BTCP2016-0001 Title 24 RevisionsTitle 24 Energy Report
RFo�siou S L5
a
The Haciendas at PGA W
La Quinta
gt
13 J i:'.- D 1 N t`;4 & S . AFETY DEPT.
MR COi%4qT'RLJ'CCTI0,I-q
12013 Buildiniz Enemy Efficiency Standards{
BEG Project No.: 14024
Revised Report: Delta 3
California West Construction
Heritage Energy Group, LLC
February 3, 2016
Tel: (949) 789-7221 / Fax: (949) 789-7222
9 20"10"
C FTy?
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1 U.xml
CF1 R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
Plan 1 - Haciendas
02
Calculation Description
Title 24 Analysis
03
Project Location
_ •
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-2 (595c)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
1941
15
Number of Zones
1
16
Slab Area (FT2)
1941
17
Number of Stories
1
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
NA
21
Glazing Percentage (%)
24.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verzification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
This Certificate of Compliance is for permit applications made BEFORE October 13, 2014
Registration Number: 216-N0043901A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CeRTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time. 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1 U.xml
CF1 R-PRF-01
Page 2 of 8
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.70
2.15
-0.45
-26.5%
Space Cooling
114.54
115.88
-1.34
-1.2%
IAQ Ventilation
1.31
1.31
0.00
0.0%
Water Heating
13.44
6.49
6.95
51.7%
PV Credit
----
0.00
0.00
---
North Facing - TOTAL
130.99
125.83
5.16
3.9%
Space Heating
1.70
2.34
-0.64
-37.6%
Space Cooling
114.54
110.41
4.13
3.6%
IAQ Ventilation
1.31
1.31
0.00
0.0%
Water Heating
13.44
6.49
6.95
51.7%
PV Credit
----
0.00
0.00
---
East Facing - TOTAL
130.99
120.55
10.44
8.0%
Space Heating
1.70
2.50
-0.80
-47.1%
Space Cooling
114.54
'M F
115.30 „l`a
�'
-0.76
0.00
-0.7%
0.0%
IAQ Ventilation
1.31
1.31 ,
r
'
51.7%
Water Heating
13.44
6.49
k
6.95
PV Credit
t
'~
0.00 �'-
0.00
- --
South Facing - TOTAL
130.99
125.60
5.39
4.1%
Space Heating
1.70
1.77
-0.07
-4.1%
Space Cooling
114.54
107.62
6.92
6.0%
IAQ Ventilation
1.31
1.31
0.00
0.0%
Water Heating
13.44
6.49
6.95
51.7%
PV Credit
-
0.00
0.00
--
West Facing -TOTAL
130.99
117.19
13.80
10.5%
Registration Number: 216-N0043901A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016 Page 3 of 8
Calculation Description: Title 24 Analysis Input File Name: 14024P1U.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Non-standard roof reflectance
• Window overhangs and/or fins
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 1- Haciendas
1941
1
4
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System
Zone Floor Area
(ft2)
Avg. Ceiling
Height `�1'
Water Heating System 1
Water Heating System 2
Zone 1
Conditioned
HVAC System1
1941
10
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
Front Wall
Zone 1
R-19 Wall
0
Front
222
15
90
Left Wall
Zone 1
R-19 Wall
90
Left
606
112
90
Rear Wall
Zone 1
R-19 Wall
180
Back
369
210.5
90
Right Wall
Zone 1
R-19 Wall
270
Right
808
128
90
garage wall
Zone 1
R-19 Wall NSG
0
Front
300
0
90
Roof
Zone 1
R-38 Roof Attic RB
1941
Registration Number: 216-N0043901A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1 U.XmI
CF1 R-PRF-01
Page 4 of 8
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
5
0.1
0.85
Yes
No
NINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multipli
er
Area (ft2)
U-
factor
SHG
C
Exterior Shading
3050
Window
Front Wall (Front-0)
---
-
1
15.0
0.29
0.20
3080
Window
Left Wall (Left-90)
---
---
1
24.0
0.35
0.25
4050-2
Window
Left Wall (Left-90)
---
-
1
40.0
0.29
0.20
4020=2
Window
Left Wall (Left-90)
---
-
1
16.0
0.27
0.20
3040
Window
Left Wall (Left-90)
-
- -
1
12.0
0.29
0.20
4050
Window
Left Wall (Left-90)
--
-
1
20.0
0.27
0.20
3050-3
Window
Rear Wall (Back-180)
----
--
1
45.0
0.29
0.20
3016-3
Window
Rear Wall (Back-180)
--
--
1
13.5
0.27
0.20
16080 dr
Window
Rear Wall (Back-180)
16.0
8.0
1
128.0
0.28
0.21
3020-4
Window
Rear Wall LBack-180)
--
---
1
24.0
0.29
0.20
3050-2
Window
Right Wall (Right-270)
--
--
1
30.0
0.29
0.20
3016-2
Window
Right Wall (Right-270)
--
-
1
9.0
0.27
0.20
40502 p
Window
Right Wall (Right-270)
----
----
1
20.0
0.29
0.20
2040
Window
Right Wall (Right-270)
--
--
1
8.0
0.29
0.20
5050
Window
Right Wall (Right-270)
--
---
1
25.0
0.29
0.20
IZZ
5020
Window
Right Wall (Right-270)
--
---
1
10.0
0.27
0.20
2030
Window
Right Wall (Right-270)
-
- --
1
6.0
0.29
0.20
2050-2
Window
Right Wall (Right-270)
---
-
1
20.0
0.29
0.20
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
Right Wall
28.0
0.50
Registration Number: 216-N0043901A-000000000-0000 Registration Date/Time: 2016-02-0309:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1 U.xml
