Loading...
BRES2016-0345 Title 24I BUILDING ENERGY ANALYSIS REPORT PROJECT: WELLS MARVIN RESIDENCE addition 52880 EISENHOWER DR LA QUINTA, CA 92253 Project Designer: SOUTH WEST CONCEPTS INC. 78-115 CALLE ESTADO STE 2105 LA QUINTA, CA 92253 760 564-4707 Report Prepared by: Armando Chavez TITLE 24 OF THE DESERT SERVICES INC. 44890 Seeley Dr. La Quinta, CA 92253 760 278.1840 III MTZ MU U a"Nsa: Job Number: 2016-SWC-009-2R Date: 5/9/2017 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR ONSTRUCTION DATE The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. User Number: I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary Form MF-1 R Mandatory Measures Summary 2 3 12 14 EnergyPro 6. by EnergySoft Job Number: ID: 2016-SWC-009-2R User Number. 20648 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:10, Tue, May 09, 2017 Page 1 of 9 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.ribdx GENERAL INFORMATION 01 Project Name MARVIN RESIDENCE 02 Calculation Description Title 24 Analysis 03 Project Location 52880 EISENHOWER DR 04 City LA QUINTA 05 Standards Version Compliance 2015 06 Zlp Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4b (433) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.8 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftz) 1759 15 Number of Zones 1 16 Slab Area (ftz) 1759 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 1 Natural Gas Available No 20 Addition Slab Area (ft) N/A 21 Glazing Percentage (%) 19.3% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CECapproved HERS provider. 03 This building Incorporates one or more Special Features shown below This compliance analysis is raltd only for permit applications through December 31, 2016 —V w ENERGY USE SUMMARY 04 06 as 07 08 Energy Use (kTDVfft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.37 4.66 -1.29 -38.3% Space Cooling 82.05 73,92 8.13 9.9 % IAQ Ventilation 0.83 0.83 0.00 0.0 % Water Heating 32.95 34.56 1-1.61 1-4.9% Photovoltaic Offset -- 0.00 0.00 -- Compliance Energy Total 119.20 113.97 5.23 4.4% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016A33 Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: MARVIN RESIDENCE Calculation DatelTme: 10:10, Tue, May 09, 2017 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Raised heel truss • Cool roof • Window overhangs and/or fins • Exposed slab floor In conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field-venfed by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (Qll) • IAQ mechanical ventilation A. Cooling System Verifications: • Minimum Airflow • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: 41 None -13 - ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)• 1169.11 163.88 6.23 3.1% • includes calculated Appliances and Miscellaneous Energy Use (AMEUI BUILDING - FEATURES INFORMATION 01 02 03 04 06 06 07 Project Name Conditioned Floor Ate (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems MARVIN RESIDENCE 1759,E 1 0 1 0 1 Registration Number: ,+� Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.ribdx CF1R-PRF-01 Page 3 of 9 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 A Conditioned A-AC-1 1759 9 DHW Sys OPAQUESURFACES 01 02 03 04 05 06 07 09 Name Zone Construction AxImuth Orientation Gross Area (ft2) Window &Door Area (ft) Tift (deg) N-552 A R-21 Wall 0 Left 552 79 90 E-400 A R-21 Wall 0.1 90 Back 400 51 90 S-552 A R-21 Wall . 180 Right 552 71 90 W-400 A R-21 Wall 270 Front 400 132 90 17592 A R-38 Roof AtOt;� 1729 OPAQUE SURFACES — Cathedral Ceilings 19 01 02 03 04, w 05 06 07 08 09 10 11 Name Zone Type Orieritatio Area (ft) Skylight Area (f:2) Roof Rise (x In 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Eminence Framing Factor 1759 A R-38 Roof Atticl Left 1 30.1 30 0.2 0.02 0.95 1 0.86 0.88 1 0.07 ATTIC 01 02 48 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emfttance Radiant Barrier Cool Roof Attic Attic RoofA Ventilated 0.2 0.86 0.08 Yes Yes Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-OS-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx CF1R-PRF-01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation- Azimuth) Width (ft) Height (R) Multipli er Area (ft ) U-factor SHOC Exterior Shading 2090 Window N-552 (Left-0) -- -- 1 18.0 0.48 0.19 Insect Screen (default) 20902 Window N-552 (Left-0) - - 18.0 0.48 0.19 Insect Screen (default) 2020 Window N-552 (Left-0) -- - 1 4.0 0.34 0.25 Insect Screen (default) 20202 Window N552 (Left-0) - - 1 4.0 0.34 0.25 Insect Screen (default) 2670 Window N-552 (Left-0) -- - 1 17.5 0.48 0.19 Insect Screen (default) 26702 Window N-552 (Left-0) - - 1 17.5 0.48 0.19 Insect Screen (default) 26703 Window E-400 (Back-90) - 1 17.5 0.48 0.19 Insect Screen (default) 26704 Window E-400 (Back-90) -- 1 17.5 0.48 0.19 Insect Screen (default) 8020 Window E-400 (Back-90) - - 1 16.0 0.34 0.25 Insect Screen (default) 6020 Window S552 (Right-180) - - 1 12.0 0.34 0.25 Insect Screen (default) 26705 Window S-552(Right-180) - - 1 17.5 0.48 019 Insect Screen (default) 26706 Window S552 (Right-180) AV - - 1 17.5 0.48 0.19 Insect Screen (default) 3080 Window W-400 (From-270) V 3.0 8.0 1 24.0 0.53 0.18 Insect Screen (default) 12090 Window W-400 (From-270) 411012.0 9.0 1 108.0 0.38 0.23 Insect Screen (default) 4 S.F. Skylight 1759 (Left-0) 1 4.0 0.39 0.29 4 S.F 2 Skylight 1759 (Left-0) 1 4.0 0.39 0.29 4 S.F. 3 Skylight 1759 (Left-0) 1 4.0 0.39 0.29 7.50 S.F Skylight 1759 (Le" 1 ' 5 0.39 0.29 3.5 S.F Skylight 1759 ( ) 1 3.5 0.39 0.29 3.5 S.F. 2 Skylight 1759>;left-0) 3.5 0.39 0.29 3.5 S.F 3 Skylight 