Loading...
BRES2015-0302 Title 24BUILDING ENERGY ANALYSIS REPORT PROJECT: Ratpack Residence 53-525 Humbolt Blvd. La Quinta, CA 92253 Project Designer: Gordon Stein 55-053 Sorrel Court Indio, CA 92201 (760) 773-4488 Report Prepared by: Tim Scott Scott Design and Tit 24, Inc, 77085 Michia Palm Desert, C"^� (760) 200-47� No SgFE�/nl 7',4 T� 'i �ON °b "°'"bey: RECEIVED Date: AUG 06 2015 8/5/2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the Cafrfomia Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.7 by EnergySoff User Number. 6712 ID: TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 18 Form MF-1 R Mandatory Measures Summary 20 HVAC System Heating and Cooling Loads Summary 24 Room Load Summary 29 Room Heating Peak Loads 34 Room Cooling Peak Loads 41 I EnergyPro 6.7 by EnergySoft Job Number ID: User Number 6712 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1R-PRF-01 Page 1 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml GENERAL INFORMATION 01 Project Name Ratpack 02 Calculation Description Title 24 Analysis 03 Project Location 53-525 Humbolt Blvd. 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Newly Co str to 3 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 7656 Number of Zones 7 16 Slab Area (ft2) 7656 & SAFETY DEM. Number of Stories 1 18 Addition Cond. Floor Area N/A Natural Gas Available Yes r2O Addition Slab Area (ft2) N/A CT (>� Glazing Percentage (%) 46.9% COMPLIANCE RESULTS BYAL 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/Pr'verification by a certifiedHERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 05 06 07 08 Energy Usk (k?dV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating;, . 5.26 9.10 -3.84 -73.0% S ce Coolly ' , 121.26 113.17 8.09 6.7% ,. IA ntilation 0.71 0.71 0.00 0.0% Wate ting 3.35 3.74 -0.39 -11.6% Qhotoyoltai set ---- 0.00 0.00 ---- Compliancq_,F ergy Total 130.58 126.72 3.86 3.0% Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Page 2 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (0I1) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirely in conditioned space Domestic Hot Water System Verifications: - • -None -Al - ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 164.95 161.09 3.86 2.3% ' includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Ratpack 7656 1 5 7 5 1 Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Page 3 of 15 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 master Conditioned HVAC 1 mstr1 862 9 DHW Sys 1 great room Conditioned HVAC 2 grt2 1882 9 DHW Sys 1 family Conditioned HVAC 3 fam3 1462 9 DHW Sys 1 guest-4 Conditioned HVAC 44 900 9 DHW Sys 1 lounge Conditioned HVAC 44 850 9 DHW Sys 1 3 Conditioned HVAC 55 850 9 1 DHW Sys 1 2 Conditioned HVAC 55 1850 1 9 1 DHW Sys 1 ca- 10E:RT:c'>,., 1"nC., P-# F F2 S- P R Q V I D E R Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml Page 4 of 15 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) 80d Wall master R-21 Wall (W.21.2x6.16) 80 Front 150 90 170d Wall master R-21 Wall (W.21.2x6.16) 170 Left 720 126.8 90 260d Wall master R-21 Wall (W.21.2x6.16) 260 Back 440 135 90 350d Wall master R-21 Wall (W.21.2x6.16) 350 Right 900 106.2 90 Roof R-38 master R-38 Roof Attic 862 80d Wall 2 great room R-21 Wall (W.21.2x6.16) 80 Front 700 266.3 90 170d Wall 2 great room R-21 Wall (W.21.2x6.16) 170 Left 450 208.93 90 260d Wail 2 great room R-21 Wall (W.21.2x6.16) 260 Back 1125 483.29 90 350d Wall 2 great room R-21 Wall (W.21.2x6.16) 350 Right 450 114.7 90 Roof R-38 2 great room R-38 Roof Attic 1882 80d Wall 3 family R-21 Wall (W.21.2x6.16) 80 Front 900 75 90 170d Wall 3 family R-21 Wall (W.21.2x6.16) 170 Left 1125 233 90 260d Wall 3 family R-21 Wall (W.21.2x6.16) 260 Back 150 90 350d Wall 3 family R-21 Wall (W.21.2x6.16) 350 Right 1806 217.5 90 Roof R-38 3 family R-38 Roof Attic 1462 80d Wall 4 guest-4 R-21 Wall (W.21.2x6.18) 80 Front 525 90 170d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 170 Left 735 230 90 260d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 260 Back 525 88 90 350d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 350 Right 735 102 90 Roof R-38 4 guest-4 R-38 Roof Attic 900 80d Wall 5 lounge R-21 Wall (W.21.2x6.16) 80 Front 650 215 90 260d Wall 5 lounge R-21 Wall (W.21.2x6.16) 260 Back 650 236.5 90 Roof R-38 5 lounge R-38 Roof Attic 850 80d Wall 6 3 R-21 Wall (W.21.2x6.16) 80 Front 560 88 90 170d Wall 5 3 R-21 Wall (W.21.2x6.16) 170 Left 700 227.973 90 350d Wail 5 3 R-21 Wall (W.21.2x6.16) 350 Right 500 131 90 Roof R-38 6 3 R-38 Roof Attic 850 170d Wall 6 2 R-21 Wall (W.21.2x6.16) 170 Left 720 108 90 260d Wall 6 2 R-21 Wall (W.21.2x6.16) 260 Back 500 108 90 350d Wall 6 2 R-21 Wall (W.21.2x6.16) 350 Right 500 87.992 90 Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml Roof R-38 7 2 R-38 Roof Attic 850 CFI R-PRF-01 Page 5 of 15 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Attic Roofmaster Ventilated 3 0.62 0.83 No Yes Attic great room Attic Roofgreat room Ventilated 3 0.62 0.83 No Yes Attic family Attic Rooffamily Ventilated 3 0.62 0.83 No Yes Attic guest-4 Attic Roofguest-4 Ventilated 3 0.62 0.83 No Yes Attic lounge Attic Rooflounge Ventilated 3 0.62 0.83 No Yes Attic 3 Attic Roof3 Ventilated 3 0.62 0.83 No Yes Attic 2 Attic Roof2 Ventilated 3 0.62 0.83 No Yes � Fi F-� 11-4, S. - ...alCERTS P R C-) V I E R Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaiCERTS inc, CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xm1 CFIR-PRF-01 Page 6 of 15 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (W) U-factor SHGC Exterior Shading D3 Window 170d Wall (Left-170) 10.6 3.0 1 31.8 0.34 0.25 Insect Screen (default) D2 Window 170d Wall (Left-170) ---- ---- 1 41.0 0.34 0.25 Insect Screen (default) 22 Window 170d Wail (Left-170) ---- ---- 1 54.0 0.48 0.19 Insect Screen (default) 21 Window 260d Wall (Back-260) --- ---- 1 135.0 0.48 0.19 Insect Screen (default) D1 Window 350d Wall (Right-350) - - ---- 1 30.2 0.34 0.25 Insect Screen (default) 20 Window 350d Wall (Right-350) - - -__ 1 64.0 0.48 0.19 Insect Screen (default) C2 Window 350d Wall (Right-350) ---- 1 12.0 0.34 0.25 Insect Screen (default) 58 Window 80d Wall 2 (Front-80) 21.5 10.0 1 215.0 0.48 0.19 Insect Screen (default) G4 Window 80d Wall 2 (Front-80) ---- ---- 1 51.3 0.34 0.25 Insect Screen (default) G3 Window 170d Wall 2 (Left-170) ---- ---- 1 18.0 0.34 0.25 Insect Screen (default) G2 Window 170d Wall 2 (Left-170) ---- ---- 1 18.8 0.34 0.25 Insect Screen (default) 23 Window 170d Wall 2 (Left-170) 7.0 11.0 1 77.0 0.48 0.19 Insect Screen (default) E2 Window 170d Wall 2 (Left-170) 6.3 15.1 1 95.1 0.34 0.25 Insect Screen (default) 24 Window 260d Wall 2 (Back-260) 21.5 11.0 1 236.5 0.38 0.23 Insect Screen (default) G1 Window 260d Wall 2 (Back-260) ---- --- 1 52.0 0.34 0.25 Insect Screen (default) E1 Window 260d Wall 2 (Back-260) 12.9 15.1 1 194.8 0.34 0.25 Insect Screen (default) G6 Window 350d Wall 2 (Right-350) ---- ---- 1 27.4 0.34 0.25 Insect Screen (default) G5 Window 350d Wall 2 (Right-350) ---- -- 1 63.3 0.34 0.25 Insect Screen (default) D51 Window 350d Wall 2 (Right-350) --- 1 24.0 0.35 0.30 Insect Screen (default) 01 Window 80d Wall 3 (Front-80) 1 55.0 0.94 0.49 Insect Screen (default) D6 Window 80d Wall 3 (Front-80) ---- ---- 1 20.0 0.48 0.19 Insect Screen (default) 04 Window 170d Wall 3 (Left-170) ---- -- 1 178.0 0.48 0.19 Insect Screen (default) A Window 170d Wall 3 (Left-170) ---- ---- 