04-4824 (SFD) Title 24Title 24 Report CEC Approved 2001 Building Energy Efficiency Standards Job Name Duane Jensen Residence 52-465 Via Dona La Quinta, Ca 92253 Prepared For Steven de Christopher Custom Home Design 72-067 Highway 111 Rancho Mirage, Ca 92270 ----760-346-3838 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED F0PfQQ W CT10N Energy Co EDSEnergyDn,ven Solutions Cal Title 24 Reports Energy Consultant Manual-D Duct Design Air Balancing 42-415 Warner Trail - Palm Desert, Ca 92211 760.774.3676 Fax 760.360.3670 Email: energyds(a)earthlink.net EDSEnergyDriven Solutions Note to Plan Checker, Inspectors & Builder Project Name: Duane Jensen Residence Job Number: 03022005 Project Designer: Steven de Christopher Custom Home Design This Building COMPLIES by 17.3% better than standard. Page CFA R (Addendum) • The DHW Heater needs an R-12 External Blanket • This Report includes credit for Radiant Barrier per Section 8.13 • HERS verification is required for duct testing • HERS verification is required for TXV installation 1. There is one construction assembly form on page ENV-3 for your consideration 2. Sensible cooling and heating loads are shown on pages 15-17 for the HVAC Contractor's information 3. Improper BUILDING INSULATION INSTALLATION can adversely influence the heating and cooling capacity Cal Title 24 Reports Energy Consultant Manual-D Duct Design Air Balancing 42-415 Warner Trail - Palm Desert, Ca 92211 760.774.3676 Fax 760.360.3670 Email: energydsft-earthlink.net TITLE 24 REPORT Title 24 Report for: Duane Jensen Residence 52-465 Via Dona La Quinta, Ca 92253 Project Designer: Steven de Christopher Custom Home Design 72-067 Highway 111 Rancho Mirage, Ca 92270 760-346-3838 Report Prepared By: Dave Bricker Energy Driven Solutions 42415 Warner Trail Palm Desert, CA 92211 (760) 774-3676 Job Number: 03022005 i Date: 3/3/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. i EnergyPro 3.1 By EnergySoft Job Number: D3022005 User Number: 6168 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Checklist 6 Form C-2R Computer Method Summary 8 Form ENV-3 Proposed Construction Assembly 14 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 3.1 By EnergySoft Job Number: 03022005 User Number: 6168 Certificate of Compliance: Residential (Part 1 of 2) CF-1 R Duane Jensen Residence 3/3/2005 _ Project Title Date 52-465 Via Dona La Quinta Project Address Building Permit # Energy Driven Solutions (760) 774-3676 Plan Check Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,982 ft2 Average Ceiling Height:. 11.1 ft Total Conditioned Slab Area: 4,982 ft2 Building Type: (check one or more) XI Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building Multi -Family ❑ Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: [iI Slab Floor Number of Dwelling Units: 1.00_ Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U-Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall R-21 wall (R-21.2x6.16)1/2-5/8gyp Wood 0.057 Solid Wood Door None 0.387 FENESTRATION Exterior Wall Exterior Door Shadinq Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U-Factor SHGC Shading Yes / No Yes / No Right (East) 166.5 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Front (South) 78.2 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Left (West) 190.0 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Rear (North) 400.6 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Right (Southeast) 149.3 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Front (Southwest) 59.0 0.42 0.41 Bug Screen ❑ X❑ ❑ X❑ Front (Southwest) 18.3 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ Rear (North) 68.4 0.42 0.41 Bug Screen ❑ X❑ ❑ X❑ Rear (Northeast) 10.0 0.42 0.41 Bug Screen X❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 03/03/05 09:55:33 Run Code: 1109872533 Ener Pro 3.1 By EnergySoft User Number: 6168 Job Number: 03022005 Pa e:3 of 17 Certificate of Comoliance: Residential (Part 2 of 2) CF-1 R Duane Jensen Residence 3/3/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R-Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone I HVAC Split System Ventral Furnace 80% AFUE Ducts in Attic 42 Setback Zone II HVAC Split System Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone III HVAC System Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Split Air Conditioner Split Air Conditioner Split Air Conditioner Minimum Duct Efficiency Location Duct Thermostat Location / (SEER) (attic, etc.) R-Value Type Comments 12.2 SEER Ducts in Attic 42 Setback Zone I HVAC Split System 12.1 SEER Ducts in Attic 42 Sethack 7_one II HVA(' Split System 12.1 SEER Ducts in Attic 4.2 Setback Zone III HVAC System WATER HEATING SYSTEMS Water Heater Water Heater System Name Type Rated 1 Distribution # in Input Type Syst. Btu/hr Tank Energy Fact Cap. or Recovery (gal) Efficiency ' External Standby Tank Insul. Loss (%) R-Value A O. SMITH FPS-75-230 Small Gas Recirc/Time+Temp 75-000 75 ___-0,52 n/a 12 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS I Copyright Contents 2005 Energy Driven Solutions COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Oer per Bus' ess & Professi ns Code) Documentation Author Name:JL �gj% Name: Dave Bricker Title/Firm: Steven de Christopher Custom Home Design Title/Firm: Energy Driven_ Solutions Address: 72-067 Hiahwav 111 Address: 42415 Warner Trail Rancho Mirage, Ca 92270 Telephone: 76 0-346-3 838 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (date) Palm Desert, CA 92211 Telephone: (760) 774-3 6 3 3 oS (signature) (date) (signaturelstamp) (date) Run Initiation Time: 03103105 09:56:33 Run Code: 1109872533 EnergyPro 3.1 By EnergySoft User Number: 6168 Job Number: 03022005 PageA of 17 Certificate of Compliance: Residential (Addendum) CF-1 R Duane Jensen Residence Project Title 3/3/2005 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System "A.O. SMITH FPS-75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. Plan Field The HVAC System "Zone I HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manui il. HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1248 sgft Exposed Slab Floor, 3.50" thick at Zone I - Mstr + 2 Guest Suites HIGH MASS Design(see C-2R) - Verify Thermal Mass: 701 sgft Covered Slab Floor, 3.50" thick at Zone I - Mstr + 2 Guest Suites The HVAC System "Zone II HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1581 sgft Exposed Slab Floor, 3.50" thick at Zone II - Entry/Grt Rm/DinMl The HVAC System "Zone III HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1232 sgft Exposed Slab Floor, 3.50" thick at Zone III-KitBth/Pan/LauBR HIGH MASS Design(see C-2R) - Verify Thermal Mass: 220 sgft Covered Slab Floor, 3.50" thick at Zone III-KitBth/Pan/Lau/BR HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the neia vermcation ana aiagnostic testing of tnese measures on a torm CF-6R. Plan Field The HVAC System "Zone I HVAC Split System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone I HVAC Split System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. The HVAC System "Zone II HVAC Split System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone II HVAC Split System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. The HVAC System "Zone III HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone III HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. EnergyPro 3.1 By EnergySoft User Number. 6168 Job Number: 03022005 Page.5 of 17 Mandatory Measures Checklist: Residential (Page 1 of 2) MF-1 R NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures -§150(,): Minimum R-19 ceiling insulation. El§150(b): Loose fill insulation manufacturer's labeled R-Value. ❑X "§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does not apply to exterior mass walls). `§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§1500): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. ❑X §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiftration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ® § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a§ 1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 6168 Job Number: 03022005 Page:6 of 17 Mandatory Measures Checklist: Residential (Page 2 of 2) MF-1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X `§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CIVIC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in ' conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1 /4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. X § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. �X §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures X §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 31 By EnergySoft User Number: 6168 Job Number: 03022005 Page:7 of 17� Computer Method Summary (Part 1 of 3) C-2R Duane Jensen Residence_ - 3/3/2005 Project Title Date 52-465 Via -Dona I a Quinta_ Project Address Building Permit # En giLDmen Solutions. (76� 774-3676 Docum Cation Author Telephone Plan Check/Date Computer -Performance 15 -- Field check/Date- Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.60 1.45 0.16 Space Cooling 32.17 23.79 8.38 Domestic Hot Water 5.72 7.44 -1.72 Totals 39.49 32.67 6.82 Percent better than Standard: 17.3% BUILDING COMPLIES Total Conditioned Floor Area: 4,982 ft2 Floor Construction Type: Raised Floor OX Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 22.