1709 (Left-0) 3.5 10.39 0.29 DOORS 01 02 03 04 Name 04; Side of Building Area (1tz) U-factor 3002 4® S-552 24.0 0.50 Registration Number: Registration Date%Tme: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx CFI R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 103 04 OS O6 07 1OB 109 10 11 1 12 1 13 1 14 Overhang Left Fin Right Fin Window Depth DistUp Left Extent Right Extent Flap Ht. Depth Top Up DIstL Bot Up Depth f Top Up Dist R Bot Up 3080 12 0.1 3 10 0 0 0 0 0 0 0 0 0 12090 12 0.1 3 10 0 0 0 0 0 0 1 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 OB 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Cavity/Frame: no insul. /2x4 Top ChM 2x4 Top Chord of Roofkiss C 24 Roof Deck: Ktod Siding/sheathing/decking Attic RoofA Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 (a24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-38/2x4 Roof Deck: Wood Sidin¢sheathing/decking R-38 Roof Atticl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board �0 • Cavity/Frame: R-21 /2x6 Exterior Finish: Wbod R-21 Wall Exterior Walls Wood Framed Walk, 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated 17593 A 1759 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required -- w, Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date%Tme: Report Version - CF1R-01212016-433 HERS Provider: Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017 Calculation Description: Tide 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx CF1R-PRF-01 Page 6 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 as Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Standard DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 06 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Propane Small Storage 50 0,58 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 SPACE CONDITIONING SYSTEMS "4:7 01 02 j 03 04 06 as SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name A-AC-1 Other Heating and Cool System T Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFumace - Fuel -fired central f imace 80 AFUE Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-05-ag 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.hbdx CF1R-PRF-01 Page 7 of 9 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SpliWrCond 11 14 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 06 06 Name Verified Airflow Airflow Target �' Vert ied EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Dud HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dirt HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target(%) Verified Dud Location Verified Dud Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-list Required `'6.0 Not Required Not Required Not Required Not Required -- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.55 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.55 r Registration Number: •�� r CA Building Energy Efficiency Standards - Registration Date/Time: 2013 Residential Compliance Report Version - CF1R-01212016-433 HERS Provider: Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx CF1R-PRF-01 Page 8 of 9 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVenlRpt 32.59 0.25 Default 0 Required PROJECT NOTES ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. lZk Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-01212016-433 HERS Provider: Report Generated at: 2017-05-09 10:11:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Dateffime: 10:10, Tue, May 09, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Armando Chavez Company: Signature Date: TITLE 24 OF THE DESERT SERVICES INC. 5/9/2017 Address: CEAMERS Certification Identification (if applicable): 44890 Seeley Dr. cirylStatelLa Quinta, CA 92253 Phone: 7278 1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for f1l�building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of CompTance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: STEVE NIETO Company: Date Signed: SOUTH WEST CONCEPTS INC. _ Address: License: 78-115 CALLE ESTADO STE 2105 City/StaterZip: Phone: LA QUINTA, CA 92253 760 564-4707 t5� 4�' 0 Registration Number: � CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-01212016-433 HERS Provider: Report Generated at: 2017-05-09 10:11:04 r � LL O Cc -1 a d R LL a U 2 2 u u a r � o u N G (or; C O 3 m u u LL � c a a r o u D ci c E c t C, M d 17 f Q � o � G u 7 u m � U = Ln T W c0 U Q Z W N ClN U) H Z C _ O c. Q y d 61 Q E C m O Z ., o G1 � O u a` 0 r � r L C C C C C C C C C C C C C C `o � U) U) N U) u) V) U) coCn U) u) V) V) V)n W N N N UOl N N N N N rOq N N N N C C C C C C C C C C C C C C O O u1 Ui O O O O t0 u7 O O O M O O O O 01 QI O C x N N r- � � � N N r- � � N N N O N N N N N N O O O O O O O O 01010 OO O O O O O O O 0 O O a0 � V O a0 a0 a0 7 V O m M a0 O O O O O Q] QI C � � q0 sr M M � � � � M M � � M M M M M M M M o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o c c P 6/ N O O O O U1 u"l O O U7 O O c O O O u7 U7 U7 N `m ,o a o r t I!!.6 m x O .