BRES2015-0302 Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Ratpack Residence
53-525 Humbolt Blvd.
La Quinta, CA 92253
Project Designer:
Gordon Stein
55-053 Sorrel Court
Indio, CA 92201
(760) 773-4488
Report Prepared by:
Tim Scott
Scott Design and Tit 24, Inc,
77085 Michia
Palm Desert, C"^�
(760) 200-47� No SgFE�/nl 7',4
T�
'i �ON
°b "°'"bey: RECEIVED
Date:
AUG 06 2015
8/5/2015 CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the Cafrfomia Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7 by EnergySoff User Number. 6712 ID:
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 18
Form MF-1 R Mandatory Measures Summary 20
HVAC System Heating and Cooling Loads Summary 24
Room Load Summary 29
Room Heating Peak Loads 34
Room Cooling Peak Loads 41
I EnergyPro 6.7 by EnergySoft Job Number ID: User Number 6712
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1R-PRF-01
Page 1 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
GENERAL INFORMATION
01
Project Name
Ratpack
02
Calculation Description
Title 24 Analysis
03
Project Location
53-525 Humbolt Blvd.
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
80
12
Project Scope
Newly Co str to
3
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
7656
Number of Zones
7
16
Slab Area (ft2)
7656 & SAFETY
DEM.
Number of Stories
1
18
Addition Cond. Floor Area
N/A
Natural Gas Available
Yes
r2O
Addition Slab Area (ft2)
N/A CT
(>�
Glazing Percentage (%)
46.9%
COMPLIANCE RESULTS BYAL
01 Building Complies with Computer Performance
02
This building incorporates features that require field testing and/Pr'verification by a certifiedHERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
05
06
07
08
Energy Usk (k?dV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating;, .
5.26
9.10
-3.84
-73.0%
S ce Coolly ' ,
121.26
113.17
8.09
6.7%
,.
IA ntilation
0.71
0.71
0.00
0.0%
Wate ting
3.35
3.74
-0.39
-11.6%
Qhotoyoltai set
----
0.00
0.00
----
Compliancq_,F ergy Total
130.58
126.72
3.86
3.0%
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015 Page 2 of 15
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (0I1)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely in conditioned space
Domestic Hot Water System Verifications: -
• -None -Al
-
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)'
164.95
161.09
3.86
2.3%
' includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Ratpack
7656
1
5
7
5
1
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Page 3 of 15
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
master
Conditioned
HVAC 1 mstr1
862
9
DHW Sys 1
great room
Conditioned
HVAC 2 grt2
1882
9
DHW Sys 1
family
Conditioned
HVAC 3 fam3
1462
9
DHW Sys 1
guest-4
Conditioned
HVAC 44
900
9
DHW Sys 1
lounge
Conditioned
HVAC 44
850
9
DHW Sys 1
3
Conditioned
HVAC 55
850
9
1 DHW Sys 1
2
Conditioned
HVAC 55
1850
1 9
1 DHW Sys 1
ca- 10E:RT:c'>,., 1"nC.,
P-# F F2 S- P R Q V I D E R
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
Page 4 of 15
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
80d Wall
master
R-21 Wall (W.21.2x6.16)
80
Front
150
90
170d Wall
master
R-21 Wall (W.21.2x6.16)
170
Left
720
126.8
90
260d Wall
master
R-21 Wall (W.21.2x6.16)
260
Back
440
135
90
350d Wall
master
R-21 Wall (W.21.2x6.16)
350
Right
900
106.2
90
Roof R-38
master
R-38 Roof Attic
862
80d Wall 2
great room
R-21 Wall (W.21.2x6.16)
80
Front
700
266.3
90
170d Wall 2
great room
R-21 Wall (W.21.2x6.16)
170
Left
450
208.93
90
260d Wail 2
great room
R-21 Wall (W.21.2x6.16)
260
Back
1125
483.29
90
350d Wall 2
great room
R-21 Wall (W.21.2x6.16)
350
Right
450
114.7
90
Roof R-38 2
great room
R-38 Roof Attic
1882
80d Wall 3
family
R-21 Wall (W.21.2x6.16)
80
Front
900
75
90
170d Wall 3
family
R-21 Wall (W.21.2x6.16)
170
Left
1125
233
90
260d Wall 3
family
R-21 Wall (W.21.2x6.16)
260
Back
150
90
350d Wall 3
family
R-21 Wall (W.21.2x6.16)
350
Right
1806
217.5
90
Roof R-38 3
family
R-38 Roof Attic
1462
80d Wall 4
guest-4
R-21 Wall (W.21.2x6.18)
80
Front
525
90
170d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
170
Left
735
230
90
260d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
260
Back
525
88
90
350d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
350
Right
735
102
90
Roof R-38 4
guest-4
R-38 Roof Attic
900
80d Wall 5
lounge
R-21 Wall (W.21.2x6.16)
80
Front
650
215
90
260d Wall 5
lounge
R-21 Wall (W.21.2x6.16)
260
Back
650
236.5
90
Roof R-38 5
lounge
R-38 Roof Attic
850
80d Wall 6
3
R-21 Wall (W.21.2x6.16)
80
Front
560
88
90
170d Wall 5
3
R-21 Wall (W.21.2x6.16)
170
Left
700
227.973
90
350d Wail 5
3
R-21 Wall (W.21.2x6.16)
350
Right
500
131
90
Roof R-38 6
3
R-38 Roof Attic
850
170d Wall 6
2
R-21 Wall (W.21.2x6.16)
170
Left
720
108
90
260d Wall 6
2
R-21 Wall (W.21.2x6.16)
260
Back
500
108
90
350d Wall 6
2
R-21 Wall (W.21.2x6.16)
350
Right
500
87.992
90
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml
Roof R-38 7 2 R-38 Roof Attic 850
CFI R-PRF-01
Page 5 of 15
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic master
Attic Roofmaster
Ventilated
3
0.62
0.83
No
Yes
Attic great room
Attic Roofgreat room
Ventilated
3
0.62
0.83
No
Yes
Attic family
Attic Rooffamily
Ventilated
3
0.62
0.83
No
Yes
Attic guest-4
Attic Roofguest-4
Ventilated
3
0.62
0.83
No
Yes
Attic lounge
Attic Rooflounge
Ventilated
3
0.62
0.83
No
Yes
Attic 3
Attic Roof3
Ventilated
3
0.62
0.83
No
Yes
Attic 2
Attic Roof2
Ventilated
3
0.62
0.83
No
Yes
� Fi F-� 11-4, S.