CF1 R-PRF-01
Page 5 of 8
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
16080 dr
11
0.1
1
20
1
0
0
0
0
1 0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
Roofing: 10 PSF (RoofTile)
Above Deck Insulation - no insulation -
2x4 Top Chord of
Roof Deck. Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Cavity. - no insulation -
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
Inside Finish: - select inside finish -
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathinglnsul. -
Cavity. R 19
Sheathing/Insulation: - no sheathing/insul. -
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
Attic Floor: - no attic floor -
Cavity: R 38
Sheathinglnsulation - no sheathing/insul. -
R-38 Roof Attic RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Inside Finish: Gypsum Board
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity. R 19
Sheathing/Insulation: - no sheathing/insul. -
R-19 Wall NSG
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Slab
Zone 1
1941
229
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation(QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Not Required
--
Registration Number: 216-NO0439OIA-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Input File Name: 14024P1 U.xml
C F1 R-P RF-01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
DHW Sys 1
Standard
1
0.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.95
185000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a
n/a
n/a
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC System1
Other Heating and Cooling System
Heating Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan 1
1941
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03
04
05
Name
System Type
Efficiency
EER SEER
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning system
11.7
14
Cooling Component 1-hers-cool
Registration Number: 216-NO043901A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1U.xml
CF1 R-PRF-01
Page 7 of 8
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
HVAC Systeml SCSysRpt 1
Required
350
—
14.0
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
y
Ducts located in unconditioned
Sealed and tested
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
attic
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
Name
Duct Leakage Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
Required
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
Name
IAQ CFM
IAQ Fan Type
IAQ Recovery Effectiveness(%)
HERS Verification
IAQ Fan
57
Exhaust
0
Required
Registration Number: 216-N0043901A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 1 - Haciendas Calculation Date/Time: 11:08, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P1 U.xml
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
Company:
Signature Date:
Heritage Energy Group
2016-02-03 09:08:19
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949-584-1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
ResponsibleDesigner Signature:
Pi�a�r�
VW
Dave Warren
Company:
Date Signed: t R
California West Communities
2016-02-03 09:12:45 �''a
Address:
License:
5927 Priestly Drive, Suite 103
N/A
City/State/Zip:
Phone:
Carlsbad, CA 92008
760-918-2824
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-NO0439OIA-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:13:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01
Project Name
Plan 2 - Haciendas
02
Calculation Description
Title 24 Analysis
03
Project Location
_
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-2 (595c)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2042
15
Number of Zones
1
16
Slab Area (FT2)
2042
17
Number of Stories
1
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
rF7
Addition Slab Area (FT2)
NA
21
Glazing Percentage (%)
26.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
This Certificate of Compliance is for permit applications made BEFORE October 13, 2014
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 2 of 8
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
1.56
2.07
-0.51
-32.7%
Space Cooling
112.53
116.11
-3.58
-3.2%
IAQ Ventilation
1.10
1.10
0.00
0.0%
Water Heating
12.96
6.34
6.62
51.1%
PV Credit
---
0.00
0.00
---
North Facing - TOTAL
128.15
125.62
2.53
2.0%
Space Heating
1.56
2.60
-1.04
-66.7%
Space Cooling
112.53
108.37
4.16
3.7%
IAQ Ventilation
1.10
1.10
0.00
0.0%
Water Heating
12.96
6.34
6.62
51.1%
PV Credit
----
0.00
0.00
---
East Facing - TOTAL
128.15
118.41
9.74
7.6%
Space Heating
1.56
2.35
-0.79
-50.6%
Space Cooling
IAQ Ventilation
112.53
1.10C�
y
VMM
ft
114.00
1.10
;8
-1.47
0.00
-1.3%
0.0%
Water Heating
12.96
�"
r r ,
.
