Loading...
BSOL2023-1071BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 11/01/2023 ISSUED DATE: 01/03/2024 Permit Type: Permit Number: Property Address: APN: Legal Description Property Zoning: Valuation: Solar 57435 SEMINOLE DR BSOL2023-1071 762350024 $47,500.00 Owner:KEVIN DANKO 57435 SEMINOLE DR DR, LA QUINTA, CA 92253 Applicant:Desiree Manard 18217 Harley John Road, Riverside, CA 92504 Contractor:Desiree Manard / 1064475 18217 Harley John Road, Riverside, CA 92504 Declaration / Acknowledgement PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER-BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors’ State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors’ State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors’ State License Law does not apply to an owner of property who, through employees’ or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors’ State License Law. As an Owner-Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner-builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS’ COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS’ COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY’S FEES. 1) Has and will maintain a certificate of consent to self-insure for workers’ compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers’ compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California, and agree that, if should become subject to the workers’ compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 1/3/24 11:12 pm Page 1 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2023-1071 57435 SEMINOLE DR BUILDING PERMIT 19.04kWDC ROOF MOUNTED PV SYSTEM - (47) 405W HANWHA Q. PEAK DUO BLK ML-G10 MODULES, (47) ENPHASE IQ8A-72-2-US MICROINVERTERS, (1) 200 AMP LOAD CENTER, (1) 100 AMP AC DISCONNECT, WITH DERATING OF MAIN SERVICE TO A 150 AMP OVERCURRENT DEVICE. 2022 CALIFORNIA ELECTRICAL CODES. Use of Permit Construction Details ResidentialPV System Type 19.04System Size (kW DC)5PV Strings (EA) 0PV Miscellaneous Equipment EA Valuation Details Type Group Sq Ft Value Financial Information Fee AmountFee Amount PaidInvoice No. INV-00003434 $8.00 Technology Enhancement Fee $8.00 $45.77 Solar (PV) More than 10kW $45.77 $6.88 Credit Card Convenience Fee $6.88 $45.75 Hourly Charge - City Building Staff $45.75 $1.90 Building Standards Administration $1.90 $115.94 Permit Issuance $115.94 $45.77 Solar (PV) More than 10kW PC $45.77 $12.00 Digital Archiving and Records Management Fee - OTC $12.00 $282.01 $282.01 Total for Invoice INV-00003434 Grand Total for Permit $282.01 $282.01 Workflow / Inspections Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 11/01/2023 14:10 11/01/2023 14:10 Submittal Document Verification v.1 Generic Action 11/01/2023 14:10 Plan Check v.1 11/01/2023 0:00 12/13/2023 4:40 Building Review (1 Day) v.1 Receive Submittal 11/01/2023 0:00 11/27/2023 9:42 Building Review (1 Day) v.2 Receive Submittal 11/30/2023 0:00 12/07/2023 9:42 Building Review (1 Day) v.3 Receive Submittal 12/11/2023 0:00 12/13/2023 4:40 Permit Issuance v.1 01/03/2024 13:58 01/03/2024 15:12 Verify Contractor info & Conditions have been met v.1 Generic Action 01/03/2024 13:58 Verify & Invoice Fees v.1 Generic Action 01/03/2024 13:58 Verify Fee Payment & Issue Permit v.1 Generic Action 01/03/2024 15:11 Print, Attach, and Email Building Permit v.1 Create Report 01/03/2024 15:11 01/03/2024 15:12 Solar Inspections v.1 Rough Electrical v.1 Inspection Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 Solar Final v.1 Inspection Printed: 1/3/24 11:12 pm Page 2 of 3 Permit Type: Permit Number: Property Address: Solar BSOL2023-1071 57435 SEMINOLE DR BUILDING PERMIT Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Inspections A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Certificate of Occupancy A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Service Utilities Printed: 1/3/24 11:12 pm Page 3 of 3 DESIGN & DEVELOPMENT D EPARTMENT 78-495 C ALLE T AMPICO L A Q UINTA , C ALIFORNIA 92253 (760) 777 -7 125 FAX (760) 777 -7011 Residential Plan Check Correction List (SOLAR) Page 1 of 3 