- ...alCERTS
P R C-) V I E R
Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaiCERTS inc,
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xm1
CFIR-PRF-01
Page 6 of 15
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(W)
U-factor
SHGC
Exterior Shading
D3
Window
170d Wall (Left-170)
10.6
3.0
1
31.8
0.34
0.25
Insect Screen (default)
D2
Window
170d Wall (Left-170)
----
----
1
41.0
0.34
0.25
Insect Screen (default)
22
Window
170d Wail (Left-170)
----
----
1
54.0
0.48
0.19
Insect Screen (default)
21
Window
260d Wall (Back-260)
---
----
1
135.0
0.48
0.19
Insect Screen (default)
D1
Window
350d Wall (Right-350)
- -
----
1
30.2
0.34
0.25
Insect Screen (default)
20
Window
350d Wall (Right-350)
- -
-__
1
64.0
0.48
0.19
Insect Screen (default)
C2
Window
350d Wall (Right-350)
----
1
12.0
0.34
0.25
Insect Screen (default)
58
Window
80d Wall 2 (Front-80)
21.5
10.0
1
215.0
0.48
0.19
Insect Screen (default)
G4
Window
80d Wall 2 (Front-80)
----
----
1
51.3
0.34
0.25
Insect Screen (default)
G3
Window
170d Wall 2 (Left-170)
----
----
1
18.0
0.34
0.25
Insect Screen (default)
G2
Window
170d Wall 2 (Left-170)
----
----
1
18.8
0.34
0.25
Insect Screen (default)
23
Window
170d Wall 2 (Left-170)
7.0
11.0
1
77.0
0.48
0.19
Insect Screen (default)
E2
Window
170d Wall 2 (Left-170)
6.3
15.1
1
95.1
0.34
0.25
Insect Screen (default)
24
Window
260d Wall 2 (Back-260)
21.5
11.0
1
236.5
0.38
0.23
Insect Screen (default)
G1
Window
260d Wall 2 (Back-260)
----
---
1
52.0
0.34
0.25
Insect Screen (default)
E1
Window
260d Wall 2 (Back-260)
12.9
15.1
1
194.8
0.34
0.25
Insect Screen (default)
G6
Window
350d Wall 2 (Right-350)
----
----
1
27.4
0.34
0.25
Insect Screen (default)
G5
Window
350d Wall 2 (Right-350)
----
--
1
63.3
0.34
0.25
Insect Screen (default)
D51
Window
350d Wall 2 (Right-350)
---
1
24.0
0.35
0.30
Insect Screen (default)
01
Window
80d Wall 3 (Front-80)
1
55.0
0.94
0.49
Insect Screen (default)
D6
Window
80d Wall 3 (Front-80)
----
----
1
20.0
0.48
0.19
Insect Screen (default)
04
Window
170d Wall 3 (Left-170)
----
--
1
178.0
0.48
0.19
Insect Screen (default)
A
Window
170d Wall 3 (Left-170)
----
----
1
55.0
0.94
0.49
Insect Screen (default)
C1
Window
350d Wall 3 (Right-350)
---
1
16,5
0.34
0.25
Insect Screen (default)
13
Window
350d Wall 3 (Right-350)
---
1
24.0
0.48
0.19
Insect Screen (default)
B
Window
350d Wall 3 (Right-350)
----
----
1
177.0
0.34
0.25
Insect Screen (default)
50
Window
170d Wall 4 (Left-170)
8.0
10.0
1
80.0
0.48
0.19
Insect Screen (default)
46
Window
170d Wall 4 (Left-170)
15.0
10.0
1
150.0
0.48
0.19
Insect Screen (default)
45
Window
260d Wall 4 (Back-260)
----
----
1
88.0
0.48
0.19
Insect Screen (default)
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xm1
CF1R-PRF-01
Page 7 of 15
44
Window
350d Wall 4 (Right-350)
--•
1
43.0
0.48
0.19
Insect Screen (default)
43
Window
350d Wall 4 (Right-350)
----
----
1
35.0
0.48
0.19
Insect Screen (default)
51
Window
350d Wall 4 (Right-350)
----
----
1
24.0
0.34
0.25
Insect Screen (default)
582
Window
80d Wall 5 (Front-80)
21.5
10.0
1
215.0
0.48
0.19
Insect Screen (default)
242
Window
260d Wall 5 (Back-260)
21.5
11.0
1
236.5
0.48
0.19
Insect Screen (default)
37
Window
80d Wall 6 (Front-80)
8.8
10.0
1
88.0
0.48
0.19
Insect Screen (default)
38
Window
170d Wall 5 (Left-170)
15.0
10.0
1
150.0
0.48
0.19
Insect Screen (default)
42
Window
170d Wall 5 (Left-170)
7.9
10.0
0.987
78.0
0.48
0.19
Insect Screen (default)
35
Window
350d Wall 5 (Right-350)
----
----
1
78.0
0.48
0.19
Insect Screen (default)
36
Window
350d Wall 5 (Right-350)
--
1
53.0
0.48
0.19
Insect Screen (default)
32
Window
170d Wall 6 (Left-170)
----
----
1
78.0
0.48
0.19
Insect Screen (default)
F
Window
170d Wall 6 (Left-170)
----
----
1
30.0
0.34
0.25
Insect Screen (default)
28
Window
260d Wall 6 (Back-260)
10.8
10.0
1
108.0
0.48
0.19
Insect Screen (default)
27
Window
350d Wall 6 (Right-350)
5.3
10.0
1
53.0
0.48
0.19
Insect Screen (default)
26
Window
350d Wall 6 (Right-350)
10.8
10.0
0.324
35.0
0.48
0.19
Insect Screen (default)
('AICERTS,
t.-I S R 0, V
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CFI R-PRF-01
Page 8 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
D3
10
0A
10
10
0
0
0
0
0
0
0
0
0
58
10
0.1
10
10
0
0
0
0
0
0
0
0
0
23
18
0.1
18
18
0
0
0
0
0
0
0
0
0
E2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
24
10
0.1
10
10
0
0
0
0
0
0
0
0
0
E1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
50
10
0.1
10
10
0
0
0
0
0
0
0
0
0
46
10
0.1
10
10
0
0
0
0
0
0
0
0
0
582
10
0.1
10
10
0
0
0
0
0
0
0
0
0
242
10
0.1
10
10
0
0
0
0
0
0
0
0
0
37
10
0.1
10
10
0
0
0
0
0
0
0
0
0
38
10
0.1
10
10
0
0
0
0
0
0
0
0
0
42
10
0.1
10
10
0
0
0
0
0
0
0
0
0
28
10
0.1
10
10
0
0
0
0
0
0
0
0
0
27
8
0.1
8
8
0
0
0
0
0
0
0
0
0
26
6
0.1
6
6
0
0
0
0
0
0
0
0
0
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CFI R-PRF-01
Page 9 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofmaster
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgreat room
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0,644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooffamily
Attic Roofs
Wood Framed Ceiling
in. O.G.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic Roofguest-4
Attic Roofs
Wood Framed Ceiling
in. O.0
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooflounge
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof3
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-0517:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1 R-PRF-01
Page 10 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
master
862
100
None
0.8
No
Covered Slab 2
great room
1882
88
None
0.8
No
Covered Slab 3
family
1462
166
None
0.8
No
Covered Slab 4
guest-4
900
121
None
0.8
No
Covered Slab 5
lounge
850
55
None
0.8
No
Covered Slab 6
3
850
83
None
0.8
No
Covered Slab 7
2
850
83
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (011)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 112
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/2
---
---
---
---
--
--
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Pagel 1 of 15
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 mstrl
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC 2 grt2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC 3 fam3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC 44
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC 55
Other Heating and Cooling
System
Heating Component 5
Cooling Component 5
HVAC Fan 5
Air Distribution System 5
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace 9
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 5
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 215-NO2022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1 R-PRF-01
Page 12 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13.1
16.7
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 3
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 4
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 5
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
150
Required
Required
Required
Cooling Component 3-hers-cool
Required
150
Required
Required
Required
Cooling Component 4-hers-cool
Required
150
Required
Required
Required
Cooling Component 5-hers-cool
Required
150
Required
Required
Required
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack- Stein- 15.xmi
CF1 R-PRF-01
Page 13 of 15
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
Air Distribution System 2
LowLICod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
2-hers-dist
Air Distribution System 3
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
3-hers-list
Air Distribution System 4
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
4-hers-dist
Air Distribution System 5
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
5-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 2-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
Air Distribution System 3-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 4-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 5-hers-list
Required
6.0
Required
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.58
HVAC Fan 5-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Registration Number: 215-NO2022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CFI R-PRF-01
Page 14 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0,58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
HVAC Fan 5-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
121.56
0.25
Default
0
Required
COOLING VENTILATION
01
02
03
04
05
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Total Watts
Number of Fans
WH Fan 1
61;•
: c 4,"`<
32
1
WH Fan 2
61
'• 4'.' 0. 459
32
1
WH Fan 3
61
= 0.6245'r"N
k'132
1
WH Fan 4
61
0. 9 V 1
32
1
WH Fan 5
61
0.52459
32
1
PROJECT NOTES
The Madison Club
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Page 15 of 15
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Z;r1'-5C'Vz i'
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-08-05 17:14:55
Address:
CEA/HERS Certification Identification (if applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature'.
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2015-08-05 17:14:55
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by Ca10ERT5. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
Page 1 of 15
GENERAL INFORMATION
01
Project Name
Ratpack
02
Calculation Description
Title 24 Analysis
03
Project Location
53-525 Humbolt Blvd.
04
City
La Quinta
05
Standards Version
Compliance 2015
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2013-4 (744)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.6
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
80
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
7656
15
Number of Zones
7
16
Slab Area (ft2)
7656
17
Number of Stories
1
18
Addition Cond. Floor Area
NIA
19
Natural Gas Available
Yes
20
Addition Slab Area (ft)
N/A
21
Glazing Percentage (%)
46.9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft -yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
5.26
9.10
-3.84
-73.0%
Space Cooling
121.26
113.17
8.09
6.7%
IAQ Ventilation
0.71
0.71
0.00
0.0%
Water Heating
3.35
3.74
-0.39
-11.6%
Photovoltaic Offset
----
0.00
0.00
---
Compliance Energy Total
130.58
126.72
3.86
3.0%
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cool roof
• Window overhangs and/or fins
CF1 R-PRF-01
Page 2 of 15
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High Quality Insulation Installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirety In conditioned space
Domestic Hot Water System Verifications:
--None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on -site renewable energy system.
