BRES2016-0345 Title 24I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
WELLS MARVIN RESIDENCE addition
52880 EISENHOWER DR
LA QUINTA, CA 92253
Project Designer:
SOUTH WEST CONCEPTS INC.
78-115 CALLE ESTADO STE 2105
LA QUINTA, CA 92253
760 564-4707
Report Prepared by:
Armando Chavez
TITLE 24 OF THE DESERT SERVICES INC.
44890 Seeley Dr.
La Quinta, CA 92253
760 278.1840
III MTZ
MU U a"Nsa:
Job Number:
2016-SWC-009-2R
Date:
5/9/2017
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR ONSTRUCTION
DATE
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
User Number:
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
2
3
12
14
EnergyPro 6. by EnergySoft Job Number: ID: 2016-SWC-009-2R User Number. 20648 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:10, Tue, May 09, 2017 Page 1 of 9
Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.ribdx
GENERAL INFORMATION
01
Project Name
MARVIN RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
52880 EISENHOWER DR
04
City
LA QUINTA
05
Standards Version
Compliance 2015
06
Zlp Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4b (433)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.8
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftz)
1759
15
Number of Zones
1
16
Slab Area (ftz)
1759
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
1
Natural Gas Available
No
20
Addition Slab Area (ft)
N/A
21
Glazing Percentage (%)
19.3%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CECapproved HERS provider.
03
This building Incorporates one or more Special Features shown below
This compliance analysis is raltd only for permit applications through December 31, 2016
—V
w ENERGY USE SUMMARY
04
06
as
07
08
Energy Use (kTDVfft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.37
4.66
-1.29
-38.3%
Space Cooling
82.05
73,92
8.13
9.9 %
IAQ Ventilation
0.83
0.83
0.00
0.0 %
Water Heating
32.95
34.56
1-1.61
1-4.9%
Photovoltaic Offset
--
0.00
0.00
--
Compliance Energy Total
119.20
113.97
5.23
4.4%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016A33 Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: MARVIN RESIDENCE Calculation DatelTme: 10:10, Tue, May 09, 2017 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Raised heel truss
• Cool roof
• Window overhangs and/or fins
• Exposed slab floor In conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-venfed by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (Qll)
• IAQ mechanical ventilation A.
Cooling System Verifications:
• Minimum Airflow
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications: 41
None -13
-
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)•
1169.11
163.88
6.23
3.1%
• includes calculated Appliances and Miscellaneous Energy Use (AMEUI
BUILDING - FEATURES INFORMATION
01
02
03
04
06
06
07
Project Name
Conditioned Floor Ate (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
MARVIN RESIDENCE
1759,E
1
0
1
0
1
Registration Number: ,+� Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.ribdx
CF1R-PRF-01
Page 3 of 9
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg, Ceiling
Height
Water Heating System 1
Water Heating System 2
A
Conditioned
A-AC-1
1759
9
DHW Sys
OPAQUESURFACES
01
02
03
04
05
06
07
09
Name
Zone
Construction
AxImuth
Orientation
Gross Area (ft2)
Window &Door Area (ft)
Tift (deg)
N-552
A
R-21 Wall
0
Left
552
79
90
E-400
A
R-21 Wall 0.1
90
Back
400
51
90
S-552
A
R-21 Wall .
180
Right
552
71
90
W-400
A
R-21 Wall
270
Front
400
132
90
17592
A
R-38 Roof AtOt;�
1729
OPAQUE SURFACES — Cathedral Ceilings 19
01
02
03
04, w
05
06
07
08
09
10
11
Name
Zone
Type
Orieritatio
Area (ft)
Skylight Area
(f:2)
Roof Rise
(x In 12)
Roof
Pitch
Roof Tilt
(deg)
Roof
Reflectance
Roof
Eminence
Framing
Factor
1759
A
R-38 Roof Atticl
Left
1 30.1
30
0.2
0.02
0.95
1 0.86
0.88
1 0.07
ATTIC
01
02
48
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emfttance
Radiant Barrier
Cool Roof
Attic
Attic RoofA
Ventilated
0.2
0.86
0.08
Yes
Yes
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-OS-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
CF1R-PRF-01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation- Azimuth)
Width (ft)
Height (R)
Multipli
er
Area
(ft )
U-factor
SHOC
Exterior Shading
2090
Window
N-552 (Left-0)
--
--
1
18.0
0.48
0.19
Insect Screen (default)
20902
Window
N-552 (Left-0)
-
-
18.0
0.48
0.19
Insect Screen (default)
2020
Window
N-552 (Left-0)
--
-
1
4.0
0.34
0.25
Insect Screen (default)
20202
Window
N552 (Left-0)
-
-
1
4.0
0.34
0.25
Insect Screen (default)
2670
Window
N-552 (Left-0)
--
-
1
17.5
0.48
0.19
Insect Screen (default)
26702
Window
N-552 (Left-0)
-
-
1
17.5
0.48
0.19
Insect Screen (default)
26703
Window
E-400 (Back-90)
-
1
17.5
0.48
0.19
Insect Screen (default)
26704
Window
E-400 (Back-90)
--
1
17.5
0.48
0.19
Insect Screen (default)
8020
Window
E-400 (Back-90)
-
-
1
16.0
0.34
0.25
Insect Screen (default)
6020
Window
S552 (Right-180)
-
-
1
12.0
0.34
0.25
Insect Screen (default)
26705
Window
S-552(Right-180)
-
-
1
17.5
0.48
019
Insect Screen (default)
26706
Window
S552 (Right-180) AV
-
-
1
17.5
0.48
0.19
Insect Screen (default)
3080
Window
W-400 (From-270) V
3.0
8.0
1
24.0
0.53
0.18
Insect Screen (default)
12090
Window
W-400 (From-270) 411012.0
9.0
1
108.0
0.38
0.23
Insect Screen (default)
4 S.F.
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
4 S.F 2
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
4 S.F. 3
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
7.50 S.F
Skylight
1759 (Le"
1
' 5
0.39
0.29
3.5 S.F
Skylight
1759 ( )
1
3.5
0.39
0.29
3.5 S.F. 2
Skylight
1759>;left-0)
3.5
0.39
0.29
3.5 S.F 3
Skylight
1709 (Left-0)
3.5
10.39
0.29
DOORS
01
02
03
04
Name 04;
Side of Building
Area (1tz)
U-factor
3002 4®
S-552
24.0
0.50
Registration Number: Registration Date%Tme:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433
HERS Provider:
Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
CFI R-PRF-01
Page 5 of 9
OVERHANGS AND FINS
01
02 103
04
OS
O6
07
1OB 109
10
11
1 12 1 13
1 14
Overhang
Left Fin
Right Fin
Window
Depth
DistUp
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DIstL
Bot Up
Depth
f Top Up
Dist R
Bot Up
3080
12
0.1
3
10
0
0
0
0
0
0
0
0
0
12090
12
0.1
3
10
0
0
0
0
0
0
1 0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
OB
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top ChM
2x4 Top Chord of Roofkiss C 24
Roof Deck: Ktod Siding/sheathing/decking
Attic RoofA
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 (a24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-38/2x4
Roof Deck: Wood Sidin¢sheathing/decking
R-38 Roof Atticl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.036
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
�0
• Cavity/Frame: R-21 /2x6
Exterior Finish: Wbod
R-21 Wall
Exterior Walls
Wood Framed Walk,
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
17593
A
1759
0.1
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
--
w,
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date%Tme:
Report Version - CF1R-01212016-433
HERS Provider:
Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Datemme: 10:10, Tue, May 09, 2017
Calculation Description: Tide 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
CF1R-PRF-01
Page 6 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
as
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Standard
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
06
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Propane
Small Storage
50
0,58
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03 04
05
06
07
Name
Pipe Insulation
Parallel Piping Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
SPACE CONDITIONING SYSTEMS "4:7
01
02
j 03
04
06
as
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
A-AC-1
Other Heating and Cool
System T
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFumace - Fuel -fired central f imace
80 AFUE
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01212016-433 Report Generated at: 2017-05-ag 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.hbdx
CF1R-PRF-01
Page 7 of 9
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SpliWrCond
11
14
Not Zonal
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
06
06
Name
Verified Airflow
Airflow Target
�'
Vert ied EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Dud
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dirt
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target(%)
Verified Dud
Location
Verified Dud
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-list
Required
`'6.0
Not Required
Not Required
Not Required
Not Required
--
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.55
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.55
r
Registration Number: •��
r
CA Building Energy Efficiency Standards -
Registration Date/Time:
2013 Residential Compliance Report Version - CF1R-01212016-433
HERS Provider:
Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation DateTme: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
CF1R-PRF-01
Page 8 of 9
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVenlRpt
32.59
0.25
Default
0
Required
PROJECT NOTES
ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL
CONTRACTOR RESPONSABILITY.
