BRES2016-0240 Title 24 - 2013 Code Updateo
o
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Mr. & Mrs. Swenson
The Enclave
La Quinta, CA92253
Project Designer:
Prest Vuksic Arch itects
44-530 San Pablo Ave.
Palm Desert, Ca 92260
(760) 77e-53e3
Report Prepared by:
Tim Scott
Scott Design and Title 24,lnc,
78818 Velie Way, Suite 8
Palm Desert, CA 92260
(760) 777-0102
RECEIVED
DEC 0 7 20t6
CIW OF I.A QUINTA
COMMUNIW DEVELOPMEI
Job Numb
Date:
81212016
coMMur'l ffie$Yl$Ii'ENr
The EnergyPro computer program has been used to perform the calculalions summarized in this compliance repon. This program has approval and is
authorized by the Califomia Energy Commission for use with both the Residential and Nonresidenlial 2013 Building Energy Efficiency Standards.
This program developed by Energysofi, LLC - wt/'^,v.energysofi.com.
CIryOF
BUILDING &
I-A QUINTA
SAFETY DEPI
ll
EFOR C
APP
:
oerc2
,4.ID:EnergyPro 6.7 by EnergySoft User Number: 6712
(
I
t
1T
a
TABLE OF CONTENTS
EnergyPro 6.7 by EnergySoft ID User Number: 6712
Cover Page
Table of Contents
Form CF-1 R-PRF-O1-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R lVlandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Zone Load Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
16
18
22
26
30
34
39
t
GENERAL INFORMATION
01 Project Name Mr. & Mrs. Swenson
Calculation Description fille 24 Analysis
03 Project Location The Enclave
04 Caty La Quinta 05 Standards Version Compliance 2015
06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 20134 (744)
08 Climate Zone cz15 09 Software Version EnergyPro 6.6
10 Building Type Single Family 11 Front Orientation (deg/Cardinal)340
12 Project Scope Newly Constructed 13 Number of Dwelling Units 1
14 Total Cond. Floor Area (ft2)5203 15 Number of Zones 5
16 Slab Area (fli)5203 17 Number of Stories 1
18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes
20 Addition Slab Area (fli)N/A 21 Glazing Percentage (%)33.0%
csnrrfe or coMpLrANcE - REsTDENTTAL eERFoRMANcE coMplrANce JrooProlect Name: Mr. & Mrs. Swenson Calculation Date/Time: 15:43, Tue, Aug 02, 20'16
Calculation Description: Ti0e 24 Analysis lnput Flle Name: Swenson-Pv-16.xml
Registration Number: 21 6-N0288589A-000000000-0000
CA Building Energy Efficiency Standards - 201,3 Residential Compliance
Registration Date/Time: 2016-08-02 't6:33:03
Report Version - CFlR-04072Oi6-7 44
cQnr -01
Page 1 of 13
HERS Provider: CaICERTS inc.
Report Gene rateC at: 2016-08 -02 15:44:36
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 Thia building incorporate. f.alur€! that rcquire liold t sting andror verification by . co.tified HERS r.ter under the 3upervirion of . CEc-approved HERS provlder.
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05 06 07 08
Energy Use (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin Percent lmprovement
Space Heating 3.14 -1.23 -6/..4%
Space Cooling 96.56 96.49 0.07 O-1Yo
IAQ Ventilation 0.77 0.77 0.00 0.0%
Water Heating 4.93 2.73 2.20 44.6%
Photovoltaic Offset 0.00 0.00
Compl iance Energy Total 104.17 103.13 1.04 1.0%
02
1.91
nt:r,:"xtlllll*=t''=*rrAL PERFoRMANce couer-rmrcEolrDon
o"anm", 1s:43, rue, Aus 02,2016
Calculatlon Description: Title 24 Analysis lnput File Name: Swenson-Pv-16.xml
.f*r-0,
Page 2 ot 13
REQU!RED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
. Window overhangs and/or fins
HERS FEATURE SUMMARY
provided in the building components tables below.
Building-leve! Verifi cations :. High Quality lnsulation Installation (Qll). IAQ mechanical ventilation
Cooli ng System Verifications:. Minimum Airflow. Verified EER. Verified SEER. Refrigerant Charge. Fan Efficacy Watts/CFM
HVAC Distribution System Verifi cations:. Duct Sealing. Ducts located entirely in conditioned space
Domestic Hot Water System Verifications:. - None --
ENERGY DESIGN RATING
on-site renewable €nergy syst€m.
Reference Energy Use Energy Design Rating Margin Percent lmprovement
Total Energy (kTDV/f2-yr).140.71 139.67 1.04 0.7Yo
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING . FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)
Number of Dwelling
Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mr. & Mrs. Swenson 5203 1 4 5 0 1
Registration Number: 21 6-N0288s89A-000000000-0000
CA Builcing Energy Efficiency Standards -20t3 Residential Compiiance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CFlR-04072075 744
HERS Provider: calcERTS inc
Report Generated at: 2016-08-02 L5: A:35
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height Water Heating System 1 Water Heating System 2
Master Conditioned HVAC 1.I 919 I DHW Sys 1
Guest 1 Conditioned HVAC 22 380 I DHW Sys 1
Office/Utility Conditioned HVAC 22 361 9 DHW Sys 1
Living Area Conditioned HVAC 3 & 43 2610 I DHW Sys 1
Roark & Sloan Conditioned HVAC 44 933 I DHW Sys 1
cennfe or coMpuANcE - REsTDENnAL pERFoRxrANcE coMplrANce ]oo
Proiec-t lfame: Mr. & Mrs. Swenson Cil-culation Date/Time: 15:43, Tue, Aug 02, 2016
Calculation Description: Tide 24 Analysis Input File Name: Swenson-pv-,l6.xml
cfnr-or
Registration Number: 21 6-N0288589A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CFlR-040720L6-7 44
Page 3 of 13
HERS Provider: CaICERTS inc
Report Generated at: 2016-08-02 15:44:36
OPAQUE SURFACES
01 o2 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window & Door Area (#)Tilt (deg)
N Wall Master R-21 Wall (W.21.2x6.16)0 - specify -25 0 90
70d Wall Master R-21 Wall (W.21.2x6.1 6)70 Left 468 176.172 90
160d Wall Master R-21 Wall (W.21.2x6.16)0 - specify -163 104.4 90
350d Wall Master R-21 Wall (W.21.2x6.1 6)350 - specify -42 0 90
Roof Master R-38 Roof(R.38.2x1 4. 1 6)919
E Wall Guest 1 R-21 Wall (W.21.2x6.16)90 - specify -215 69.3006 90
Roof 2 Guest 1 R-38 Roof(R.38.2x1 4. 1 6)380
N Wall2 Office/Utility R-21 Wall (W.21.2x6.16)0 - specify -207 0 90
E Wall 2 Office/Utility R-21 Wall (W.21.2x6.16)90 - specify -238 45 90
Roof 3 Office/Utility R-38 Roof(R.38.2x1 4. 1 6)361
N Wall 3 Living Area R-21 Wall (W.21.2x6.16)0 - specify -65 44.1 90
160d Wall 2 Living Area R-21 Wall (W.21.2x6.16)160 Back 672 326 90
240d Wall Living Area R-21 Wall (W.21.2x6.16)240 - specify -175 55.5 90
250d Wall Living Area R-21 Wall (W.21.2x6.16)45 - specify -240 28.4084 90
270d Wall Living Area R-21 Wall (W.21.2x6.1 6)270 - specify -554 417 90
330d Wall Living Area R-21 Wall (W.21.2x6.1 6)240 - specify -48 34.7904 90
340d Wall Living Area R-21 Wall (W.21.2x6.1 6)u0 Front 174 144.791 90
Roof 4 Living Area R-38 Roof(R.38.2xl 4. 1 6)2610
60d Wall Roark & Sloan R-21 Wall (W.21.2x6.1 6)60 - specify -395 20 90
150d Wall Roark & Sloan R-21 Wall (W.21.2x6.1 6)150 - specify -68 0 90
24OdWall2 Roark & Sloan R-21 Wall (W.21.2x6.1 6)240 - specify -440 120.44 90
330d Wall 2 Roark & Sloan R-21 Wall (W.21.2x6.16)330 - specify -310 132.887 90
Roof 5 Roark & Sloan R-38 Roof(R.38.2x1 4. 1 6)933
cenrrfe or coMpLrANcE - REsTDENTTAL eERFoRMANcE coMpuANce froo
Proiect Name: Mr & Mrs, Swenson Calculation Date/Time: 15:43, Tue, Arg 02, 2016
Calculatlon DeEcriptlon: Tifle 24 Analysis lnput Flle Name: Swenson-Pv-16.xml
Registration Number: 2i6-N02885894-000000000-0000
CA Building Energy Efficiency Standards - 2OI3 Residential Cornpliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CF1 R-0407 201-6-7 Ll
crfnr-or
Page 4 ot 13
HERS Provider: CaICERTS inc
Report Generated at: 2016-08-02 1,5:44:36
ATTIC
01 02 03 o4 05 06 07 08
Name Gonstruction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Coo! Roof
Attic Master Attic RoofMaster Ventilated 4.36764 0.1 0.85 Yes No
Attic Guest 1 Attic RoofGuest 1 Ventilated 4.36764 0.1 0.85 Yes No
Attic Office/Utility Attic RoofOffi ce/Utility Ventilated 4.36764 0.1 0.85 Yes No
Attic Living Area Attic RoofLiving Area Ventilated 4.36764 0.1 0.85 Yes No
Attic Roark & Sloan Attic RoofRoark & Sloan Ventilated 4.36764 0.1 0.85 Yes No
cenrrfe or coirplrANcE - RESTDENnAL eERFoRMANcE coMpuANce lroo
Prorect lfam.: Mr. & Mrs. Swenson Calculation Date/Time: 15:43, Tue, Aug 02,2016
Calculation Description: Title 24 Analysis lnput File Name: Swenson-Pv-'l6.xml
cr|nr-or
Registration Number: 216-N0288S89A-oooo0ooo0-o0oo
CA Builcing Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CF1 R-0407201,6-7 44
Page 5 of 13
HERS PrOvidcr: CaICERTS inc.