Reference Energy Use
Energy Design Rating
Margin
Percent Improvement
Total Energy (kTDV/f2-yr)'
164.95
161.09
3.86
2.3%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Ratpack
7656
1
5
7
5
1
Registration Number: 215-No202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Page 3 of 15
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
master
Conditioned
HVAC 1 mstrl
862
9
DHW Sys 1
great room
Conditioned
HVAC 2 grt2
1882
9
DHW Sys 1
family
Conditioned
HVAC 3 fam3
1462
9
DHW Sys 1
guest-4
Conditioned
HVAC 44
900
9
DHW Sys 1
lounge
Conditioned
HVAC 44
850
9
DHW Sys 1
3
Conditioned
HVAC 55
850
9
DHW Sys 1
2
Conditioned
HVAC 55
850
9
DHW Sys 1
C.
CaICERTS In.
Registration Number: 215-N02022858-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Page 4 of 15
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
80d Wall
master
R-21 Wall (W.21.2x6.16)
80
Front
150
90
170d Wall
master
R-21 Wall (W.21.2x6.16)
170
Left
720
126.8
90
260d Wall
master
R-21 Wall (W.21.2x6.16)
260
Back
440
135
90
350d Wall
master
R-21 Wall (W.21.2x6.16)
350
Right
900
106.2
90
Roof R-38
master
R-38 Roof Attic
862
80d Wall 2
great room
R-21 Wall (W.21.2x6.16)
80
Front
700
266.3
90
170d Wall 2
great room
R-21 Wall (W.21.2x6.16)
170
Left
450
208.93
90
260d Wall 2
great room
R-21 Wall (W.21.2x6.16)
260
Back
1125
483.29
90
350d Wall 2
great room
R-21 Wall (W.21.2x6.16)
350
Right
450
114.7
90
Roof R-38 2
great room
R-38 Roof Attic
1882
80d Wall 3
family
R-21 Wall (W.21.2x6.16)
80
Front
900
75
90
170d Wall 3
family
R-21 Wall (W.21.2x6.16)
170
Left
1125
233
90
260d Wall 3
family
R-21 Wall (W.21.2x6.16)
2Ei0
Back
150
90
350d Wall 3
family
R-21:Wall (W.21.2x6.16)
350
Right
1806
217.5
90
Roof R-38 3
family
R-3KRobf Attic
1462
80d Wall 4
guest-4
R'-21 Wall (W.21.2x6.16)
80
Front
525
90
170d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
170
Left
735
230
90
260d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
260
Back
525
88
90
350d Wall 4
guest-4
R-21 Wall (W.21.2x6.16)
350
Right
735
102
90
Roof R-38 4
guest-4
R-38 Roof Attic
900
80d Wall 5
lounge
R-21 Wail (W.21.2x6.16)
80
Front
650
215
90
260d Wall 5
lounge
R-21 Wall (W.21.2x6.16)
260
Back
650
236.5
90
Roof R-38 5
lounge
R-38 Roof Attic
850
80d Wall 6
3
R-21 Wall (W.21.2x6.16)
80
Front
560
88
90
170d Wall 5
3
R-21 Wall (W.21.2x6.16)
170
Left
700
227.973
90
350d Wall 5
3
R-21 Wall (W.21.2x6.16)
350
Right
500
131
90
Roof R-38 6
3
R-38 Roof Attic
850
170d Wall 6
2
R-21 Wall (W.21.2x6.16)
170
Left
720
108
90
260d Wall 6
2
R-21 Wall (W.21.2x6.16)
260
Back
500
108
90
350d Wall 6
2
R-21 Wall (W.21.2x6.16)
350
Right
500
87.992
90
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015.08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi
Roof R-38 7 2 R-38 Roof Attic 850
CF1 R-PRF-01
Page 5 of 15
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic master
Attic Roofmaster
Ventilated
3
0.62
0.83
No
Yes
Attic great room
Attic Roofgreat room
Ventilated
3
0.62
0.83
No
Yes
Attic family
Attic Rooffamily
Ventilated
3
0.62
0.83
No
Yes
Attic guest-4
Attic Roofguest-4
Ventilated
3
0.62
0.83
No
Yes
Attic lounge
Attic Rooflounge
Ventilated
3
0.62
0.83
No
Yes
Attic 3
Attic Roof3
Ventilated
3
0.62
0.83
No
Yes
Attic 2
Attic Roof2
Ventilated
3
0.62
0.83
No
Yes
�iCaICERI
I mo:'� "-.
Registration Number: 215-N02022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-0517:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1 R-PRF-01
Page 6 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ft)
U factor
SHGC
Exterior Shading
D3
Window
170d Wall (Left-170)
16.6
3.0
1
31.8
0.34
0.25
Insect Screen (default)
D2
Window
170d Wall (Left-170)
---
----
1
41.0
0.34
0.25
Insect Screen (default)
22
Window
170d Wall (Left-170)
----
--
1
54.0
0.48
0.19
Insect Screen (default)
21
Window
260d Wall (Back-260)
--
--
1
135.0
0.48
0.19
Insect Screen (default)
D1
Window
350d Wall (Right-350)
---
----
1
30.2
0.34
0.25
Insect Screen (default)
20
Window
350d Wall (Right-350)
--
---
1
64.0
0.48
0.19
Insect Screen (default)
C2
Window
350d Wall (Right-350)
---
---
1
12.0
0.34
0.25
Insect Screen (default)
58
Window
80d Wall 2 (Front-80)
21.5
10.0
1
215.0
0.48
0.19
Insect Screen (default)
G4
Window
80d Wall 2 (Front-80)
----
----
1
51.3
0.34
0.25
Insect Screen (default)
G3
Window
170d Wall 2 (Left-170)
----
----
1
18.0
0.34
0.25
Insect Screen (default)
G2
Window
170d Wall 2 (Left-170)
----
----
1
18.8
0.34
0.25
Insect Screen (default)
23
Window
170d Wall 2 (Left-170)
7.0
11.0
1
77.0
0.48
0.19
Insect Screen (default)
E2
Window
170d Wall 2 (Left-170)
6.3
15.1
1
95.1
0.34
0.25
Insect Screen (default)
24
Window
260d Wall 2 (Back-260)
21.5
11.0
1
236.5
0.38
0.23
Insect Screen (default)
G1
Window
260d Wall 2 (Back-260)
-
1
52.0
0.34
0.25
Insect Screen (default)
E1
Window
260d Wall 2 (Back-260)
12.9
15.1
1
194.8
0.34
0.25
Insect Screen (default)
G6
Window
350d Wall 2 (Right-350)
----
---
1
27.4
0.34
0.25
Insect Screen (default)
G5
Window
350d Wall 2 (Right-350)
---
---
1
63.3
0.34
0.25
Insect Screen (default)
D51
Window
350d Wall 2 (Right-350)
-
-
1
24,0
0.35
0.30
Insect Screen (default)
01
Window
80d Wall 3 (Front-80)
----
----
1
55.0
0.94
0.49
Insect Screen (default)
D6
Window
80d Wall 3 (Front-80)
----
----
1
20.0
0.48
0.19
Insect Screen (default)
04
Window
170d Wall 3 (Left-170)
----
----
1
178.0
0.48
0.19
Insect Screen (default)
A
Window
170d Wall 3 (Left-170)
----
----
1
55.0
0.94
0.49
Insect Screen (default)
C1
Window
350d Wall 3 (Right-350)
----
----
1
16.5
0.34
0.25
Insect Screen (default)
13
Window
350d Wall 3 (Right-350)
---
1
24.0
0.48
0.19
Insect Screen (default)
B
Window
350d Wall 3 (Right-350)
----
----
1
177.0
0.34
0.25
Insect Screen (default)
50
Window
170d Wall 4 (Left-170)
8.0
10.0
1
80.0
0.48
0.19
Insect Screen (default)
46
Window
170d Wall 4 (Left-170)
15.0
10.0
1
150.0
0.48
0.19
Insect Screen (default)
45
Window
260d Wall 4 (Back-260)
----
----
1
88.0
0.48
0.19
Insect Screen (default)
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack-Stein-15.xmi
C F 1 R-PRF-01
Page 7 of 15
44
Window
350d Wall 4 (Right-350)
---
-
1
43.0
0.48
0.19
Insect Screen (default)
43
Window
350d Wall 4 (Right-350)
- -
--
1
35.0
0.48
0.19
Insect Screen (default)
51
Window
350d Wall 4 (Right-350)
----
----
1
24.0
0.34
0.25
Insect Screen (default)
582
Window
80d Wall 5 (Front-80)
21.5
10.0
1
215.0
0.48
0.19
Insect Screen (default)
242
Window
260d Wall 5 (Back-260)
21.5
11.0
1
236.5
0.48
0.19
Insect Screen (default)
37
Window
80d Wall 6 (Front-80)
8.8
10.0
1
88.0
0.48
0.19
Insect Screen (default)
38
Window
170d Wall 5 (Left-170)
15.0
10.0
1
150.0
0.48
0.19
Insect Screen (default)
42
Window
170d Wall 5 (Left-170)
7.9
10.0
0.987
78.0
0.48
0.19
Insect Screen (default)
35
Window
350d Wall 5 (Right-350)
----
----
1
78.0
0.48
0.19
1 Insect Screen (default)
36
Window
350d Wall 5 (Right-350)
----
----
1
53.0
0.48
0.19
Insect Screen (default)
32
Window
170d Wall 6 (Left-170)
----
----
1
78.0
0.48
0.19
Insect Screen (default)
F
Window
170d Wall 6 (Left-170)
---
----
1
30.0
0.34
0.25
Insect Screen (default)
28
Window
260d Wall 6 (Back-260)
10.8
10.0
1
108.0
1 0.48
0.19
Insect Screen (default)
27
Window
350d Wall 6 (Right-350)
5.3
10.0
1
53.0
0.48
0.19
Insect Screen (default)
26
Window
350d Wall 6 (Right-350)
10.8
10.0
0.324
35.0
1 0.48
0.19
Insect Screen (default)
'"'- a R T
Inc,,
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1 R-PRF-01
Page 8 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xmi
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
D3
10
0.1
10
10
0
0
0
0
0
0
0
0
0
58
10
0.1
10
10
0
0
0
0
0
0
0
0
0
23
18
0.1
18
18
0
0
0
0
0
0
0
0
0
E2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
24
10
0.1
10
10
0
0
0
0
0
0
0
0
0
E1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
50
10
0.1
10
10
0
0
0
0
0
0
0
0
0
46
10
0.1
10
10
0
0
0
0
0
0
0
0
0
582
10
0.1
10
10
0
0
0
0
0
0
0
0
0
242
10
0.1
10
10
0
0
0
0
0
0
0
0
0
37
10
0.1
10
10
0
0
0
0
0
0
0
0
0
38
10
0.1
10
10
0
0
0
0
0
0
0
0
0
42
10
0.1
10
10
0
0
0
0
0
0
0
0
0
28
10
0.1
10
10
0
0
O
0
0
0
0
0
0
27
8
0.1
8
8
0
0
0."'
0
0
0
0
0
0
26
6
0.1
6
6
0
0
0
0
0
0
0
0
0
Registration Number: 215-NO2022856-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CFi R-PRF-01
Page 9 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-value
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofmaster
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
• Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgreat room
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooffamily
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofguest4
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooflounge
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof3
