BRES2017-0257 Geotechnical UpdateSladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 9220I (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (7I4) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778
July 21, 2015 Project No. 544-15165
15-07-292
Mr. Albert Davityan
8160 McGroarty Street
Sunland, California 91040
Project: Proposed Custom Residence
80-670 Via Montecito
Lot 70D - The Hideaway
La Quinta, California
Subject: Geotechnical Update
RECEIVE[
SEP 20 2017
CITY OF LA Ql1INTA
COMMUNITY OEVELOPMEF
Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated
September 22, 2000; File No. 07117-10, Report No. 00-09-772
Report of Testing and Observation During Rough Grading prepared by ESSW dated
August 28, 2002; File No. 07117-11, Report No. 01-07-718
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated October 12, 2003; Project No. 544-2199 Report No. 03-10-647
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence. The project site is located at 80-670
Via Montecito within the Hideaway Golf Club development in the City of La Quinta, California.
It is our understanding that the proposed residence will be a relatively lightweight wood -frame
structure supported by conventional shallow spread footings and concrete slabs on grade.
The subject lot was previously graded during the rough grading of the Hideaway project site and
was subsequently regraded. The rough grading included over -excavation of the native surface
soil along with the placement of engineered fill soil to construct the building pads. The regrading
included processing the surface soil along with minor cuts and fills to construct the individual
building pads to the current configurations. Some additional over -excavation was performed in
areas where the building envelopes were reconfigured. The most recent site grading is
summarized in the referenced Report of Testing and Observations During Rough Grading
prepared by Sladden Engineering along with the compaction test results.
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion that the
structural values included in the referenced grading report prepared by Sladden Engineering
remain applicable for the design and construction of the proposed residential structure
foundations.
Sladden Engineering
July 21, 2015 -2- Project No. 544-15165
15-07-292
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building falls within the previously established building
envelope. The building area should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface should be compacted to a minimum of
90 percent relative compaction is attained prior to fill placement. Any fill material should be
placed in thin lifts at near optimum moisture content and compacted to at least 90 percent
relative compaction.
The allowable bearing pressures recommended in the referenced grading report prepared by
Sladden Engineering remain applicable. Conventional shallow spread footings should be
bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent
grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be
at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations/slabs and passive
resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load
forces is recommended for use in design. Passive resistance may be estimated using an
equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the
frictional resistance should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is non -expansive and falls within the `very low" expansion category in
accordance with 2013 California Building Code (CBC) classification criteria. SIab thickness and
reinforcement should be determined by the structural engineer. We recommend a minimum
floor slab thickness of 4.0 inches and minimum reinforcement of H3 bars at 24 inches on center in
both directions. All slab reinforcement should be supported on concrete chairs to ensure that
reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10-mil Visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface can not be achieved by grading, consideration should be given to
placing a 1-inch thick leveling course of sand across the pad surface prior to placement of the
membrane.
Based on our field observations and understanding of local geologic conditions, the soil profile
type judged applicable to this site is Sr,, generally described as stiff soil. The following presents
additional coefficients and factors relevant to seismic mitigation for new construction based upon
the 2013 California Building Code (CBC).
Sladden Engineering
July 21, 2015 -3- Project No. 544-15165
15-07-292
The seismic design category for a structure may be determined in accordance with Section 1613
of the 2013 CBC or ASCE7. According to the 2013 CBC, Site Class D may be used to estimate
design seismic loading for the proposed structures. The 2013 CBC Seismic Design Parameters are
summarized below.
Risk Category (Table 1.5-1): I/II/11I
Site Class (Table 1613.3.2): D
Ss (Figure 1613.3.1): 1.500g
Si (Figure 1613.3.1): 0.681g
Fa (Table 1613.3.3(1)):1.0
Fv (Table 1613.5.3(2)): 1.5
Sms (Equation 16-37 ]Fa X Ss]): 1.500g
Sm1 (Equation 16-38 )Fv X S1]):1.003g
SDS (Equation 16-39 12/3 X Sms)):1.021g
SM (Equation 16-40 12/3 X Sm1)): 0.681g
Seismic Design Category: D
In addition, we have sampled the surface soil on the subject lot located at 80-670 Via Montecito
within the Hideaway development to determine the soluble sulfate content as it relates to
selecting appropriate concrete mix designs. Laboratory testing indicated soluble sulfate content
of 460 ppm (0.046 percent) that corresponds with the "negligible' exposure category in
accordance with Table 3 of ACI 318-08 Chapter 9. In accordance with ACI 318-08, special sulfate
resistant concrete mix designs should not be required for structural concrete on this project. Test
results are attached.