Report Generated at: 2016-08-A2 15:44:36
i
WINDOWS
01 02 03 04 05 06 07 08 09 10
Name Type Surface (Orientation-Azimuth)width (ft)Height (ft)
Multipli
er
Area
(ft2)U-factor SHGC Exterior Shading
12 Window 70d Wall(Left-70)1 100.8 0.40 0.32 !nsect Screen (default)
13 Window 70d Wall (Left-70)1 7.8 0.40 0.32 lnsect Screen (default)
14 Window 70d Wall (Left-7O)17.8 3.8 0.999 67.6 0.40 0.32 lnsect Screen (default)
15 Window 160d Wall (- specify -0)1 1.6 9.0 1 104.4 0.40 0.30 lnsect Screen (default)
10 Window E Wall (- specify -90)8.0 8.0 1 64.0 0.40 0.30 lnsect Screen (default)
11 Window E Wall (- specify -90)2.3 2.3 1.002 5.3 0.40 0.32 lnsect Screen (default)
8 Window E Wall 2 (- specify -90)1 22.5 0.48 0.32 lnsect Screen (default)
I Window E Wall 2 (- specify -90)1 22.5 0.48 0.32 lnsect Screen (default)
7 Window N Wall 3 (- specify -0)4.9 9.0 1 44.1 0.40 0.32 lnsect Screen (default)
16 Window 160d Wall2 (Back-160)32.6 10.0 1 326.0 0.40 0.30 lnsect Screen (default)
18 Window 240d Wall (- specify --240)15.0 3.7 1 55.5 0.40 0.32 lnsect Screen (default)
17 Window 250d Wall (- specify 45)8.6 3.3 1.001 28.4 0.40 0.32 lnsect Screen (default)
2 Window 270dWall (- specify --270)41.7 10.0 1 417.0 0.40 0.32 lnsect Screen (default)
22 Window 330d Wall (- specify --240)4.8 8.0 0.906 34.8 0.40 0.32 lnsect Screen (default)
A Window 340d Wall (Front340)3.0 10.0 1 30.0 0.56 0.31 lnsect Screen (default)
1 Window 340d Wall (Front-340)2.9 10.0 1 29.0 0.40 0.32 I nsect Screen (default)
12 Window 340d Wall (Front-340)2.9 10.0 1 29.0 0.40 0.32 lnsect Screen (default)
13 Window 340d Wall (Front-340)8.7 4.5 1.001 39.2 0.40 0.32 lnsect Screen (default)
14 Window 340d Wall (Front-340)8.7 1.5 1.004 13.1 0.40 0.32 lnsect Screen (default)
15 Window 340d Wall (Front340)3.0 1.5 1 4.5 0.40 0.32 lnsect Screen (default)
24 Window 60d Wall (- specify -60)2.5 8.0 1 20.0 0.40 0.32 lnsect Screen (default)
19 Window 240d Wall 2 (- specify --240)1 35.0 0.40 0.32 lnsect Screen (default)
20 Window 240d Wall 2 (- specify -240)17.8 4.8 1 85.4 0.40 0.32 lnsect Screen (default)
21 Window 330d Wall 2 (- specify --330)9.0 10.0 1 90.0 0.40 0.30 lnsect Screen (default)
23 Window 330d Wall 2 (- specify -330)8.1 5.3 0.999 42.9 0.48 0.32 I nsect Screen (default)
cennQe or coMpuANcE - REsTDENTIAL pERFoRlrANcE coupLrANce lroo
Projoct Name: Mr. & Mrs. Swenson Calculation Date/Time: 15:43, Tue, AJg 02,20'16
Calculation D$criptlon: Title 24 Analysis lnput Flle Name: Swenson-Pv- l6.xml
cQnr -01
Registration Number: 21 6-N02885894-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CFlR-040720L6-7 44
Page 6 of 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08 -02 75:44:36
OVERHANGS AND FINS
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Overhang Left Fin Right Fin
Window Depth Dist Up
Left
Extent
Right
Extent Flap Ht.Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up
14 3 0.1 3 3 0 0 0 0 0 0 0 0 0
15 10 0.1 10 10 0 0 0 0 0 0 0 0 0
10 3 0.1 3 3 0 0 0 0 0 0 0 0 0
11 4 0.1 4 4 0 0 0 0 0 0 0 0 0
7 0.1 3 3 0 0 0 0 0 0 0 0 0
16 15 0.01 15 15 0 0 0 0 0 0 0 0
18 4 0.1 4 4 0 0 0 0 0 0 0 0 0
17 4 0.1 4 4 0 0 0 0 0 0 0 0
2 3 0.1 3 3 0 0 0 0 0 0 0 0 0
22 2 0.1 2 2 0 0 0 0 0 0 0
A 6 0.1 6 b 0 0 0 0 0 0 0 0 0
1 6 0.1 6 6 0 0 0 0 0 0 0 0 0
12 6 0.1 6 6 0 0 0 0 0 0 0 0
13 6 0.1 6 6 0 0 0 0 0 0 0 0 0
14 6 0.1 6 6 0 0 0 0 0 0 0 0 0
15 6 0.1 6 b 0 0 0 0 0 0 0 0 0
24 2 0.1 2 2 0 0 0 0 0 0 0 0 0
20 4 0.1 4 4 0 0 0 0 0 0 0 0
21 8 0.1 8 8 0 0 0 0 0 0 0 0 0
23 5 0.1 5 5 0 0 0 0 0 0 0 0 0
cenrrfe or coMpLrANcE - RESTDENTTAL eERFoRMANcE coirpLrANce Jroo
Proiect ilame: Mr & Mrs. Swenson Calculation Date/Time: 15:43, Tue, Aug 02, 2016
Calculatlon Descdption: Tifle 24 Analysis lnput File Name: Swenson-Pv-16.xml
Registration Number: 216-N0288589A-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CFlR-04072016 744
cQnr -01
Page 7 ot 13
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08-02 t5:44:36
3
0
0
0 0
0
0
:ff1:f.:i::"#1fli.1;"tt'o=*rrAl
PERF.RMANce couer-rmceor"ouiDon
o"t"nr,", is:43, rue, Ais 02,2016
Calculatlon Description: Title 24 Analysis lnpul File Name: Swenson-PV-16.xml
"Q*r-o''Page 8 of 13
OPAQUE SURFACE CONSTRUCTIONS
01 o2 03 04 05 06 07
Construction Name Surface Type Construction Type Framing
TotalCavity
R-value
Winter Design
U-value Assembly Layers
Attic RoofMaster Attic Roofs Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decki ng
Roofing: Light Roof (Asphalt Shingle)
R-38 Roof(R.38.2x,1 4. I 6)
Ceilings (below
attic)Wood Framed Ceiling 2x4 @ 16 in. O.C.R38 0.025
lnside Finish: Gypsum Board
Cavity / Frame: R-9.1 / 2x4
Over Floor Jorsfs: R-28.9 rnsu/.
