Loading...
MUP 2025-0010 Outdoor Lighting - 80770 Vista Bonita Tr (01.12.2026)ta a iKra t %I 11 t tA\ A - January 12, 2026 Tim Ballard Discover Investments 3501 Jamboree Road, Suite 4200 Newport Beach, CA 92660 SUBJECT: MINOR USE PERMIT 2025-0010: 80770 VISTA BONITA TRAIL SPORT COURT LIGHTING Dear Mr. Ballard: The Design and Development Department has approved your request to install four (4) new light poles at a proposed sport court located at 80770 Vista Bonita Trail. Approval of this application is subject to the attached exhibits for the Minor Use Permit and the following Findings and Conditions of Approval: FINDINGS Consistency with the General Plan: The proposed light poles and sport court are consistent with the goals, objectives and policies of the General Plan, in that the proposed sport court and lights are designed to be compatible with adjoining properties with the addition of light shields that will direct light away from spreading to them. 2. Public Welfare: Approval of the proposed light poles will not create conditions materially detrimental to the public health, safety and general welfare. 3. The proposed new light poles at the proposed sport court will not create new adverse visual impacts. A hedge proposed along the rear property line is intended to screen the sport court and lights. CONDITIONS The applicant/property owner agrees to defend, indemnify, and hold harmless the City of La Quinta (the "City"), its agents, officers and employees from any claim, or litigation arising out of the City's approval of this project. This indemnification shall include any award toward attorney's fees. The City of La Quinta shall have the right to select its defense counsel in its sole discretion. The City of La Quinta shall promptly notify the applicant of any claim, action, or proceeding and shall cooperate fully in the defense. 2. The applicant shall comply with all provisions of La Quinta Municipal Code Section 9.60.150 "Tennis and other game courts." 3. A maximum of four (4) lights shall be permitted and the mounting standard height shall not exceed eighteen (18) feet measured from the court surface. Courts shall not be lighted after 10:00 p.m. taQaNfra CALIFORNIA - 4. The surface area of any game court shall be designed, painted, colored and/or textured to reduce the reflection from any light source. 5. Landscaping shall be installed and maintained between the sport court and property lines. 6. The applicant is permitted to install the equipment identified on the scope of work on the approved and attached plans for MUP2025-0010. 7. The applicant shall obtain all necessary building permits from the City's Building Division and is responsible for meeting all applicable plan check submittal requirements. This decision may be appealed to the Planning Commission by any party who submits the necessary paperwork and filing fee of $1,575.00 to this office within 15 days of the date of approval of this permit. The City may elect to add Conditions to this application request to mitigate any problems that arise not previously addressed herein. If you have any questions, please contact me at (760) 777-7069. Sincerely, Scott Nespor Senior Planner Design and Development cc: David Newell, Director of Design and Development h �Z rn P e a A WAY) (CRO ) p,a 5 U � Sz 6 nV 9y i� � ad� rmsi N88'19'SBE 3, .38' R 19,00 o A ui 19.06 .