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Registration Number: 215-N0202265B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 ' - 10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CFI R-PRF-01
Page 10 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Covered Slab
master
862
100
None
0.8
No
Covered Slab 2
great room
1882
88
None
0.8
No
Covered Slab 3
family
1462
166
None
0.8
No
Covered Slab 4
guest-4
900
121
None
0.8
No
Covered Slab 5
lounge
850
55
None
0.8
No
Covered Slab 6
3
850
83
None
0.8
No
Covered Slab 7
2
850
83
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 112
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.66
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/2
—
---
---
---
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14;55 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1R-PRF-01
Page 11 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xml
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 1 mstr1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC 2 grt2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fary2
Air Distribution System 2
HVAC 3 fam3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC 44
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC 55
Other Heating and Cooling
System
Heating Component 5
Cooling Component 5
HVAC Fan 5
Air Distribution System 5
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 5
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 215-NO202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
CF1 R-PRF-01
Page 12 of 15
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13.1
16.7
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 3
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 4
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
Cooling Component 5
SplitAirCond
13.1
16.7
Zonally Controlled
Single Speed
Cooling Component
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
150
Required
Required
Required
Cooling Component 3-hers-cool
Required
150
Required
Required
Required
Cooling Component 4-hers-cool
Required
150
Required
Required
Required
Cooling Component 5-hers-cool
Required
150
Required
Required
Required
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14;55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack
Calculation Description: Title 24 Analysis
Calculation Date/Time: 17:08, Wed, Aug 05, 2015
Input File Name: Ratpack-Stein-15.xml
CFI R-PRF-01
Page 13 of 15
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsinAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1-hers-dist
Air Distribution System 2
LowLICod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
2-hers-list
Air Distribution System 3
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctSInAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
4-hers-dist
Air Distribution System 5
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
5-hers-list
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handier
Air Distribution System 1-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 2-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
Air Distribution System 3-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 4-hers-dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
Air Distribution System 5-hers-disc
Required
6.0
Required
Not Required
Not Required
Not Required
HVAC -FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.58
HVAC Fan 5-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation DatelTime: 17:08, Wed, Aug 05, 2015
Calculation Description: Title 24 Analysis Input File Name: Ratpack- Stein- 15.xm1
CF1 R-PRF-01
Page 14 of 15
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
HVAC Fan 5-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
121.56
0.25
Default
0
Required
COOLING VENTILATION
01
02
03
04
05
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Total Wafts
Number of Fans
WH Fan 1
61
0.52459
32
1
WH Fan 2
61
0.52459
32
1
WH Fan 3
61
0,52459
32
1
WH Fan 4
61
0.52459
32
1
WH Fan 5
61
0.52459
32
1
PROJECT NOTES
The Madison Club
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: Ca10ERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-07082015-744 Report Generated at: 2015-08-05 17:10:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Ratpack Calculation Date/Time: 17:08, Wed, Aug 05, 2015
CF1 R-PRF-01
Page 15 of 15
Calculation Description: Title 24 Analysis
Input File Name: Ratpack-Stein-15.xmi
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-08-05 17:14:55
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
..
Scott Design and Title 24, Inc.
2015-08-05 17:14:55,�
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N0202285B-000000000-0000 Registration Date/Time: 2015-08-05 17:14:55 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-05 17:10:12
1
I
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Ratpack Residence
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family ❑ F)dsting+ Addition/Alterabon
Date
8/5/2015
Project Address
53-525 Humbolt Blvd. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,6
Addition
n/a
# of Units
1
INSULATION
Construction Type
Cavi
Area
(ft) Special Features
Status
Roof Wood Framed Attic
R 38
7,656 Cool Roof
New
Wall Wood Framed
R 21
12, 627
New
Slab Unheated Slab -on -Grade
- no insulation
7,656 Perim = 696'
New
Demising Wood Framed
R 13
4,160
New
Door Opaque Door
- no insulation
0
New
FENESTRATION
Orientation Area(ft2)
Total Area: 3,589 Glazing Percentage: 46.9 %
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor:
Exterior Shades
0.45
Status
Left (S) 126.9
0.340
0.25 10.0
none
Bug Screen
New
Left (S) 107.8
0.340
0.25 none
none
Bug Screen
New
Left (S) 310.0
0.480
0.19 none
none
Bug Screen
New
Rear (IM 223.0
0.480
0.19 none
none
Bug Screen
New
Right (N) 350.4
0.340
0.25 none
none
Bug Screen
New
Right (N) 297.0
0.480
0.19 none
none
Bug Screen
New
Front (E) 518.0
0.480
0.19 10.0
none
Bug Screen
New
Front (E) 51.3
0.340
0.25 none
none
Bug Screen
New
Left (S) 77.0
0.480
0.19 18.0
none
Bug Screen
New
Rear (IM 236.5
0.380
0.23 10.0
none
Bug Screen
New
Rear (IM 52.0
0.340
0.25 none
none
Bug Screen
New
Rear (VIM 194.8
0.340
0.25 10.0
none
Bug Screen
New
Right (N) 24.0
0.350
0.30 none
none
Bug Screen
New
Front (E) 55.0
0.940
0.49 none
none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat
Status
1 Central Furnace
80% AFUE
Split Air Conditioner 16.7 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner 16.7 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner 16.7 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R-Value
Status
HVAC 1 mstr Ducted
Ducted
Conditioned
8.0
New
HVAC 2 grt Ducted
Ducted
Conditioned
8.0
New
HVAC 3 lam Ducted
Ducted
Conditioned
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution
Status
2 Small Storage Gas
50
0.68
All Pipes Ins
New
Ene Pro 6.7 by EnerqySoft User Number. 6712
RunCode: 2015-08-05T20:29:00
ID:
Page 18 of 48
1
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Ratpack Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ E)dsting+ Addition/Alteration
Date
81512015
Project Address
53-525 Humbolt Blvd. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,656
Addition
Na
# of Units
1
INSULATION
Construction Type
Area
Cavity (ff) Special Features
Status
FENESTRATION I Total Area: 3,589 Glazing Percentage: 46.9 New/Altered Average U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades
0.45
Status
Front (E) 20.0 0.480
0.19 none none Bug Screen
New
Left (S) 55.0 0.940
0.49 none none Bug Screen
New
Left (S) 458.0 0.480
0.19 10.0 none Bug Screen
New
Rear (W) 344.5 0.480
0.19 10.0 none Bug Screen
New
Right (N) 53.0 0.480
0.19 8.0 none Bug Screen
New
Right (N) 35.0 0.480
0.19 6.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 80% AFUE
Split Air Conditioner 16.7 SEER Setback
New
1 Central Furnace 80% AFUE
Split Air Conditioner 16.7 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value
Status
HVAC 4 Ducted
Ducted Conditioned 8.0
New
HVAC 5 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
EnergyPro, 6.7 by EnergySoft User Number. 6712
RunCode: 2015-08-05T20.29:00 ID:
Pa - a 19 of 46
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
rmmnlinnre nnnrnnrh aced F.rrentinm mnv annly_ Review the respective code section for more information
Building Envelope Measures:
§ 110.6(a)l:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
Fenestration products (except field -fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
§ 110.6(a)5:
Coefficient SHGC , and infiltration that meets the requirements of § 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
§ 110.8(i):
installation of a cool roof is specified on the CF1R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U-factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ 150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R-value.