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 55,276 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,982 ft 2 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Zone Type Zone I HVAC Spit System _ 1,aa9 _ 1"77 —0-39- -Conditioned Zoas11HVAC- Split System _ 1.581 19.762 0.32_ Conditioned Zone III HVAC System _1452 15.536 --029- C-Qnddbned OPAQUE SURFACES Solar Act. Gains Type Area U-Fac. Azm. Tilt Y / N Form 3 Reference Thermostat Vent Type Hgt. Area Setback 2 nin Setback 2 n whack Location / Comments Zone I 2oneJ Zone I Zone I y� 7nneI Zone l 7n vi 7onPl Zone Zone Zone ZnnA ZoneI Zone - Zone I Zone I Zone 11 Zone11- 7nne 11 Zone 11 Zone 11 Zone II Zone II _ ZnneIl Zone-) - - - Zone II _ Zone II _ Znne II Zone II Code: 1109872633 er: 03022005 Page:8 of 17 Computer Method Summary (Part 1 of 3) C-2R Duane Jensen Residen 3/3/2005 Project Title Date 52-465 ilia-Dona-IaQuinta Project Address Building Permit # Energ given Solutions Docume Cation Author _ (760) 774-3676 Telephone - Pian ChecklDate -Corncater Performance Compliance Method (Package or Computer) 15 Field Check/Date Climate Zone Source Energy Use Standard (kBtu/sf-yr) Design Proposed Compliance Design Margin Space Heating 1.60 1.45 0.16 Space Cooling 32.17 23.79 8.38 Domestic Hot Water 5.72 7.44 -1.72 Totals 39.49 32.67 6.82 Percent better than Standard: 17.3% BUILDING COMPLIES Total Conditioned Floor Area: 4,982 ft2 Floor Construction Type: Raised Floor OX Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 22.9% Number of Dwelling Units: 1.00 Total Conditioned Volume: 55,276 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,982 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Solar qc{, Gains Type Area U-Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C-2R Duane Jensen Residence 3/3/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type # Type Area Factor SHGC Azm. Tilt Location/ Comments _L Window Rigid _ (East)_ 24_0 n.420 0.41 90 Designer DefaultWindom Zonal 2 Window Right (East) 48.0 0.420 0.41 90 90 Designer Default Windows Zone 1 _3 Window Right (East) 24.0 0.420 0.41 90 90 Designer Default Windows Zone 1 4 Window Front (South) 13.0 0.420 0.41 180 90 Designer Default Windows Zone I 5 Window Left (West) 24.0 0.420 0.41 270 90 Designer Default Windows Zone 1 6 Window Left (West) 14.0 0.420 0.41 270 90 Designer Default Windows Zone 1 Z WMdmN Left W 24.0 0.420 0.41 270 _90 Designer Default Windows Zone I 8 Window Left (West 48.0 0.420 0.41 270 90 Designer Default Windows Zone 1 .g WjOilgYL--.eft (Vt/es4 24.0 0.420 0.41 270 gQ Desig nerrD fau_Ml- Window_ __ Zone I 10 Window Left Mew 8.0 0.420 0.41 270 _90 DesianeLlDefaultWindows Zone I 11 Window Left 48.0 0.420 0.41 270 90 Designer Default Windows Zone 1 12 Window Rear (North) 30.0 0.420 0.41 0 90 Designer Default Windows Zone I 13 Window Rear (North) 30.0 0.420 0.41 a 00 Designer Default Windows Zone 1 14 Window Right (Southeast) 4.3 0.420 0.41 135 90 Designer Default Windows Zone 11 15 Window Riaht (Southeast) 24.0 0.420 0.41 135 90 Designer Default Windows Zone 11 16 Window Front (South) 4.3 0.420 0.41 180 90 Designer Default Windows Zone II 17 Window Front South 4.3 0.420 0.41 180 90 Designer Default Windows Zone II 18 Window Front South 48.0 0.420 0.41 180 90 Designer Default Windows Zone II -12 Window Front (Southwest) 36.0 0.420 0,41 _ 225 90 Designer Default Windows Zone II 20 Window Front Southwest) 24.0 0.420 0.41 225 90 Designer Default Windows Zone II 21 Window Front Southwest) 4.3 0.420 0.41 225 90 Designer Default Windows Zone 11 22 Window Front (South) 4.3 0.420 0.41 180 90 Designer Default Windows Zone II 23 Window Front South 4.3 0.420 0.41 180 90 Designer Default Windows Zone II 24 Window Right (Southeast) 25.0 0.420 0.41 135 90 Designer Default Windows Zone II 25 Window Right (East) 48.0 0.420 0.41 90 90 Designer Default Windows Zone II 26 Window Rear North 200.0 0.420 0.41 0 90 Designer Default Windows Zone II 27 Window Rear (North) 17.1 0.420 0.41 0 90 Designer Default Windows Zone II 28 Window Rear North 17.1 0.420 0.41 0 90 Designer Default Windows Zone II 29 Window Rear North 17.1 0.420 0.41 0 90 Designer Default Windows Zone II INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC HgL Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 8.0 3.0 9.0 0.1 8.0 8.0 2 Bug Screen 0.76 8.0 6.0 9.0 0.1 8.0 8.0 3 Bug Screen 0.76 8.0 3.0 9.0 0.1 8.0 8.0 4 Bug Screen 0.76 2.5 5.5 2.0 0. 2.0 �2. 5 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 3.0 2.0 0. _2. D 7 Bug Screen 0.76 8.0 3.0 .2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 3.0 2.0 0.1. 2.0 2.0 10 Bug Screen 0.76 6.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 10.0 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 10.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 2.0 2.0 12.0 0.1 10.0 10.0 15 Bug Screen 0.76 8.0 3.0 12.0 0.1 10.0 10.0 16 Bug Screen 0.76 2.0 2.0 8.0 0.1 8.0 8.0 17 Bug Screen 0.76 2.0 2.0 8.0 0.1 8.0 8.0 18 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 2.0 2.0 6.0 0.1 6.0 6.0 22 Bug Screen 0.76 2.0 2.0 16.0 0.1 10.0 10.0 23 Bug Screen 0.76 2.0 2.0 16.0 0.1 10.0 10.0 24 Bug Screen 0.76 5.0 5.0 9.0 0.1 8.0 8.0 25 Bug Screen 0.76 8.0 6.0 9.0 0.1 8.0 8.0 26 Bug Screen 0.76 10.0 19.8 12.0 0.1 10.0 10.0 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 3.1 By EnergvSoft User Number: 6168 Job Number: 03022005 Paae:10 of 17 Computer Method Summary (Part 2 of 3) C-2R Duane Jensen Residence _ 3/3/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Act. Glazing Type Location/ Factor SHGC Azm. Tilt Comments $0 Window Rear(North) 17.1 0.420 0 41 a 9Q DeaaWne[-Default Windows Zone II 31 Window Rear (North) 27.0 0.420 0.41 0 90 Designer Default Windows Zone III 32 Window Right (East 22.5 0.420 0.41 90 90 Designer Default Windows Zone III 33 Window Rear North 21.3 0.420 0.41 0 90 Designer Default Windows Zone III 34 Window Rear (North) 48.0 0.420 0.41 0 90 Designer Default Windows Zone III 35 Window Rear (North) _ 21.3 0.420 0.41 0 90 Designer Default Windows Zone III _W Window Rear (North) 23.0 0.420 0.41 _0 _90 Designer Default Windows Zone III 37 Window Rear Northeast) 10.0 0.420 0.41 45 90 Desi ner Default Windows Zone III $$ Window. Right- (S.outheast) 24.0 D.420 0.41 135 90 Designer Default Windows 7.Qoe II _3a Window Right (Southeast) 4BA 0,420 0.41 1 Designer DefaAWindows Zone III 40 Window Right (Southeast) 24.0 0.420 0.41 135 90 Designer Default Windows Zone III 41 Window Front (Southwest) 14.0 0.420 0.41 225 90 Designer Default Windows Zone III INTERIOR AND EXTERIOR SHADING Window Right Fin Overhang Left Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 4.5 6.0 10.0 0.1 10.0 . 10.0 32 Bug Screen 0.76 4.5 5.0 20.0 0.1 10.0 10.0 33 Bug Screen 0.76 8.0 2.6 12.0 0.1 10.0 10.0 34 Bug Screen 0.76 8.0 6.0 12.0 0.1 10.0 10.0 35 Bug Screen 0.76 8.0 2.6 12.0 _0, M = 36 Bug Screen 0.76 4.8 5.0 16.0 0.1 10.0 10.0. 37 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 38 Bug Screen 0.76 8.0 3.0 8.0 6.1 8.0 8.0 39 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 40 Bug Screen 0.76 8.0 3.0 8.0 0.1 8.0 8.0 4f Bug Screen 0.76 5.0 3.0 16.0 0.1 10.0 10.0 _ Run Initiation Time:_03103/05 09:55:33_ EnergyPro 3.1 By EnergySoft User Number. 6168 Job Number. 