If you have questions regarding this letter or the referenced reports, please contact the
undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderso
Principal Engineer
SER/gvm
Copies: 4 / Addressee
G'..3.s9
�'- Ecp. v'i—VA6
Sladden Engineering
.5yL1-lS-��S-
�s-o7- z9 2-
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between the Investigation/reporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Quinta Geotechnical Report Checklist
Does the "Conclusions and Recommendatione section of the report address each of the
following criteria?
"Address" means:
(a) the criterion is considered significant and mitigation measure(s) no or,
(b) the criterion Is considered Insignificant and explicitly so stated.
es . No Criterion
' ❑ Foundation criteria based upon bearing capacity of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of expansive soils.
❑ Foundation criteria based upon bearing capacity. of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of liquefaction.
y ❑ Foundation criteria to mitigate the effects of seismically Induced differential
settlement.
` ❑ Foundation criteria to mitigate the effects of long-term differential settlement.
❑ Foundation criteria to mitigate the effects of varying soil strength.
U ❑ Foundation criteria to mitigate expected total and differential settlement.
Any "No" answers to the above checklist should be noted as specific required
corrections.
Sladden Engineering
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
Date: July 21, 2015
Account No.: 544-15165
Customer: Mr. Albert Davityan
Location: The Hideaway, 80-670 Via Montecito, Lot 70D, La Quinta
Sulfate Series
Analytical Report
Soluble Sulfates
per CA 417
ppm
•M
Soluble Chloride
per CA 422
ppm
150
Sulfate 544-15165 072115
TABLE'19ZA-2—REQUIREMENTS FOR SPECIAL EkPOSURECONDMO14S
IHIMUM 1 �
MAXIMUM
WATER:CDAEHTTTpUS ;
110R At.WE) AHD .
UGHf; 7EIGHT.
MATZRIAi3`' RATIO;AGGREGATE
GOHCREf
EXPOSURE COMMON
iAGr.AEGATE.00HCFt GHT•
AGG)'iEGATE COACRt_7'E •
. �
="',I .a
x O.p0GB9dor MAn
Conrretc intended to have low permeability whgn
exposed to water
050
,4,p00
Concrelc cxposcd to'f=zing and thawing in a moist
condition or to deicing chemicals
(01.45
For eorrosian protection for reinforced concrete
4,-560
exposed to chlorides from deicing phcmicals, salts or
brackish:%4atcr, or•sprayfrom fflese"sources
0.40
5000
TABLE 19-A-3--•REQUIREMEN.TS;FOI? CONCRETE
EXPOSED TO SULFATE-CONTAININO•SOI�UTIONS
NORMAL-WEJCj
UEIrifr
=A RMATE
AGGREGATE
.CONCRETE
Mmdmum'Weter-
WATEA-SOLUBLE Certxntl'Uous
11 Vorrnal-
elphtbnd
SULFATE M�teclatsaAetlo; 6y:.
((so i),I�N soft, - Wd' h4
SULFATE FACEHTAGEBr ��a!-WeJpfit�
?.Ughtwnlpht'
' -AaDrbgatz, .
-
SULFATE(SO4)IN
EXPOSURE WEIGHT , WATER AOCKpoln
ppm CEMERTTYPE
.Concrzie;,pslt
Concretes
Magligiblc 0.00-0.10 0-150 — _
x fk00b89'torNpa
ModerateZ, 0.1M20 150-1,500 II. LS '030•
d,000
S,),
Severe 0.20-2-00 1,500-10,000 - v 0.43
4500
Ycry severs Over 2.00 Over 10,000 V plus U.dS
4.500
Pozzolan3
to lower water-e-rnendtious materials ratio orhigbex strength may beJequicrd for low prrcpeabiliry orforproteetion '
against eorrosionof embMdr-d items or freaing
z and thawing [fable 19-A-2).
Seawatcr.
?Po—lan dmt has been dcttrmincd by test orservice record to improve sulfat
ecmcnG e resistance when used in concrete tan taisiing Type Y
2-264