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: 11/27/2023 STATUS: FIRST REVIEW PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 57435 SEMINOLE DESCRIPTION: PV SOLAR SYSTEM APPLICANT: DESIREE MANARD PLAN CHECK #: BSOL2023-1071 This submittal has been checked for compliance with the 2022 California Building Codes and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: 1- 1ST SUBMITTAL SOLAR PLAN 1 - CORRECTION LIST DO NOT accept any resubmittal unless ALL of the following items are included: 1- REVISED SOLAR PLAN 1- CORRECTION LIST w/responses INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red-marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall be wet-signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by Californi a Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 2 of 3 SECTION A - GENERAL 1) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer’s name and telephone number and wet-signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code '5536. Resubmittals will not be accepted with signatures missing. SECTION B – SOLAR I. General 1) No comments. II. Circuit Requirements 1) No comments. III. Disconnecting Means 1) No comments. IV. Wiring Methods 1) No comments. V. Grounding 1) No comments. VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1) Provide schedule with the location of all required markings and labels for the proposed photovoltaic system. (CEC §690) Please update signage sheet per 2002 California Electrical Code requirements. Some of the code references provided under placards are incorrect or outdated. See sheet PV-6, please check all labels. 2) A permanent plaque or directory denoting the location of all electric power source disconnecting means on or in the premises shall be installed at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable of being interconnected. The marking shall comply with 110.21(B), (CEC §705.10). Please show the location of the IID required AC disconnect on the site equipment placard. See sheet PV-6, lower right-hand corner. SECTION C - FIRE 1) No comments. SECTION D - STRUCTURAL 1) No comments. SECTION E - MISCELLANEOUS COMMENTS 1) No comments. Residential Plan Check Correction List Page 3 of 3 END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. DESIGN & DEVELOPMENT D EPARTMENT 78-495 C ALLE T AMPICO L A Q UINTA , C ALIFORNIA 92253 (760) 777 -7 125 FAX (760) 777 -7011 Residential Plan Check Correction List (SOLAR) Page 1 of 2 RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR) DATE: 12/7/2023 STATUS: SECOND REVIEW PLAN CHECKED BY: DUANE CLAYTON TELEPHONE NUMBER: 760-777-7084 ADDRESS: 57435 SEMINOLE DESCRIPTION: PV SOLAR SYSTEM APPLICANT: DESIREE MANARD PLAN CHECK #: BSOL2023-1071 This submittal has been checked for compliance with the 2022 California Building Codes and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for correction: 1- 2ND SUBMITTAL SOLAR PLAN 1 - CORRECTION LIST DO NOT accept any resubmittal unless ALL of the following items are included: 1- REVISED SOLAR PLAN 1- CORRECTION LIST w/responses INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, “Sheet A-3,” or, “Handrails shall be per CBC Section 1003,” are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, “Added note 16 on sheet A-3” are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red-marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer’s name and telephone number and shall be wet-signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by Californi a Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List (SOLAR) Page 2 of 2 SECTION A - GENERAL 1) PC-1: Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer’s name and telephone number and wet-signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code '5536. Resubmittals will not be accepted with signatures missing. PC-2: Comment remains – Please provide designer of record signatures on all plan sheets – PV-0, PV-1, PV-2, PV-3, PV- 4, PV-5, and PV-6. SECTION B – SOLAR I. General 1) No comments. II. Circuit Requirements 1) No comments. III. Disconnecting Means 1) No comments. IV. Wiring Methods 1) No comments. V. Grounding 1) No comments. VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts 1) No comments. SECTION C - FIRE 1) No comments. SECTION D - STRUCTURAL 1) No comments. SECTION E - MISCELLANEOUS COMMENTS 1) No comments. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Desiree Manard <desiree@tbdsolar.com> Fwd: 57435 Seminole Dr, LA Quinta CA - IID PV SOLAR INSPECTION 1 message Marianne The Big Deal Solar Inc. Installation <installer@tbdsolar.com>Wed, Oct 25, 2023 at 10:15 AM To: Desiree Manard <desiree@tbdsolar.com>, Bonnie Rodriguez <bonnie@tbdsolar.com> Good Morning, Received this from IID yesterday afternoon, please advise. V/R Marianne DeLuna Project Manager/Skillbridge Coordinator/USMC Veteran The Big Deal Solar Inc dba Desert Clean Energy 18217 Harley John Road Riverside, CA 92504 www.linkedin.com/in/marianna-deluna ---------- Forwarded message --------- From: Alvarez, Sergio O <soalvarez@iid.com> Date: Tue, Oct 24, 2023 at 3:30 PM Subject: 57435 Seminole Dr, LA Quinta CA - IID PV SOLAR INSPECTION To: installer@tbdsolar.com <installer@tbdsolar.com> Cc: Solar <Solar@iid.com>, Valdivia, Dania <dmvaldivia@iid.com> IID DG Site Inspection Contractor: The Big Deal Solar Inc Address: 57435 Seminole Dr, LA Quinta CA Service Type: UG Comment: Meter: 1B4B-238212 Current MSP 200 A/ MSB 200A Temporary Disconnect de-rate From one of the MSB from 200A to 150A After a solar inspection on 10/24/2023, Main Service Disconnect De-Rate, will require a temporary disconnect to be requested, no work can be performed prior to IID approval. Utility DG AC disconnect location shall be placed on North East corner of dwelling North wall. IID Requirements: Main Service Panel working space requires a minimum of 36in working space to be kept clear and unobstructed in front of meter. Minimum clearance from gas meter should be 36in Minimum clearance from plumbing fixtures should be 18in Main Service Panel Breaker De-rate, to perform this de-rate you will need to request a temporary disconnect to IID. Temporary disconnect need to be requested 2-3 days in advance for approval (approvals depend on availability). IID interconnection fees be covered prior to request temporary disconnect IID required 24-hour cancellation notice. Failure to do so will result in no show fees. Authority Having Jurisdiction (AHJ) inspection is required prior to IID reconnecting the power. Utility DC AC safety disconnect shall be installed as stated in picture above within 5ft and plain sight of meter panel, readily accessible. 1. Minimum clearance between Utility DG AC disconnect and meter service panel is 12in (Detail-A1). 2. Disconnect means shall clear the main service panel doors swing with a minimum 6in clearance (Detail-A1). Detail A1 Warning Labels and Signs Note: Marking/labels for equipment location and identification shall be placed in accordance with IID standard(s)/requirement(s), NEC, code, regulation, etc. Electrical service and installation shall comply with codes, regulation, laws, AHJ, IID standards, etc. This inspection does not constitute a final inspection or approval to turn on your Solar System. Sergio O. Alvarez E nergy Eficiency Technician 81600 Ave. 58, La Quinta, CA Desk (760) 398-5812 | Cell: (760) 925-7690 email: soalvarez@iid.com COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 57435 SEMINOLE DR, LA QUINTA, CA 92253 USA SHEET NAME SHEET NUMBER PV-0 PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A AP N # 7 6 2 3 5 0 0 2 4 UT I L I T Y : I I D AH J : C I T Y O F L A Q U I N T A REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SYSTEM SUMMARY: ROOF TYPE: - S-TILE ROOF FRAME: - 2"X6" RAFTERS @24" O.C. STORY: - ONE STORY SNOW LOAD : - 0 PSF WIND SPEED :- 97 MPH WIND EXPOSURE:- C EXPOSURE CATEGORY:- II DESIGN CRITERIA: PROJECT SITE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 ARRAY LOCATIONS(N) 47 - HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES (N) 47 - ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO-INVERTERS (N) 02 - JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (N) 150A MAIN BREAKER (N) 100A NON-FUSED AC DISCONNECT, [SQUARE D DU323RB], 240 VAC (N) 200A SOLAR LOAD CENTER GENERAL NOTES 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2022 CEC. 3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. 