1 55.0 0.94 0.49 Insect Screen (default) C1 Window 350d Wall 3 (Right-350) --- 1 16,5 0.34 0.25 Insect Screen (default) 13 Window 350d Wall 3 (Right-350) --- 1 24.0 0.48 0.19 Insect Screen (default) B Window 350d Wall 3 (Right-350) ---- ---- 1 177.0 0.34 0.25 Insect Screen (default) 50 Window 170d Wall 4 (Left-170) 8.0 10.0 1 80.0 0.48 0.19 Insect Screen (default) 46 Window 170d Wall 4 (Left-170) 15.0 10.0 1 150.0 0.48 0.19 Insect Screen (default) 45 Window 260d Wall 4 (Back-260) ---- ---- 1 88.0 0.48 0.19 Insect Screen (default) Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xm1 CF1R-PRF-01 Page 7 of 15 44 Window 350d Wall 4 (Right-350) --• 1 43.0 0.48 0.19 Insect Screen (default) 43 Window 350d Wall 4 (Right-350) ---- ---- 1 35.0 0.48 0.19 Insect Screen (default) 51 Window 350d Wall 4 (Right-350) ---- ---- 1 24.0 0.34 0.25 Insect Screen (default) 582 Window 80d Wall 5 (Front-80) 21.5 10.0 1 215.0 0.48 0.19 Insect Screen (default) 242 Window 260d Wall 5 (Back-260) 21.5 11.0 1 236.5 0.48 0.19 Insect Screen (default) 37 Window 80d Wall 6 (Front-80) 8.8 10.0 1 88.0 0.48 0.19 Insect Screen (default) 38 Window 170d Wall 5 (Left-170) 15.0 10.0 1 150.0 0.48 0.19 Insect Screen (default) 42 Window 170d Wall 5 (Left-170) 7.9 10.0 0.987 78.0 0.48 0.19 Insect Screen (default) 35 Window 350d Wall 5 (Right-350) ---- ---- 1 78.0 0.48 0.19 Insect Screen (default) 36 Window 350d Wall 5 (Right-350) -- 1 53.0 0.48 0.19 Insect Screen (default) 32 Window 170d Wall 6 (Left-170) ---- ---- 1 78.0 0.48 0.19 Insect Screen (default) F Window 170d Wall 6 (Left-170) ---- ---- 1 30.0 0.34 0.25 Insect Screen (default) 28 Window 260d Wall 6 (Back-260) 10.8 10.0 1 108.0 0.48 0.19 Insect Screen (default) 27 Window 350d Wall 6 (Right-350) 5.3 10.0 1 53.0 0.48 0.19 Insect Screen (default) 26 Window 350d Wall 6 (Right-350) 10.8 10.0 0.324 35.0 0.48 0.19 Insect Screen (default) ('AICERTS, t.-I S R 0, V Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CFI R-PRF-01 Page 8 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up D3 10 0A 10 10 0 0 0 0 0 0 0 0 0 58 10 0.1 10 10 0 0 0 0 0 0 0 0 0 23 18 0.1 18 18 0 0 0 0 0 0 0 0 0 E2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 24 10 0.1 10 10 0 0 0 0 0 0 0 0 0 E1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 50 10 0.1 10 10 0 0 0 0 0 0 0 0 0 46 10 0.1 10 10 0 0 0 0 0 0 0 0 0 582 10 0.1 10 10 0 0 0 0 0 0 0 0 0 242 10 0.1 10 10 0 0 0 0 0 0 0 0 0 37 10 0.1 10 10 0 0 0 0 0 0 0 0 0 38 10 0.1 10 10 0 0 0 0 0 0 0 0 0 42 10 0.1 10 10 0 0 0 0 0 0 0 0 0 28 10 0.1 10 10 0 0 0 0 0 0 0 0 0 27 8 0.1 8 8 0 0 0 0 0 0 0 0 0 26 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CFI R-PRF-01 Page 9 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat room Attic Roofs Wood Framed Ceiling in. O.C. none 0,644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooffamily Attic Roofs Wood Framed Ceiling in. O.G. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic Roofguest-4 Attic Roofs Wood Framed Ceiling in. O.0 none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooflounge Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-0517:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1 R-PRF-01 Page 10 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Covered Slab master 862 100 None 0.8 No Covered Slab 2 great room 1882 88 None 0.8 No Covered Slab 3 family 1462 166 None 0.8 No Covered Slab 4 guest-4 900 121 None 0.8 No Covered Slab 5 lounge 850 55 None 0.8 No Covered Slab 6 3 850 83 None 0.8 No Covered Slab 7 2 850 83 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 112 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 --- --- --- --- -- -- Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Pagel 1 of 15 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC 1 mstrl Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC 2 grt2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC 3 fam3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC 55 Other Heating and Cooling System Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 9 80 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-NO2022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1 R-PRF-01 Page 12 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13.1 16.7 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 3 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 4 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 5 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 150 Required Required Required Cooling Component 3-hers-cool Required 150 Required Required Required Cooling Component 4-hers-cool Required 150 Required Required Required Cooling Component 5-hers-cool Required 150 Required Required Required Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack- Stein- 15.xmi CF1 R-PRF-01 Page 13 of 15 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 1-hers-dist Air Distribution System 2 LowLICod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 2-hers-dist Air Distribution System 3 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 3-hers-list Air Distribution System 4 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 4-hers-dist Air Distribution System 5 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 5-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 2-hers-dist Required 6.0 Required Not Required Not Required Not Required Air Distribution System 3-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 4-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 5-hers-list Required 6.0 Required Not Required Not Required Not Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Registration Number: 215-NO2022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CFI R-PRF-01 Page 14 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0,58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 HVAC Fan 5-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 121.56 0.25 Default 0 Required COOLING VENTILATION 01 02 03 04 05 Name Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans WH Fan 1 61;• : c 4,"`< 32 1 WH Fan 2 61 '• 4'.' 0. 459 32 1 WH Fan 3 61 = 0.6245'r"N k'132 1 WH Fan 4 61 0. 9 V 1 32 1 WH Fan 5 61 0.52459 32 1 PROJECT NOTES The Madison Club Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Page 15 of 15 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Z;r1'-5C'Vz i' Company: Signature Date: Scott Design and Title 24, Inc. 2015-08-05 17:14:55 Address: CEA/HERS Certification Identification (if applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature'. Tim Scott Company: Date Signed: Scott Design and Title 24, Inc. 2015-08-05 17:14:55 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by Ca10ERT5. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml Page 1 of 15 GENERAL INFORMATION 01 Project Name Ratpack 02 Calculation Description Title 24 Analysis 03 Project Location 53-525 Humbolt Blvd. 