lZk
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01212016-433
HERS Provider:
Report Generated at: 2017-05-09 10:11:04
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Dateffime: 10:10, Tue, May 09, 2017
Calculation Description: Title 24 Analysis
Input File Name: 2R-009-52880 EINSENHOWER MARVIN RES.dbdx
CF1 R-PRF-01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Armando Chavez
Company:
Signature Date:
TITLE 24 OF THE DESERT SERVICES INC.
5/9/2017
Address:
CEAMERS Certification Identification (if applicable):
44890 Seeley Dr.
cirylStatelLa Quinta, CA 92253
Phone: 7278 1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for f1l�building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of CompTance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
STEVE NIETO
Company:
Date Signed:
SOUTH WEST CONCEPTS INC. _
Address:
License:
78-115 CALLE ESTADO STE 2105
City/StaterZip:
Phone:
LA QUINTA, CA 92253
760 564-4707
t5�
4�'
0
Registration Number: �
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF1R-01212016-433
HERS Provider:
Report Generated at: 2017-05-09 10:11:04
r �
LL O
Cc -1
a d
R
LL a
U
2
2
u
u
a
r �
o u
N G
(or; C
O 3
m u
u
LL
� c
a
a
r
o u
D
ci c
E c
t C,
M d
17 f
Q �
o �
G
u
7
u
m �
U =
Ln
T
W c0
U Q
Z
W N
ClN
U)
H
Z C
_ O
c.
Q
y
d
61 Q
E C
m O
Z .,
o
G1 �
O u
a` 0
r
�
r
L
C
C
C
C
C
C
C
C
C
C
C
C
C
C
`o
�
U)
U)
N
U)
u)
V)
U)
coCn
U)
u)
V)
V)
V)n
W
N
N
N
UOl
N
N
N
N
N
rOq
N
N
N
N
C
C
C
C
C
C
C
C
C
C
C
C
C
C
O
O
u1
Ui
O
O
O
O
t0
u7
O
O
O
M
O
O
O
O
01
QI
O
C
x
N
N
r-
�
�
�
N
N
r-
�
�
N
N
N
O
N
N
N
N
N
N
O
O
O
O
O
O
O
O
01010
OO
O
O
O
O
O
O
O
0
O
O
a0
�
V
O
a0
a0
a0
7
V
O
m
M
a0
O
O
O
O
O
Q]
QI
C
�
�
q0
sr
M
M
�
�
�
�
M
M
�
�
M
M
M
M
M
M
M
M
o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
o
c
c
P
6/ N
O
O
O
O
U1
u"l
O
O
U7
O
O
c
O
O
O
u7
U7
U7
N
`m
,o
a
o
r
t
I!!.6
m
x
O
.�Ilil�i�lil!!MN
t
QyyE
m
m
m
O
O
=
O
O
O
O
O
O
N
N
O
O
O
O
O
O
O
r
N
N
N
N
N
N
U
U
U
L
L
L
C
C
m
�]
m
01
Ol
O7
`O
J
v
v
`-
v
`-
=
41
�
�
�
�
n
�
O
O
O
WLO
O
O
O
O
O
O
'L
U7
z
U7
z
U7
z
U-)
z
LO
z
U7
z
O
I
O
I
O
I
LO
LO
LOLO
O
O
h
r
Lo
N
fh
n
L`
n
d
W
W
W
u
3
co
3
3
3
3
3
3
3
3
3
3
3
3
3
3
L
L
L
L
L
L
L
O.
a
a
a
a
a
a
a
a
a
a
a
a
a
aN
2)
m
m
OI
21
W
21
O
C
C_
C
C
CC_
C
C
CC_
C_
C_
C_
_C
�.
�
C.
�.
>.
>,
y}
jC_
y
jC_
S
u)
cn
w
U)
cn
U)
U)
Z
C7
O
N
O
N
O
N
V
O
O
0
CD
O
O
Il
N
Cl)
LL
N
LL_
M
LL.
0
E
O
O
O
N
O
N
co
O
r
cD O
n
O
r
N
N
O
I-
O
^
O
0
LL.
Li
u7
(n
V1
VI
Z
O
O
0
Z
O
N
O
N
co
N
O
O
O
(0
0
M
N
u)
V)
O
Ln
Uy
U1
U7
N
N
N
N
N
N
N
ti
M
cn
m
N
W
Z
W
U
C
U)
H
LU
U_
Y
f0
o
U
O
w
0
aD
s
O
a`
OtoN
LL
a`
_
M
00
N
N
m
0
4
0
N
3
N
Ly
m
U)
O
o
U7
ch
d
E
n
m
O
c
0
m
N
0
0
0
0
CD
0
m
LO
N
N
O
O
°o
O
io
c
o
Z
o
�
Z
N
C:
E
O
O
Z
Q
W
O
CY
Q
N
O
fr
N
M
0
rn
0
L6
O
O
N
f4
U
N
N
C
N
c�
r
C
n
w
w
r 00
o w
LL O
Q_' N
a a)
A
LL a
U
i
r
v
LL
a'
4
c
o u
N <
O 3
T 2
m LL
v
u
C
C
M a
n
O �
0
ui c
E C
C,
�a E
O 2
w G
u
V
�a L
U S
rn
U)
T
W to
U
Z Q
W
N
U
LLI
Z c
O
� c
Q
y
a p
E
O
Z
V �
d 3
V
IL 0
a
a
O
O
O
m
c')
y
o
O
=
O
LL
a
D
M
t
or
NIx
a
H
o
0
w
o
a
o
0
C
m
O1
0
J
Lnn
o
0
C
L
IL
LL
m
C
J
�
o
0
C
H
t
O
a
p�
o
0
�.7
t0
o
a
m
o
0
a
C
� 0
O
O
� W
O)
O
W
a
O
Nf
O
fn
r
O
r
O
B
L
NO
p
N
N
O
Ly
O
O
0
0
j
Z
o
r
co
0
N
Q
Z
Q
W
O
a
�
ac
aR
L°wt
3
wtrn
c
J
\aa
°N�
q)r
lVQ y W
° xaa
L0to
° X °,
CD
m�N
n C y
��aQ
mN S
a
O�rO
cao�
y0iy
��.y
yM�rO
off°
yN Oa
LL
y C
k
C LL
y -j
� Y �
C lL
y c tc
al
c LL lt, t
0
(D
UIta
SUO
0ot0
Suui
c
OI
p
0 y
at 7
ifi
to
(D
O
Y?
O
O
O
O
O
O
e_
N
at
7
U
C
co
M
N
O
j
O
H
N
N
H
U
U
U
rn
O
O
O
O
e
E
0 U
O
c
c
c
LL
O
-2 'C
ppN``
V
04a,
V
O
t
U
X
x
�%
O_
H
N
N
N
X
N
C
a
U
U
U
C
o
0
u
E
E
0
E
E
m
NLL
m
m
LL
m
LL
c
U
a
a
a
o
O
Q.