03022005 Page:11 of 17 Computer Method Summary (Part 3 of 3) C-2R Duane Jensen Residence _ Project Title THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Type (sf) (in.) Cap. Concrete, Heavyweight 1.248 S.W --28 Concrete, Heavyweight 701 350 28 Concrete, Heavyweight_ 1.581 3.50 -28 Concrete, Heavyweight 1,232 3.50 28 Concrete. Heavyweight 220 3.50 28 PERIMETER LOSSES 3/3/2005 Date Cond. Form 3 Reference Inside R-Val. Location Comments 0.98 n/a In Zone I / Sla"n trade 0.98 n/a 2 Zone I / Slab on Grade -0A n/a 0 Zone II / Slab on Grade 0.98 n/a 0 Zone III / Slab on Grade AM n/a 2 TQarJLL/ SlatZo2Gra de F2 Insulation Type Length Factor R-Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R-Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2— Setback Zone 1 HVAC Split 8yste—m Central Furnace 80%AFUE Ducts in Attic _ 4.2 Setback Zone II HVAC Split System Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone III HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat heat pump, evap. cooling) (SEER) (attic, etc,) R-Value Type Split Air Conditioner 1Z2-SEER Duds in Attic 4.2 Setback Split Air Conditioner 12.1 SEER Ducts in Attic 4.2 _ Setback Split Air Conditioner _ 12.1 SEER Ducts in Attic 4.2 Setback WATER HEATING SYSTEMS Water Heater Water Heater System Name Type A.O. SMITH FPS-75-230 Location / Comments Zone I HVAC Split System Zone II HVAC Split System Zone III HVAC System Ratedl Tank Energy Fact! t Tank Insul. Distribution # in Input Cap. or Recovery Standby R-Value Type Syst. (Btu/hr) (gal) Efficiency Loss (%, Ext. Small Gas Reclrc/Time+Tema . _ 2 75.000 75 �0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS (Copyright Contents 2005 Energy Driven Solutions I Run Initiation Time: 03/a EnergyPro 31 By EnerroySoft User Number: 6168 Computer Method Summary (Addendum) C-2R Duane Jensen Residence 3/3/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O. SMITH FPS-75-230" Energy Factor = 0.520. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "Zone I HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manui I. HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1248 sqft Exposed Slab Floor, 3.50" thick at Zone I - Mstr + 2 Guest Suites HIGH MASS Design(see C-2R) - Verify Thermal Mass: 701 sgft Covered Slab Floor, 3.50" thick at Zone I - Mstr + 2 Guest Suites The HVAC System "Zone II HVAC Split System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1581 sgft Exposed Slab Floor, 3.50" thick at Zone II - Entry/Grt Rm/Din/HI The HVAC System "Zone III HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C-2R) - Verify Thermal Mass: 1232 sgft Exposed Slab Floor, 3.50" thick at Zone III-KitBth/Pan/LauBR HIGH MASS Design(see C-2R) - Verify Thermal Mass: 220 sgft Covered Slab Floor, 3.50" thick at Zone III-KitBth/Pan/LauBR HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provlfler. I he HLKS rater must oocument the Held veritication and diagnostic testing of these measures on a form CF-51R. Plan Field The HVAC System "Zone I HVAC Split System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone I HVAC Split System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. The HVAC System "Zone II HVAC Split System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone II HVAC Split System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. The HVAC System "Zone III HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone III HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R Form. M User Number: 6168 Job Number: 03022005 Page:13 of 17 PROPOSED CONSTRUCTION ASSEMBLY ENV - PROJECT NAME DATE Duane Jensen Residence 3/3/2005 ASSEMBLY NAME R-21 wall x6.16)1/2-5/8qyp /2-5/8 ASSEMBLY Floor TYPE X Wall (check one) L W Ceiling / Roof H U) FRAMING MATERIAL Wood p FRAMING % 15 % o Framing /o 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) DESCRIPTION OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 5/8 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 Gypsum or Plaster Board 1/2 5 6 7 8 9 INSIDE SURFACE AIR FILM THICK- NESS kMING (in.) ❑ 0.625 ❑ 0.010 © 5.500 ❑ 0.500 SUBTOTAI R-VALUE CAVITY R-VALUE (Rc) WOOD FRAME R-VALUE 0.170 0.170 0.562 0.562 0.060 0.060 21.000 5.445 0.450 0.450 0.680 0.680 22.92 7.37 RG Mr *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-lb) HC (A X B) (Btu/F-sf) 2.60 0.26 0.68 0.06 0.35 0.02 2.63 0.37 0.98 2.08 0.26 0.54 7 4 TOTAL HC 2 2 NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. 0.0436 X 0.85 ] + [ 0.1357 X 0.15 ] = 0.057 1 / Rc 1 - (Fr-/6 / 100) 11 Rf Fr% 1100 ASSEMBLY U-VALUE EnergyPro 3.1 By EnergySoft User Number. 6168 Job Number: 03022005 Page:14 of 17 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Duane Jensen Residence SYSTEM NAME Zone I HVAC Split System DATE 3/3/2005 FLOOR AREA 1,949 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 11 COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible Total Room Loads 11,237 23,355 932 360 14,077 Return Vented Lighting 0 Return Air Ducts 1,168 704 Return Fan 0 0 Ventilation 0 0 0 0 0 Supply Fan 0 0 Supply Air Ducts 1,168 704 TOTAL SYSTEM LOAD 25,690 932 E 7 7 15,485 Heating System Output per System 64,000 Total Output (Etuh) 64,E Output(Stuh/sgf) 32.8 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 24.6 Total Output (sgit/Ton) 487.2 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 1,600 64,000 64,000 Jan 12 am York H4D1H048IP3HUB16L064 U&H 32,539 9,345 Airflow (cfm) Airflow (cfm/sgft) 0.82 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK r9 9,345 Aug2 pm Airflow (cfmrron) 400.0 Outside Air (%) 0.0 Outside Air (ctm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69 6 of 69.6 of 107.2 OF Outside Air 0 cfm Supply Fan Heating Coil 1600 cfm 69.6 of Return Air Ducts Supply Air Ducts 106.8 of ROOMS' 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 111.0 / 77.6 OF 76.7 163.5 OF Outside Air Q 0 cfm Supply Fan 1600 cfm 76.7 / 63.5 °F 104 57.6 / 56.5 OF Cooling Coil Return Air Ducts Supply Air Ducts 58.3 / 56.8 of 49.9% R.H. ROOMS 76.0 / 63.3 OF ' EnergyPro 3.1 By Energy3oft User Number: 6168 Job Number. 03022005 Page:15 of 17 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Duane Jensen Residence 3/3/2005 SYSTEM NAME FLOOR AREA Zone II HVAC Split System 1,581 Number of Total Total Output (Stuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfmrron) Outside Air (%) Outside Air (cfm/sgf ) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRI 64,000 i Total Room Loads 64,000 Return Vented Lighting 40.5 Return Air Ducts Return Fan 41,000 Ventilation 41,000 Supply Fan 3.4 Supply Air Ducts COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible 1,106 19,972 1 324 14,472 0 999 724 0 0 0 0 0 0 0 0 0 999 724 � 2'9 TOTAL SYSTEM LOAD 21.9691 155 15,919 1,400 I 1,400 York H4DH042/P4HUB16L064 U&H 27,283 8,661 64,000 0.89 - 409.8 0.0 Total Adjusted System Output 27 283 8,6611 64 000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 26.0 OF 69.5 of 69.5 of = 112.5 of Outside Air 0 cfm I � 2 69.5 of 11.0/776OF Outside Air 0 cfm 767/63.8 of Supply Fan Heating Coil 1400 cfm 76.7 / 63.8 of 76.7 / 63.9 of 0 h Return Air Ducts `s 58.4 / 57.3 of Supply Fan Cooling Coil 1400 cfm �% Return Air Ducts '� Supply Air Ducts 112.0 of ROOMS 70.0 OF Supply Air Ducts 59.0 / 57.6 of 50.9% R.H. I ROOMS 76.0 / 63.6 of EnergyPr. 3.1 By Energy8oft User Number. 61168 Job Number. 03022005 Page:15 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Duane Jensen Residence SYSTEM NAME Zone III HVAC System DATE 3/3/2005 FLOOR AREA 1,452 NGINEERING CHECKS SYSTEM LOAD Number of S ems 77F771 COIL CFM I Total Room Loads 686 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK I COIL HTG. PEAK Heating System Sensible Latent I I CFM I Sensible Output per System 32,000 13,592 310 323 10,013 Total Output (Btuh) 32,000 0 Output(Btuh/sgft) 22.0 680 50 Cooling System 0 0 Output per System 30,400 0 0 0 Total Output(Btuh) 30,400 0 310 0 50 Total Output (Tons) 2.5 680 Total Output (Btuhlsgft) 20.9 11 014 14 95 Total Output (sgft ron) 573.2 Air System CFM per System Airflow (cfm) 1,000 1,000 I HVAC EQUIPMENT SELECTION York H4DH030/P4HUB12LO32 U&H 21,186 5,089 32,000 - - -- -- Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 21,186 5,089 Aug 2 pm Airflow (cfmisgft) 0.69 Airflow (chn[Ton) 394.7 32,000 Outside Air (9L) 0.0 Outside Air (cfinlsgft) 0.00 Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.5 OF 69.5 °F 99.6 OF Outside Air O 0 cfm Supply Fan Heating Coil 1000 cfm 69.5 OF Return Air Ducts Supply Air Ducts 99'1 of ROOMS 70.0 OF I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 76.6 162.9 OF 76.6 ! 63.0 OF 56.7 / 55.6 OF Outside Air 0 0 cfm Supply Fan Cooling Coil 1000 cfm 76.6 / 62.9 OF Return Air Ducts Supply Air Ducts 57.4 / 55.9 OF 47.9% R.H. ROOMS 76.0 ! 62.7 OF EnergyPro 3.1 By EnergySoft User Number. 8168 Job Number. 