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 80 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 7656 15 Number of Zones 7 16 Slab Area (ft2) 7656 17 Number of Stories 1 18 Addition Cond. Floor Area NIA 19 Natural Gas Available Yes 20 Addition Slab Area (ft) N/A 21 Glazing Percentage (%) 46.9% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft -yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 5.26 9.10 -3.84 -73.0% Space Cooling 121.26 113.17 8.09 6.7% IAQ Ventilation 0.71 0.71 0.00 0.0% Water Heating 3.35 3.74 -0.39 -11.6% Photovoltaic Offset ---- 0.00 0.00 --- Compliance Energy Total 130.58 126.72 3.86 3.0% Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins CF1 R-PRF-01 Page 2 of 15 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Ducts located entirety In conditioned space Domestic Hot Water System Verifications: --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on -site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)' 164.95 161.09 3.86 2.3% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Ratpack 7656 1 5 7 5 1 Registration Number: 215-No202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Page 3 of 15 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 master Conditioned HVAC 1 mstrl 862 9 DHW Sys 1 great room Conditioned HVAC 2 grt2 1882 9 DHW Sys 1 family Conditioned HVAC 3 fam3 1462 9 DHW Sys 1 guest-4 Conditioned HVAC 44 900 9 DHW Sys 1 lounge Conditioned HVAC 44 850 9 DHW Sys 1 3 Conditioned HVAC 55 850 9 DHW Sys 1 2 Conditioned HVAC 55 850 9 DHW Sys 1 C. CaICERTS In. Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Page 4 of 15 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) 80d Wall master R-21 Wall (W.21.2x6.16) 80 Front 150 90 170d Wall master R-21 Wall (W.21.2x6.16) 170 Left 720 126.8 90 260d Wall master R-21 Wall (W.21.2x6.16) 260 Back 440 135 90 350d Wall master R-21 Wall (W.21.2x6.16) 350 Right 900 106.2 90 Roof R-38 master R-38 Roof Attic 862 80d Wall 2 great room R-21 Wall (W.21.2x6.16) 80 Front 700 266.3 90 170d Wall 2 great room R-21 Wall (W.21.2x6.16) 170 Left 450 208.93 90 260d Wall 2 great room R-21 Wall (W.21.2x6.16) 260 Back 1125 483.29 90 350d Wall 2 great room R-21 Wall (W.21.2x6.16) 350 Right 450 114.7 90 Roof R-38 2 great room R-38 Roof Attic 1882 80d Wall 3 family R-21 Wall (W.21.2x6.16) 80 Front 900 75 90 170d Wall 3 family R-21 Wall (W.21.2x6.16) 170 Left 1125 233 90 260d Wall 3 family R-21 Wall (W.21.2x6.16) 2Ei0 Back 150 90 350d Wall 3 family R-21:Wall (W.21.2x6.16) 350 Right 1806 217.5 90 Roof R-38 3 family R-3KRobf Attic 1462 80d Wall 4 guest-4 R'-21 Wall (W.21.2x6.16) 80 Front 525 90 170d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 170 Left 735 230 90 260d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 260 Back 525 88 90 350d Wall 4 guest-4 R-21 Wall (W.21.2x6.16) 350 Right 735 102 90 Roof R-38 4 guest-4 R-38 Roof Attic 900 80d Wall 5 lounge R-21 Wail (W.21.2x6.16) 80 Front 650 215 90 260d Wall 5 lounge R-21 Wall (W.21.2x6.16) 260 Back 650 236.5 90 Roof R-38 5 lounge R-38 Roof Attic 850 80d Wall 6 3 R-21 Wall (W.21.2x6.16) 80 Front 560 88 90 170d Wall 5 3 R-21 Wall (W.21.2x6.16) 170 Left 700 227.973 90 350d Wall 5 3 R-21 Wall (W.21.2x6.16) 350 Right 500 131 90 Roof R-38 6 3 R-38 Roof Attic 850 170d Wall 6 2 R-21 Wall (W.21.2x6.16) 170 Left 720 108 90 260d Wall 6 2 R-21 Wall (W.21.2x6.16) 260 Back 500 108 90 350d Wall 6 2 R-21 Wall (W.21.2x6.16) 350 Right 500 87.992 90 Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015.08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi Roof R-38 7 2 R-38 Roof Attic 850 CF1 R-PRF-01 Page 5 of 15 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Attic Roofmaster Ventilated 3 0.62 0.83 No Yes Attic great room Attic Roofgreat room Ventilated 3 0.62 0.83 No Yes Attic family Attic Rooffamily Ventilated 3 0.62 0.83 No Yes Attic guest-4 Attic Roofguest-4 Ventilated 3 0.62 0.83 No Yes Attic lounge Attic Rooflounge Ventilated 3 0.62 0.83 No Yes Attic 3 Attic Roof3 Ventilated 3 0.62 0.83 No Yes Attic 2 Attic Roof2 Ventilated 3 0.62 0.83 No Yes �iCaICERI I mo:'� "-. Registration Number: 215-N02022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-0517:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1 R-PRF-01 Page 6 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U factor SHGC Exterior Shading D3 Window 170d Wall (Left-170) 16.6 3.0 1 31.8 0.34 0.25 Insect Screen (default) D2 Window 170d Wall (Left-170) --- ---- 1 41.0 0.34 0.25 Insect Screen (default) 22 Window 170d Wall (Left-170) ---- -- 1 54.0 0.48 0.19 Insect Screen (default) 21 Window 260d Wall (Back-260) -- -- 1 135.0 0.48 0.19 Insect Screen (default) D1 Window 350d Wall (Right-350) --- ---- 1 30.2 0.34 0.25 Insect Screen (default) 20 Window 350d Wall (Right-350) -- --- 1 64.0 0.48 0.19 Insect Screen (default) C2 Window 350d Wall (Right-350) --- --- 1 12.0 0.34 0.25 Insect Screen (default) 58 Window 80d Wall 2 (Front-80) 21.5 10.0 1 215.0 0.48 0.19 Insect Screen (default) G4 Window 80d Wall 2 (Front-80) ---- ---- 1 51.3 0.34 0.25 Insect Screen (default) G3 Window 170d Wall 2 (Left-170) ---- ---- 1 18.0 0.34 0.25 Insect Screen (default) G2 Window 170d Wall 2 (Left-170) ---- ---- 1 18.8 0.34 0.25 Insect Screen (default) 23 Window 170d Wall 2 (Left-170) 7.0 11.0 1 77.0 0.48 0.19 Insect Screen (default) E2 Window 170d Wall 2 (Left-170) 6.3 15.1 1 95.1 0.34 0.25 Insect Screen (default) 24 Window 260d Wall 2 (Back-260) 21.5 11.0 1 236.5 0.38 0.23 Insect Screen (default) G1 Window 260d Wall 2 (Back-260) - 1 52.0 0.34 0.25 Insect Screen (default) E1 Window 260d Wall 2 (Back-260) 12.9 15.1 1 194.8 0.34 0.25 Insect Screen (default) G6 Window 350d Wall 2 (Right-350) ---- --- 1 27.4 0.34 0.25 Insect Screen (default) G5 Window 350d Wall 2 (Right-350) --- --- 1 63.3 0.34 0.25 Insect Screen (default) D51 Window 350d Wall 2 (Right-350) - - 1 24,0 0.35 0.30 Insect Screen (default) 01 Window 80d Wall 3 (Front-80) ---- ---- 1 55.0 0.94 0.49 Insect Screen (default) D6 Window 80d Wall 3 (Front-80) ---- ---- 1 20.0 0.48 0.19 Insect Screen (default) 04 Window 170d Wall 3 (Left-170) ---- ---- 1 178.0 0.48 0.19 Insect Screen (default) A Window 170d Wall 3 (Left-170) ---- ---- 1 55.0 0.94 0.49 Insect Screen (default) C1 Window 350d Wall 3 (Right-350) ---- ---- 1 16.5 0.34 0.25 Insect Screen (default) 13 Window 350d Wall 3 (Right-350) --- 1 24.0 0.48 0.19 Insect Screen (default) B Window 350d Wall 3 (Right-350) ---- ---- 1 177.0 0.34 0.25 Insect Screen (default) 50 Window 170d Wall 4 (Left-170) 8.0 10.0 1 80.0 0.48 0.19 Insect Screen (default) 46 Window 170d Wall 4 (Left-170) 15.0 10.0 1 150.0 0.48 0.19 Insect Screen (default) 45 Window 260d Wall 4 (Back-260) ---- ---- 1 88.0 0.48 0.19 Insect Screen (default) Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi C F 1 R-PRF-01 Page 7 of 15 44 Window 350d Wall 4 (Right-350) --- - 1 43.0 0.48 0.19 Insect Screen (default) 43 Window 350d Wall 4 (Right-350) - - -- 1 35.0 0.48 0.19 Insect Screen (default) 51 Window 350d Wall 4 (Right-350) ---- ---- 1 24.0 0.34 0.25 Insect Screen (default) 582 Window 80d Wall 5 (Front-80) 21.5 10.0 1 215.0 0.48 0.19 Insect Screen (default) 242 Window 260d Wall 5 (Back-260) 21.5 11.0 1 236.5 0.48 0.19 Insect Screen (default) 37 Window 80d Wall 6 (Front-80) 8.8 10.0 1 88.0 0.48 0.19 Insect Screen (default) 38 Window 170d Wall 5 (Left-170) 15.0 10.0 1 150.0 0.48 0.19 Insect Screen (default) 42 Window 170d Wall 5 (Left-170) 7.9 10.0 0.987 78.0 0.48 0.19 Insect Screen (default) 35 Window 350d Wall 5 (Right-350) ---- ---- 1 78.0 0.48 0.19 1 Insect Screen (default) 36 Window 350d Wall 5 (Right-350) ---- ---- 1 53.0 0.48 0.19 Insect Screen (default) 32 Window 170d Wall 6 (Left-170) ---- ---- 1 78.0 0.48 0.19 Insect Screen (default) F Window 170d Wall 6 (Left-170) --- ---- 1 30.0 0.34 0.25 Insect Screen (default) 28 Window 260d Wall 6 (Back-260) 10.8 10.0 1 108.0 1 0.48 0.19 Insect Screen (default) 27 Window 350d Wall 6 (Right-350) 5.3 10.0 1 53.0 0.48 0.19 Insect Screen (default) 26 Window 350d Wall 6 (Right-350) 10.8 10.0 0.324 35.0 1 0.48 0.19 Insect Screen (default) '"'- a R T Inc,, Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1 R-PRF-01 Page 8 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up D3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 58 10 0.1 10 10 0 0 0 0 0 0 0 0 0 23 18 0.1 18 18 0 0 0 0 0 0 0 0 0 E2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 24 10 0.1 10 10 0 0 0 0 0 0 0 0 0 E1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 50 10 0.1 10 10 0 0 0 0 0 0 0 0 0 46 10 0.1 10 10 0 0 0 0 0 0 0 0 0 582 10 0.1 10 10 0 0 0 0 0 0 0 0 0 242 10 0.1 10 10 0 0 0 0 0 0 0 0 0 37 10 0.1 10 10 0 0 0 0 0 0 0 0 0 38 10 0.1 10 10 0 0 0 0 0 0 0 0 0 42 10 0.1 10 10 0 0 0 0 0 0 0 0 0 28 10 0.1 10 10 0 0 O 0 0 0 0 0 0 27 8 0.1 8 8 0 0 0."' 