�Ilil�i�lil!!MN t QyyE m m m O O = O O O O O O N N O O O O O O O r N N N N N N U U U L L L C C m �] m 01 Ol O7 `O J v v `- v `- = 41 � � � � n � O O O WLO O O O O O O 'L U7 z U7 z U7 z U-) z LO z U7 z O I O I O I LO LO LOLO O O h r Lo N fh n L` n d W W W u 3 co 3 3 3 3 3 3 3 3 3 3 3 3 3 3 L L L L L L L O. a a a a a a a a a a a a a aN 2) m m OI 21 W 21 O C C_ C C CC_ C C CC_ C_ C_ C_ _C �. � C. �. >. >, y} jC_ y jC_ S u) cn w U) cn U) U) Z C7 O N O N O N V O O 0 CD O O Il N Cl) LL N LL_ M LL. 0 E O O O N O N co O r cD O n O r N N O I- O ^ O 0 LL. Li u7 (n V1 VI Z O O 0 Z O N O N co N O O O (0 0 M N u) V) O Ln Uy U1 U7 N N N N N N N ti M cn m N W Z W U C U) H LU U_ Y f0 o U O w 0 aD s O a` OtoN LL a` _ M 00 N N m 0 4 0 N 3 N Ly m U) O o U7 ch d E n m O c 0 m N 0 0 0 0 CD 0 m LO N N O O °o O io c o Z o � Z N C: E O O Z Q W O CY Q N O fr N M 0 rn 0 L6 O O N f4 U N N C N c� r C n w w r 00 o w LL O Q_' N a a) A LL a U i r v LL a' 4 c o u N < O 3 T 2 m LL v u C C M a n O � 0 ui c E C C, �a E O 2 w G u V �a L U S rn U) T W to U Z Q W N U LLI Z c O � c Q y a p E O Z V � d 3 V IL 0 a a O O O m c') y o O = O LL a D M t or NIx a H o 0 w o a o 0 C m O1 0 J Lnn o 0 C L IL LL m C J � o 0 C H t O a p� o 0 �.7 t0 o a m o 0 a C � 0 O O � W O) O W a O Nf O fn r O r O B L NO p N N O Ly O O 0 0 j Z o r co 0 N Q Z Q W O a � ac aR L°wt 3 wtrn c J \aa °N� q)r lVQ y W ° xaa L0to ° X °, CD m�N n C y ��aQ mN S a O�rO cao� y0iy ��.y yM�rO off° yN Oa LL y C k C LL y -j � Y � C lL y c tc al c LL lt, t 0 (D UIta SUO 0ot0 Suui c OI p 0 y at 7 ifi to (D O Y? O O O O O O e_ N at 7 U C co M N O j O H N N H U U U rn O O O O e E 0 U O c c c LL O -2 'C ppN`` V 04a, V O t U X x �% O_ H N N N X N C a U U U C o 0 u E E 0 E E m NLL m m LL m LL c U a a a o O Q. N O rn C N T F' 0 ° N .0 U Y Z O 3 Q :� ) x � U is W U U Z U m m W Z C) G 00 0 Q ° j > LQL G j Q' U O O If N 7 fA y Q 00 I? Cl)O � W 0 X Q� CY a I O U c O O Lo at Z to H W U U o C 0 I a LL O O d m a L U� 'S 0 t a � m 0 LU WS = a) h o > a, C Z Y J C Q N O) W M C o d = W m O Z CD> M co N 4 _ O m oQt ` N a C O A 7 c E E 0 N 41 rn ~ m LL ❑ N o Q. y O 7 v m T C 0 y Z w i+O m To N C m 3 � N 0 o Q N 0 0 O Z � 0 0 Q o V IL 0 � O alLU y M 0 M = O c O N Q N 00 N Z I� N Ix O LL o y E Z M rn W a O uj Z W C7 G aS H c O N E O Z ° m m J❑ N J m N 07 Y r CD w u_ o to CL m a LL i 1 v u a e a n 0 o N <_ O) C O 3 m u a u C _- Of M R c o � c C E C QC m C 7 ° C r 10 u V m U = fn N T ° ° e e o � J a c c Q 0 �c C H d CL p a E o a m � c v x W W Z 0 O W O y a c m c v e � y� C .5 ;2 co LU O C F O 7 p C O o - m o 0 T O` C C:,c m LU LL W m E O C C CM LO `m � w Z O 43 N O) CL m �T O C7 O Y C/) C c E U) a as N c N O d m x a a� W V1 � QW E m m W S o m 2 W Q Q 3 d E E m N Z w C w O C o 0 a � N_ LL Cl Q O w °D d U- lmE0 c° to Z U- U c Q m ] U. = M o o m � a E c E m m Z z o Z e� « O• O O Q1 U C m O C O O V O U d � E m o Z c c a C Eo Im c� N E C O) O E :3 LL C « L _ = y U 01 O O a U a ~ m I No E rnN m C T Vi is cn fA ) N 0 C U) (D O c m CL E U) E w p M O >- z 7 a Z L) 0 o T Q � c Z V) Q Z m u O N = E z O Z QPQ 0 W U S W a U) I I I JIMI c aci u c CL o CJ c > o U y u1 c t wO 2 0 U m a FT 0 0 CD C CL o 0 u a 0 ' V L m o CDV c C 0 N T O Z m c O N W) O w W v r U U) C m g W W W U) C 7 0 O 0 � � N a E 7 Z d a L � �T p U N O E d N to .Q U) CA w a c N C7 m Q E J Z U 0 cm O C U o 0 V U x U « e La F- m w m U m 0 0 U m d d W CL) �s o a c N d = CD w W � 2 > o z Cl) W N o W � 'j W N � rn Z U) 4 m cm M O ~ O co k N co Q o m N 01 u of 0 l L N Q M O y N � j o O Z O 0 00 O o o 0 Q U O co CD o N � w > U m O o z it -IF N w x m E C c .. a� Z O m Z a L J O O U Z c O rn c U E V a O ° U N > x � v N 0 rn O 0 r 0 N cc a� io a� cu au C7 0 O CL u W LO m cD n O N Ln CL LL U C 0 0 O CL N x 1 V LL a 2 a o u (V < o � f0 U V N � :3 u C a M a n O u a C C C, t o 10 E O � C 2 i+ G u 7 t u �p C U � LLI m U Q Z IT N 0 � U) W F- cr z o 0 a Q '� � N d d O M 0 Z O u 1° y 3 . u a` ci E J Q v c N m C 0 a Z W LU („) C O N 00 O W O O C LL V N C7 N U O Gl > d S ; _� c o w y U w CDm .] Q W o0 tlJ C L N J Q N N i > N JJ =w 0 y C c W 7 a ' Z <n LL u co � O g m j p n u a y m LL e m J o o too o m c � toV 0p aNi CA d a Z p Z a N u > CD u) >, 00 i a 3) Of Q 0 _ o W LL z v U)O LL Q C G O 7 U 5 in u Z W a O -AQ th o S `� a o O O o m w° p °o 'a °' N Q of a LL Q W a) C) N w p Q' '"� O Z m > Z N Q Q g o °0 w u04K m c a p O LL W W _ - c ) a E j J Z LL j C)A N Z FZ 3 o J m c O Q a W o YU)d LLL O O J m Y a M m ; y eo y v O C T H 0- p e, O m O J Ql COcu p M 7 F a > p a N o� c a in co Q 3 z d o "0 U LL g U m m O U P O N O. y N O J C N Q J o o 3 U o O zz > p N o O = C H o o w Z IL N L p C?LL m W W > y W > O E is C r N r O �_ o co V~J N N _ C Z LL Z F m o W t O ca LL Wcli LL Q p Z z z E u, _ E ui Z U Q = _ �+ CL O N F O E > H = > > aci 30 m d E c F o Z N F O c C>7 N- I it � m o N Q •=y Q O uiIx D N Z � z N ; E z O O O v, N 'N LL Q 0 p LL U a0 U c o p p O LL C W IX —< Q N ELL Q Q S 0- Q U of r � U- O w w a m m U a U X U U) W w ►A Q r � o W N 3: rn O o 2 @ W Z H w 00 (7 all N O L9 Cn O N to m E C Z O O m U. c3i > a U � N a W CO U Q Z W N ❑_ N U) w H Z C > a y 6) N Q Ec Z O V � m � a U O a, N 0 0 U y m E E � o 0 cc a)_ .a O E � V m � m Q m � m c d r O O N O m a) U y m F a a m o 0 r a) � n o U C .a C NE O U O y 2 m ._ `i a E a o .� m w. m _ c -0 (D m E E C N m w Y y Y C co U c0 0 �� �_C U 66 o M E 3 a d c N j O m N O Q C Oi a) 00 d o m�Q L) N H CD r• o m .m. m O ❑ U `, c a) c a) O a 64 aci W) co W 00 N C U _.L.• �+ a) a) r 1) a a) N aE m o ai CS O w o coO Y o o m O a o (.0 O U) N U Z a� c� U ca o N❑ Z a� 0 o m a m =� w O U), U c r C 0 a) o 0 a U a) m N m m m L C m a) N E CO y N CL E oc» Uc) w m a) N C o U �jo �c 10 y� c a) O a) m 0' m U C .2 a) m Z m N `o o N E 6 d N 3 L HZ m w m-,m a) m N m w o Q H c 2 s, m c N U N E Q a C 0 N p �0 rn >>n Eo- a) Z CO N a) 0 H j Y T� C N m m N a o W n a) o c p M 7 m ❑ G U CD 0 c m a m w U)w N Ul Q Nm wv 0 N m N E N W C) N .