BRES2015-0302 Geotechnical Update"I.
Engineering
45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
800 E. Florida Avenue, Hemet. CA. 92543 (951) 766-8777 Fax (951) 766-8778
August 10, 2015
Gordon Stein Design
74794 42^ 1 Avenue, Suite 9
Palm Desert, California 92260
Subject: Geotechnical Update
Project: Proposed Custom Residence
The Madison Club — Lot 66B
La Quinta, California
Project No. 54445187
15-08-329
Ref: Geotechnical Investigation Report prepared by Sladden Engineering dated January
28, 2005; Project No. 544-4810, Report No. 05-01-101
Report of Testing and Observation During Rough Grading prepared by Sladden
Engineering dated March 2, 2006; Project No. 522-4810; Report No. 06-02-120
As requested, we have reviewed the above referenced geotechnical reports as they relate to the
design and construction of the proposed custom residence to be to be constructed on Lot 66B
within the Madison Club development in the City of La Quinta, California. It is our
understanding that the proposed residential structure will be of relatively lightweight wood -
frame construction and will be supported by conventional shallow spread footings and concrete
slabs on grade.
The subject lot was previously graded during the rough grading of the Madison Club project site.
The rough grading included over -excavation and recompaction of the native surface soil along
with the placement of engineered fill material to construct the building pads. The site grading is
summarized in the referenced report of Testing and Observation During Rough Grading along
with the compaction test results.
Because the lot has been previously rough graded, the remedial grading required at this time
should be minimal provided that the building area that falls within the previously assu ped__.
building envelope. The building areas should be cleared of surface yei ptat on !kp �?� � _�
moisture conditioned prior to precise grading. The exposed suji rfaces lld"� n;lpkctrgd` o a
minimum of 90 percent relative compaction prior to fill placement. The previously removed soil
and any fill material should be placed in thin lifts at near optimum moisture rstc`Iand
compacted to at least 90 percent relative compaction. NCB
Sladden Engineering
August 10, 2015 -2- Project No, 544-1.5187
15-08-329
The referenced reports include recommendations pertaining to the construction of residential
structure foundations. The previous reports also address the potential for liquefaction,
subsidence and differential settlement. Based upon our review of the referenced reports, it is our
opinion that the structural values included in these reports remain applicable for the design and
construction of the proposed residential structure foundations.
The allowable bearing pressures recommended in the referenced Geotechnical Investigation
report remain applicable. Conventional shallow spread footings should be bottomed into
properly compacted fill material a minimum of 12 inches below lowest adjacent grade.
Continuous footings should be at least 12 inches wide and isolated pad footings should be at least
2 feet wide. Continuous footings and isolated pad footings should be designed utilizing
allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf
for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be
utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The
recommended allowable bearing pressures may be increased by one-third for wind and seismic
loading.
Lateral forces may be resisted by friction along the base of the foundations and passive resistance
along the sides of the footings. A friction coefficient of 0.48 times the normal dead load forces is
recommended for use in design. Passive resistance may be estimated using an equivalent fluid
weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance
should be reduced by one third to 0.33 times the normal dead load forces.
The bearing soil is generally non -expansive and falls within the "very low" expansion category in
accordance with the 2013 (CBC) classification criteria. Pertinent 2013 CBC Seismic Design
parameters are summarized on the following page.
Sladden has reviewed the 2013 California Building Code (CBC) and summarized the current
seismic design parameters for the proposed structure. The seismic design category for a structure
may be determined in accordance with Section 1613 of the 2013 CBC or ASCE7. According to the
2013 CBC, Site Class D may be used to estimate design seismic loading for the proposed
structures. The 2013 CBC Seismic Design Parameters are summarized below.
Risk Category (Table 1.604.5):1/11/111
Site CIass (Table 1613.3.2): D
Ss (Figure 1613.3.1):1.502g
S1 (Figure 1.613.3.1): 0.702g
Fa (Table 1613.3.3(1)): 1.0
Fv (Table 161.3.5.3(2)): 1.5
Sms (Equation 16-37 (Fa X Ss)):1.502g
Sm1 (Equation 16-38 (Fv X S1.1):1.053g
SDS (Equation 16-39 12/3 X Snis)): 1.001g
SD1 (Equation 16-40 (2/3 X Smi1): 0.702g
Seismic Design Category: D
Madden Engineering
August 10, 2015 -3- Project No. 544-15187
15-08-329
In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate
content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site
soil is generally considered corrosive with respect to concrete. The testing indicated soluble
sulfate content of 6400 ppm (0.640 percent) that corresponds with the " severe" exposure category
in accordance with ACT 318-08, Table 3. Based upon this, the use of sulfate resistant concrete
mixes will be required. Structural concrete in contact with the soil should have a minimum
compressive strength of 4000 psi and a maximum water -cement ratio of 0.50.