7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. 10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 12.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING TO CEC 690.35(F). 13.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [ CEC 690.35(G)]. 14.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [ CEC 690.4(C)] 15.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 16.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 17.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. 18.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH CEC 690.12 19.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [ CEC 690.13(A)] 20.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 21.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 10.26(A)(3). 22.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 23. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA GREEN BUILDING CODE (CGBC) 2022 CALIFORNIA HISTORICAL BUILDING CODE (CHBC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ENERGY CODE (CEC) GOVERNING CODES: PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 ELECTRICAL LINE DIAGRAM PV-5 ELECTRICAL CALCULATION PV-5.1 LOAD CALCULATION PV-6 PLACARDS & WARNING LABELS PV-7+ EQUIPMENT SPEC SHEETS SHEET INDEX EXISTING BUILDING INFORMATION: ZONE :- SINGLE FAMILY RESIDENTIAL ZONE TYPE :- RESIDENTIAL SINGLE FAMILY OCCUPANCY GROUP :- R3 CONSTRUCTION TYPE :- V-B YEAR BUILT: 2004 PHONE NO:- 951-235-2789 47 MODULES ROOF MOUNTED - 19.04 kWDC, 16.40 kWAC DERATE: (E) 200A MAIN BREAKER TO BE DERATED TO (N) 150A TO ALLOW BACKFEED OF 90A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 BSOL2023-1071 - 57435 SEMINOLE DRIVE 19.04kWDC ROOF MOUNTED PV SYSTEM - (47) 405W HANWHA Q. PEAK DUO BLK ML-G10 MODULES, (47) ENPHASE IQ8A-72-2-US MICROINVERTERS, (1) 200 AMP LOADE CENTER, (1) 100 AMP AC DISCONNECT, WITH DERATING OF MAIN SERVICE TO A 150 AMP OVERCURRENT DEVICE. 2022 CALIFORNIA ELECTRICAL CODES. 12/13/2023 MSPUM ACD SLC JB ~ 1 1 0 . 6 9 ' ~14 6 . 0 7 ' ~145. 7 6 ' ~ 6 1 . 0 5 ' 10'- 1 0 " 4 4 ' - 1 0 " 21'- 1 1 " 8 ' - 4 " JB MSPUM ACD SLC SITE PLAN WITH ROOF PLAN SHEET NAME SHEET NUMBER PV-1 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SITE PLAN WITH ROOF PLAN 1 SCALE: 1/16" = 1'-0" ·PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 47 MODULES MODULE TYPE = HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES MODULE WEIGHT = 48.4 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.29 PSF ROOF ACCESS POINT: SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. LEGEND UM - UTILITY METER MSP - MAIN SERVICE PANEL -JUNCTION BOXJB SLC - SOLAR LOAD CENTER ACD -AC DISCONNECT ENLARGE VIEW 1 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) (N) JUNCTION BOX (TYP.) EXI S T I N G DRI V E W A Y PROP E R T Y L I N E P R O P E R T Y L I N E PRO P E R T Y L I N E P R O P E R T Y L I N E S E M I N O L E D R ONE - S T O R Y HOU S E POOL ROOF ACCESS POINT (E) FENCE (E) TREES (TYP.) (E) GATE ROOF #1 (15) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #2 (11) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #3 (12) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #4 (02) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #5 (04) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #6 (03) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ENLARGE VIEW PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 &6/%-C46 1064475 (951) 901-0653 RYAN MF3+ERSON 3E  LIMONITE A9E -8R83A 9ALLEY &A    SOLAR#MF3E*RO83 CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 MSPUM ACD SLC JB JB SHEET NAME SHEET NUMBER PV-2 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 47 MODULES MODULE TYPE = HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULE WEIGHT = 48.4 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.29 PSF LEGEND VENT, ATTIC FAN (ROOF OBSTRUCTION) CHIMNEY ROOF