� 1 —�_ / uam umY[mmm W ¢z � W H d¢ ) I I h#s- mr 3 Cc O _rra Zco i f po � ¢ m ti 49, r PLANNING APPROVAL -@ ADMINISTRATIVE p CASE# MUP2025-0010 EXHIBIT# INITIAL snespor NE tieary�� ,0 035 N9— DATE 01/09/2026 4:38:35 PM 5� °--- (Gt0 ) °_ meortent Notice - Underground Service Alert L— wA+wW sneer• I.-� i�i nm °ac°wn°a".oi e". mamma° m°" a m`a"�pm.aro m o ,Y tell,a�xQa SCALE: 1 16" 1'-0" U,urc 10-25-25 SITE PLAN ALL R@ d F�WSA-i00 M Mq M roll-Acmwu�cul�mlm�t�oe�ww n,.w��� Yi�d�w-�Nb II e°'�i I-Y-Y.d..h w ah r.ia..wus iimxM � x.m h. m..Mgx. d PLANT LEGEND we�Y-a-r�o-y- IaY u'Sm s sm .m � rq-bww. ax �Mla�.e f' }� W Mr� Apnlmml. Ym .Y eo- a Sm a0 ¢ �pM'pue al,Y LOv em Rwt v IMx1x,1 .m w + � �m � eurmeee Ltae pih' � s qY. xx .m W��a® Ym 5eY fel s0 W ¢ Z ! rr i , �. as z o i ® a_,m 5 . .a. ,..w, ,d 5 ,.I .x .ao H ¢ � O F >o Z; J .a YIIV FAW14 - .1—A mU Ya11 ovem-seeaea vi I.I.—I y , m 3/8'minua 11% flow - 1— 111% 8 11— 811ck - aofl ItpbAlzw vet wtl compact ' Club Appproretl mulcM1 vlll be uaeE In iM1e fipnt mE Ma mar plant. 9 tbicx, (s,mnit ewcpie Iw opprowi prlw m Inetdlation ) 1 —AL STFIL FIG111 i5R LAVh AREAS ) rF— aRovh RE AL s,EEL E 5 R5 .oR pA,Rs E �.� 55: aa,x YA„y� �Li P rAY,S Y,u. a, ,IAR„1r repR�-RAC Apae�l. � NOTE: ALL TREES ARE TO BE PLANTED 10FROM SEPTIC TANK RCN90Y5 SEE SHEET L-6 FOR PLANTING DETAILS r=ATE"" SCALE: 1/16" 1'-0" 06-09-25 Specifications Construction: • The rugged, one-piece die-cast aluminum housing features a complete heat sink hat optimizes heat dissipation through convection cooling management. • Low profile, 3G vibration rated compact design minimizes wind load requirements. • Housing is completely sealed against moisture and environmental contaminants. Optics: • Available in IES Type II, III, IV, V distributions • Light engines are available in adjustable color temperature (3000K&4000K&5000K) configurations. • Scalable Lumen Packages from 6,600 to 61,000 Lumens replaces up to 1000W Metal Halide. • Optics is precisely designed to shape the distribution, maximizing efficiency and I' Medium Size: 100W/140W/180W enlo" Large Size: 250W/30OW/40OW app Icatlon spacing. • The optics can conform to dark sky requirement. Electrical: i nd" • Universal 120-277 VAC or 347-480 VAC input voltage • 10KA(@120-277V) or 20KA(@347-480V) surge protection • Standard with 0-10V dimming driver • Power adjustable: 100%, 80%, 60%, 40%. 3 • Power Factor: 2!90% WET LOCATION �� Controls: • Optional Occupancy sensor or Microwave sensor. • Optional Bluetooth sensor or Bluetooth controller. • Optional NEMA 3-pin photocell or 7-pin photocell. Ambient Temperature: • Ambient operating temperature -40°C to 45'C (-40T to 1130F). • The ambient temperature of 40OW is: -40°C to 40°C. Installation: • Suitable for mounting heights ranging from 26-50' in area lighting applications • Round pole, Square pole, slipfitter, wall mount and yoke are available. • The design can be operated by one person to install the whole lamp Lifespan: • Estimated 100,000-hour LED lifespan based on IES LM-80 results and TM-21 calculations Finish: • It's available in black or optional dark bronze, silvery gray or white. 