R-21 Wall (W.21.2x6. 16)Exterior Walls Wood Framed Wall 2xG @ 16 in. O.C.R21 0.066
lnside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Erterior Finish: Wood
S i d i n g/sh e ath i ng/d e cki ng
Attic RoofGuest'1 Attic Roofs Wood Framed Ceiling
2x4Top Chord of Roof Truss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
Attic RoofOffice/Util ity Attic Roofs Wood Framed Ceiling
2x4Top Chord of Roof Truss @ 24
in. O.C.none o.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
Attic Roofliving Area Attic Roofs Wood Framed Ceiling
2x4Top Chord of RoofTruss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
Attic RoofRoark & Sloan Attic Roofs Wood Framed Ceiling
2x4Top Chord of Roof Truss @ 24
in. O.C.none 0.644
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01 02 03 04 05 06 07
Name Area (ft2)Perimeter (ft)Edge lnsul. R-value & Depth Carpeted Fraction Heated
Slab Master 919 140 None 0.8 No
Slab 2 Guest 1 380 82 None 0.8 No
Slab 3 Office/Utility 361 96 None 0.8 No
Slab 4 Living Area 2610 162 None 0.8 No
Slab 5 Roark & Sloan 933 188 None 0.8 No
Registration Number: 216-N02885894-000000000-0000
CA BurlCing Energy Efficiency Standards - 2013 Residential Compiiance
Registration Date/Time: 20i6-08-02 16:33:03
Report Version - CFL R-0407 20L6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08 -02 1,5:4a:36
Zone
cERTIOE oF coMpLrANcE - RESTDENTTAL nERFoRMANcE coMpLrANcE
Project Jfame: Mr. & Mrs. Swenson
Calculation Description: Title 24 Analysis
Date/Time: 15:43, Tue, Aug 02,2016
lnput File Name: Swenson-Pv-1 6.xml
JrooCa-lculation
cfnr-or
Page 9 of 13
BUILDING ENVELOPE . HERS VERIFICATION
01 02 03 04
Quality lnsulation lnstallation (Qll)Quality lnstallation of Spray Foam lnsulation Building Envelope Air Leakage CFM50
Required Not Required Not Required
WATER HEATING SYSTEMS
0'l 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHWSysl-112 DHW Pipe lnsulation, All Lines DHW Heater 1 2 0%
01 o2 03 04 05 06 07 08
Name Heater Element Type Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency lnput Rating
Tank Exterior
tnsulation
R-value
Standby Loss
(Fraction)
DHW Heater 1 NaturalGas Small lnstantaneous 0.7 0.95 1 99000-Btu/hr 0 0
WATER HEATING. HERS VERIFICATION
01 02 03 o4 05 06 07
Name Pipe lnsulation Paralle! Piping Compact Distribution Point-of Use
Recirculation
Contro!
CentralDHW
Distribution
DHW Sys 1- 112
SPACE CONDITIONING SYSTEMS
01 o2 03 04 05 06
SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name
Cooling Component 1:Heating Component 1:Air
Distribution System 1:HVAC Fan 1:1
Other Heating and Cooling
System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1
Cooling Component 2:Heating Component 2:Air
Distribution System 2:HVAC Fan 2:1
Other Heating and Cooling
System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2
Cooling Component 3:Heating Component 3:Air
Distribution System 3:HVAC Fan 3:1
Other Heating and Cooling
System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3
Cooling Component 4:Heating Component 4:Air
Distribution System 4:HVAC Fan 4:1
Other Heating and Cooling
System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4
Registration Number: 21 6-N0288589A-000000000-00o0
CA Building Energy Efficiency Standards - 2O!3 Residential Compliance
Registration Date/Time: 2016-08-02 r6:33:03
Report Versio n - CFlR-0407201,6-7 44
HERS Provider: CaICERTS inc
Report Generated at: 2016-08-02 15:44:36
WATER HEATERS
HVAC . HEATING UNIT TYPES
01 o2 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 2 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 3 CntrlFurnace - Fuel-fired central furnace 80 AFUE
Heating Component 4 CntrlFurnace - Fuel-fired central furnace BO AFUE
cennfe or coMpLrANcE - REsTDENTTAL eERFoRMANcE couplrANce JrooPrpiect Neme: Mr. & Mrs. Swenson Cdculation Date/Time: '15:43, Tue, Arg 02, 2016
Calculation Descdption: Title 24 Analysis lnput File Name: Swenson-PV-16.xml
Registration Number: 21 6-N02885894-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Version - CFlR-040720L6 -7 L4
-01
Page 10 of 13
HERS Provider: CaICERTS inc.
Report GenerateC at: 201.5-08-OZ t5:44:36
cQnr
HVAC. COOLING UNIT TYPES
01 02 03 04 05 06 07
Name System Type
Efficiency
EER SEER Zonally Controlled
Multi-speed
Compressor HERS Verification
Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component
1-hers-cool
Cooling Component 2 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component
2-hers-cool
Cooling Component 3 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component
3-hers-cool
Cooling Component 4 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component
4-hers-cool
HVAC COOLING. HERS VERIFICATION
01 02 03 o4 05 06
Name Verified Airflow Airflow Target Verified EER Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers-cool 350 Required Required Required
Cooling Component 2-hers-cool Required 350 Required Required Required
Cooling Component 3-hers-cool Required 350 Required Required Required
Cooling Component 4-hers-cool Required 350 Required Required Required
Required
HVAC . DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07
Name Type Duct Leakage lnsulation R-value Duct Location Bypass Duct HERS Verification
Air Distribution System 1 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System
1-hers-dist
Air Distribution System 2 DuctslnAll 8 Conditioned zone None Air Distribution System
2-hers-dist
Air Distribution System 3 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System
3-hers-dist
Air Distribution System 4 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System
4-hers-dist
"a*r'fa or
"oMpLrANcE
- RESTDENnAL eERFoRMANcE coMpLrANce froo
Project Name: Mr. & Mrs. Swenson Calculatlon Date/Time: '15:43, Tue, Alg 02,2016
Calculation Doscrlptlon: Title 24 Analysis lnput File Name: Swenson-Pv-'l6.xml
crfnror
Page 11 of 13
Registration Number: 21 6-N02885894-000000000-0000
CA BuilCing Energy Efficiency Standards - 2OL3 Residential Compiisn6s
Registration Date/Time: 2016-08-02 i6:33:03
Report Version - CF 1 R-04072OI6-7 44
HERS Provider: CaICERTS inc.
Report Generated at: 2016-08 -02 L5:4436
01 02 03 o4 05 06 07 08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low{eakage
Air Handler
Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required Not Required
Air Distribution System 2-hers-dist Required 6.0 Required Not Required Not Required Not Required
Air Distribution System 3-hers-dist Required 6.0 Required Not Required Not Required Not Required
Air Distribution System 4-hers-dist Required 6.0 Required Not Required Not Required Not Required
HVAC. FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM)HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan
HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan
HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan
HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS. HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan Required 0.58
HVAC Fan 2-hers-fan Required 0.58
HVAC Fan 3-hers-fan Required 0.58
Sealed and tested
HVAC DISTRIBUTION . HERS VERIFICATION
cERflaE oF coMpLtANcE - RES|DENT|AL PERFoRMANCE coMpLtANcE OrcD
Proiect name: Mr. & Mrs. Swenson Ca-lculation Date/Time: 15:43, Tue, Aug 02, 2016
Calculation Description: Title 24 Analysis lnpul File Name: Swenson-Pv-16.xml
.f*r-0,'
Page 12 ot 13
HVAC Fan 4-hers-fan Required 0.58
IAQ (lndoor Air Quality) FANS
01 o2 03 o4 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
IAQ Recovery
Effectiveness(%)HERS Verification
SFam lAQVentRpt 89.53 0.25 Default 0 Required
Registration Number: 21 6-N0288589A-o0000ooo0-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-08-02 16:33:03
Report Vers ion - CFlR-04072Ot6-7 44
HERS Provider: CaICERTS inc
Report Generated at: 2016-08 -02 15:44:36
--l
.ERTTOE oF coMpLrANcE - RESTDENTTAL
'ERF.RMAN.E
coMpLrANcE
Project Name: Mr. & Mrs. Swenson
Calculation Description: Title 24 Analysis
Registration Number: 216-N02885894-000000000-0000
CA BuilCing Energy Efficiency Standards - 2013 Residential Compliance
Jo,Calculation Date/Time: 15:43, Tue, Aug 02,2016
lnput File Name: Swenson-PV-1 6.xml
Registration Date/Time: 2016-08-02 '16:33:03
Report Version - CFlR-040720L6-7 L4
c
Page 13 of 13
HERS Provider: CaICERTS inc
Report Generated at: 2016-08-OZ 15:44:36
rf*ror
infomation.