ATTACHMENT RAFTERS JUNCTION BOXJB MSP MAIN SERVICE PANEL FIRE PATHWAY IRONRIDGE XR-10 RAIL UTILITY METERUM SCALE: 1/16" = 1'-0" ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO INVERTER SOLAR LOAD CENTERSLC 3' - 0 " 36" FIRE PATHWAY (47) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES (47) ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO INVERTER (02) BRANCHES OF 10 MODULES & (03) BRANCHES OF 09 MODULES CONNECTED IN PARALLEL 18 " 18" FIRE PATHWAY ARRAY AREA & ROOF AREA CALC'S ADU AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 992.68 4604.62 21.56% AC DISCONNECTACD BILL OF MATERIALS RAILS 24 IRONRIDGE XR-10 RAIL 168" DARK SPLICE 06 SPLICE MODULE CLAMPS 64 MODULE CLAMPS END CLAMPS 60 END CLAMPS ATTACHMENTS 89 UNIRAC TILE HOOK ATTACHMENTS GROUNDING LUG 15 GROUND LUG (N) 47 - ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO-INVERTERS BRANCH 3 (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 15 316.81 768.24 41.24 #2 11 232.33 438.25 53.01 #3 12 253.45 639.15 39.65 #4 02 42.24 142.45 29.65 #5 04 84.48 209.77 40.27 #6 03 63.36 1189.92 5.32 ROOF DESCRIPTION ROOF TYPE S-TILE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 17°138° 2"x6" 24" O.C. #2 17° 138° 2"x6" 24" O.C. #3 17° 228° 2"x6" 24" O.C. #4 17°228° 2"x6"24" O.C. #5 17°138° 2"x6"24" O.C. #6 17°318° 2"x6"24" O.C. CIRCUIT LEGENDS CIRCUIT #1 CIRCUIT #2 CIRCUIT #3 CIRCUIT #4 CIRCUIT #5 S E M I N O L E D R F R O N T Y A R D R E A R Y A R D NOTE ·PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. ·ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS. (E) S-TILE ROOF (TYP.) (N) (89) UNIRAC TILE HOOK ATTACHMENTS SPACED AT 72" O.C. (N) IRONRIDGE XR-10 RAIL (E) 2"X6" RAFTERS @ 24" O.C. (TYP.) 24" F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 36" FIRE PATH W A Y 48" F I R E P A T H W A Y 48" F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18" FIRE PATHWA Y 18" FIRE PATHWAY 18 " F I R E P A T H W A Y 18 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y ROOF #1 (15) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #2 (11) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #3 (12) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #4 (02) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES 18 " F I R E P A T H W A Y 18" FIRE PATHWA Y ROOF #5 (04) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES ROOF #6 (03) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES (N) JUNCTION BOX (TYP.) (E) UTILITY METER (E) MAIN SERVICE PANEL (N) 100A NON-FUSED AC DISCONNECT (N) 200A SOLAR LOAD CENTER BRANCH 2 BRANCH 1 BRANCH 4 BRANCH 5 ROO F # 1 TILT - 17 ° AZ I M U T H - 138 ° ROO F # 2 TILT - 17 ° AZ I M U T H - 138 ° ROO F # 3 TILT - 17 ° AZ I M U T H - 228 ° ROO F # 4 TILT - 17 ° AZ I M U T H - 228 ° ROO F # 5 TILT - 17 ° AZ I M U T H - 138 ° ROO F # 6 TILT - 17 ° AZ I M U T H - 318 ° PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 &SL%-C46 1064475 (951) 901-0653 5<$1 0F3+(5621 3(  /,021,7( $9( -8583$ 9$//(< &$    62/$5#0F3(*5283 CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 SHEET NAME SHEET NUMBER PV-3 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" ATTACHMENT DETAIL 6' OC FOOT SPACING 24" OC 3' - 1 0 " (N) UNIRAC TILE HOOK ROOF FRAMING MODULE ATTACHMENT DETAIL 2 ATTACHMENT DETAIL PV-3 ATTACHMENT DETAIL (ENLARGED VIEW) PV-3 SCALE: N.T.S (E) S-TILE ROOF AT CONCECTION, TYPICAL OF ALL: 1. REMOVE TILE AND LOCATE RAFTER. 2. ATTACH FLAT TILE HOOK PER MFG. INSTRUCTIONS. 3. REPLACE TILES AND NOTCH IF CECESSARY TO ENSURE PROPER FIT. PV MODULE END/MID CLAMP (2) 5/16 X 3" LAG BOLTS W/ EMBEDMENT DEPTH 2.5" NOTE: 1. 