634 w:n..
6.62
51.1%
PV Credit
----
t_
0.00;
0.00
----
South Facing -TOTAL
128.15
123.79
4.36
3.4%
Space Heating
1.56
1.58
-0.02
-1.3%
Space Cooling
112.53
107.89
4.64
4.1%
IAQ Ventilation
1.10
1.10
0.00
0.0%
Water Heating
12.96
6.34
6.62
51.1%
PV Credit
---
0.00
0.00
---
West Facing - TOTAL
128.15
116.91
11.24
8.8%
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01
Project Name: Plan 2 - Haciendas Calculation Date/Time: 11:17, Tue, Feb 02, 2016 Page 3 of 8
Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Non-standard roof reflectance
• Window overhangs and/or fins
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 2- Haciendas
2042
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Zone 1
Conditioned
HVAC System1
2042
10:1
DHW Sys 1
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
Front Wall
Zone 1
R-19 Wall
0
Front
182
44
90
Left Wall
Zone 1
R-19 Wall
90
Left
525
141
90
Rear Wall
Zone 1
R-19 Wall
180
Back
354
180
90
Right Wall
Zone 1
R-19 Wall
270
Right
848
181.5
90
garage wall
Zone 1
R-19 Wall
0
Front
210
0
90
garage wall2
Zone 1
R-19 Wall
90
Left
320
0
90
Roof
Zone 1
R-38 Roof Attic RB
2042
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 4 of 8
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
5
0.1
0.85
Yes
No
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multipli
er
Area (ft2)
U-
factor
SHG
C
Exterior Shading
2060-3
Window
Front Wall (Front-0)
---
---
1
36.0
0.29
0.20
2020-2
Window
Front Wall (Front-0)
---
---
1
8.0
0.27
0.20
12080
Window
Left Wall (Left-90)
12.0
8.0
1
96.0
0.28
0.21
2050-2
Window
Left Wall (Left-90)
5.0
5.0
0.8
20.0
0.29
0.20
5050
Window
Left Wall (Left-90)
-
---
1
25.0
0.29
0.20
3060-2
Window
Rear Wall (Back-180)
--
-
1
36.0
0.29
0.20
6060/6030/3030-2
Window
Rear Wall (Back-180)
3.0
3.0
8
72.0
0.27
0.20
9080
Window
Rear Wall (Back-180)
9.0
8.01
72.0
0.28
0.21
3060-4
Window
Right Wall (Right-270)
----
--
1
72.0
0.29
0.20
.74 3030-2
Window
Right Wall (Right-270)
--
- -
1
Y
18.0
0.27
0.20
3060-2 2
Window
Right Wall (Right-270)
-
-- -
1
36.0
0.29
0.20
50502
Window
Right Wall (Right-270)
---
--
1
25.0
0.29
0.20
5020
Window
Right Wall (Right-270)
----
---
1
10.0
U.
0.20
2040
Window
Right Wall (Right-270)
---
-
1
8.0
0.29
0.20
2650
Window
Right Wall (Right-270)
--
--
1
12.5
0.29
0.20
DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
Right Wall
28.0
0.50
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 5 of 8
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
12080
12
1
12
10
1
0
0
0
0
0
0
0
0
2050-2
2
2
2
2
0
0
0
0
0
0
0
0
0
6060/6030/3030-2
2
2
2
2
0
0
0
0
0
0
0
0
0
9080
12
1
12
10
1
0
0
1 0
1 0
0
0
1 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
Roofing: 10 PSF (RoofTile)
Above Deck Insulation - no insulation -
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Cavity. - no insulation -
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
Inside Finish: - select inside finish -
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity: R 19
e.