03022005 Page:17 of 17� 0 certificate Of compliance: residential (FORM CF-1 R) PROJECT TITLE: LOT 123 AT THE HIDEAWAY PROJECT ADDRESS_ THE HIDEAWY COUNTRY CLUB, LA QUINTA, CA DOCUMENTATION AUTHOR- SHINGLETON-ARCHITECT TELEPHONE 909,337-67" COMPLIANCE METHOD (PACKAGE OR COMPUTER) COMPUTER CLIMATE ZONE 15 GENERAL INFORMATION Total Conditioned Floor Arm: Total Conditioned Slab Floor Am: a'� sq• t£ , Average Ceimg �ht Raiding Type: 4,982 . tom. 8l ❑X Single Family 0n Multi-Famiy Front Orientation: NORTH Oum Number of Stories: two Number of Dwelling Un)ts � EAST one Flwon on Tom: �X SLAB ❑ RAISED FLOOR BOTH RADIANT BARRIER (required in Climate zones 2,4,8-15) PAGE 10F 3 DATE: 07/02/04'; BLDG. PERMr~T # PLAN CHECK / DATE FIELD CHECK / DATE EMoroement Agency Use OM, 12.0 Fir ❑ Fxistin9-Plus Addition WEST [N REQUIRED BUILDING ENVELOPE INSULATION COMPONENT FRAME TYPE TYPE - V� _ SHEATHING INSULATION TOTAL R- ASSEMBLY ST STL =STEEL INSULATION R VALUE R VALUE VALUE U-FACTOR WALL � WD (1) WALL WD 21 4.0 � � ROOF WD 32 4.0 37-� 0. ROOF/CLG WD 38 4.0 44.60 FLOOR WD 38 + 11 NONE 51.80 19 FLOOR yyD 19 SLAB EDGE NA 7 • (1) For prascxip� compli+�, TOTAL R-value and Assembl wall that meats cavity R value insulation regU1 ernenb for the Pr ctor � for a p "h,W FENESTRATION COMPONENT ORIENTATION . TYPE AREA FENESTRATION SO. FT. tJ fACT� FENESTRATION FRONT WEB SHGC FRONT 0.42 0.41 • 192 LEFT NORTH LEFT. 0.42 0.41 358 REAR EAST REAR 0.42 0.41 94 RIGHT SOUTH RIGHT 0.42 0.41 186 SKYLIGHT NORTH SKYLIGHT 0 0.42 0.41 ALL NOT REQUIRED LOCATION /COMMENTS (ATTIC, GARAGE, TYPICAL. ETC,) Z"It'5 DNA Cho'� offKf /ropv DEPT. BUG SCREEN I NOT USED Aft/ CDC certificate of compliance: residential (FORM CF-1 R) PROJECT TITLE LOT 123 AT THE HIDEAWAY PAGE 2 OF 3 HVAC SYSTEMS Note: Input hydronic or combined hyd onic data under water Heating Systems, except design heating Load Ming Equipment MINIM M DISTRIBUTION DUCT or llterrrrosfet Heat Pump (fumaoeRreat pump! etc) (AFUE or HSPF) TYPE AND LOCATION R-value PIPING Type FAN COIL /CONDENSER 9.85 (SplitConfiguiraw Package) DUCTS /ATTICIUNDER SL48 4.2 n.s.b. SPLIT ACCA MANUAL D DESIGN Cooling Equipment TYPE (air conditioner, heat Pump. evap. cooling) FAN COIL / CONDENSER MINIMUM EFFICIENCY (SEER) 17.90 DUCT LOCATION (ATTIC, ETC.) D tm ATTIC / UNDER SLAB DUCT R value 4.2 Thermostat T� n.s.b. Heat Pump uraUon (Split or Package) SPLIT aiti IAVs (wAtterftative Measures) Sealed Ducts (all climate zones) (Installer testirig and certification and HERS rater field verdcation required) TXVs or Commission approved equivalent, readily accessible (climate zones 2 and 8.15 only) Qnstalfsr tes6rg and certification and HERS rater field verification required) OR Altenrate to sealed Ducts and TXVs (see package C or D Altarrtetive Package Features for Clerrate Zone) CLIMATE ZONE Window SHGC Window U-factor SEER HEATING NOT APPLICABLE NA NA NA N.l� WATER HEATING SYSTEMS WATER HEATER DISRIBUTION TYPE NUMBER IN RATED TANK STANDBY TYPE SYSTEM INPUT KW or CAPACITY CAPACITY (GALLONS) FACTOR or RECOVERY LOSS R TANK BTU/HR EFFICIENCY INSULATION R-VALUE storage gas not �� two 0.62NA INTEGRAL rimy 40,000 .fB-'qp For smwm •• wiuw w . a,wu ocu/nr), eiectnc resistance, and heat Pump water heaters, fist Energy Factor_ For large gas storage weber heaters (rated input of greeter than 75,000 btuRrr), tilt rated input, Recovery Effiaency and Standby Loss. For instentanlous gas water heaters, list rated Input and recovery eftidertgea. SPECIAL FEATURES PACKAGE'C' AND'W: TXVs a COMMISSION APPROVED EQUIVALENT, SEALED DUCTS, RADIANT BARRIERS (see installation requirements for radient barriers in Section 8.13 of Residentiai manual). PACKAGE'C': THERMAL MASS (1Trerrnal mess type, cwmktg, thlclumm and desaoftis)_ NONE IMPUTER METHOD SUMMARY Page 1 C-21 .oject Title: .coT- !Zb -77* h'1.8-eu�y.--------------------Run: 145 07-Apr-04 ..oject Address: 12.79 California iilding Title: SINGLE FAMILY RESIDENCE )cument Author: Gerald Shingleton :lephone: Building Permit # Plan Check / Date 3mpliance Method: *RES2 1.4.0 Field Check / Date limate Zone: 15 NERGY USE SUMMARY (kBtu/ft2-yr) nergy Use Standard Design --------=----- --------------- pace Heating 4.75 pace Cooling 40.06 later Heating 5.72 'otal 50.54 ;ENERAL INFORMATION conditioned Floor Area: Average Ceiling Height: Building Type: Building Front Orientation: Glazing Area, * of Floor Area: Average Fenestration U-Value: Average Fenestration SHGC: Number of Dwelling Units: Number of Stories: Floor Construction Type: Number of Conditioned Zones: Total Conditioned Volume: BUILDING ZONE INFORMATION Floor Zone Area Volume Name (ft2) (ft3) HOUSE 4982 59784 OPAQUE SURFACES Surface Area Type (ft2) Zone = HOUSE Door 20.0 Wall 1630.0 Wall 1336.0 Wall 802.0 Wall 1354.0 Ceiling 4980.0 Floor 4982.0 Proposed Design 2.60 34.94 6.05 -------- Complies 43.60 Yes 4982 ft2 1210" ft-in SFD Single Family Detached 171 deg ' 16.6% 0.42 0.41 1.00 1 Slab on 1 59784 ft Vent Thermostat Height Type Type ( f t ) - ConditionedCEC_Standard 210" U- Insl Total Tru Slr Construction factor Rval Rval Azm Tlt Gns Type-------- Location/Comments 0.330 0 3 116 90 Yes CEC_30-Wood Outside 0.046 25 22 116 90 Yes W25.2x6.16 Outside 0.046 25 22 206 90 Yes W25.2x6.16 Outside 0.046 25 22 46 90 Yes W25.2x6.16 Outside 0.046 25 22 296 90 Yes W25.2x6.16 Outside 0.027 0 37 -- 0 Yes USERSTNDR38 Outside -- 0 -- -- 180 No S1ab140E Grade rays �)MpU`tER METHOD SUMMARY Run: 145 07-Apr-0, • roject Title_======c_________________________________________________________ ERIMETER LOSSES )erimeter Length F2 -ype (ft) Factor gone = HOUSE Exposed 5301011 0.510 Insul Insul Depth R-val --(in) Location/Comments 7 16 Outside FENESTRATION SURFACES Fenestration Exterior Shade- Over- hang Fenestration Area (ft2) - U-factor ----- SHGC Tru Azm Tilt ---------- SHGC ---- -= /Fins - -- Name_ Type ---- ----- --------- ------ --- ---- -Type---- - _ Zone = HOUSE Window 356.0 0.42 0.41 46 90 90 BugScrn BugScrn 0.76 0.76 None one NORTH EAST Window 94.0 0.42 0.42 0.41 0.41 206 46 90 BugScrn 0.76 SOUTH Window 192.0 0.42 0.41 296 90 BugScrn None WEST Window 186.0 OVERHANGS Fenestration __ --_ Length Height Left Right - - Width Height 'H' 'V' Extension Extension Name-------- ------ ------ ------ --------- --------- ------- None Left Fin Right Fin---- FINS-------------------- ------------------ Dist Dif Fenestration__ Fin Fin Ht from Fin Fin Ht frc Height Width Depth Height 'V' fens Depth He 'V'-- fey Name -------- ------ ------ ------ ------ ----- ------ ------ None THERMAL MASS Vol Cond- Area Thck Heat duct- Construction Rval Location/Comments Mass (ft2) ----- (in) ---- Cap ---- ivity ----- Type ------------ ----------- -------------- -Name----- Zone = HOUSE 880.0 1.0 19 0.09 Tile 0 Interior 0 Interior CERTILE 200.0 1.0 19 0.09 the TILE L - D - )MPUTER METHOD SUMMARY Run: 145 07-Apr-OA roject Title_______________________________________________________ ;OLAR GAIN DISTRIBUTION ?enestration ,iame ------------ None HVAC SYSTEMS Winter Sumner Fraction Fraction Targetted Thermal Mass Comments----------------------- System Name System Type--------------- Zone = HOUSE Heat P- central split Hpsplit Pump - central split HPsplit Heat pump HVAC DISTRIBUTION EFFICIENCY DETAILS System Name ------------- trane Supply Duct Surface Area ------------- 1345 WATER. HEATING SYSTEMS Refrigerant Charge and Airflow TXV N/A Yes ACCA Manual D Design -------------- Yes Minimum Equipment Efficiency 9.85 HSPF 17.90 SEER Duct Leakage Target (leakage cfm/ %- of fan cfm) Fan CFM 149.5 / 6% 2491 Distrib Water Water System Name Type --- Heater Name- Heater Type------ - Standard GAS.62EF Storage gas Gas.62EF Storage gas Gas.62EF Standard GAS.62EF SPECIAL WATER HEATING SYSTEM CREDITS Solar savings Wood stove System Name fraction boiler? ----_--- ------------ ------------- No Gas.62EF No Gas.62EF SPECIAL WATER HEATER/BOILER D13TAILS Input P-d t Water Recovery AFUE (kInpu) Heater Name Efficiency ------__-__ -------- 76% 36.00 GAS.62EF Duct Locati and R-value Attic R-4, Attic R-4 # of Energy Volume Htrs Factor (gal) - - i- 0 .62 40 1 0.62 40 Wood stove boiler pump? ------------- No No Pilot Standby Tank Light ---Loss R_value (Btuh) system/Name --- None rc.yc — OMPUTER METHOD SUM14ARY Run: 145 07-Apr-0, roject Title__________________________________________________________________ iYDRONIC DISTRIBUTION AND TERMINALS Pipe �e--------- Number run ------ - (ft) SPECIAL FEATURES, REMARKS, AND NOTES l Insul Insu Pipe diam-(in) thckR-value _(in) --r_--- 1, Heating duct register location: Ceiling. 2_ Heating duct leakage must be tested and leakage must be less than 3. Cooling duct register location: Ceiling. 