0 Black Dark Bronze Silver Gray White Structural Design Housing The one-piece die-cast housing with corrosion -resistant coating protection and the modular design extend the life of the luminaire while making it easy to maintain. Optional Type II, TypeM, TypefV and Type V Photometry as per applications. Certifications: • ULwet location listed • DesignLights ConsortiumM Qualified. Note: DesignLights ConsortiumTM Qualified and classified for DLC Premium, refer to www.designlights.org for details. Note: Actual performance may differ as a result of end -user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C (±5 C ) specifications subject to change without notice. @ 49 Photocell Dusk to dawn controls can CCT &POWER Adjustable be utilized via optional NEMA twist -lock photocell. lumen output60%80%/100%),andthreeelectable /�Off—erlou,/,electable CC (30K/40K/SOK) Occupancy Sensor Optional occupancy sensor allows for security and energy saving. Optional for square,round pole mount,Slipfitter, wall mount, yoke mount. All mounting brackets are simple to operate, which can realize single operation and reduce labor costs. PERFORMANCE DATA CLLAL08100W SETTING SYSTEM WATTS DIST.TYPE CRI 3000K 4000K 5000K LUMENS LPW LUMENS LPW LUMENS LPW 2 70 145001m 1451mNV 158001m 1581mNV 150001m 1501mNV 100% 100W 3 70 145001m 1451m/W 158001m 1581m/W 150001m 1501m/W 4 70 145001m 1451mNV 158001m 1581mNV 150001m 1501mNV 5 70 151001m 1511m/W 160001m 1601m/W 156001m 1561m/W 2 70 120001m 1501mNV 130001m 1631m/W 125001m 1561m/W 80% 80W 3 70 120001m 1501mNV 130001m 1631mNV 125001m 1561m/W 4 70 120001m 1501mNV 130001m 1631mNV 125001m 1561m/W 5 70 125001m 1561mNV 133001m 1661m/W 128001m 1601m/W 2 70 93001m 1551mNV 100001m 1671m/W 96001m 1601m/W 60% 60W 3 70 93001m 1551mNV 100001m 1671m/W 96001m 1601m/W 4 70 93001m 1551m/W 100001m 1671mNV 96001m 1601mNV 5 70 96001m 1601mNV 102001m 1701mNV 98501m 1641mNV 2 70 64001m 1601mNV 68001m 1701m/W 65601m 1641m/W 40% 40VV 3 70 64001m 1601m/W 68001m 1701m/W 65601m 1641m/W 4 70 64001m 1601mNV 68001m 1701m/W 65601m 1641m/W 5 70 65601m 1641mNV 70001m 1751mNV 67001m 1681mNV CLLAL08140W SETTING SYSTEM WATTS DIST.TYPE CRI 3000K 4000K 5000K LUMENS LPW LUMENS LPW LUMENS LPW 2 70 200001m 1471m/W 230001m 1641mNV 210001m 1501mNV 100% 140W 3 70 200001m 1471mNV 230001m 1641m/W 210001m 1501m/W 4 70 200001m 1471mNV 230001m 1641m/W 210001m 1501m/W 5 70 210001m 1501m/W 235001m 1681m/W 215001m 1541m/W 80% 120W 2 70 180001m 1501mNV 200001m 1671mNV 185001m 1541mNV 3 70 180001m 1501m/W 200001m 1671m/W 185001m 1541m/W 4 70 180001m 1501mNV 200001m 1671m/W 185001m 1541m/W 5 70 185001m 1541mNV 205001m 1711m/W 190001m 1581m/W 2 70 138001m 1531mNV 152001m 1691mNV 142001m 1581m/W 60% 90W 3 70 138001m 1531m/W 152001m 1691m/W 142001m 1581m/W 4 70 138001m 1531m/W 152001m 1691m/W 142001m 1581m/W 5 70 140001m 1561m/W 156001m 1721m/W 145001m 1611m/W 2 70 94001m 1571m/W 103001m 1721m/W 97001m 1621m/W 40% 60W 3 70 94001m 1571m/W 103001m 1721m/W 97001m 1621m/W 4 70 94001m 1571m/W 103001m 1721mNV 97001m 1621mNV 5 70 96001m 1601mNV 105001m 1751m/W 100001m 1671m/W CLLAL08180W SETTING SYSTEM WATTS DIST.TYPE CRI 3000K 4000K 5000K LUMENS LPW LUMENS LPW LUMENS LPW 2 70 248001m 1381m/W 270001m 1501m/W 252001m 1401m/W 100% 180W 3 70 248001m 1381mNV 270001m 1501mNV 252001m 1401mNV 