Sheathing/Insulation: - no sheathing/insul. -
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
Attic Floor. - no attic floor -
Cavity. R 38
Sheathinglnsulation - no sheathing/insul. -
R-38 Roof Attic RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Inside Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Slab
Zone 1
2042
220
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation(QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Not Required
---
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
DHW Sys 1
Standard
1
0.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.95
185000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a
n/a
n/a
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC System1
Other Heating and Cooling System
Heating Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan 1
2042
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03
04
05
Name
System Type
Efficiency
EER SEER
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning system
11.7
14
Cooling Component 1-hers-cool
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Input File Name: 14024p2U.xml
CF1 R-PRF-01
Page 7 of 8
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
HVAC System1 SCSysRpt 1
Required
350
---
14.0
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in unconditioned
Sealed and tested
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
attic
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
Name
Duct Leakage Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
Required
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
Name
IAQ CFM
IAQ Fan Type
IAQ Recovery Effectiveness(%)
HERS Verification
IAQ Fan
50
Exhaust
0
Required
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 2 - Haciendas
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:17, Tue, Feb 02, 2016
Input File Name: 14024p2U.xml
CFI R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
Company:
Signature Date:
Heritage Energy Group
2016-02-03 09:08:19
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949-584-1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
ResponsibleDesigner Signature: W�i,
�lu/Pil�/A�TI�.sli
Dave Warren
Company:
Date Signed:
California West Communities
2016-02-03 09:12:45
Address:
License:
5927 Priestly Drive, Suite 103
N/A
City/State/Zip:
Phone:
Carlsbad, CA 92008
760-918-2824
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-N0043909A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:22:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3 Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P3U.xml
CFI R-PRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Plan 3
02
Calculation Description
Title 24 Analysis
03
Project Location
_
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-2 (595c)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2423
15
Number of Zones
1
16
Slab Area (FT2)
1941
17
Number of Stories
2
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
NA
21
Glazing Percentage (%)
24.3%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
This Certificate of Compliance is for permit applications made BEFORE October 13, 2014
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Input File Name: 14024P3U.xml
CF1 R-PRF-01
Page 2 of 10
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
3.32
4.18
-0.86
-25 9%
Space Cooling
119.48
117.42
2.06
1.7%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.54
5.90
5.64
48.9%
PV Credit
---
0.00
0.00
---
North Facing -TOTAL
135.34
128.50
6.84
5.1%
Space Heating
3.32
3.96
-0.64
-19.3%
Space Cooling
119.48
117.42
2.06
1.7%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.54
5.90
5.64
48.9%
PV Credit
---
0.00
0.00
-
East Facing - TOTAL
135.34
128.28
7.06
5.2%
Space Heating
3.32
3.84
-0.52
-15.7%
Space Cooling
IAQ Ventilation
119.48
1.00
Aowu Www 118.64
1.00
4
0.84
0.00
0.7%
0.0%
Water Heating
11.54
r 5.90
f tt
5.64
48.9%
PV Credit
----
,-- r- R S P0.00
'
0.00
--
South Facing - TOTAL
135.34
129.38
5.96
4.4%
Space Heating
3.32
3.81
-0.49
-14.8%
Space Cooling
119.48
116.83
2.65
2.2%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.54
5.90
5.64
48.9%
PV Credit
--
0.00
0.00
---
West Facing - TOTAL
135.34
127.54
7.80
5.8%
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Input File Name: 14024P3U.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Non-standard roof reflectance
• Window overhangs and/or fins
CF1 R-PRF-01
Page 3of10
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 3
2423
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Zone 1
Conditioned
HVAC System1
2423
10
DHW Sys 1
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3 Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P3U.xml
CF1 R-PRF-01