N
O
rn
C
N
T
F'
0
°
N
.0
U
Y
Z
O
3
Q
:�
)
x
�
U
is
W
U
U
Z
U
m
m
W
Z
C)
G
00
0
Q
°
j
>
LQL
G
j
Q'
U
O
O
If
N
7
fA
y
Q
00
I?
Cl)O
�
W
0
X
Q�
CY
a
I
O
U
c
O
O
Lo
at
Z
to
H
W
U
U
o
C
0
I
a
LL
O
O
d
m
a
L
U�
'S
0
t
a
�
m
0
LU
WS
=
a)
h
o
>
a,
C
Z
Y
J
C
Q
N
O)
W
M
C
o
d
=
W
m
O
Z
CD>
M
co
N
4
_
O
m
oQt
`
N
a
C
O
A
7
c
E
E
0
N
41
rn
~
m
LL
❑
N
o
Q.
y
O
7
v
m
T
C
0
y
Z
w
i+O
m
To
N
C
m
3
�
N
0
o
Q
N
0
0
O
Z
�
0
0
Q
o
V
IL
0
�
O
alLU
y
M
0
M
=
O
c
O
N
Q
N
00
N
Z
I�
N
Ix
O
LL
o
y
E
Z
M
rn
W
a
O
uj
Z
W
C7
G
aS
H
c
O
N
E
O
Z
°
m
m
J❑
N
J
m
N
07
Y
r
CD w
u_ o
to
CL m
a
LL
i
1
v
u
a
e
a
n 0
o
N <_
O) C
O 3
m u
a
u
C
_- Of
M R
c
o �
c
C
E C
QC
m
C 7
° C
r
10 u
V
m
U =
fn
N
T
°
° e
e o
�
J a c
c
Q 0
�c
C
H
d
CL
p
a
E
o
a
m
�
c
v
x
W
W
Z
0
O W
O
y
a c
m
c
v
e �
y�
C
.5
;2
co
LU
O
C
F
O
7
p
C
O
o
- m
o
0 T
O` C
C:,c
m
LU
LL W
m
E
O
C
C CM
LO
`m
� w
Z O
43
N
O)
CL
m
�T
O
C7
O
Y
C/)
C
c
E
U)
a
as
N
c
N
O
d
m
x
a
a�
W
V1
�
QW
E
m
m
W
S
o
m
2
W
Q
Q
3
d E
E
m N
Z w
C
w O C
o 0
a �
N_
LL
Cl Q
O
w °D
d
U-
lmE0 c°
to Z U-
U
c Q
m ]
U. =
M o
o
m � a
E c E
m m
Z z
o Z
e� « O•
O O
Q1 U
C m
O C
O O
V O
U
d �
E
m o
Z c
c a
C Eo
Im c� N E
C O) O E :3
LL
C « L
_ = y U
01
O
O
a U
a
~ m I
No E rnN
m C T
Vi is cn
fA )
N
0
C
U) (D
O
c m CL
E
U) E w p M O
>- z 7 a Z L)
0 o T Q � c
Z V) Q Z m
u
O N =
E z
O Z
QPQ
0 W
U S
W
a
U) I I I JIMI
c
aci
u
c
CL o
CJ
c
>
o
U y
u1
c t
wO
2
0
U
m
a
FT
0
0
CD
C
CL
o
0
u
a
0
'
V
L
m
o
CDV
c
C
0
N
T
O
Z
m
c
O
N
W)
O
w
W
v
r
U U)
C
m
g
W
W
W
U)
C
7
0
O
0
�
�
N
a
E
7
Z
d
a
L
�
�T
p
U
N
O
E
d
N
to
.Q
U)
CA
w
a
c
N
C7
m
Q
E
J
Z
U
0
cm
O
C
U
o
0
V
U
x
U
«
e
La
F-
m
w
m
U
m
0
0 U
m
d
d
W
CL)
�s
o
a
c
N
d
=
CD
w
W
�
2
>
o
z
Cl)
W
N
o
W
�
'j
W
N
�
rn
Z
U)
4
m
cm
M
O
~
O
co
k
N
co
Q
o
m
N
01
u
of
0
l
L
N
Q
M
O
y
N
�
j
o
O
Z
O
0
00
O
o
o
0
Q
U
O
co
CD
o
N
�
w
>
U
m
O
o
z
it
-IF
N
w
x
m
E
C
c
..
a�
Z
O
m
Z
a
L
J
O
O
U
Z
c
O
rn
c
U
E
V
a
O
°
U
N
>
x
�
v
N
0
rn
O
0
r
0
N
cc
a�
io
a�
cu
au
C7
0
O
CL
u
W
LO
m
cD
n
O
N
Ln
CL
LL
U
C
0
0
O
CL
N
x
1
V
LL
a
2
a
o u
(V <
o �
f0 U
V
N �
:3 u
C
a
M a
n
O u
a
C
C
C,
t o
10 E
O �
C 2
i+ G
u
7 t
u
�p C
U �
LLI m
U Q
Z IT
N
0 �
U)
W F-
cr z o
0
a
Q '�
� N
d
d O
M 0
Z O
u 1°
y 3
. u
a` ci
E
J
Q
v
c
N
m
C
0
a
Z
W
LU
(„)
C
O N
00
O
W O
O
C
LL
V
N
C7
N
U
O
Gl
>
d
S
; _�
c
o
w
y
U
w
CDm
.]
Q
W
o0
tlJ
C L
N
J Q
N
N
i
>
N
JJ
=w
0
y
C
c
W
7
a
'
Z
<n
LL
u
co
�
O
g
m
j
p
n
u
a
y
m
LL
e
m
J
o
o
too
o
m
c
�
toV
0p aNi
CA
d
a
Z
p
Z
a
N
u
>
CD
u)
>,
00
i a
3)
Of
Q
0
_
o
W
LL
z
v U)O
LL
Q
C
G
O
7
U
5
in
u
Z
W
a
O
-AQ
th
o
S
`�
a
o
O
O
o
m
w°
p
°o
'a
°'
N
Q of
a
LL
Q
W
a)
C)
N
w p
Q'
'"�
O
Z
m
>
Z
N
Q
Q
g
o
°0
w
u04K
m
c
a
p O
LL
W
W
_
- c
)
a
E
j J
Z
LL
j
C)A
N
Z
FZ
3
o
J
m
c
O
Q
a
W
o
YU)d
LLL
O
O
J
m
Y a
M
m
;
y
eo
y v
O
C
T
H
0-
p
e,
O
m
O
J Ql
COcu
p
M
7 F
a
>
p
a
N
o�
c
a
in
co
Q
3
z
d
o
"0
U
LL
g
U
m m
O
U
P
O
N
O.
y
N
O
J C
N
Q
J
o
o
3
U
o
O
zz
>
p
N
o
O
=
C
H
o
o
w
Z
IL
N
L
p
C?LL
m
W
W
>
y
W
>
O
E
is
C
r
N r
O �_
o
co
V~J
N
N
_
C
Z
LL
Z
F m
o
W
t
O
ca
LL
Wcli
LL
Q
p Z
z
z
E
u,
_
E
ui
Z
U
Q
=
_
�+
CL
O
N
F
O
E
>
H
=
>
>
aci
30
m
d
E
c
F
o
Z
N
F
O
c
C>7
N-
I
it
�
m
o
N
Q
•=y
Q
O
uiIx
D
N
Z
�
z
N
;
E
z
O O
O
v,
N
'N
LL
Q
0
p
LL
U
a0 U
c
o
p
p
O
LL
C
W
IX
—<
Q
N
ELL
Q
Q
S
0-
Q U
of
r �
U- O
w w
a m
m
U a
U
X
U
U)
W
w
►A
Q
r �
o W
N 3:
rn O
o 2
@ W
Z
H w
00
(7 all
N
O L9
Cn
O
N
to m
E
C Z
O O
m U.