0 0 0 0 0 0 26 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 215-NO2022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CFi R-PRF-01 Page 9 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-value Assembly Layers • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofgreat room Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooffamily Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofguest4 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Rooflounge Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof3 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Registration Number: 215-N0202265B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 ' - 10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CFI R-PRF-01 Page 10 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Covered Slab master 862 100 None 0.8 No Covered Slab 2 great room 1882 88 None 0.8 No Covered Slab 3 family 1462 166 None 0.8 No Covered Slab 4 guest-4 900 121 None 0.8 No Covered Slab 5 lounge 850 55 None 0.8 No Covered Slab 6 3 850 83 None 0.8 No Covered Slab 7 2 850 83 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 112 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R-value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 — --- --- --- Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14;55 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1R-PRF-01 Page 11 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC 1 mstr1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC 2 grt2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fary2 Air Distribution System 2 HVAC 3 fam3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC 55 Other Heating and Cooling System Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-NO202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml CF1 R-PRF-01 Page 12 of 15 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13.1 16.7 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 3 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 4 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool Cooling Component 5 SplitAirCond 13.1 16.7 Zonally Controlled Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 150 Required Required Required Cooling Component 3-hers-cool Required 150 Required Required Required Cooling Component 4-hers-cool Required 150 Required Required Required Cooling Component 5-hers-cool Required 150 Required Required Required Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14;55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Description: Title 24 Analysis Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Input File Name: Ratpack-Stein-15.xml CFI R-PRF-01 Page 13 of 15 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsinAll Sealed and tested 8 Conditioned zone None Air Distribution System 1-hers-dist Air Distribution System 2 LowLICod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 2-hers-list Air Distribution System 3 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 3-hers-dist Air Distribution System 4 DuctSInAll Sealed and tested 8 Conditioned zone None Air Distribution System 4-hers-dist Air Distribution System 5 DuctslnAll Sealed and tested 8 Conditioned zone None Air Distribution System 5-hers-list HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handier Air Distribution System 1-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 2-hers-dist Required 6.0 Required Not Required Not Required Not Required Air Distribution System 3-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 4-hers-dist Required 6.0 Required Not Required Not Required Not Required --- Air Distribution System 5-hers-disc Required 6.0 Required Not Required Not Required Not Required HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation DatelTime: 17:08, Wed, Aug 05, 2015 Calculation Description: Title 24 Analysis Input File Name: Ratpack- Stein- 15.xm1 CF1 R-PRF-01 Page 14 of 15 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 HVAC Fan 5-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 121.56 0.25 Default 0 Required COOLING VENTILATION 01 02 03 04 05 Name Cooling Vent CFM Cooling Vent Watts/CFM Total Wafts Number of Fans WH Fan 1 61 0.52459 32 1 WH Fan 2 61 0.52459 32 1 WH Fan 3 61 0,52459 32 1 WH Fan 4 61 0.52459 32 1 WH Fan 5 61 0.52459 32 1 PROJECT NOTES The Madison Club Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: Ca10ERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-05 17:10:12 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 CF1 R-PRF-01 Page 15 of 15 Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2015-08-05 17:14:55 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott Company: Date Signed: .. Scott Design and Title 24, Inc. 2015-08-05 17:14:55,� Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 (760) 200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CalCERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12 1 I RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ F)dsting+ Addition/Alterabon Date 8/5/2015 Project Address 53-525 Humbolt Blvd. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,6 Addition n/a # of Units 1 INSULATION Construction Type Cavi Area (ft) Special Features Status Roof Wood Framed Attic R 38 7,656 Cool Roof New Wall Wood Framed R 21 12, 627 New Slab Unheated Slab -on -Grade - no insulation 7,656 Perim = 696' New Demising Wood Framed R 13 4,160 New Door Opaque Door - no insulation 0 New FENESTRATION Orientation Area(ft2) Total Area: 3,589 Glazing Percentage: 46.9 % U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor: Exterior Shades 0.45 Status Left (S) 126.9 0.340 0.25 10.0 none Bug Screen New Left (S) 107.8 0.340 0.25 none none Bug Screen New Left (S) 310.0 0.480 0.19 none none Bug Screen New Rear (IM 223.0 0.480 0.19 none none Bug Screen New Right (N) 350.4 0.340 0.25 none none Bug Screen New Right (N) 297.0 0.480 0.19 none none Bug Screen New Front (E) 518.0 0.480 0.19 10.0 none Bug Screen New Front (E) 51.3 0.340 0.25 none none Bug Screen New Left (S) 77.0 0.480 0.19 18.0 none Bug Screen New Rear (IM 236.5 0.380 0.23 10.0 none Bug Screen New Rear (IM 52.0 0.340 0.25 none none Bug Screen New Rear (VIM 194.8 0.340 0.25 10.0 none Bug Screen New Right (N) 24.0 0.350 0.30 none none Bug Screen New Front (E) 55.0 0.940 0.49 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.7 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC 1 mstr Ducted Ducted Conditioned 8.0 New HVAC 2 grt Ducted Ducted Conditioned 8.0 New HVAC 3 lam Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Storage Gas 50 0.68 All Pipes Ins New Ene Pro 6.7 by EnerqySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 18 of 48 1 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Ratpack Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ E)dsting+ Addition/Alteration Date 81512015 Project Address 53-525 Humbolt Blvd. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 7,656 Addition Na # of Units 1 INSULATION Construction Type Area Cavity (ff) Special Features Status FENESTRATION I Total Area: 3,589 Glazing Percentage: 46.9 New/Altered Average U-Factor: Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades 0.45 Status Front (E) 20.0 0.480 0.19 none none Bug Screen New Left (S) 55.0 0.940 0.49 none none Bug Screen New Left (S) 458.0 0.480 0.19 10.0 none Bug Screen New Rear (W) 344.5 0.480 0.19 10.0 none Bug Screen New Right (N) 53.0 0.480 0.19 8.0 none Bug Screen New Right (N) 35.0 0.480 0.19 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.7 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.7 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC 4 Ducted Ducted Conditioned 8.0 New HVAC 5 Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro, 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 ID: Pa - a 19 of 46 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the rmmnlinnre nnnrnnrh aced F.rrentinm mnv annly_ Review the respective code section for more information Building Envelope Measures: § 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain § 110.6(a)5: Coefficient SHGC , and infiltration that meets the requirements of § 10-111 a . § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the § 110.8(i): installation of a cool roof is specified on the CF1R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-value. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U- § 150.0(c): factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- § 150.0(q): factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is § 150.0(e)1B: equipped with a readily accessible, operable, and tight -fitting er or a combustion -air control device. § 150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside § 150.0(e)2: of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation § 110.3(c)5: valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified § 150.0(h)l: in 150. 2. Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any § 150.0(h)3A: dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped §150.00)1A: with insulation having an installed thermal resistance of R-12 or greater. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external §150.00)1B: insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.06)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary 1 Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating § 150.00)2C: systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) § 150.0(n)3: or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m) l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other § 150.0(m)3-6: requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic § 150.0(m)7: dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers § 150.0(m)8: except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, § 150.0(m)9: sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)l l: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling § 150.0(m)15: capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with § 150.0(o)IA: Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary 1 Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction § 110.4(b)1 • and return lines, or built-up connections for future solar heating § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run onl_v during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § 150.0(k)lA• Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply § 150.0(k)1B: with the applicable provisions of § 150.0 The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1 C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. § 150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable § 150.0(k)1F: requirements of § 150.0 § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor fimction if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it fimctions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)211 fimctions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150. 2. § 150.0(k)2L• A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to 110.9, and complies with all other applicable requirements in 150. k 2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory, have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below, and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing fimction and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the followin methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the fimcMionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9C• For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply § 150.0(k)9D: with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141:0. § 150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 through 110.1 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building o'ect and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of § 110.10(c): interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system- §110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: firture solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". il 1 1 I I I J i HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 8/5/2015 System Name HVAC 1 mstr Floor Area 862 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 861 Return Vented Lighting Return Air Ducts Return Fan Ventilation 129 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 16,928 1,231 453 19,305 Total Output (Btuh) 89,000 0 Output Btuhfs 103.2 245 230 Cooling System 0 0 Output per System 59,000 5,7 44 3,291 129 6,315 Total Output Btuh 59,000 2,943 245 1 26,125 4,523 -2,943 Total Output Tons 4.9 230 Total Output (Btuhfs 68•4 Total Output s on 175.3 23,136 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACC760/58PH" l 10 48,523 0 89,000 89,000 Jan 1 AM Airflow cfmfs 2•32 Airflow (cfmfTon) 406.8 Outside Air (%) 6•5 % Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 48,523 0 Outside Air (cfmfs ) 0.15 Note: values above given at ARI.conoldons Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 129 cf n 72 OF 70 OF 112 OF 112 OF Heating Coil Supply Fan 112 OF 2,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 73/60OF 74/60OF 51 /50OF Outside Air -A V- ETA 129 chn Supply Fan Cooling Coil 52 150 OF 2,000 cfrn 48.5 % ROOMNNW Mo 70 / 58 °F 70 / 58 OF Enen7yPro 6.7 by EnergySoff User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 24 of 48 1 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 8/5/2015 System Name HVAC 2 grt Floor Area 1,882 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,259 Return Vented Lighting Return Air Ducts Return Fan Ventilation 282 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 36,337 2,688 851 33,239 Total Output (Btuh) 89,000 0 Output Btuhfs 47.3 0 0 Cooling System 0 0 Output per System 59,000 12,618 5,497 282 13,820 Total Output Btuh) 59,000 2,943 8,185 -2,943 Total Output (Tons) 4.9 01 0 Total Output (Btuhfsgft) 31.3 Total Output s on 382.8 51,898 44,115 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACC760/58PH-110 47,738 3,415 89,000 Airflow (cfm/s 1.06 Airflow cfmfTon) 