DOC U MENTATION AUTHOR'S DECLARATION STATEM ENT
1. ! certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Tim Scott
Documentation Author Signature
72rrfia6
Company:
Scott Design and Title 24,lnc
Signature Date:
2016-08-02 16:33:03
Address:
77085 Michigan Drive
CEA/HERS Certification ldentification (lf applicable):
City/State/Zip:
Palm Desert, CA92211
Phone:
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certiry the tollowing under pehalty of peiury under lhe laws of the State of California:
1. I am eligible und6r Division 3 of the Business and Prcfussions Code to accepl responsibility for the building design identified on this Cortilicate ofCompliance.
Regulations.
worksheets, calculations, plans and specifications submitted to the enforcement agency forapprovalwith this building permit application.
Responsible Designer Name:
Tim Scott
Responsible Designer Signature:Tmrsadt
Company:
Scott Design and Title 24,lnc.
Date Signed:
2016-08-02 16:33:03
Address:
77085 Michigan Drive
License
NA
City/State/Zip:
Palm Desert, C492211
Phone:
760-2004780
O
o
RESIDENTIAL MEASURES SUMMARY RMS.1
Project Name
Mr. & Mrs. Swenson
Building Type E Single Family tr Addition Alone
tr Multi Family tr Existing+ Addition/Alteration
Date
8/2/2016
Project Address
The Enclave La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,203
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
(f(lGavity Special Features Status
5,203R38 NewRoof Wood Framed Attic
2,780Wood Framed R21 NewWall
- no insulation 5,203 Perim = 668'NewU n he ated S I ab-o n- G radeS/ab
Demising Wood Framed - no insulation 3,930 New
FENESTRATION
Orientation Area
none
33.0 o/o New/Altered 0.41
New
Status
1,719
0.400
U-Fac
TotalArea:U-Factor:
Left (E)108.6 none Bug Screen0.32
SHGC Overha Sidefins ExteriorShades
Left (E)67.6 0.400 0.32 3.0 Bug Screen Newnone
Front (N)104.4 0.400 0.30 10.0 Bug Screen Newnone
Left (E)64.0 0.400 0.30 3.0 Bug Scrcen Newnone
Left (E)Bug Screen5.3 0.400 none New0.32 4.0
Left (E)Bug Screen45.0 0.480 none New0.32 none
Front (N)Bug Screen44.1 0.400 Newnone0.32 3.0
Rear (S)Bug Screen326.0 0.400 Newnone0.30 15.0
Right (sW)Bug Screen140.9 New0.400 none0.32 4.0
28.4
417.0
0.400
0.400
none
none
New
New
Left (NE)
Risht (W)
Bug Screen
Bug Screen
0.32 4.0
0.32 3.0
Risht (SW)Bug Screen New34.8 0.400 none0.32 2.0
Frcnt (N)Bug Screen30.0 0.560 none New0.31 6.0
Front (N)Bug Screen114.8 0.400 Newnone0.32 6.0
HVAC SYSTEMS
Qty. Heating Min. EffMin. Eff Cooling Thermostat Status
1 CentralFumace 80% AFUE Split Air Conditioner 16.0 SEER Sefback New
1 CentralFumace 80% AFUE Split Air Conditioner 16.0 SEER Sefback New
80% AFUE Split Air Conditioner 76.0 SEER NewSefback2 Central Furnace
HVAC DISTRIBUTION
Location Heating Cooling Duct Location
Duct
R-Value Status
HVAC 1 8.0 NewDuctedDuctedConditioned
HVAC 2 8.0DuctedDuctedConditioned New
HVAC3&4 Ducted Ducted Conditioned 8.0 New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Smalllnstantaneous Gas All Pipes lns0.951 New
Ru n Code : 20 1 6-08-02T1 6 : 1 2 : 28 Paqe 16 of 44ID:EnemvPro 6.7 bv EnerqvSoft User Number: 6712
o
RESIDENTIAL MEASURES SUMMARY RMS.1
Project Name
Mr. & Mrs. Suve nson
Building Type M Single Family tr Addition Alone
tr Multi Family tr Existing+ Addition/Alteration
Date
8/2/2016
Project Address
The Enclave La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
5,203
Addition
n/a
# of Units
1
INSULAT!ON
Construction
Area
(ffiCavity Special Features Statusrype
U-Fac SHGC Overhang Sidefins Exterior Shades StatusNpafffl
FENESTRATION
Orientation
Left (NE)Bug Screen20.0 0.400 none New0.32 2.0
Risht (SW)0.400 Bug Screen35.0 none New0.32 none
Front (NW)Bug Screen90.0 0.400 none New0.30 8.0
Front (NW)42.9 0.480 Bug Screennone New0.32 5.0
HVAC SYSTEMSqy. Heating Min. EffMin. Eff Cooling Thermostat Status
1 CentralFumace 80% AFUE Split Air Conditioner 76.0 SEER Setback New
HVAC DISTRIBUTION
Location Heating Cooling Duct Location
Duct
R-Value Status
HVAC 4 8.0DuctedDuctedConditioned New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Paqe 17 of 44EnerqvPro 6.7 bv EnergySoft User Number: 6712 RunCode:2016-08-02716:12:28 lD
o
33.0 %0.41TotalArea:1,719
2013 Low-Rise Residential Mandatory Measures Summary
{Qf[; Low-rise residential bxildings subjecl lo the Standards must comply \|ith all applicable mandatory measures listed, regardless of the
lance used.Review the ctive code section more
Building Envelope Measures:
$ I 10.6(a) I : Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar IIeat Cain
Coefficient (SHGC), and infiltration that meets the requirements of g l0- I I I (a).$l10.6(a)5
$r r0.7 Exterior doors and windows are weatherstripped; alljoints and penetrations are caulked and sealed.
$110.8(a): InsulationspecifiedorinstalledmeetsStandardsforlnsulatingMaterial. IndicatetypeandincludeontheCF2R
The thermalemittance and aged solar reflectance values of the cool roofing material meets the requirements of $110.8(i) when the
installation of a cool roof is specified on the CFIR.$ l r0.8(i):
$l10.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR
Minimum R-30 insulation in wood-frame ceiling; or the weighted average U-factor shall not exceed 0.03 I . Minimum R- l9 in a
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
$ 150.0(a)
$150.0(b): Loose lill insulation shallconltrrm with manufacturer's installed design labeled R-value.
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum tJ-
factor).$ 150.0(c):
$ I 50,0(d): Minimum R- 19 insulation in raised wood-frarne floor or 0.037 maximum U-factor
In Climate Zones l4 and l6 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all extcrior
walls, vented attics and unvented attics with air-permeable insulation.
In Climate Zones l-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class Il
yapor retarder.$ 150.0(e)2
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth I'loor ol'
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
r 50.0(d).
$ I s0.0(e)3
d as part of a hgated slab floor meets the requirements of $ I 10.8(g)
$ rs0.0(r)
and when installe
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.$ 150.0(q):
Fireplaces, Decorative Gas Appliances and Gas Log Measures
$150.0(e)lA: Masonry or factory-built fireplaces have a closable metalor glass door covering the entire opening of the firebox
Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
$ I 50.0(e) I C: Masonry or factory-built fireplaces have a flue damper with a readily accessible control
$150.0(e)lB equipped with a readily accessible. operable. and tisht-fitti ng damper or a combustion-air control device.
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
$ I 50.0(e)2:of the build !!E 4re prohibited
Space Conditioning, Water Heating and Plumbing System Measures:
$l 10.0-$l 10.3: HVAC equipment, water heaters, sho\.verheads, faucets and all other rEgulated oppliances are certified to the Ener$/ Commission
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of $l10.3(c)5.$ I 10.3(c)5:
Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt). and pool
and spa healers.