2" MINIMUM, 10" MAXIMUM BETWEEN ROOF DECK AND MODULES. (E) S-TILE ROOF (N) UNIRAC TILE HOOK (2) 5/16 X 3" LAG BOLTS W/ EMBEDMENT DEPTH 2.5" IRONRIDGE XR10 RAIL PV MODULE (N) IRONRIDGE XR10 RAIL 2 6 " PV-3 3 MOUNTING SURFACE SCALE: N.T.S 2"x6" RAF T E R S @ 24" OC 1 PV-3 PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 SHEET NAME SHEET NUMBER PV-4 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" ELECTRICAL LINE DIAGRAM ELECTRICAL LINE DIAGRAM SCALE: NTS1 SYSTEM SIZE:- 47 x 405W = 19.04 kWDC SYSTEM SIZE:- (47 x 349)/1000 = 16.40 kWAC BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 47 HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES MICRO INVERTER 47 ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO INVERTER INVERTER 1 200A SOLAR LOAD CENTER JUNCTION BOX 2 600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITION AC DISCONNECT 1 100A NON-FUSED AC DISCONNECT, [SQUARE D DU323RB], 240 VAC 120% RULE - CEC 705.12(B)(2)(3)(b) CALCULATION SHOULD BE 200A*1.20 = 240A-150A BACKFEED CAPACITY = 90A (N) 100A NON-FUSED AC DISCONNECT, [SQUARE D DU323RB], 240 VAC G N N L2 L1 L2 L1 (3) #2 AWG THWN (1) #6 AWG THWN CU GND 1-1/4" EMT CONDUIT SERVICE INFO UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: IID 240V (E) 200A (N) 150A NORTH-EAST UNDERGROUND L 150A EXISTING GROUNDING SYSTEM BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz (N) MAIN BREAKER 150A/2P, 240V 90A/2P (N) 90A/2P PV BREAKER (E) MAIN SERVICE PANEL, 200A RATED, 120/240V METER NO. : IID 75 272 831 (47) HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W) MODULES (47) ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICRO INVERTER (02) BRANCHES OF 10 MODULES & (03) BRANCHES OF 09 MODULES CONNECTED IN PARALLEL (47) ENPHASE ENERGY INC. IQ8A-72-2-US [240V] MICROINVERTERS (LOCATED UNDER EACH PANEL) G L1L1 L2L2 L1L1 L2L2 (5) # 12AWG Q CABLE (1) #6 BARE CU GND FREE AIR N G M*IQ-ENVOY BRANCH TERMINATOR E-TERM-10 (TYP.) 20A 20A 15A 20A L1 L2 L1 L2 L1 L2 L1 L2 20A (4) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN 09 MODULES IN BRANCH #3 10 MODULES IN BRANCH #4 (N) 200A SOLAR LOAD CENTER (N) #1 JUNCTION BOX L1 L2 L1 L2 09 MODULES IN BRANCH #5 20A G (N) #2 JUNCTION BOX (6) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN 10 MODULES IN BRANCH #1 09 MODULES IN BRANCH #2 DE-RATE: (E) 200A MAIN BREAKER TO BE DERATED TO (N) 150A TO ALLOW BACKFEED OF 90A PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 &6/%-C46 1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 SHEET NAME SHEET NUMBER PV-5 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" ELECTRICAL CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #HANWHA Q.CELLS Q.PEAK DUO BLK ML-G10 (405W)MODULES VMP 37.39 IMP 10.83 VOC 45.34 ISC 11.17 MODULE DIMENSION 74.0"L x 41.1"W x 1.25"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE ENERGY INC.IQ8PLUS-72-2-US [240V] MICRO INVERTERS NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.45A AMBIENT TEMPERATURE SPECS WEATHER STATION: PALM SPRINGS THERMAL AP RECORD LOW TEMP -5° AMBIENT TEMP (HIGH TEMP 2%)44° CONDUIT HEIGHT 0.9" ROOF TOP TEMP 44° CONDUCTOR TEMPERATURE RATE(ON ROOF)90° CONDUCTOR TEMPERATURE RATE(OFF ROOF)75° MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 ELECTRICAL CALCULATION SCALE: NTS1 ELECTRICAL NOTES AC CONDUCTOR AMPACITY CALCULATIONS: FROM #1 JUNCTION BOX TO SLC: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2): 7/8" RULE EXPECTED WIRE TEMP (°C): 44° TEMP CORRECTION PER TABLE 310.15(B)(1): 0.87 # OF CURRENT CARRYING CONDUCTORS: 6 CONDUIT FILL CORRECTION PER CEC 310.15(C)(1): 0.80 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 10 X 1.45A = 18.13A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC TABLE 310.15(B)(1) TEMP CORR. PER NEC TABLE 310.15(B)(1) X CONDUIT FILL CORR. PER CEC 310.15(C)(1) X CIRCUIT CONDUCTOR AMPACITY = 0.87 X 0.80 X 40 = 27.84A RESULT SHOULD BE GREATER THAN (18.13A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6. WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10. TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. AC CONDUCTOR AMPACITY CALCULATIONS: FROM COMBINER BOX 4 TO INTERCONNECTION:: # OF INVERTERS: 47 EXPECTED WIRE TEMP (°C): 44° TEMP CORRECTION PER TABLE 310.15(B)(1): 0.82 # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER CEC 310.15(C)(1): 1.0 CIRCUIT CONDUCTOR SIZE: 2 AWG CIRCUIT CONDUCTOR AMPACITY: 115A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(B): 1.25 X # MICRO-INVERTERS X MAX OUTPUT CURRENT = 1.25 X 1.45 X 47 = 85.19A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER CEC TABLE 310.16: TEMP CORR. PER