406.8 Outside Air % 14-1 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 47,738 3,415 89,000 Outside Air cfnVsgft 0.15 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 282 cfm 72 OF 67 OF 109 OF 109 OF I 0 r' G Supply Fan Heating Coil 2,000 cfrn 109 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 178 OF 76163 OF 77 / 63 OF 55 / 54 OF Outside Air 282 cFm Supply Fan Cooling Coil 55 / 54 OF 2,000 cfm %.3 % ROOM 70/60OF 70/60OF 4 0- .0 — ',-] J EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 25 of 48 I 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 8/5/2015 System Name HVAC 3 fam Floor Area 1,462 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,712 Return Vented Lighting Return Air Ducts Return Fan Ventilation 219 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 29,770 2,088 841 33,833 Total Output (Btuh) 89,000 0 O ut Btuhls 60.9 431 402 Cooling System 0 0 Output per System 59,000 9,755 4,825 219 10,692 Total Output (Btuh 59,000 2,943 6,913 -2,943 Total Output (Tons) 4.9 431 402 Total Output (Stuh/sgft) 40.4 Total Output s on 297.4 1 43,330 42,385 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACC760/58PH-110 48,331 1,784 89,000 Airflow (cfm/sgft) 1.37 Airflow (cfm/Ton) 406.8 Outside Air (%) 11.0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 48,331 1,784 89,000 Jan 1 AM Outside Air (cfm/s 0.15 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 219 cfcfmHeating 72 OF 68 OF 110 OF 110 OF 10 LTIBA Coil Supply Fan 2,000 cfm 110 OF ROOMjog 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling peak 112 l 78 OF 75 l 62 OF 76 / 62 OF 53 / 52 OF Outside Air 219 ctrn Supply 1 Fan Cooling Coil 2,000 cfm 70 / 59 OF 54 / 52 OF 53.0% ROOM 70 159 OF EnergyPro 6.7 by EnefgySoft User Number. 6712 RunCode: 2015-08-05T20:29.00 !D. Page 26 of 48 i 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Ratpack Residence 8/5/2015 System Name Floor Area HVAC 4 1,750 ENGINEERING CHECKS SYSTEM LOAD Number of S tams 1 COIL CFM Total Room Loads 2,062 Return Vented Lighting Return Air Ducts Return Fan Ventilation 263Ll Supply Fan Supply Air Ducts COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 33,409 2,500 1,020 39,870 Total Output (Btuh) 89,000 0 Output Btuh/s 50.9 483 474 Cooling System 0 0 Output per System 59,000 5,280 263 12,788 Total O ut (Btuh) 59,000 -2,943 Total Output (Tons) 4.9 474 Total Output (Btuh/sgft) 33•7 TOTAL SYSTEM LOAD 7,780 Total Output s on 355.9 48,989 50,663 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACC760/58PH-110 47,983 2,919 89,000 Airflow cf nls 1.14 Airflow cf n/Ton) 406.8 Outside Air (%) 13.1 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 47,983 2,919 89,000 Outside Air (cfrn/sgft) 0.15 Note: values above given at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 109 OF 109 OF Outside Air 263 cfm Heating Coil Supply Fan 109 OF 2,000 cfrn -- ROOM 72 OF 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/63OF 77/63OF 55/53OF Outside Air 263 cfm Supply Fan Cooling Coil 55 154 OF AL 2,000 cfm 55.5 "/o ROOM 70160 OF 4— — 4 L 70 / 60 OF EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-0ti45T20:29:00 ID: Page 27 of 48 1 1 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Ratpack Residence Date 8/5/2015 System Name HVAC 5 Floor Area 1,700 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,790 Return Vented Lighting Return Air Ducts Return Fan Ventilation 255 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 29,424 2,428 915 35,981 Total Output (Btuh) 89,000 0 Output Btuh/s 52.4 426 428 Cooling System 0 0 Output per System 59,000 11,343 5,217 255 12,429 Total Output (Btuh 59,000 2,943 426 44,563 7,645 -2,943 Total Output (Tons) 4.9 428 Total Output (Btuhlsgft) 34•7 Total Output s on 345.8 46,322 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow(eft) 2,000 Carrier 24ACC760/58PH-110 48,022 2,736 89,000 Airflow cfrnls ) 1.18 Airflow cf nrron) 406.8 Outside Air (%) 12.8 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 48,022 2,736 89,000 Outside Air cfm/sgft) 0.15 Note: values above viven at ARI conditions Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of HeatingPeak 26 OF Outside Air 255 cfrn 72 OF -4-- A 67 OF 109 OF 109 OF G LEHI��� Heating Coil Supply Fan 2,000 cfm A 4 109 OF Room 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62OF 77/63OF 54/53OF Outside Air �a --- -4 r w 255 corn Supply Fan Cooling Coil 55153 OF 2,000 cfrn 55.1 % ROOM 70 ! 60 OF 70 / 60 OF EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 ID: Page 28 of 48 ROOM LOAD SUMMARY Ratpack Residence 1 81512015 HVAC 1 mstr 862 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible 1 master Master Bedroom 1 861 16,928 1,231 861 16,928 1,231 453 J9,305 PAGE TOTAL TOTAL* 861 16,928 1,231 453 19,305 861 16,928 1,231 453 19,305 Total includes ventilation load for zonal systems. EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 1D: Page 29 of 48 I ROOM LOAD SUMMARY Project Name Date Ratpack Residence 81512015 System Name Floor Area HVAC 2 9ft 1,882 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible great room Great Dining Ki chen 1 Z 259 36,3371 Z 688 Z 25 36,3371 Z 688 851 33, 239 PAGE TOTAL TOTAL* for zonal 2,2591 36,3371 Z 688 651 33,239 27259 F 36,3371 2,6881 851 33,239 I EnerayPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-08-05T20:29:00 ID. Page 30 of 48 1 ROOM LOAD SUMMARY I Ratpack Residence 8/5/2015 System Name Floor Area HVAC 3 fam 1,462 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible family Family Entry Hidden Mc 1 1,712 29,7701 2,088 1,7121 29,7701 Z088 841 33,833 PAGE TOTAL TOTAL' ' Total includes ventilation load for 1,712 29,770 Z088 841 33,833 1,7121 29,7701 Z 088 841 33,833 I Enen7yPro 6.7 by EnergvSolt User Number. 6712 RunCode: 2015-08-05T20.29.00 10: Page 31 of 48 ROOM LOAD SUMMARY Project Name Date Ratpack Residence 81512015 System Name Floor Area HVAC 4 1,750 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible guest-4 Guest Rooms 1 1,112 18,020 1,285 1,112 18,020 1,285 580 2Z683 lounge Lounge room 1 950 15,389 1,214 950 15,389 1,214 440 17,187 PAGE TOTAL TOTAL' ` Total includes ventilation load for Z 062 33,4091 Z 500 1,0201 39,870 2, 062 33,4091 2,5001 1,020 39,870 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 32 of 48 1 I ROOM LOAD SUMMARY Project Name RatDack Residence HVAC 5 ROOM LOAD SUMMARY ROOM COOLING PEAK Zone Name Room Name Mult. CFM Sensible Latent 3 Suite 3 1 975 16,034 1,214 2 Suite 2 1 814 13,390 1,214 PAGE TOTAL TOTAL* " Total includes ventilation load for zonal systems. 81512015 Floor Area 1,700 COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent CFM Sensible 975 16,034 1,214 496 19,502 814 13,390 1,214 419 16,479 1,790 29,424 Z 428 915 35,981 1, 790 29,424 Z 428 915 35,9811 IEnergvPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID_ Page 33 of 48 1 1 I ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 862.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 862.0 R-21 Wall (W..21.2x6.16) 1,842.0 be LowE METAL .34/.25 115.0 opp LowE METAL .48/.19 253.0 Slab -On -Grade Perim = 100.0 'R-13 Wall 452.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 862 X Schedule Air Sensible Area Fraction U-Value AT OF Btu/hr 46 = 1,031 46 ❑ 5,847 46 = 1,799 46 = 5,586 46 = 3,358 0 c 0 = = = = = = = = = = = = = = = = = = = = = = = = = Page Total 17,620 / 60 ] X 46 = 1,685 AT X 0.0260 X X X 0.0690 X X 0.3400 X 0.4800 X X 0.7300 X X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.266 Ceiling Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 19,305 EneWPro 6.7 by EnergySoft User Number. 