c3i >
a
U �
N
a
W CO
U Q
Z
W N
❑_ N
U)
w H
Z C
> a
y
6)
N Q
Ec
Z O
V �
m �
a U
O
a,
N
0
0
U y
m E
E �
o 0
cc
a)_
.a
O E
� V
m �
m Q
m � m
c d r
O
O N O
m
a)
U
y
m F a
a
m
o 0
r
a) � n o
U C .a
C
NE O U
O
y 2 m ._
`i
a
E a
o .� m
w.
m
_
c
-0 (D
m E E
C
N
m
w Y y
Y
C
co
U
c0
0
�� �_C
U
66
o
M
E 3 a
d
c
N
j
O
m
N
O
Q
C
Oi
a)
00
d o m�Q
L) N H
CD
r•
o
m
.m.
m O
❑
U
`,
c a) c
a)
O
a
64
aci
W)
co
W
00
N
C U _.L.•
�+
a)
a) r
1)
a
a)
N
aE m o
ai
CS
O
w
o coO
Y o o
m
O
a
o (.0
O
U) N
U Z
a�
c�
U ca
o N❑
Z
a�
0 o m a
m
=� w
O
U), U
c r C
0 a) o 0
a U a) m
N m m
m
L C
m a)
N
E CO y N
CL E
oc» Uc)
w m a) N C
o
U
�jo �c
10
y� c a)
O a)
m
0'
m
U C
.2
a) m
Z
m
N
`o o N E
6 d
N 3
L
HZ
m
w
m-,m a) m N
m w o
Q
H
c
2
s, m c
N U
N
E
Q
a C 0 N
p
�0
rn
>>n Eo-
a)
Z
CO N
a)
0
H
j Y T�
C
N m
m
N
a o
W
n
a) o c
p M 7 m
❑
G
U
CD
0
c m a
m w
U)w
N
Ul
Q
Nm wv
0
N
m
N
E N
W
C)
N
.> cm .O
a❑ c
a)
w
`° W
Z
❑
Q
U
Z
O
Q, �
a s a) y c)
`°
Z
a
O
-
ch
LO
❑
r
W
N
y
j j � a cc
U
cc
N
Z
N
m 2
F-
w
o) m c)
O
O
NCN
W
C U
W
W
O= Z .m
L
N CU
�'.)
Z
.L--'
❑
0
r
N W
m
7
o m m u
0 Z
cn O
_�
m
U
a
IV
w
_
Z>
N
_
c
a)
Z
C
W
H O
N
m
Z°
p
2 3
N N
c
m w
to
w
m
E
E
Q
a)
J
a
41
0 Q
a 3
a)
� (�
B w
Q
E t$
Q r
i Q
a
W
�
y
U N c+i
y O
x (n
E 0-6
(n
oo
Q r
m
J
O
�
❑
U~
U
fj
U
E
N U)
o W
ROMEco U
m
U
C_
w
W
U
U
a)
0
d
N
w
LU1
c
,O
N
cr
a)
Ern
M
W co
3 `N
0
c Q)
c 9
C Ln
9
m
C N
a,
a
0
b
b
v
y a)
o, E
a k
y �
m
a O
C
G O
al �
C �
U N
v �
v
7a
cj
O
v
a
O
c
v
b
o G
a O O
y m d
N E O
o
m � o
O
y � O
� o
m o 9
:0, U Loco
j co
to v o
m
C U N
m 00
a z
ti
V � N
U � (U
C 7
ba o Z
ay o
m
a
m � m
'o)
A a
LO
m
a?
r
0
Ln
N
c
LL
U
C
0
N
>
r
O
a
a)
Project Information 152836
Project Name Custom View - Project western
Quote Name i Slip Date Quote Not Ordered 00
Marvin Investments Pay Terms 3%10Net30
hki ir
PO Number wei2rrnwnctoavwstem
Ship Via
Quoted by rANDYjbfinish
Line Item Quantity
Net Price Extended Price
II
Outside View (Scaled to Fit) Line Item Description
Room ID: test bath
PRODUCI TYPE
Series 600 Direct Set 72 x 24
Frame Width = 72 Frame Height = 24
Complete Unit Thermally Broken Standard Sill Standard Stops Shipped and crated by Wester f,
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 'I Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Tempered
Unit 1 Tempered Glass. :8 OA t5mmi 50'75mmi
HARDWARE OPTIONS
Coastal Stainless Package
NFRC
U Factor = 0 34 U-Far to M -
i- etnc - 193 RHGC = 0.25 CR = 43 VT = 0 56 CPD = WIG-A-16-00407 .00002
Wrapping - Perimeter Options
Perimeter Frame = Naiing Fin Drip Cap = Yes Drip Cap Applicaoon Method = Applied
Jamb Width = 4 5"
Special Order Notes:
Warnings: Grilles are not available on units with Argon Gas
eight (Ibs): 71.74168
Line Item Quantity Net Price Extended Price
21
Outside View (Scaled to Fit) Line Item Description Room ID: bed 2
PRODUCT TYPE
Series 670 Casement Left 30 x 84
Frame Width = 30 Frame Height = 84
Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit I Annealed Class. 314" OA f3mm- 50"13mm)
HARDWARE OPTIONS
Coastal Stainless Package Rota Operator. Folding Handle Hardware Color matches Frame
SCREEN INFORMATION
Screen(s) Black Fiberglass Mesh Screens Bundled Seoerately
NFRC
V-Factor = 0.48 U•Factor-Metric = 2 7 J SHGC = 0 19 CR = 43 VT = 0 4 CPD = WIG-A-30-00149-00002
Wrapping - Perimeter Options
Perimeter- Frame = Nailing Fin Drip Cap = No
Jamb Wldih = 4 5'
Special Order Notes
Warnings: Grilles are not available on units with Argon Gas
ight (lbs): 89.93105
printed by JB Finish Inc
[,rented : 1 _25 2 7 2 5 Pt,1 Page 2 of 8
Project Information 152836
Pro)eCt Name
Quote Name
PO Number
Quoted by
CustomView - Project
Marvin Investments
rANDYIbfinish
Ship Date Quote Not Ordered
Pay Terms 3% 10Net30
Ship Via
krT, V western
'es It? mwin dOwSyS to ms.Com
.r
�l
Line Item Quantity
Net Price Extended Price
31 1
Outside View (Scaled to Fit) Line Item Description
Room ID: bed 2
PRODUCT TYPE
Series 670 Casement Right 30 x 84
Frame Width = 30 Frame Height = 84
Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SotarBan 70 Argon Gas Spacer Type = Thermo-olastic Single Seat Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit 1 Annealed Glass 314" OA 13mm150'73mm)
HARDWARE OPTIONS
Coastal Stainless Package Roto Operator, Folding Handle Hardware Color matches Frame
SCREEN INFORMATION
Screen(s) Black Fiberglass Mesh Screens Bundled Seperately
NFRC
9—mNctor = 0 48 U-Factor-Metric = 2 73 SHGC = 0 19. CR = 43. VT = 0 4 CPD = WIG-A-30-00149-000
Wrapping - Perimeter Options 02
Perimeter Frarne = Nailing Fin Drip Cap = No
Jamb Width = 4 5"
Special Order Notes -
Warnings: Grilles are not available on units with Argon Gas
ght (lbs): 89.93105
Line Item Quantity
4 1 q
Outside View (Scaled to Fit)
Special Order Notes.
Net Price
Line Item Description Room ID: garage
Extended Price
PRODUCT TYPE
Series 600 Direct Set 24 ; 24
Frarne Width = 24 Frame Height = 24
Complete Unit Thermally Broken Standard Sit! Standard Stoos Shipped. and crated 6V Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit 1 Annealed Glass 3,4" OA r3mm 50"'3mm)
HARDWARE OPTIONS
Coastal Stainless Package
NFRC
.LI-Factor= 0.34. U Factor -Metric = t 9 SHGC = 0 25 CR = 42 VT = 0.57 CPO = WIG-A-16-00405.00002
Wrapping - Perimeter Options
Perimeter Frame = Nailing Fin Drip Cap = No
Jamb Width = 4.5"
Warnings: Grilles are not available on units with Argon Gas
ht (lbs): 73.82846
printed by JB Finish Inc
orinted on 1 25 2'_, " Pm 'age 3 of 3
Project Information 152836 Or
Project Name CUStOmVIew - Ship Project western
1 p Date Quote Not Ordered
Quote Narne Marvin Investments Pay Terms 3%10Net30
PO Number Ship Via V'0
� L4tstornwinooaysystern,com
Hooted by rANDYJbfinish
Line Item Quantity Net Price Extended Price
Outside View (Scaled to Fit)
Special Order Notes:
Line Item Description Room ID, entry
PRODUCT TYPE
Series 900 Entry Door R.glit 36 x 96
Frame Width = 36 Frarne Height = 96
Complete Unit Swing In Direction Medium Stile Thermally Broken Standard Bottom Rail Standard Sill.
Shipped and crated by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 1-0 Argon Gas Spacer Type = Thermo -plastic Single Seal Brack Sparer
Color NFRC Unit Glass Strength = Tempered
Unit 1 Tempered Glass VOA OA (5rnm: 62" r5mml
HARDWARE OPTIONS
Coastal Stainless Package Hardware Option = Multi -Point w.. Premium Dallas Black Hardware Keyed
Standard Deadbolt Location Standard Continuous Hinge
NFRC
tJF-actor = 0 53 U-Facto r-Metric = 3 0'1,C ;0 78,' CR = 35. VT = 0 35 CPD = WIG-A-21-00215-0000 t
hl1 apoing Perimeter Options
Perimeter Frame = Nailing F:n Drip Cap = No
Jamb Width = 4 5'
Warnings: This door provides NO protection from Nater intrusion and should only be used in well protected conditions
t (Ibs): 162.2349
Line Item Quantity Net Price Extended Price
61 t
Outside View (Scaled to Fit) Line Item Description
Room ID: living
PRODUCT TYPE
_. Series 600 Multi Sliding Door 3X 144 % 108
{� Frame Width = 144 Frame Height = 108
` I 3 Panels Compiete Unit. Medium; Stile Thermally Broker, Non Thermal Lock Stile = No Flush Sill Shipped
and crated oy Western
COLOR OPTIONS
Bronze Anodized
j I GLASS OPTIONS
f Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Tnermo-plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Tempered
Unit 1 1 ' 2 1 3 Tempered Glass 7'8" CA (5mm 50' 5mm>
HARDWARE OPTIONS
iCoastal Stainless Package Hand Type = New Flush Handle Black Hardware 3 W' Rollers
SCREEN INFORMATION
NO SCREEN
NFRC
t Factor = 0.38. U-Factor-Metric = 2 15 SH$C-. :0.23i. CR = VT = 0 51 CPD = WIG-A-13-00339-00001
Wrapping - Perimeter Options
Pe: imeter Frame = Equal Leq
Special Order Notes:
Warnings: This sill system prc v ties NO protection from vratar intrusion and should only be used .ii wel orotectrd ccin<ht.on4
(Ibs) 682.7322
printed by JB Finish Inc
printed on 1 2'5.2017; 5 PNI Page 4 of 8
Project Information 152836
Project Name CustomView - Project Ship Date Quote Not Ordered western
Quote Name Marvin Investments Pay Terms 3%IONet30 1,
PO Number Ship Via vo
� westernwnuloa+'systems.com
Quoted by rANDY)bfinish
Line Item Quantity Net Price Extended Price
i 1
Outside View (Scaled to Fit)
Special order Notes
Line Item Description Room ID: I vmg
PRODUCT TYPE
Series 670 Casement Left 24 x 108
Frame Width = 24. Frame Height = 108
Complete Unit Thermally Broken, Sill Type = 670 Casement Sill Shipped and crated by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit i Insulated Low E Solar Ban 70 Argon Gas Spacer Type = Thermo -plastic Single Seai Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit 1 Annealed Glass 7/8" OA (Srrinl; 50'.5mnv
HARDWARE OPTIONS
Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame
SCREEN INFORMATION
Screen's). BlacK Fiberglass Mesh Screens Bundled Seperately
NFRC
�r048;. Factor-Meinc = 2 7�IGC = 0"1�9. CR = 43 VT = 0 39 CPD = WIG-A-30-0() 00002
r2jiplrig -Perimeter Options
Perimeter Frame = Nailing Fin Drip Cap = No
Jamb Width = 4 5"
Warnings: Grilles are not available on units with Argon Gas
(lbs): 124.7237
Line Item Quantity Net Price
gi 1
Outside View (Scaled to Fit) Line Item Description Room ID: living
Extended Price
PRODUCT TYPE
Series 670 Casement Right 24 x 108
Frame Width = 24. Frame Height = 108
Cornplete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crates by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E. SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color, NFRC Unit Glass Strength = Annealed
Unit 1 Annealed Glass. 718" OA ,5mm; 50"15mm)
HARDWARE OPTIONS
Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame
SCREEN INFORMATION
—� Screen's) Black Fiberglass Mesh Screens Bundled Seperately
NFRC
iPrFactor = 0.48. 0-Factor-Metric = 2 73, SHGG = 0 19. CR = 43 VT = 0 39 CPD = VVIG-A-30-00151-00002
rapping - Perimeter Options
Perimeter Frame = Nailing Fin Dr,p Cap = No
Jamb Width = 4 5
Special Order Notes
Warnings: Grilles are not available on units will, Argon Gas
Ibs): 124-7237
printed by JB Finish Inc
printed on 1:25 2`) 17 Z)M Page 5 of 8
Project Information 152836
Project Name Custom View - Ship
Project Dwestern
1 are Quote Not Ordered
Quote Name Marvin Investments o
PayTerms 3 /0 10Net30
PO Number we>twnwrn•wavtv,tei7rs core
Ship Via V'0�1
Quoted by rANDYjbfinish
Line Item Quantity
Net Price Extended Price
Outside View (Scaled to Fit) Line Item Description
Room ID: kitchen
PRODUCT TYPE
Series 600 Direct Set 24 x 24
Frame Width = 24 Frame Height = 24
Complete Unit Thermally Broken Standard Sill Standard Stoos Shipped and crated oy Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit I Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seai Black Spacer
Color NFRC Unit Glass Strength = Tempered
Unit I Temoered Glass 3/4" OA (3mriw 50'13mm)
HARDWARE OPTIONS
Coastal Stainless Package
T 1 NFRC
jULFactor= 0.34 U-Factor-Metric = 1 93 CR = 42 yr = G 57 CPD = WIG-A-16-00405-00002
Wrapoing - Perimeter Options,
Perimeter Frame = Nailing Fin Drip Cap = No
Jamb Width = 4 5"
Special Order Notes
Warnings: Grilles are not available on units with Argon Gas
bs): 36.91423
Line Item Quantity Net Price Extended Price
10 1
Outside View (Scaled to Fit)
Special Order Notes:
Line Item Description
Room ID: rnaster
PRODUCTTYPE
Series 670 Casement Left 30 x 84
Frame Width = 30 Frame Height = 84
Complete Unit Thermally Broken Sill Type = 670 Casement Sill, Shipped and crated by Western COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -piaster. Single Seai Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit 1 .Annealed Glass 314" OA t3mm150":3mm,
HARDWARE OPTIONS
Coastal Stainless Package Roto Operator Folding Handle Hardware Color matches Frame
SCREEN INFORMATION
Screen(si. Black Fibei glass Mesh Screens Bundled Seperately
NFRC
U-Factor = 0 48 U-Factor-Metric = 2 73 S! GC = 0.19. CR = 43 VT = 0 4. CPD = WIG-A-30-00149 00002
Wapping - Perimeter Options
Perimeter Frame = Nailing Fin Drip Cap = No
Jamb Width = 4 5'
Warnings: Gfoes are not available on units with Aigcn Gas
s): 179.8621
printed by JB Finish Inc.
printery ur- 1 25 201 , - c-n PN,1 Page 5 of 8
Project Information 152836
Project Nan'ie Customview - Project Ship Date Quote Not Ordered western
Quote Name Marvin Investments Pay Terms 3%10Net30
PO Number Ship Via weiteniwindowsystemscorn
Quoted by rANDYjbflnish vzo�*11
Line Item Quantity Net Price Extended Price
11 1 z
Outside View (Scaled to Fit)
Special Order Notes:
Line Item Description Room ID: master
PRODUCT TYPE
Series 670 Casement Right 30 x 84
Frame Width = 30 Frame Height = 84
Complete Unit Thermally Broken Sill Type = 670 Casement Sill Shipped and crated by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Annealed
Unit 'I Annealed Glass. 3/4' CA i3mmi 50 ,3mini
HARDWARE OPTIONS
Coastal Stainless Package Roto Operator Folding Handle. Hardware Color matches Frame
SCREEN INFORMATION
Screen(s). Black Fiberglass Mash. Screens Bundled Seperately
NFRC
tLFgetor =0.48 U-Factor-Metric = 2 73 SHGC = 0 19. CR = 43 VT = 0 4 CPD = WIG-A-30-00149-00002
Wrapping - Perimeter Options
Perimeter Frame = Nailing Fin Drip Cap = No
Jamb Width = 4 5
Warnings: Grilles are not available on units with Argon Gas
): 179.8621
Line Item Quantity Net Price Extended Price
12 1
Outside View (Scaled to Fit) Line Item Description Room ID: rn51 math
PRODUCT TYPE
Series 600 Duect Set 96 x 24
Frame Width = 96 Frame Height = 24
Complete Unit Thermally Broken Standard Sih Standard Stops Shipoed and crated by Western
COLOR OPTIONS
Bronze Anodized
GLASS OPTIONS
Unit 1 Insulated Low E SolarBan 70 Argon Gas Spacer Type = Thermo -plastic Single Seal Black Spacer
Color NFRC Unit Glass Strength = Tempered
Unit 1 Tempered Glass . 8' CA t5mmr 50",5mm
HARDWARE OPTIONS
Coastal Stainless Package
NFRC
U-Factor= 0.34 U-Factor-Metric = 1 93 18 GC = 0 25 CR = 43 VT = 0 56 CPD = WIG-A-16-00407-00002 01ipping Perimeter Options
Perimeter Frame = Nailing F,n Drip Cap = Yes Drip Cap Application Method = Applied
Jamb Width = 4 5"
Speciai Order Notes
Warnings: Grilles are not available on units with Argon Gas
94.88098
printed by JB Finish Inc
printed on 1 25.20 ; ; Sri Ph.l Page 7 of 8
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
WELLS MARVIN RESIDENCE addition
Building Type
10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/9/2017
Project Address
52880 EISENHOWER DR
LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,759
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
ft) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation
1,759 Perim = 0'
New
Roof Wood Framed Attic
R 38
1,729 Cool Roof
New
Wall Wood Framed
R 21
1,571
New
Door Opaque Door
-
no insulation
24
New
FENESTRATION
Orientation Area(ft)
I Total Area: 339 Glazing Percentage: 19.3 %
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor: 0.43
Exterior Shades Status
Skylight 4.0
0.390
0.29 none
none
None New
Skylight 4.0
0.390
0.29 none
none
None New
Skylight 4.0
0.390
0.29 none
none
None New
Skylight 7.5
0.390
0.29 none
none
None New
Skylight 3.5
0.390
0.29 none
none
None New
Skylight 3.5
0.390
0.29 none
none
None New
Skylight 3.5
0.390
0.29 none
none
None New
Left (N) 71.0
0.480
0.19 none
none
Bug Screen New
Left (N) 8.0
0.340
0.25 none
none
Bug Screen New
Rear (E) 35.0
0.480
0.19 none
none
Bug Screen New
Rear (E) 16.0
0.340
0.25 none
none
Bug Screen New
Right (S) 12.0
0.340
0.25 none
none
Bug Screen New
Right (S) 35.0
0.480
0.19 none
none
Bug Screen New
Front (lM 24.0
0.530
0.18 12.0
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 14.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R-Value Status
A -AC- Ducted
Ducted
Attic
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
1 Small Storage Gas
50
0.58
Standard
New
EnergyPro 6. by Ene Soft User Number 20648
/D: 2016-SWC-009-2R
Pa a 12 of 17
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
WELLS MARVIN RESIDENCE addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/9/2017
Project Address
52880 EISENHOWER DR LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,759
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ft2 Special Features Status
FENESTRATION Total Area: 339FGla,,ng Percentage: 19.3 %New/Altered Average U-Factor: 0.43
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (l q 108.0 0.380
0.23 12.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnergyPro 6. by EnergySoft User Number. 20648
ID: 2016-SWC-009-2R
Page 13 of 17
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-11 I (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(1):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § ] 10.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets therequirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in 150.0 h 2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.0(j)lA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.06)] B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.06)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.06)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.06)2C:
Pipe for cooling system lines shall be insulated as specified in §150.06)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.06)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.06)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ 150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of 150.0 k .
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1 D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of 150.0 k .
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in 150.0 k 2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § I50.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k) ] 0:
Intemally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l :
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of §110.10 b through 110.10(e).
§I10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §I10.10(b) through §I10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ ] 10.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§I 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ ] 10.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
ƒ00
o
¢ ®
CD
a
L
u
{
\
\
/
2
k
Cl)
§
°
tm
C
)
cc
/
§
E
3
±
0
(
k
/
a;
««
]
m
§
'
b
(
§
)
R®
k
2
/
9
M
;
§
E
.
k
%
E
§
o
N
°
)
z
0
a>
%
z
)
7�
z
\
e
7
§
a.
t
R
�
k
)
LL
o
■
CD
Q
$
N
§
0
k
§
7
ƒ
z
k(§
®
\
]
§
§
$
w
c
%
z
5)§
r
°
{
ƒ
G)
2
$
0
f
2
2\
f
a
z
§
z
E
a§'
$
£
■
�
)
\
R
0
-
;
IL
ƒ
k
o
�
k
a
§
'
°
k
®
7
)
S
m
\
D
§
a)
2
0
%
\
R
•
2
m,
&
«
o
)
0
r
(
«
-M
f
2
0)
)
k
g
&
0
U.
)
§
G
a
s
C2,
a$
m
0
E
co
o
k
@
c
§
\
«
CD
/
y
,
§
a.
c
£
§
§
7
«
o6
S
6
&
7
C.
m
E
A
W
&
a
A
k
S
g
.
n
w
°
2
s
°
§
�
#
G
a
k
§
z
w
%
0
0
2
c
°
®
§
co
n
§
cn
!
}
■
§
=
3
,
f
§
1
cn
a
-
_
;
=
0
o
0
•
£
a
.