Page 4of10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft)
Tilt(deg)
Front Wall
Zone 1
R-19 Wall
0
Front
364
114
90
Left Wall
Zone 1
R-19 Wall
90
Left
586
7.992
90
Rear Wall
Zone 1
R-19 Wall
180
Back
364
36
90
Right Wall
Zone 1
R-19 Wall
270
Right
283
21
90
Front Wall 2
Zone 1
R-19 Wall
0
Front
182
15
90
Left Wall 2
Zone 1
R-19 Wall
90
Left
586
112.012
90
Rear Wall 2
Zone 1
R-19 Wall
180
Back
374
186.5
90
Right Wall 2
Zone 1
R-19 Wall
270
Right
808
97
90
garage wall
Zone 1
R-19 Wall
0
Front
300
0
90
garage wall2
Zone 1
R-19 Wall
90
Left
200
0
90
Roof
Zone 1
R-38 Roof Attic RB
482
Roof 2
Zone 1
R-38 Roof Attic RB
2036
Right garage wall
Garage
Garage E)&Wall
270
Right
333
0
90
Front garage wall
Garage
Garage Ext Wall
0
Front
333
0
90
Left garage wall
Garage
Garage Ext Wall
270
Right
333
0
90
Exterior Wall
Garage
Garage Ext Wall
0
Front
1
0
90
Roof 3
Garage
Garage Roof
502
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
5
0.1
0.85
Yes
No
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
I
I
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3 Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P3U.xml
CF1 R-PRF-01
Page 5 of 10
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multipli
er
Area (ft2)
U-
factor
SHG
C
Exterior Shading
2030-3
Window
Front Wall (Front-0)
--
- -
1
18.0
0.29
0.20
12080
Window
Front Wall (Front-0)
-- -
-
1
96.0
0.28
0.21
2040
Window
Left Wall (Left-90)
6.0
6.0
0.222
8.0
0.29
0.20
2030-6
Window
Rear Wall (Back-180)
---
---
1
36.0
0.29
0.20
3070
Window
Right Wall (Right-270)
---
---
1
21.0
0.29
0.20
3050
Window
Front Wall 2 (Front-0)
----
----
1
15.0
0.29
0.20
3080 frdr
Window
Left Wail 2 (Left-90)
6.0
6.0
0.667
24.0
0.35
0.25
4050-2
Window
Left Wall 2 (Left-90)
5.0
5.0
1.6
40.0
0.29
0.20
4020-2
Window
Left Wall 2 (Left-90)
-
-
1
16.0
0.29
0.20
3040
Window
Left Wall 2 (Left-90)
-
-
1
12.0
0.29
0.20
4050
Window
Left Wall 2 (Left-90)
-
-
1
20.0
0.29
0.20
3050-3
Window
Rear Wall 2 (Back-180)
-
c -
1
45.0
0.29
0.20
3016-3
Window
Rear Wall 2 (Back-180)
3.0
;3;0
1.5
13.5
0.29
0.20
16080 ddr
Window
Rear Wall 2 (Back-180)
8.0
8.0
2r,_
128.0
0.28
0.21
3050-2
Window
Right Wall 2 (Right-270)
-- F
-
1
30.0
0.29
0.20
3016-2
Window
Right Wall 2 (Right-270)
---
-
1
9.0
0.29
0.20
4060
Window
Right Wall 2 (Right-270)
-
--
1
24.0
0.29
0.20
20402
Window
Right Wall 2 (Right-270)
----
--
1
8.0
0.29
0.20
2060
Window
Right Wall 2 (Right-270)
---
--
1
6.0
0.29
0.20
2050-2
Window
Right Wall 2 (Right-270)
- -
- -
1
20.0
0.29
0.20
DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
Door
Right Wall 2
28.0
0.50
Door 16080
Front garage wall
128.0
1.00
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-0309:12:45
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c
HERS Provider: CaICERTS inc.
Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3 Calculation DatelTime: 11:33, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P3U.xml
CFI R-PRF-01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
2040
12
1
10
10
0
0
0
0
0
0
0
0
0
3080 frdr
12
1
10
10
0
0
0
0
0
0
0
0
0
4050-2
2
2
2
2
0
0
0
0
0
0
0
0
0
3016-3
2
2
2
2
0
0
0
0
0
0
0
0
0
16080 ddr
12
1
10
10
0
0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
Roofing: 10 PSF (RoofTile)
Above Deck Insulation - no insulation -
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Cavity. - no insulation -
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
Inside Finish: - select inside finish -
Attic Floor. - no attic floor -
Cavity. - no insulation -
Sheathinglnsulation - no sheathing/insul. -
Garage Roof
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
inside Finish: Gypsum Board
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity: R 19
Sheathing/Insulation: - no sheathing/insul. -
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
Attic Floor: - no attic floor -
Cavity. R 38
Sheathinglnsulation - no sheathing/insul. -
R-38 Roof Attic RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Inside Finish: Gypsum Board
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity. - no insulation (vertical) -
- no insulation
Sheathing/Insulation: - no sheathing/insul. -
Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
(vertical) -
Exterior Finish: 3 Coat Stucco
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Input File Name: 14024P3U.xml
CFI R-PRF-01
Page 7 of 10
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Slab
Zone 1
1941
223
None
0.8
No
Slab 2
Garage
502
90
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation(Qll)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Not Required
---
WATER HEATING SYSTEMS
01
02
03
04
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
DHW Sys 1
Standard
1