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U-
§ 150.0(c):
factor).
§ 150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U-factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ 150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
§ 150.0(q):
factor of 0.58; or the weighted average U-factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
§ 150.0(e)1B:
equipped with a readily accessible, operable, and tight -fitting er or a combustion -air control device.
§ 150.0(e)1C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
§ 150.0(e)2:
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
§ 110.3(c)5:
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
§ 150.0(h)l:
in 150. 2.
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
§150.00)1A:
with insulation having an installed thermal resistance of R-12 or greater.
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
§150.00)1B:
insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.06)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
1
Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating
§ 150.00)2C:
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ 150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ 150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
§ 150.0(n)3:
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m) l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross -sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
§ 150.0(m)3-6:
requirements specified for duct construction; duct insulation R-value ratings; duct insulation thickness; and duct labeling.
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
§ 150.0(m)7:
dampers.
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
§ 150.0(m)8:
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
§ 150.0(m)9:
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)l l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
§ 150.0(m)15:
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
§ 150.0(o)IA:
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
1
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
§ 110.4(b)1 •
and return lines, or built-up connections for future solar heating
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run onl_v during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ 150.0(k)lA•
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
§ 150.0(k)1B:
with the applicable provisions of § 150.0
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1 C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
§ 150.0(k)1F:
requirements of § 150.0
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor fimction if the control is installed to comply with § 150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it fimctions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)211
fimctions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150. 2.
§ 150.0(k)2L•
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in 150. k 2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory, have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below, and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing fimction and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the followin methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the fimcMionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)9C•
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
§ 150.0(k)9D:
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141:0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 through 110.1 e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building o'ect and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
§ 110.10(c):
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system-
§110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
firture solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
il
1
1
I
I
I
J
i
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ratpack Residence
Date
8/5/2015
System Name
HVAC 1 mstr
Floor Area
862
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 861
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 129
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
16,928
1,231
453
19,305
Total Output (Btuh)
89,000
0
Output Btuhfs
103.2
245
230
Cooling System
0
0
Output per System
59,000
5,7 44
3,291
129
6,315
Total Output Btuh
59,000
2,943
245
1 26,125
4,523
-2,943
Total Output Tons
4.9
230
Total Output (Btuhfs
68•4
Total Output s on
175.3
23,136
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ACC760/58PH" l 10
48,523
0
89,000
89,000
Jan 1 AM
Airflow cfmfs
2•32
Airflow (cfmfTon)
406.8
Outside Air (%)
6•5 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
48,523
0
Outside Air (cfmfs )
0.15
Note: values above given at ARI.conoldons
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
129 cf n
72 OF
70 OF 112 OF 112 OF
Heating Coil Supply Fan 112 OF
2,000 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78OF 73/60OF 74/60OF 51 /50OF
Outside Air -A V- ETA
129 chn Supply Fan Cooling Coil 52 150 OF
2,000 cfrn
48.5 % ROOMNNW
Mo
70 / 58 °F 70 / 58 OF
Enen7yPro 6.7 by EnergySoff
User Number. 6712 RunCode: 2015-08-05T20:29:00 ID:
Page 24 of 48
1
1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ratpack Residence
Date
8/5/2015
System Name
HVAC 2 grt
Floor Area
1,882
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 2,259
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 282
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
36,337
2,688
851
33,239
Total Output (Btuh)
89,000
0
Output Btuhfs
47.3
0
0
Cooling System
0
0
Output per System
59,000
12,618
5,497
282
13,820
Total Output Btuh)
59,000
2,943
8,185
-2,943
Total Output (Tons)
4.9
01
0
Total Output (Btuhfsgft)
31.3
Total Output s on
382.8
51,898
44,115
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ACC760/58PH-110
47,738
3,415
89,000
Airflow (cfm/s
1.06
Airflow cfmfTon)
406.8
Outside Air %
14-1 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
47,738
3,415
89,000
Outside Air cfnVsgft
0.15
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
282 cfm
72 OF
67 OF 109 OF 109 OF
I 0 r' G
Supply Fan
Heating Coil
2,000 cfrn
109 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112 178 OF 76163 OF 77 / 63 OF 55 / 54 OF
Outside Air
282 cFm Supply Fan Cooling Coil 55 / 54 OF
2,000 cfm
%.3 % ROOM
70/60OF 70/60OF
4 0- .0 — ',-] J
EnergyPro 6.7 by EnergySoft
User Number. 6712 RunCode: 2015-08-05T20:29:00 ID:
Page 25 of 48
I
1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ratpack Residence
Date
8/5/2015
System Name
HVAC 3 fam
Floor Area
1,462
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,712
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 219
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
29,770
2,088
841
33,833
Total Output (Btuh)
89,000
0
O ut Btuhls
60.9
431
402
Cooling System
0
0
Output per System
59,000
9,755
4,825
219
10,692
Total Output (Btuh
59,000
2,943
6,913
-2,943
Total Output (Tons)
4.9
431
402
Total Output (Stuh/sgft)
40.4
Total Output s on
297.4
1 43,330
42,385
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ACC760/58PH-110
48,331
1,784
89,000
Airflow (cfm/sgft)
1.37
Airflow (cfm/Ton)
406.8
Outside Air (%)
11.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
48,331
1,784
89,000
Jan 1 AM
Outside Air (cfm/s
0.15
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
219 cfcfmHeating
72 OF
68 OF 110 OF 110 OF
10
LTIBA
Coil Supply Fan
2,000 cfm
110 OF
ROOMjog
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
peak
112 l 78 OF 75 l 62 OF 76 / 62 OF 53 / 52 OF
Outside Air
219 ctrn Supply 1 Fan Cooling Coil
2,000 cfm
70 / 59 OF
54 / 52 OF
53.0% ROOM
70 159 OF
EnergyPro 6.7 by EnefgySoft User Number. 6712 RunCode: 2015-08-05T20:29.00
!D.