4. A Thermos tatic Expansion Valve must be installed in the cooling equipment SINGLE FAMILY RESIDENCE -- Monthly Zone Report HOUSE Tair Cond. Infil Slr Wed 07-Apr-04 4:22:08 pm Ign Mass Izone -Nate -Fanv -IAQv -Cool Jan 68.72 -9366 -2255 4915 3495 -185.1 0 0 0 63.58 0 Feb 69.23 -6441 -1743 5026 2944 98.797 0 1187 0 -4.44 50.77 Mar 71.18 -4599 -1339 6904 2995 35.071 0 4081 0 -18.2 546.2 Apr 73.32 -1356 -199.3 8036 2643 -181.9 0 5831 0 -31.0 3141 May 75.46 2329.4 1011.9 8435 2467 -340.2 0 3978 0 -21.4 9946 Jun 77.43 7278.7 2540.9 9439 2274 -23.74 0 1753 0 -31.7 19787 Jul 77.85 10280 3832.9 8104 2408 1.050 0 566.9 0 -30.2 24089 Aug 77.914 9749.6 3040.6 7872 2584 13.683 0 266.2 0 -48.2 23042 Sep 77.36 5794.2 1594.7 6910 2785 51.326 0 1695 0 -59.4 15500 Oct 74.49 593.18 280.72 5644 3142 256.68 0 4458 0 -38.6 5498 Nov 68.95 -4844 -1058 4266 3297 344.81 0 2575 0 -12.5 5.475 Dec 68.21 -9177 -2556 4109 3553 10.692 0 90.35 0 29.13 0 Yr 73.34 240.15 3151.0 79661 34587 81.241 0 26482 0 -203 102k NV hrs FV hrs FV rntm F2 rntm IAQ hr CF hrs CF rntm Cl hrs Ht hrs Jan 0 0 0 0 78 0 0 0 83 Feb 93 0 0 0 81 0 0 4 27 Mar 273 0 0 0 36 0 0 34 19 Apr 395 0 0 0 41 0 0 145 0 May 308 0 0 0 30 0 0 343 0 Jun 163 0 0 0 45 0 0 539 0 Jul 77 0 0 0 33 0 0 656 0 Aug 66 0 0 0 57 0 0 674 0 Sep 188 0 0 0 79 0 0 508 0 Oct 346 .0 0 0 55 0 0 225 0 Nov 195 0 0 0 104 0 0 1 16 Dec 9 0 0 0 64 0 0 0 109 Yr 2113 0 0 0 703 0 0 3129 254 ZONE DATA for HOUSE Type: 1 SSE Ht: 0.7844 SSE Cl: 0.5836 Pk IG: 94730.0 Infil AC: 0 WA gr: 828.000 UA: 692.975 NV VHi: 41.400 Hd: 2.000 Td: 0 FV cfm: 0 Td: 0 CFA: 4982.00 Vol: 59784.0 Cair: 17437.0 FIR Ht: 0 EIR Ht: 1.275 DEff Ht: 0.815 FIR Cl: 0 EIR Cl: 1.620 DEff Cl: 0.596 ELA: 351.530 Stackc: 0.0156 WA op: 331.200 VLo: 41.400 AzI: 0 Efdi: 0.275 kW: 0 wbMax: 0 Ems: 1.000 fZone: 0 tRise: 0 CF kW: 0 fZone: 0 gZone: 0 Windc: 0.0039 Emdd: 0 DECeff : 0 havMax: 0 hydsys: -1 Emdi: 0.500 IECeff: 0 Schedule: Internal gain ( GAINSC ) Winter .0240 .0220 .0210 .0210 .0210 .0260 .0380 .0590 .0560 .0600 .0590 .04E .0450 .0300 .0280 .0310 .0570 .0640 .0640 .0520 .0500 .0550 .0440 .027 Summer .0240 .0220 .0210 .0210 .0210 .0260 .0380 .0590 .0560 .0600 .0590 .04E .0450 .0300 .0280 .0310 .0570 .0640 .0640 .0520 .0500 .0550 .0440 .027 Schedule: Heating set point ( THEAT ) Winter 60.00 60.00 60.00 60.00 60.00 60.00 60.00 68.00 68.00 68.00 68.00 68.0 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 60.0 Summer 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.0 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 60.( Schedule: Desired temp ( TDSRD ) Winter 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.( "77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77:00 77.00 77.00 77.( Summer 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.( 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.00 68.( Schedule: Mech.'vent set point ( TMVSP Winter 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 10( 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 10( Summer 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 10( 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 101 Schedule: Cooling set point ( TCOOL ) Winter 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.1 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.1 Summer 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.1 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.1 Surface A: 4980.00 Az: 0 T: 0 U: 0.02685 Abs: 0.500 EXT:-0 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Surface A: 1354.00 Az: 296 T: 90 U: 0.04556 Abs: 0.500 ExT:`0 Sgd to HOUSE -Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Surface A: 802.000 Az: 46 T: 90 U: 0.04556 Abs: 0.500 ExT: 0 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Surface A: 1336.00 Az: 206 T: 90 U: 0.04556 Abs: 0.500 ExT: 0 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Surface A: 1630.00 Az: 116 T: 90 U: 0.04556 Abs: 0.500 ExT: 0 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Surface A: 20.000 Az: 116 T: 90 U: 0.30873 Abs: 0.500 ExT: 0 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Glazing A: 186.000 Az: 296 T: 90 U: 0.38614 SHGCO: Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Glazing A: 192.000 Az: 46 T: 90 U: 0.38614 SHGCO: Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 Glazing A: 94.000 Az: 206 T: 90 U: 0.38614 SHGCO: Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 0.27429 SHGCC: 0.2593 0.27429 SHGCC: 0.2593 0.27429 SHGCC: 0.2593 0 31azing A: 356.000 Az: 46 T: 90 U: 0.38614 SHGCO: 0.27429 SHGCC: 0.25934 Sgd to HOUSE Type: 0 Fw: 1.000 Fs: 1.000 Sgd to HOUSE Type: 1 Fw: 1.000 Fs: 1.000 ?erim L: 424.000 Az: 0 T: 0 F2: 0.500 Abs: 0 ?erim L: 106.000 Az: 0 T: 0 F2: 0.550 Abs: 0 Kass: CERTILE Area: 880.000 BC -- type: 3 rsurf: 0 h: 1.500 Layer T: 0.042 vhc: 19.000 cond: 1.042 Layer T: 0.042 vhc: 19.000 cond: 1.042 BC -- type: 1 rsurf: 0 h: 0 Mass: TILE Area: 200.000 BC -- type: 3 rsurf: 0 h: 1.500 Layer T: 0.042 vhc: 19.000 cond: 1.042 Layer T: 0.042 vhc: 19.000 cond: 1.042 BC -- type: 3 rsurf: 0 h: 1.500 Mass: D_Bare Area: 996.400 BC -- type: 3 rsurf: 0 h: 1.300 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 BC -- type: 1 rsurf: 0 h: 0 Mass: D Covered . Area: 3985.60 BC -- type: 3 rsurf: 2.000 h: 0.361 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 Layer T: 0.073 vhc: 28.000 cond: 0.980 BC -- type: 1 rsurf: 0 h MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page I of 2) MF-IR Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall he considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: * §150(a): Minimum R-19 ceiling insulation. t/ § 150(b): Loose fill insulation manufacturer's labeled R-Value. ' § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does not apply to exterior mass walls). * § 150(d): Minimum R-13 raised floor insulation in framed floors. NIA § 150(1) : Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no t / neater than 2.0 erm/inch. V § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ✓ § 1 16-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls l/ I. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field-fabricated)have label with certified U-value, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § I50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. f § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. v 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: § 110-§ 113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § I50(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500 ): Pipe and tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internaVextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55° F insulated. 6. Piping insulated between heating source and indirect hot water tank. MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) MF-IR Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) ' § I50(m): Ducts and Fans (� 1. All ducts and plenums constructed, installed insulated, fastened, and sealed to comply with the ICBO 1997 UMC sections 601 and 603; ducts insulated to a minimum installed R-4 2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other duct closure system that meets the applicable requiremems of UL181, UL181A, or UL181B and other applicable specified tests for longevity given in §150(m).. 2. Exhaust fan systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. § 114: Pool and Spa Heating Systems and Equipment. 1. System is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filler and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas tired central furnaces, pool heaters, spa healers or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures: § 150(k)l .: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. § I50(k)2.: Rooms with a shower or bathtub must either have at leas(one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in § I50(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. MANDATORY MEASURES CHECKLIST (FORM MF-1R) STATE STANDARDS REQUIRE THE FOLLOWING MEASURES REGARDLESS OF THE COMPLIANCE APPROACH USED. THIS CHECKLIST IS INCORPORATED INTO THE PERMIT DOCUMENTS AND NOTED FEATURES MUST BE CONSIDERED BY ALL PARTIESN AS MINIMUM COMPONENT SPECIFICATIONS FOR THE MANDATORY MEASURES WHETHER INDICATED ELSEWHERE IN THE DOCUMENTS, DRAWINGS, OR ON THIS CHECKLIST ONLY. BUILDING ENVELOPE MEASURES: 150(a) MINIMUM R-19 CEILING INSULATION 150(bO LOOSE FILL INSULATION MANUFACTURER'S LABELED R—VALUE REQUIRED 150(c) MINIMUM R-13 WALL INSULATION IN WOOD FRAME WALLS OR EQUIVALENT U—VALUE IN METAL FRAME WALLS (DOES NOT APPLY TO EXTERIOR MASS WALLS) 150(d) MINIMUM R-13 RAISED FLOOR INSULATION IN FRAMED FLOORS 150(i) SLAB EDGE INSULATION (WATER ABSORPTION RATE NO GREATER THAN 0.3% WATER VAPOR TRANSMISSION RATE NO GREATER THAN 2.0 PERMS PER INCH. 118 TYPE AND FORM OF SPECIFIED INSULATION MUST MEET QUALITY STANDARDS. 116-17 FENESTRATION PRODUCTS, EXTERIOR DOORS, AND INFILTRATION/EXFILTRATION CONTROLS DOORS AND WINDOWS BETWEEN CONDITIONED AND CONDITIONED SPACES DESIGNED TO LIMIT AIR LEAKAGE. FENESTRATION PRODUCTS (EXCEPT FIELD FABRICATED) HAVE LABEL WITH CERTIFIED U—VALUE, SOLAR HEAT GAIN COEFFICIENT & INFILTRATION. EXTERIOR DOORS AND WINDOWS WEATHERSTRIPPED, ALL JOINTS AND PENETRATIONS CAULKED AND SEALED. 