We appreciate the opportunity to provide service to you on this project. If you have any
questions regarding this letter or the referenced reports, please contact the undersigned.
Respectfully submitted,
SLADDEN ENGINEERING
Brett L. Anderson
Principal Engineer
ENGIrl -ERIi ?G
SER/gvm
Copies: 4/Gordon Stein Design
Slarlden Engineering
51-1M-1619'�
Please verify that soils reports contain all of the above information. In addition, to assure
continuity between the Investigation/reporting stage and the execution stage, please use
the following checklist to verify that the conclusions and recommendations in the report
cover all the required elements. Only then can we be assured that the construction
documents address all of the site soil conditions.
La Quinta Geotechnical Report Checklist
Does the °Conclusions and Recommendations" section of the report address each of the
following criteria?
"Address" means:
(a) the criterion is considered significant and mitigation measure(s) noted, or;
(b) the criterion is considered Insignificant and explicitly so stated.
Yes . No Criterion
❑ Foundation criteria based upon bearing capacity of natural or compacted soil.
❑ Foundation criteria to mitigate the effects of expansive soils.
j ❑ Foundation criteria based upon bearin capacity. of natural / g _ or compacted soil.
❑ Foundation criteria to mitigate the effects of liquefaction.
711
❑ Foundation criteria to mitigate the effects of seismically, Induced differential
settlement.
❑ Foundation criteria to mitigate the effects of long-term differential settlement.
❑ Foundation criteria to mitigate the effects of varying soil strength.
❑ Foundation criteria to mitigate expected total and differential settlement.
Any "No" answers to the .above checklist should be noted as specific required
corrections.
r
TABLE 19-A-2—REQUIREMENTS FOR SPECIAL EXPOSURE CONDITIMIS
MINIMUM
MAXIMUI I
• WATER:CE1MEftTR'IOUS
10!'k�
NORMAL'-WEAND .
LJGH fS'lEIGKF. -
MATERlAL9, RAho;'BY::'
AGGREGATI •CONCRETE,
EXPOSURE CONDMON
•WEIGHT,'NORMAL:WEIGHT•
AGGREGATE CONCRETE •
x a,t10689.tor 6iPa
Concrete intcndcd to have low permeability when
exposed to water
0.50
4,000
Conere)a exposed to*freezing and thawing in a moist
condition or to deicing chemicals
0.45
4,500 '
For Corrosion projection for reinforced concrete
exposed to chlorides from deicing ncmicals, salts or
brackish:watcr, orsprayftnm these "sources
0.40
S,OOG
TABLE 19-A-3--REQUIREMENTS•FOFJ CONC13ET-E
EXPOSED TO SULFb.TE•-CONTAI),llNr:-cnt:t IrtnmQ
NORMAL -WEIGHT
UrHME1GHT
AGGREGATE
AGGREGATE
=CONCRETE -
Mazlmvm'Watar-
CementlUou:
1, •Normal-
Velptt[•and
WATEP
SOLUBLE
SULFATE
l tdtarlalta ReUo,-by:.
11Qhtwdpht '
SULFATE
So) IN SOtt�
P RG AGE BY
We{Qhts..�
!'tOA
ADOro$lite.1
CO°te,,ps!
EXPOSURE
WEJGHY ,
SULFATE(SO4)IF{
WATER, pprn.
CEMENTTYPE
eht'
Concrete S
x G.6psagTorMPa.
Negligible
O.DG-4.10
Maderatc2•
1).1M20
150 1 500
11. IPCMS), iS
OSO
4,000
(MS)
Sevcrc
0.2Q 2 00
I SDO 1'G,OOG
V
0.45
4,500
Very mvem
Over 2.GG
Ovcr 10,DOG
V plus
0.45
4,500
-
-
pozzolan3
I A
.
u �� iu�rcc sclrngm may ocicquucd for low permeability-or forprotcction
Z against wrrosion'of embEddcd items or frcczing and thawing (fabl'_ 19=A-2)_
Seawater_
?PO=Olan that has been determined by test or service record to imprnvc sulfa
tautmg'I pc V ccmcnL ct resistance when usqcl in concrete con-
2-264
Slac9den
Engineering
6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847
450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863
Date: August 6, 2015
Account No.: 544-15187
Customer: MOX Design
Location: Madison Club, Lot 6613, La Quinta
Sulfate Series
Analytical Report
Soluble Sulfates
per CA 417
PPM
6400
Soluble Chloride
per CA 422
pprn
:Ii
Sulfate 544-15187 080615