4 70 248001m 1381mNV 270001m 1501mNV 252001m 1401m/W 5 70 255001m 1421m/W 280001m 1561m/W 260001m 1441m/W 2 70 202001m 1401m/W 220001m 1531m/W 206001m 1431m/W 80% 144W 3 70 202001m 1401m/W 220001m 1531m/W 206001m 1431m/W 4 70 202001m 1401m/W 220001m 1531m/W 206001m 1431m/W 5 70 208001m 1441m/W 228001m 1581m/W 210001m 1461m/W 2 70 153001m 1421m/W 168001m 1561m/W 157001m 1451m/W 60% 108W 3 70 153001m 1421m/W 168001m 1561m/W 157001m 1451m/W 4 70 153001m 1421m/W 168001m 1561m/W 157001m 1451m/W 5 70 158001m 1461m/W 173001m 1601m/W 162001m 1501m/W 2 70 105001m 1461mNV 115001m 1601mNV 108001m 1501mNV 40% 72W 3 70 105001m 1461mNV 115001m 1601mNV 108001m 1501mNV 4 70 105001m 1461mNV 115001m 1601m/W 108001m 1501mNV 5 70 108001m 1501m/W 118001m 1641m/W 110001m 1531m/W CLLAL0825OW SETTING SYSTEM WATTS DIST.TYPE CRI 3000K 4000K SOOOK LUMENS LPW LUMENS LPW LUMENS LPW 2 70 335001m 1341mNV 370001m 1481mNV 345001m 1381mNV 100% 250W 3 70 335001m 1341mNV 370001m 1481mNV 345001m 1381mNV 4 70 335001m 1341mNV 370001m 1481mNV 345001m 1381mNV 5 70 345001m 1381m/W 380001m 1521m/W 355001m 1421m/W 2 70 275001m 1381mNV 304001m 1521m/W 284001m 1421m/W 80% 20OW 3 70 275001m 1381mNV 304001m 1521mNV 284001m 1421mNV 4 70 275001m 1381mNV 304001m 1521mNV 284001m 1421mNV 5 70 280001m 1401mNV 310001m 1551m/W 288001m 1441m/W 2 70 213001m 1421m/W 232001m 1551m/W 218001m 1451m/W 60% 150W 3 70 213001m 1421mNV 232001m 1551m/W 218001m 1451m/W 4 70 213001m 1421mNV 232001m 1551mNV 218001m 1451mNV 5 70 218001m 1451mNV 238001m 1591mNV 225001m 1501mNV 2 70 145001m 1451mNV 160001m 1601m/W 148001m 1481m/W 40% 100W 3 70 145001m 1451m/W 160001m 1601m/W 148001m 1481m/W 4 70 145001m 1451mNV 160001m 1601m/W 148001m 1481m/W 5 70 150001m 1501mNV 165001m 1651mNV 155001m 1551mNV CLLAL0830OW SETTING SYSTEM WATTS DIST.TYPE CRI 3000K 4000K 5000K LUMENS LPW LUMENS LPW LUMENS LPW 2 70 410001m 1371mNV 450001m 1501mNV 420001m 1401mNV 100% 30OW 3 70 410001m 1371m/W 450001m 1501m/W 420001m 1401m/W 4 70 410001m 1371m/W 450001m 1501m/W 420001m 1401m/W 5 70 425001m 1421m/W 460001m 1531m/W 435001m 1451m/W 2 70 336001m 1401mNV 370001m 1541mNV 345001m 1441mNV 80% 240VV 3 70 336001m 1401m/W 370001m 1541m/W 345001m 1441m/W 4 70 336001m 1401m/W 370001m 1541m/W 345001m 1441m/W 5 70 345001m 1441m/W 380001m 1581m/W 355001m 1481m/W 2 70 260001m 1441m/W 286001m 1591m/W 266001m 1481m/W 60% 180W 3 70 260001m 1441m/W 286001m 1591m/W 266001m 1481m/W 4 70 260001m 1441m/W 286001m 1591m/W 266001m 1481m/W 5 70 266001m 1481m/W 297001m 1651m/W 275001m 1531m/W 2 70 180001m 1501m/W 200001m 1671m/W 185001m 1541m/W 40% 120W 3 70 180001m 1501mNV 200001m 1671mNV 185001m 1541m/W 4 70 180001m 1501mNV 200001m 1671mNV 185001m 1541mAV 5 70 185001m 1541m/VV 208001m 1731m/W 190001m 1581m/W CLLAL0840OW SETTING SYSTEM WATTS DIST.TYPE CRI 4000K 5000K LUMENS LPW LUMENS LPW LV1 40OW 2 70 605001m 1511m/W 600001m 1501m/W 70 605001m 1511m/W 600001m 1501mNV 4 70 605001m 1511m/W 600001m 1501m/W 5 70 610001m 1531m/W 608001m 1521m/W LV2 360W 2 70 560001m 1561m/W 550001m 1531m/W 3 70 560001m 1561m/W 550001m 1531m/W 4 70 560001m 1561m/W 550001m 1531m/W 5 70 565001m 1571m/W 555001m 1541m/W LV3 320W 2 70 510001m 1591m/W 500001m 1561m/W 3 70 510001m 1591mNV 500001m 1561m/W 4 70 510001m 1591m/W 500001m 1561m/W 5 70 515001m 1611m/W 