0.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.95
185000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a
n/a
n/a
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC Systeml
Other Heating and Cooling System
Heating Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System I
HVAC Fan 1
2423
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3 Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P3U.xml
CF1 R-PRF-01
Page 8 of 10
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING SYSTEMS
01
02
03
04
05
Name
System Type
Efficiency
EER SEER
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning system
11.7
14
Cooling Component 1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
HVAC Systeml SCSysRpt 1
Required
350
---
14.0
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution
Air Distribution System 1
Ducts located in unconditioned
Sealed and tested
6
Attic
Attic
None
System 1-hers-dist
attic
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
Name
Duct Leakage Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
Required
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Input File Name: 14024P3U.xml
CF1 R-PRF-01
Page 9 of 10
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
Name
IAQ CFM
IAQ Fan Type
IAQ Recovery Effectiveness(%)
HERS Verification
IAQ Fan
54
Exhaust
0
Required
Registration Number: 216-N0043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 3
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:33, Tue, Feb 02, 2016
Input File Name: 14024P3U.xml
CFI R-PRF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
%�" �✓�aGsca
Rudy Sains
Company:
Signature Date:
Heritage Energy Group
2016-02-03 09:08:19
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949-584-1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
ResponsibleDesigner Signature:
Dave Warren
Company: 9
— w R
Date Signed:
x
California West Communities
2016-02-03 09:12:45
Address:
License:
5927 Priestly Drive, Suite 103
N/A
City/State/Zip:
Phone:
Carlsbad, CA 92008
760-918-2824
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-1\10043915A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T11:39:54
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
C F1 R-P RF-01
Page 1 of 11
GENERAL INFORMATION
01
Project Name
Plan 4
02
Calculation Description
Title 24 Analysis
03
Project Location
_
04
A City
La Quinta
05
Standards Version
Compliance 2014
06
Zip code
07
Compliance Manager Version
BEMCmpMgr 2013-2 (595c)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 6.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
Cardinal
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (FT2)
2429
15
Number of Zones
1
16
Slab Area (FT2)
2042
17
Number of Stories
2
18
Addition Cond. Floor Area
NA
19
Natural Gas Available
Yes
20
Addition Slab Area (FT2)
NA
21
Glazing Percentage (%)
23.6%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
This Certificate of Compliance is for permit applications made BEFORE October 13, 2014
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4 Calculation Date/Time; 12:00, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P4U.xml
CFI R-PRF-01
Page 2 of 11
ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
Percent
(kTDV/ft2-yr)
Design
Design
Margin
Improvement
Space Heating
2.26
3.18
-0.92
-40.7%
Space Cooling
110.42
111.91
-1.49
-1.3%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.52
5.90
5.62
48.8%
PV Credit
----
0.00
0.00
--
North Facing -TOTAL
125.20
121.99
3.21
2.6%
Space Heating
2.26
3.49
-1.23
-54.4%
Space Cooling
110.42
107.40
3.02
2.7%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.52
5.90
5.62
48.8%
PV Credit
---
0.00
0.00
---
East Facing - TOTAL
125.20
117.79
7.41
5.9%
Space Heating
2.26
3.30
-1.04
-46.0%
Space Cooling
110.42s
'
111.41
-0.99
-0.9%
IAQ Ventilation
1.00a
1.00
0.00
0.0%
Water Heating
11.52
5.90
5.62
48.8%
PV Credit
----
--
0.00
0.00
----
South Facing -TOTAL
125.20
w«
121.61
3.59
2•9%
Space Heating
2.26
2.80
-0.54
-23.9%
Space Cooling
110.42
106.85
3.57
3.2%
IAQ Ventilation
1.00
1.00
0.00
0.0%
Water Heating
11.52
5.90
5.62
48.8%
PV Credit
----
0.00
0.00
--
West Facing - TOTAL
125.20
116.55
8.65
6.9%
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Non-standard roof reflectance
• Window overhangs and/or fins
CF1 R-PRF-01
Page 3 of 11
PROJECT HERS FEATURES
The following are project -level features that must be field -verified as a condition for meeting the modeled energy performance for this computer analysis. These, plus any additional HERS features listed
in the building components tables below requre field verification by a certified HERS Rater.
Check the individual building component sections below for any required HERS verification requirements.