Page 26 of 48
i
1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Ratpack Residence
8/5/2015
System Name
Floor Area
HVAC 4
1,750
ENGINEERING CHECKS
SYSTEM LOAD
Number of S tams
1
COIL
CFM
Total Room Loads 2,062
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 263Ll
Supply Fan
Supply Air Ducts
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
33,409
2,500
1,020
39,870
Total Output (Btuh)
89,000
0
Output Btuh/s
50.9
483
474
Cooling System
0
0
Output per System
59,000
5,280
263
12,788
Total O ut (Btuh)
59,000
-2,943
Total Output (Tons)
4.9
474
Total Output (Btuh/sgft)
33•7
TOTAL SYSTEM LOAD
7,780
Total Output s on
355.9
48,989
50,663
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ACC760/58PH-110
47,983
2,919
89,000
Airflow cf nls
1.14
Airflow cf n/Ton)
406.8
Outside Air (%)
13.1 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1 47,983
2,919
89,000
Outside Air (cfrn/sgft)
0.15
Note: values above given at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
67 OF 109 OF 109 OF
Outside Air
263 cfm
Heating Coil Supply Fan
109 OF
2,000 cfrn
--
ROOM
72 OF
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF 76/63OF 77/63OF 55/53OF
Outside Air
263 cfm
Supply Fan Cooling Coil
55 154 OF
AL
2,000 cfm
55.5
"/o ROOM
70160 OF
4— —
4 L
70 / 60 OF
EnergyPro 6.7 by EnergySoft
User Number. 6712 RunCode: 2015-0ti45T20:29:00
ID:
Page 27 of 48
1
1
1
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Ratpack Residence
Date
8/5/2015
System Name
HVAC 5
Floor Area
1,700
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,790
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 255
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
89,000
29,424
2,428
915
35,981
Total Output (Btuh)
89,000
0
Output Btuh/s
52.4
426
428
Cooling System
0
0
Output per System
59,000
11,343
5,217
255
12,429
Total Output (Btuh
59,000
2,943
426
44,563
7,645
-2,943
Total Output (Tons)
4.9
428
Total Output (Btuhlsgft)
34•7
Total Output s on
345.8
46,322
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow(eft)
2,000
Carrier 24ACC760/58PH-110
48,022
2,736
89,000
Airflow cfrnls )
1.18
Airflow cf nrron)
406.8
Outside Air (%)
12.8 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
48,022
2,736
89,000
Outside Air cfm/sgft)
0.15
Note: values above viven at ARI conditions
Aug 3 PM
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of HeatingPeak
26 OF
Outside Air
255 cfrn
72 OF
-4-- A
67 OF 109 OF 109 OF
G
LEHI���
Heating Coil Supply Fan
2,000 cfm
A 4
109 OF
Room
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78OF 76/62OF 77/63OF 54/53OF
Outside Air �a ---
-4 r w
255 corn Supply Fan Cooling Coil 55153 OF
2,000 cfrn
55.1 % ROOM
70 ! 60 OF 70 / 60 OF
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 ID:
Page 28 of 48
ROOM LOAD SUMMARY
Ratpack Residence 1 81512015
HVAC 1 mstr 862
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible
1 master Master Bedroom 1 861 16,928 1,231 861 16,928 1,231 453 J9,305
PAGE TOTAL
TOTAL*
861
16,928
1,231
453
19,305
861
16,928
1,231
453
19,305
Total includes ventilation load for zonal systems.
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20.29:00 1D: Page 29 of 48
I
ROOM LOAD SUMMARY
Project Name Date
Ratpack Residence 81512015
System Name Floor Area
HVAC 2 9ft 1,882
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent CFM Sensible
great room Great Dining Ki chen 1 Z 259 36,3371 Z 688 Z 25 36,3371 Z 688 851 33, 239
PAGE TOTAL
TOTAL*
for zonal
2,2591
36,3371
Z 688
651
33,239
27259
F 36,3371
2,6881
851
33,239
I
EnerayPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-08-05T20:29:00 ID. Page 30 of 48 1
ROOM LOAD SUMMARY I
Ratpack Residence 8/5/2015
System Name Floor Area
HVAC 3 fam 1,462
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
family Family Entry Hidden Mc 1 1,712 29,7701 2,088 1,7121 29,7701 Z088 841 33,833
PAGE TOTAL
TOTAL'
' Total includes ventilation load for
1,712
29,770
Z088
841
33,833
1,7121
29,7701
Z 088
841
33,833
I
Enen7yPro 6.7 by EnergvSolt User Number. 6712 RunCode: 2015-08-05T20.29.00 10: Page 31 of 48
ROOM LOAD SUMMARY
Project Name Date
Ratpack Residence 81512015
System Name Floor Area
HVAC 4 1,750
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible
guest-4 Guest Rooms 1 1,112 18,020 1,285 1,112 18,020 1,285 580 2Z683
lounge Lounge room 1 950 15,389 1,214 950 15,389 1,214 440 17,187
PAGE TOTAL
TOTAL'
` Total includes ventilation load for
Z 062
33,4091
Z 500
1,0201
39,870
2, 062
33,4091
2,5001
1,020
39,870
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 32 of 48
1
I
ROOM LOAD SUMMARY
Project Name
RatDack Residence
HVAC 5
ROOM LOAD SUMMARY
ROOM COOLING PEAK
Zone Name Room Name Mult. CFM Sensible Latent
3 Suite 3 1 975 16,034 1,214
2 Suite 2 1 814 13,390 1,214
PAGE TOTAL
TOTAL*
" Total includes ventilation load for zonal systems.
81512015
Floor Area
1,700
COIL COOLING PEAK I COIL HTG. PEAK
CFM Sensible Latent CFM Sensible
975 16,034 1,214 496 19,502
814 13,390 1,214 419 16,479
1,790
29,424
Z 428
915
35,981
1, 790
29,424
Z 428
915
35,9811
IEnergvPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID_ Page 33 of 48 1
1
I
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
Date
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Bedroom
Floor Area 862.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area
R-38 Roof Attic 862.0
R-21 Wall (W..21.2x6.16) 1,842.0
be LowE METAL .34/.25 115.0
opp LowE METAL .48/.19 253.0
Slab -On -Grade Perim = 100.0
'R-13 Wall 452.0
Items shown with an asterisk (') denote conduction through an interior surface
Infiltration:[ 1.00 X 1.064 X 862 X
Schedule Air Sensible Area
Fraction
U-Value
AT OF Btu/hr
46 = 1,031
46 ❑ 5,847
46 = 1,799
46 = 5,586
46 = 3,358
0 c 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 17,620
/ 60 ] X 46 = 1,685
AT
X
0.0260
X
X
X
0.0690
X
X
0.3400
X
0.4800
X
X
0.7300
X
X
0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
9.00 X 0.266
Ceiling Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 19,305
EneWPro 6.7 by EnergySoft User Number. 6712 RunCode. 2015-08-05T20:29:00 ID: Page 34 of 48
1
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
Date
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Great Dining Kitchen
Floor Area 1,882.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U-Value
1,882.0 X 0.0260
1,651.8 X 0.0690
292.0 X 0.4800
520.7 X 0.3400
236.5 X 0.3800
24.0 X 0.3500
perm = 88.0 X 0.7300
721.0 X 0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to another room
X 1,882 X 9.00 X 0.266
Area Ceiling Height ACH
AT *F
Btu/hr
= Z251
= 5,243
= 6,447
= 8,144
= 4,134
= 386
= Z955
= 0
=
=
=
=
=
=
=
=
=
29,560
46 = 3,678
R-38 Roof Attic
X
46
R-21 Wall (W.21.2x6.16)
X
46
opp LowE METAL .481..19
X
46
fx LowE METAL .34/.25
X
X
46
dr LowE METAL ..38/.23
46
Double Metal Tinted
X
46
Slab -On -Grade
X
46
*R-13 Wall
X
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Page Total
/ 60 ] X
AT
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 33,239
EneWPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05 0:29.00 ID: Page 35 of 48
ROOM HEATING PEAK LOADS
Project Name
Date
Ratpack Residence
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Family Entry Hidden Kitchen
Time of Peak
Jan 1 AM
Floor Area
1,462.0 ft2
Outdoor Dry Bulb
Temperature
26 OF
Indoor Dry Bulb Temperature
72 OF
Conduction
Area
U-Value
AT
°F
Btu/hr
R-38 Roof Attic
1,462.0
X
0.0260 X
46 =
1,749
R-21 Wall (W.21.2x6.16)
3,455.5
X
0.0690 X
46 =
10,968
Custom Entry Door
110.0
X
0.9400 X
46 =
4,756
opp LowE METAL .481.19
222.0
X
0.4800 X
46 =
4,902
fx LowE METAL .341.25
193.5
X
0.3400 X
46 =
3,026
Slab -On -Grade
perim = 166.0
X
0.7300 X
46 =
5,574
"R-13 Wall
822.0
X
0.1020 X