> cm .O a❑ c a) w `° W Z ❑ Q U Z O Q, � a s a) y c) `° Z a O - ch LO ❑ r W N y j j � a cc U cc N Z N m 2 F- w o) m c) O O NCN W C U W W O= Z .m L N CU �'.) Z .L--' ❑ 0 r N W m 7 o m m u 0 Z cn O _� m U a IV w _ Z> N _ c a) Z C W H O N m Z° p 2 3 N N c m w to w m E E Q a) J a 41 0 Q a 3 a) � (� B w Q E t$ Q r i Q a W � y U N c+i y O x (n E 0-6 (n oo Q r m J O � ❑ U~ U fj U E N U) o W ROMEco U m U C_ w W U U a) 0 d N w LU1 c ,O N cr a) Ern M W co 3 `N 0 c Q) c 9 C Ln 9 m C N a, a 0 b b v y a) o, E a k y � m a O C G O al � C � U N v � v 7a cj O v a O c v b o G a O O y m d N E O o m � o O y � O � o m o 9 :0, U Loco j co to v o m C U N m 00 a z ti V � N U � (U C 7 ba o Z ay o m a m � m 'o) A a LO m a? r 0 Ln N c LL U C 0 N > r O a a) Project Information 152836 Project Name Custom View - Project western Quote Name i Slip Date Quote Not Ordered 00 Marvin Investments Pay Terms 3%10Net30 hki ir PO Number wei2rrnwnctoavwstem Ship Via Quoted by rANDYjbfinish Line Item Quantity Net Price Extended Price II Outside View (Scaled to Fit) Line Item Description Room ID: test bath PRODUCI TYPE Series 600 Direct Set 72 x 24 Frame Width = 72 Frame Height = 24 Complete Unit Thermally Broken Standard Sill Standard Stops Shipped and crated by Wester f, COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 'I Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Tempered Unit 1 Tempered Glass. :8 OA t5mmi 50'75mmi HARDWARE OPTIONS Coastal Stainless Package NFRC U Factor = 0 34 U-Far to M - i- etnc - 193 RHGC = 0.25 CR = 43 VT = 0 56 CPD = WIG-A-16-00407 .00002 Wrapping - Perimeter Options Perimeter Frame = Naiing Fin Drip Cap = Yes Drip Cap Applicaoon Method = Applied Jamb Width = 4 5" Special Order Notes: Warnings: Grilles are not available on units with Argon Gas eight (Ibs): 71.74168 Line Item Quantity Net Price Extended Price 21 Outside View (Scaled to Fit) Line Item Description Room ID: bed 2 PRODUCT TYPE Series 670 Casement Left 30 x 84 Frame Width = 30 Frame Height = 84 Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Annealed Unit I Annealed Class. 314" OA f3mm- 50"13mm) HARDWARE OPTIONS Coastal Stainless Package Rota Operator. Folding Handle Hardware Color matches Frame SCREEN INFORMATION Screen(s) Black Fiberglass Mesh Screens Bundled Seoerately NFRC V-Factor = 0.48 U•Factor-Metric = 2 7 J SHGC = 0 19 CR = 43 VT = 0 4 CPD = WIG-A-30-00149-00002 Wrapping - Perimeter Options Perimeter- Frame = Nailing Fin Drip Cap = No Jamb Wldih = 4 5' Special Order Notes Warnings: Grilles are not available on units with Argon Gas ight (lbs): 89.93105 printed by JB Finish Inc [,rented : 1 _25 2 7 2 5 Pt,1 Page 2 of 8 Project Information 152836 Pro)eCt Name Quote Name PO Number Quoted by CustomView - Project Marvin Investments rANDYIbfinish Ship Date Quote Not Ordered Pay Terms 3% 10Net30 Ship Via krT, V western 'es It? mwin dOwSyS to ms.Com .r �l Line Item Quantity Net Price Extended Price 31 1 Outside View (Scaled to Fit) Line Item Description Room ID: bed 2 PRODUCT TYPE Series 670 Casement Right 30 x 84 Frame Width = 30 Frame Height = 84 Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SotarBan 70 Argon Gas Spacer Type = Thermo-olastic Single Seat Black Spacer Color NFRC Unit Glass Strength = Annealed Unit 1 Annealed Glass 314" OA 13mm150'73mm) HARDWARE OPTIONS Coastal Stainless Package Roto Operator, Folding Handle Hardware Color matches Frame SCREEN INFORMATION Screen(s) Black Fiberglass Mesh Screens Bundled Seperately NFRC 9—mNctor = 0 48 U-Factor-Metric = 2 73 SHGC = 0 19. CR = 43. VT = 0 4 CPD = WIG-A-30-00149-000 Wrapping - Perimeter Options 02 Perimeter Frarne = Nailing Fin Drip Cap = No Jamb Width = 4 5" Special Order Notes - Warnings: Grilles are not available on units with Argon Gas ght (lbs): 89.93105 Line Item Quantity 4 1 q Outside View (Scaled to Fit) Special Order Notes. Net Price Line Item Description Room ID: garage Extended Price PRODUCT TYPE Series 600 Direct Set 24 ; 24 Frarne Width = 24 Frame Height = 24 Complete Unit Thermally Broken Standard Sit! Standard Stoos Shipped. and crated 6V Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Annealed Unit 1 Annealed Glass 3,4" OA r3mm 50"'3mm) HARDWARE OPTIONS Coastal Stainless Package NFRC .LI-Factor= 0.34. U Factor -Metric = t 9 SHGC = 0 25 CR = 42 VT = 0.57 CPO = WIG-A-16-00405.00002 Wrapping - Perimeter Options Perimeter Frame = Nailing Fin Drip Cap = No Jamb Width = 4.5" Warnings: Grilles are not available on units with Argon Gas ht (lbs): 73.82846 printed by JB Finish Inc orinted on 1 25 2'_, " Pm 'age 3 of 3 Project Information 152836 Or Project Name CUStOmVIew - Ship Project western 1 p Date Quote Not Ordered Quote Narne Marvin Investments Pay Terms 3%10Net30 PO Number Ship Via V'0 � L4tstornwinooaysystern,com Hooted by rANDYJbfinish Line Item Quantity Net Price Extended Price Outside View (Scaled to Fit) Special Order Notes: Line Item Description Room ID, entry PRODUCT TYPE Series 900 Entry Door R.glit 36 x 96 Frame Width = 36 Frarne Height = 96 Complete Unit Swing In Direction Medium Stile Thermally Broken Standard Bottom Rail Standard Sill. Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 1-0 Argon Gas Spacer Type = Thermo -plastic Single Seal Brack Sparer Color NFRC Unit Glass Strength = Tempered Unit 1 Tempered Glass VOA OA (5rnm: 62" r5mml HARDWARE OPTIONS Coastal Stainless Package Hardware Option = Multi -Point w.. Premium Dallas Black Hardware Keyed Standard Deadbolt Location Standard Continuous Hinge NFRC tJF-actor = 0 53 U-Facto r-Metric = 3 0'1,C ;0 78,' CR = 35. VT = 0 35 CPD = WIG-A-21-00215-0000 t hl1 apoing Perimeter Options Perimeter Frame = Nailing F:n Drip Cap = No Jamb Width = 4 5' Warnings: This door provides NO protection from Nater intrusion and should only be used in well protected conditions t (Ibs): 162.2349 Line Item Quantity Net Price Extended Price 61 t Outside View (Scaled to Fit) Line Item Description Room ID: living PRODUCT TYPE _. Series 600 Multi Sliding Door 3X 144 % 108 {� Frame Width = 144 Frame Height = 108 ` I 3 Panels Compiete Unit. Medium; Stile Thermally Broker, Non Thermal Lock Stile = No Flush Sill Shipped and crated oy Western COLOR OPTIONS Bronze Anodized j I GLASS OPTIONS f Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Tnermo-plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Tempered Unit 1 1 ' 2 1 3 Tempered Glass 7'8" CA (5mm 50' 5mm> HARDWARE OPTIONS iCoastal Stainless Package Hand Type = New Flush Handle Black Hardware 3 W' Rollers SCREEN INFORMATION NO SCREEN NFRC t Factor = 0.38. U-Factor-Metric = 2 15 SH$C-. :0.23i. CR = VT = 0 51 CPD = WIG-A-13-00339-00001 Wrapping - Perimeter Options Pe: imeter Frame = Equal Leq Special Order Notes: Warnings: This sill system prc v ties NO protection from vratar intrusion and should only be used .ii wel orotectrd ccin<ht.on4 (Ibs) 682.7322 printed by JB Finish Inc printed on 1 2'5.2017; 5 PNI Page 4 of 8 Project Information 152836 Project Name CustomView - Project Ship Date Quote Not Ordered western Quote Name Marvin Investments Pay Terms 3%IONet30 1, PO Number Ship Via vo � westernwnuloa+'systems.com Quoted by rANDY)bfinish Line Item Quantity Net Price Extended Price i 1 Outside View (Scaled to Fit) Special order Notes Line Item Description Room ID: I vmg PRODUCT TYPE Series 670 Casement Left 24 x 108 Frame Width = 24. Frame Height = 108 Complete Unit Thermally Broken, Sill Type = 670 Casement Sill Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit i Insulated Low E Solar Ban 70 Argon Gas Spacer Type = Thermo -plastic Single Seai Black Spacer Color NFRC Unit Glass Strength = Annealed Unit 1 Annealed Glass 7/8" OA (Srrinl; 50'.5mnv HARDWARE OPTIONS Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame SCREEN INFORMATION Screen's). BlacK Fiberglass Mesh Screens Bundled Seperately NFRC �r048;. Factor-Meinc = 2 7�IGC = 0"1�9. CR = 43 VT = 0 39 CPD = WIG-A-30-0() 00002 r2jiplrig -Perimeter Options Perimeter Frame = Nailing Fin Drip Cap = No Jamb Width = 4 5" Warnings: Grilles are not available on units with Argon Gas (lbs): 124.7237 Line Item Quantity Net Price gi 1 Outside View (Scaled to Fit) Line Item Description Room ID: living Extended Price PRODUCT TYPE Series 670 Casement Right 24 x 108 Frame Width = 24. Frame Height = 108 Cornplete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crates by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E. SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color, NFRC Unit Glass Strength = Annealed Unit 1 Annealed Glass. 718" OA ,5mm; 50"15mm) HARDWARE OPTIONS Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame SCREEN INFORMATION —� Screen's) Black Fiberglass Mesh Screens Bundled Seperately NFRC iPrFactor = 0.48. 0-Factor-Metric = 2 73, SHGG = 0 19. CR = 43 VT = 0 39 CPD = VVIG-A-30-00151-00002 rapping - Perimeter Options Perimeter Frame = Nailing Fin Dr,p Cap = No Jamb Width = 4 5 Special Order Notes Warnings: Grilles are not available on units will, Argon Gas Ibs): 124-7237 printed by JB Finish Inc printed on 1:25 2`) 17 Z)M Page 5 of 8 Project Information 152836 Project Name Custom View - Ship Project Dwestern 1 are Quote Not Ordered Quote Name Marvin Investments o PayTerms 3 /0 10Net30 PO Number we>twnwrn•wavtv,tei7rs core Ship Via V'0�1 Quoted by rANDYjbfinish Line Item Quantity Net Price Extended Price Outside View (Scaled to Fit) Line Item Description Room ID: kitchen PRODUCT TYPE Series 600 Direct Set 24 x 24 Frame Width = 24 Frame Height = 24 Complete Unit Thermally Broken Standard Sill Standard Stoos Shipped and crated oy Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit I Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seai Black Spacer Color NFRC Unit Glass Strength = Tempered Unit I Temoered Glass 3/4" OA (3mriw 50'13mm) HARDWARE OPTIONS Coastal Stainless Package T 1 NFRC jULFactor= 0.34 U-Factor-Metric = 1 93 CR = 42 yr = G 57 CPD = WIG-A-16-00405-00002 Wrapoing - Perimeter Options, Perimeter Frame = Nailing Fin Drip Cap = No Jamb Width = 4 5" Special Order Notes Warnings: Grilles are not available on units with Argon Gas bs): 36.91423 Line Item Quantity Net Price Extended Price 10 1 Outside View (Scaled to Fit) Special Order Notes: Line Item Description Room ID: rnaster PRODUCTTYPE Series 670 Casement Left 30 x 84 Frame Width = 30 Frame Height = 84 Complete Unit Thermally Broken Sill Type = 670 Casement Sill, Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -piaster. Single Seai Black Spacer Color NFRC Unit Glass Strength = Annealed Unit 1 .Annealed Glass 314" OA t3mm150":3mm, HARDWARE OPTIONS Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame SCREEN INFORMATION Screen(si. Black Fibei glass Mesh Screens Bundled Seperately NFRC U-Factor = 0 48 U-Factor-Metric = 2 73 S! GC = 0.19. CR = 43 VT = 0 4. CPD = WIG-A-30-00149 00002 Wapping - Perimeter Options Perimeter Frame = Nailing Fin Drip Cap = No Jamb Width = 4 5' Warnings: Gfoes are not available on units with Aigcn Gas s): 179.8621 printed by JB Finish Inc. printery ur- 1 25 201 , - c-n PN,1 Page 5 of 8 Project Information 152836 Project Nan'ie Customview - Project Ship Date Quote Not Ordered western Quote Name Marvin Investments Pay Terms 3%10Net30 PO Number Ship Via weiteniwindowsystemscorn Quoted by rANDYjbflnish vzo�*11 Line Item Quantity Net Price Extended Price 11 1 z Outside View (Scaled to Fit) Special Order Notes: Line Item Description Room ID: master PRODUCT TYPE Series 670 Casement Right 30 x 84 Frame Width = 30 Frame Height = 84 Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Annealed Unit 'I Annealed Glass. 