENTATION AUTHOR'S DECLARATION STATEM ENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author SignatureDocumentation Author N ame
Jon Scott
Signature Date:
10t26t2016
Company:
Scott Design and Title 24,lnc,
CEA/HERS Certification ldentification (lf applicable)
74-818 Velie Way, STE IAddress
{e, 7o2 54ooPhonecitv/stateKjt'm
Desert, cA 92260
ia:ofState ifornCalfolltheowiunderoftheunderoflawsthecertifongpenaltyperjury,
ofCertificate a ce.nonsProfessiodeCbtofobuilddonidentifiedthis1elamibleDunder3ivisiontheofnessBusiandCompliacceptresponsiilityingesignig
ofend6ParttheofaCCodlifornia1toconformtheTitleofPart24ianceandSidentifiedcationsthisonCertificaterequirements2thethatfeaturesperformancepecificertiffenergy
ons.Regulati
comicablereaistentconsthewithinformationotheron documents,of3 pliancebuTheitdifeaturesrofeaturenidentifiedSCertificatethisonprovidedapplngdesigndesigsystem
worksheets, calculations, plans and specifications submitted to the enforcement age approval with this building permit application.
RESPONSIBLE PERSON'S DECLARATION STATEMENT
Responsible Designer Signature:Responsible Designer Name:
Hayer Architects
Date SignedCompany:
Hayer Architects o#j*'
License
445 Marine View Ave., Suite 280 $Address:
Phone
(858) 752-2800
City/State/Zip:
Del [\Iar, CA 92014 ^s
Registration Number:
CA Building Energy Efficiency
sJ
,9
,,.^#r13 Residentiat comptiance
Registration Date/Ti me :
Report Version - CF 1R-04072016-7 44
HERS Provider:
Report Generated at: 2015-10-26 15:28:38
RESIDENTIAL MEASURES SUMMARY RMS.1
Project Name
Madison Cu stom Residence
Building Type El Single Family tr Addition Alone
tr Multi Family tr Existing+ Addition/Alteration
Date
10/26/2016
Project Address
Lot 688 - Madison Club La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
9,956
Addition
n/a
# of Units
1
INSULATION
Construction Type Cavity
Area
(ffi Special Features Status
FENESTRATION
Orientation Area(f(l U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Coolins Min. Eff Thermostat Status
1 CentralFumace 80% AFUE Split Air Conditioner 76.5 SEER Setback New
HVAC DISTRIBUTION
Location Heating Cooling Duct Location
Duct
R-Value Status
HVAC 6 gst Ducted Ducted Attic 8.0 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnemvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode: 201 6-10-2671 5:29:23 ID,Paqe 17 of 39
2013 Low-Rise Residential Mandatory Measures Summary
NqIE; Lov-lise residential buildings subjecl lo the Standatds musl cotlply with all applicable ondatory measures listed, regardless of the
used.Review the re,code section r more
Building Envelope Measures:
$ I 10.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage
Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of $ I 0- I I I (a).$ I 10.6(a)s
$l10.7 Exterior doors and windows are weatherstripped; alljoints and penetrations are caulked and sealed.
$l10.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of {i I 10.8(i) when the
installation of a cool roof is specified on the CFIR.$ l r0.8(i):
$l10.8(i): A radiant barrier shallhave an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood-frame ceiling; or the weighted average U-factor shall not exceed 0.03 I . Minimum R- l9 in a
rafter roof alteration. Attic access doors shallhave permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
$ 150.0(a)
$150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
Minimum R-13 insulation in 2x4 inch wood framing wallor have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).$ 150.0(c)
$ 150.0(d)Minimum R-19 insulation in raised wood-frame floor or 0.037 maximum U-factor
In Climate Zones l4 and l6 a Class II vapor retarder shallbe installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air-permeable insulation.$ 1s0.0(g) I
In Climate Zones l-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.$ 1s0.0(e)2
In a building having a controlled ventilation crawl space, a Class I or Class ll vapor retarder shall be placed over the earth floor of
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.37o;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of $l10.8(g).
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.$ 150.0(q)
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
$ 150.0(e)lA: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tieht-fitting damper or a combustion-air control device.$ 150.0(e) I B:
$150.0(e)lC: Masonry or factory-built fireplaces have a flue damper with a readily accessible control.
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building. are prohibited.$ 150.0(e)2
Space Conditioning, Water Heating and Plumbing System Measures:
$l10.0-$l t0.3: fryAC equipment, water heaters, shou€rheads, faucets and all other regulated appliances are certified to the Energy Commission
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of $ I 10.3(c)5.$ I 10.3(c)5
Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
$l l0.s
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in $150.0(h)2.$ 150.0(h) r :
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.$ 150.0(h)3A:
$ 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of $ I 10.2(c)
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.$150.00lA:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.$ r 50.00)l B:
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 314 inch or larger, all piping associated with a domestic hot water recirculation system
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
$ l s0.0o2A:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non-crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.$ 150.0(i)28
$ 150.0(e)3:
$ 1s0.0(l):
;
!RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Madison Custom Residence
Date
10/26/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Guesf Room quarters
1,750.0 ftz
75 0F
Outdoor Dry Butb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
ue Surfaces Orientation Area U-Factor CLTDl Btu/hr
(E)
(N)
(E)
(s)
(s)
(w
(W
1,750.0
567.0
784.1
750.0
173.1
68.3
161.0
410.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room1. Cooling Load Temperature Ditference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(N)
(N)
(E)
(E)
(s/
(s)
(w
(W
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
15.3
15.3
15.8
15.8
15.8
15.8
15.8
15.3
+
+
+
+
+
+
+
+
+
x
x
x
x
x
x
x
x
x
Page Total
lnternal Gain Btu/hr
5.2
1,750
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:1.064 x 0.89 x 88.22 x 37
Air Sensible CFM ELA AT
56.0
23.0
33.0
26.0
28.2
33.0
31.8
0.0
143.0
100.0
5.9
20.0
60.0
42.9
29.7
55.0
15.3
15.3
31.3
31.3
15.9
18.5
31.3
26.7
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,472
Latent Gain Btu/hr
Occupants 5.2 Occupants X 155
Infiltration:4,771 x 0.89 x 88.22 x 0.00376
Air Sensible CFM ELA AW
Btuh/occ
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 814
EnerqvPro 6.7 bv EnerovSofi User Number: 6712 Ru n Code : 201 6-1 0-26T1 5 : 29 :23 ID Paqe 39 of 39
a
R-38 Roof Flat 2,
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)1
R-21 Watl (W.21.2x6.16)1
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
*R-0 lnterior Wall
21 d 2,189
22d 1,531
11w 185
12w 626
13w 955
14b w 795
14a w 929
23d 1,466
I,
1
3,