505001m 1591m/W LV4 300W 2 70 470001m 1621m/W 460001m 1591m/W 70 470001m 1621m/W 460001m 1591m/W 4 70 470001m 1621mNV 460001m 1591mNV 5 70 475001m 1641mNV 465001m 1601m/W BUG @5000K I Mk 100W 120-277W347-480V 2 3 0 3 3 3 0 3 4 3 0 2 5 4 0 2 140W 120-277V/347-480V 2 3 0 3 3 3 0 3 4 3 0 3 5 4 0 2 180W 120-277V/347-480V 2 4 0 3 3 3 0 3 4 3 0 3 5 4 0 2 25OW 120-277V/347-480V 2 4 0 4 3 4 0 4 4 4 0 3 5 5 0 3 30OW 120-277V/347-480V 2 5 0 4 3 4 0 4 4 4 0 4 5 5 0 4 40OW 120-277W347-480V 2 5 0 4 3 5 0 5 4 5 0 5 5 5 0 4 ELECTRICAL DATA 1 850 100 120 0.83 100 208 0.48 100 240 0.42 100 277 0.36 2520 100 347 0.29 100 480 0.21 1200 140 120 1.17 140 208 0.67 140 240 0.58 140 277 0.51 140 347 0.40 140 480 0.29 960 180 120 1.50 180 208 0.87 180 240 0.75 180 277 0.65 180 347 0.52 180 480 0.38 1200 250 120 2.08 250 208 1.20 250 240 1.04 250 277 0.90 250 347 0.72 250 480 0.52 1500 300 120 2.50 300 208 1.44 300 240 1.25 300 277 1.08 300 347 0.86 300 480 0.63 1460 400 120 3.33 400 208 1.92 400 240 1.67 400 277 1.44 400 347 1.15 400 480 0.83 MOUNTING • Standard versatile mounting arm accommodates multiple drilling patterns as well as square and round poles •Optional for cast aluminum slipfitter mounting adapter (Compatible with more mounting adaptors such as Tenon, suits for various application) Mounting Options Arm Mount (4" and 5"Square and Round poles) Standard versatile mounting arm is simple to install and can be used with existing poles for retrofit installations. Mounting Dimensions Round pole 5" O.D. Connecting piece 1 a DIMENSION unit: inch/mm Slipfitter Mount An optional cast aluminum mast arm adapter secures fixture head to nominal 2-3/8"O.D. horizontal steel tenon arm. Wall Mount Yoke Mount Adjustable Arm Mount Wall Mount is easyto install for direct Die-cast aluminum trunnion is easily Standard versatile mounting arm is simple wall mounting with 1/2' conduit wiring or adapted to many surfaces and allows to install and can be used with existing standard J-box mounting easy fixture aiming angles. poles for retrofit installations. Square pole Connecting piece Luminaire Drilling Template E m 010.5mm No: O [00.41in] E 014mm N a [00.55in] N NO E 010.5mm [00.41 in] 100W/140W/180W 100W/140W/180W 100W/140W/180W 100W/140W/180W 100W/140W/180W (Adjustable Square Mount) (Slipfitter Mount) (Wall Mount) (Pole Mount) (Yoke Mount) 0 0 0 0 0 o a o 71—Illim.1 mo •�: 0 3 0 .�. o mo .m. o � mo .�. o � 333 oo 33 0$! 3 _ a71 oi'O 0 — O O — 0102mm 331mm [130in.] 60mm [2.36in] Imo-i] 3?Omm 113.Oin.1 13]mm[5391n] 330mm [130in.] Net Wei eM1t Net Weil. j Net WeigM1t . A t00W:1 :261b _ 100W:6.5816 022mm[00.BIin.] 011mm 0043in. NIWeig3nt 110W:10.3116 w 110W: 12.]]Ib a 1-9.1016 tooW 9. ]Ib ^'^' 199W:t0.5 b e180W:129916 199W:9.3116 _016mrr100.55in.18oW0NBOW: 105916 n- — _ , - ry NttWeig6nt E t00W: 9. 61b _W9.]Ib;2;w.emj eow:9.]em 95mm 3.]4in.i mm {5.99InJ 11 40O 1 0O 111 011 40O 1 0O 11O 0O 111 (Adjustable Square Mount) (Slipfitter Mount) (Wall Mount) (Pole Mount) (Yoke Mount) M ICI I 13� ' a� Ph- �0 I O o '� '�� •_ :: 7 .III •.. • !