CEC TABLE 310.15(B)(1) X CONDUIT FILL CORR. PER CEC 310.15(C)(1) X CIRCUIT CONDUCTOR AMPACITY = 0.82 X 1.0 X 115 = 94.3A RESULT SHOULD BE GREATER THAN (85.19A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY AC CONDUCTOR AMPACITY CALCULATIONS: FROM #2 JUNCTION BOX TO SLC: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2): 7/8" RULE EXPECTED WIRE TEMP (°C): 44° TEMP CORRECTION PER TABLE 310.15(B)(1): 0.87 # OF CURRENT CARRYING CONDUCTORS: 4 CONDUIT FILL CORRECTION PER CEC 310.15(C)(1): 0.80 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 10 X 1.45A = 18.13A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC TABLE 310.15(B)(1) TEMP CORR. PER NEC TABLE 310.15(B)(1) X CONDUIT FILL CORR. PER CEC 310.15(C)(1) X CIRCUIT CONDUCTOR AMPACITY = 0.87 X 0.80 X 40 = 27.84A RESULT SHOULD BE GREATER THAN (18.13A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 SHEET NAME SHEET NUMBER PV-5.1 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" LOAD CALCULATION LOAD CALCULATION SCALE: NTS1 PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 SHEET NAME SHEET NUMBER PV-6 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" WARNING LABELS & PLACARD WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: EMT/CONDUIT RACEWAYS (PER CODE: CEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER CEC 705.12(B)(3)(3) & CEC 690.59) ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: CEC 706.15 (C)(4) & CEC 690.13(B) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 68.15 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): 2022 CEC 690.56(C) 2022 CFC 1204.5.1 ! 4" 3" PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: CEC 690.13(B)) THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: CEC 705.12(B)(3)(3) LABEL LOCATION: MSP (PER CODE: CEC 705.12(D) & CEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING CEC 705.12 (B)(3)(2) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2) RAPID SHUTDOWN FOR SOLAR PV SYSTEM ! ! WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! LABEL LOCATION: INVERTER PER CODE: CEC 690.31(E) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION ! MULTIPLE POWER SOURCES LABEL LOCATION: PV DISCONNECT/BREAKER/ POINT OF CONNECTION (PER CODE: CEC 690.13(B) PHOTOVOLTAIC PV DISCONNECT PV ARRAY NON-FUSED DISCONNECT SOLAR LOAD CENTER MAIN SERVICE PANEL 57 4 3 5 S E M I N O L E D R BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2) APPLY TO: MAIN SERVICE PANEL REQ'D BY CEC 705.12 (D)(2) PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 &SL%-C46 1064475 (951) 901-0653 S<B1 NF3+(STP1 3( 51 /,NP1,7( B9( K8S83B 9B//(< DB 1 )1 77.1177 TP/BSANF3(HSP83 CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: ThLV LtHP hDV bHHn GLJLtDOO\ VLJnHG DnG VHDOHG on Dec 08, 2023 12/13/2023 SHEET NAME SHEET NUMBER PV-7 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-8 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-9 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-10 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-11 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-12 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: SHEET NAME SHEET NUMBER PV-13 REV DATEDESCRIPTION REVISIONS 10-17-2023DATE SHEET SIZE ANSI B 11" X 17" SPEC SHEETS PROJECT NAME KE V I N D A N K O 57 4 3 5 S E M I N O L E D R , L A Q U I N T A , C A 9 2 2 5 3 U S A UT I L I T Y : I I D AP N # 7 6 2 3 5 0 0 2 4 AH J : C I T Y O F L A Q U I N T A 18217 HARLEY JOHN RD RIVERSIDE CA 504 CSLB-C46 #1064475 (951) 901-0653 RYAN McPHERSON, P.E. 9240 LIMONITE AVE. JURUPA VALLEY, CA 92509 (909) 566-0066 SOLAR@McPE.GROUP CONTRACTOR: PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO THIS DESIGN ARE THE PROPERTY SOLELY OF McPHERSON ENGINEERING. PERMISSION FOR ANY COPIES OF SAID COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, IDEAS, DETAILS AND SPECIFICATIONS EITHER ORIGINALS OR COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION OF McPHERSON ENGINEERING. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE/SHE READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HERIN DESIREE MANARD: