BRES2019-0541 Geotechnical UpdateSladden Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713
6782 Stanton Avenue, Suite C, BuenaPark, CA 90621 (714) 523-0952
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743
800 E. Florida Avenue, Hemet, CA. 92543 (951) 766-8777
www. Sladdenengineering. com
November 21, 2019
McClure Homes, LLC
52765 Claret Cove
La Quinta, California 92253
Subject: Geotechnical Update
Project No. 544-19353
19-11-527
RECEIVED
DEC 2 3 2019
Project: Proposed Custom Residence
Humboldt Boulevard - Lots 63B & 64B CITY OF LA QUINTA
The Madison Club DESIGN AND DEUELCP �tE il' DEPARTViENT
La Quinta, California
Ref: Geotechnical Investigation Report prepared by Sladden Engineering dated January
28, 2005; Project No. 544-4810, Report No. 05-01-101
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated March 2, 2006; Project No. 522-4810; Report No. 06-02-120
In accordance with your request, we have reviewed the above referenced geotechnical reports as
they relate to the design and construction of the proposed custom residence to be constructed on
Lots 63B and 64B located along Humboldt Boulevard within the Madison Club development in
the City of La Quinta, California. It is our understanding that the proposed residential structure
will be of relatively lightweight wood -frame construction and will be supported by conventional
shallow spread footings and concrete slabs on grade.
The referenced reports include recommendations pertaining to the design and construction of
residential structure foundations. The previous reports also address the potential for
liquefaction, subsidence and differential settlement. Based upon our review of the referenced
reports, it is our opinion that the structural values included in these reports remain applicable for
the design and construction of the proposed residential structure foundations.
The allowable bearing pressures recommended in the referenced Geotechnical Investigation
report remain applicable. Conventional shallow spread footings should be bottomed into
properly compacted fill material a minimum of 12 inches below lowest adjacent grade.
Continuous footings should be at least 12 inches wide and isolated pad footings should be at least
2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Sladden Engineering
i 11
November 21, 2019 -2- Project No. 544-19353
19-11-527
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.48 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is generally non -expansive and falls within the "very low" expansion category in
accordance with the 2016 (CBC) classification criteria. Slab thickness and reinforcement should
be determined by the Project Structural Engineer. We recommend a minimum floor slab
thickness of 4.0 inches and minimum reinforcement of #3 bars at 24 inches on center in both
directions. All slab reinforcement should be supported on concrete chairs to ensure that
reinforcement is placed at slab mid -height.
Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder
consisting of a polyvinyl chloride membrane such as 10-mil visqueen, or equivalent. All laps
within the membrane should be sealed and at least 2 inches of clean sand should be placed over
the membrane to promote uniform curing of the concrete. To reduce the potential for punctures,
the membrane should be placed on a pad surface that has been graded smooth without any sharp
protrusions. If a smooth surface cannot be achieved by grading, consideration should be given to
placing a 1-inch thick leveling course of sand across the pad surface prior to placement of the
membrane.
Sladden has reviewed the 2016 California Building Code (CBC) and summarized the current
seismic design parameters for the proposed structure. The seismic design category for a structure
may be determined in accordance with Section 1613 of the 2016 CBC or ASCE7. According to the
2016 CBC, Site Class D may be used to estimate design seismic loading for the proposed
structures. The 2016 CBC Seismic Design Parameters are summarized below.
Risk Category (Table 1.5-1): I1
Site Class (Table 1613.3.2): D
Ss (Figure 1613.3.1):1.530g
S1(Figure 1613.3.1): 0.722g
Fa (Table 1613.3.3(1)):1.0
Fv (Table 1613.5.3(2)):1.5
Sms (Equation 16-37 (Fa X Ss)):1.530g
Smi (Equation 16-38 (Fv X Si)): 1.082g
SDS (Equation 16-39 (2/3 X Sms)): 1.020g
SD1 (Equation 16-40 12/3 X Smi)): 0.722g
Seismic Design Category: D
The subject lot was previously graded during the rough grading of the Madison Club project site.
The rough grading included over -excavation and re -compaction of the native surface soil along
with the placement of engineered fill material to construct the building pads. The site grading is
summarized in the referenced report of Testing and Observation During Rough Grading along
with the compaction test results.
Sladden Engineering
r
November 21, 2019
-3-
Project No. 544-19353
19-11-527
Because the lots have been previously rough graded, the remedial grading required at this time
should be minimal provided that the building areas fall within the previously assumed building
envelopes. The building areas should be cleared of surface vegetation, scarified and moisture
conditioned prior to precise grading. The exposed surface should be compacted to a minimum of
90 percent relative compaction prior to fill placement. The previously removed soil and any fill
material should be placed in thin lifts at near optimum moisture content and compacted to at
least 90 percent relative compaction.
We appreciate the opportunity to provide service to you on this project. If you have any
questions regarding this letter or the referenced reports, please contact the undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderson
C3 No. C45339
Principal Engineers
CIVIL =o
ENGINEERING
SER/ra 'P,.
0
c.,
Copies: 4/McClure Homes, LLC
Sladden Engineering
Please verify that soils reports contain all of the above Information. In addition, to assure
continuity between the Investigation/reporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions,
La Qulnta Geotechnical Report Checklist
Does the "Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address" means: ;
(a) the criterion Is considered significant and mitigation measures) noted, or;
(b) the criterion is considered insighiiicant and explicitly so stated.
Y s No Criterion
❑ Foundation criteria based upon bearing capacity of natural or compacted soil.
0 Foundation criteria to mitigate the effects of expansive soils.
• ❑ Foundation criteria based upon bearing capacity, of natural or compacted soil.
0 Foundation criteria to mitigate.ihe effects of liquefaction.
Cl Foundation criteria to mitigate the effects of seismically- Induced differential
settlement,
CSC ❑ Foundation criteria to mitigate the effects of long-term differential settlement
Ci Foundation criteria to mitigate the effects of varying soil strength.
Cl Foundation criteria to mitigate e4ected total and differential settlement.
Any "No" answers to the above checklist should be noted as specific required
corrections.