� •.. •_ I� III{ III ,-A ill■ Its�a��� ..13.8311 I.,ldl�a -•,ill ��-- 1�:1 t'J1, fR�ii i�r!1 EPA OF AREA LIGHT Item • 1 2 @90o �II� 2 @120o 2@180o 3 @90o 3 @120o 4 @90o 100W/140W/180W 0.3632 0.6849 0.8861 0.7264 1.0481 1.2078 1.0481 250W/300W/400W 1 0.4758 0.8091 1.059 0.9516 1.2849 1.3923 1.2849 PHOTOMETRICS We offers a complete set of optical systems to meet every site lighting requirement. These systems provide remarkable flexibility in precisely matching light distribution patterns to specific site requirements. Type 2 optics are ideal for applications where there is Type 3 optics produce an asymmetrical pattern that Type 4 is suitable for applications where light is Type 5 optics produce a symmetrical square distribution a need to space the luminaires farther apart along a directs the majority of the light forward and equally primarily required forward with minimal backlight. pattern that distributes light equally on all sides of the road or pathway. The light distribution pattern is on both sides of the luminaire. In a back-to-back Typical installations include perimeter poles. inaire. Type 5luminaires is universal for most area optimized for elongated areas, allowing for greater configuration, it creates a rectangular pattern which lighlumting applications pole spacing without sacrificing lighting quality. can extend pole spacings. 0 0 o O Type 2 Type 3 Type 4 Type 5 GUIDE Example:ORDERING CLLAL08 Fixture Wattage Voltage OCT Finish Photocell Sensor Mounting Photometry CCT and Power Internal Code Type (Option) (Option) Adjustable CLLAL08 100 10OW 27V 120-277V DDK' D Dark Bronze PO 120-277V Photocell M With Sensor Sn Square Pole Mount T2 TYPE II AD' Blank Area Light Series 140 140W 48V 347-480V wlo stable B Black P3 347V Photocell Blank Without Sensor SP Slipfitter Mount T3 TYPE III With adjustment dial Alphanumeric 180 180W temperature W White P4 480V Photocell WM Wall Mount T4 TYPE IV Blank 250 25OW SG Silver Gray Blank Without Photocell YK Yoke Mount T5 TYPEV Without adjustment dial 300 30OW SOA Adjustable 400 40OW Square Mount Note: Only 40OW suit for 4000K, 5000K adjustable and other wattage suit for 3000K, 4000K and 5000K andjustable. ACCESSORIES(Optional) CLLAL08 series features a backlight control which provides reduced pixilation and increased visual comfort without compromising performance. External Glare Shield: sold separately or as an accessory. Plug -and -Play PIR Sensor PIR sensor: ANT-6-4T Bluetooth PIR sensor: ANT-6-4T-BLE-SR NEMA Photocell 3 pin NEMA Type: MS-PSUNVBI 3 pin NEMA Type(480V): JL-207F 7 pin NEMA Type: JL-241C ADDITIONAL MOUNTING ACCESSORIES 60mm(2 3/8u.) 4" Round Pole Mount with 2-3/8" O.D. Tenon 60mm(2 3)8in_) 4" Square Pole Mount with 2-3/8" O.D. Tenon No.45Q-SP-D NO.4SQR-SP-D 3 Finish: Dark Bronze USE: For use with square, non.tapered steel and aluminum poles. 3 Finish:Dark Bronze USE: For use with Round, non -tapered steel and aluminum poles. Furnished with four 5/16" hex head stainless -steel bolts. Vertical - Furnished with three 3/8' hex head stainless -steel bolts. Vertical E_ tenon measures 2-3/8' O.D., and is made of steel tubing. Fixtures ounted to this bracket can be adjusted both venically and 3 _ a tenon measures 2-3/8" O.D., and is made of steel tubing. FiMures mounted to this bracket on be adjusted both vertically horizontally. ,_ 106.68—R.2in ) and horizontally. 