0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Items shown with an asterisk (') denote conduction through an interior surface to another room
Page Total
30,975
Infiltration•[ f.00 X 1.064 X 1,462 X 9.00
X 0.266
/ 60 ]
X 46
= 2,857
Schedule Air Sensible
Area
Ceiling Height
ACH
AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM
33,833
EnergyPro 6.7 by EnergySoR User Number. 6712
RunCode: 2015-08-05T20:29:00
ID:
Page 36 of 48
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Guest Rooms Time of Peak
Floor Area 900.0 ft2 Outdoor Dry Bulb Temperature
Indoor Dry Bulb Temperature 72 OF
Conduction Area U-Value
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
opp LowE METAL .481..19
fx LowE METAL .34/.25
Slab -On, -Grade
'R-13 Wall
900.0
2,100.0
396.0
24.0
perim = 121.0
6W.0
0.0260
0.0690
0.4800
0.3400
0.7300
0.1020
AT °F
8/5/2015
Jan 1 AM
26 OF
Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total L
Infiltration•[ 1.00 X 1.064 X 900 X 9.00 X 0.266 / 60 ] X 46 =
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
Btu/hr
1,076
6,665
8,744
375
4,063
0
20, 924
1, 759
TOTAL HOURLY HEAT LOSS FOR ROOM 22, 683
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T2 .29:0 ID: Page 37 of 48
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
Date
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Lounge room
Floor Area 850.0 flz
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area
R-38 Roof Attic 850.0 X
R-21 Wall (W.21.2x6.16) 848.5 X
opp LowE METAL .48/.19 451.5 X
Slab-OrrGrade perim = 55.0 X
R-13 Wall 511.0 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (") denote conduction through an interior surface to
Infiltration: 1.00 X 1.064 X 850 X
Schedule Air Sensible Area Ceiling
Fraction
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F Btu/hr
46 = 1,017
46 = Z693
46 = 9,969
46 = 1,847
0= 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 15,526
/ 60 ] X 46 = 1,661
AT
0.0260
0.0690
0.4800
0.7300
0.1020
another room
9.00 X 0.266
Height ACH
TOTAL HOURLY HEAT LOSS FOR ROOM 17,187
EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29:00 ID: Page 38 of 48
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
Date
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Suite 3
Floor Area 850.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction Area
R-38 Roof Attic 850.0
R-21 WaH (W.21.2x6.16) 1,313.0
opp LowE METAL .48/.19 447.0
Slab -On -Grade perim = 63.0
*R-13 Wall 485.0
Items shown with an asterisk (') denote conduction through an interior surface
Infiltration:[ 1.00 X 1.064 X 850 X
Schedule Air Sensible Area
Fraction
U-Value
X 0.0260
X 0.0690
X 0.4800
X 0.7300
X 0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to another room
9.00 X 0.266
Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
Btu/hr
46
=
1,017
46
=
4,167
46
=
9,870
46
=
=
2,787
0
0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total
/ 60 ] X 46
AT
17,841
= 1,661
TOTAL HOURLY HEAT LOSS FOR ROOM 19,502
EnergyPro 6.7 by EnergySoR User Number. 6712 RunCode: 2015-08-05T20.29.00 ID: Page 39 of 48
J
I
ROOM HEATING PEAK LOADS
Project Name
Ratpack Residence
Date
8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Suite 2
Floor Area 850.0 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area U-Value
850.0 X 0.0260
1,416.0 X 0.0690
274.0 X 0.4800
30.0 X 0.3400
perim = 83.0 X 0.7300
511.0 X 0.1020
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
through an interior surface to another room
X 850 X 9.00 X 0.266
Area Ceiling Height ACH
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F Btu/hr
46 = 1,017
46 = 4,494
46 = 6,050
46 = 469
46 = 2, 787
0 = 0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Page Total 14,817
/ 60 ] X 46 = 1,661
AT
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
opp LowE METAL .48/.19
fx LowE METAL .34/.25
Slab -On -Grade
*R-13 Wall
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 16,479
Ene►gyPm 6.7 by EnergySoft User Number. 6712 RunCode: 2015-08-05T20:29.00 Q Page 40 of 48
1
1
1
1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area
862.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Attic
(1M 862.0 X 0.0260
X
56.0 =
1,255
R-21 Wall (W.21.2x6.16)
(E) 150.0 X 0.0690
X
32.1 =
332
R-21 Wall (W 21.2x6.16)
(S) 593.2 X 0.0690
X
27.1 =
1,110
R-21 Wall (W 21.2x6.16)
(169 305.0 X 0.0690
X
32.6 =
685
R-21 Wall (W.21.2x6.16)
(N) 793.8 X 0.0690
X
29.0 =
1,588
*R-13 Wall
452.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
4,971
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
D3
(S) 31.8 X 16.1 +
0.0
X 17.4 =
511
D2
(S) 0.0 X 16.1 +
41.0
X 17.4 =
713
22
(S) 0.0 X 16.7 +
54.0
X 17.7 =
953
21
(1M 0.0 X 16.7 +
135.0
X 27.5 =
3,714
D1
(N) 0.0 X 16.1 +
30.2
X 24.1 =
728
20
(N) 0.0 X 16.7 +
64.0
X 22.8 =
1,457
C2
(N) 0.0 X 16.1 +
12.0
X 24.1 =
269
X +
X =
F=�
X +
X =
Page Total
8,36
Internal Gain
Btu/hr
Occupants
2 6 Occupants X 245
Btuh/occ.
=
634
Equipment
862 Floor Area X 0.50
w/sgft
=
1,471
Infiltration: 1.064
X 0.94 X 35.55 X 42 =
1,486
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,928
Latent Gain
Btulhr
Occupants
2 6 Occupants X 155
Btuh/occ.
=
401
Infiltration: 4,771
X 0.94 X 35.55 X 0.00523 =
830
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
401
Ene Pro 6.7 by EnerpySoft
User Number. 6712 RunCode: 2p15-08-05T20:29:00 ID:
Page 41 of 48
1
1
I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Ratpack Residence 1 8/5,2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Great Dining Kitchen
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,882.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
R-38 Roof Attic
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W.21.2x6.16)
R-21 Wall (W..21.2x6.16)
*R-13 Wall
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,882.0
0.0260
W.0
433.7
0.0690
32.1
241.1
0.0690
27.1
641.7
0.0690
32.6
335.3
0.0690
29.0
721.0
0.1020
0.0
Page Total
Items shown with an asterisk (*) denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Fenestration
58
G4
G3
G2
23
E2
24
G1
E1
Orientation
Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
131.E
16.7
83.4
0.0
16.1
51.3
0.0
16.1
1&0
0.0
16.1
18.8
77.0
16.7
0.0
95.1
16.1
0.0
203.8
16.1
32.7
0.0
16.1
52.0
122.3
16.1
72.5
5.6 Occupants X 245 Btuh/occ.
1,882 Floor Area X 0.50 W/so
Btu/hr
2,740
961
451
1,441
1 6711
X
X
X
X
X
X
XEl
X
X
GLF
=
=
=
-
=
=
-
=
-
Btu/hr
26.8
4,425
29.4
1,509
17.4
313
17.4
327
1,282
1,529
4,246
1,579
4,168
Page Total
19,37
Btu/hr
= 3„
Infiltration: X X 77.62 X F 3,245
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 36,337
Latent Gain Btu/hr
Occupants 5.6 Occupants X 155 Btuh/occ. = 875
Infiltration: 4,771 X 0.94 X 77.62 X 0.00523 =
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM d751
1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Great Dining Kitchen
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,882.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD�
Btu/hr
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
0
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btufhr
G6
(N) 0.0 X 16.1 +
27.4 X 24.1
= 661
G5
(N) 0.0 X 16.1 +
63.3 X 24.1
= 1,527
D51
(N) 0.0 X 18.1 +
24.0 X 27.8
= 667
X +
X
=
X +
X
=
X +
X
—
X +
X
=
X +
X
=
X +
X
=
Page Total
Z854
Internal Gain
Btu/hr
Occupants
5 6 Occupants X 245
Btuh/occ. =
1,363
Equipment
1,882 Floor Area X 0.50
w/sgft =
3,212
Infiltration: 1.064
X 0.94 X 77.62 X 42 =
3,245
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
36,337
Latent Gain
Btu/hr
Occupants
5 6 Occupants X 155
Btuh/occ. =
875
Infiltration: 4,771
X 0.94 X 77.62 X 0.00523 =
1,813
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
875
Ene Pro 6.7 by EnerqySoft
User Number. 6712 RunCode: 2015-08-05T20.29:00 1D.