150(g) VAPOR BARRIERS MANDATORY IN CLIMATE ZONES 14 AND 16 ONLY 150(f) SPECIAL INFILTRATION BARRIER INSTALLED TO COMPLY WITH 151 (MEETS COMMISSION QUALITY STANDARDS) 150(e) INSTALLATION OF FIREPLACES, DECORATIVE GAS APPLIANCES AND GAS LOGS__. MASONRY AND FACTORY BUILT FIREPLACES TO HAVE CLOSEABLE METAL/GLASS DOORS OUTSIDE AIR INTAKE WITH DAMPER AND CONTROL FLUE DAMPER AND CONTROL NO CONTINUOUS BURNING GAS PILOT LIGHTS ALLOWED SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES 110-13 HVAC EQUIPMENT, WATER HEATERS, SHOWERHEADS & FAUCETS TO BE CERTIFIED 150(h) HEATING AND COOLING LOADS CALCULATED IN ACCORDANCE WITH ASHRAE, SMACNA, OR ACCA. 150(i) SETBACK THERMOSTAT ON ALL APPLICABLE HEATING OR COOLING SYSTEMS 1500) PIPE AND TANK INSULATION STORAGE GAS WATER HEATERS RATED WITH AN ENERGY FACTOR LESS THAN 0.58 MUST BE EXTERNALLY WRAPPED WITH INSULATION HAVING AN INSTALLED THERMAL RESISTANCE OF R-12 OR GREATER. FIRST FIVE FEET OF PIPES CLOSEST TO WATER HEATER TANK, NON —CIRCULATING SYSTEM, INSULATED (R-4 OR GREATER). ALL BURIED OR EXPOSED PIPING INSULATED IN RECIRCULATING SECTION OF H.W. SYSTEM. COOLING SYSTEM PIPING BELOW 55 DEGREES F., INSULATED. PIPING INSULATED BETWEEN HEATING SOURCE AND INDIRECT HOT WATER TANK. BACK—UP TANKS FOR SOLAR SYSTEM, UNFIRED STORAGE TANKS, OR OTHER INDIRECT HOT WATER TANKS HAVE R-12 EXTERNAL INSULATION OR R-16 COMBINED INTERNAL/EXTERNAL INSULATION. • 150(m) DUCTS AND FANS ALL DUCTS AND PLENUMS CONSTRUCTED, INSTALLED, FASTENED, AND SEALED TO COMPLY WITH ICBO 1997 U_M.C. SECTIONS 601 AND 603; DUCTS INSULATED TO A MINIMUM INSTALLED R-4.2 OR DUCTS ENCLOSED ENTIRELY WITHIN CONDITIONED SPACE. OPENINGS SHALL BE SEALED WITH MASTIC, TAPE, AEROSOL SEALANT OR OTHER DUCT CLOSURE SYSTEM THAT MEETS THE APPLICABLE REQUIREMENTS OF UL181,UL181A, OR UL181B AND OTHER APPLICABLE SPECIFIED TESTS FOR LONGEVITY GIVEN IN 150(m). 114 POOL AND SPA HEATING SYSTEMS AND EQUIPMENT SYSTEM IS CERTIFIED WITH 78% THERMAL EFFICIENCY, ON -OFF SWITCH, WEATHERPROOF OPERATING INSTRUCTIONS, NO ELECTRIC RESISTANCE HEATING AND NO PILOT LIGHT. SYSTEM INSTALLED WITH AT LEAST 36" OF PIPE BETWEEN FILTER AND HEATER FOR FUTURE SOLAR HEATING AND COVER FOR OUTDOOR POOLS AND SPAS. POOL SYSTEM HAS DIRECTIONAL INLETS AND A CIRCULATION PUMP TIME SWITCH. GAS FIRED CENTRAL FURNACES, POOL HEATERS, SPA HEATERS OR HOUSEHOLD COOKING APPLIANCES HAVE NO CONTINUOUSLY BURNING PILOT LIGHT. (EXCEPTION: NON -ELECTRICAL COOKING APPLIANCES W/ PILOT<150 BTU/hr) GRAVITY VENTILATING SYSTEMS SERVING CONDITIONED SPACE HAVE EITHER AUTOMATIC OR READILY ACCESSIBLE, MANUALLY OPERATED DAMPERS. EXHAUST FAN SYSTEM SHALL HAVE BACKDRAFT OR AUTOMATIC DAMPERS. LIGHTING MEASURES 150(k) LUMINAIRES FOR GENERAL LIGHTING IN KITCHENS SHALL HAVE LAMPS WITH AN EFFICIENCY OF 40 LUMENS/WATT OR GREATER FOR GENERAL LIGHTING CONTROLLED BY A SWITCH ON A READILY ACCESSIBLE LIGHTING CONTROL PANEL AT ENTRANCE TO TO KITCHEN. PROVIDE FLUORESCENT GENERAL LIGHTING (40 LUMENS PER WATT MIN.) IN KITCHEN(S) AND BATHROOMS (CONTAINING A TUB OR SHOWER). 150(k) ROOMS WITH A SHOWER OR BATHTUB TO HAVE AT LEAST ONE LUMINAIRE WITH AN EFFICIENCY OF 40 LUMENS PER WATT OR GREATER SWITCHED AT THE ENTRANCE TO THE ROOM (OR ALTERNATE ALLOWED IF RECESSED FIXTURE WITH INSULATION COVER APPROVED BY THE COMMISS►ON). WEATHERSTRIP EXTERIOR DOORS AND WINDOWS CAULK AND SEAL JOINTS AND PENETRATIONS TO UNCONDITIONED AREAS. MANUFACTURED DOORS AND WINDOWS TO BE CERTIFIED AND LABELED. EXHJAUST FANS NEED DAMPER CONTROLS FOR FIREPLACES: TIGHT -FITTING, CLOASEABLE METAL OR GLASS DOORS OUTSIDE AIR INTAKE W/ DAMPERS AND CONTROLS IN FIREPLACES LOCATED ON THE OUTSIDE WALLS OR OVER WOOD FLOORS FLUE DAMPERS AND CONTROLS NO CONTINUOUS BURNING GAS PILOTS INSULATE HEATING AND A.C. DUCTS AUTOMATIC SETBACK THERMOSTATS FOR HEATING AND COOLING SYSTEMS WRAP STORAGE TYPE WATER HEATERS W/ R-12 INSULATION INSULATE FIRST 5 FEET OF HOT WATER PIPES CLOSEST TO W.H. W/ R-4 INSULATION GAS COOKING APPLIANCES EQUIPPED W/ INTERMITTENT IGNITION DEVICES. USE FLUORESCENT FIXTURES FOR GENERAL LIGHTING IN KITCHEN AND BATHROOMS SLAB EDGE INSULATION SHOULD BE WATER AND VAPOR RESISTANT. MECHANICAL EQUIPMENT, W.H., SHOWER HEADS, AND FAUCETS MUST BE CERTIFIED BY C.E.C. COMPUTER MODEL COMPLIANCE REFER TO THE COMPUTER MODEL FOR SPECIFIC COMPLIANCE MEASURES E X T E R 1 0 R W A L L I N S U L A T 1 0 N EXTERIOR WALLS TO BE LOW MOISTURE (35% OR LESS ON A DRY WEIGHT BASIS) CONTENT WALL SPRAY CELLULOUS INSULATION FOR AN R—VALUE OF 20 IN 2 X 6 WALLS. THE WALL SPRAY CELLULOUS INSULATION TO BE "THERMOLOCK INCIDE PC INSULATION, OR EQUAL PRODUCT TO BE CERTIFIED BY THE E.PA AND U.S. DEPARTMENT OF AGRICULTURE TO PROVIDE CONTINUOUS AND LIFETIME PROTECTION AGAINST PEST INFESTATION. (PESTS ARE DEFINED AS COCKROACHES, ANTS, DRYWOOD TERMITES, SUBTERRAINIAN TERMITES, ETC_) A T T I C I N S U L A T I O N BLOWN —IN CELLULOSE INSULATION SHALL BE USED UNLESS AREA IS NOT ACCESSIBLE TO INSTALLER. BATTS INSULATION REQUIRES SUPPORT WIRES WHEN SPANNING SOFFITED AREAS. BLOWN INSULATION TO BE INSTALLED TO A DPTH OF 9 INCHES WHICH SETTLES TO 8 INCHES FOR AN R VALUE OF R-30. R-38 RATED INSULATION REQUIRES AN INSTALLATION OF 11.5 INCHES WHICH SETTLES TO 10 INCHES FOR R-38 RATING. R-38 RATED BATTS INSULATION REQUIRES TWO LAYERS. THE FIRST LAYER TP BE R-13 IN 2x4 BOTTOM CHORD TRUSS BAYS OR R-19 IN 2x6 BOTTOM CHORD BAYS. THE SECOND LAYER TO BE OF AN R—VALUE TO MEET THE TOTAL REQUIRED ATTIC INSULATION RATING. C R A W L S P A C E 0 R B A S E M E N T C E I L I N G MANUFACTURED TRUS—JOIST FLOOR ASSEMBLIES TO HAVE FULL 16' WIDE R-19 UNFACED BATT INSULATION TO ACHIEVE A FRICTION FIT. BATTS TO BE IN CONTACT WITH FLOOR SHTG. INSTALL WITH PROPERLY SIZED WIRE BATT HANGERS. NOTE: WHERE CONFINED CRAWL SPACE AREAS OCCUR; COVER SOIL WITH A 4—MIL CROSS LAMINATED POLYETHELYENE (SEAL ALL JOINTS AND TO CONCRETE OR MASONRY WITH 3M ACRYLIC BUILDERS SEALING TAPE). A I R S E A L I N G SEAL ALL PENETRATIONS IN TOP AND BOTTOM PLATES THAT PENETRATE THE THERMAL/PRESSURE ENVELOPE. THIS INCLUDES AROUND DOORS ANDF WINDOWS. FOAM SHALL BE GUN APPLIED, LOW EXPANSION, HANDIFOAM OR APPROVED EQUAL. SEAL FLUE PIPES TO SHEET METAL COLLARS WITH HIGH TEMPERATURE CAULK. ALL LARGE HOLES MUST BE ISOLATED WITH CAULK AND AND RIGID INSULATION WITH RIGID INSULATION (CUT TO FIT) AND CAULKING. IF VINYL WINDOWS ARE USED, SUBSTITUTE FIBERGLAS IN LIEU OF FOAM. H 0 U S E P R E S S U R E T E S T BLOWER DOOR PRESSURE TEST RESULTS MUST BE OUT AT 3.5 AIR CHANGES PER HOUR MAX. SET AT 50 PASCALS TEST PRESSURE_ ALL INTENTIONAL OPENINGS TO BE SEALED PRIOR TO TEST. (FIREPLACES, DRAINS, EXHAUST FANS, ETC.). SUBMIT TEST REPORT TO ARCHITECT FOR APPROVAL A I R D I S T R I B U T 1 0 N S Y S T E M ALL DUCT WORK TO BE SEALED WITH MASTIC. THIS INCLUDES TRANSVERSAL JOINTS AND TAKE— OFFS FOR BRANCH DUCTS ON TRUNK LINES. METAL TAPE TO BE USED TO SEAL UNIT PANEL AND FILTER CABINETS. USE ONLY U.1_181 A—P APPROVED METAL TAPE. PLUMBERS PUTTY TO BE USED TO SEAL REFRIGERANT LINES WHERE THEY ENTER COIL EVERY JOINT IN A FRAMED CAVITY RETURN MUST BE SEALED EG OSB TO CONCRETE, OSB TO OSB_ AIR DISTRIBUTION SYSTEM TO PASS DUCT BLISTER TEST. D U C T B L A S T E R T E S T MEASURED DUST LEAKAGE MUST BE LESS THAN 5 PERCENT OF THE HIGH SPEED FLOW RATE OF THE UNIT AT 2/10ths OF ONE INCH WATER COLUMN. (EXAMPLE: A 4 TON UNIT HAS A RATED AIRFLOW OF 1600 CFM = 400 CFM PER TON. THIS SYTEM REQUIRES 80 CFM OR LESS OF LEAKAGE). A MORE AGGRESIVE STANDARD STANDARD WOULD BE 37. OF THE LIVABLE AREA OF THE HOUSE. PRESURE TEST RESULTS TO BE SUBMITTED TO ARCHITECT FOR APPROVAL. M E C H A N I C A L FILTRATION / VENTILATION WHOLE HOUSE HEPA FILTRATION AND VENTILATION SYSTEM TO BE VENMAR HEPA 3000* OR APPROVED EQUAL BATHROOM FANS TO BE AS SPECIFIED ON ELECTRICAL PLANS. ELECTRICAL ALL RECESSED CANS TO BE LCAT. RATED (INSULATION CONTACT AIR —TIGHT) G E N E R A L N 0 T E S ALL SYSTEMS, EQUIPMENT AND/OR BUILDING COMPONENTS SHALL COMPLY WITH THE APPLICABLE MANUFACTURER PROVISIONS AND INSTALLATION PROVISIONS OF TITLE 24, PART 6. CH 2, SEC 111-119. ALL APPLIANCES IN COMPLIANCE WITH CALIFORNIA STANDARDS AND THE APPLIANCE EFFICIENCY REGULATIONS SHALL BE CERTIFIED BY THE MANUFACTURER. (TITLE 24. PART 6, CH 2, SEC 111) SPACE CONDITIONING EQUIPMENT TO MEET THE STANDARDS (TITLE 24, PART 6, CH 2, SEC 112) MANUFACTURED FENESTRATION PRODUCTS AND EXTERIOR DOORS SHALL HAVE AIR INFILTRATION RATES NOT EXCEEDING 0.3 CFM/SF OF WINDOW AREA, 0.3 CFM/SF OF RESIDENTIAL DOOR AREA, 0.3 CFM/SF OF NONRESIDENTIAL SINGLE DOOR AREA, AND 1.0 CFM/SF OF NON- RESIDENTIAL DOUBLE DOOR AREA. (TITLE 24, PART 6, CH 2, SEC 116) FENESTRATION PRODUCTS, OTHER THAN PRODUCTS WHICH ARE REMOVED AND REINSTALLED, SHALL HAVE A TEMPORARY LABEL, OR LABEL CERTIFICATE FOR SITE BUILT PRODUCTS, WHICH LISTS THE CERTIFIED U-FACTOR AND SHGC. AND CERTIFIES THAT APPICABLE LEAKAGE REQUIREMENTS