60mm(2 3/8in.) 5" Square Pole Mount with 2-3/8" O.D. Tenon 60mm(2 3/8in.) 5" Round Pole Mount with 2-3/8" O.D. Tenon c. No. SSQ-SP-D N0.5SQR-SP-D Finish: Dark Bronze Finish:Da k Bronze 3 USE: For use with square, non -tapered steel and aluminum poles. 3 USE: For use with Round, non -tapered steel and aluminum poles. Furnished with four 5/16" hex head stainless -steel bolts. Vertical m Furnished with three 3/8' hex head stainless -steel bolts. Vertical E _ E tenon measures 2-3/8' O.D., and Is made of steel tubing. Fixtures ounted to this bracket on be adjusted both vertically and 3 _ 3 tenon measures 2-3/8" O.D., and is made of steel tubing. Fixtures mounted to this bracket on be adjusted both vertically ^ lSinj ro horizontally. " 131.86anan gin) and horizoni 5±1mm(608 in) 154r Pole Bracket Accessories -Angle -Adjustment Adapter NO. SQA-ALDA -NO. Pole Bracket cessories-Tenon &Yoke Adaptor ac SP-TR-D Finish: Dark Bronze Finish: Dark Bronze USE: Durable brackets areengineered to crevice versatileEUSE: The 2-3/8" OD Tenon Mount Adaptor for Yoke Fixtures is ountIng options. These arms are made from rugged diecast designed to mount light fixtures that are equipped with a yoke aluminum. They allow optimal positioning of the light fixture to ount onto a 2-3/8" OD tenon. It may be utilized with the Flood maximize the lighting effectiveness vertically and honzontally. Light Series of light fixtures. 63mm(2.48in) Hwimntal Wall or Square or Round pole mount with 2.3/8" Tenon Brackat NO. SO/R-SP-D Finish: Dark Bronze to USE: This tenon bracket wn be installed ona wall, square pole. round pole. Provides wiring aaess and abuilt-in 2-3/8" O.D. tenon to mount a fixture witP our adjustable slipfitter. Suggested 3/8' diameter bolts for mounting. Attache, to any flat WALL BRACKET Provides wiring access 60mm (2 Yon) ... face 90" Wall Mount Bracket With 2.3/8" O.D. Tenon NO. W M-SP-D Mid -Pole tenon Bracket 1s5mm7.29in) 23/8" OD Had zontal Tenon Midi Bracket - Finish: Dark Bronze 'g NO. SO-SP-D USE: The 90'wa11 mount bracketwith 2-3/8" tenon attaches an 3 Finish:Da k Bronze floodlight to almost any surface: wall, roof, or wood pole. Provides g USE:2-3/8" OD Horizontal Tenon Mid -Pole Bracket is designed 3 firing access and abuilt-in 2-3/8" O.D. tenon to mount a fixture wsllpfitter. Suggested 3/8' diameter bolts for ith our adjustable - a - to mount light fixture that is equipped with a adjustable slipfitter onto a 2-3/8" OD horzomal ..on -- 22].2mmp.]6 m .) Round External Mount Horizontal mounting. Mounting holes era spaced 3-1 A' apart. Tenon - To mount 2/3/4 fixtures on a existing pole n�o1 Double 90' Horizontal Tenon Adaptor NO. R60-SP2-90-D mm(ainl @ _ Triple 12W Horizontal Tenon Adaptor NO. R60-SP3-120-D Finish:Dark Bronze Finish:Da k Bronze - e USE:The Bracket is designed to mount over 2-3/8" (60mm) O.D. - USE:The Bracket is designed to mount over 2-3/8" (60mm) O.D. - vertical tenon. Two fixtures can be mounted to the Round Fxtamal - vertical tenon. Three fixtures can be mounted to the Round External Mount Horizontal Tenon and adjusted horizontally Mount Horizontal Tenon and adjusted horizontally 6asmmR.sin 1 63smmR.sln 1 Double 180' Horizontal Tenon Adaptor \ Quad 90' Horizontal Tenon Adaptor NO. R60-SP2-180-D g NO. R60-SP4-90-D Finish:Dark Bronze Finish:Da k Bronze USE:The Bracket is designed to mount over 2-3/8" (60mm) O.D. %USE:The Bracket is