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (sft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Plan 4
2429
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
living
Conditioned
HVAC System
2429
10.1
DHW Sys 1
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4 Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 4of11
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window Area (ft2)
Tilt(deg)
Front Wall
living
R-19 Wall
0
Front
152
40
90
Left Wall 2x4
living
R-13 Wall
90
Left
343
0
90
Rear Wall
living
R-19 Wall
180
Back
152
12
90
Right Wall
living
R-19 Wall
270
Right
343
49
90
Front Wall 2
living
R-19 Wall
0
Front
172
36
90
Left Wall
living
R-19 Wall
90
Left
505
145.012
90
Rear Wall 2
living
R-19 Wall
180
Back
394
180
90
Right Wall 2
living
R-19 Wall
270
Right
828
110.5
90
garage wall
living
R-19 Wall
0
Front
210
0
90
garage wa112
living
R-19 Wall
90
Left
310
0
90
Roof
living
R-38 Roof Attic RB
387
Roof 2
living
R-38 Roof Attic RB
1652
Interior Surface
living»Garage
R-19 Wall1
10
garage wall right
Garage
Garage Ext Wall
270
Right
172
0
90
garage wall Front
Garage
Garage Ext Wall
0
Front
233
0
90
garage wall Left
Garage
Garage Ext Wall
90
Left
346
0
90
Exterior Wall
Garage
Garage Ext Wall
180
Back
1
0
90
Roof 3
Garage
R-0 Roof Attic
542
ATTIC
01
02
03
04
05
06
07
Name
Construction
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic
Attic Roof Cons
5
0.1
0.85
Yes
No
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
CFI R-PRF-01
Page 5 of 11
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width(ft)
Height
(ft)
Multipli
or
Area (ft2)
U-
factor
SHG
C
Exterior Shading
2680-2 frdr
Window
Front Wall (Front-0)
--
--
1
40.0
0.35
0.25
3040
Window
Rear Wall (Back-180)
-
--
1
12.0
0.29
0.20
3070
Window
Right Wall (Right-270)
--
--
1
21.0
0.29
0.20
2050-2
Window
Right Wall (Right-270)
----
--
1
20.0
0.29
0.20
2040
Window
Right Wail (Right-270)
--
--
1
8.0
0.29
0.20
2060
Window
Front Wall 2 (Front-0)
----
-
1
12.0
0.29
0.20
20602
Window
Front Wall 2 (Front-0)
---
- -
1
12.0
0.29
0.20
20603
Window
Front Wall 2 (Front-0)
---
--
1
12.0
0.29
0.20
12080 ddr
Window
Left Wall (Left-90)
6.0
6.0
2.667
96.0
0.34
0.22
2050-2 2
Window
Left Wall (Left-90)
5.0
5.0
0.8
20.0
0.29
0.20
5050
Window
Left Wall (Left-90)
---
--
1
25.0
0.29
0.20
2020
Left Wall (Left-90)
-
-
1
4.0
0.29
0.20
4Window
3060-2
Window
Rear Wall 2 (Back-180)
--
--
i1
36.0
0.29
0.20
6060
Window
Rear Wall 2 (Back-180)
3.0
3.0
1 4
36.0
0.29
0.20
3030-2
Window
Rear Wall 2 (Back-180)
---I
-
1
18.0
0.29
0.20
3060
Window
Rear Wall 2 (Back-180)
®` 3.0
3.0
2
18.0
0.29
0.20
9080 dr
Window
Rear Wall 2 (Back-180)
8.0
8.0
1.125
72.0
0.34
0.22
3060-2 2
Window
Right Wall 2 (Right-270)
---
----
1
36.0
0.29
0.20
3030-2 2
Window
Right Wall 2 (Right-270)
--
- --
1
18.0
0.29
0.20
3060-2 3
Window
Right Wall 2 (Right-270)
- -
---
1
36.0
0.29
0.20
20402
Window
Right Wall 2 (Right-270)
----
-
1
8.0
0.29
0.20
2650 V
I Window
Right Wall 2 (Right-270)
-
- --
1
12.5
0.29
0.20
DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
Right Wall 2
28.0
0.50
Door 16080
garage wall Front
128.0
1.00
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
` CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 6 of 11
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
12080 ddr
12
1
10
10
0
0
0
0
0
0
0
0
0
2050-2 2
0
0
0
0
0
0
0
0
0
0
0
0
0
6060
2
2
2
2
0
0
0
0
0
0
0
0
0
3060
2
2
j 2
2
0
0
0
0
0
0
0
10
0
9080 dr
12
1
10
10
0
0
0
0
0
0
0
0
0
..'* , " P en vir
R !:"' ^40 V t� 1 spa
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4 Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 7 of 11
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
Construction Name
Surface Type
Construction Type
Framing
Total Cavity R-value
Assembly Layers
Roofing: 10 PSF (Rooffile)
Above Deck insulation - no insulation -
2x4 Top Chord of
Roof Deck: Wood Siding/sheathing/decking
Roof Truss @ 24 in.