ARE MET. (KYLE 24, PART 6, CH 2, SEC 116) FIELD MANUFACTURED FENESTRATION PRODUCTS AND EXTERIOR DOORS, OTHER THAN UNFRAMED GLASS DOORS AND FIRE DOORS, SHALL BE CAULKED BETWEEN THE FENESTRATION PRODUCTS OR EXTERIOR DOORS AND FIRE DOORS, SHALL BE CAULKED BETWEEN THE FENESTRATION PRODUCTS OR EXTERIOR DOOR AND THE BUILDING, AND SHALL BE WEATHER-STRIPPED. (CH 2, SEC 116) JOINTS AND OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL SOURCES OF AIR LEAKAGE SHALL BE CAULKED, GASKETED, WEATHER-STRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND EX -FILTRATION. (TITLE 24, PART 6, CH 2, SEC 117) INSULATION SHALL BE CERTIFIED BY THE MANUFACTURER, AS COMPLIANT WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL, TITLE 20, CH 4, ART. 3. (CH 2, SEC 118) ALL INSULATING MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF SECTION 707 OF THE UBC (CH 2, SEC 118) PORTIONS OF AIR DISTRIBUTION SYSTEMS. DUCTS AND PLENUMS WHICH CONVEY CONDITIONED AIR SHALL BE INSULATED TO A LEVEL OF NOT LESS THAN R-4.2 OR BE ENCLOSED ENTIRELY IN CONDITIONED SPACE. TITLE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) FACTORY -FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181 FOR DUCTS AND CLOSURE SYSTEMS, INCLUDING COLLARS, CONNECTORS AND SPLICES, AND BE UL LABELED. TITLE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150 (m) FACTORY -MADE FIBERGLASS AND FLEXIBLE DUCTS FOR FIELD FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181. ALL PRESSURE SENSITIVE TAPES, MASTICS, AEROSOL SEALANTS. OR OTHER CLOSURE SYSTEMS USED FOR INSTALLING FIELD -FABRICATED DUCT SYSTEMS SHALL MEET THE APPLICABLE STANDARDS OF UL 181A, OR UL 181B, TIRE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) SEALANTS SHALL COMPLY WITH UL 181, UL 181A, OR UL 1818, AND BE NONTOXIC AND WATER RESISTANT. TITLE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) SEALANTS FOR INTERIOR APPLICATIONS SHALL PASS ASTM TESTS C 731 AND D 2202. TITLE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) SEALANTS FOR EXTERIOR APPLICATIONS SHALL PASS ASTM TESTS C731, C732 AND D2202 TITLE 24, PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) SEALANTS AND MESHES SHALL BE RATED FOR EXTERIOR USE. TITLE 24, PART 6. CH 3, SEC 124 AND CH 7, SEC 150(m) DRAW -BANDS SHALL BE EITHER STAINLESS STEEL WORM -DRIVE HOSE CLAMPS OR IN - RESISTANT NYLON DUCT TIES. HAVING A MINIMUM TENSILE STRENGTH OF 150 POUNDS, AND SHALL BE TIGHTENED AS RECOMMENDED BY THE MFGR. (CH 3, SEC 124 AND CH 7, SEC 150(m) JOINTS AND SEAMS OF DUCT SYSTEMS AND THEIR COMPONENETS OTHER FACTORY OR FIELD FABRICATED) SHALL NOT BE SEALED WITH CLOTH BACK RUBBER ADHESIVE DUCT TAPES UNLESS SUCH TAPE IS USED IN COMBINATION WITH MASTIC AND DRAW BANDS. TITLE 24. PART 6, CH 3, SEC 124 AND CH 7, SEC 150(m) INSULATED FLEXIBLE DUCT PRODUCTS MUST INCLUDE LABELS, IN MAXIMUM INTERVALS OF 3 FEEEET, SHOWING THE THERMAL PERFORMANCE R-VALUE FOR THE DUCT INSULATION ITSELF (EXCLUDING AIR FILMS, VAPOR BARRIERS OR OTHER DUCT COMPONENTS) AND THE INSTALLED THICKNESS OF THE INSULATION. TITLE 14, PART 6, CH 3, SEC 124(e) AND CH 7, SEC 150(m) INSULATION FOR PIPING AND DUCTS, SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND. INSUATION EXPOSED TO WEATHER SHALL BE SUITABLE FOR OUTDOOR SERVICE. TITLE 24. PART 6, CH 3, SEC 123, AND 124(h); CH 7, SEC 15O0) AND 150(m) certificate of compliance: residential (FORM CF-1 R) PAGE 3 OF 3 compliance statement This certificate of compliance lists the building features and perlbrmance speakations needed to comply with Title 24. parts 1 and 6 of tre California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual wilh overall design responsibility. The uhdersigned reeog Ize that compliance using dud searM and TXVs (or Commission approved equivalent) requires Installer testing and oertification and field verification by an approved HERS rater. Desww or Owner (per Business and Professions Code) �+ C DOCUMENTATION AUTHOR Name: Gerald Shmgleton ��� �, �7t,�/li^ ' Name: Title / Firm SHINGLETON-ARCH \ Q Title / Firm Address: 743 GLEN HILL LANE v � 't Tess: BEUMONT. CA 92223 ljJ Z Telephone: Ph. 909-845{902 * 0 i� {1� DATE* } Licenca.Mmher Q f\ C-83921Arc rter3l /f .. ENFOCEMENT AGENCY Name: Title / Firm Address: Telephone: Licence Number SIGNATURE: Gerald Shingleton SHINGLETOWARCHITECT 743 GLEN HILL LANE BEUMONT, CA 92223 Ph. 909-845-5902 C-8392 (Architect) EXTERIOR AIR FILM 3/8" STUCCO ONE COAT 1 INCH E.P.S. FOAM INSULATION 2 LAYERS TYPE "D" BLDG. PAPER .375" CDX PLYWOOD SHTG. 1/2" GYPSUM BOARD VENEER 2 X 6 STUDS AT 16" O.C. R-21 FIBERGLASS INSULATION INTERIOR AIR FILM TOTAL ADJUSTED 'R" VALUES CAVITY (Rc) FRAME (R1) 0.17000 0.1700 0.0075 0.0075 4.000 4.000 0.0600 0.0600 0.4700 0.4700 0.4500 0.4500 5.445 21.00 .... 0.680 0.680 26.8375 11.2825 Rc Rf FRAMING ADJUSTMENT CALCULATION 1 F% 1 F% 1 X 1— — + — X — = TOTAL "U" VALUE — = TOTAL "R" VALUE Rc 100 Rf 100 "U" 1 15 1 15 1 X 1— — + — X — = 0.04496 — = 22.24 26.8375 100 1 1.2825 100 .04496 EXTERIOR WALL ASSEMBLY DETAIL CAVITY (Rc) FRAME (R1) 3.50" AND GREATER AIR SPACE 0.800 0.800 EXTERIOR AIR FILM 0.1700 0.1700 ROOFING MATERIAL 0.4400 0.4400 BUILDING PAPER (FELT) 0.060 0.060 0.50 INCH SHTG. 0.620 0.620 R-38 FIBERGLASS INSULATION 38.00 38.00 R-11 FIBERGLASS INSULATION 11.00 .... 2x4 BOTTOM CHORD FRAMING ..... 3.465 1 /2" GYPSUM BOARD 0.450 0.450 INTERIOR AIR FILM 0.610 0.610 �n �u "�v ^lT T BARRIER SHEET ATOTAL ADJUSTED 'R" VALUES 52.15 BARRIER UNDERSIDE OF SHTG. Rc FRAMING ADJUSTMENT CALCULATION 45.145 Rf 1 F% 1 F% 1 X 1— — + X — = TOTAL "U" VALUE — = TOTAL "R" VALUE Rc 100 [w- 100 'lull 1 7 1 7 1 X 1— — + 15 X — = 0.01938 — = 51.60 52.15 100 45.145 100 0.01938 EXTERIOR ROOF ASSEMBLY DETAIL n No I III-I�, SMOOTH SKIN EXTRUDED z I I II t I II II_I I POLYSTYRENE R-7 I II - INSULATION BOARD -I III- (PROTECT FROM PHYSICAL Eilf DAMAGE AND ULTRAVIOLET III I Ell, LIGHT EXPOPSURE.) I II 411 IINOTE; INSULATION WATER = II I I=11 ABSORPTION RATE TO BE II I I I I II III_I1=�, NO GREATER THAN 2.0 PERMS i=1ii -1I1-III-i PER INCH. NOTE: INSULATION IS NOT REQUIRED AT SLAB EDGE BETWEEN CONDITIONED AND ATTACHED UNCONDITIONED ENCLOSED SPACE, COVERED PATIO OR STEPS. TYPICAL SLAB EDGE INSULATION SINGLE FAMILY W/ MULTIPLE WATER HEATERS DHW-2A Ji✓(v ejutJ 7 -0 Project Title Date Note: In addition to this form, a DHW-1 Water Heating Worksheet must also be submitted to document water heater type(s). Single Family Project Data 1. No. of different water heater types: 2. Total conditioned floor area: No. of Heater Heaters Type # Manufacturer & Model No. 3a. �_ #1 3b. #2 3c. #3 4. ' ` Total Number of Water Heaters 5. Standard Recovery Load: 1 r2= 64 from Table 6-5 based on line 2 6. Recovery Load Per Heater. T b (line 5 = line 4); enter on DHW-1, line la for each Heater Type, and complete calculation through line 2d. 7. Proposed Energy Use, Heater #1: 21f, (from DHW-1 line 2d, Heater #1) x (line 3a) 8. Proposed Energy Use, Heater #2: (from DHW-I line 2d, Heater #2) x (line 3b) 9. Proposed Energy Use, Heater #3: (from DHW-1 line 2d, Heater #3) x (line 3c) 10. Total Proposed Energy Use: (tine 7 + line 8 + line 9) 11. Standard Energy Use: �� from Table 6-5 based on line 2 Compliance 12. Prescriptive Compliance: Line 10 must be equal to or less than line 11. See Section 6.1 and Chapter 3 in the Residential Manual for details. Compliance Forms August 2001 A-9 WATER HEATING WORKSHEET DHW-1 Project Title IaO Date -7 - 0' - It Z No. of Different Water Heater Types: r Total No. of Water Heaters: Conditioned Floor Area (CFA): �a fe Notes: For single family dwellings with multiple water heaters, also submit DHW-2A. For multi -family buildings, also submit DHW-213. Heater Type # Data A. Water Heater Type (check one) Zt Storage Gas _ Large Storage Gas _ Storage Electric _ Storage Heat Pump _ Instantaneous Gas _ Instantaneous Electric _ Indirect Gas Ma nufacturer anufacturer A O 411111 C. Model No. v D. Energy Factor C (P E. Gallons F. Pilot Btu/hr 'J2, PLV G. Thermal Eff. 1 H. Auxiliary Input (check one or both) _ Wood Stove Solar 1. Distribution System (check one) Standard Hot Water Recovery (HWR) _ Point of Use (POU) Pipe Insulation (PI) _ Parallel Piping (PP) _ Recirculation: No Control _ Recirculation: Timer _ Recirculation: Temp. _ Recirculation: Time/Temp. _ Recirculation: Demand _ HWR + Recirculation: Demand PI + Recirculation: Demand Energy Use Calculation 1 a. Standard Recovery Load (from Table 6-5, DHW-2A or 2B) 1 b. Distribution Credit/Penalty (from Table 6-6 or 6-7) lc. Solar Fraction (from Table 6-9) 1 d. Solar Energy Credit (lc x la) le. Adjusted Recovery Load ( Ot'-' (la- lb- Id) 2a. Basic Energy Use (p, 7 (from Table 6-8, DHW-213 or 3) 2b. Wood Stove Boiler Credit Factor (from Table 6-10) 2c. Wood Stove Boiler Credit (2a x 2b) 2d. Proposed Energy Use (2a - 2c) 3. Standard Energy Use 5 (from Table 6-5) Heater Type # Data A. Water Heater Type (check one) _ Storage Gas _ Large Storage Gas _ Storage Electric _ Storage Heat Pump _ Instantaneous Gas _ Instantaneous Electric _ Indirect Gas B. Manufacturer Heater Type # Data A. Water Heater Type (check one) _ Storage Gas _ Large Storage Gas _ Storage Electric _ Storage Heat Pump _ Instantaneous Gas _ Instantaneous Electric _ Indirect Gas B. Manufacturer C. Model No. C. Model No. D. Energy Factor D. Energy Factor E. Gallons E. Gallons _ F. Pilot Btu/hr F. Pilot Btu/hr _ G. Thermal Eff. G. Thermal Eff. H. Auxiliary Input (check one or both) _ Wood Stove Solar I. Distribution System (check one) _ Standard _ Hot Water Recovery (HWR) Point of Use (POU) Pipe Insulation (PI) _ Parallel Piping (PP) _ Recirculation: No Control _ Recirculation: Timer _ Recirculation: Temp. _ Recirculation: Time/Temp. _ Recirculation: Demand _ HWR + Recirculation: Demand PI + Recirculation: Demand Energy Use Calculation Ia. Standard Recovery Load (from Table 6-5, DHW-2A or 213) 1 b. Distribution Credit/Penalty (from Table 6-6 or 6-7) lc. Solar Fraction (from Table 6-9) 1d.Solar Energy Credit (lc x la) 1 e. Adjusted Recovery Load (la- lb- Id) 2a. Basic Energy Use (from Table 6-8, DHW-213 or 3) 2b. Wood Stove Boiler Credit Factor (from Table 6-10) 2c. Wood Stove Boiler Credit (2a x 2b) 2d. Proposed Energy Use (2a - 2c) 3. Standard Energy Use (from Table 6-5) H. Auxiliary Input (check one or both) _ Wood Stove Solar 1. Distribution System (check one) _ Standard _ Hot Water Recovery (HWR) Point of Use (POU) Pipe Insulation (PI) _ Parallel Piping (PP) _ Recirculation: No Control _ Recirculation: Timer _ Recirculation: Temp. _ Recirculation: Time/Temp. _ Recirculation: Demand _ HWR + Recirculation: Demand PI + Recirculation: Demand Energy Use Calculation Ia. Standard Recovery Load (from Table 6-5, DHW-2A or 213) 1 b. Distribution Credit/Penalty (from Table 6-6 or 6-7) lc. Solar Fraction (from Table 6-9) 1d.Solar Energy Credit (lc x la) 1 e. Adjusted Recovery Load (1a- lb- Id) 2a. Basic Energy Use (from Table 6-8, DHW-2B or 3) 2b. Wood Stove Boiler Credit Factor(from Table 6-10) 2c. Wood Stove Boiler Credit (2a x 2b) 2d. Proposed Energy Use (2a - 2c) 3. Standard Energy Use (from Table 6-5) 4. For Prescriptive Compliance (one water heater per dwelling): Line 2d must not exceed Line 3 Compliance Forms August 2001 A-8 ao 00 Q3U-0oUcfl Sho ergy Xatvd1hq i*r APPROVAL RATINGS AND CERTIFICATION All models comply with: ANSI Z21.10.1 or ANSI Z21.10.3 ASHRAE/IES 90.1 b-1999 1990 NAECA BOCA AND CEC FSGH-30 & 40, FSG 50, 75 & 100 comply with SCAQMD natural gas NOx rule 1121 or 1146.2 when ordered with suffix (SMR) R-99. All models are approved for use in combined appliance applications. FEATURES FOAM INSULATION — Minimizes radiant heat loss. DIP TUBE — Carries inlet water deep into tank. THERMOSTAT — Designed for long service life_ Safety shutoff provided. Propane models have built-in filter. GLASS -LINED TANK — Glass, specifically developed by A.O. Smith for water heaters, is fused to steel at 1600*F., providing corrosion protection for years of dependable use. ANODE — Tank -mounted, screw -in anode for longer tank life. BURNER — All steel, multiport burner for improved combustion efficiency. FSGT has a stainless steel burner. R99 models supplied with low NOx burner to meet SCAQMD regulations. DRAIN VALVE — Non-metallic valves. FACTORY SUPPLIED TEMPERATURE & PRESSURE RELIEF VALVE STANDARD. DRAFT DIVERTER — Supplied with screw down anchor tabs for secure connection to the top cover. NON-LINTING ENERGY SAVING PILOT FSG-75 and 100 feature A.O. Smith's patented "cross- fire" flue design for improved combustion efficiency. ENERGY SAVER GAS RESIDENTIAL WATER HEATERS FSG, FSGL, FSGH & FSGT oEste ir �,�eVtATP.R\ Y L us� ((�I (75 AND 100 GALLON Clw4sq MODELS) aRno4� 6 YEAR LIMITED TANK WARRANTY If the tank should leak any time during the first 6 years, under the terms of the warranty, A. O. Smith will furnish a replacement heater. Installation, labor, handling and local delivery are extra. When used commercially, warranty is for 1 year. THIS OUTLINE IS NOT A WARRANTY. For complete information, consult the written warranty or A. O. Smith Water Products Company_ Warranty does not apply to product installed outside of the United States of America or its territorial possessions and Canada. Revised July 2001 (Reviewed January 2002) A 713.1 n - " ENERGY SAVER GAS GLASS -LINED WATER HEATER i II6PLLR61MALEYNNIMN TANUU NAROf®6161�. II/ ��Cd-D NER UNION INLET PIPE DRAFT r NLEr VALVE HOOD PLUG Vut ANODE IIA ET HOT WATER DIP TUBE OUTLET PPE PLUG ANODE \ •TEMPERATURE AND PRESSURE RELIEF 31C NPT i - \ COO ,I i INLET A VALVE �/ I RELIEF VALVE OUTLET - DRAINLINE RELIEF \ / RAT= AND 3/4" NPT / nsuATxw ITA,IND PLATEBAFFIUE A C- GAS SUPPLY TYPICAL 1&" NPT B �- PIPE INSTALLATION GAS INLET 4" VAN MANUAL DRAIN CAS SHUTOFF VALVE ` VALVE A INLET/OUTLET 1" ON 75 GAL. MODELS TOP 1 1 1/4" ON 100 GAL MODELS. -- THERMOSTAT (zj i 16" ON 75 AND 100 GAL MODELS. GROUND LINTER JOINT UNION TEMPERATURE ADJUSTING DIAL DIRT DRAIN VALVE ' 9LEG CAP7GAS FLOOR CRIW FRONT VIEW TOP VIEW N.ET OUTER DOOR M'�L CODES NATURAL GAS I PROPANE GAS A B C 1st Hr. Height Height Approx_ BTU Gal./Hr.* BTU GaIJHr.' Model Rating Energy Gal. Vent Input Recovery Input Recovery Plus Less Ship. Wt No. Gals. Factor Cap. Size Per Hr. 90"F Rise Per Hr. 90"F Rise Diverter Diverter Dia. (Lbs.) ENERGY SAVER MODELS FSG-30 56 .57 30 3" 12 000 32.7 30 000 30.7 59 55 114 15 3/4 105 FSG-40 65 .56 40 3" 1 32,000 1 32.7 1 30,000 30.7 1 57 1 531/4 1 18114 119 "FSG-50 1 78 1 .55 J 50 1 3" L40,000 1 40.9 1 37,000 37.9 1 601/4 1 561/2 1 201/4 153 ENERGY SAVER LOWBOY MODELS FSGL-30 1 54 1 .57 1301 3" 1 40.000 1 40.9 1 37.000 1 37.9 1 47 1/2 1 43 3/4 118 1!4 114 FSGL-40 1 65 1 .55 1 40 1 3" 40,000 1 40.9 37,000 37.9 A 51 47114 201/4 131 ENERGY SAVER HIGH INPUT MODELS -FSGH-30 66 .56 30 3" 40,000 40.9 37,000 37.9 61 1/4 57 112 15 3/4 122 "FSGH 40 7fi 55 40 1 3" 40,000 1 40.9 37,000 37.9 59 1/4 55 1/2 1 18 1/4 1 128 "FSGH-50 78 .53 50 1 3" 40,000 1 40.9 37,000 37.9 601/4 561/2 1 201/4 1 153 ENERGY SAVER VERY HIGH INPUT MODELS FSGTAO 77 .57 38 1 4" 1 50,000 1 512 41 000 1 48.1 J 59 54 314 1 20 114 1 130 FSGT-50 100 .54 48 1 4" 1 60 000 61:4 - 60 1/2 56 1!4 20 1/4 164 FSG-75 75 4" 76,000 79.8 76,000 79.8 61 57 251l2 271 FSG-100 - 100 4" 78,000 81.9 78,000 81.9 681/2 65 26112 1 352 NOTE: To compensate for the effects of high altitude area above 2.000 feet, recovery capacity should be reduced approximately 4% each 1,000 feet above sea level. ALL DIMENSIONS IN INCHES. ' Recovery capacities are based on DOE method of test. (100"F rise for 75 & 100 gallon heaters). " Natural gas input for R-99 models is 38,000 BTU/hr. Recovery capacity is 38.9 GPH at 90°F temp. rise. SUGGESTED SPECIFICATIONS Water Heater(s) shall be Model No. as manufactured by A. O. SMITH, or an approved equal. Heater(s) shall be glass -lined, gas -fired, equipped to bum , design certified to meet the latest ANSI Standard. Heater(s) shall have a 1st hour delivery rating of gallons, an input rating of BTU/hr., and a recovery capacity of GPH at "F temperature rise, and an energy factor of or greater. Gas control shall regulate the gas supply to main and pilot burners. Heater(s) shall have a maximum working pressure of 150 psi, a nominal storage tank capacity of gallons with a 314" tapping for relief valve installation and a rigidly supported anode rod for maximum cathodic protection. All internal surfaces of the heater(s) exposed to water shall be glass -lined with an alkaline borosilicate composition fused -to - steel. Heater(s) shall also be equipped with an automatic shutoff device to shutoff entire gas supply in event of excessive temperature in tank. Heater(s) shall also be equipped with a draft hood. Tank shall be foam insulated. Outer jacket shall have a baked enamel finish. Heater shall have a 6 year limited warranty as outlined in the written warranty in a residential installation, (1 year in a commercial installation). Fully illustrated instruction manual to be included. Heater(s) shall comply with the "National Appliance Energy Conservation Act (NAECA) of 1990". A.O. Smith Water Products Co., Inc. On Line www.hotwatercom For Technical Information and Automated Fax Service, Phone: B00.527-1953 A. O. Smith Water Products Company Irving, TX A Division of A. O. Smith Corporation A. O. Smith Corporation reserves the right to make product changes or improvements at any time without notice. A 713.2 (9 N- U. Jmlm L.OIp., zuvI