6712 RunCode. 2015-08-05T20:29:00 ID: Page 34 of 48 1 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Floor Area 1,882.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 1,882.0 X 0.0260 1,651.8 X 0.0690 292.0 X 0.4800 520.7 X 0.3400 236.5 X 0.3800 24.0 X 0.3500 perm = 88.0 X 0.7300 721.0 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 1,882 X 9.00 X 0.266 Area Ceiling Height ACH AT *F Btu/hr = Z251 = 5,243 = 6,447 = 8,144 = 4,134 = 386 = Z955 = 0 = = = = = = = = = 29,560 46 = 3,678 R-38 Roof Attic X 46 R-21 Wall (W.21.2x6.16) X 46 opp LowE METAL .481..19 X 46 fx LowE METAL .34/.25 X X 46 dr LowE METAL ..38/.23 46 Double Metal Tinted X 46 Slab -On -Grade X 46 *R-13 Wall X 0 X X X X X X X X X X X X X X X X X X X X X X X Page Total / 60 ] X AT Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,239 EneWPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05 0:29.00 ID: Page 35 of 48 ROOM HEATING PEAK LOADS Project Name Date Ratpack Residence 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Family Entry Hidden Kitchen Time of Peak Jan 1 AM Floor Area 1,462.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U-Value AT °F Btu/hr R-38 Roof Attic 1,462.0 X 0.0260 X 46 = 1,749 R-21 Wall (W.21.2x6.16) 3,455.5 X 0.0690 X 46 = 10,968 Custom Entry Door 110.0 X 0.9400 X 46 = 4,756 opp LowE METAL .481.19 222.0 X 0.4800 X 46 = 4,902 fx LowE METAL .341.25 193.5 X 0.3400 X 46 = 3,026 Slab -On -Grade perim = 166.0 X 0.7300 X 46 = 5,574 "R-13 Wall 822.0 X 0.1020 X 0 = 0 X X = X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 30,975 Infiltration•[ f.00 X 1.064 X 1,462 X 9.00 X 0.266 / 60 ] X 46 = 2,857 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,833 EnergyPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 36 of 48 ROOM HEATING PEAK LOADS Project Name Ratpack Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Rooms Time of Peak Floor Area 900.0 ft2 Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 72 OF Conduction Area U-Value R-38 Roof Attic R-21 Wall (W.21.2x6.16) opp LowE METAL .481..19 fx LowE METAL .34/.25 Slab -On, -Grade 'R-13 Wall 900.0 2,100.0 396.0 24.0 perim = 121.0 6W.0 0.0260 0.0690 0.4800 0.3400 0.7300 0.1020 AT °F 8/5/2015 Jan 1 AM 26 OF Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total L Infiltration•[ 1.00 X 1.064 X 900 X 9.00 X 0.266 / 60 ] X 46 = Schedule Air Sensible Area Ceiling Height ACH AT Fraction Btu/hr 1,076 6,665 8,744 375 4,063 0 20, 924 1, 759 TOTAL HOURLY HEAT LOSS FOR ROOM 22, 683 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T2 .29:0 ID: Page 37 of 48 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Lounge room Floor Area 850.0 flz Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 850.0 X R-21 Wall (W.21.2x6.16) 848.5 X opp LowE METAL .48/.19 451.5 X Slab-OrrGrade perim = 55.0 X R-13 Wall 511.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (") denote conduction through an interior surface to Infiltration: 1.00 X 1.064 X 850 X Schedule Air Sensible Area Ceiling Fraction U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 46 = 1,017 46 = Z693 46 = 9,969 46 = 1,847 0= 0 = = = = = = = = = = = = = = = = = = = = = = = = = Page Total 15,526 / 60 ] X 46 = 1,661 AT 0.0260 0.0690 0.4800 0.7300 0.1020 another room 9.00 X 0.266 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 17,187 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 38 of 48 ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 3 Floor Area 850.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 850.0 R-21 WaH (W.21.2x6.16) 1,313.0 opp LowE METAL .48/.19 447.0 Slab -On -Grade perim = 63.0 *R-13 Wall 485.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 850 X Schedule Air Sensible Area Fraction U-Value X 0.0260 X 0.0690 X 0.4800 X 0.7300 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.00 X 0.266 Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr 46 = 1,017 46 = 4,167 46 = 9,870 46 = = 2,787 0 0 = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total / 60 ] X 46 AT 17,841 = 1,661 TOTAL HOURLY HEAT LOSS FOR ROOM 19,502 EnergyPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-08-05T20.29.00 ID: Page 39 of 48 J I ROOM HEATING PEAK LOADS Project Name Ratpack Residence Date 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Floor Area 850.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 850.0 X 0.0260 1,416.0 X 0.0690 274.0 X 0.4800 30.0 X 0.3400 perim = 83.0 X 0.7300 511.0 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 850 X 9.00 X 0.266 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F Btu/hr 46 = 1,017 46 = 4,494 46 = 6,050 46 = 469 46 = 2, 787 0 = 0 = = = = = = = = = = = = = = = = = = = = = = = = = Page Total 14,817 / 60 ] X 46 = 1,661 AT R-38 Roof Attic R-21 Wall (W.21.2x6.16) opp LowE METAL .48/.19 fx LowE METAL .34/.25 Slab -On -Grade *R-13 Wall Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,479 Ene►gyPm 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29.00 Q Page 40 of 48 1 1 1 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 862.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic (1M 862.0 X 0.0260 X 56.0 = 1,255 R-21 Wall (W.21.2x6.16) (E) 150.0 X 0.0690 X 32.1 = 332 R-21 Wall (W 21.2x6.16) (S) 593.2 X 0.0690 X 27.1 = 1,110 R-21 Wall (W 21.2x6.16) (169 305.0 X 0.0690 X 32.6 = 685 R-21 Wall (W.21.2x6.16) (N) 793.8 X 0.0690 X 29.0 = 1,588 *R-13 Wall 452.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 4,971 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr D3 (S) 31.8 X 16.1 + 0.0 X 17.4 = 511 D2 (S) 0.0 X 16.1 + 41.0 X 17.4 = 713 22 (S) 0.0 X 16.7 + 54.0 X 17.7 = 953 21 (1M 0.0 X 16.7 + 135.0 X 27.5 = 3,714 D1 (N) 0.0 X 16.1 + 30.2 X 24.1 = 728 20 (N) 0.0 X 16.7 + 64.0 X 22.8 = 1,457 C2 (N) 0.0 X 16.1 + 12.0 X 24.1 = 269 X + X = F=� X + X = Page Total 8,36 Internal Gain Btu/hr Occupants 2 6 Occupants X 245 Btuh/occ. = 634 Equipment 862 Floor Area X 0.50 w/sgft = 1,471 Infiltration: 1.064 X 0.94 X 35.55 X 42 = 1,486 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,928 Latent Gain Btulhr Occupants 2 6 Occupants X 155 Btuh/occ. = 401 Infiltration: 4,771 X 0.94 X 35.55 X 0.00523 = 830 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 401 Ene Pro 6.7 by EnerpySoft User Number. 6712 RunCode: 2p15-08-05T20:29:00 ID: Page 41 of 48 1 1 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1 8/5,2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,882.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W..21.2x6.16) *R-13 Wall Orientation Area X X X X X X X X X U-Factor X X X X X X X X X CLTD' = = = = = = = = = 1,882.0 0.0260 W.0 433.7 0.0690 32.1 241.1 0.0690 27.1 641.7 0.0690 32.6 335.3 0.0690 29.0 721.0 0.1020 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Fenestration 58 G4 G3 G2 23 E2 24 G1 E1 Orientation Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area 131.E 16.7 83.4 0.0 16.1 51.3 0.0 16.1 1&0 0.0 16.1 18.8 77.0 16.7 0.0 95.1 16.1 0.0 203.8 16.1 32.7 0.0 16.1 52.0 122.3 16.1 72.5 5.6 Occupants X 245 Btuh/occ. 1,882 Floor Area X 0.50 W/so Btu/hr 2,740 961 451 1,441 1 6711 X X X X X X XEl X X GLF = = = - = = - = - Btu/hr 26.8 4,425 29.4 1,509 17.4 313 17.4 327 1,282 1,529 4,246 1,579 4,168 Page Total 19,37 Btu/hr = 3„ Infiltration: X X 77.62 X F 3,245 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,337 Latent Gain Btu/hr Occupants 5.6 Occupants X 155 Btuh/occ. = 875 Infiltration: 4,771 X 0.94 X 77.62 X 0.00523 = Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM d751 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,882.