3/4' CA i3mmi 50 ,3mini HARDWARE OPTIONS Coastal Stainless Package Roto Operator Folding Handle. Hardware Color matches Frame SCREEN INFORMATION Screen(s). Black Fiberglass Mash. Screens Bundled Seperately NFRC tLFgetor =0.48 U-Factor-Metric = 2 73 SHGC = 0 19. CR = 43 VT = 0 4 CPD = WIG-A-30-00149-00002 Wrapping - Perimeter Options Perimeter Frame = Nailing Fin Drip Cap = No Jamb Width = 4 5­ Warnings: Grilles are not available on units with Argon Gas ): 179.8621 Line Item Quantity Net Price Extended Price 12 1 Outside View (Scaled to Fit) Line Item Description Room ID: rn51 math PRODUCT TYPE Series 600 Duect Set 96 x 24 Frame Width = 96 Frame Height = 24 Complete Unit Thermally Broken Standard Sih Standard Stops Shipoed and crated by Western COLOR OPTIONS Bronze Anodized GLASS OPTIONS Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer Color NFRC Unit Glass Strength = Tempered Unit 1 Tempered Glass . 8' CA t5mmr 50",5mm HARDWARE OPTIONS Coastal Stainless Package NFRC U-Factor= 0.34 U-Factor-Metric = 1 93 18 GC = 0 25 CR = 43 VT = 0 56 CPD = WIG-A-16-00407-00002 01ipping Perimeter Options Perimeter Frame = Nailing F,n Drip Cap = Yes Drip Cap Application Method = Applied Jamb Width = 4 5" Speciai Order Notes Warnings: Grilles are not available on units with Argon Gas 94.88098 printed by JB Finish Inc printed on 1 25.20 ; ; Sri Ph.l Page 7 of 8 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name WELLS MARVIN RESIDENCE addition Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2017 Project Address 52880 EISENHOWER DR LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,759 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 1,759 Perim = 0' New Roof Wood Framed Attic R 38 1,729 Cool Roof New Wall Wood Framed R 21 1,571 New Door Opaque Door - no insulation 24 New FENESTRATION Orientation Area(ft) I Total Area: 339 Glazing Percentage: 19.3 % U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: 0.43 Exterior Shades Status Skylight 4.0 0.390 0.29 none none None New Skylight 4.0 0.390 0.29 none none None New Skylight 4.0 0.390 0.29 none none None New Skylight 7.5 0.390 0.29 none none None New Skylight 3.5 0.390 0.29 none none None New Skylight 3.5 0.390 0.29 none none None New Skylight 3.5 0.390 0.29 none none None New Left (N) 71.0 0.480 0.19 none none Bug Screen New Left (N) 8.0 0.340 0.25 none none Bug Screen New Rear (E) 35.0 0.480 0.19 none none Bug Screen New Rear (E) 16.0 0.340 0.25 none none Bug Screen New Right (S) 12.0 0.340 0.25 none none Bug Screen New Right (S) 35.0 0.480 0.19 none none Bug Screen New Front (lM 24.0 0.530 0.18 12.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status A -AC- Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.58 Standard New EnergyPro 6. by Ene Soft User Number 20648 /D: 2016-SWC-009-2R Pa a 12 of 17 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name WELLS MARVIN RESIDENCE addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/9/2017 Project Address 52880 EISENHOWER DR LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,759 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity ft2 Special Features Status FENESTRATION Total Area: 339FGla,,ng Percentage: 19.3 %New/Altered Average U-Factor: 0.43 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Front (l q 108.0 0.380 0.23 12.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6. by EnergySoft User Number. 20648 ID: 2016-SWC-009-2R Page 13 of 17 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-11 I (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § ] 10.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets therequirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in 150.0 h 2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.0(j)lA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.06)] B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.06)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.06)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §150.06)2C: Pipe for cooling system lines shall be insulated as specified in §150.06)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.06)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.06)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of § 150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. §110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of 150.0 k . The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1 C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)1 D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of 150.0 k . § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. §150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer §150.0(k)2G: according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other requirements in 150.0 k 2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it §150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. §150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with § I50.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k) ] 0: Intemally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l : tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of §110.10 b through 110.10(e). §I10.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §I10.10(b) through §I10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § ] 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §I 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § ] 10.