_
2
-
�
a
/
S
\
8«
2
2>
2
2
S
0
}
q
J
\
m
E
E
0
I
§
CD
k
f
I
It
)
§
ƒ
}
\
\
\
I
r 00
O 4-
0
N
a d
m
L a
U
T
2
'C
v
LL
ck
2
(n
co
W
U Z Q'ItW N
0 a)
Lu
F-
Z =
0
lY Q
U)
ui p
M_
Z O
� m
d �
• V
IL 0
N
a)
C
0
v
Q
T
C
m
N
7
n
E
0
r
0y
C
E
O
a�
n
T
rn
N
aci
v_i
Tf
N
>
00
O
c
E
m
y
a�
5
rn
Ec
o
U
ro
(U
N
E
O
0
c
c
ca
E
o
U
O
a)
m
N
a)
n
m
rn
�
a�
c
a)
U
�
T7
a)
w
_
a)
a
(Uo
E
�
m
rn
m
c
�
ro
CD
E
o
w
C
O
-p
N
C
U
V=
N
N
E O
z
.m.
N
a)
c
.L.. m
N N
N
N c
C
N
N N
0a
= O
0
m
a
W
E
r= !=
c c
>
� ('
o n
� m
o c E
Q=
v 0
Q
Z E
c �° z E d
w
W
V)
me
m
E
0c-m LL;;
T
J
Q
0
N 0
pn
E
-�
too C r. a) m y) �" U)
!r V> tS y
to
0 c 0
i i«
LU
7
9
y 3 .d.
0 a.M> or m o m
Wa
mm
w
ya)
Etu 3
m
d O y
.-�
-6 ml2 �,T�m
> t N Q _
0
m
L O L
H
'�. C
c mmi m x0 i
W O V T E
W
IX
O
�03d
a) `
O a
ytAOm )ndum
C 10 E O) W O N '+ c
O
.�
C c%
LL
fA
w0
_E
N i7 C y U a) Z
W
0
C'U3 W
w=
o
,c
.3 cQ ��W LL>� i
F-
2
H n
0
m
al N
yr
C
�
E7
m 0IM
O
mCD e
$
E
w 3
rS
—0
tmU
c
d
C_ m
`
9
d
m �
C
O
' c
G
U
N
R y
c
h
C y
�
Cl!
Ln
N 7
a) to
c
.L+ 0
V
O
w�
t c
u m
m �
O
V
a_a
i0 a
C
C
_m
a in
E N
c
ao
w
0 s
d
W
p
T
m
L
c
V
�
y
v
c
W
co
O
4)
.L to
a
e �
' N
d
'O
O E--
ca
c m
as
v7
E2
T
O O
O)
u c
m
c
c
w
T C
a)
u
�o
tm 0 E
m
d
=E0
°_'
V N
O
w E
C m d
cm C
O. c (D
7 L L
O CD
V w C
o) G `
d « .O+
C N
E
a) c
y O
p
T
C m
u
_ CM
p
Z
c
m = N
al a) 0
T
r > T
w O tm
ar
w
E c
w
d C 9
H
Z
L c c
W
F- m m
N
U
�
O
120 N
3H
2
X
U
n
O UJ
N
a
o
rn
r
o
CD
c
U
c
E ';�
ami
4)
Z 2
2
�
r
3
c
O N
N
m
0
N
o
C
C,m
U)
x
I.0
O
a o
ami
=
_
E U
z
3
m
=
o
dL
LO
O
U d
am
C)
of
O
p
_
Q
N
N
E
z
4
LO
4
Q
N
O
O
O
Q)
�
4)
m
m
w
o
O
N
0
a
E
E
E
0
2
a)
E
m
�
�
=
m
Z
o
d
r>
m
U
m
G r
o
a
N
Q
Q
N
cn
O
Q c
i
U
m
E
_
Z
N
m
L
Q
N
O
O
U-)
O.
a)
o
O
LL
h
O
00
L
a)
c
N
CD
al
=
:_
C
pp
o
O
No
U
o
0
O
0
U
4
m
M
O
co
N
O
o
LL
?
w
U
z
W
N
W
N
0.'
R
z
0
U)E
ZO
m
..
a�
Q~
o
u
Q
Z
a
a
LL
o
Z
o
c
z
C9
a
U.
U
N
o
Z
<
Z
J
W
Z
N
N
m
x
N
(+1
O
rn
0
Ln
0
O
N
fa
TS
m
N
c
a)
(7
t
0
n
a)
cr
LO
0
9
r
O
N
to
N
LL
U
c
0
0
O
n
m
r 00
0 W
W O
W C2
a a)
A
L a
U
x
CO
w
FA
Q
0 W
N
ai O
O 2
> Z
(a ul
U)
z
� W
O
_- 00
M O
N
O �
O)
O
E �
t 04
N
A d
0 E
c Z
O y
2 U.
V 7
R a
U 5
N
N
T
01
o
o
5
rn
rn
r
H
N
m
Q
O
N
rl
M
O
0
f-
0
0
Cc_
O
Q
Lo
LO
0
v
Lo
LO
O
v
N
O
C9
c
0
l0
CY,7
L
O)
C
O
O
C
y
J
l9
m
Q
Il
'C
0
L
3
O
O
O
O
0
°°
n
N
C
U
o
Q
9
9
9
9
c
0
N
N
N
N
N
CO
X
W
W
W
IOj
U
�
al
O
O
Q
Q
Q
Q
Q
N
W
N
O
N
O
N
U
E
�
"-S
to
c
m
'T
Z
Z
W
UJ
M
N
W
v
a
0
L
C O
U
C
'E
F
o
w
F
Lu m
W W
o
°o
Of
U
as
O
y
N
d
C
O
}
U
0
`o c
0
°p
ao
U
E
CD
L
W
g
v
�
l0
0.^1
co
OR
n
O
CO
y
}
O
�
Q:
d
r
U)
00
0
w y
U
=
o
o
co
E
LU
O
O
t
O
N
O
O
Q.
�a
C;
U
C
N
CD
_N
N
M
O
O L
O
al
t0
N
O x
LC v
O
a=
O
O
Eli
rn
o
O
LO
4
�
L N
O
N
N
N
G
O
p
�
M
w
E
Q
cl
r
C C
N
O
'�
N
J
O
m
o
m
Q:
o,
m
a
m
o
U
Q
;
C7
Q
O
O
HT
w
O
C?
O
w
0
CD
N
U
i
00
o
O
O
C
C
O
N
O
U
O
CD
N
C,
0
Q
U
Q
o
O
U
N
0
m
L
cn
a7
co
N
Y
Z
U
r
_
N
cn
W
U
o
U
7
O
m
O
Z
Q
Z
U>
Z
W
—
C
U
101
1
1¢1
cm
cu
x
v
N
M
O
rn
0
LO
0
0
N
M
m
m
aD
c
d
r
0
0
d
Ir
,FICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
vroject Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017
Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CF1R-PRF-01
Page 1 of 9
GENERAL INFORMATION
01
Project Name
MARVIN RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
52880 EISENHOWER DR
04
City
LA QLJINTA
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4b (433)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2013-4b (812)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
1759
15
Number of Zones
1
16
Slab Area (ft)
1759
17
Number of Stories
1
18
Addition Cond. Floor Area
N/A
19
Natural Gas Available
No
20
Addition Slab Area (ft)
N/A
21
Glazing Percentage (%)
18.9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater underthe supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
m _ ENERGY USE SUMMARY
�-- 0 w
>• 05
06
07
08
En se (0 �
Standard Design
Proposed Design
Cogrpliance Margin
Percent Improvement
go
1.31
0.79
0.52
39.7%
ce C 1'
81.47
79.05
2.42
3.0%
V I11
0.83
0.83
0.00
0.0%
r H i C
32.95
34.56
-1.61
-4.9%
P tovolta' toZ I--
0.00
0.00
--
Co + ance Energy TOR
116.66
115.23
1.33
1.1%
i I
�! RECEIVw
JAN 13 2017
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-1�1:55 1i 1�:o QU(NTA HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 COMMUNITY DEVELOPMENT Report Generated at: 2017-01-10 10:51:50
CERTWICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Raised heel truss
• Cool roof
• Window overhangs and/or fins
• Exposed slab floor in conditioned zone
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
• —None — ,
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)'
166.47
165.14
1.33
0.8%
` includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
--0�— -
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
N frri ` V n Qati n-
I t`,o in S s rrpSystei
r
is
MARVIN RESIDENCE
1759
1
1
1
1,E
;,CaSTRUCTION
BY
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017
Calculation Description: Title 24 Analysis
Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CF1 R-PRF-01
Page 3 of 9
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
A
Conditioned
A-AC-1
1759
9
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt(deg)
N-552
A
R-21 Wall
0
Left
552
79
90
E-400
A
R-21 Wall
90
Back
400
47
90
S-552
A
R-21 Wall
180
Right
552
68
90
W-400
A
R-21 Wall
270
Front
400
132
90
17592
A
R-38 Roof Attic
1729
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Type
Orientatio"
n
Area (ft)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof Tilt
(deg)
Roof
Reflectance
Roof
Emittance
Framing
Factor
1759
A
R-38 Roof Attic1
Left
30.1
30
0.2
0.02
0.95
0.86
0.88
0.07
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic A
Attic RoofA
Ventilated
0.2
0.86
es
Ybs
U 1 1 T U i— LJA 11 `4 1 rA
BUILDING & SAFETY DEPT.
ROVED6 i. Y li 1
FOR CONSTRUCTION
DP7, E
iv
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-1013:31:55
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433
HERS Provider: CaICERTS inc.
Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Date[Time: 10:51, Tue, Jan 10, 2017
Calculation Description: Title 24 Analysis
Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CF 1 R-PRF-01
Page 4 of 9
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ft)
U-factor
SHGC
Exterior Shading
2090
Window
N-552 (Left-0)
----
--
1
18.0
0.35
0.30
Insect Screen (default)
20902
Window
N-552 (Left-0)
- -
--
1
18.0
0.35
0.30
Insect Screen (default)
2020
Window
N-552 (Left-0)
--
--
1
4.0
0.35
0.30
Insect Screen (default)
20202
Window
N-552 (Left-0)
-
-
1
4.0
0.35
0.30
Insect Screen (default)
2670
Window
N-552 (Left-0)
-
-
1
17.5
0.35
0.30
Insect Screen (default)
26702
Window
N-552 (Left-0)
----
----
1
17.5
0.35
0.30
Insect Screen (default)
26703
Window
E-400 (Back-90)
----
---
1
17.5
0.35
0.30
Insect Screen (default)
26704
Window
E-400 (Back-90)
-
-
1
17.5
0.35
0.30
Insect Screen (default)
8016
Window
E-400 (Back-90)
----
--
1
12.0
0.35
0.30
Insect Screen (default)
6016
Window
S-552 (Right-180)
--
--
1
9.0
0.35
0.30
Insect Screen (default)
26705
Window
S-552 (Right-180)
- -
--
1
17.5
0.35
0.30
Insect Screen (default)
26706
Window
S-552 (Right-180)
---
---
1
17.5
0.35
0.30
Insect Screen (default)
3080
Window
W400 (Front-270)"
3.0
8.0
1
24.0
0.35
0.30
Insect Screen (default)
12090
Window
W-400 (Front-270)
12.0
9.0
1
108.0
0.35
0.30
Insect Screen (default)
4 S.F.
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
4 S.F. 2
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
4 S.F. 3
Skylight
1759 (Left-0)
1
4.0
0.39
0.29
7.50 S.F..
Skylight
1759 (Left-0)
1
7.5
0.39
0.29
3.5 S.F.
Skylight
1759 (Left-0)
1
3.5
0.39
0.29
3.5 S.F. 2
Skylight
1759 (Left-0)
1
3.5
110.39
0.39
0.29
3.5 S.F. 3
Skylight
1759 (Left-0)
1
3.5
0.29
r 1 A /11 11 A IT A
DOORS
LJ
01
02
U, U I L U I
DEPV4
Name
Side of Building
c
Fi►iea �f�_
- U-facto
1
30802
S-552
0.50
E BY
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31 :55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017
Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CF1 R-PRF-01
Page 5 of 9
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Distl-
Bot Up
Depth
Top Up
Dist R
Bot Up
3080
12
0.1
3
10
0
0
0
0
0
0
0
0
0
12090
12
0.1
3
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofA
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. Q.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
Inside Finish: Gypsum Board
-t
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Atiicl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.036
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish. Wood
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter Ift)
Edge InsuI. R-value & Depth
Carpeted Fraction
Heated
17593
A
1759
0.1
one
No
�111111> M
BUILDING ENVELOPE - HERS VERIFICATION BUM -DING Fx SA. `
01
02
03 _`
f
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage "i
,�i�STi UCUAW
Required
Not Required
Not Required
--
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:51, Tue, Jan 10, 2017
Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CF1 R-PRF-01
Page 6 of 9
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/1
DHW
Standard
DHW Heater 1
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Propane
Small Storage
50
0.58
40000-Btu/hr
0
0.04
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
---
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
:Heat Pump System 1:Air Distribution System
1:HVAC Fan 1:2:3
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
HVAC - HEAT PUMPS
01
02
03
04
05
06
1 07
"
0
10
Name
Type
Heating
HSPF/COP Cap 47 Cap 17
Cooling
SEER EERI
���i
Control'- -
&
?npts
ERS
Ve 'fication
Heat Pump System 1
SplitHeatPump
8
60000
28000
14
11
i`lg �;
N'TgJ
Heat P mp System
1-h rs-cool
BY
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF 1 R-PRF-01
Project Name: MARVIN RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:51, Tue, Jan 10, 2017 Page 7 of 9
Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Not Required
Not Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
-
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.55
HVAC Fan 1-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
Name
Verified Fan Watt Draw BUS
DING9q c tts/CFM)
HVAC Fan 1-hers-fan
Required
APPHUV
IAQ (Indoor Air Quality) FANS
01
02
03
04 , T
0$Y
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
32.59
0.25
Default
0
Required
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MARVIN RESIDENCE Calculation Date/Time: 10:51, Tue, Jan 10, 2017
Calculation Description: Title 24 Analysis Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
CFI R-PRF-01
Page 8 of 9
PROJECT NOTES
ALL PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL
CONTRACTOR RESPONSABILITY.
R"T
Yh- 4, l
14 0 V I C) F F?
����TA
CIS F
p.p .
OVED
r'G '� CONSTRUCTION
I p
r BY
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF 1 R-PRF-01
Project Name: MARVIN RESIDENCE
Calculation Description: Title 24 Analysis
Calculation DatefTime: 10:51, Tue, Jan 10, 2017 Page 9 of 9
Input File Name: 009-52880 EINSENHOWER MARVIN RES.ribdx
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
ARMANDO CHAVEZ
Company:
Signature Date:
TITLE 24 OF THE DESERT
2017-01-10 11:13:13
Address:
CEA/HERS Certification Identification (If applicable):
74800 Shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Stephen Nieto`v'y�
Company:
Date Signed:
South West Concepts
2017-01-10 13:31:55 Q�yI�TA
ry
Address:
License: S/aFETY
78-115 Calle Estado
N.A. BUILDING t
City/State/Zip:
Phone:
La Quinta, CA 92253
760-564-4704 FOR CO��TFiUCTtO
BY
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-N0028035A-000000000-0000 Registration Date/Time: 2017-01-10 13:31:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03112016-433 Report Generated at: 2017-01-10 10:51:50