Page 43 of 48
1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Family Entry Hidden Kitchen
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,462.0 tt2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD�
Btu/hr
R-38 Roof Attic
AM 1,462.0 X 0.0260
X 56.0 =
2,129
R-21 Wall (W.21.2x6.16)
(E) 825.0 X 0.0690
X 32.1 =
1,828
R-21 Wall (W.21.2x6.16)
(S) 892.0 X 0.0690
X 27.1 =
1,669
R-21 Wall (W.21.2x6.16)
(lN) 150.0 X 0.0690
X 32.6 =
337
R-21 Wall (W.21.2x6.16)
(N) 1,588.5 X 0.0690
X 29.0 =
3,179
*R-13 Wall
822.0 X 0.1020
X 0.0 =
0
X
X =
X
X =
X
X =
Page Total
9,141
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area GLF
Btu/hr
01
(E) 0.0 X 37.0 +
55.0 X 63.1 =
3,471
D6
(E) 0.0 X 16.7 +
20.0 X 26.8 =
536
04
(S) 0.0 X 16.7 +
176.0 X 17.7 =
3,143
A
(S) 0.0 X 37.0 +
55.0 X 39.6 =
Z 177
C1
(N) 0.0 X 16.1 +
16.5 X 24.1 =
398
13
(N) 0.0 X 16.7 +
24.0 X 22.8 =
546
8
(N) 0.0 X 16.1 +
177.0 X 24.1 =
4,269
X +
X =
X +
X =
Page Total
14,53
Internal Gain
Btu/hr
Occupants
44 Occupants X 245
Btuh/occ. =
1,075
Equipment
1,462 Floor Area X 0.50
W/sq{ =
2,495
Infiltration: 1.064
X 0.94 X 60.30 X 42 =
2,521
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
29,770
Latent Gain
Btu/hr
Occupants
4 4 Occupants X 155
Btuh/occ. =
680
Infiltration: 4,771
X 0.94 X 60.30 X 0.00523 =
1,408
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
680
Enem YPro 6.7 by EnerqySoft
User Number. 6712 RunCode: 2015-08-05T20:29:00 ID:
Page 44 of 48
1
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Guest Rooms
Outdoor Dry Bulb Temperature
112 OF
Floor Area
900.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Attic
AM 900.0 X 0.0260
X
56.0 =
1,310
R-21 Wall (W.21.2x6.16)
(E) 525.0 X 0.0690
X
32.1 =
1,163
R-21 Wall (W.21.2x6.16)
(S) 505.0 X 0.0690
X
27.1 =
945
R-21 Wall (W.21.2x6.16)
(tM 437.0 X 0.0690
X
32.6 =
962
R-21 Wall (W.21.2x6.16)
(N) 633.0 X 0.0690
X
29.0 =
1,267
'R-13 Wall
656.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
5,667
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
50
(S) 80.0 X 16.7 +
0.0 X
17.7 =
1,332
46
(S) 150.0 X 16.7 +
0.0 X
17.7 =
2, 498
45
I'M 0.0 X 16.7 +
88.0 X
27.5 =
2,421
44
(N) 0.0 X 16.7 +
43.0 X
22.8 =
979
43
(N) 0.0 X 16.7 +
35.0 X
22.8 =
797
51
(N) 0.0 X 16.1 +
24.0 X
24.1 =
579
X +
X
=
X +
X
=
X +
X
=
Page Total
8,60
Internal Gain
Btu/hr
Occupants
2.7 Occupants X 245
Btuh/occ.
=
661
Equipment
900 Floor Area X 0•50
W/sgft
Infiltration: 1.064
X 0.94 X 37.12 X 42 =
1,552
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,020
Latent Gain
Btu/hr
Occupants
2 7 Occupants X 155
Btuh/occ.
=
418
Infiltration: 4,771
X 0.94 X 37.12 X 0.00523 =
867
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
418
EnefpyPro 6.7 by EnerpySoft
User Number. 6712 RunCode: 2015-08-05T20.29:00 ID:
Page
45 of 48
J
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Lounge room
Outdoor Dry Bulb Temperature
112 OF
Floor Area
850.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btufhr
R-38 Roof Attic
850.0 X 0.0260
X
56.0 =
1,238
R-21 Wall (W.21.2x6.16)
(E) 435.0 X 0.0690
X
32.1 =
964
R-21 Wall (W.21.2x6.16)
(VlQ 413.5 X 0.0690
X
32.6 =
929
'R-13 Wall
511.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
3,130
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btufhr
56
(E) 131.E X 16.7 +
83.4
X 26.8 =
4,425
24
203.8 X 16.7 +
32.7
X 27.5 =
4,293
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
8,71
Internal Gain
Btu/hr
Occupants
2.5 Occupants X 245
Btuh/occ.
=
625
Equipment
850 Floor Area X 0•50
w/sgft
=
1,451
Infiltration: 1.064
X 0.94 X 35.06 X 42 =
1,465
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
15,389
Latent Gain
Btu/hr
Occupants
2 5 Occupants X 155
Btuh/occ.
=
395
Infiltration: 4, 771
X 0.94 X 35.06 X 0.00523 =
819
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
395
Ene Pro 6.7 by EnerpySoft
User Number. 6712 RunCode: 2015-08-05T20:29.00 ID:
Page 46 of 48
1
1
1
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
1 81512015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Suite 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
850.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD�
Btulhr
R-38 Roof Attic
(tM 850.0 X 0.0260
X
56.0 =
1,238
R-21 Wall (W.21.2x6.16)
(E) 472.0 X 0.0690
X
32.1 =
1,046
R-21 Wall (W.21.2x6.16)
(S) 472.0 X 0.0690
X
27.1 =
883
R-21 Wall (W.21.2x6.16)
(N) 369.0 X 0.0690
X
29.0 =
738
*R-13 Wall
485.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
3,905
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btulhr
37
(E) 53.9 X 16.7 +
34.1
X 26.8 =
1,811
38
(S) 150.0 X 16.7 +
0.0
X 17.7 =
Z498
42
(S) 78.0 X 16.7 +
0.0
X 17.7 =
1,299
35
(N) 0.0 X 16.7 +
78.0
X 22.8 =
1,775
36
(N) 0.0 X 16.7 +
53.0
X 22.8 =
1,206
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
8,58
Internal Gain
Btulhr
Occupants
2.5 Occupants X 245
Btuh/occ.
=LA
Equipment
850 Floor Area X 0.50
w/sgft
=
Infiltration: 1.064
X 0.94 X 35.06 X 42 =
1,465
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
16,034
Latent Gain
Btu/hr
Occupants77�1
2 5 Occupants X 155
Btuh/occ.
=
395
Infiltration: 4,771
X 0.94 X 35.06 X 0.00523 =
819
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
395
Ene Pro 6.7 by EnetpySolt
User Number. 6712 RunCode: 2015-08-05T20.29.00 ID:
Page
47 of 48
1
J
I
F
I
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Ratpack Residence
1 8/5/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Suite 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
850.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 RoofAttfc
(IAq 850.0 X 0.0260
X
56.0 =
1,238
R-21 Wall (W..21.2x6.16)
(S) 612.0 X 0.0690
X
27.1 =
1,145
R-21 Wall (W.21.2x6.16)
(IAA 392.0 X 0.0690
X
32.6 =
881
R-21 Wall (W.21.2x6.16)
(N) 412.0 X 0.0690
X
29.0 =
824
•R-13 Wall
511.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
4,087
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Stu/hr
32
(S) 0.0 X 16.7 +
78.0 X
17.7 =
1,377
F
(S) 0.0 X 16.1 +
30.0 X
17.4 =
522
28
(149 102.4 X 16.7 +
5.6 X
27.5 =
1,860
27
(N) 0.0 X 16.7 +
53.0 X
22.8 =
1,206
26
(N) 0.0 X 16.7 +
35.0 X
22.8 =
797
X +
X
=
X +
X
=
X +
X
=
X +
X
Page Total
5,76
Internal Gain
Stuthr
Occupants
2 5 Occupants X 245
Btuh/occ.
=
625
Equipment
850 Floor Area X 0.50
w/sgft
=
1,451
Infiltration: 1.064
X 0.94 X 35.06 X 42 =
1,465
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,390
Latent Gain
Btuihr
Occupants
2 5 Occupants X 155
Btuh/occ.
=
395
Infiltration: 4,771
X 0.94 X 35.06 X 0.00523 =
819
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
395
Ene 6.7 bv EnemySoft
User Number. 6712 RunCode: 2015-08-05T70:29:00 1D:
Pagg
48 of 48