$ l 10.5:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specilied
in $1s0.0(h)2.$ r 50.0(h) r
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet ol'any
dryer vent.$ r 50.0(h)3A:
$ I 50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of $ I 10.2(c).
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
n having an installed thermal resistance of R- 12 or greater.$ 150.0(J)lA with insulatio
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.$ 150.0(i)r B
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storagc
tank, allpiping with a nominaldiameter of 314 inch or larger, allpiping associated with a domestic hot water recirculation systen.l
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade. and
allhot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
) $ l50.o0)2A
All domestic hot water pipes that are buried below grade must be installed in a water proof and non-crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.$ 1s0.0()28:
$ 150.0(9) l:
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings. no greater than 0.37o:
have water vapor permeance rate is no greater than 2.0 penn/inch, be protected from physical damage and UV light deterioration:
2013 Low-Rise Residential Mandato Measures Summa
Pipe for cooling system lines shall be insulated as specified in $150.0(i)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > l5 psig shall meet the requirernents in TABLE 120.3-A.$ l s0.0o2c:
$150.0O3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind
Insulation exposed to weather shall either be rated fbr outdoor use or installed with a cover suitable fbr outdoor service. For
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specilied or
painted with coatins that is water retardant and provides shieldine from solar radiation that degrades the material.
$ r 50.0(i)3A
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
$ 150.0038:
Systems using gas or propane water heaters to serve individualdwelling units shall include: a l20V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows naturaldraining without pump assistance; and a gas supply line with a capacity ol'at least 200.000
Btu/hr.
$150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of fill0.3(c)5
$ I 50.0(n) I
Solar water-heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SIf.CC)
or by a testing agency approved by the Executive Director.$ 150.0(n)3:
Ducts and Fans Measures:
Allair-distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC $601.0, $602.0,
$603.0, $604.0, $605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
$605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connectionsofmetal ductsandinnercoreofflexibleductsaremechanicallyfastened.Openingsshallbesealed
with mastic, tape, or otherduct-closure system that meets the applicable requirements of UL l8l, UL l8lA, or UL lSlB or
aerosol sealantthatmeetstherequirementsofULT23. lf masticortapeisusedtosealopeningsgreaterthant/o inch.the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shallnot be used fbr conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforrns
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
$ 150.0(m)l
Factory-Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures:.ioints
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
$ 150.0(m)2
) $ tso.o(r)r-o Field-Fabricated Duct Systems shall comply with requirements for: pressure-sensitive tapes, mastics. sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or arutonratic
dampers.$ 1s0.0(m)7
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated darnpers
except combustion inlet and outlet air openings and elevator shaft vents.$ 150.0(m)8:
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by alurninurn.
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shieldine from solar radiation.
$150.O(m)e
$ 150.0(m)10: Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Refbrence
Residential Appendix RA3.
$ 150.0(m)l I
Mechanical systems that supply air to an occupiable space through ductwork exceeding l0 feet in length and through a therrnal
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
$ 150.0(m) 12.
$ I 50.0(m) l2
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
space conditioning system must also demonstrate airflorv > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air-handling unit fan efficacy < 0.58 WiCFM as confirmed by field verification and diagnostic testing. in
accordance with Reference Residential Appendix RA3.
$150.0(m)13:
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode.
an airflow from the dwelling, through the air handler thn and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air-handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation ol-
central forced air system air handlers used in central lan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
$ 150.0(m)15
$ 150.0(o):
) $ 1s0.0(o)l A Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater that allows shutting offthe heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
$l10.4(a):
2013 Low-Rise Residential Mandato Measures Summa
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.$ l 10.4(b)r
) $l10.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.$ r r 0.4(b)3:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
$150.0(p): Residential pool systems or equipment shall nreet specified pump sizing, flow rate, piping, filters. and valve requirements.
$r 10.5:
Lighting Measures:
$ r 10.9:All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of $ I 10.9
Installed luminaires shallbe classified as high-efficacy or low-efficacy for compliance with $150.0(k) in accordance with TABLE
150.0-4 or TABLE 150.0-8, as applicable.$1s0.0(k)lA:
When a high efficacy and low effrcacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of $ I 50.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
$130.0(c). In residentialkitchens, the waftage of electrical boxes finished with a blank cover or where no electricalequipment has
been installed, and where the electricalbox can be used for a luminaire or a surface mounted ceiling flan, shall be calculated as 180
watts of low efficacy liehtine per electrical box.
$r50.0(k)lc
$150.0(k)lD: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fhns shall be rated to consume no
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with $130.0(c). Night lights do not need to
be controlled by vacancy sensors.
$ 150.0(k)l E
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of $ 150.0(k).$ r 50.0(k)l F:
$150.0(k)2A: High efficacy luminaires must be switched separately from lowefficacy luminaires
$150.0(k)28: Exhaust f'ans shall be switched separately frorn lighting systems.
$150.0(k)2Cr Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFI:
!i 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions.
$150.0(k)2E: No control shallbypass a dimmer or vacancy sensor function if the control is installed to comply with $150.0(k).
, $ 150.0(k)2F: Lighting controls comply with applicable requirements of $ I 10.9
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
according to $l10.9; meets Installation Certificate requirements of $130.4: the EMCS requirements of $130.5; and allother
requirements in $ I 50.0(k)2.
$ 1s0.0(k)2G
)
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of $ 150.0(k) ifl it
functions as a vacancy sensor according to $ I 10.9; meets Installation Certificate requirements of $ 130.4; the EMCS requirements
of $130.5; and allother requirements in $150.0(k)2.
li r 50.0(k)2H
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to $ I 10.9, and complies with all other applicable requirements in lil50.0(k)2.$ r 50.0(k)2r:
$150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high effrcacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas. are
considered kitchen liehtine if they are not separately switched fiom kitchen I
Permanently installed lighting that is internalto cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.$ r s0.O(k)a:
ighting.
A minimum of one high efficacy luminaire shall be installed in each bathroom; and allother lighting installed in each bathroorn
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high elficacy luminaires and
controlled by vacancy sensors.
shall be h efI'icac or controlled sensors.$ r 50.O(k)s
$ r 50.0(k)6:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.$ r s0.0(k)7:
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (lC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with $ I 50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in $ I 10.9.
$ 150.0(k)8
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and autonratically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
$ r 50.0(k)eA
lir50.0(k)rB:
$ 1s0.0(k)38:
2013 Low-Rise Residential Mandato Measures Summa
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock. and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the f'unctionality ol'
an astronomicaltime clock in accordance with $l10.9; meets the Installation Certification requirements in $130.4; meets the
requirements for an EMCS in $ I 30.5; does not have an override or bypass switch that allows the luminaire to be always ON: and.
is programmed to automatically turn the outdoor liehtine OFF during daylieht hours.
I
I
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances. balconies, and porches: and outdoor
lighting for residentialparking lots and residential carports with less than eight vehicles per site shall comply with one of the
following requirements:
i. Shall comply with $ 150.0(k)9A; or
ii. Shall comply with the applicable requirements in !il10.9, $130.0, $130.2, $130.4, $140.7 and $141.0.
$ r s0.0(k)eB
For low-rise residential buildings with fbur or more dwelling units, outdoor lighting not regulated by $150.0(k)98 or 150.0(k)9D
shallcomply with the applicable requirements in $110.9, $130.0, li130.2, $130.4, $140.7 and $141.0.$ 1s0.0(k)eC:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in $l10.9, $130.0, $130.2, $130.4, $140.7 and $141.0.$ 150.0(k)9D
Internally illuminated address signs shallcomply with $140.8; or shallconsume no more than 5 watts of power as determined
according to $ 130.0(c).
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements fbr
nonresidential garases in (il10.9. li130.0. $130.1. $130.4. li140.6, and lil4l.0.$ r 50.0(k) ll
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less ol
$150.0(k)l2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high eflicacy luminaires or
controlled bv an occuDant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
i. Comply with the applicable requirements in $l10.9, $130.0, $130.1, $140.6 and $141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shallbe capable of turning the light fully On and Off from alldesigned paths ol'
ingress and egress.
$rs0.0(k)r2B
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application tbr a
tentativesubdivisionmapfortheresidenceshasbeendeemedcomplete,bytheenforcementagency,onorafterJanuary 1,2014.
shallcomply with the requirements of $l10.10(b) through $l10.10(e).