Cavity: - no insulation -
Attic Roof Cons
Attic Roofs
Wood Framed Ceiling
O.C.
Inside Finish: - select inside finish -
Attic Floor: - no attic floor -
Cavity. - no insulation -
Sheathinglnsulation - no sheathing/insul. -
R-0 Roof Attic
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
inside Finish: Gypsum Board
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity. R 19
Sheathing/Insulation: - no sheathing/insul. -
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Exterior Finish: Wood Siding/sheathing/decking
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity: R 13
Sheathing/insulation: - no sheathing/insul. -
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
Exterior Finish: Wood Siding/sheathing/decking
Attic Floor: - no attic floor -
Cavity: R 38
Sheathinglnsulation - no sheathing/insul. -
R-38 Roof Attic RB
Ceilings (below attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
Inside Finish: Gypsum Board
inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity: R 19
Sheathing/Insulation: - no sheathing/insul. -
R-19 Walll
Interior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 19
Other Side Finish: Gypsum Board
Inside Finish: Gypsum Board
Sheathing/Insulation: - no sheathing/insul. -
Cavity: - no insulation (vertical) -
no insulation
Sheathing/Insulation: - no sheathing/insul. -
Garage Ext Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
(vertical) -
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value& Depth
Carpeted Fraction
Heated
Slab
living
2042
223
None
0.8
No
Slab 2
Garage
542
83
None
0
No
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CalCERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 8 of 11
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation(Qll)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
ACH @ 50 Pa
Not Required
Not Required
Not Required
WATER HEATING SYSTEMS
01
02
03
04
Name
Distribution Type
Number of Heaters
Solar Fraction (%)
DHW Sys 1
Standard
1
0.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R-value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Instantaneous
0
0.95
185000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
ParallerPiping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1-hers-dhw
n/a
n/a
n/a
n/a
n/a
HVAC SYSTEMS
01
02
03
04
05
06
07
Heating System
Cooling System
Distribution
Floor Area
Name
System Type
Name Ducted
Name Ducted
System
Fan System
Served
HVAC System1
Other Heating and Cooling System
Heating Component 1
Yes
Cooling
Component 1
Yes
Air Distribution
System 1
HVAC Fan 1
2429
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4 Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 9 of 11
HVAC - COOLING SYSTEMS
01
02
03
04
05
Name
System Type
Efficiency
EER SEER
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning system
11.7
14
Cooling Component 1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
HVAC System1 SCSysRpt 1
Required
350
---
14.0
Verified
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
Supply Duct
Name
Type
Duct Leakage
Insulation R-value
Location
Return Duct
Bypass Duct
HERS Verification
Air Distribution System 1
Ducts located in unconditioned
Sealed and tested
6
Attic
Attic
None
Air Distribution
System 1-hers-dist
attic
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
Name
Duct Leakage Verification
Duct Leakage Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
Required
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
VerifiedFanWatt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4 Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Calculation Description: Title 24 Analysis Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 10 of 11
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
Name
IAQ CFM
IAQ Fan Type
IAQ Recovery Effectiveness(%)
HERS Verification
IAQ Fan
54
Exhaust
0
Required
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48
a` R CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Plan 4
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:00, Tue, Feb 02, 2016
Input File Name: 14024P4U.xml
CF1 R-PRF-01
Page 11 of 11
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Rudy Sains
Company:
Signature Date:
Heritage Energy Group
2016-02-03 09:08:19
Address:
CEA/HERS Certification Identification (If applicable):
470 Wald
City/State/Zip:
Phone:
Irvine, CA 92618
949-584-1052
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Dave Warren
Company:
Date Signed:
California West Communities
2016-02-03 09:12:45
Address:
License:
5927 Priestly Drive, Suite 103
N/A
City/State/Zip:
Phone:
Carlsbad, CA 92008
760-918-2824
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 216-N0043934A-000000000-0000 Registration Date/Time: 2016-02-03 09:12:45 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07232014-595c Report Generated at: 2016-02-02T12:07:48