designed to mount over 2-3/8" (60mm) 0.D. _ vertical tenon. Two fixtures can be mounted to the Round External vertical tenon. Four I—, can be mounted to the Round atemal Mount Horizontal Tenon and adjusted horizontally S Mount Horizontal Tenon and adjusted horizontally 63...Q,1n.) 63.SmmRSinJ _ totem Triple 90' Horizontal Tarwn Adaptor NO. R60-SP3-90-D = Finish:Dark Bronze USE:Th, Bracket is designed to mount over 2-3/8" (60mm) O.D. - vertical tenon. Three fixtures can be mounted to the Round External 635mm(25in) Mount Horizontal Tenon and adjusted horizontally Specifications are subject to change without notice. Updated date: 2023-08-31 Statement of Operations This is the application for the installation of 4 -18' light poles with 4 shielded LED light fixtures to illuminate a sport court in the backyard of my residence. The sport court will be intended for basketball and pickleball. The lights and light poles will be bronze in color. The light fixture will have a polycarbonate lens that is intended to minimize the spread of light beyond the court area. The court will be surfaced with a non -reflective coating commonly used on tennis/sport courts. The lights will be no closer than 30' from the nearest property line and we are planning to install a ficus hedge along the length of that property line that will significantly block any view of the light fixtures. Furthermore, the court will be surrounded by the planting of mature oak and olive trees that will further mitigate any potential effects. The remaining property lines are at least 60' away from the light fixtures. The court is expected to get infrequent use and will not be used between 10PM and sunrise. There will be no employees or additional local, state or federal permits required beyond the MUP from the city of La Quinta. Other than nets and paddles, no other equipment is required. No hazardous material will be used or stored. Property Photographs View facing west. View of area where the sport court will be located. The excavated area is approximately 10' larger in each dimension than the actual finished court area. Aerial view of the overall location of the property. Pin marks the vacant lot. Architectural Site Plan - sport court at west side of property A D(-UITIZY-TI ID A l Planting plan around the sport court. Ultimately, the ficus hedge will mirror the existing hedges on the north side of the property — see photos le' TAUin=$ MWai -- -- _ -- - � M M SC M SC SC SC 5CM SCE - SC ._ SCE � sc M era • M1, 5C1 • C. DC TEE SC M • ® a.. cc SC era 1 C O . DC Vl C lM Ole ( l 2' DG l SC M � M M i N M M J d4lf �I SC c I M SCE C� SPA 4 5C V on HAs1{E•pSALL t Q • 'I .4 ® 5c 2 9 fC1 z l ,r SCM : ! M F!c! BALL i ueW g % sc sa naa �' M u SC yi SC 9PA DG. f M +� . 4 !' n i❑ SC 2 �. SC i. SCE C� M M N � � S 5C M FcJ sc M + M M M C Call e Coll • sc`.r s' r G `.� PUMNG GREEN d _ ameusl y� M SC O • Mmurra j` 1�` G1 s• r ' Without Shields With Shields 10/22/2025 Light Trespass with Glare Shields @ 100% Power _� c� COMMERCIAL OAlt &VrrjorcoNwvrnafyuaUn lighting Footcandle Scale There are existing CMU block walls at the western and southern property lines that are approximately 5' tall. The light trespass drops to virtually zero at these locations due to the height of the walls.