$ I l0.l 0(a) I
| $ I 10.l0(a)2: Low-rise multi-family buildings shall comply with the requirements of $ I 10.10(b) through ti I 10. l0(d)
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24,Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi'family buildings the solar zone shall be located on the roof or overhang of'the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
buildine proiect and have a total area no less than l5 percent of the total roof area of the buildine excluding any skylight area.
$l 10.10(b)2: All sections ofthe solar zone located on steep-sloped roofs shall be oriented between I l0 degrees and 270 degrees oftrue north
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.$l10.10(b)3A
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
the distance, measured in the horizontal plane, of the height diflerence between the highest point of the obstruction and the
horizontal proiection of the nearest point of the solar zone, measured in the vertical plane.
lil10.r0(b)38
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.$l r0.10(b)4:
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water-heating
system.
$l10.10(c)
A copy of the construction documents or a comparable document indicating the information from {i I 10. l0(b) through $ I 10. l0(c)
shall be provided to the occupant.$r 10.10(d)
$ I 10.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker lor a
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input fbeder location ur
main circuit location, and permanently nrarked as "For Future Solar Electric".
$l10.10(e)2:
t
o
$ l 50.0(k) l0:
$r r0.10(b)r:
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
[t/r. & Mrs. Swenson
Date
8t2t2016
System Name
HVAC 1
Floor Area
919
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1
Heating System
Output per System 51,000
Total Output (Btuh)51,000
Output (Btuh/sqft)55.5
Cooling System
Output per System 36,000
Total Output (Btuh)36,000
Total Output (Tons)3.0
Total Output (Btuh/sqft)39.2
Tota! Output (sqfUTon)306.3
Tota! Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
16,785 14,419TOTAL SYSTEM LOAD
236
0
0 0 0
236
0
0
CFM Sensible Latent CFM Sensible
COIL COOLING PEAK
704 16,313
0
COIL HTG. PEAK
334 14,084
168
168
0
0
0
Air System
CFM per System 1,200 HVAC EQUIPMENT SELECTION
Airflow (cfm)1,200
Airflow (cfm/sqft)1.31
Airflow (cfm/Ton)400.0
Outside Alr (%l 0.0 o/o
Outside Air (cfm/sqft)0.00
lNote, values above glven at ARI conditions
Carrier 58CVX070/24AC8736 28,298 1,957 5'1,000
28,298 1,957 51,000
Jan 1 AMAug 3 PMTIME OF SYSTEM PEAK
Total Adjusted System Output
(Adjusted for Peak Design conditions)
'-HeaTlNG SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
260F 72 0F 720F 112 0F
Heating Coil 112 0F
ROOM
72 0F 72 0F
LI
EIH
u H
Outside Air
0 cfm Supply Fan
1,200 cfm
E
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
I76 I 610F112 t780F
54/530FCooling Coil
43.6 Yo
76 I 610F
I [l 1
-
I il
76 t 62"F 54 / 53 0F
ROOM
a..- _
Outside Air
0 cfm Supply Fan
1,200 cfm
EneryyPro 6.7 by EnergySoft User Number: 6712 Ru n C ode : 201 6-08-0271 6 : 1 2 :28 Page 22 of 44
76 I 610F
ID:
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
]Mr. & Mrs. Swenson
Date
8t2t2016
System Name
HVAC 2
Floor Area
741
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1
Heating System
Output per System 51,000
Total Output (Btuh)51,000
Output (Btuh/sqft)68.8
Cooling System
Output per System 36,000
Total Output (Btuh)36,000
Total Output (Tons)3.0
Total Output (Btuh/sqft)48.6
Total Output (sqfUTon)247.0
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
787 12,6051 1,351TOTAL SYSTEM LOAD
0
CFM Sensible Latent CFM Sensible
COIL COOLING PEAK
78747111,032
0
160
0
0 00
0
160
COIL HTG. PEAK
291 12,313
146
146
0
0
0
Air System
CFM per System 1,200 HVAC EQUIPMENT SELECTION
Airflow (cfm)1,200
Airflow (cfm/sqft)1.62
Airflow (cfm/Ton)400.0
Outside Air (%)0.0 0/o
Outside Alr (cfm/sqft)0.00
lNote: vatues above glven at ARI conditions
Ca rrier 58CVX070/24AC 8736 28,429 1,748 51,000
28,429 1,748 5'1,000
Jan 1 AMAug 3 PMTIME OF SYSTEM PEAK
Total Adjusted System Output
(Adjusted for Peak Design conditions)
'HEATING SYSTEM PSVCHROMETRTS (Airstream Temperatures it rime of Heatins Peak)
26 0F 720F 72 0F 1120F
Heating Coil
ROOM
72 0F720F
HH
{
[lI
Outside Air
0 cfm Supply Fan
1,200 cfm
112 nl:
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
76 t 610F112 I 7B oF
54/53"FCooling Coil
43.1 o/o ROOM
76/61 0F76 I 610F
[l +
t_,
H itl
76t610F 54/530F
Outside Air
0 cfm Supply Fan
1,200 cfm
EnergyPro 6.7 by EnergySoft User Number: 6712 Ru n Code : 201 6-08-0271 6 :1 2 : 28 ID Page 23 of 44
Ell
HVAG SYSTEM HEATING AND COOLING LOADS SUMMARY
Date
81212016
Project Name
Itt4r. & Mrs. Swenson
Floor Area
2,610
System Name
HVAC3&4
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 2
Heating System
Output per System 89,000
Total Output (Btuh)178,000
Output (Btuh/sqft)68.2
Cooling System
Output per System 58,500
Total Output (Btuh)1 17,000
Total Output (Tons)9.8
Tota! Output (Btuh/sqft)44.8
Total Output (sqfUTon)267.7
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
2,774 30,96971,208TOTAL SYSTEM LOAD
428
0
0
CFM Sensible Latent CFM Sensible
COIL COOLING PEAK
2,77463,4843,069
0
919
0
00 0
5,887
919
COIL HTG. PEAK
787 35,999
0
428
-5,887
Air System
CFM per System 2,000 HVAC EQUIPMENT SELECTION
Airflow (cfm)4,000
Airflow (cfm/sqft)1.53
Airflow (cfm/Ton)410.3
Outside Air (%)0.0 %
Outside Air (cfm/sqft)0.00
I ttote: values above given at ARt conditions
Carrier 24 ABCT 60|5BCVX 1 1 0 90,467 10,432 178,000
90,467 10,432 178,000
Jan 1 AMAug 3 PMTIME OF SYSTEM PEAK
Total Adjusted System Output
(Adjusted for Peak Design conditions)
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
720F 1150F26 0F 73 0F
Heating Coil 'l 15 0F
ROOM
720F720F
L
E []
HttOutside Air
0 cfm Supply Fan
4,000 cfm
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112 t780F 76/630F
Cooling Coil
47.4 Yo ROOM
76/630F 76/63"F
tl il 1
U I
78 / 63.F 56 / 55 "F
Outside Air
0 cfm Supply Fan
4,000 cfm
57l550F
6
EnergyPro 6.7 by EnergySoft User Number: 6712 Run C ode : 201 6-08-02T1 6 : 1 2 : 28 tD.Page 24 of 44
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
)Vlr. & Mrs. Swenson
Date
8tzt2016
Floor Area
933
System Name
HVAC 4
ENGINEERING CHECKS SYSTEM LOAD
Number of Systems 1
Heating System
Output per System 71,000
Total Output (Btuh)71,000
Output (Btuh/sqft)76.1
Cooling System
Output per System 47,500
Total Output (Btuh)47,500
Total Output (Tons)4.0
Total Output (Btuh/sqft)50.9
Total Output (sqfUTon)235.7
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
17,83614,608TOTAL SYSTEM LOAD
207
0
0 0 0 0
0
205 207
992
0
0
CFM SensibleCFMSensibleLatent
COIL HTG. PEAK
395 17,422
COIL COOLING PEAK
99262114,197
0
205
0
Air System
CFM per System 1,600 HVAC EQUIPMENT SELECTION
Airflow (cfm)1,600
Airflow (cfm/sqft)1.71
Airflow (cfm/Ton)404.2
Outslde Air (%)0.0 %
Outside Air (cfm/sqft)0.00
I].loter values above given at ARt conditions
Carrier 5BCVX090/24AC8648 37,006 2,979 71,000
71,00037,006 2,979
Jan 1 AMAug 3 PMTIME OF SYSTEM PEAK
Total Adjusted System Output
(Adjusted for Peak Design conditions)
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26 0F 72"F 114 "F
Heating Coil 1130F
ROOM
72 0F 72 0F
I H
Outside Air
0 cfm Supply Fan
1,600 cfm
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolins Peak)
76 t 620F112 t780F
55/530FCooling Coil
44.0 0/o ROOM
76 t62.F76 I 620F
I
|t.l J
I H
76 t62.F 54 t53.F
Outside Air
0 cfm Supply Fan
1,600 cfm
EnergyPro 6.7 by EneryySoft User Number: 6712 Run Code : 201 6-08-02T1 6 :1 2 :28 ID:Page 25 of 44
720F
I
H Htt
a
EI