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. ƒ00 o ¢ ® CD a L u { \ \ / 2 k Cl) § ° tm C ) cc / § E 3 ± 0 ( k / a; «« ] m § ' b ( § ) R® k 2 / 9 M ; § E . k % E § o N ° ) z 0 a> % z ) 7� z \ e 7 § a. t R � k ) LL o ■ CD Q $ N § 0 k § 7 ƒ z k(§ ® \ ] § § $ w c % z 5)§ r ° { ƒ G) 2 $ 0 f 2 2\ f a z § z E a§' $ £ ■ � ) \ R 0 - ; IL ƒ k o � k a § ' ° k ® 7 ) S m \ D § a) 2 0 % \ R • 2 m, & « o ) 0 r ( « -M f 2 0) ) k g & 0 U. ) § G a s C2, a$ m 0 E co o k @ c § \ « CD / y , § a. c £ § § 7 « o6 S 6 & 7 C. m E A W & a A k S g . n w ° 2 s ° § � # G a k § z w % 0 0 2 c ° ® § co n § cn ! } ■ § = 3 , f § 1 cn a - _ ; = 0 o 0 • £ a . _ 2 - � a / S \ 8« 2 2> 2 2 S 0 } q J \ m E E 0 I § CD k f I It ) § ƒ } \ \ \ I r 00 O 4- 0 N a d m L a U T 2 'C v LL ck 2 (n co W U Z Q'ItW N 0 a) Lu F- Z = 0 lY Q U) ui p M_ Z O � m d � • V IL 0 N a) C 0 v Q T C m N 7 n E 0 r 0y C E O a� n T rn N aci v_i Tf N > 00 O c E m y a� 5 rn Ec o U ro (U N E O 0 c c ca E o U O a) m N a) n m rn � a� c a) U � T7 a) w _ a) a (Uo E � m rn m c � ro CD E o w C O -p N C U V= N N E O z .m. N a) c .L.. m N N N N c C N N N 0a = O 0 m a W E r= != c c > � (' o n � m o c E Q= v 0 Q Z E c �° z E d w W V) me m E 0c-m LL;; T J Q 0 N 0 pn E -� too C r. a) m y) �" U) !r V> tS y to 0 c 0 i i« LU 7 9 y 3 .d. 0 a.M> or m o m Wa mm w ya) Etu 3 m d O y .-� -6 ml2 �,T�m > t N Q _ 0 m L O L H '�. C c mmi m x0 i W O V T E W IX O �03d a) ` O a ytAOm )ndum C 10 E O) W O N '+ c O .� C c% LL fA w0 _E N i7 C y U a) Z W 0 C'U3 W w= o ,c .3 cQ ��W LL>� i F- 2 H n 0 m al N yr C � E7 m 0IM O mCD e $ E w 3 rS —0 tmU c d C_ m ` 9 d m � C O ' c G U N R y c h C y � Cl! Ln N 7 a) to c .L+ 0 V O w� t c u m m � O V a_a i0 a C C _m a in E N c ao w 0 s d W p T m L c V � y v c W co O 4) .L to a e � ' N d 'O O E-- ca c m as v7 E2 T O O O) u c m c c w T C a) u �o tm 0 E m d =E0 °_' V N O w E C m d cm C O. c (D 7 L L O CD V w C o) G ` d « .O+ C N E a) c y O p T C m u _ CM p Z c m = N al a) 0 T r > T w O tm ar w E c w d C 9 H Z L c c W F- m m N U � O 120 N 3H 2 X U n O UJ N a o rn r o CD c U c E ';� ami 4) Z 2 2 � r 3 c O N N m 0 N o C C,m U) x I.0 O a o ami = _ E U z 3 m = o dL LO O U d am C) of O p _ Q N N E z 4 LO 4 Q N O O O Q) � 4) m m w o O N 0 a E E E 0 2 a) E m � � = m Z o d r> m U m G r o a N Q Q N cn O Q c i U m E _ Z N m L Q N O O U-) O. a) o O LL h O 00 L a) c N CD al = :_ C pp o O No U o 0 O 0 U 4 m M O co N O o LL ? w U z W N W N 0.' R z 0 U)E ZO m .. a� Q~ o u Q Z a a LL o Z o c z C9 a U. U N o Z < Z J W Z N N m x N (+1 O rn 0 Ln 0 O N fa TS m N c a) (7 t 0 n a) cr LO 0 9 r O N to N LL U c 0 0 O n m r 00 0 W W O W C2 a a) A L a U x CO w FA Q 0 W N ai O O 2 > Z (a ul U) z � W O _- 00 M O N O � O) O E � t 04 N A d 0 E c Z O y 2 U. V 7 R a U 5 N N T 01 o o 5 rn rn r H N m Q O N rl M O 0 f- 0 0 Cc_ O Q Lo LO 0 v Lo LO O v N O C9 c 0 l0 CY,7 L O) C O O C y J l9 m Q Il 'C 0 L 3 O O O O 0 °° n N C U o Q 9 9 9 9 c 0 N N N N N CO X W W W IOj U � al O O Q Q Q Q Q N W N O N O N U E � "-S to c m 'T Z Z W UJ M N W v a 0 L C O U C 'E F o w F Lu m W W o °o Of U as O y N d C O } U 0 `o c 0 °p ao U E CD L W g v � l0 0.^1 co OR n O CO y } O � Q: d r U) 00 0 w y U = o o co E LU O O t O N O O Q. �a C; U C N CD _N N M O O L O al t0 N O x LC v O a= O O Eli rn o O LO 4 � L N O N N N G O p � M w E Q cl r C C N O '� N J O m o m Q: o, m a m o U Q ; C7 Q O O HT w O C? O w 0 CD N U i 00 o O O C C O N O U O CD N C, 0 Q U Q o O U N 0 m L cn a7 co N Y Z U r _ N cn W U o U 7 O m O Z Q Z U> Z W — C U 101 1 1¢1 cm cu x v N M O rn 0 LO 0 0 N M m m aD c d r 0 0 d Ir ,FICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD vroject Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CF1R-PRF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name MARVIN RESIDENCE 02 Calculation Description Title 24 Analysis 03 Project Location 52880 EISENHOWER DR 04 City LA QLJINTA 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4b (433) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2013-4b (812) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 1759 15 Number of Zones 1 16 Slab Area (ft) 1759 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available No 20 Addition Slab Area (ft) N/A 21 Glazing Percentage (%) 18.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater underthe supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below m _ ENERGY USE SUMMARY �-- 0 w >• 05 06 07 08 En se (0 � Standard Design Proposed Design Cogrpliance Margin Percent Improvement go 1.31 0.79 0.52 39.7% ce C 1' 81.47 79.05 2.42 3.0% V I11 0.83 0.83 0.00 0.0% r H i C 32.95 34.56 -1.61 -4.9% P tovolta' toZ I-- 0.00 0.00 -- Co + ance Energy TOR 116.66 115.23 1.33 1.1% i I �! RECEIVw JAN 13 2017 Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-1�1:55 1i 1�:o QU(NTA HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 COMMUNITY DEVELOPMENT Report Generated at: 2017-01-10 10:51:50 CERTWICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Raised heel truss • Cool roof • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • —None — , ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 166.47 165.14 1.33 0.8% ` includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 --0�— - Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones N frri ` V n Qati n- I t`,o in S s rrpSystei r is MARVIN RESIDENCE 1759 1 1 1 1,E ;,CaSTRUCTION BY Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CF1 R-PRF-01 Page 3 of 9 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 A Conditioned A-AC-1 1759 9 DHW Sys 1 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt(deg) N-552 A R-21 Wall 0 Left 552 79 90 E-400 A R-21 Wall 90 Back 400 47 90 S-552 A R-21 Wall 180 Right 552 68 90 W-400 A R-21 Wall 270 Front 400 132 90 17592 A R-38 Roof Attic 1729 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio" n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor 1759 A R-38 Roof Attic1 Left 30.1 30 0.2 0.02 0.95 0.86 0.88 0.07 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic A Attic RoofA Ventilated 0.2 0.86 es Ybs U 1 1 T U i— LJA 11 `4 1 rA BUILDING & SAFETY DEPT. ROVED6 i. Y li 1 FOR CONSTRUCTION DP7, E iv Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-1013:31:55 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 HERS Provider: CaICERTS inc. Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Date[Time: 10:51, Tue, Jan 10, 2017 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CF 1 R-PRF-01 Page 4 of 9 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U-factor SHGC Exterior Shading 2090 Window N-552 (Left-0) ---- -- 1 18.0 0.35 0.30 Insect Screen (default) 20902 Window N-552 (Left-0) - - -- 1 18.0 0.35 0.30 Insect Screen (default) 2020 Window N-552 (Left-0) -- -- 1 4.0 0.35 0.30 Insect Screen (default) 20202 Window N-552 (Left-0) - - 1 4.0 0.35 0.30 Insect Screen (default) 2670 Window N-552 (Left-0) - - 1 17.5 0.35 0.30 Insect Screen (default) 26702 Window N-552 (Left-0) ---- ---- 1 17.5 0.35 0.30 Insect Screen (default) 26703 Window E-400 (Back-90) ---- --- 1 17.5 0.35 0.30 Insect Screen (default) 26704 Window E-400 (Back-90) - - 1 17.5 0.35 0.30 Insect Screen (default) 8016 Window E-400 (Back-90) ---- -- 1 12.0 0.35 0.30 Insect Screen (default) 6016 Window S-552 (Right-180) -- -- 1 9.0 0.35 0.30 Insect Screen (default) 26705 Window S-552 (Right-180) - - -- 1 17.5 0.35 0.30 Insect Screen (default) 26706 Window S-552 (Right-180) --- --- 1 17.5 0.35 0.30 Insect Screen (default) 3080 Window W400 (Front-270)" 3.0 8.0 1 24.0 0.35 0.30 Insect Screen (default) 12090 Window W-400 (Front-270) 12.0 9.0 1 108.0 0.35 0.30 Insect Screen (default) 4 S.F. Skylight 1759 (Left-0) 1 4.0 0.39 0.29 4 S.F. 2 Skylight 1759 (Left-0) 1 4.0 0.39 0.29 4 S.F. 3 Skylight 1759 (Left-0) 1 4.0 0.39 0.29 7.50 S.F.. Skylight 1759 (Left-0) 1 7.5 0.39 0.29 3.5 S.F. Skylight 1759 (Left-0) 1 3.5 0.39 0.29 3.5 S.F. 2 Skylight 1759 (Left-0) 1 3.5 110.39 0.39 0.29 3.5 S.F. 3 Skylight 1759 (Left-0) 1 3.5 0.29 r 1 A /11 11 A IT A DOORS LJ 01 02 U, U I L U I DEPV4 Name Side of Building c Fi►iea �f�_ - U-facto 1 30802 S-552 0.50 E BY Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31 :55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CF1 R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up 3080 12 0.1 3 10 0 0 0 0 0 0 0 0 0 12090 12 0.1 3 10 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofA Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. Q.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. Inside Finish: Gypsum Board -t • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Atiicl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish. Wood R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter Ift) Edge InsuI. R-value & Depth Carpeted Fraction Heated 17593 A 1759 0.1 one No �111111> M BUILDING ENVELOPE - HERS VERIFICATION BUM -DING Fx SA. ` 01 02 03 _` f Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage "i ,�i�STi UCUAW Required Not Required Not Required -- Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CF1 R-PRF-01 Page 6 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/1 DHW Standard DHW Heater 1 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Propane Small Storage 50 0.58 40000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name :Heat Pump System 1:Air Distribution System 1:HVAC Fan 1:2:3 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 1 07 " 0 10 Name Type Heating HSPF/COP Cap 47 Cap 17 Cooling SEER EERI ���i Control'- - & ?npts ERS Ve 'fication Heat Pump System 1 SplitHeatPump 8 60000 28000 14 11 i`lg �; N'TgJ Heat P mp System 1-h rs-cool BY Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF 1 R-PRF-01 Project Name: MARVIN RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Page 7 of 9 Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Required 350 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required - HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.55 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 Name Verified Fan Watt Draw BUS DING9q c tts/CFM) HVAC Fan 1-hers-fan Required APPHUV IAQ (Indoor Air Quality) FANS 01 02 03 04 , T 0$Y 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%) HERS Verification SFam IAQVentRpt 32.59 0.25 Default 0 Required Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx CFI R-PRF-01 Page 8 of 9 PROJECT NOTES ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. R"T Yh- 4, l 14 0 V I C) F F? ����TA CIS F p.p . OVED r'G '� CONSTRUCTION I p r BY Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF 1 R-PRF-01 Project Name: MARVIN RESIDENCE Calculation Description: Title 24 Analysis Calculation DatefTime: 10:51, Tue, Jan 10, 2017 Page 9 of 9 Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ Company: Signature Date: TITLE 24 OF THE DESERT 2017-01-10 11:13:13 Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Stephen Nieto`v'y� Company: Date Signed: South West Concepts 2017-01-10 13:31:55 Q�yI�TA ry Address: License: S/aFETY 78-115 Calle Estado N.A. BUILDING t City/State/Zip: Phone: La Quinta, CA 92253 760-564-4704 FOR CO��TFiUCTtO BY Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50