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btufhr G6 (N) 0.0 X 16.1 + 27.4 X 24.1 = 661 G5 (N) 0.0 X 16.1 + 63.3 X 24.1 = 1,527 D51 (N) 0.0 X 18.1 + 24.0 X 27.8 = 667 X + X = X + X = X + X — X + X = X + X = X + X = Page Total Z854 Internal Gain Btu/hr Occupants 5 6 Occupants X 245 Btuh/occ. = 1,363 Equipment 1,882 Floor Area X 0.50 w/sgft = 3,212 Infiltration: 1.064 X 0.94 X 77.62 X 42 = 3,245 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,337 Latent Gain Btu/hr Occupants 5 6 Occupants X 155 Btuh/occ. = 875 Infiltration: 4,771 X 0.94 X 77.62 X 0.00523 = 1,813 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 875 Ene Pro 6.7 by EnerqySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 1D. Page 43 of 48 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Family Entry Hidden Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 1,462.0 tt2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr R-38 Roof Attic AM 1,462.0 X 0.0260 X 56.0 = 2,129 R-21 Wall (W.21.2x6.16) (E) 825.0 X 0.0690 X 32.1 = 1,828 R-21 Wall (W.21.2x6.16) (S) 892.0 X 0.0690 X 27.1 = 1,669 R-21 Wall (W.21.2x6.16) (lN) 150.0 X 0.0690 X 32.6 = 337 R-21 Wall (W.21.2x6.16) (N) 1,588.5 X 0.0690 X 29.0 = 3,179 *R-13 Wall 822.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 9,141 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 01 (E) 0.0 X 37.0 + 55.0 X 63.1 = 3,471 D6 (E) 0.0 X 16.7 + 20.0 X 26.8 = 536 04 (S) 0.0 X 16.7 + 176.0 X 17.7 = 3,143 A (S) 0.0 X 37.0 + 55.0 X 39.6 = Z 177 C1 (N) 0.0 X 16.1 + 16.5 X 24.1 = 398 13 (N) 0.0 X 16.7 + 24.0 X 22.8 = 546 8 (N) 0.0 X 16.1 + 177.0 X 24.1 = 4,269 X + X = X + X = Page Total 14,53 Internal Gain Btu/hr Occupants 44 Occupants X 245 Btuh/occ. = 1,075 Equipment 1,462 Floor Area X 0.50 W/sq{ = 2,495 Infiltration: 1.064 X 0.94 X 60.30 X 42 = 2,521 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,770 Latent Gain Btu/hr Occupants 4 4 Occupants X 155 Btuh/occ. = 680 Infiltration: 4,771 X 0.94 X 60.30 X 0.00523 = 1,408 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 680 Enem YPro 6.7 by EnerqySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 44 of 48 1 J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Rooms Outdoor Dry Bulb Temperature 112 OF Floor Area 900.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roof Attic AM 900.0 X 0.0260 X 56.0 = 1,310 R-21 Wall (W.21.2x6.16) (E) 525.0 X 0.0690 X 32.1 = 1,163 R-21 Wall (W.21.2x6.16) (S) 505.0 X 0.0690 X 27.1 = 945 R-21 Wall (W.21.2x6.16) (tM 437.0 X 0.0690 X 32.6 = 962 R-21 Wall (W.21.2x6.16) (N) 633.0 X 0.0690 X 29.0 = 1,267 'R-13 Wall 656.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 5,667 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 50 (S) 80.0 X 16.7 + 0.0 X 17.7 = 1,332 46 (S) 150.0 X 16.7 + 0.0 X 17.7 = 2, 498 45 I'M 0.0 X 16.7 + 88.0 X 27.5 = 2,421 44 (N) 0.0 X 16.7 + 43.0 X 22.8 = 979 43 (N) 0.0 X 16.7 + 35.0 X 22.8 = 797 51 (N) 0.0 X 16.1 + 24.0 X 24.1 = 579 X + X = X + X = X + X = Page Total 8,60 Internal Gain Btu/hr Occupants 2.7 Occupants X 245 Btuh/occ. = 661 Equipment 900 Floor Area X 0•50 W/sgft Infiltration: 1.064 X 0.94 X 37.12 X 42 = 1,552 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,020 Latent Gain Btu/hr Occupants 2 7 Occupants X 155 Btuh/occ. = 418 Infiltration: 4,771 X 0.94 X 37.12 X 0.00523 = 867 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 418 EnefpyPro 6.7 by EnerpySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 ID: Page 45 of 48 J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Lounge room Outdoor Dry Bulb Temperature 112 OF Floor Area 850.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btufhr R-38 Roof Attic 850.0 X 0.0260 X 56.0 = 1,238 R-21 Wall (W.21.2x6.16) (E) 435.0 X 0.0690 X 32.1 = 964 R-21 Wall (W.21.2x6.16) (VlQ 413.5 X 0.0690 X 32.6 = 929 'R-13 Wall 511.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = X X = Page Total 3,130 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btufhr 56 (E) 131.E X 16.7 + 83.4 X 26.8 = 4,425 24 203.8 X 16.7 + 32.7 X 27.5 = 4,293 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 8,71 Internal Gain Btu/hr Occupants 2.5 Occupants X 245 Btuh/occ. = 625 Equipment 850 Floor Area X 0•50 w/sgft = 1,451 Infiltration: 1.064 X 0.94 X 35.06 X 42 = 1,465 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,389 Latent Gain Btu/hr Occupants 2 5 Occupants X 155 Btuh/occ. = 395 Infiltration: 4, 771 X 0.94 X 35.06 X 0.00523 = 819 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 395 Ene Pro 6.7 by EnerpySoft User Number. 6712 RunCode: 2015-08-05T20:29.00 ID: Page 46 of 48 1 1 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1 81512015 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 850.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btulhr R-38 Roof Attic (tM 850.0 X 0.0260 X 56.0 = 1,238 R-21 Wall (W.21.2x6.16) (E) 472.0 X 0.0690 X 32.1 = 1,046 R-21 Wall (W.21.2x6.16) (S) 472.0 X 0.0690 X 27.1 = 883 R-21 Wall (W.21.2x6.16) (N) 369.0 X 0.0690 X 29.0 = 738 *R-13 Wall 485.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 3,905 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btulhr 37 (E) 53.9 X 16.7 + 34.1 X 26.8 = 1,811 38 (S) 150.0 X 16.7 + 0.0 X 17.7 = Z498 42 (S) 78.0 X 16.7 + 0.0 X 17.7 = 1,299 35 (N) 0.0 X 16.7 + 78.0 X 22.8 = 1,775 36 (N) 0.0 X 16.7 + 53.0 X 22.8 = 1,206 X + X = X + X = X + X = X + X = Page Total 8,58 Internal Gain Btulhr Occupants 2.5 Occupants X 245 Btuh/occ. =LA Equipment 850 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 0.94 X 35.06 X 42 = 1,465 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,034 Latent Gain Btu/hr Occupants77�1 2 5 Occupants X 155 Btuh/occ. = 395 Infiltration: 4,771 X 0.94 X 35.06 X 0.00523 = 819 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 395 Ene Pro 6.7 by EnetpySolt User Number. 6712 RunCode: 2015-08-05T20.29.00 ID: Page 47 of 48 1 J I F I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Ratpack Residence 1 8/5/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 850.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 RoofAttfc (IAq 850.0 X 0.0260 X 56.0 = 1,238 R-21 Wall (W..21.2x6.16) (S) 612.0 X 0.0690 X 27.1 = 1,145 R-21 Wall (W.21.2x6.16) (IAA 392.0 X 0.0690 X 32.6 = 881 R-21 Wall (W.21.2x6.16) (N) 412.0 X 0.0690 X 29.0 = 824 •R-13 Wall 511.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 4,087 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Stu/hr 32 (S) 0.0 X 16.7 + 78.0 X 17.7 = 1,377 F (S) 0.0 X 16.1 + 30.0 X 17.4 = 522 28 (149 102.4 X 16.7 + 5.6 X 27.5 = 1,860 27 (N) 0.0 X 16.7 + 53.0 X 22.8 = 1,206 26 (N) 0.0 X 16.7 + 35.0 X 22.8 = 797 X + X = X + X = X + X = X + X Page Total 5,76 Internal Gain Stuthr Occupants 2 5 Occupants X 245 Btuh/occ. = 625 Equipment 850 Floor Area X 0.50 w/sgft = 1,451 Infiltration: 1.064 X 0.94 X 35.06 X 42 = 1,465 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,390 Latent Gain Btuihr Occupants 2 5 Occupants X 155 Btuh/occ. = 395 Infiltration: 4,771 X 0.94 X 35.06 X 0.00523 = 819 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 395 Ene 6.7 bv EnemySoft User Number. 6712 RunCode: 2015-08-05T70:29:00 1D: Pagg 48 of 48