ZONE LOAD SUMMARY
8/2J2016
DateProject Name
Mr. & Mrs. Swenson
Floor Area
919
System Name
HVAC 1
ZONE LOAD SUMMARY
COOLING PEAK HEATING PEAKZONAL SYSTEM
Peak Hr CFM Sensible Latent CFM SensibleSYSTEM NAME Mult.CFM Sensible Latent Heating OA CFMZONE NAME
Aug 3 PM 704 16,313 977 334 14,0841.0 0Master
16,313 977 14,0840000Aug 3 PMTOTALS
26 of 44de:201 6:12:28User Number: 67126.7
LOCK
IDE,
ZONE LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson 8/42U6
Date
System Name
HVAC 2
Floor Area
741
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult.CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible
Guest 1 1.0 0 Aug 3 PM 233 5,468 404 135 5,688
Office/Utility 1.0 0 Aug 3 PM 238 5,564 384 157 6,624
12,313TOTALS000011,032 787
LOCK L
RunCode:201 6:12:28 27 of 446.7 b User Number: 6712 ID
Aug 3 PM
o
ZONE LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson 8/2J2016
Date
Floor Area
2,610
System Name
HVAC3&4
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult.CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible
Living Area 1.0 0 Aug 3 PM 3,069 63,484 2,774 787 3A999
0 0 0 0 Aug 3 PM 63,484 2,774 35,999TOTALS
BLOCK
28 of 446.7 b User Number: 6712 IDE,2016-08-02T16:1
o o o
ZONE LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
System Name
HVAC 4
Floor Area
933
ZONE LOAD SUMMARY
ZONAL SYSTEM COOLING PEAK HEATING PEAK
ZONE NAME SYSTEM NAME Mult.CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible
Roark & S/oan 1.0 0 Aug 3 PM 621 14,197 992 395 17,422
TOTALS 0 0 0 0 Aug 3 PM 14,197 992 17,422
E 6.7 by EnergySoft User Number: 6712 RunCode:20 6:12:28 ID 29 of 44
(BLOCK LOAD)
u ^
o
o
ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson 8/2/2016
Date
System Name
HVAC 1
Floor Area
919
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult.CFM Sensible Latent CFIU Sensible Latent CFIU Sensible
Master Master Zone 1 704 16,313 977 704 16,313 977 334 14,084
'Total includes ventilation load for zonal systems.
PAGE TOTAL
TOTAL -
Paqe 30 of 44IDEneruyPrc 6.7 by EnergySoft User Number: 6712 RunCode: 2016-08-02T16:12:28
o
ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson 8/2/2016
Date
System Name
HVAC 2
Floor Area
741
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult.CFM Sensible Latent CFIVI Sensible Latent CFM Sensible
Guest 1 Guesf I Zone 1 233 5,468 404 233 5,468 404 135 5,688
Office/Utility Office/Utility Zone 1 238 5,564 384 238 5,564 384 1s7 6,624
'Total includes ventilation load for zonal systems
PAGE TOTAL
TOTAL -
Paqe 31 of 44ID:EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-08-02T16:12:28
ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
System Name
HVAC3&4
Floor Area
2,610
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
CFM SensibleZone Name Room Name Mult CFM Sensible Latent CFM Sensible Latent
Living Area Living Zone 1 3,069 63,484 2,774 3,069 63,484 2,774 787 35,999
PAGE TOTAL
TOTAL -
* Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number: 6712 Ru n Code : 201 6-08-02T1 6 : 1 2 :28 ID:Pase 32 of 44
o
o
o
o
ROOM LOAD SUMMARY
Project Name
Mr. & Mrs. Swe nson
Date
8/2/2016
System Name
HVAC 4
Floor Area
933
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG, PEAK
Zone Name SensibleRoom Name Mult CFM Sensible Latent CFM Sensible Latent CFM
Roark & S/oan Roark & S/oan Bdrms 1 621 14,197 992 621 14,197 992 395 17,422
'Total includes ventilation load for zonal systems.
Paqe 33 of 44ID:EnerqvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode: 2016-08-02716:12:28
o PAGE TOTAL
TOTAL -
o
o
ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Master Zone
919.0 ft'
72 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT OF Btu/hr
919.0
417.4
176.2
104.4
perim = 140.0
650.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.4000
0.4000
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46
46
46
46
46
0
Items shown with an asterisk (-) denote conduction through an interior surface to another room Page Total
lnfittration:I 1.00 x 1.064 x 919 9.00 0.266 46
Schedule
Fraction
Air Sensible ACHArea
x
Ceiling Height
x /60] x
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 14,084
6.7 b IDUser Number: 6712 RunCode: 201&08-02T16:12:28 of 44
o
ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Guest 1 Zone
380.0 ft,
72 0F
Time ol Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction AT o
FAreaU-Value Btu/hr
380.0
145.7
64.0
5.3
perim = 82.0
565.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.4000
0.4000
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46
46
46
46
46
0
Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total
tnfiltration:I 1.00 x x 0.266 /60] x 46
Schedule
Fraction
Air S ACH
1.064 9.00x
ng Height
x
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 5,688
12 ID:2016-08-02T16:12:28
o
380
e
o
ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Office/Utility Zone
361.0 ft'
72 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT OF Btu/hr
361.0
400.0
45.0
perim = 96.0
440.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.4800
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46
46
46
46
0
Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total
tnfiltration:I x x 361 0.266 /60] x 46
e
Fraction
1.0641.00 9.00
Area
x
Height
x
ACH AT
TOTAL HOURLY HEAT LOSS FOR ROOM 6,624
6.7 b IDUserNumber:6712 RunCode:2016-08-02T16:12:28 44
o
R-38 Roof(R. 38.2x 1 4. 1 6)432
R-21 Wall (W.21.2x6.1 6)1,270
DualMetalTinted HS 994
Slab-On-Grade 3,224
*R-0 lnteiorWall 0
5,919
706
3
ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Living Zone
2,610.0 ftz
72 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT OF Btu/hr
2,610.0
877.4
694.6
326.0
30.0
perim = 162.0
1,635.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.4000
0.4000
0.5600
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46
46
46
46
46
46
0
Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total
lnliltration:I 1.00 x 1.064 x 2,610 46
Schedule
Fraction
Air Sensible
9.00 0.266
Area
x
c
x /60] x
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 35,999
6.7 b 37 of 44User Number: 6712 Run
o
O
ROOM HEATING PEAK LOADS
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
Indoor Dry Bulb Temperature
Roark & S/oan Bdrms
933.0 ft'
72 0F
Time of Peak
Outdoor Dry Bulb Temperature
Jan 1 AM
26 0F
Conduction Area U-Value AT o
F Btu/hr
933.0
939.7
140.4
90.0
42.9
perim = 188.0
640.0
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.4000
0.4000
0.4800
0.7300
0.3560
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
46
46
46
46
46
46
0
Items shown with an asterisk (") denote conduction through an interior surface to another room Page Total
lnfiltration:I x 1.064 x 933 x /60I 46
Air Sensible Area Ceiling
1.00 9.00 0.266x x
AT
TOTAL HOURLY HEAT LOSS FOR ROOM 17,422
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode:2016-08-02716:12:28 ID:Page 38 of 44
o
Fraction
o
o
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Master Zone
919.0 ft'
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(W
(N)
(E)
(N)
919.0
83.6
291.8
42.0
650.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
77.0
31.0
39.6
45.0
0.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(E)
(E)
(E)
(N)
0.0
0.0
21.9
0.0
x
x
x
x
x
x
x
x
x
23.8
23.8
23.8
22.8
+
+
+
+
+
+
+
+
+
100.8
7.8
45.7
104.4
x
x
x
x
x
x
x
x
x
44.9
44.9
44.9
22.8
Page Total
lnternal Gain Btu/hr
2.8
919
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x 0.88 x 37.90 x 36
Air CFM ELA AT
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,313
Latent Gain Btu/hr
2.8 Occupants X 155
lnfiltration:4,771 x 0.88 x 37.90 x 0.00344
Air Sensible CFM ELA AW
Btuh/occ.
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 427
EnersvPto 6.7 bv EnersvSoft User Number: 6712 RunCode:2016-08-02T16:12:28 lD Paqe 39 of 44
o
R-38 Roof(R. 38.2x1 4. 1 6)1,840
179R-21 Wall (W.21.2x6.1 6)
R-21 Wall (W.21.2x6.1 6)796
R-21 Watl (W.21.2x6.16)130
*R-0lnteiorWall 0
2,
12 4,530
13 351
14 2,575
15 2,385
1
1
549
o
o
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Guest 1 Zone
380.0 ft,
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
ue Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(w
(E)
380.0
145.7
565.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.3560
x
x
x
x
x
x
x
x
x
77.0
44.0
0.0
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(E)
(E)
18.4
5.3
x
x
x
x
x
x
x
x
x
22.8
23.8
+
+
+
+
+
+
+
+
+
45.6
0.0
x
x
x
x
x
x
x
x
x
49.6
52.3
Page Total
!nternal Gain Btu/hr
%Equipment I
1.1
380
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x 0.88 x 15.67 x 36
r e CFM ELA AT
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,468
Btu/hr
1.1 Occupants X 155
lnfiltration:x 0.88 x 15.67 x 0.00344
Air ible CFM ELA AW
4,771
Btuh/occ.
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 177
EnerqvPro 6.7 bv EnerqvSoft User Number: 6712 RunCode:2016-08-02716:12:28 lD Paqe 40 of 44
o
Latent Gain
O..r'rn,,
-l
o
o
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swe nson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Office/Utility Zone
361.0 ft',
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
7B OF
34 0F
ue Surfaces Orientation Area U-Factor CLTDl Btu/hr
(N)
(E)
361.0
207.0
193.0
440.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
77.0
31.0
44.0
0.0
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(E)
(E)
0.0
0.0
x
x
x
x
x
x
x
x
x
25.4
25.4
+
+
+
+
+
+
+
+
+
22.5
22.5
x
x
x
x
x
x
x
x
x
53.9
53.9
Page Total
Btu/hr
1.1
361
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x 0.88 X 14.89 x 36
I CFM ELA AT
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,564
Latent Gain Btu/hr
1.1 Occupants X 155
lnfiltration:x 0.88 x 14.89 x 0.00344
Air ible CFM ELA AW
4,771
Btuh/occ.
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 168
EnergvPro 6.7 bv EnergvSoft User Number: 6712 RunCode:2016-08-02716:12:28 lD:Pase 41 of 44
o
(W
lnternal Gain
Oaarornr,
-l=Or,Or"n, --l
M
o
o
RESIDENTIAL ROOM GOOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Living Zone
2,610.0 ft2
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 OF
34 0F
o ue Surfaces Orientation Area U-Factor CLTDl Btu/hr
(W
(N)
(s)
(sw
(NE)
(W
(N)
2,610.0
20.9
346.0
132.7
211.6
137.0
29.2
1,635.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
Page Total 7,822
Items shown Wth an asterisk (.) denote conduction through an interior surface to another room1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(N)
(s/
(sw
(NE)
(w
(sw
(N)
(N)
(N)
0.0
326.0
55.5
0.0
95.9
10.6
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
23.8
22.8
23.8
23.8
23.8
23.8
26.5
23.8
23.8
+
+
+
+
+
+
+
+
+
x
x
x
x
x
x
x
x
x
Page Tota!
lnternal Gain Btu/hr
7.8
2,610
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:x 0.88 x 107.65 x 36
Air ble CFM ELA AT
77.0
31.0
40.2
53.0
34.0
55.0
45.0
0.0
44.1
0.0
0.0
28.4
321.1
24.2
30.0
29.0
29.0
23.8
33.0
35.7
71.3
67.1
54.9
53.1
53.1
1.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 63,484
7.8 155
4,771 0.88 0.00344107.65
Latent Gain Btu/hr
Occuoants Btuh/occ.
lnfiltration:
Air Sensible CFM
x x x
AW
Occupants X
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 ,214
EnergvPro 6.7 bv EneruvSoft User Number: 6712 RunCode:201&08-02716:12:28 lD:Pase 42 of 44
R-38 Roof(R.38.2x1 4. 1 6)
R-21 Wall (W.21.2x6.1 6)
R-21 Wall (W.21.2x6.1 6)
R-21 Wall (W.21.2x6.1 6)
R-21 Watl (W.21.2x6.1 6)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)91
*R-0 lnterior Wall
7 1,051
16 7,447
18 1,323
17 1,014
2 25,189
22 1,875
A 1,647
I 1,541
1 1,541
1,9
67.1
a
o
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM !NFORMATION DESIGN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Living Zone
2,610.0 ft,
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 OF
34 0F
Surfaces Orientation Area U-Factor CLTDl Btu/hr
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Page Total 0
Items shown with an asterisk (.) denote conduction through an interior surface to another room.1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(N)
(N)
(N)
0.0
0.0
0.0
x
x
x
x
x
x
x
x
x
23.8
23.8
23.8
+
+
+
+
+
+
+
+
+
39.2
13.1
4.5
x
x
x
x
x
x
x
x
x
53.1
53.1
53.1
Page Total
Internal Gain Btu/hr
7.8
2,610
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
Wsqft
lnfiltration:x x x 36
Air FM AT
0.88 107.651.064
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 63,484
7.8 155
0.88 107.654,771
Latent Gain Btu/hr
Btuh/occ
lnfiltration:
CFM
x x
Air ELA AW
x
Occupants X
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 ,214
Paqe 43 of 44EnerqvPrc 6.7 bv EnerqvSoft User Number: 6712 RunCode:2016-08-02T16:12:28 lD
0.00344
Occupants
a
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Mr. & Mrs. Swenson
Date
8/2/2016
ROOM INFORMATION DES!GN CONDITIONS
Room Name
Floor Area
lndoor Dry Bulb Temperature
Roark & S/oan Bdrms
933.0 ft'
76 0F
Outdoor Dry Bulb Temperature
Outdoor Wet Bulb Temperature
Outdoor Daily Range:
1120F
78 0F
34 0F
Surfaces Orientation Area U-Factor CLTD1 Btu/hr
(W
(NE)
(sE)
(sw
(NW
933.0
375.0
68.0
319.6
177.1
640.0
x
x
x
x
x
x
x
x
x
0.0260
0.0690
0.0690
0.0690
0.0690
0.3560
x
x
x
x
x
x
x
x
x
56.0
30.3
29.3
31.7
29.3
0.0
Page Total
Items shown with an asterisk (.) denote conduction through an interior surface to another room.1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration Orientation Area GLF
Unshaded
Area GLF Btu/hr
(NE)
(sw
(sw
(NW
(NW
1.1
0.0
85.4
0.0
0.0
x
x
x
x
x
x
x
x
x
19.9
19.9
19.9
19.1
21.5
+
+
+
+
+
+
+
+
+
18.9
35.0
0.0
90.0
42.9
33.1
28.1
28.1
28.8
31.8
Page Total
lnternal Gain Btu/hr
2.8
933
Occupants
Floor Area
x
x
245
0.50
Btuh/occ.
w/sqft
lnfiltration:1.064 x 0.88 x 38.48 x 36
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,197
2.8 155
4,771 0.88 38.48 0.00344
Latent Gain Btu/hr
Btuh/occ.
lnfiltration:
Air Sensible
Occupants
x x
CFM ELA AW
x
Occupants X
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 434
Pase 44 of 44EnergvPto 6.7 by EnergySoft User Number: 6712 RunCode:2016-08-02716:12:28 lD:
a
R-38 Roof(R. 38.2x1 4. 1 6)1,358
R-21 Wall (W.21.2x6.1 6)785
R-21 Watl (W.21.2x6.1 6)138
R-21 Wall (W.21.2x6.16)698
R-21 Wall (W.21.2x6.1 6)
*R-0 lnteriorWall
24 x
x
x
x
x
x
x
x
x
647
19 982
20 1,697
21 2,590
23 1,363
1
1
I